1
|
LC-MS/MS analysis of components in smoke from e-cigarettes that use guarana extract as the caffeine source. ANAL SCI 2024; 40:959-963. [PMID: 38507147 DOI: 10.1007/s44211-024-00535-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 02/15/2024] [Indexed: 03/22/2024]
Abstract
Currently, e-cigarette products to inhale caffeine (Caf) are commercially available and widely used. Guarana extract (GE) is used as the caffeine source in some e-cigarette products. In this study, an LC-MS/MS analysis of components in the smoke from e-cigarettes with GE was performed. The concentration ranges of Caf and the minor components theophylline (TP), theobromine (TB), and paraxanthine (PX) in e-liquid and cigarette smoke extract (CSE) of five e-cigarette products were determined. The concentration ranges of e-liquid and CSE were 2.17-8.62 mg/mL and 0.17-1.17 µg/puff for Caf, 0.09-37.58 µg/mL and 0.03-11.88 ng/puff for TB, 50.28-185.26 ng/mL and 0.00-0.05 ng/puff for TP, and 0.44-4.09 µg/mL and 0.03-0.20 ng/puff for PX, respectively. By comparing the peak area ratios of e-liquid and CSE, we clarified that the heat degradation of Caf to its related components in GE products was accelerated. Epicatechin, which is another typical component in GE, was determined for CSE, but not for e-liquid.
Collapse
|
2
|
Unique biomedical application of fluorescence derivatization based on palladium-catalyzed coupling reactions for HPLC analysis of pharmaceuticals and biomolecules. Biomed Chromatogr 2024:e5857. [PMID: 38509750 DOI: 10.1002/bmc.5857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/31/2024] [Accepted: 02/13/2024] [Indexed: 03/22/2024]
Abstract
Palladium-catalyzed coupling reactions are versatile and powerful tools for the construction of carbon-carbon bonds in organic synthesis. Although these reactions have favorable features that proceed selectively in mild reaction conditions using aqueous organic solvents, no attention has been given to their application in the field of biomedical analysis. Therefore, we focused on these reactions and evaluated the scope and limitations of their analytical performance. In this review, we describe the pros and cons and future trends of fluorescence derivatization of pharmaceuticals and biomolecules based on palladium-catalyzed coupling reactions such as Suzuki-Miyaura coupling, Mizoroki-Heck coupling, and Sonogashira coupling reactions for HPLC analysis.
Collapse
|
3
|
Biotinylated Quinone as a Chemiluminescence Sensor for Biotin-Avidin Interaction and Biotin Detection Application. SENSORS (BASEL, SWITZERLAND) 2023; 23:9611. [PMID: 38067985 PMCID: PMC10708767 DOI: 10.3390/s23239611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 11/30/2023] [Accepted: 12/02/2023] [Indexed: 12/18/2023]
Abstract
Biotin, or vitamin B7, is essential for metabolic reactions. It must be obtained from external sources such as food and biotin/vitamin supplements because it is not biosynthesized by mammals. Therefore, there is a need to monitor its levels in supplements. However, biotin detection methods, which include chromatographic, immune, enzymatic, and microbial assays, are tedious, time-consuming, and expensive. Thus, we synthesized a product called biotin-naphthoquinone, which produces chemiluminescence upon its redox cycle reaction with dithiothreitol and luminol; then it was used as a chemiluminescence sensor for biotin-avidin interaction. When a quinone biotinylated compound binds avidin, the chemiluminescence decreases noticeably due to the proximity between quinone and avidin, and when free biotin is added in a competitive assay, the chemiluminescence returns. The chemiluminescence is regained as the free biotin displaces biotinylated quinone in its complex with avidin, freeing biotin-naphthoquinone. Many experiments, including the use of a biotin-free quinone, proved the competitive nature of the assay. The competitive assay method used in this study was linear in the range of 1.0-100 µM with a detection limit of 0.58 µM. The competitive chemiluminescence assay could detect biotin in vitamin B7 tablets with good recovery of 91.3 to 110% and respectable precision (RSD < 8.7%).
Collapse
|
4
|
A Turn-On Quinazolinone-Based Fluorescence Probe for Selective Detection of Carbon Monoxide. Molecules 2023; 28:molecules28093654. [PMID: 37175064 PMCID: PMC10180483 DOI: 10.3390/molecules28093654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/16/2023] [Accepted: 04/19/2023] [Indexed: 05/15/2023] Open
Abstract
Carbon monoxide (CO) is a toxic, hazardous gas that has a colorless and odorless nature. On the other hand, CO possesses some physiological roles as a signaling molecule that regulates neurotransmitters in addition to its hazardous effects. Because of the dual nature of CO, there is a need to develop a sensitive, selective, and rapid method for its detection. Herein, we designed and synthesized a turn-on fluorescence probe, 2-(2'-nitrophenyl)-4(3H)-quinazolinone (NPQ), for the detection of CO. NPQ provided a turn-on fluorescence response to CO and the fluorescence intensity at 500 nm was increased with increasing the concentration of CO. This fluorescence enhancement could be attributed to the conversion of the nitro group of NPQ to an amino group by the reducing ability of CO. The fluorescence assay for CO using NPQ as a reagent was confirmed to have a good linear relationship in the range of 1.0 to 50 µM with an excellent correlation coefficient (r) of 0.997 and good sensitivity down to a limit of detection at 0.73 µM (20 ppb) defined as mean blank+3SD. Finally, we successfully applied NPQ to the preparation of a test paper that can detect CO generated from charcoal combustion.
Collapse
|
5
|
Anthracycline-Functionalized Dextran as a New Signal Multiplication Tagging Approach for Immunoassay. BIOSENSORS 2023; 13:340. [PMID: 36979552 PMCID: PMC10046591 DOI: 10.3390/bios13030340] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/21/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
The most used kind of immunoassay is enzyme-linked immunosorbent assay (ELISA); however, enzymes suffer from steric effects, low stability, and high cost. Our research group has been developing quinone-linked immunosorbent assay (QuLISA) as a new promising approach for stable and cost-efficient immunoassay. However, the developed QuLISA suffered from low water-solubility of synthesized quinone labels and their moderate sensitivity. Herein, we developed a new approach for signal multiplication of QuLISA utilizing the water-soluble quinone anthracycline, doxorubicin, coupled with dextran for signal multiplication. A new compound, Biotin-DexDox, was prepared in which doxorubicin was assembled on oxidized dextran 40, and then it was biotinylated. The redox-cycle-based chemiluminescence and the colorimetric reaction of Biotin-DexDox were optimized and evaluated, and they showed very good sensitivity down to 0.25 and 0.23 nM, respectively. Then, Biotin-DexDox was employed for the detection of biotinylated antibodies utilizing avidin as a binder and a colorimetric assay of the formed complex through its contained doxorubicin redox reaction with NaBH4 and imidazolium salt yielding strong absorbance at 510 nm. The method could detect the plate-fixed antibody down to 0.55 nM. Hence, the application of Biotin-DexDox in QuLISA was successfully demonstrated and showed a significant improvement in its sensitivity and applicability to aqueous assays.
Collapse
|
6
|
Development of signal multiplication system for quinone linked immunosorbent assay (Multi-QuLISA) by using poly-l-lysine dendrigraft and 1,2-naphthoquinone-4-sulfonate as enzyme-free tag. Talanta 2023; 253:123911. [PMID: 36137493 DOI: 10.1016/j.talanta.2022.123911] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 12/13/2022]
Abstract
A sensitive and stable signal multiplied quinone-linked immunosorbent assay (Multi-QuLISA) was developed. In Multi-QuLISA, an oligomerized quinone linked to biotin, namely biotin-8mer-naphthoquinone (Bio8mer-NQ), is used as a signal-generating label. Bio8mer-NQ is formed from a dendrigraft poly-l-lysine generation 1 (DPLL G1), a controlled branched oligomer composed of eight lysine moieties with nine free amino groups as a backbone. One of the nine amino groups of DPLL G1 is attached to biotin moiety, while the other eight are attached to 1,2-naphthoquinone-4-sulfonate (NQS). Bio8mer-NQ labels a biotinylated detection antibody using avidin as a co-binder. Then, multi-quinones in Bio8mer-NQ undergo a redox cycle with dithiothreitol and luminol, generating strong chemiluminescence. Standard ELISA uses a label enzyme that suffers from vulnerability in different conditions and poor stability. Bio8mer-NQ showed better stability than the enzyme (biotin-HRP) under different drastic pH and temperature conditions, hydrolytic enzymes, etc. Furthermore, Bio8mer-NQ was used as both chemiluminescence and colorimetric label based on the redox cycle of quinone, and it had LODs of 1.5 and 6.5 nM, respectively. The method could detect biotinylated immunocomplex in an in-house designed immunoassay down to 0.2 nM, which is about 25 times more sensitive than biotin HRP. Eventually, Bio8mer-NQ was applied successfully in Multi-QuLISA for detecting β-casein with a sensitivity of 3.2 ng/mL, while the conventional ELISA had an LOD of 35 ng/mL. Overall, Bio8mer-NQ is a stable compound that could be used as an excellent replacement for the enzyme in immunoassay and can be used in both colorimetric and chemiluminescence assays with good sensitivity.
Collapse
|
7
|
Analysis of vaporized caffeine in smoke from e-cigarettes using liquid chromatography-tandem mass spectrometry and clarification of minor components. Forensic Toxicol 2023; 41:135-141. [PMID: 36652060 DOI: 10.1007/s11419-022-00636-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Accepted: 07/26/2022] [Indexed: 01/21/2023]
Abstract
PURPOSE Electronic cigarettes (e-cigarettes) are used widely, and e-cigarettes containing caffeine (Caf) have recently become commercially available. However, no risk evaluation of these Caf-containing products has been performed to date. Such an evaluation requires a sensitive analytical method for quantifying Caf in smoke from e-cigarettes. The aim of this study was to establish a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying vaporized Caf from commercially available e-cigarettes, and to determine minor components related to Caf in cigarette smoke extract (CSE). METHODS A sampling system for Caf using a suction pump was designed and sampling conditions were optimized. RESULTS The optimized LC-MS/MS conditions allowed the sensitive determination of Caf in smoke with a limit of detection of 0.03 ng/mL at a signal-to-noise ratio of 3. The method was applied to CSEs from five e-cigarette products and the concentration of Caf ranged from 0.894 ± 0.090 to 3.32 ± 0.14 μg/mL smoke (n = 3). Additionally, minor components related to Caf, such as theobromine, theophylline, and paraxanthine, were detected in CSE and in e-liquid at very low concentrations, indicating that they were impurities in e-liquid and vaporized along with Caf. CONCLUSION This is the first report to determine the concentration of vaporized Caf using an LC-MS/MS method and to clarify several minor components in smoke from e-cigarettes.
Collapse
|
8
|
Selective fluorescence labeling of myristicin using Mizoroki-Heck coupling reaction. Application to nutmeg powder, oil, and human plasma samples. J Chromatogr A 2022; 1681:463465. [DOI: 10.1016/j.chroma.2022.463465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/29/2022] [Accepted: 08/31/2022] [Indexed: 11/26/2022]
|
9
|
Development of a selective fluorescence derivatization strategy for thyroid hormones based on the Sonogashira coupling reaction. J Chromatogr A 2022; 1677:463275. [PMID: 35863093 DOI: 10.1016/j.chroma.2022.463275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 12/01/2022]
Abstract
A new fluorescence derivatization technique for the determination of the thyroid hormones, 3,3',5-triiodo-L-thyronine (T3, triiodothyronine) and 3,3',5,5'-tetraiodo-L-thyronine (T4, L-thyroxine), in human serum was developed based on the Sonogashira coupling reaction. This derivatization reaction was recently utilized by our research group as a promising solution for the derivatization of ortho-substituted aryl halides that suffer from steric hindrance. T3 and T4 possess amino groups that could be derivatized by many reagents; however, these reagents are not useful in the case of biological analysis as they could non-selectively react with many biogenic amines and amino acids. Thus, herein we aimed at labeling the iodo-phenyl group of T3 and T4 as a selective fluorescence labeling approach suitable for biological analysis. The fluorescent alkyne, 2-(4-ethynylphenyl)-4,5-diphenyl-1H-imidazole (DIB-ET), can label the ortho-substituted aryl halides T3 and T4 in the presence of palladium and copper as catalysts, overcoming the steric hindrance of ortho-substitution. Furthermore, the application of the proposed method for the selective analysis of T3 and T4 in biological samples was successfully performed even in the presence of numerous biological components. The formed fluorescent derivatives produced from the reaction of DIB-ET and T3 and T4 could be determined by an HPLC system with fluorescence detection. The proposed method was successfully applied for the selective and sensitive determination of T3 and T4 in human serum with detection limits (S/N = 3) of 4.0 and 6.1 ng/mL and the recovery rate in the ranges of 84.3-92.1% and 81.3-84.9%, respectively. Therefore, the proposed method could be used as a new simple tool for the simultaneous determination of T3 and T4 in biological samples.
Collapse
|
10
|
Development of a Selective Assay of Tyrosine and Its Producing and Metabolizing Enzymes Utilizing Pulse-UV Irradiation-Induced Chemiluminescence. Anal Chem 2022; 94:11529-11537. [PMID: 35938883 DOI: 10.1021/acs.analchem.2c01593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A new pulse UV irradiation-induced chemiluminescence (CL) determination method was developed for l-tyrosine using the luminol derivative L-012. The proposed method depends on the formation of reactive oxygen species (ROS) upon pulse UV irradiation of l-tyrosine; then, these ROS react with L-012 producing strong CL. The proposed method showed excellent sensitivity and ultraselectivity toward l-tyrosine. The mechanism of the developed CL method was studied using ROS scavengers, HPLC, and mass spectrometry. The method was linear for l-tyrosine in the range of 0.03-50 μM. Minor changes in the l-tyrosine structure, including hydroxylation, dehydroxylation, phosphorylation, or decarboxylation, were found to lead to a strong decrease in CL. Using the excellent selectivity of the proposed method for l-tyrosine, we have developed a CL assay for measuring alkaline phosphatase activity in the range of 0.02-15 U/L with the limit of detection (LOD) of 4 mU/L using the nonchemiluminescent O-phospho-l-tyrosine as a substrate. Furthermore, the CL reaction was applied for tyrosinase activity assay as this enzyme can convert l-tyrosine to the nonchemiluminescent l-dopa. The decrease in CL is correlated with the tyrosinase activity in the range of 0.025-0.75 U/mL with an LOD of 1.5 mU/mL. Moreover, the tyrosinase activity assay was successfully applied for the determination of IC50 of the tyrosinase inhibitors kojic acid and benzoic acid. Therefore, our novel pulse UV irradiation CL method for the determination of l-tyrosine was not only suitable for the determination of this vital amino acid but also extended to the successful determination of its producing and metabolizing enzymes and their inhibitors.
Collapse
|
11
|
A turn-on hydrazide oxidative decomposition-based fluorescence probe for highly selective detection of Cu2+ in tap water as well as cell imaging. Anal Chim Acta 2022; 1217:340024. [DOI: 10.1016/j.aca.2022.340024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/23/2022] [Accepted: 05/28/2022] [Indexed: 01/31/2023]
|
12
|
Foreword. Chem Pharm Bull (Tokyo) 2022; 70:10-11. [PMID: 34980726 DOI: 10.1248/cpb.c22-ctf7001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
13
|
HPLC Fluorescence Method for Eugenols in Basil Products Derivatized with DIBI. Chem Pharm Bull (Tokyo) 2022; 70:37-42. [PMID: 34980731 DOI: 10.1248/cpb.c21-00575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Eugenols (Eugs) such as eugenol (Eug), methyleugenol (MeEug), and linalool (Lin) in basil product are the main bioactive components of basil products and have a terminal double-bond. A sensitive HPLC-fluorescence method for Eugs derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl)iodobenzene (DIBI) was developed. Good separation of DIB-Eugs was achieved within 20 min on an Atlantis T3 column (50 × 2.1 mm i.d., 3 µm) with a mobile phase of methanol-water. The calibration curves obtained with Eug standards showed good linearities in the range of 0.1-50 µM (r ≥ 0.999). The limits of detection at a signal-to-noise ratio (S/N) = 3 for Eug, MeEug, and Lin were 1.0, 6.0, and 4.8 nM, respectively. The limits of quantitation (S/N = 10) of the Eugs were lower than 19.9 nM. The accuracies for the Eugs were within 96.8-104.6%. The intra- and inter-day precisions as relative standard deviations for the Eugs were less than 1.2 and 9.6% (n = 3). The recoveries of Eug, MeEug, and Lin were 99.0 ± 0.1, 98.0 ± 0.2, and 96.0 ± 0.4% (n = 3), respectively. The DIB-Eugs were confirmed to be stable for 2 h (>90%) at room temperature and 24 h (>95%) at 4 °C. These parameters of the proposed method were useful for the simultaneous determination of Eugs in basil products. Therefore, the developed method may be a powerful tool for the quality evaluation of dried commercially available basil products.
Collapse
|
14
|
Determination Method for Pyrroloquinoline Quinone in Food Products by HPLC-UV Detection Using a Redox-Based Colorimetric Reaction. Chem Pharm Bull (Tokyo) 2022; 70:32-36. [PMID: 34980730 DOI: 10.1248/cpb.c21-00638] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We have developed an HPLC-UV method for the determination of pyrroloquinoline quinone (PQQ), which utilizes a redox-based colorimetric reaction. In the proposed colorimetric reaction, the redox reaction between PQQ and dithiothreitol generates superoxide anion radicals that can convert 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl-2H-tetrazolium chloride (INT) to formazan dye. After PQQ separation on an octadecyl silica column, it was mixed online with dithiothreitol and INT, and the formed formazan dye was monitored by absorbance at 490 nm. The detection limit (S/N = 3) of the proposed method was 7.6 nM (152 fmol/injection). The proposed method could selectively detect PQQ in food products without any clean-up procedures.
Collapse
|
15
|
Simple Fluorescence Assay for Triethylamine Based on the Palladium Catalytic Dimerization of Benzofuran-2-boronic Acid. ANAL SCI 2021; 37:1465-1467. [PMID: 33746139 DOI: 10.2116/analsci.21n007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Although benzofuran-2-boronic acid hardly emits fluorescence, it can be rapidly converted to a highly fluorescent benzofuran dimer after mixing with a palladium catalyst and amine. We found that a fluorescence enhancement accompanying dimerization was quantitatively promoted upon increasing the concentration of amine. In the present study, we developed a simple fluorescence assay for amines based on the promotive effect. As the result of a fluorescence measurement of the reaction mixture of 19 kinds of typical amines, it was found that tertiary amines including triethylamine (TEA) provided a significant fluorescence enhancement. Finally, the fluorogenic reaction could be applied to develop a high-throughput fluorescent microplate assay for TEA with the limit of detection (blank + 3SD) of 0.091 μM.
Collapse
|
16
|
Investigation of immune complexes formed by mitochondrial antigens containing a new lipoylated site in sera of primary biliary cholangitis patients. Clin Exp Immunol 2021; 204:335-343. [PMID: 33605437 DOI: 10.1111/cei.13588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/03/2021] [Accepted: 02/12/2021] [Indexed: 11/30/2022] Open
Abstract
Primary biliary cholangitis (PBC) is characterized by the presence of serum anti-mitochondrial autoantibodies (AMAs). To date, four antigens among the 2-oxo-acid dehydrogenase complex family, which commonly have lipoyl domains as an epitope, have been identified as AMA-corresponding antigens (AMA-antigens). It has recently been reported that AMAs react more strongly with certain chemically modified mimics than with the native lipoyl domains in AMA-antigens. Moreover, high concentrations of circulating immune complexes (ICs) in PBC patients have been reported. However, the existence of ICs formed by AMAs and their antigens has not been reported to date. We hypothesized that AMAs and their antigens formed ICs in PBC sera, and analyzed sera of PBC and four autoimmune diseases (Sjögren's syndrome, systemic lupus erythematosus, systemic scleroderma, and rheumatoid arthritis) using immune complexome analysis, in which ICs are separated from serum and are identified by nano-liquid chromatography-tandem mass spectrometry. To correctly assign MS/MS spectra to peptide sequences, we used a protein-search algorithm that including lipoylation and certain xenobiotic modifications. We found three AMA-antigens, the E2 subunit of the pyruvate dehydrogenase complex (PDC-E2), the E2 subunit of the 2-oxo-glutarate dehydrogenase complex (OGDC-E2) and dihydrolipoamide dehydrogenase binding protein (E3BP), by detecting peptides containing lipoylation and xenobiotic modifications from PBC sera. Although the lipoylated sites of these peptides were different from the well-known sites, abnormal lipoylation and xenobiotic modification may lead to production of AMAs and the formation ICs. Further investigation of the lipoylated sites, xenobiotic modifications, and IC formation will lead to deepen our understanding of PBC pathogenesis.
Collapse
|
17
|
Contributors. GREEN SUSTAINABLE PROCESS FOR CHEMICAL AND ENVIRONMENTAL ENGINEERING AND SCIENCE 2021:xi-xiv. [DOI: 10.1016/b978-0-12-821884-6.09992-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
18
|
A selective and highly sensitive high performance liquid chromatography with fluorescence derivatization approach based on Sonogashira coupling reaction for determination of ethinyl estradiol in river water samples. J Chromatogr A 2020; 1628:461440. [PMID: 32822980 DOI: 10.1016/j.chroma.2020.461440] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 07/19/2020] [Accepted: 07/28/2020] [Indexed: 11/16/2022]
Abstract
A selective and highly sensitive high performance liquid chromatography (HPLC) with fluorescence derivatization method was developed for determination of ethinyl estradiol (EE); one of endocrine-disrupting compounds (EDCs). The fluorescence derivatization procedure was based on Sonogashira coupling reaction using 4-(4, 5-diphenyl-1H-imidazole-2-yl) iodobenzene (DIB-I), a fluorescence labeling reagent, to derivatize EE in presence of copper and palladium ions. The formed fluorescent product was separated on Cosmosil 5C18 MS-II by an isocratic elution with a mobile phase composed of acetonitrile: 5.0 mM Tris-HNO3 buffer, pH 7.4 (60:40, v/v %). The detection wavelengths were set at 310 and 400 nm as excitation and emission wavelengths, respectively. Various parameters affecting derivatization reaction were optimized. Further, the proposed method was validated and a good linearity with low detection limit (S/N=3) 7.4 ng L-1 was obtained in water sample after a simple solid-phase disk extraction (C18 SPE disk) method. The proposed method was successfully applied for detection of EE in river water samples in order to monitor EE concentration and to distinguish its effect on the ecosystem and human health.
Collapse
|
19
|
Long-wavelength Fluorogenic Derivatization of Aryl Halides Based on the Formation of Stilbene by Heck Reaction with Vinylbenzenes. ANAL SCI 2020; 36:997-1001. [PMID: 32173676 DOI: 10.2116/analsci.20p031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 03/03/2020] [Indexed: 08/09/2023]
Abstract
The long-wavelength fluorogenic derivatization method for aryl halides was developed based on stilbene formation by the Heck coupling reaction between aryl halides and vinylbenzenes in the presence of palladium(II) acetate as a catalyst. Fluorescent maximum wavelengths of the derivative obtained by the proposed reaction were 365 - 450 nm, which were 50 - 100 nm longer than those of the biphenyl derivatives formed with our previously developed fluorogenic derivatization method. Also, by the investigation using vinylbenzenes containing electron-donating or -withdrawing functional groups, it was found that an internal charge transfer system could contribute to extend the emission wavelength of the derivative. Furthermore, the proposed reaction was applied to develop a pre-column derivatization HPLC with fluorescence detection method for aryl bromides using 4-vinylanisole. p-Substituted aryl bromide derivatives (i.e., p-bromobenzonitrile, p-bromoanisole, bromobenzene, p-bromobenzoic acid ethyl ester, p-bromotoluene) were successfully detected within 40 min with the detection limit of 0.007 - 0.264 μM. Despite the short reaction time of 10 min, the reaction yields for p-bromoanisole and bromobenzene were good at 101 and 87%, respectively.
Collapse
|
20
|
A Smart Advanced Chemiluminescence-Sensing Platform for Determination and Imaging of the Tissue Distribution of Natural Antioxidants. Anal Chem 2020; 92:6984-6992. [PMID: 32316724 DOI: 10.1021/acs.analchem.0c00044] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Antioxidants have gained marked attention owing to their ability to prevent the oxidation of biological components and to protect the body from reactive oxygen species, thereby maintaining human health. Thus, antioxidant-rich dietary supplements and natural foods can be effective against oxidative stress and can even act as chemopreventive agents. Therefore, a simple and rapid assay for evaluation of antioxidant capacity and assessment of their distribution profile in natural sources is vital. Herein, we report a rapid, innovative chemiluminescence (CL) platform for evaluation and visualization of antioxidant capacity. We found that intense and long-lasting CL was formed upon the redox reaction of quinones, e.g., menadione, with antioxidants, e.g., l-ascorbic acid, in the presence of luminol. The produced CL intensities were proportional to the antioxidants' concentrations with a detection limit of 0.18 μM for the model antioxidant, l-ascorbic acid. As the formed CL was long-lasting, it could be easily captured and detected with a charge-coupled device (CCD) camera. To evaluate the quantification ability of the CCD camera, we developed a smart and fast microplate-based assay based on photographing the generated CL with a cooled CCD camera. The photographed CL intensities were linearly proportional with the antioxidant concentrations, and then the method was applied for photographing multiple food sample extracts. Ultimately, we utilized our method for the distribution profiling of antioxidant capacity in food cut sections. Samples were dipped in luminol and then in quinone, followed by CCD camera photography, without the need for any pulverization/extraction procedure, giving precise antioxidant distribution information.
Collapse
|
21
|
|
22
|
Development of ultrafast colorimetric microplate assay method for ubiquinone utilizing the redox cycle of the quinone. Microchem J 2019. [DOI: 10.1016/j.microc.2019.104104] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
23
|
Chromatographic methods and sample pretreatment techniques for aldehydes determination in biological, food, and environmental samples. J Pharm Biomed Anal 2019; 175:112782. [DOI: 10.1016/j.jpba.2019.112782] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 07/18/2019] [Accepted: 07/18/2019] [Indexed: 11/26/2022]
|
24
|
Detection of hydrogen sulfide in water samples with 2-(4-hydroxyphenyl)-4,5-di(2-pyridyl)imidazole-copper(II) complex using environmentally green microplate fluorescence assay method. Anal Chim Acta 2019; 1057:123-131. [PMID: 30832911 DOI: 10.1016/j.aca.2019.01.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 01/09/2019] [Accepted: 01/10/2019] [Indexed: 01/06/2023]
Abstract
Hydrogen sulfide (H2S) is a colorless toxic gas which can be found as HS- in rivers and waste waters especially in the occupational susceptible environment. Herein we synthesized a lophine analogue, 2-(4-hydroxyphenyl)-4,5-di(2-pyridyl)imidazole (HPI), which fluoresces at 410 nm after excitation at 280 nm. HPI has an imidazole ring and a pyridine ring which are capable of forming coordinate bonds with copper (Cu(II)) that cause quenching of HPI fluorescence. We found that HS- can selectively liberate HPI from the complex via formation of CuS, thus, HPI regains its fluorescence properties. Interestingly, the probe was proved to be regenerable. This reaction was used for the development of a fluorescence microplate assay for the determination of HS- in environmental samples. The method was applied to river water samples and was able to detect HS- in concentrations down to 5 ppb with acceptable accuracy (90.3-103.0%) and good precision (%RSD ≤ 4.1). The method showed many advantages over the previously reported ones including instantaneous reaction, simple probe synthesis, high-throughput, high selectivity toward hydrogen sulfide over other ions and sulfur or thiol containing compounds and at last, it complies with the green chemistry rules through using a regenerable probe, aqueous solvents, and miniaturized measurement system.
Collapse
|
25
|
Novel Isotope-Coded Derivatization Method for Aldehydes Using 14N/15N-Ammonium Acetate and 9,10-Phenanthrenequinone. Anal Chem 2018; 90:13867-13875. [DOI: 10.1021/acs.analchem.8b02458] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
26
|
The Utility of Sonogashira Coupling Reaction for the Derivatization of Aryl Halides with Fluorescent Alkyne. ANAL SCI 2018; 34:1183-1188. [PMID: 30305595 DOI: 10.2116/analsci.18p117] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Aryl halides are a very important category of compounds that include many vital drugs and key industrial additives, such as clofibrate and bromobenzene, respectively. Due to their importance, our research group previously developed a novel fluorescence labeling approach for their analysis using a fluorescent aryl boronic acid as a reagent, based on the Suzuki coupling reaction. This coupling reaction was successfully applied for the determination of aryl halides in biological fluids; however, there was a limitation of low reactivity towards ortho-substituted aryl halides. In the present study, a novel fluorescence derivatization approach for aryl halides was developed using, 2-(4-ethynylphenyl)-4,5-diphenyl-1H-imidazole (DIB-ET) as a fluorescent alkyne reagent, based on the Sonogashira coupling reaction. DIB-ET reacted with aryl bromides in the presence of palladium and copper as catalysts, yielding fluorescent derivatives that could be subsequently determined by an HPLC system with fluorescence detection. The detection limits (S/N = 3) for aryl bromides were in the range of 14 - 23 nM, which is 3.5 - 18-times more sensitive than our previously developed approach, Suzuki coupling derivatization. Moreover, in contrast to the previous technique, the reactivity of DIB-ET to ortho-substituted aryl bromides was almost equivalent to that of the para-substituted aryl bromides. Hence, by using this newly developed approach we could label the aryl halides with more sensitivity and reactivity. Finally, the proposed method was successfully applied for the selective determination of aryl bromides in human serum with good recovery (84.6 - 107%), which proves the ability of the developed method to determine occupational exposure to aryl halides.
Collapse
|
27
|
Aromatic aldehydes as selective fluorogenic derivatizing agents for α‐dicarbonyl compounds. Application to HPLC analysis of some advanced glycation end products and oxidative stress biomarkers in human serum. J Pharm Biomed Anal 2018; 158:38-46. [DOI: 10.1016/j.jpba.2018.05.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 05/09/2018] [Accepted: 05/10/2018] [Indexed: 10/16/2022]
|
28
|
Selective, sensitive and comprehensive detection of immune complex antigens by immune complexome analysis with papain-digestion and elution. J Immunol Methods 2018; 461:85-90. [PMID: 30158077 DOI: 10.1016/j.jim.2018.06.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 06/28/2018] [Accepted: 06/28/2018] [Indexed: 01/06/2023]
Abstract
Comprehensive identification and profiling of antigens in immune complexes (ICs) in biological fluids, such as serum and cerebrospinal fluid, is useful for developing early diagnostic markers and specific treatments for many diseases. We have developed a method, designated "immune complexome analysis", to comprehensively identify the antigens in ICs. In this method, we first purify ICs from biological fluid by using Protein G- or Protein A-coated beads, then these ICs are subjected to tryptic digestion on the beads and subsequent analysis using nano-liquid chromatography-tandem mass spectrometry (nano-LC-MS/MS). We previously used this method to find specific antigens in circulating ICs (CIC-antigens) in serum for autoimmune diseases, infectious disease and cancers. However, this method detects not only CIC-antigens but also antibodies and proteins bound non-specifically to the beads, which restricts the detection of minor peptides released by the digestion of CIC-antigens whose amounts are generally much less than antibodies and the proteins. To selectively detect CIC-antigens with enhanced sensitivity, in this study we compared three methods (Method A, direct tryptic digestion on the beads; Method B, low-pH elution and tryptic digestion; Method C, papain-digestion, elution, and tryptic digestion) and examined which method selectively elutes CIC-antigens from CICs bound to the beads and selectively detects CIC-antigens using nano-LC-MS/MS. We also compared three types of CIC-capturing beads (Protein G-coated magnetic beads, Protein A-coated magnetic beads and Proceptor™-sepharose beads) to examine if parallel use of these beads aids the comprehensive detection of CIC-antigens in immune complexome analysis. Comparison showed that Method C provided the most selective and sensitive detection of CIC-antigens, without interference by antibodies and proteins non-specifically bound to the beads. In addition, using three types of beads allowed the examination of a wide range of CIC-antigens in immune complexome analysis. Therefore, combining Method C with three types of beads should allow the selective and sensitive identification of IC-antigens present in biological fluids from patients with a variety of diseases. The identification of IC-antigens may lead to the development of diagnostic methods and protocols for specific treatments for these diseases.
Collapse
|
29
|
A novel dual labeling approach enables converting fluorescence labeling reagents into fluorogenic ones via introduction of purification tags. Application to determination of glyoxylic acid in serum. Talanta 2018; 180:323-328. [DOI: 10.1016/j.talanta.2017.12.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 12/07/2017] [Accepted: 12/08/2017] [Indexed: 10/18/2022]
|
30
|
Immune complexome analysis of antigens in circulating immune complexes from patients with acute cellular rejection after living donor liver transplantation. Transpl Immunol 2018; 48:60-64. [PMID: 29477751 DOI: 10.1016/j.trim.2018.02.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 02/19/2018] [Accepted: 02/19/2018] [Indexed: 01/10/2023]
Abstract
Liver transplantation is a life-saving procedure for many end-stage liver diseases; however, rejection after transplantation is still occurs in some recipients. The most common form of rejection is T cell-related acute cellular rejection (ACR). To understand the mechanism of rejection, it is necessary to identify immune targets. Since the development of B cell immunity depends upon concordant T cell immunity, we hypothesized that rejection-specific antigens in circulating immune complexes (CICs) may be present in the sera of recipients experiencing rejection, and as such, may be useful as diagnostic biomarkers for ACR. The purpose of this study was to investigate rejection-specific antigens in CICs (CIC-antigens) in serum of ACR patients. We applied immune complexome analysis, in which CICs are separated from whole serum and then subjected to direct tryptic digestion and identification of CIC-antigens by nano-liquid chromatography-tandem mass spectrometry, to sera of 32 living donor liver transplant recipients (10 recipients experienced ACR and the others did not experience). CIC-antigens were compared between rejection and non-rejection groups to elucidate those that were only detected in the rejection group. We identified 11 CIC-antigens that were only detected in patients who experienced rejection, 4 of which (thrombospondin-1, apolipoprotein E, apolipoprotein C-III, and complement factor H) were only detected during ACR.
Collapse
|
31
|
Determination of Tanshinones in Danshen (Salvia miltiorrhiza) by High-Performance Liquid Chromatography with Fluorescence Detection after pre-Column Derivatisation. PHYTOCHEMICAL ANALYSIS : PCA 2018; 29:112-117. [PMID: 28895217 DOI: 10.1002/pca.2719] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 07/22/2017] [Accepted: 07/26/2017] [Indexed: 06/07/2023]
Abstract
INTRODUCTION Tanshinones are a major class of bioactive ingredients in the traditional herbal medicines, Danshen (Salvia miltiorrhiza). A sensitive and reliable determination method for tanshinones is useful to ensure the quality of Danshen. OBJECTIVE To develop a sensitive and selective analytical method for tanshinones by high-performance liquid chromatography (HPLC) with fluorescence detection after pre-column derivatisation. METHODOLOGY The proposed method depends on derivatisation reaction of tanshinones with 4-carbomethoxybenzaldehyde and ammonium acetate forming intensely fluorescent imidazole derivative. RESULTS The proposed method provided excellent sensitivity with the detection limits of 3.3 nM (66 fmol/injection), 3.2 nM (64 fmol/injection) and 2.0 nM (40 fmol/injection) for cryptotanshinone, tanshinone I and tanshinone IIA, respectively, without the necessity of complicated instrumentations. The developed method is successfully applied to quantify the contents of tanshinones in Danshen. CONCLUSION The developed method is the first analytical method for tanshinones by fluorescence detection. Since the derivatisation reaction is selective for the o-quinone structure of tanshinone, the developed method will become a suitable mean for the discovering of tanshinone type diterpenoids from herbal samples. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
|
32
|
Ultrasensitive determination of pyrroloquinoline quinone in human plasma by HPLC with chemiluminescence detection using the redox cycle of quinone. J Pharm Biomed Anal 2017; 145:814-820. [PMID: 28826139 DOI: 10.1016/j.jpba.2017.08.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Revised: 08/03/2017] [Accepted: 08/05/2017] [Indexed: 11/19/2022]
Abstract
A fast, accurate, and ultrasensitive high-performance liquid chromatography method with chemiluminescence detection (HPLC-CL) was optimized and validated for the determination of pyrroloquinoline quinone (PQQ) concentration in human plasma following solid-phase extraction (SPE). This method is based on the redox cycle of the reaction between PQQ and dithiothreitol, which generates reactive oxygen species that can be detected using luminol as a CL probe. The isocratic HPLC system comprised an ODS column and 4.0mM tetra-n-butylammonium bromide in Tris-HNO3 buffer (pH 8.8; 50mM)-acetonitrile (7:3, v/v) as mobile phase. A novel, rapid, and simple SPE method was also developed providing excellent %recovery (≥95.2%) for PQQ from human plasma samples. The proposed method was linear over the range of 4.0-400nmol/L plasma of PQQ with a lower detection limit (S/N=3) of 1.08 nmol/L plasma (0.27nM). The method was successfully implemented to determine PQQ concentration in the plasma of healthy individuals after administration of PQQ supplements.
Collapse
|
33
|
A simple and highly selective fluorescent sensor for palladium based on benzofuran-2-boronic acid. Tetrahedron Lett 2017. [DOI: 10.1016/j.tetlet.2017.06.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
34
|
Development of an Evaluation Method for Hydroxyl Radical Scavenging Activities Using Sequential Injection Analysis with Chemiluminescence Detection. ANAL SCI 2017; 33:697-701. [PMID: 28603188 DOI: 10.2116/analsci.33.697] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A method for evaluating hydroxyl radical (·OH) scavenging activities using sequential injection analysis (SIA) with chemiluminescence (CL) detection was developed. In this system, CL was produced by the reaction of luminol with ·OH generated from the Fenton reaction. The scavenging activity was expressed as a diminution rate of the CL due to the scavenging of ·OH by a sample. The SIA system allows the automation of a series of experimental procedures including Fenton's reaction, scavenging of ·OH, and luminol CL reaction. The evaluation of scavenging activities in one sample (n = 3) was completed within 3.0 min. Relative standard deviations (n = 3) of scavenging activity with 700 μM L-ascorbic acid were 2.6% (intraday) and 3.7% (interday). The SIA-CL system was applied to measure ·OH scavenging activities of several antioxidants and pharmaceuticals.
Collapse
|
35
|
Redox-based chemiluminescence assay of aminothiols in human urine: A fundamental study. Talanta 2017; 164:116-120. [DOI: 10.1016/j.talanta.2016.11.042] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 11/18/2016] [Accepted: 11/19/2016] [Indexed: 01/03/2023]
|
36
|
Immune complexome analysis reveals the specific and frequent presence of immune complex antigens in lung cancer patients: A pilot study. Int J Cancer 2016; 140:370-380. [DOI: 10.1002/ijc.30455] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 09/16/2016] [Indexed: 12/29/2022]
|
37
|
9,10-Phenanthrenequinone as a mass-tagging reagent for ultra-sensitive liquid chromatography–tandem mass spectrometry assay of aliphatic aldehydes in human serum. J Chromatogr A 2016; 1462:80-9. [DOI: 10.1016/j.chroma.2016.07.082] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Revised: 07/20/2016] [Accepted: 07/28/2016] [Indexed: 10/21/2022]
|
38
|
Quinones as novel chemiluminescent probes for the sensitive and selective determination of biothiols in biological fluids. Analyst 2016; 140:8148-56. [PMID: 26535414 DOI: 10.1039/c5an01604e] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Altered plasma aminothiol concentrations are thought to be a valuable risk indicator and are interestingly utilized for routine clinical diagnosis and for the monitoring of various metabolic disorders and human diseases, and accordingly there is a need for an accurate and reliable assay capable of simultaneously determining aminothiols including glutathione (GSH), N-acetylcysteine (NAC), homocysteine (Hcys), and cysteine (Cys) in human plasma. Herein, a highly sensitive, selective, and very fast HPLC-chemiluminescence (HPLC-CL) coupled method is reported, exploiting for the first time the strong nucleophilicity and high reactivity of aminothiols toward quinones for a CL assay. The unique redox-cycling capability of quinone and/or Michael addition adducts, thioether-quinone conjugates, was utilized to establish a novel analytical method based on the reaction of adducts with dithiothreitol (DTT) to liberate reactive oxygen species (ROS), which are detected by using a luminol-CL assay. Specimen preparation involved the derivatization of aminothiols with menadione (MQ) for 5 minutes at room temperature. A unique green chemistry synthesis of thioether-quinones in HEPES buffer (pH 8.5) was introduced by using our reaction methodology without needing any hazardous organic solvent or catalyst. The aminothiol-MQ adducts were separated using solid-phase extraction followed by isocratic elution on an ODS column. Linearity was observed in the range of 2.5-500, 5-500, 10-1500, and 20-2000 nM with detection limits (S/N of 3) of 3.8, 4.2, 8, and 16 (fmol per injection) for GSH, NAC, Hcys, and Cys, respectively. The method was successfully applied for the selective determination of aminothiols in human plasma from healthy people and patients with rheumatic arthritis and diabetes mellitus. The obtained results postulated the usefulness of our method for investigating the relationship between aminothiol metabolism and related human disorders.
Collapse
|
39
|
Proteomic profile of circulating immune complexes in chronic Chagas disease. Parasite Immunol 2016; 38:609-17. [PMID: 27223052 DOI: 10.1111/pim.12341] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 04/22/2016] [Indexed: 12/21/2022]
Abstract
Immune complexes (ICs) are the direct and real-time products of humoral immune responses. The identification of constituent foreign or autoantigens within ICs might bring new insights into the pathology of infectious diseases. We applied immune complexome analysis of plasma to the study of Chagas disease caused by Trypanosoma cruzi. Twenty seropositive plasma samples including cardiac and/or megacolon determinate patients (n = 11) and indeterminate (n = 9) were analysed along with 10 seronegative individuals to characterize the antigens bound to circulating ICs. We identified 39 T. cruzi antigens and 114 human autoantigens specific to patients with Chagas. Among those antigens, two T. cruzi antigens (surface protease GP63, glucose-6-isomerase) and six human autoantigens (CD180 antigen, ceruloplasmin, fibrinogen beta chain, fibrinogen beta chain isoform 2 preprotein, isoform gamma-A of fibrinogen γ-chain, serum paraoxonase) were detected in more than 50% of the patients tested. Human isoform short of complement factor H-related protein 2 and trans-sialidase of T. cruzi were more frequently found in the indeterminate (5/9 for both) compared with in the determinate Chagas (0/11, P = 0·046 for human, 1/11, P = 0·0498 for T. cruzi). The immune complexome could illustrate the difference of immune status between clinical forms of chronic Chagas disease.
Collapse
|
40
|
Spatial correlativity of atmospheric particulate components simultaneously collected in Japan. ENVIRONMENTAL MONITORING AND ASSESSMENT 2016; 188:85. [PMID: 26753629 DOI: 10.1007/s10661-015-5029-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Accepted: 12/02/2015] [Indexed: 06/05/2023]
Abstract
The simultaneous sampling of total suspended particles was performed at 14 sites in Japan during July 2008-June 2009. The spatial correlativity of each particulate composition toward Osaka was obtained for nine selected sites to overview the chemical composition and geographical distribution of particulate components across a wide range of areas nationwide. The spatial correlatives of atmospheric particulate components were extended to an even wider range of areas up to 950 km distance (meso-alpha scale region, >200 km) for a far-reaching distance analysis unique in the literature. Overall, the spatial correlations of ionic species and both organic and elemental carbons were significant, suggesting their shared advections, including their long-range transport from East Asia. Although sulfate ions are widely dispersed across Japan, such is not necessarily correlated with organic and elemental carbon, possibly indicating that the sulfate emission source, including long-range transport, differs from that of carbonaceous particulates. By contrast, the characteristics of spatial correlatives of metallic constituents vary; for example, particulate Pb and Cd show a significantly wide range of spatial correlatives to Osaka, while Mn-though limited to cities neighboring Osaka-shows significant spatial correlations. Other metallic constituents showed no significant spatial correlatives, indicating the effects of local pollutants. Moreover, the extent of the spatial dispersion of the particulate components and the relationships among chemical components were analyzed via factor analysis to highlight the effects of long-range inflow and local original emissions. In this treatment, 13 particulate components among the 19 measured were implicated in long-range transport.
Collapse
|
41
|
Molecular-shape selectivity by naphthalimido-modified silica stationary phases: Insight into the substituents effect of naphthalene on shape recognition and π–π interactions via electrostatic potential. J Chromatogr A 2015; 1425:173-9. [DOI: 10.1016/j.chroma.2015.11.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/02/2015] [Accepted: 11/08/2015] [Indexed: 11/26/2022]
|
42
|
Immune complexome analysis of antigens in circulating immune complexes isolated from patients with IgG4-related dacryoadenitis and/or sialadenitis. Mod Rheumatol 2015; 26:248-50. [DOI: 10.3109/14397595.2015.1072296] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
43
|
[Chemiluminescence assay for the investigation of reactive oxygen species generator]. YAKUGAKU ZASSHI 2015; 135:191-6. [PMID: 25747212 DOI: 10.1248/yakushi.14-00213-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Quinones play critical roles in biological systems, but are also regarded as a class of toxins that can cause oxidative stress in living cells, and the involvement of quinone-based reactive oxygen species in oxidative stress has been reported. In biological systems, quinones are reduced to semiquinone radicals by the enzyme NADPH:quinone reductase. Next, semiquinone radicals react with dissolved oxygen to form superoxide anion, which reacts with biological molecules to cause oxidative stress. On the other hand, chemiluminescence reagents such as luminol can emit chemiluminescence after oxidation by reactive oxygen species. Therefore, chemiluminescence reagents have been used widely to investigate reactive oxygen species. We have developed a sensitive and selective assay for quantifying quinones using luminol chemiluminescence. This chemiluminescence assay is based on the generation of reactive oxygen species through the redox reaction between quinone and dithiothreitol, a reductant, followed by detection of the generated reactive oxygen by luminol. Additionally, this assay can be used to quantify the toxic herbicide, paraquat, which produces reactive oxygen species in the same manner as quinones. This review describes the development of a sensitive and selective chemiluminescence assay for investigating quinones and paraquat by utilizing their ability to generate reactive oxygen species.
Collapse
|
44
|
The Creation of Useful Analytical Tools to Elucidate Biological Phenomena. YAKUGAKU ZASSHI 2015; 135:189-90. [DOI: 10.1248/yakushi.14-00213-f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
45
|
Poly(l-lactic acid)-modified silica stationary phase for reversed-phase and hydrophilic interaction liquid chromatography. J Sep Sci 2015; 38:720-3. [DOI: 10.1002/jssc.201401243] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 12/16/2014] [Accepted: 12/16/2014] [Indexed: 11/07/2022]
|
46
|
Determination of acrolein in serum by high-performance liquid chromatography with fluorescence detection after pre-column fluorogenic derivatization using 1,2-diamino-4,5-dimethoxybenzene. Biomed Chromatogr 2015; 29:1304-8. [PMID: 25620324 DOI: 10.1002/bmc.3422] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 11/19/2014] [Accepted: 11/30/2014] [Indexed: 01/24/2023]
Abstract
Acrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high-performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum. The proposed method involves the pre-column fluorogenic derivatization of acrolein with 1,2-diamino-4,5-dimethoxybenzene (DDB) as a reagent. The fluorescent derivative of acrolein could be detected clearly without any interfering reagent blank peaks because DDB does not have intrinsic fluorescence itself, and the detection limit was 10 nM (signal-to-noise ratio = 3). The proposed method could selectively detect acrolein in human serum with a simple protein precipitation treatment.
Collapse
|
47
|
Molecular modeling and spectroscopic study of quinone–protein adducts: insight into toxicity, selectivity, and reversibility. Toxicol Res (Camb) 2015. [DOI: 10.1039/c5tx00098j] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The toxicity, reversibility and selectivity of quinone–protein adducts were studied using molecular modeling and molecular spectroscopy. Adduction of quinones with proteins could affect their redox potential, bioavailability, and intracellular distribution.
Collapse
|
48
|
Preparation and characterization of surfactin-modified silica stationary phase for reversed-phase and hydrophilic interaction liquid chromatography. J Chromatogr A 2014; 1371:257-60. [PMID: 25456604 DOI: 10.1016/j.chroma.2014.10.073] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 09/20/2014] [Accepted: 10/24/2014] [Indexed: 11/18/2022]
Abstract
Surfactants are good candidates as selectors in mixed-mode reversed-phase liquid chromatography (RPLC)/hydrophilic interaction liquid chromatography (HILIC) because they contain both a hydrophobic and a hydrophilic moiety. Surfactin, a cyclic heptapeptide, is an efficient biosurfactant produced by Bacillus subtilis that comprises seven amino acids and a β-hydroxyl fatty acid. A surfactin-modified silica (SMS) stationary phase was prepared by amide bond formation between amino groups on aminopropyl silica and the carboxylic acid groups of L-Glu and L-Asp residues in surfactin. The resulting SMS stationary phase was characterized in both RPLC and HILIC mode using different mobile phases. The SMS column was found to separate analytes in both modes. The retention of polar solutes exhibited "U-shaped" curves, depending on the acetonitrile content. "U-shaped" curves are an indicator of RPLC/HILIC mixed-mode retention behavior. The presence of hydrophobic and hydrophilic moieties in surfactin provides unique properties that allow the SMS column to be used for both RPLC and HILIC separations, simply by changing the mobile phase composition.
Collapse
|
49
|
Analytical method for lipoperoxidation relevant reactive aldehydes in human sera by high-performance liquid chromatography-fluorescence detection. Anal Biochem 2014; 464:36-42. [PMID: 25017470 DOI: 10.1016/j.ab.2014.07.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Revised: 07/02/2014] [Accepted: 07/03/2014] [Indexed: 10/25/2022]
Abstract
A validated, simple and sensitive HPLC method was developed for the simultaneous determination of lipoperoxidation relevant reactive aldehydes: glyoxal (GO), acrolein (ACR), malondialdehyde (MDA), and 4-hydroxy-2-nonenal (HNE) in human serum. The studied aldehydes were reacted with 2,2'-furil to form fluorescent difurylimidazole derivatives that were separated on a C18 column using gradient elution and fluorescence detection at excitation and emission wavelengths of 250 and 355nm, respectively. The method showed good linearity over the concentration ranges of 0.100-5.00, 0.200-10.0, 0.200-40.0, and 0.400-10.0nmol/mL for GO, ACR, HNE, and MDA, respectively, with detection limits ranging from 0.030 to 0.11nmol/mL. The percentage RSD of intraday and interday precision did not exceed 5.0 and 6.2%, respectively, and the accuracy (%found) ranged from 95.5 to 103%. The proposed method was applied for monitoring the four aldehydes in sera of healthy, diabetic, and rheumatic human subjects with simple pretreatment steps and without interference from endogenous components. By virtue of its high sensitivity and accuracy, our method enabled detection of differences between analytes concentrations in sera of human subjects under different clinical conditions.
Collapse
|
50
|
Determination of 4-hydroxy-2-nonenal in serum by high-performance liquid chromatography with fluorescence detection after pre-column derivatization using 4-(N,N-dimethylaminosulfonyl)-7-hydrazino-2,1,3-benzoxadiazole. Biomed Chromatogr 2014; 28:891-4. [DOI: 10.1002/bmc.3204] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|