1
|
Wnt16 Increases Bone-to-Implant Contact in an Osteopenic Rat Model by Increasing Proliferation and Regulating the Differentiation of Bone Marrow Stromal Cells. Ann Biomed Eng 2024; 52:1744-1762. [PMID: 38517621 PMCID: PMC11082046 DOI: 10.1007/s10439-024-03488-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 03/07/2024] [Indexed: 03/24/2024]
Abstract
Osseointegration is a complex biological cascade that regulates bone regeneration after implant placement. Implants possessing complex multiscale surface topographies augment this regenerative process through the regulation of bone marrow stromal cells (MSCs) that are in contact with the implant surface. One pathway regulating osteoblastic differentiation is Wnt signaling, and upregulation of non-canonical Wnts increases differentiation of MSCs on these titanium substrates. Wnt16 is a non-canonical Wnt shown to regulate bone morphology in mouse models. This study evaluated the role of Wnt16 during surface-mediated osteoblastic differentiation of MSCs in vitro and osseointegration in vivo. MSCs were cultured on Ti substrates with different surface properties and non-canonical Wnt expression was determined. Subsequently, MSCs were cultured on Ti substrates +/-Wnt16 (100 ng/mL) and anti-Wnt16 antibodies (2 μg/mL). Wnt16 expression was increased in cells grown on microrough surfaces that were processed to be hydrophilic and have nanoscale roughness. However, treatment MSCs on these surfaces with exogenous rhWnt16b increased total DNA content and osteoprotegerin production, but reduced osteoblastic differentiation and production of local factors necessary for osteogenesis. Addition of anti-Wnt16 antibodies blocked the inhibitor effects of Wnt16. The response to Wnt16 was likely independent of other osteogenic pathways like Wnt11-Wnt5a signaling and semaphorin 3a signaling. We used an established rat model of cortical and trabecular femoral bone impairment following botox injections (2 injections of 8 units/leg each, starting and maintenance doses) to assess Wnt16 effects on whole bone morphology and implant osseointegration. Wnt16 injections did not alter whole bone morphology significantly (BV/TV, cortical thickness, restoration of trabecular bone) but were effective at increasing cortical bone-to-implant contact during impaired osseointegration in the botox model. The mechanical quality of the increased bone was not sufficient to rescue the deleterious effects of botox. Clinically, these results are important to understand the interaction of cortical and trabecular bone during implant integration. They suggest a role for Wnt16 in modulating bone remodeling by reducing osteoclastic activity. Targeted strategies to temporally regulate Wnt16 after implant placement could be used to improve osseointegration by increasing the net pool of osteoprogenitor cells.
Collapse
|
2
|
Internal surface modification of additively manufactured macroporous TiAl6V4 biomimetic implants via a calciothermic reaction-based process and osteogenic in vivo responses. J Biomed Mater Res B Appl Biomater 2024; 112:e35322. [PMID: 37737450 DOI: 10.1002/jbm.b.35322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 08/02/2023] [Accepted: 08/16/2023] [Indexed: 09/23/2023]
Abstract
Three-dimensional macroporous titanium-aluminum-vanadium (TiAl6V4) implants produced by additive manufacturing (AM) can be grit blasted (GB) to yield microtextured exterior surfaces, with additional micro/nano-scale surface features provided by subsequent acid etching (AE). However, the line-of-sight nature of GB causes the topography of exterior GB + AE-modified surfaces to differ from internal GB-inaccessible surfaces. Previous in vitro studies using dense TiAl6V4 substrates indicated that a nonline-of-sight, calciothermic-reaction (CaR)-based process provided homogeneous osteogenic nanotextures on GB + AE surfaces, suggesting it could be used to achieve a homogeneous nanotopography on external and internal surfaces of macroporous AM constructs. Macroporous TiAl6V4 (3D) constructs were produced by direct laser melting and modified by GB + AE, with the CaR process then applied to 50% of constructs (3DCaR). The CaR process yielded nanoporous/nanorough internal surfaces throughout the macroporous constructs. Skeletally mature, male Sprague-Dawley rats were implanted with these constructs using a cranial on-lay model. Prior to implantation, a Cu++-free click hydrogel was applied to half of the constructs (3D + H, 3DCaR + H) to act as a challenge to osseointegration. Osseointegration was compared between the four implant groups (3D, 3DCaR, 3D + H, 3DCaR + H) at 4w. 3D + H implants exhibited lower bone volume (BV) and percent bone ingrowth (%BI) than the 3D implants. In contrast, osseointegrated 3DCaR + H implants had similar BV and %BI as the 3DCaR implants. Implant pull-off forces correlated with these results. In vitro analyses indicated that human bone marrow stromal cells (MSCs) exhibited enhanced production of osteoblast differentiation markers and factors associated with osteogenesis when grown on CaR-modified 3D substrates relative to control (TCPS) substrates. This work confirms that the CaR process provides osteogenic nanotextures on internal surfaces of macroporous 3D implants, and suggests that CaR-modified surfaces can promote osseointegration in cases where osteogenesis is impaired.
Collapse
|
3
|
Bone marrow stromal cells are sensitive to discrete surface alterations in build and post-build modifications of bioinspired Ti6Al4V 3D-printed in vitro testing constructs. J Biomed Mater Res B Appl Biomater 2023; 111:829-845. [PMID: 36372947 DOI: 10.1002/jbm.b.35194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 10/13/2022] [Accepted: 10/29/2022] [Indexed: 11/16/2022]
Abstract
Current standards in bone-facing implant fabrication by metal 3D (M3D) printing require post-manufacturing modifications to create distinct surface properties and create implant microenvironments that promote osseointegration. However, the biological consequences of build parameters and surface modifications are not well understood. This study evaluated the relative contributions of build parameters and post-manufacturing modification techniques to cell responses that impact osseointegration in vivo. Biomimetic testing constructs were created by using a M3D printer with standard titanium-aluminum-vanadium (Ti6Al4V) print parameters. These constructs were treated by either grit-blasting and acid-etching (GB + AE) or GB + AE followed by hot isostatic pressure (HIP) (GB + AE, HIP). Next, nine constructs were created by using a M3D printer with three build parameters: (1) standard, (2) increased hatch spacing, and (3) no infill, and additional contour trace. Each build type was further processed by either GB + AE, or HIP, or a combination of HIP treatment followed by GB + AE (GB + AE, HIP). Resulting constructs were assessed by SEM, micro-CT, optical profilometry, XPS, and mechanical compression. Cellular response was determined by culturing human bone marrow stromal cells (MSCs) for 7 days. Surface topography differed depending on processing method; HIP created micro-/nano-ridge like structures and GB + AE created micro-pits and nano-scale texture. Micro-CT showed decreases in closed pore number and closed porosity after HIP treatment in the third build parameter constructs. Compressive moduli were similar for all constructs. All constructs exhibited ability to differentiate MSCs into osteoblasts. MSCs responded best to micro-/nano-structures created by final post-processing by GB + AE, increasing OCN, OPG, VEGFA, latent TGFβ1, IL4, and IL10. Collectively these data demonstrate that M3D-printed constructs can be readily manufactured with distinct architectures based on the print parameters and post-build modifications. MSCs are sensitive to discrete surface topographical differences that may not show up in qualitative assessments of surface properties and respond by altering local factor production. These factors are vital for osseointegration after implant insertion, especially in patients with compromised bone qualities.
Collapse
|
4
|
Bone marrow stromal cells generate an osteoinductive microenvironment when cultured on titanium-aluminum-vanadium substrates with biomimetic multiscale surface roughness. Biomed Mater 2023; 18. [PMID: 36827708 PMCID: PMC9993812 DOI: 10.1088/1748-605x/acbf15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 02/24/2023] [Indexed: 02/26/2023]
Abstract
Osseointegration of titanium-based implants possessing complex macroscale/microscale/mesoscale/nanoscale (multiscale) topographies support a direct and functional connection with native bone tissue by promoting recruitment, attachment and osteoblastic differentiation of bone marrow stromal cells (MSCs). Recent studies show that the MSCs on these surfaces produce factors, including bone morphogenetic protein 2 (BMP2) that can cause MSCs not on the surface to undergo osteoblast differentiation, suggesting they may produce an osteogenic environmentin vivo. This study examined if soluble factors produced by MSCs in contact with titanium-aluminum-vanadium (Ti6Al4V) implants possessing a complex multiscale biomimetic topography are able to induce osteogenesis ectopically. Ti6Al4V disks were grit-blasted and acid-etched to create surfaces possessing macroscale and microscale roughness (MM), micro/meso/nanoscale topography (MN), and macro/micro/meso/nanoscale topography (MMNTM). Polyether-ether-ketone (PEEK) disks were also fabricated by machining to medical-grade specifications. Surface properties were assessed by scanning electron microscopy, contact angle, optical profilometry, and x-ray photoelectron spectroscopy. MSCs were cultured in growth media (GM). Proteins and local factors in their conditioned media (CM) were measured on days 4, 8, 10 and 14: osteocalcin, osteopontin, osteoprotegerin, BMP2, BMP4, and cytokines interleukins 6, 4 and 10 (IL6, IL4, and IL10). CM was collected from D14 MSCs on MMNTMand tissue culture polystyrene (TCPS) and lyophilized. Gel capsules containing active demineralized bone matrix (DBM), heat-inactivated DBM (iDBM), and iDBM + MMN-GM were implanted bilaterally in the gastrocnemius of athymic nude mice (N= 8 capsules/group). Controls included iDBM + GM; iDBM + TCPS-CM from D5 to D10 MSCs; iDBM + MMN-CM from D5 to D10; and iDBM + rhBMP2 (R&D Systems) at a concentration similar to D5-D10 production of MSCs on MMNTMsurfaces. Legs were harvested at 35D. Bone formation was assessed by micro computed tomography and histomorphometry (hematoxylin and eosin staining) with the histology scored according to ASTM 2529-13. DNA was greatest on PEEK at all time points; DNA was lowest on MN at early time points, but increased with time. Cells on PEEK exhibited small changes in differentiation with reduced production of BMP2. Osteoblast differentiation was greatest on the MN and MMNTM, reflecting increased production of BMP2 and BMP4. Pro-regenerative cytokines IL4 and IL10 were increased on Ti-based surfaces; IL6 was reduced compared to PEEK. None of the media from TCPS cultures was osteoinductive. However, MMN-CM exhibited increased bone formation compared to iDBM and iDBM + rhBMP2. Furthermore, exogenous rhBMP2 alone, at the concentration found in MMN-CM collected from D5 to D10 cultures, failed to induce new bone, indicating that other factors in the CM play a critical role in that osteoinductive microenvironment. MSCs cultured on MMNTMTi6Al4V surfaces differentiate and produce an increase in local factors, including BMP2, and the CM from these cultures can induce ectopic bone formation compared to control groups, indicating that the increased bone formation arises from the local response by MSCs to a biomimetic, multiscale surface topography.
Collapse
|
5
|
Osseointegration of Titanium Implants in a Botox-Induced Muscle Paralysis Rat Model Is Sensitive to Surface Topography and Semaphorin 3A Treatment. Biomimetics (Basel) 2023; 8:biomimetics8010093. [PMID: 36975323 PMCID: PMC10046785 DOI: 10.3390/biomimetics8010093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/06/2023] [Accepted: 02/22/2023] [Indexed: 03/03/2023] Open
Abstract
Reduced skeletal loading associated with many conditions, such as neuromuscular injuries, can lead to bone fragility and may threaten the success of implant therapy. Our group has developed a botulinum toxin A (botox) injection model to imitate disease-reduced skeletal loading and reported that botox dramatically impaired the bone formation and osseointegration of titanium implants. Semaphorin 3A (sema3A) is an osteoprotective factor that increases bone formation and inhibits bone resorption, indicating its potential therapeutic role in improving osseointegration in vivo. We first evaluated the sema3A effect on whole bone morphology following botox injections by delivering sema3A via injection. We then evaluated the sema3A effect on the osseointegration of titanium implants with two different surface topographies by delivering sema3A to cortical bone defect sites prepared for implant insertion and above the implants after insertion using a copper-free click hydrogel that polymerizes rapidly in situ. Implants had hydrophobic smooth surfaces (PT) or multiscale biomimetic micro/nano topography (SLAnano). Sema3A rescued the botox-impaired bone formation. Furthermore, biomimetic Ti implants improved the bone-to-implant contact (BIC) and mechanical properties of the integrated bone in the botox-treated rats, which sema3A enhanced. This study demonstrated the value of biomimetic approaches combining multiscale topography and biologics in improving the clinical outcomes of implant therapy.
Collapse
|
6
|
Tailoring of TiAl6V4 Surface Nanostructure for Enhanced In Vitro Osteoblast Response via Gas/Solid (Non-Line-of-Sight) Oxidation/Reduction Reactions. Biomimetics (Basel) 2022; 7:biomimetics7030117. [PMID: 36134921 PMCID: PMC9496476 DOI: 10.3390/biomimetics7030117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/12/2022] [Accepted: 08/17/2022] [Indexed: 11/26/2022] Open
Abstract
An aging global population is accelerating the need for better, longer-lasting orthopaedic and dental implants. Additive manufacturing can provide patient-specific, titanium-alloy-based implants with tailored, three-dimensional, bone-like architecture. Studies using two-dimensional substrates have demonstrated that osteoblastic differentiation of bone marrow stromal cells (MSCs) is enhanced on surfaces possessing hierarchical macro/micro/nano-scale roughness that mimics the topography of osteoclast resorption pits on the bone surface. Conventional machined implants with these surfaces exhibit successful osseointegration, but the complex architectures produced by 3D printing make consistent nanoscale surface texturing difficult to achieve, and current line-of-sight methods used to roughen titanium alloy surfaces cannot reach all internal surfaces. Here, we demonstrate a new, non-line-of-sight, gas/solid-reaction-based process capable of generating well-controlled nanotopographies on all open (gas-exposed) surfaces of titanium alloy implants. Dense 3D-printed titanium-aluminum-vanadium (TiAl6V4) substrates were used to evaluate the evolution of surface nanostructure for development of this process. Substrates were either polished to be smooth (for easier evaluation of surface nanostructure evolution) or grit-blasted and acid-etched to present a microrough biomimetic topography. An ultrathin (90 ± 16 nm) conformal, titania-based surface layer was first formed by thermal oxidation (600 °C, 6 h, air). A calciothermic reduction (CaR) reaction (700 °C, 1 h) was then used to convert the surface titania (TiO2) into thin layers of calcia (CaO, 77 ± 16 nm) and titanium (Ti, 51 ± 20 nm). Selective dissolution of the CaO layer (3 M acetic acid, 40 min) then yielded a thin nanoporous/nanorough Ti-based surface layer. The changes in surface nanostructure/chemistry after each step were confirmed by scanning and transmission electron microscopies with energy-dispersive X-ray analysis, X-ray diffraction, selected area electron diffraction, atomic force microscopy, and mass change analyses. In vitro studies indicated that human MSCs on CaR-modified microrough surfaces exhibited increased protein expression associated with osteoblast differentiation and promoted osteogenesis compared to unmodified microrough surfaces (increases of 387% in osteopontin, 210% in osteocalcin, 282% in bone morphogenic protein 2, 150% in bone morphogenic protein 4, 265% in osteoprotegerin, and 191% in vascular endothelial growth factor). This work suggests that this CaR-based technique can provide biomimetic topography on all biologically facing surfaces of complex, porous, additively manufactured TiAl6V4 implants.
Collapse
|
7
|
Hydrophilic implants generated using a low-cost dielectric barrier discharge plasma device at the time of placement exhibit increased osseointegration in an animal pre-clinical study: An effect that is sex-dependent. Dent Mater 2022; 38:632-645. [PMID: 35184898 PMCID: PMC9123943 DOI: 10.1016/j.dental.2022.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 02/08/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Increased wettability of titanium and titanium alloy surfaces due to processing and storage methods increases osteoprogenitor cell differentiation and osseointegration compared to microroughness alone. Implants that are exposed to air have a hydrophobic surface due to adsorption of atmospheric hydrocarbons, which can limit overall implant success. Dielectric barrier discharge plasma (DBD) is one method to increase surface hydrophilicity. Although current DBD methods yield a hydrophilic surface, adsorbed hydrocarbons rapidly restore hydrophobicity. We demonstrated that application of DBD to implants previously packaged in a vacuum, generates a hydrophilic surface that supports osteoblastic differentiation in vitro and this can be done immediately prior to use. In the present study, we tested the hypothesis that DBD treatment to alter surface wettability at the time of implant placement will improve osseointegration in vivo. MATERIALS AND METHODS Twenty male and sixteen female rabbits were used in a preclinical trans-axial femur model of osseointegration. Control and DBD treatment implants were inserted randomized per hind limb in each rabbit (1 implant/hind-limb). At 6 weeks post-surgery, bone-to-implant contact, adjacent bone volume, and torque to failure were assessed by micro-CT, calcified histology, and mechanical testing. RESULTS DBD plasma treatment of vacuum-sealed implants increased surface wettability and did not change surface chemistry or roughness. Peak torque and torsional energy, and bone-to-implant contact increased with DBD treatment in males. In contrast, female rabbits showed increased osseointegration equal to DBD treated male implants regardless of DBD plasma treatment. CONCLUSION DBD treatment is an effective method to enhance osseointegration by increasing surface wettability; however, this response is sex dependent. In healthy female patients, DBD treatment may not be necessary but in older patients or patients with compromised bone, this treatment could be an effective measure to ensure implant success.
Collapse
|
8
|
Growth factors produced by bone marrow stromal cells on nanoroughened titanium-aluminum-vanadium surfaces program distal MSCs into osteoblasts via BMP2 signaling. J Orthop Res 2021; 39:1908-1920. [PMID: 33002223 PMCID: PMC8012402 DOI: 10.1002/jor.24869] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 09/21/2020] [Accepted: 09/29/2020] [Indexed: 02/04/2023]
Abstract
Statement of Clinical Significance: There remains the need to develop materials and surfaces that can increase the rate of implant osseointegration. Though osteoanabolic agents, like bone morphogenetic protein (BMP), can provide signaling for osteogenesis, the appropriate design of implants can also produce an innate cellular response that may reduce or eliminate the need to use additional agents to stimulate bone formation. Studies show that titanium implant surfaces that mimic the physical properties of osteoclast resorption pits regulate cellular responses of bone marrow stromal cells (MSCs) by altering cell morphology, transcriptomes, and local factor production to increase their differentiation into osteoblasts without osteogenic media supplements required for differentiation of MSCs on tissue culture polystyrene (TCPS). The goal of this study was to determine how cells in contact with biomimetic implant surfaces regulate the microenvironment around these surfaces in vitro. Two different approaches were used. First, unidirectional signaling was assessed by treating human MSCs grown on TCPS with conditioned media from MSC cultures grown on Ti6Al4V biomimetic surfaces. In the second set of studies, bidirectional signaling was assessed by coculturing MSCs grown on mesh inserts that were placed into culture wells in which MSCs were grown on the biomimetic Ti6Al4V substrates. The results show that biomimetic Ti6Al4V surface properties induce MSCs to produce factors within 7 days of culture that stimulate MSCs not in contact with the surface to exhibit an osteoblast phenotype via endogenous BMP2 acting in a paracrine signaling manner.
Collapse
|
9
|
Benchtop plasma treatment of titanium surfaces enhances cell response. Dent Mater 2021; 37:690-700. [PMID: 33589272 DOI: 10.1016/j.dental.2021.01.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 01/20/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE Modifications to implant surface properties, including topography, chemistry, and wettability, alter immune response, osteoblast differentiation of bone marrow stromal cells (MSCs), and implant integration in vivo. Dielectric barrier discharge (DBD) plasma treatment has been used to sterilize surfaces and remove adsorbed carbon, improving wettability. However, unless it is used immediately prior to placement, ambient atmospheric hydrocarbons rapidly adhere to the surface, thereby reducing its hydrophilicity. Moreover, this method is not practical in many clinical settings. The aim of this study was to evaluate the effectiveness of an on-site benchtop modification technique for implants at time of placement, consisting of a DBD plasma that is used to sterilize implants that are pre-packaged in a vacuum. Effects of the plasma-treatment on implant surface properties and cellular response of MSCs and osteoblasts were assessed in vitro. METHODS Titanium-aluminum-vanadium implant surfaces were grit-blasted (GB) or grit-blasted and acid-etched (AE), and packaged under vacuum. AE surfaces were also plasma-treated using the benchtop device (GB + AE) and then removed from the vacuum. GB surface morphology was altered with AE but AE microroughness was not changed with the plasma-treatment. Plasma-treatment increased the surface wettability, but did not alter surface atomic concentrations of titanium, oxygen, or carbon. RESULTS MSCs and osteoblast-like cells (MG63 s) produced increased concentrations of osteocalcin, osteopontin, and osteoprotegerin after plasma-treatment of AE surfaces compared to non-plasma-treated AE surfaces; production of IL6 was reduced and IL10 was. Aging GB + AE surfaces for 7 days after plasma-treatment but still in the vacuum environment reduced the effectiveness of plasma on cellular response. SIGNIFICANCE Overall, these data suggest that application of benchtop plasma at the time of implant placement can alter the surface free energy of an implant surface without modifying surface chemical composition and enhance the differentiation and activity of MSCs and osteoblasts that are in contact with these implant surfaces.
Collapse
|
10
|
Regulation of mesenchymal stem cell differentiation on microstructured titanium surfaces by semaphorin 3A. Bone 2020; 134:115260. [PMID: 32028017 PMCID: PMC7749709 DOI: 10.1016/j.bone.2020.115260] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 01/30/2020] [Accepted: 02/01/2020] [Indexed: 10/25/2022]
Abstract
Peri-implant bone formation depends on the ability of mesenchymal stem cells (MSCs) to colonize implant surfaces and differentiate into osteoblasts, but the precise mechanisms controlling this process remain unclear. In vitro, MSCs undergo osteoblastic differentiation on microstructured titanium (Ti) surfaces in the absence of exogenous media supplements and produce factors that promote osteogenesis while regulating osteoclast activity, including semaphorins. The goal of this study was to evaluate the role of semaphorin 3A (Sema3A) on surface-mediated osteoblastic differentiation and determine the hierarchy of this signaling cascade. Human MSCs were cultured on 15 mm grade 2 smooth (pretreatment, PT), hydrophobic-microrough (sand blasted/acid etched, SLA), hydrophilic-microrough Ti (mSLA) (Institut Straumann AG, Basel, Switzerland), or tissue culture polystyrene (TCPS). Expression of SEMA3A family proteins increased after 7 days of culture, and the increased expression in response to microstructured Ti was dependent on recognition of the surface by integrin α2β1. Exogenous Sema3A increased differentiation whereas differentiation was decreased in cells treated with a Sema3A antibody. Furthermore, Sema3A influenced the production of osteoprotegerin and osteopontin suggesting it as an important local regulator of bone remodeling. Inhibition of Wnt3A and Wnt5A revealed that activation of Sema3A occurs downstream of Wnt5A and may facilitate the translocation of β-catenin bypassing the canonical Wnt3A initiating signal associated with osteoblastic differentiation. Furthermore, chemical inhibition of calmodulin (CaM), Ca2+/calmodulin-dependent protein kinase (CaMKII), phospholipase A2 (PLA2), protein kinase C (PKC), and BMP receptors suggest that Sema3A could serve as a feedback mechanism for both Wnt5A and BMP2. Here, we show novel roles for Sema3A family proteins in the surface-dependent modulation of MSCs as well as important interactions with pathways known to be associated with osteoblastic differentiation. Moreover, their effects on bone remodeling markers have significant implications for peri-implant bone remodeling and downstream modulation of osteoclastic activity. These results suggest that Sema3A aids in peri-implant bone formation through regulation on multiple stages of osseointegration, making it a potential target to promote osseointegration in patients with compromised bone remodeling.
Collapse
|
11
|
Hot isostatic pressure treatment of 3D printed Ti6Al4V alters surface modifications and cellular response. J Biomed Mater Res B Appl Biomater 2020; 108:1262-1273. [PMID: 31469519 PMCID: PMC7048629 DOI: 10.1002/jbm.b.34474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 06/26/2019] [Accepted: 08/06/2019] [Indexed: 11/05/2022]
Abstract
Additive manufacturing can be used to create personalized orthopedic and dental implants with varying geometries and porosities meant to mimic morphological properties of bone. These qualities can alleviate stress shielding and increase osseointegration through bone ingrowth, but at the expense of reduced fatigue properties compared to machined implants, and potential for loose build particle erosion. Hot isostatic pressure (HIP) treatment is used to increase fatigue resistance; implant surface treatments like grit-blasting and acid-etching create microroughness and reduce the presence of loose particles. However, it is not known how HIP treatment affects surface treatments and osseointegration of the implant to bone. We manufactured two titanium-aluminum-vanadium constructs, one with simple through-and-through porosity and one possessing complex trabecular bone-like porosity. We observed HIP treatment varied in effect and was dependent on architecture. Micro/meso/nano surface properties generated by grit-blasting and acid-etching were altered on biomimetic HIP-treated constructs. Human mesenchymal stem cells (MSCs) were cultured on constructs fabricated +/- HIP and subsequently surface-treated. MSCs were sensitive to 3D-architecture, exhibiting greater osteogenic differentiation on constructs with complex trabecular bone-like porosity. HIP-treatment did not alter the osteogenic response of MSCs to these constructs. Thus, HIP may provide mechanical and biological advantages during implant osseointegration and function.
Collapse
|
12
|
VEGF-A regulates angiogenesis during osseointegration of Ti implants via paracrine/autocrine regulation of osteoblast response to hierarchical microstructure of the surface. J Biomed Mater Res A 2018; 107:423-433. [PMID: 30461195 DOI: 10.1002/jbm.a.36559] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 09/24/2018] [Accepted: 10/08/2018] [Indexed: 12/22/2022]
Abstract
Establishment of a patent vasculature at the bone-implant interface plays a significant role in determining overall success of orthopedic and dental implants. Osteoblasts produce vascular endothelial growth factor-A (VEGF-A), an important regulator of angiogenesis during bone formation and healing, and the amount secreted is sensitive to titanium (Ti) surface microtopography and surface energy. The purpose of this study was to determine if surface properties modulate cellular response to VEGF-A. MG63 osteoblast-like cells were transfected with shRNA targeting VEGF-A at >80% knockdown. Cells stably silenced for VEGF-A secreted reduced levels of osteocalcin, osteoprotegerin, FGF-2, and angiopoietin-1 when cultured on grit-blasted/acid-etched (SLA) and hydrophilic SLA (modSLA) Ti surfaces and conditioned media from these cultures caused reduced angiogenesis in an endothelial tubule formation assay. Treatment of MG63 cells with 20 ng/mL rhVEGF-A165 rescued production in silenced cells and increased production of osteocalcin, osteoprotegerin, FGF-2, and angiopoietin-1, with greatest effects on control cells cultured on modSLA. Addition of a neutralization antibody against VEGF receptor 2 (VEGFR2; Flk-1) resulted in a significant increase in VEGF-A production. Overall, this study indicates that VEGF-A has two roles in osseointegration: enhanced angiogenesis and an autocrine/paracrine role in maturation of osteoblast-like cells in response to Ti surface properties. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 423-433, 2019.
Collapse
|
13
|
Implementation of the North Carolina HIV Bridge Counseling Program to Facilitate Linkage and Reengagement in Care for Individuals Infected with HIV/AIDS. N C Med J 2018; 79:210-217. [PMID: 29991608 DOI: 10.18043/ncm.79.4.210] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Statewide interventions are critical to meeting the goals of the National HIV/AIDS Strategy in this country. In 2012, the North Carolina Division of Public Health developed the North Carolina State Bridge Counselor program to improve linkage to and reengagement in care for newly diagnosed persons and persons living with HIV who were out-of-care.METHODS We reviewed the planning process for the North Carolina State Bridge Counselor program, which involved a review of existing strengths-based counseling models for persons living with HIV, implementation of these models, and communication strategies with other providers. State bridge counselor responsibilities were delineated from the role of disease intervention specialists while retaining the fieldwork capability of disease intervention specialists to conduct outreach and provide services for persons living with HIV throughout the state.RESULTS Program implementation required extensive planning with stakeholders, incorporation of strengths-based counseling models, development of performance standards, and utilization of CAREWare, an HIV care software program to document referrals and data-sharing between state bridge counselors and clinics. By the end of 2014, state bridge counselor services were provided to approximately 60 of the 400 persons living with HIV (15%) who are diagnosed each quarter in North Carolina, with increasing utilization of the program.LIMITATIONS We assessed the development of this intervention specific to the North Carolina Division of Public Health, which may limit its generalizability. However, the State Bridge Counselor program was implemented in both urban and rural areas throughout the state, which increases its applicability to different public health programs throughout the country.CONCLUSION We demonstrated that a statewide State Bridge Counselor program for linkage and reengagement activities can be implemented by leveraging existing infrastructures, electronic medical records, HIV care networks, and fieldwork activities.
Collapse
|
14
|
Human osteoblasts exhibit sexual dimorphism in their response to estrogen on microstructured titanium surfaces. Biol Sex Differ 2018; 9:30. [PMID: 29970177 PMCID: PMC6029108 DOI: 10.1186/s13293-018-0190-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/25/2018] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Osseointegration is dependent on the implant surface, surrounding bone quality, and the systemic host environment, which can differ in male and female patients. Titanium (Ti) implants with microstructured surfaces exhibit greater pullout strength when compared to smooth-surfaced implants and exhibit enhanced osteogenic cellular responses in vitro. Previous studies showed that 1α,25-dihydroxyvitamin D3 [1α,25(OH)2D3] has a greater effect on rat osteoblast differentiation on microstructured Ti compared to smooth Ti surfaces and tissue culture polystyrene (TCPS). The stimulatory effect of 17β-estradiol (E2) on differentiation is observed in female osteoblasts on micro-rough Ti, but it is not known if male osteoblasts behave similarly in response to E2 and microtopography. This study assessed whether human male and female osteoblasts exhibit sex-specific differences in response to E2 and 1α,25(OH)2D3 when cultured on microstructured Ti surfaces. METHODS Osteoblasts from three male and three female human donors were cultured on Ti discs with varying surface profiles: a smooth pretreatment (PT), a coarse grit-blasted/acid-etched (SLA), and an SLA surface having undergone modification in a nitrogen environment and stored in saline to maintain hydrophilicity (modSLA). Cells cultured on these surfaces were treated with E2 or 1α,25(OH)2D3. RESULTS Male and female human osteoblasts responded similarly to microstructure although there were donor-specific differences; cell number decreased, and osteocalcin (OCN), osteoprotegerin (OPG), and latent and active transforming growth factor 1 increased on SLA and modSLA compared to TCPS. Female osteoblasts had higher alkaline phosphatase activity and OCN production than male counterparts but produced less OPG. Both sexes responded similarly to 1α,25(OH)2D3. E2 treatment reduced cell number and increased osteoblast differentiation and factor production only in female cells. CONCLUSIONS Male and female human osteoblasts respond similarly to microstructure and 1α,25(OH)2D3 but exhibit sexual dimorphism in substrate-dependent responses to E2. E2 affected female osteoblasts, suggesting that signaling is sex-specific and surface-dependent. Donor osteoblasts varied in response, demonstrating the need to test multiple donors when examining human samples. Understanding how male and female cells respond to orthopedic biomaterials will enable greater predictability post-implantation as well as therapies that are more patient-specific.
Collapse
|
15
|
Role of Wnt11 during Osteogenic Differentiation of Human Mesenchymal Stem Cells on Microstructured Titanium Surfaces. Sci Rep 2018; 8:8588. [PMID: 29872092 PMCID: PMC5988747 DOI: 10.1038/s41598-018-26901-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Accepted: 05/18/2018] [Indexed: 01/09/2023] Open
Abstract
Successful osseointegration of an endosseous implant involves migration and differentiation of mesenchymal stem cells (MSCs) on the implant surface. Micro-structured, hydrophilic titanium surfaces direct MSCs to undergo osteoblastic differentiation in vitro, in the absence of media additives commonly used in cultures grown on tissue culture polystyrene (TCPS). This process involves non-canonical Wnt5a, in contrast to canonical Wnt3a typically credited with osteoblastic differentiation on TCPS. Wnt proteins have been implicated in morphological development and tissue patterning, suggesting that additional Wnts may participate. Here, we demonstrate that Wnt11 is a mediator of osteoblast commitment of MSCs, and increases in a surface-roughness dependent manner. Experiments using cells silenced for Wnt11 indicate that cross-talk between Wnt5a and Wnt11 occurs. Wnt11 potentially acts upstream to Wnt5a, increasing Wnt5a expression and factors associated with osteogenesis. Thus, Wnt11 contributes to peri-implant bone formation distal to the implant surface through a heavily regulated signaling cascade of autocrine/paracrine proteins.
Collapse
|
16
|
Regulation of osteoclasts by osteoblast lineage cells depends on titanium implant surface properties. Acta Biomater 2018; 68:296-307. [PMID: 29292169 PMCID: PMC5803380 DOI: 10.1016/j.actbio.2017.12.039] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 11/29/2017] [Accepted: 12/22/2017] [Indexed: 01/16/2023]
Abstract
A critical stage during osseointegration of a titanium (Ti) implant is primary bone remodeling, which involves cross talk among osteoclast precursors, osteoclasts, mesenchymal stem cells (MSCs), and osteoblasts. This phase couples the processes of bone formation and resorption. During remodeling, osteoclasts produce factors capable of regulating MSC migration and osteogenesis. Furthermore, they degrade primary bone, creating a foundation with a specific chemistry, stiffness, and morphology for osteoblasts to synthesize and calcify their matrix. MSCs and osteoblasts receiving cues from the implant surface produce factors capable of regulating osteoclasts in order to promote net new bone formation. The purpose of this study was to determine the effects Ti implant surfaces have on bone remodeling. Human MSCs and normal human osteoblasts (NHOsts) were cultured separately on 15 mm grade 2 smooth PT, hydrophobic-microrough SLA, hydrophilic-microrough Ti (mSLA) (Institut Straumann AG, Basel, Switzerland), or tissue culture polystyrene (TCPS). After 7d, conditioned media from surface cultures were used to treat human osteoclasts for 2d. Activity was measured by fluorescence of released collagen followed by mRNA quantification. This study demonstrates that MSC and NHOst cultures are able to suppress osteoclast activity in a surface dependent manner and osteoclast mRNA levels are selectively regulated by surface treatments. The substrate-dependent regulatory effect was mitigated when MSCs were silenced for integrin subunits and when conditioned media were denatured. These results indicate that MSCs and NHOsts regulate at least two aspects of remodeling: reduced fusion of new osteoclasts and reduced activity of existing osteoclasts. STATEMENT OF SIGNIFICANCE In this study, we developed a novel in vitro model to study how microstructured and hydrophilic titanium implants impact bone remodeling for dental and orthopaedic applications. Our approach intersects biomaterials and systems physiology, revealing for the first time that implant surface properties are capable of regulating the communication among the cells involved in remodeling of primary bone during osseointegration. We believe that the basic research presented in our manuscript will provide important knowledge in our understanding of factors that impact implant success. Furthermore, it provides a solid foundation for the development of materials that enable rapid osseointegration and earlier loading times for implants in bone that has been compromised by trauma or disease.
Collapse
|
17
|
Early hospital discharge of infants born to group B streptococci-positive mothers: a decision analysis. BJOG 2012; 119:439-48. [PMID: 22251453 DOI: 10.1111/j.1471-0528.2011.03249.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To compare the cost-effectiveness of an additional 24-hour inpatient observation for asymptomatic term neonates born to group B streptococcus (GBS)-colonised mothers with adequate intrapartum antibiotic prophylaxis (IAP) after an initial 24-hour in-hospital observation. DESIGN Cost-effectiveness analysis from a societal perspective. SETTING United States. POPULATION Asymptomatic term neonates born to GBS-colonised mothers with IAP after an initial 24-hour in-hospital observation. METHODS Monte Carlo simulation for a decision tree model incorporating the following chance events: development of GBS sepsis during the second 24 hours of life, development of GBS sepsis between 48 hours and 7 days of life, prompt versus delayed treatment for sepsis, neonatal mortality and long-term health sequelae. MAIN OUTCOME MEASURES Expected cost and quality-adjusted life years (QALYs), Incremental cost-effectiveness ratio (ICER). RESULTS Delayed, versus early, hospital discharge results in similar mean expected QALYs, but substantially higher expected cost. The mean difference in QALY is 0.00016 (95% CI 0.00005-0.00040), whereas the mean difference in cost is $1170.96 (95% CI $750.13-1584.32). The ICER is estimated to be $9,771,520.87 per QALY (95% CI $2,573,139.89-24,407,017.82). The proportion of early-onset GBS that develops during the second 24 hours of life, the cost of 24 hours of inpatient observation, and the probability of long-term sequelae following prompt versus delayed treatment play important roles in determining the cost-effectiveness of delayed hospital discharge. CONCLUSION Cost-effectiveness analysis suggests that with adequate IAP, discharging asymptomatic term neonates to home after 24 hours is the preferred approach compared with 48 hours inpatient observation.
Collapse
|
18
|
Residency after 40 is about 40 times tougher. MEDICAL ECONOMICS 1991; 68:140-2, 147-8, 150. [PMID: 10110085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
19
|
Lung transplantation: an emerging technology. Tex Med 1988; 84:61-7. [PMID: 3064350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
20
|
Elevated concentrations of soluble interleukin-2 receptors in serum samples and bronchoalveolar lavage fluids in active sarcoidosis. THE AMERICAN REVIEW OF RESPIRATORY DISEASE 1988; 137:759-64. [PMID: 3128148 DOI: 10.1164/ajrccm/137.4.759] [Citation(s) in RCA: 86] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Sarcoidosis is a granulomatous disorder of unknown cause characterized by activation of T-lymphocytes. We here report the use of an enzyme-linked immunosorbent assay for the soluble interleukin-2 receptor (IL-2R) as a measure of T-cell activation in serum samples and bronchoalveolar lavage fluids in 15 patients with active sarcoidosis. The geometric mean (x divided by SEM) value for soluble IL-2R in serum samples from patients with sarcoidosis was 1,110 (x divided by 1.17) versus 224 (x divided by 1.08) U/ml for normal control subjects (p less than 0.001). Detectable levels of soluble IL-2R were present in bronchoalveolar lavage fluids from 10 of 15 patients with sarcoidosis versus only 2 of 36 normal control subjects (p less than 0.001). Levels of soluble IL-2R in serum samples from untreated patients with sarcoidosis correlated with 67gallium lung scanning scores (p less than 0.05) but not with serum angiotensin-converting enzyme concentrations or constituents of bronchoalveolar lavage. In 5 patients, the level of soluble IL-2R in serum samples fell from 1,499 (x divided by 1.20) to 476 (x divided by 1.58) U/ml (p less than 0.05) after 6 wk of successful treatment with corticosteroids, whereas the changes in soluble IL-2R in bronchoalveolar lavage fluids were more variable. These observations suggest that measurements of soluble IL-2R, particularly in serum samples, may reflect disease activity and be clinically useful in the management of patients with sarcoidosis.
Collapse
|
21
|
Elevated serum levels of soluble interleukin-2 receptors in active pulmonary sarcoidosis: relative specificity and association with hypercalcemia. SARCOIDOSIS 1987; 4:87-93. [PMID: 2821601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
We have previously reported serum elevations of the soluble form of the interleukin-2 receptor (IL-2R), a marker of T-cell activation, in sarcoidosis. In the present study, an enzyme-linked immunosorbent assay for soluble IL-2R was employed to compare sera from normal controls with those from patients with active sarcoidosis or idiopathic pulmonary fibrosis (IPF). Sera from patients with active sarcoidosis and parenchymal lung disease (radiographic Stages II or III) had geometric mean values for soluble IL-2R of 1975 units/ml compared to 640 units/ml for normal controls (p less than 0.001, Student's t-test). By contrast, soluble IL-2R levels were lower (989 units/ml, p less than 0.05 compared to normals) in patients with active sarcoidosis but no radiographic evidence for parenchymal disease (Stages 0 or I). Soluble IL-2R levels were not elevated in patients with inactive sarcoidosis. Three of the 4 sarcoidosis patients with the highest levels of soluble IL-2R also manifested hypercalcemia. While levels of soluble IL-2R were elevated for the group of patients with IPF (1171 units/ml, p less than 0.05 compared to normals), the striking elevations of soluble IL-2R noted in active sarcoidosis were not seen and there was greater overlap with normal values. We conclude that marked serum elevations of soluble IL-2R are more suggestive of active pulmonary sarcoidosis than IPF.
Collapse
|
22
|
Abstract
Recent in vitro susceptibility studies have shown that amikacin inhibits more than 90% of isolates of Nocardia. This study was designed to evaluate the effect of treatment with amikacin or sulfonamides on infection caused by Nocardia asteroides with the use of murine models. In an acute lethality model in which infection was induced by intraperitoneal injection, 13 (45%) of 29 mice that had been treated with amikacin survived, in comparison to zero of 39 untreated animals in the control group and one of 39 mice that had been treated with sulfadiazine (P less than 0.001 for amikacin). When infected with a strain of N. asteroides that was resistant to amikacin, all mice that were treated with amikacin and all untreated mice died. Drug therapy was also evaluated in a chronic infection model, in which abscesses were produced by an intraperitoneal injection of N. asteroides in saline. Treatment with either amikacin (P less than 0.001) or sulfonamide (P less than 0.02) for two to three weeks significantly increased the rate of resolution of these abscesses. These murine models demonstrate that amikacin has in vivo activity against Nocardia and may be potentially useful in the treatment of human disease.
Collapse
|