1
|
Drabińska N, Młynarz P, de Lacy Costello B, Jones P, Mielko K, Mielnik J, Persad R, Ratcliffe NM. An Optimization of Liquid-Liquid Extraction of Urinary Volatile and Semi-Volatile Compounds and Its Application for Gas Chromatography-Mass Spectrometry and Proton Nuclear Magnetic Resonance Spectroscopy. Molecules 2020; 25:E3651. [PMID: 32796601 PMCID: PMC7463579 DOI: 10.3390/molecules25163651] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 08/06/2020] [Accepted: 08/10/2020] [Indexed: 02/07/2023] Open
Abstract
Urinary volatile compounds (VCs) have been recently assessed for disease diagnoses. They belong to very diverse chemical classes, and they are characterized by different volatilities, polarities and concentrations, complicating their analysis via a single analytical procedure. There remains a need for better, lower-cost methods for VC biomarker discovery. Thus, there is a strong need for alternative methods, enabling the detection of a broader range of VCs. Therefore, the main aim of this study was to optimize a simple and reliable liquid-liquid extraction (LLE) procedure for the analysis of VCs in urine using gas chromatography-mass spectrometry (GC-MS), in order to obtain the maximum number of responses. Extraction parameters such as pH, type of solvent and ionic strength were optimized. Moreover, the same extracts were analyzed using Proton Nuclear Magnetic Resonance Spectroscopy (1H-NMR), to evaluate the applicability of a single urine extraction for multiplatform purposes. After the evaluation of experimental conditions, an LLE protocol using 2 mL of urine in the presence of 2 mL of 1 M sulfuric acid and sodium sulphate extracted with dichloromethane was found to be optimal. The optimized method was validated with the external standards and was found to be precise and linear, and allowed for detection of >400 peaks in a single run present in at least 50% of six samples-considerably more than the number of peaks detected by solid-phase microextracton fiber pre-concentration-GC-MS (328 ± 6 vs. 234 ± 4). 1H-NMR spectroscopy of the polar and non-polar extracts extended the range to >40 more (mainly low volatility compounds) metabolites (non-destructively), the majority of which were different from GC-MS. The more peaks detectable, the greater the opportunity of assessing a fingerprint of several compounds to aid biomarker discovery. In summary, we have successfully demonstrated the potential of LLE as a cheap and simple alternative for the analysis of VCs in urine, and for the first time the applicability of a single urine solvent extraction procedure for detecting a wide range of analytes using both GC-MS and 1H-NMR analysis to enhance putative biomarker detection. The proposed method will simplify the transport between laboratories and storage of samples, as compared to intact urine samples.
Collapse
Affiliation(s)
- Natalia Drabińska
- Institute of Animal Reproduction and Food Research of Polish Academy of Sciences, 10 Tuwima Str., 10-748 Olsztyn, Poland
- Institute of Biosensor Technology, University of the West of England, Coldharbour Lane, Frenchay, Bristol BS16 1QY, UK;
| | - Piotr Młynarz
- Department of Biochemistry, Molecular Biology and Biotechnology, Faculty of Chemistry, Wroclaw University of Science and Technology, 27 Wybrzeże Stanisława Wyspianskiego, 50-370 Wroclaw, Poland; (P.M.); (K.M.); (J.M.)
| | - Ben de Lacy Costello
- Institute of Biosensor Technology, University of the West of England, Coldharbour Lane, Frenchay, Bristol BS16 1QY, UK;
| | | | - Karolina Mielko
- Department of Biochemistry, Molecular Biology and Biotechnology, Faculty of Chemistry, Wroclaw University of Science and Technology, 27 Wybrzeże Stanisława Wyspianskiego, 50-370 Wroclaw, Poland; (P.M.); (K.M.); (J.M.)
| | - Justyna Mielnik
- Department of Biochemistry, Molecular Biology and Biotechnology, Faculty of Chemistry, Wroclaw University of Science and Technology, 27 Wybrzeże Stanisława Wyspianskiego, 50-370 Wroclaw, Poland; (P.M.); (K.M.); (J.M.)
| | - Raj Persad
- Bristol Urological Institute, Southmead Hospital, Bristol BS10 5BN, UK;
| | - Norman Mark Ratcliffe
- Institute of Biosensor Technology, University of the West of England, Coldharbour Lane, Frenchay, Bristol BS16 1QY, UK;
| |
Collapse
|
2
|
Drabińska N, Jarocka-Cyrta E, Ratcliffe NM, Krupa-Kozak U. The Profile of Urinary Headspace Volatile Organic Compounds After 12-Week Intake of Oligofructose-Enriched Inulin by Children and Adolescents with Celiac Disease on a Gluten-Free Diet: Results of a Pilot, Randomized, Placebo-Controlled Clinical Trial. Molecules 2019; 24:E1341. [PMID: 30959740 PMCID: PMC6479364 DOI: 10.3390/molecules24071341] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 04/01/2019] [Accepted: 04/04/2019] [Indexed: 12/26/2022] Open
Abstract
The concentration of volatile organic compounds (VOCs) can inform about the metabolic condition of the body. In the small intestine of untreated persons with celiac disease (CD), chronic inflammation can occur, leading to nutritional deficiencies, and consequently to functional impairments of the whole body. Metabolomic studies showed differences in the profile of VOCs in biological fluids of patients with CD in comparison to healthy persons; however, there is scarce quantitative and nutritional intervention information. The aim of this study was to evaluate the effect of the supplementation of a gluten-free diet (GFD) with prebiotic oligofructose-enriched inulin (Synergy 1) on the concentration of VOCs in the urine of children and adolescents with CD. Twenty-three participants were randomized to the group receiving Synergy 1 (10 g per day) or placebo for 12 weeks. Urinary VOCs were analyzed using solid-phase microextraction and gas chromatography⁻mass spectrometry. Sixteen compounds were identified and quantified in urine samples. The supplementation of GFD with Synergy 1 resulted in an average concentration drop (36%) of benzaldehyde in urine samples. In summary, Synergy 1, applied as a supplement of GFD for 12 weeks had a moderate impact on the VOC concentrations in the urine of children with CD.
Collapse
Affiliation(s)
- Natalia Drabińska
- Department of Chemistry and Biodynamics of Food, Institute of Animal Reproduction and Food Research of Polish Academy of Sciences, Tuwima 10 Str., 10-748 Olsztyn, Poland.
| | - Elżbieta Jarocka-Cyrta
- Department of Pediatrics, Gastroenterology, and Nutrition, Collegium Medicum, University of Warmia & Mazury, Oczapowskiego 2 Str., 10-719 Olsztyn, Poland.
| | - Norman Mark Ratcliffe
- Institute of Biosensor Technology, the University of the West of England, University of the West of England, Coldharbour Lane, Frenchay, Bristol BS16 1QY, UK.
| | - Urszula Krupa-Kozak
- Department of Chemistry and Biodynamics of Food, Institute of Animal Reproduction and Food Research of Polish Academy of Sciences, Tuwima 10 Str., 10-748 Olsztyn, Poland.
| |
Collapse
|
3
|
Aggio RBM, White P, Jayasena H, de Lacy Costello B, Ratcliffe NM, Probert CSJ. Irritable bowel syndrome and active inflammatory bowel disease diagnosed by faecal gas analysis. Aliment Pharmacol Ther 2017; 45:82-90. [PMID: 27862117 DOI: 10.1111/apt.13822] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Revised: 05/16/2016] [Accepted: 09/14/2016] [Indexed: 12/19/2022]
Abstract
BACKGROUND Inflammatory bowel disease and irritable bowel syndrome may present in a similar manner. Measuring faecal calprotectin concentration is often recommended to rule out inflammatory bowel disease, however, there are no tests to positively diagnose irritable bowel syndrome and invasive tests are still used to rule out other pathologies. AIM To investigate a platform technology for diagnosing inflammatory bowel disease and irritable bowel syndrome based on faecal gas. METHODS The platform technology is composed of a gas chromatography column coupled to a metal oxide gas sensor (OdoReader) and a computer algorithm. The OdoReader separates the volatile compounds from faecal gas and the computer algorithm identifies resistance patterns associated with specific medical conditions and builds classification models. This platform was applied to faecal samples from 152 patients: 33 patients with active inflammatory bowel disease; 50 patients with inactive inflammatory bowel disease; 28 patients with irritable bowel syndrome and 41 healthy donors (Control). RESULTS The platform classified samples with accuracies from 75% to 100% using rigorous validation schemes: namely leave-one-out cross-validation, 10-fold cross-validation, double cross-validation and their Monte Carlo variations. The most clinically important findings, after double cross-validation, were the accuracy of active Crohn's disease vs. irritable bowel syndrome (87%; CI 84-89%) and irritable bowel syndrome vs. controls (78%; CI 76-80%). These schemes provide an estimate of out-of-sample predictive accuracy for similar populations. CONCLUSIONS This is the first description of an investigation for the positive diagnosis of irritable bowel syndrome, and for diagnosing inflammatory bowel disease.
Collapse
Affiliation(s)
- R B M Aggio
- Department of Cellular and Molecular Physiology, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - P White
- Department of Engineering, Design and Mathematics, University of the West of England, Bristol, UK
| | - H Jayasena
- Department of Clinical Medicine, Faculty of Medicine, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka
| | - B de Lacy Costello
- Institute of Biosensor Technology, University of the West of England, Bristol, UK
| | - N M Ratcliffe
- Institute of Biosensor Technology, University of the West of England, Bristol, UK
| | - C S J Probert
- Department of Cellular and Molecular Physiology, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| |
Collapse
|
4
|
Shepherd SF, McGuire ND, de Lacy Costello BPJ, Ewen RJ, Jayasena DH, Vaughan K, Ahmed I, Probert CS, Ratcliffe NM. The use of a gas chromatograph coupled to a metal oxide sensor for rapid assessment of stool samples from irritable bowel syndrome and inflammatory bowel disease patients. J Breath Res 2014; 8:026001. [PMID: 24674940 PMCID: PMC4871257 DOI: 10.1088/1752-7155/8/2/026001] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
There is much clinical interest in the development of a low-cost and reliable test for diagnosing inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), two very distinct diseases that can present with similar symptoms. The assessment of stool samples for the diagnosis of gastro-intestinal diseases is in principle an ideal non-invasive testing method. This paper presents an approach to stool analysis using headspace gas chromatography and a single metal oxide sensor coupled to artificial neural network software. Currently, the system is able to distinguish samples from patients with IBS from patients with IBD with a sensitivity and specificity of 76% and 88% respectively, with an overall mean predictive accuracy of 76%.
Collapse
Affiliation(s)
- S F Shepherd
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| | - N D McGuire
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| | - B P J de Lacy Costello
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| | - R J Ewen
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| | - D H Jayasena
- Bristol Royal Infirmary, Upper Maudlin Street, Bristol, BS2 8HW
| | - K Vaughan
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| | - I Ahmed
- Bristol Royal Infirmary, Upper Maudlin Street, Bristol, BS2 8HW
| | - C S Probert
- Institute of Translational Medicine, University of Liverpool, Crown Street, Liverpool L69 3BX
| | - N M Ratcliffe
- Institute of Bio-sensing Technology, University of the West of England, Bristol, BS16 1QY
| |
Collapse
|
5
|
McGuire ND, Ewen RJ, de Lacy Costello B, Garner CE, Probert CSJ, Vaughan K, Ratcliffe NM. Towards point of care testing for C. difficile infection by volatile profiling, using the combination of a short multi-capillary gas chromatography column with metal oxide sensor detection. Meas Sci Technol 2014; 25:065108. [PMID: 27212803 PMCID: PMC4874467 DOI: 10.1088/0957-0233/25/6/065108] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor (MOS) sensor and artificial neural network (ANN) software. For direct analysis of biological samples this prototype offers alternatives to conventional GC detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenised in house 'standard' stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 minutes compared to 30 minutes for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden.
Collapse
Affiliation(s)
- N D McGuire
- Institute of Biosensing Technology, University of the West of England, Bristol, United Kingdom
| | - R J Ewen
- Institute of Biosensing Technology, University of the West of England, Bristol, United Kingdom
| | - B de Lacy Costello
- Institute of Biosensing Technology, University of the West of England, Bristol, United Kingdom
| | - C E Garner
- Institute of Biosensing Technology, University of the West of England, Bristol, United Kingdom
| | - C S J Probert
- Institute of Translational Medicine, University of Liverpool, Liverpool, United Kingdom
| | | | - N M Ratcliffe
- Institute of Biosensing Technology, University of the West of England, Bristol, United Kingdom
| |
Collapse
|
6
|
de Lacy Costello B, Amann A, Al-Kateb H, Flynn C, Filipiak W, Khalid T, Osborne D, Ratcliffe NM. A review of the volatiles from the healthy human body. J Breath Res 2014. [PMID: 24421258 DOI: 10.1088/17527155/8/1/014001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/18/2023]
Abstract
A compendium of all the volatile organic compounds (VOCs) emanating from the human body (the volatolome) is for the first time reported. 1840 VOCs have been assigned from breath (872), saliva (359), blood (154), milk (256), skin secretions (532) urine (279), and faeces (381) in apparently healthy individuals. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been grouped into tables according to their chemical class or functionality to permit easy comparison. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces. Careful use of the database is needed. The numbers may not be a true reflection of the actual VOCs present from each bodily excretion. The lack of a compound could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from blood compared to a large number on VOCs in breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. collecting excretions on glass beads and then heating to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors' intention that this database will not only be a useful database of VOCs listed in the literature, but will stimulate further study of VOCs from healthy individuals. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.
Collapse
Affiliation(s)
- B de Lacy Costello
- Institute of Biosensor Technology, University of the West of England, Bristol BS16 1QY, UK
| | | | | | | | | | | | | | | |
Collapse
|
7
|
de Lacy Costello B, Amann A, Al-Kateb H, Flynn C, Filipiak W, Khalid T, Osborne D, Ratcliffe NM. A review of the volatiles from the healthy human body. J Breath Res 2014; 8:014001. [PMID: 24421258 DOI: 10.1088/1752-7155/8/1/014001] [Citation(s) in RCA: 507] [Impact Index Per Article: 50.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A compendium of all the volatile organic compounds (VOCs) emanating from the human body (the volatolome) is for the first time reported. 1840 VOCs have been assigned from breath (872), saliva (359), blood (154), milk (256), skin secretions (532) urine (279), and faeces (381) in apparently healthy individuals. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been grouped into tables according to their chemical class or functionality to permit easy comparison. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces. Careful use of the database is needed. The numbers may not be a true reflection of the actual VOCs present from each bodily excretion. The lack of a compound could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from blood compared to a large number on VOCs in breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. collecting excretions on glass beads and then heating to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors' intention that this database will not only be a useful database of VOCs listed in the literature, but will stimulate further study of VOCs from healthy individuals. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.
Collapse
Affiliation(s)
- B de Lacy Costello
- Institute of Biosensor Technology, University of the West of England, Bristol BS16 1QY, UK
| | | | | | | | | | | | | | | |
Collapse
|
8
|
|
9
|
Khalid TY, Saad S, Greenman J, de Lacy Costello B, Probert CSJ, Ratcliffe NM. Volatiles from oral anaerobes confounding breath biomarker discovery. J Breath Res 2013; 7:017114. [DOI: 10.1088/1752-7155/7/1/017114] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
10
|
De Lacy Costello B, Ewen R, Ewer AK, Garner CE, Probert CSJ, Ratcliffe NM, Smith S. An analysis of volatiles in the headspace of the faeces of neonates. J Breath Res 2008; 2:037023. [PMID: 21386183 DOI: 10.1088/1752-7155/2/3/037023] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A gas chromatography/mass spectrometry (GCMS) analysis of the headspace from the faeces of neonates was undertaken to record the volatiles associated with preterm babies on a neonatal unit. The compounds ethanol, acetone, 2-ethyl-1-hexanol, 3-methylbutanal, hexanal and 2,3-butanedione occurred with the highest frequency. The volatiles analysed were then compared to a previously published study of the volatiles from asymptomatic adult faeces. Fewer compounds were found in the neonatal faeces and virtually no sulfides were detected, in contrast to the adult samples where carbon disulfide, dimethyl disulfide and dimethyl sulfide were ubiquitous. In addition, 7 of the most abundant 15 volatile compounds were found to be aldehydes, while in contrast only 2, acetaldehyde and benzaldehyde, were present in the most abundant 15 compounds found in the headspace of adult faeces. 2-Ethyl-1-hexanol was considerably more abundant in the neonate stool compared to adult stool, and probably reflects high exposure to plastic materials containing plasticizers. The potential of disease diagnoses from the analysis of volatiles emitted from neonate faeces is discussed.
Collapse
Affiliation(s)
- B De Lacy Costello
- Centre for Research in Analytical, Material and Sensor Sciences, Coldharbour Lane, Frenchay, University of the West of England, Bristol, BS16 1QY, UK
| | | | | | | | | | | | | |
Collapse
|
11
|
de Lacy Costello BPJ, Ewen RJ, Ratcliffe NM, Richards M. The characteristics of novel low-cost sensors for volatile biomarker detection. J Breath Res 2008; 2:037017. [DOI: 10.1088/1752-7155/2/3/037017] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
12
|
Smith S, Burden H, Persad R, Whittington K, de Lacy Costello B, Ratcliffe NM, Probert CS. A comparative study of the analysis of human urine headspace using gas chromatography–mass spectrometry. J Breath Res 2008; 2:037022. [DOI: 10.1088/1752-7155/2/3/037022] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Costello BPJDL, Ewen RJ, Ratcliffe NM. A sensor system for monitoring the simple gases hydrogen, carbon monoxide, hydrogen sulfide, ammonia and ethanol in exhaled breath. J Breath Res 2008; 2:037011. [DOI: 10.1088/1752-7155/2/3/037011] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
de Lacy Costello BPJ, Sivanand PS, Ratcliffe NM, Reynolds DM. The rapid detection of methyl tert-butyl ether (MtBE) in water using a prototype gas sensor system. Water Sci Technol 2005; 52:117-23. [PMID: 16312958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The gasoline additive Methyl-tertiary-Butyl Ether (MtBE) is the second most common contaminant of groundwater in the USA and represents an important soil contaminant. This compound has been detected in the groundwater in at least 27 states as a result of leaking underground storage facilities (gasoline storage tanks and pipelines). Since the health effects of MtBE are unclear the potential threat to drinking water supplies is serious. Therefore, the ability to detect MtBE at low levels (ppb) and on-line at high-risk groundwater sites would be highly desirable. This paper reports the use of 'commercial' and metal oxide sensor arrays for the detection of MtBE in drinking and surface waters at low ppb level (microg.L(-1) range). The output responses from some of the sensors were found to correlate well with MtBE concentrations under laboratory conditions.
Collapse
Affiliation(s)
- B P J de Lacy Costello
- Centre for Research in Analytical Material and Sensor Sciences, Faculty of Applied Sciences, University of the West of England, Bristol, UK
| | | | | | | |
Collapse
|
15
|
Abstract
BACKGROUND The microbiological diagnosis of infectious diarrhoea may take several days using conventional techniques. In order to determine whether flatus can be used to make a rapid diagnosis, the volatile organic compounds associated with diarrhoea were analysed. METHODS Stool samples were collected from 35 patients with infectious diarrhoea and from six healthy controls. Gaseous compounds were extracted from a headspace using solid phase microextraction and analysed using gas chromatography and mass spectroscopy. RESULTS Characteristic patterns of volatile gases were found for the main causes of infectious diarrhoea in hospitals. Furan species without indoles indicated Clostridium difficile, ethyl dodecanoate indicated rotavirus, ammonia without ethyl dodecanoate suggested other enteric viruses, and the absence of hydrocarbons and terpenes indicated Campylobacter infection. CONCLUSION These results could be the basis of rapid near patient diagnosis of infectious diarrhoea.
Collapse
Affiliation(s)
- C S J Probert
- Department of Medicine, Bristol Royal Infirmary, Bristol, UK.
| | | | | |
Collapse
|
16
|
Honeychurch KC, Hart JP, Pritchard PRJ, Hawkins SJ, Ratcliffe NM. Development of an electrochemical assay for 2,6-dinitrotoluene, based on a screen-printed carbon electrode, and its potential application in bioanalysis, occupational and public health. Biosens Bioelectron 2003; 19:305-12. [PMID: 14615087 DOI: 10.1016/s0956-5663(03)00208-2] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Screen-printed carbon electrodes (SPCEs) have been successfully exploited as disposable sensors for the measurement of 2,6-dinitrotoluene (2,6-DNT) using a stripping voltammetric method. Initial investigations were undertaken using cyclic voltammetry (CV) to characterise the redox behaviour at the SPCEs. Further studies were then performed to deduce the optimum applied potential and accumulation time for the stripping voltammetric procedure. In addition, a study was carried out to ascertain whether small volumes of samples could be reliably used for analysis. From these studies it was shown that a 100 microl aliquot of sample could be analysed and the calibration plot was linear from 161 ng ml(-1) to 137 microg ml(-1) (R(2)=0.9991), the former concentration being the detection limit. The effects of the major components of human saliva at concentrations normally present were investigated. Of the individual components tested, only Cl(-) and albumen were found to interfere. The presence of the latter could be easily overcome by the addition of (NH(4))(2)SO(4). An interference study was also carried out on some inorganic and organic species that may be present in water samples. The sensors were evaluated by carrying out 2,6-DNT determinations on spiked and unspiked human saliva, dust wipe and potable water samples. Mean recoveries of 47.5, 73.4 and 102.4% were obtained; coefficients of variation of 7.88, 6.63 and 6.42% were calculated for a concentration of 9.1 microg ml(-1) in water, 10.6 microg ml(-1) saliva samples, and 141.1 ng cm(-2) for dust wipe samples, respectively. The performance characteristics show that the method holds promise and reliable data may be obtained for 2,6-DNT in bioanalysis and public health.
Collapse
Affiliation(s)
- K C Honeychurch
- Centre for Research in Analytical, Materials and Sensors Science, Faculty of Applied Sciences, University of the West of England, Frenchay Campus, Coldharbour Lane, Bristol BS16 1QY, UK
| | | | | | | | | |
Collapse
|
17
|
Guernion N, Ratcliffe NM, Spencer-Phillips PT, Howe RA. Identifying bacteria in human urine: current practice and the potential for rapid, near-patient diagnosis by sensing volatile organic compounds. Clin Chem Lab Med 2001; 39:893-906. [PMID: 11758602 DOI: 10.1515/cclm.2001.146] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Urinary tract infection (UTI) represents a significant burden for the National Health Service. Extensive research has been directed towards rapid detection of UTI in the last thirty years. A wide range of microbiological and chemical techniques are now available to identify and quantify bacteria in urine. However, there is a clear and present need for near, rapid, sensitive, reliable analytical methods, preferably with low-running costs, that could allow early detection of UTI and other diseases in urine. Here we review the "state of the art" of current practice for the detection of bacteria in urine and describe the advantages of the recent "e-nose" technology as a potential tool for rapid, near-patient diagnosis of UTI, by sensing volatile organic compounds (VOCs).
Collapse
Affiliation(s)
- N Guernion
- Faculty of Applied Sciences, University of the West of England, Bristol, UK
| | | | | | | |
Collapse
|
18
|
Blac M, Cowell DC, Penaul C, Ratcliffe NM, Spence R, Teare C. Ammonia vapour in the mouth as a diagnostic marker for Helicobacter pylori infection: preliminary 'proof of principle' pharmacological investigations. Br J Biomed Sci 2001; 58:66-75. [PMID: 11440209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
Most current non-invasive tests for Helicobacter pylori depend on the conversion of labelled (13C or 14C) urea to labelled carbon dioxide (13CO2 or 14CO2) and ammonium (NH4+) by the enzyme urease, with the labelled CO2 detected in exhaled air. Despite suggestions going back over a number of years, the alternative possibility of using NH4+ (in the form of gaseous ammonia [NH3]) as the test parameter has received little or no attention. However, this approach is now being explored using a chemiresistive sensor detecting sub-parts per million concentrations of NH3. An in vitro 'glass stomach' (containing various volumes of hydrochloric acid [HCl] and ammonium chloride [NH4Cl]) was used to evaluate the means of increasing 'gastric' pH to that of the NH4+-->NH3 transition that occurs significantly at pH 9.24. This 'stomach' also was used to study mechanisms by which NH3 may be expelled in a pulse (as a surrogate belch), either by the in situ production of CO2 or through an exogenous source. On the basis of the protocols developed, H. pylori-negative subjects were tested before and after ingestion of 10 mg NH4Cl (as a surrogate for bacteria-produced NH4,), and H. pylori-positive subjects were tested without taking urea or NH4Cl. 'Intragastric' pH in the in vitro 'glass stomach' could be increased above pH 9.24 by adding a mixture of 15-30 mL magnesium hydroxide mixture (or the proprietary equivalent) and 50 mL water, and the resulting NH3 expelled by adding 100 mL CO2-saturated cold water (sparkling water). In vivo, NH3 levels in the oral cavity of H. pylori-negative subjects were increased after ingestion of 10 mg NH4Cl; however, levels in the oral cavity of a small number of H. pylori-positive subjects were two- to threefold higher after magnesium hydroxide and sparkling water. On the basis of in vitro studies, an in vivo protocol was developed to increase gastric pH above that required for the NH4+-->NH3 transition, and a mechanism established to release the NH3 into the oral cavity. Preliminary in vivo data confirm the chemiresistive sensor is sufficiently sensitive to NH3 to distinguish H. pylori-negative subjects who have taken 10 mg NH4Cl from those who have not, and clearly distinguish H. pylori-negative subjects from H. pylori-positive subjects. Ingestion of urea or other labelled tracers is not required, nor is belching; and the sensor takes less than two minutes to reach a maximum response. The data provide good evidence that the chemiresistive detection of NH3 has considerable potential as a rapid, point-of-care diagnostic test for H. pylori infection.
Collapse
|