1
|
Migration Study of Dielectrophoretically Manipulated Red Blood Cells in Tapered Aluminium Microelectrode Array: A Pilot Study. MICROMACHINES 2023; 14:1625. [PMID: 37630162 PMCID: PMC10457829 DOI: 10.3390/mi14081625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/29/2023] [Accepted: 07/19/2023] [Indexed: 08/27/2023]
Abstract
Dielectrophoresis (DEP) is one of the microfluid-based techniques that can manipulate the red blood cells (RBC) for blood plasma separation, which is used in many medical screening/diagnosis applications. The tapered aluminium microelectrode array (TAMA) is fabricated for potential sensitivity enhancement of RBC manipulation in lateral and vertical directions. In this paper, the migration properties of dielectrophoretically manipulated RBC in TAMA platform are studied at different peak-to-peak voltage (Vpp) and duration supplied onto the microelectrodes. Positive DEP manipulation is conducted at 440 kHz with the RBC of 4.00 ± 0.2 µm average radius attracted to the higher electric field intensity regions, which are the microelectrodes. High percentage of RBC migration occurred at longer manipulation time and high electrode voltage. During DEP manipulation, the RBC are postulated to levitate upwards, experience the electro-orientation mechanism and form the pearl chains before migrating to the electrodes. The presence of external forces other than the dielectrophoretic force may also affect the migration response of RBC. The safe operating limit of 10 Vpp and manipulation duration of ≤50 s prevent RBC rupture while providing high migration percentage. It is crucial to define the safe working region for TAMA devices that manipulate small RBC volume (~10 µL).
Collapse
|
2
|
Dielectrophoresis microbial characterization and isolation of Staphylococcus aureus based on optimum crossover frequency. Electrophoresis 2023; 44:1220-1233. [PMID: 37259263 DOI: 10.1002/elps.202200276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 04/19/2023] [Accepted: 04/29/2023] [Indexed: 06/02/2023]
Abstract
Characterization of antibiotic-resistant bacteria is a significant concern that persists for the rapid classification and analysis of the bacteria. A technology that utilizes the manipulation of antibiotic-resistant bacteria is key to solving the significant threat of these pathogenic bacteria by rapid characterization profile. Dielectrophoresis (DEP) can differentiate between antibiotic-resistant and susceptible bacteria based on their physical structure and polarization properties. In this work, the DEP response of two Gram-positive bacteria, namely, Methicillin-resistant Staphylococcus aureus (MRSA) and Methicillin-susceptible S. aureus (MSSA), was investigated and simulated. The DEP characterization was experimentally observed on the bacteria influenced by oxacillin and vancomycin antibiotics. MSSA control without antibiotics has crossover frequencies (f x 0 ${f_{x0}}$ ) from 6 to 8 MHz, whereas MRSA control is from 2 to 3 MHz. Thef x 0 ${f_{x0}}$ changed when bacteria were exposed to the antibiotic. As for MSSA, thef x 0 ${f_{x0}}$ decreased to 3.35 MHz compared tof x 0 ${f_{x0}}$ MSSA control without antibiotics, MRSA,f x 0 ${f_{x0}}$ increased to 7 MHz when compared to MRSA control. The changes in the DEP response of MSSA and MRSA with and without antibiotics were theoretically proven using MyDEP and COMSOL simulation and experimentally based on the modification to the bacteria cell walls. Thus, the DEP response can be employed as a label-free detectable method to sense and differentiate between resistant and susceptible strains with different antibiotic profiles. The developed method can be implemented on a single platform to analyze and identify bacteria for rapid, scalable, and accurate characterization.
Collapse
|
3
|
Recent Approaches to the Modification of Collagen Biomatrix as a Corneal Biomatrix and Its Cellular Interaction. Polymers (Basel) 2023; 15:polym15071766. [PMID: 37050380 PMCID: PMC10097332 DOI: 10.3390/polym15071766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 03/21/2023] [Accepted: 03/30/2023] [Indexed: 04/05/2023] Open
Abstract
Over the last several decades, numerous modifications and advancements have been made to design the optimal corneal biomatrix for corneal epithelial cell (CECs) or limbal epithelial stem cell (LESC) carriers. However, researchers have yet to discover the ideal optimization strategies for corneal biomatrix design and its effects on cultured CECs or LESCs. This review discusses and summarizes recent optimization strategies for developing an ideal collagen biomatrix and its interactions with CECs and LESCs. Using PRISMA guidelines, articles published from June 2012 to June 2022 were systematically searched using Web of Science (WoS), Scopus, PubMed, Wiley, and EBSCOhost databases. The literature search identified 444 potential relevant published articles, with 29 relevant articles selected based on inclusion and exclusion criteria following screening and appraising processes. Physicochemical and biocompatibility (in vitro and in vivo) characterization methods are highlighted, which are inconsistent throughout various studies. Despite the variability in the methodology approach, it is postulated that the modification of the collagen biomatrix improves its mechanical and biocompatibility properties toward CECs and LESCs. All findings are discussed in this review, which provides a general view of recent trends in this field.
Collapse
|
4
|
ZnO NRs/rGO Photocatalyst in a Polymer-Based Microfluidic Platform. Polymers (Basel) 2023; 15:polym15071749. [PMID: 37050362 PMCID: PMC10097181 DOI: 10.3390/polym15071749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 02/21/2023] [Accepted: 02/26/2023] [Indexed: 04/03/2023] Open
Abstract
This paper reports the development of ZnO NRs/rGO-based photocatalysts integrated into a tree-branched polymer-based microfluidic reactor for efficient photodegradation of water contaminants. The reactor system includes a photocatalytic reactor, tree-branched microfluidic channels, and ZnO nanorods (NRs) coated with reduced graphene oxide (rGO) on a glass substrate within an area of 0.6 × 0.6 cm2. The ZnO NRs/rGO acts as a photocatalyst layer grown hydrothermally and then spray-coated with rGO. The microfluidic system is made of PDMS and fabricated using soft lithography (micro molding using SU-8 master mold patterned on a silicon wafer). The device geometry is designed using AutoCAD software and the flow properties of the microfluidics are simulated using COMSOL Multiphysics. The microfluidic platform’s photocatalytic process aims to bring the nanostructured photocatalyst into very close proximity to the water flow channel, reducing the interaction time and providing effective purification performance. Our functionality test showed that a degradation efficiency of 23.12 %, within the effective residence time of less than 3 s was obtained.
Collapse
|
5
|
A correlation of conductivity medium and bioparticle viability on dielectrophoresis-based biomedical applications. Electrophoresis 2023; 44:573-620. [PMID: 36604943 DOI: 10.1002/elps.202200203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 11/28/2022] [Accepted: 12/26/2022] [Indexed: 01/07/2023]
Abstract
Dielectrophoresis (DEP) bioparticle research has progressed from micro to nano levels. It has proven to be a promising and powerful cell manipulation method with an accurate, quick, inexpensive, and label-free technique for therapeutic purposes. DEP, an electrokinetic phenomenon, induces particle movement as a result of polarization effects in a nonuniform electrical field. This review focuses on current research in the biomedical field that demonstrates a practical approach to DEP in terms of cell separation, trapping, discrimination, and enrichment under the influence of the conductive medium in correlation with bioparticle viability. The current review aims to provide readers with an in-depth knowledge of the fundamental theory and principles of the DEP technique, which is influenced by conductive medium and to identify and demonstrate the biomedical application areas. The high conductivity of physiological fluids presents obstacles and opportunities, followed by bioparticle viability in an electric field elaborated in detail. Finally, the drawbacks of DEP-based systems and the outlook for the future are addressed. This article will aid in advancing technology by bridging the gap between bioscience and engineering. We hope the insights presented in this review will improve cell suspension medium and promote DEP-viable bioparticle manipulation for health-care diagnostics and therapeutics.
Collapse
|
6
|
A dielectrophoresis proof of concept of polystyrene particles and
in‐vitro
human epidermal keratinocytes migration for wound rejuvenation. J Appl Polym Sci 2022. [DOI: 10.1002/app.53096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
7
|
Protein Albumin Manipulation and Electrical Quantification of Molecular Dielectrophoresis Responses for Biomedical Applications. MICROMACHINES 2022; 13:mi13081308. [PMID: 36014230 PMCID: PMC9415755 DOI: 10.3390/mi13081308] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/06/2022] [Accepted: 08/07/2022] [Indexed: 05/17/2023]
Abstract
Research relating to dielectrophoresis (DEP) has been progressing rapidly through time as it is a strong and controllable technique for manipulation, separation, preconcentration, and partitioning of protein. Extensive studies have been carried out on protein DEP, especially on Bovine Serum Albumin (BSA). However, these studies involve the usage of dye and fluorescent probes to observe DEP responses as the physical properties of protein albumin molecular structure are translucent. The use of dye and the fluorescent probe could later affect the protein's physiology. In this article, we review three methods of electrical quantification of DEP responses: electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and capacitance measurement for protein BSA DEP manipulation. The correlation of these methods with DEP responses is further discussed. Based on the observations on capacitance measurement, it can be deduced that the electrical quantifying method is reliable for identifying DEP responses. Further, the possibility of manipulating the protein and electrically quantifying DEP responses while retaining the original physiology of the protein and without the usage of dye or fluorescent probe is discussed.
Collapse
|
8
|
In vitro dielectrophoresis of HEK cell migration for stimulating chronic wound epithelialization. Electrophoresis 2021; 43:609-620. [PMID: 34859896 DOI: 10.1002/elps.202100207] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 11/21/2021] [Accepted: 11/29/2021] [Indexed: 11/10/2022]
Abstract
This article describes a dielectrophoresis (DEP)-based simulation and experimental study of human epidermal keratinocyte (HEK) cells for wounded skin cell migration toward rapid epithelialization. MyDEP is a standalone software designed specifically to study dielectric particles and cell response to an alternating current (AC) electric field. This method demonstrated that negative dielectrophoresis (NDEP ) occurs in HEK cells at a wide frequency range in highly conductive medium. The finite element method was used to characterize particle trajectory based on DEP and drag force. The performance of the system was assessed using HEK cells in a highly conductive EpiLife suspending medium. The DEP experiment was performed by applying sinusoidal wave AC potential at the peak-to-peak voltage of 10 V in a tapered aluminum microelectrode array from 100 kHz to 1 MHz. We experimentally observed the occurrence of NDEP, which attracted HEK cells toward the local electric field minima in the region of interest. The DIPP-MotionV software was used to track cell migration in the prerecorded video via an automatic marker and estimate the average speed and acceleration of the cells. The results showed that HEK cell migration was accomplished approximately at 6.43 μm/s at 100 kHz with 10 V, and FDEP caused the cells to migrate and align at the target position, which resulted in faster wound closures because of the application of an electric field frequency to HEK cells in random locations.
Collapse
|
9
|
Wound Healing with Electrical Stimulation Technologies: A Review. Polymers (Basel) 2021; 13:3790. [PMID: 34771347 PMCID: PMC8588136 DOI: 10.3390/polym13213790] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/16/2021] [Accepted: 10/29/2021] [Indexed: 01/22/2023] Open
Abstract
Electrical stimulation (ES) is an attractive field among clinicians in the topic of wound healing, which is common yet complicated and requires multidisciplinary approaches. The conventional dressing and skin graft showed no promise on complete wound closure. These urge the need for the exploration of electrical stimulation to supplement current wound care management. This review aims to provide an overview of electrical stimulation in wound healing. The mechanism of galvanotaxis related to wound repair will be reviewed at the cellular and molecular levels. Meanwhile, different modalities of externally applied electricity mimicking a physiologic electric field will be discussed and compared in vitro, in vivo, and clinically. With the emerging of tissue engineering and regenerative medicine, the integration of electroconductive biomaterials into modern miniaturised dressing is of interest and has become possible with the advancing understanding of smart biomaterials.
Collapse
|
10
|
Dielectrophoresis applications in biomedical field and future perspectives in biomedical technology. Electrophoresis 2021; 42:2033-2059. [PMID: 34346062 DOI: 10.1002/elps.202100043] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 07/25/2021] [Accepted: 07/27/2021] [Indexed: 11/09/2022]
Abstract
Dielectrophoresis (DEP) is a technique to manipulate trajectories of polarisable particles in non-uniform electric fields by utilising unique dielectric properties. The manipulation of a cell using DEP has been demonstrated in various modes, thereby indicating potential applications in the biomedical field. In this review, recent DEP applications in the biomedical field are discussed. This review is intended to highlight research work that shows significant approach related to dielectrophoresis application in biomedical field reported between 2016 and 2020. Firstly, single-shell model and multiple-shell model of cells are introduced. Current device structures and recently introduced electrode patterns for DEP applications are discussed. Secondly, the biomedical uses of DEP in liquid biopsies, stem cell therapies, and diagnosis of infectious diseases due to bacteria and viruses are presented. Finally, the challenges in DEP research are discussed, and the reported solutions are explained. DEP's potential research directions are mentioned. This article is protected by copyright. All rights reserved.
Collapse
|
11
|
Integration of a Dielectrophoretic Tapered Aluminum Microelectrode Array with a Flow Focusing Technique. SENSORS 2021; 21:s21154957. [PMID: 34372193 PMCID: PMC8347692 DOI: 10.3390/s21154957] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 06/24/2021] [Accepted: 07/07/2021] [Indexed: 12/12/2022]
Abstract
We present the integration of a flow focusing microfluidic device in a dielectrophoretic application that based on a tapered aluminum microelectrode array (TAMA). The characterization and optimization method of microfluidic geometry performs the hydrodynamic flow focusing on the channel. The sample fluids are hydrodynamically focused into the region of interest (ROI) where the dielectrophoresis force (FDEP) is dominant. The device geometry is designed using 3D CAD software and fabricated using the micro-milling process combined with soft lithography using PDMS. The flow simulation is achieved using COMSOL Multiphysics 5.5 to study the effect of the flow rate ratio between the sample fluids (Q1) and the sheath fluids (Q2) toward the width of flow focusing. Five different flow rate ratios (Q1/Q2) are recorded in this experiment, which are 0.2, 0.4, 0.6, 0.8 and 1.0. The width of flow focusing is increased linearly with the flow rate ratio (Q1/Q2) for both the simulation and the experiment. At the highest flow rate ratio (Q1/Q2 = 1), the width of flow focusing is obtained at 638.66 µm and at the lowest flow rate ratio (Q1/Q2 = 0.2), the width of flow focusing is obtained at 226.03 µm. As a result, the flow focusing effect is able to reduce the dispersion of the particles in the microelectrode from 2000 µm to 226.03 µm toward the ROI. The significance of flow focusing on the separation of particles is studied using 10 and 1 µm polystyrene beads by applying a non-uniform electrical field to the TAMA at 10 VPP, 150 kHz. Ultimately, we are able to manipulate the trajectories of two different types of particles in the channel. For further validation, the focusing of 3.2 µm polystyrene beads within the dominant FDEP results in an enhanced manipulation efficiency from 20% to 80% in the ROI.
Collapse
|
12
|
Dielectrophoresis Prototypic Polystyrene Particle Synchronization toward Alive Keratinocyte Cells for Rapid Chronic Wound Healing. SENSORS (BASEL, SWITZERLAND) 2021; 21:3007. [PMID: 33922993 PMCID: PMC8123363 DOI: 10.3390/s21093007] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/25/2021] [Accepted: 04/09/2021] [Indexed: 12/12/2022]
Abstract
Diabetes patients are at risk of having chronic wounds, which would take months to years to resolve naturally. Chronic wounds can be countered using the electrical stimulation technique (EST) by dielectrophoresis (DEP), which is label-free, highly sensitive, and selective for particle trajectory. In this study, we focus on the validation of polystyrene particles of 3.2 and 4.8 μm to predict the behavior of keratinocytes to estimate their crossover frequency (fXO) using the DEP force (FDEP) for particle manipulation. MyDEP is a piece of java-based stand-alone software used to consider the dielectric particle response to AC electric fields and analyzes the electrical properties of biological cells. The prototypic 3.2 and 4.8 μm polystyrene particles have fXO values from MyDEP of 425.02 and 275.37 kHz, respectively. Fibroblast cells were also subjected to numerical analysis because the interaction of keratinocytes and fibroblast cells is essential for wound healing. Consequently, the predicted fXO from the MyDEP plot for keratinocyte and fibroblast cells are 510.53 and 28.10 MHz, respectively. The finite element method (FEM) is utilized to compute the electric field intensity and particle trajectory based on DEP and drag forces. Moreover, the particle trajectories are quantified in a high and low conductive medium. To justify the simulation, further DEP experiments are carried out by applying a non-uniform electric field to a mixture of different sizes of polystyrene particles and keratinocyte cells, and these results are well agreed. The alive keratinocyte cells exhibit NDEP force in a highly conductive medium from 100 kHz to 25 MHz. 2D/3D motion analysis software (DIPP-MotionV) can also perform image analysis of keratinocyte cells and evaluate the average speed, acceleration, and trajectory position. The resultant NDEP force can align the keratinocyte cells in the wound site upon suitable applied frequency. Thus, MyDEP estimates the Clausius-Mossotti factors (CMF), FEM computes the cell trajectory, and the experimental results of prototypic polystyrene particles are well correlated and provide an optimistic response towards keratinocyte cells for rapid wound healing applications.
Collapse
|
13
|
Rapid Manipulation of Extracellular Vesicles using Dielectrophoretic Mechanism. SAINS MALAYS 2020. [DOI: 10.17576/jsm-2020-4912-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Extracellular vesicles (EVs) are small entities that are released by most cell types. EVs are important form of intercellular communication and a rich source of biomarkers for a wide variety of diseases. Many methods for EVs isolation have been utilized, however, most of them have significant drawbacks including lengthy processing time, high cost, shortfalls in selectivity and surface marker dependency. In consideration of these issues, this paper discussed on the dielectrophoresis (DEP) microelectrode method designed to rapidly isolate EVs from its medium. The advantage of this DEP microelectrode is the capability of isolating EVs using a droplet of 1 μL placed onto the microelectrode within 30 s and 20 V peak-to-peak (Vp-p) of alternating current (AC). The method used in the characterization of sample are dynamic light scattering (DLS) and transmission electron microscopy (TEM); both prove the heterogeneity of EVs’ population and the EVs appear to be spherical with size ranging from 40 to 200 nm. The experimental results from this preliminary experiment show that the DEP microelectrode was able to manipulate EVs as evidenced by the negative dielectrophoresis (NDEP) fluorescent images. Further investigation of grid analysis conducted shows the consistency of the theory and the results presented. Corrected Total Cell Fluorescence (CTCF) values from the grid analysis concluded that the EVs were manipulated to the center of region of interest, (ROI). Therefore, this DEP technique suggests a rapid strategy for EVs isolation from its medium in small quantity while maintaining accuracy and cost-effectivity.
Collapse
|
14
|
Rapid ESKAPE Pathogens Detection Method using Tapered Dielectrophoresis Electrodes via Crossover Frequency Analysis. SAINS MALAYS 2020. [DOI: 10.17576/jsm-2020-4912-04] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This paper introduces the versatile of an electrokinetic technique by using the non-uniform electric field for dielectrophoresis (DEP) application. This technique is defined as electromicrofluidics. The potential application for portable and real time detection method of Enterococcus faecium (EF), Staphylococcus aureus (SA), Klebsiella pneumoniae (KP), Acinetobacter baumannii (AB), Pseudomonas aeruginosa (PA) and Enterobacter aerogenes (EA), which are the (ESKAPE) bacteria. The MATLAB analytical modelling was used in simulating the polarisation factor and velocities of bacteria based on Clausius-Mossotti factor (CMF). The validation of CMF simulation through the DEP experimental can be quantified based on the response of alternating current (AC) voltage applied using 6 voltage peak to peak (Vp-p) to their input frequencies from 100 to 15000 kHz. The droplet method was deployed to place properly 0.2 μL of sample onto DEP microelectrode. The velocities and crossover frequency (fxo) ranges of bacteria were determined through bacteria trajectory in specific time interval monitored by microscope attached with eyepiece camera. The applied range of input frequencies from 100 to 15000 kHz at 6 Vp-p for each bacteria were successfully identified the unique ranges of frequencies response for detection application. The advantages of this works are selective with rapid capability for multidrug resistant (MDR) bacteria detection application.
Collapse
|
15
|
Rapid Prototyping of Micropillars using Digital Light Process 3D Printing Technique. SAINS MALAYS 2020. [DOI: 10.17576/jsm-2020-4912-18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this paper, we discuss a technique to fabricate a three-dimensional (3D) printed micropillars structure of microfluidic system. The developed system consists of microchannels, chambers, and micropillars. The creation of arrays of pillars were the focus of the study. The structure is fabricated using a 3D printing technique called Digital Light Process (DLP). In this paper, we examine the potential use of the 3D printing approaches for the fabrication of microfilter and micromixer devices integrated with microfluidic channels. Our 3D printing process shows that micropillars with diameters between 200 and 400 μm can be fabricated using a DLP 3D printer machine by optimizing the preparation process and post processing parameters. Later, SEM analysis shows that micropillars with high aspect ratio and straight side wall were achieved. The DLP 3D printer is the most suitable and reliable technique that can produce the smallest dimension compared to other types of 3D printer that shows a promising method for the rapid prototyping of microfluidic devices for biomedical application.
Collapse
|
16
|
Chaotic Mixing of Microdroplets Using Surface Acoustic Waves Device. JOURNAL OF ADVANCED RESEARCH IN FLUID MECHANICS AND THERMAL SCIENCES 2020; 73:13-24. [DOI: 10.37934/arfmts.73.1.1324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
17
|
Tapered Dielectrophoresis Microelectrodes: Device, Operation, and Application. 2019 IEEE REGIONAL SYMPOSIUM ON MICRO AND NANOELECTRONICS (RSM) 2019. [DOI: 10.1109/rsm46715.2019.8943575] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
18
|
Dielectrophoresis of Amyloid-Beta Proteins as a Microfluidic Template for Alzheimer's Research. Int J Mol Sci 2019; 20:ijms20143595. [PMID: 31340481 PMCID: PMC6678832 DOI: 10.3390/ijms20143595] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 04/25/2019] [Accepted: 04/26/2019] [Indexed: 01/13/2023] Open
Abstract
We employed dielectrophoresis to a yeast cell suspension containing amyloid-beta proteins (Aβ) in a microfluidic environment. The Aβ was separated from the cells and characterized using the gradual dissolution of Aβ as a function of the applied dielectrophoretic parameters. We established the gradual dissolution of Aβ under specific dielectrophoretic parameters. Further, Aβ in the fibril form at the tip of the electrode dissolved at high frequency. This was perhaps due to the conductivity of the suspending medium changing according to the frequency, which resulted in a higher temperature at the tips of the electrodes, and consequently in the breakdown of the hydrogen bonds. However, those shaped as spheroidal monomers experienced a delay in the Aβ fibril transformation process. Yeast cells exposed to relatively low temperatures at the base of the electrode did not experience a positive or negative change in viability. The DEP microfluidic platform incorporating the integrated microtip electrode array was able to selectively manipulate the yeast cells and dissolve the Aβ to a controlled extent. We demonstrate suitable dielectrophoretic parameters to induce such manipulation, which is highly relevant for Aβ-related colloidal microfluidic research and could be applied to Alzheimer’s research in the future.
Collapse
|
19
|
Kesan Sistematik Modifikasi Dielektrik dengan Asid Fosfonik Alkil Ekalapisan terhadap Prestasi Transistor Filem Nipis Organik Saluran-N. SAINS MALAYS 2019. [DOI: 10.17576/jsm-2019-4806-18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
20
|
Dielectrophoretic deformation of breast cancer cells for lab on a chip applications. Electrophoresis 2019; 40:2728-2735. [PMID: 31219180 DOI: 10.1002/elps.201800442] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 04/19/2019] [Accepted: 05/28/2019] [Indexed: 11/08/2022]
Abstract
This paper presents the development and experimental analysis of a curved microelectrode platform for the DEP deformation of breast cancer cells (MDA-MB-231). The platform is composed of arrays of curved DEP microelectrodes which are patterned onto a glass slide and samples containing MDA-MB-231 cells are pipetted onto the platform's surface. Finite element method is utilised to characterise the electric field gradient and DEP field. The performance of the system is assessed with MDA-MB-231 cells in a low conductivity 1% DMEM suspending medium. We applied sinusoidal wave AC potential at peak to peak voltages of 2, 5, and 10 Vpp at both 10 kHz and 50 MHz. We observed cell blebbing and cell shrinkage and analyzed the percentage of shrinkage of the cells. The experiments demonstrated higher percentage of cell shrinkage when cells are exposed to higher frequency and peak to peak voltage electric field.
Collapse
|
21
|
Lab-on-a-chip Dielectrophoretic Manipulation of Beta-2 Microglobulin for Toxin Removal in An Artificial Kidney. MICRO AND NANOSYSTEMS 2019; 11:40-46. [DOI: 10.2174/1876402911666181218145459] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 12/06/2018] [Accepted: 12/12/2018] [Indexed: 09/02/2023]
Abstract
Background:
This paper presents a fundamental study of protein manipulation under the
influence of dielectrophoretic (DEP) force for a lab-on-a-chip platform.
Objective:
Protein manipulation is dependent on the polarisation factor of protein when exposed to an
electric field. Therefore the objective of this work is a microfluidic device and measurement system
are used to characterise the human beta-2 microglobulin (β2M) protein via lateral attractive forces and
vertical repulsive forces by means of DEP responses.
Method:
The manipulation of the β2M protein was conducted using a microfluidic platform with a tapered
DEP microelectrode and the protein concentration was quantified based on a biochemical interaction
using an Enzyme-Linked Immunosolvent Assay (ELISA). The protein distribution has been analysed
based on the β2M concentration for each microfluidic outlet.
Results:
At 300 kHz, the protein experienced a negative DEP (nDEP) with of 83.3% protein distribution
on the middle microchannel. In contrast, the protein experienced a positive DEP (pDEP) at 1.2
MHz with of 78.7% of protein on the left and right sides of the microchannel.
Conclusion:
This is concept proved that the tapered DEP microelectrode is capable of manipulating
a β2M via particle polarisation, hence making it suitable to be utilised for purifying proteins in biomedical
application.
Collapse
|
22
|
Dielectrophoresis velocities response on tapered electrode profile: simulation and experimental. MICROELECTRONICS INTERNATIONAL 2019; 36:45-53. [DOI: 10.1108/mi-06-2018-0037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Purpose
The purpose of this paper is to use a particle velocity measurement technique on a tapered microelectrode device via changes of an applied voltage, which is an enhancement of the electric field density in influencing the dipole moment particles. Polystyrene microbeads (PM) have used to determine the responses of the dielectrophoresis (DEP) voltage based on the particle velocity technique.
Design/methodology/approach
Analytical modelling was used to simulate the particles’ polarization and their velocity based on the Clausius–Mossotti Factor (CMF) equation. The electric field intensity and DEP forces were simulated through the COMSOL numerical study of the variation of applied voltages such as 5 V p-p, 7 V p-p and 10 V p-p. Experimentally, the particle velocity on a tapered DEP response was quantified via the particle travelling distance over a time interval through a high-speed camera adapted to a high-precision non-contact depth measuring microscope.
Findings
The result of the particle velocity was found to increase, and the applied voltage has enhanced the particle trajectory on the tapered microelectrode, which confirmed its dependency on the electric field intensity at the top and bottom edges of the electrode. A higher magnitude of particle levitation was recorded with the highest particle velocity of 11.19 ± 4.43 µm/s at 1 MHz on 10 V p-p, compared to the lowest particle velocity with 0.62 ± 0.11 µm/s at 10 kHz on 7 V p-p.
Practical implications
This research can be applied for high throughout sensitivity and selectivity of particle manipulation in isolating and concentrating biological fluid for biomedical implications.
Originality/value
The comprehensive manipulation method based on the changes of the electrical potential of the tapered electrode was able to quantify the magnitude of the particle trajectory in accordance with the strong electric field density.
Collapse
|
23
|
Separation of Micro Engineered Particle Using Dielectrophoresis Technique. 2018 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) 2018. [DOI: 10.1109/smelec.2018.8481241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
24
|
Voltage Characterization on Dielectrophoretic Force Response to Hematologic Cell Manipulation. 2018 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) 2018. [DOI: 10.1109/smelec.2018.8481286] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
25
|
Size-based particles separation utilizing dielectrophoresis technique. 2017 IEEE REGIONAL SYMPOSIUM ON MICRO AND NANOELECTRONICS (RSM) 2017. [DOI: 10.1109/rsm.2017.8069123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
26
|
Dielectrophoretic force response for Lactobacillus Casei. 2016 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) 2016. [DOI: 10.1109/smelec.2016.7573585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
27
|
Implementing the concept of dielectrophoresis in glomerular filtration of human kidneys. 2016 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) 2016. [DOI: 10.1109/smelec.2016.7573584] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
28
|
A tapered aluminium microelectrode array for improvement of dielectrophoresis-based particle manipulation. SENSORS 2015; 15:10973-90. [PMID: 25970255 PMCID: PMC4481918 DOI: 10.3390/s150510973] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 03/18/2015] [Accepted: 03/20/2015] [Indexed: 12/15/2022]
Abstract
In this work, the dielectrophoretic force (FDEP) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The FDEP is investigated through analysis of the Clausius-Mossotti factor (CMF) and cross-over frequency (fxo). The performance of TAMA with various side wall angles is compared to that of microelectrodes with a straight cut sidewall profile over a wide range of frequencies through FEM numerical simulations. Additionally, electric field measurement (EFM) is performed through scanning probe microscopy (SPM) in order to obtain the region of force focus in both platforms. Results showed that the tapered profile microelectrodes with angles between 60° and 70° produce the highest electric field gradient on the particles. Also, the region of the strongest electric field in TAMA is located at the bottom and top edge of microelectrode while the strongest electric field in microelectrodes with straight cut profile is found at the top corner of the microelectrode. The latter property of microelectrodes improves the probability of capturing/repelling the particles at the microelectrode’s side wall.
Collapse
|
29
|
Optimization of focusing SAW propagation in piezoelectric medium for microfluidic applications. 2015 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP) 2015. [DOI: 10.1109/dtip.2015.7161011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
30
|
FEM analysis of wavelength effects in piezoelectric substrate. 2014 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE2014) 2014. [DOI: 10.1109/smelec.2014.6920846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
31
|
Dielectrophoretic characterization of array type microelectrodes. 2014 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE2014) 2014. [DOI: 10.1109/smelec.2014.6920841] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
32
|
Finite element modeling of dielectrophoretic microelectrodes based on a array and ratchet type. 2014 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE2014) 2014. [DOI: 10.1109/smelec.2014.6920840] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
33
|
Characterization and Optimization of Seals-Off for Very Low Pressure Sensors (VLPS) Fabricated by CMOS MEMS Process. ADVANCED MATERIALS RESEARCH 2009; 74:231-234. [DOI: 10.4028/www.scientific.net/amr.74.231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
In the world of MEMS processing today, fabrications of membrane are performed using bulk micromachining (BMM). However these techniques not easiest to integrate with CMOS standard process due to not compatible of the processing flow. An attractive alternative deployment of surface micromachining (SMM). There is a trend to use surface micromachining to their advantage of simplicity in design and fabrication process compatibility. This paper presents process development of thin layer membrane for very low capacitive pressure sensor application. The structure of the membrane consists of parallel plate which both top and bottom electrodes were fixed at both sides. Utilizing CMOS MEMS process compatible fabrication of the thin layer membrane involved in three stages; i) hole opening etch, ii) sacrificial intermediate oxide release etch and iii) closing of etch holes. Therefore seals-off process characterization and optimization experiment are presented in this paper, will spur advancement in the development of a CMOS MEMS product for very low capacitive pressure sensor.
Collapse
|
34
|
A novel CMOS-compatible fabrication method for development of an electrostatically actuated micropump. 2008 33RD IEEE/CPMT INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY CONFERENCE (IEMT) 2008. [DOI: 10.1109/iemt.2008.5507836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
35
|
Fabrication of thin layer membrane using CMOS process for very low pressure sensor applications. 2008 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS 2008. [DOI: 10.1109/smelec.2008.4770342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
36
|
Development of a CMOS-compatible electrostatically actuated diaphragm chamber for micropump application. 2008 9TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED-CIRCUIT TECHNOLOGY 2008. [DOI: 10.1109/icsict.2008.4735079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|