1
|
A practical approach to the theoretical models to calculate NO parameters of the respiratory system. J Breath Res 2014; 8:016002. [PMID: 24565997 DOI: 10.1088/1752-7155/8/1/016002] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Expired nitric oxide (NO) is used as a biomarker in different respiratory diseases. The recommended flow rate of 50 mL s⁻¹ (F(E)NO₀.₀₅) does not reveal from where in the lung NO production originated. Theoretical models of NO transfer from the respiratory system, linear or nonlinear approaches, have therefore been developed and applied. These models can estimate NO from distal lung (alveolar NO) and airways (bronchial flux). The aim of this study was to show the limitation in exhaled flow rate for the theoretical models of NO production in the respiratory system, linear and nonlinear models. Subjects (n = 32) exhaled at eight different flow rates between 10-350 mL s⁻¹ for the theoretical protocols. Additional subjects (n = 32) exhaled at tree flow rates (20, 100 and 350 mL s⁻¹) for the clinical protocol. When alveolar NO is calculated using high flow rates with the linear model, correction for axial back diffusion becomes negligible, -0.04 ppb and bronchial flux enhanced by 1.27. With Högman and Meriläinen algorithm (nonlinear model) the corrections factors can be understood to be embedded, and the flow rates to be used are ≤20, 100 and ≥350 mL s⁻¹. Applying these flow rates in a clinical setting any F(E)NO can be calculated necessitating fewer exhalations. Hence, measured F(E)NO₀.₀₅ 12.9 (7.2-18.7) ppb and calculated 12.9 (6.8-18.7) ppb. In conclusion, the only possibility to avoid inconsistencies between research groups is to use the measured NO values as such in modelling, and apply tight quality control to accuracies in both NO concentration and exhaled flow measurements.
Collapse
|
2
|
Abstract
There is still an unexplored potential for exhaled nitric oxide (NO) in many clinical applications. This study presents an overview of the currently available methods for monitoring NO in exhaled breath and the use of the modelling of NO production and transport in the lung in clinical practice. Three technologies are described, namely chemiluminescence, electrochemical sensing and laser-based detection with their advantages and limitations. Comparisons are made in terms of sensitivity, time response, size, costs and suitability for clinical purposes. The importance of the flow rate for NO sampling is discussed from the perspective of the recent recommendations for standardized procedures for online and offline NO measurement. The measurement of NO at one flow rate, such as 50 ml s(-1), can neither determine the alveolar site/peripheral contribution nor quantify the difference in NO diffusion from the airways walls. The use of NO modelling (linear or non-linear approach) can solve this problem and provide useful information about the source of NO. This is of great value in diagnostic procedures of respiratory diseases and in treatment with anti-inflammatory drugs.
Collapse
|
3
|
Diagnostic Ultrasound of Maxillary and Frontal Sinusitis — A new Simple Echoscope and Method. Acta Otolaryngol 2009. [DOI: 10.3109/00016488209108537] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
4
|
Abstract
BACKGROUND Dexmedetomidine, a selective alpha(2)-adrenoceptor agonist, induces a unique, sleep-like state of sedation. The objective of the present work was to study human electroencephalogram (EEG) sleep spindles during dexmedetomidine sedation and compare them with spindles during normal physiological sleep, to test the hypothesis that dexmedetomidine exerts its effects via normal sleep-promoting pathways. METHODS EEG was continuously recorded from a bipolar frontopolar-laterofrontal derivation with Entropy Module (GE Healthcare) during light and deep dexmedetomidine sedation (target-controlled infusions set at 0.5 and 3.2 ng/ml) in 11 healthy subjects, and during physiological sleep in 10 healthy control subjects. Sleep spindles were visually scored and quantitatively analyzed for density, duration, amplitude (band-pass filtering) and frequency content (matching pursuit approach), and compared between the two groups. RESULTS In visual analysis, EEG activity during dexmedetomidine sedation was similar to physiological stage 2 (S2) sleep with slight to moderate amount of slow-wave activity and abundant sleep spindle activity. In quantitative EEG analyses, sleep spindles were similar during dexmedetomidine sedation and normal sleep. No statistically significant differences were found in spindle density, amplitude or frequency content, but the spindles during dexmedetomidine sedation had longer duration (mean 1.11 s, SD 0.14 s) than spindles in normal sleep (mean 0.88 s, SD 0.14 s; P=0.0014). CONCLUSIONS Analysis of sleep spindles shows that dexmedetomidine produces a state closely resembling physiological S2 sleep in humans, which gives further support to earlier experimental evidence for activation of normal non-rapid eye movement sleep-promoting pathways by this sedative agent.
Collapse
|
5
|
Abstract
The discovery of the flow dependence of exhaled NO made it possible to model NO production in the lung. The linear model provides information about the maximal flux of NO from the airways and the alveolar concentrations of NO. Nonlinear models give additional flow-independent parameters such as airway diffusing capacity and airway wall concentrations of NO. When these models are applied to patients with asthma, a clear-cut increase in NO flux is found, and this is caused by an increase in both airway diffusing capacity and airway wall concentrations of NO. There is no difference in alveolar concentrations of NO compared to healthy subjects, except in severe asthma where an increase has been found. Inhaled corticosteroids are able to reduce the airway wall concentrations but not diffusing capacity or alveolar concentrations. Oral prednisone affects the alveolar concentration, suggesting that in severe asthma there is a systemic component. Steroids distributed by any route do not affect the airway diffusing capacity. Therefore, the airway diffusing capacity should be in focus in testing new drugs or in combination treatment for asthma. Exhaled NO analysis is a promising tool in characterizing asthma in both adults and children. However, there is a strong need to agree on the models and to standardize the flow rates to be used for the modelling in order to perform a systematic and robust analysis of NO production in the lung.
Collapse
|
6
|
ICS Free Paper Presentation (Research) Winner. J Intensive Care Soc 2007. [DOI: 10.1177/175114370700800118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
7
|
Abstract
BACKGROUND Inadequate analgesia during general anaesthesia may present as undesirable haemodynamic responses. No objective measures of the adequacy of analgesia exist. We aimed at developing a simple numerical measure of the level of surgical stress in an anaesthetized patient. METHODS Sixty and 12 female patients were included in the development and validation data sets, respectively. All patients had elective surgery with propofol-remifentanil target controlled anaesthesia. Finger photoplethysmography and electrocardiography waveforms were recorded throughout anaesthesia and various waveform parameters were extracted off-line. Total surgical stress (TSS) for a patient was estimated based on stimulus intensity and remifentanil concentration. The surgical stress index (SSI) was developed to correlate with the TSS estimate in the development data set. The performance of SSI was validated within the validation data set during and before surgery, especially at skin incision and during changes of the predicted remifentanil effect-site concentration. RESULTS SSI was computed as a combination of normalized heart beat interval (HBI(norm)) and plethysmographic pulse wave amplitude (PPGA(norm)): SSI = 100-(0.7*PPGA(norm)+0.3*HBI(norm)). SSI increased at skin incision and stayed higher during surgery than before surgery; SSI responded to remifentanil concentration changes and was higher at the lower concentrations of remifentanil. CONCLUSIONS SSI reacts to surgical nociceptive stimuli and analgesic drug concentration changes during propofol-remifentanil anaesthesia. Further validation studies of SSI are needed to elucidate its usefulness during other anaesthetic and surgical conditions.
Collapse
MESH Headings
- Adult
- Aged
- Analgesics, Opioid/administration & dosage
- Anesthesia, General/methods
- Anesthetics, Combined/administration & dosage
- Anesthetics, Intravenous/administration & dosage
- Dose-Response Relationship, Drug
- Electrocardiography/drug effects
- Female
- Heart Rate/drug effects
- Humans
- Intraoperative Complications/diagnosis
- Middle Aged
- Models, Neurological
- Monitoring, Intraoperative/methods
- Photoplethysmography
- Piperidines/administration & dosage
- Propofol/administration & dosage
- Remifentanil
- Severity of Illness Index
- Signal Processing, Computer-Assisted
- Stress, Physiological/diagnosis
- Stress, Physiological/etiology
Collapse
|
8
|
P36.22 EEG entropy in assessment of the depth of natural sleep in healthy volunteers. Clin Neurophysiol 2006. [DOI: 10.1016/j.clinph.2006.06.632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Abstract
It is a well-known fact that smoking is associated with a reduction in exhaled nitric oxide (NO) levels. There is, however, limited knowledge relating to the smoking-induced changes in production or exchange of NO in different compartments of the airways. This study comprised 221 adult subjects from the European Community Respiratory Health Survey II, who were investigated in terms of their exhaled NO, lung function, immunoglobulin E sensitisation and smoking habits. The following parameters were determined using extended NO analysis: airway tissue nitric oxide concentration (Caw,NO), airway transfer factor (or diffusing capacity) for nitric oxide (Daw,NO), alveolar nitric oxide concentration (CA,NO) and fractional exhaled nitric oxide concentration at a flow rate of 50 mL x s(-1) (FeNO,0.05). Maximum total airway nitric oxide flux (J'aw,NO) was calculated from Daw,NO(Caw,NO-CA,NO). Current smokers (n = 35) exhibited lower (geometric mean) FeNO,0.05 (14.0 versus 22.8 ppb), Caw,NO (79.0 ;versus 126 ppb) and J'aw,NO (688 versus 1,153 pL x s(-1)) than never-smokers (n = 111). Ex-smokers (n = 75) were characterised by lower FeNO,0.05 (17.7 versus 22.8 ppb) and Jaw,NO (858 versus 1,153 pL x s(-1)) than never-smokers. These relationships were maintained after adjusting for potential confounders (sex, age, height, immunoglobulin E sensitisation and forced expiratory volume in one second), and, in this analysis, a negative association was found between current smoking and CA,NO. Snus (oral moist snuff) consumption (n = 21) in ex-smokers was associated with an increase in Daw,NO and a reduction in Caw,NO, after adjusting for potential confounders. Passive smoking was associated with a higher CA,NO. Using extended nitric oxide analysis, it was possible to attribute the reduction in exhaled nitric oxide levels seen in ex- and current smokers to a lower total airway nitric oxide flux in ex-smokers and reduced airway and alveolar nitric oxide concentrations in current smokers. The association between snus (oral tobacco) use and reduced nitric oxide concentrations in the airways and increased nitric oxide transfer from the airways warrants further studies.
Collapse
|
10
|
Viertiö-oja H, Lapinlampi P, Särkelä M, Meriläinen P, Ramsay P, Walsh T. Crit Care 2006; 10:P442. [DOI: 10.1186/cc4789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
11
|
|
12
|
Abstract
BACKGROUND Pulsed administration of nitric oxide has proven effective in relieving pulmonary hypertension and in improving oxygenation. With this delivery method the nitric oxide administration to low ventilated lung regions is avoided with subsequent enhancement in oxygenation. This study presents (i) pulsed administration technique for nitric oxide during artificial ventilation, (ii) evaluation of the delivery in an animal model, and (iii) validation of the delivery device in a laboratory setting. METHODS Nitric oxide was delivered in four different pulse volumes synchronously with inspiration. The delivery was monitored with a fast responding high sensitivity nitric oxide monitor and nitric oxide uptake was calculated. Pulse delivery dose range, accuracy of the delivered dose, and stability of successive doses were analysed in a laboratory setting. RESULTS Uptake of the delivered nitric oxide was 87-92%. Measured nitric oxide pulse concentration was 1.6-fold the delivery concentration, calculated as the ratio of nitric oxide flow to inspiration flow. Dose accuracy and stability were both 5% or 3 nmol in the validated range of 3-1000 nmol. CONCLUSION With pulsed administration nitric oxide therapy can be directed to well-ventilated lung regions. Avoiding administration to the anatomic dead space eliminates nitric oxide exhalation effectively, which makes the method optimal for nitric oxide therapy in a rebreathing circuit. The required dose range from paediatric to adult is covered by the delivery device with a single nitric oxide gas supply.
Collapse
|
13
|
Abstract
Smokers have been found to have low exhaled nitric oxide (NO) levels. The aim of the present study was to investigate where in the respiratory system the decrease in NO occurs, and whether this decrease was affected by smoking cessation. Measurements of exhaled NO were carried out in smokers (n=20) and non-smoking control subjects (n=30). In nine of the smokers, exhaled NO was analysed 1, 2 and 4 weeks after smoking cessation. The level of exhaled NO at a flow rate of 0.1 litre/s was significantly lower in smokers (4+/-2 p.p.b.) than in non-smokers (7+/-5 p.p.b.; P=0.007). A calculation of the contributions from different areas of the lung showed that the NO flux from the airways was significantly lower (14+/-10 compared with 36+/-26 nl/min; P=0.0001) and the alveolar fraction was significantly higher (2.1+/-0.8 compared with 1.5+/-0.9 p.p.b.; P=0.006) in smokers than in non-smokers. Nine smoking subjects refrained from smoking for 4 weeks, and this resulted in increased NO flux from the airways of 28+/-17 nl/min, which was no longer significantly different from controls. In conclusion, endogenous production of NO in the airways is decreased in smokers, but can be restored to normal values by 4 weeks after cessation of smoking. Smokers have an increased alveolar fraction of NO, and this might be a diagnostic sign of lung damage. Thus NO monitoring can be used to indicate improvements when a smoker decides to stop smoking.
Collapse
|
14
|
Effect of different pulses of nitric oxide on venous admixture in the anaesthetized horse. Br J Anaesth 2002; 88:394-8. [PMID: 11990273 DOI: 10.1093/bja/88.3.394] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Dependent atelectatic lung areas open towards the end of inspiration when the lung opening pressure increases, and recollapse during expiration. We hypothesized that inhaled nitric oxide (NO) counteracts hypoxic vasoconstriction in these collapsing lung areas, resulting in increased pulmonary shunt perfusion. METHODS We administered NO as a pulse and varied the pulse timing during inspiration in equine anaesthesia, where atelectasis develops regularly. Six spontaneously breathing standard breed trotters were studied under isoflurane anaesthesia in lateral recumbency. NO pulsed into the first 30% of inspiration (group NOp1) was assumed to affect open lung areas. To cover more open lung areas NO was then pulsed into the first 60% of inspiration (group NOp2). In a third group, administration between 50 and 80% of inspiration was aimed at the intermittently opening lung areas (group NOp3). RESULTS With NOp1, venous admixture decreased by 8 (2)% (mean (SEM), P=0.045) and with NOp2 by 10 (1)% (P=0.01). With NOp3, venous admixture reduction was insignificant. CONCLUSIONS Pulsed administration of NO in early inspiration is optimal in reducing right to left vascular shunt in atelectatic equine lung. This reduction is positively correlated with the magnitude of the initial shunt. With administration in early inspiration, NO is mostly taken up by the lung. This prevents NO accumulation and NO2 formation in rebreathing circuits. These findings may be important in humans when atelectasis occurs increasingly with overweight and age during anaesthesia, but also in postoperative intensive care and in ARDS.
Collapse
|
15
|
Abstract
The recommended method to measure exhaled nitric oxide (NO) cannot reveal the source of NO production. We applied a model based on the classical Fick's first law of diffusion to partition NO in the lungs. The aim was to develop a simple and robust solution algorithm with a data quality control feature, and apply it to patients with known alterations in exhaled NO. Subjects with allergic rhinitis, allergic asthma, chronic obstructive pulmonary disease (COPD) smokers and controls were investigated. NO was measured at three expiratory flow rates. An iteration method was developed to partition NO. The airway tissue content of NO was increased in asthma, 144 +/- 80 ppb (P = 0.04) and decreased in smokers, 56 +/- 36 ppb (P = 0.02). There was no difference between subjects with rhinitis, 98 +/- 40 ppb and controls, 98 +/- 44 ppb. The airway transfer rate was increased in allergic asthma and allergic rhinitis, 12 +/- 4 vs. 12 +/- 5 ml sec(-1), compared to controls, 8 +/- 2 ml sec(-1) (P < 0.001). The alveolar levels were no different from controls, 2 +/- 1 ppb. In COPD the alveolar levels were increased, 4 +/- 2 ppb (P < 0.001). Extended NO analysis reveals from where in the respiratory system NO is generated. Hence, this new test can be added to the tools the physician has for the diagnosis and treatment of patients with respiratory disorders.
Collapse
|
16
|
Abstract
This study is an evaluation of a project in Finland that aimed to promote the participation of informal caregivers in the hospital care of elderly patients. The staff who worked in the wards that were studied built up activation programmes for informal caregivers, and changed ward policies to encourage caregivers' participation. To explore changes in caregivers' participation in the study and the control wards, non-equivalent control groups were used. During periods of two months in 1991, 1992 and 1993, the data were collected from informal caregivers (N = 369) using a structured questionnaire. The results indicated that total participation of informal caregivers in daily activities increased in long-term care settings, but not in the university hospital. However, a small increase in informal caregivers' participation in some daily activities of elderly patients took place in the study wards of each setting. The findings and implications for nursing are discussed.
Collapse
|
17
|
Inhaled mannitol shifts exhaled nitric oxide in opposite directions in asthmatics and healthy subjects. RESPIRATION PHYSIOLOGY 2001; 124:141-50. [PMID: 11164205 DOI: 10.1016/s0034-5687(00)00195-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
We investigated if healthy subjects could release NO upon hyperosmolar challenge as a defence mechanism, and whether asthmatics with atopy showed an altered response. A plot of NO output versus flow rate was used to calculate the alveolar level and the NO-flux from the airways. The asthmatics had a higher NO output and this was due to an increased NO-flux from the airways, 86+/-30 nl min(-1) compared with control 21+/-2 nl min(-1) (P<0.05). The alveolar NO levels showed no difference. In response to a dry powder of mannitol the exhaled NO concentration decreased in asthmatics by 37+/-7%, but increased in the control by 9+/-4% (P<0.001). The FEV(1.0) decreased 13+/-2% and airway conductance 42+/-7% in asthmatics and in the controls 2+/-1% and 0+/-7%, respectively (P<0.001). We conclude that asthmatics have an altered response to mannitol challenge in regards to exhaled NO. This may result from down regulation of constitutive NO production as a result of high levels of NO flux from the airways.
Collapse
|
18
|
Abstract
During the last year exhaled nitric oxide (NO) has been proposed as a marker of airway inflammation. More knowledge of the production and transfer of this molecule are needed in order for NO analysis to become a clinical tool. This was the aim of the study. Exhaled NO values from multiple flow rates were used to model alveolar NO, transfer rate and tissue concentration of NO in the airways. Three flows rates, 0.005, 0.1 and 0.51 sec(-1) were found to be optimal. The NO transfer rate of the airways was 9 +/- 2 ml sec(-1), the tissue source was 75 +/- 28 ppb and the alveolar fraction of NO was 2 +/- 1 ppb in 10 healthy subjects (mean +/- CI95%). In conclusion, we have shown that it is possible to get more information about the distribution of NO in the lungs and the airways than only a single value from one expiratory flow rate can give. Further studies will reveal if this airway modelling can be useful in disease of the respiratory system.
Collapse
|
19
|
Theoretical and experimental comparison of constant inspired concentration and pulsed delivery in NO therapy. Intensive Care Med 2000; 26:1116-23. [PMID: 11030169 DOI: 10.1007/s001340051326] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Inhaled NO therapy of artificially ventilated patients has been established as being based on constant inspired concentration of NO. In this study a new volumetrically controlled pulsed NO delivery mode is compared with the established concentration-based concept. DESIGN To evaluate the relationship between NO delivery parameters, alveolar NO fraction, and patient uptake, a mathematical lung model was created where NO delivery can be simulated in varying ventilator settings, delivery modes, and lung properties. This model and the efficacy of pulsed delivery in inducing pulmonary capillary vasodilatation were examined experimentally. SETTING Animal laboratory, Department of Medical Sciences, Clinical Physiology. SUBJECTS The experimental study was performed with nine pigs of mixed breed weighing 25-35 kg. INTERVENTIONS The pigs were anaesthetised and artificially ventilated. Pulmonary vasoconstriction was induced by hypoxia. NO was delivered periodically in the various delivery modes. MEASUREMENTS AND RESULTS In simulation, in all delivery modes the NO uptake was found to be dependent on the ventilator settings and the volume of the dead space. Measured from pulmonary artery pressure, the pulsed delivery was as effective in reducing the induced pulmonary vasoconstriction as the constant inspired concentration delivery. The amount of NO that could reduce the vasoconstriction back to baseline was 105 nmol x min(-1). By delivering in the early part of the inspiration, ambient contamination by the exhaust gas is avoided. The expired NO values obtained in the simulation and the experiments were equal. Based on the simulation, the alveolar NO fraction and the NO uptake depend on the ventilator settings and the dead space in both volumetric- and concentration-based delivery. CONCLUSIONS With pulsed delivery, a therapeutic effect comparable to constant inspired concentration delivery is achieved, NO gas is used more effectively, and environmental exhausts are reduced. The theoretical model shows that the NO delivery does not predict alveolar NO fraction and the NO uptake. However, it still remains an open question if the online measurement of these parameters would provide useful information, having added value in predicting and controlling the efficacy of the NO treatment.
Collapse
|
20
|
[Methods used in the hospital for patients' sleep improvement]. HOITOTIEDE 1999; 10:289-98. [PMID: 10437452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
The purpose of this article is to describe methods used in the hospital for sleep improvement. The article is based on a study of patients' sleep in a Finnish hospital's medical or surgical ward. The patients of the Central Hospital of Northern Carelia's two medical and two surgical wards took part in the research. The data were collected by a structured questionnaire in May-June 1996. Of the replies of 181 patients, the results of 177 were taken to the final analysis. The data were analysed by statistical methods. The data and the results are presented in frequency and percent distributions. The most common method used by the patients to improve their sleep was to choose a good sleeping position. Other methods, which were often used, were reading, watching TV, having a snack, taking a warm shower or praying. The nurses were versatile in using the available methods of nursing for helping the patients to sleep. They informed the patients about their illnesses, nursing regime and the forthcoming operations, consoling and giving support to them. The nurses also organised sleep-supporting environment and gave painkillers and sleeping pills. About 60% of the researched patients were of the opinion, that sleeping tablets were prescribed too often. The patients themselves regarded the information and knowledge about their own treatment as the best way to improve their sleep.
Collapse
|
21
|
[Sleep disturbances affecting hospital patients]. HOITOTIEDE 1999; 10:134-43. [PMID: 10437442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
The purpose of this article is to describe patients' sleep in hospital. The article is based on a study of patients' sleep in a hospital's medical or surgical ward and to clarify the disturbance factors relating to their sleep. The patients of the Central Hospital of Northern Carelia's two medical and two surgical wards took part in the research. The data were collected by a structured questionnaire and a follow-up questionnaire in May-June 1996. Of the replies of 181 patients, the results of 177 were taken to the final analysis. The data were analysed by statistical methods. The data and the results are presented in frequency and percent distributions, and the background variables of those patients sleeping well and those sleeping poorly are analysed and compared. The results indicated that 65% of the researched patients slept badly in the hospital. Environmental factors were found to be related to most of the patients' sleep disturbances: 80% of them regarded those factors as the cause for their disturbed sleep. Other patients, noise, and the nurses' work were regarded as the most disturbing of the environmental factors. The internal factors had disturbed patients' sleep in the hospital less than the environmental factors. Pain was regarded as the most sleep disturbing internal factor: over half of the researched patients felt disturbed by it. During their stay in the hospital the patients experienced more positive (trust, contentment, safety) than negative feelings (fear, anxiety, depression, distrust), and those who experienced negative feelings had more difficulties in sleeping.
Collapse
|
22
|
Error in measurement of oxygen and carbon dioxide concentrations by the DeltatracII metabolic monitor in the presence of desflurane. Br J Anaesth 1998; 80:521-4. [PMID: 9640164 DOI: 10.1093/bja/80.4.521] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
In experiments in dogs on the metabolic effects of inhalation anaesthetics, we noticed that in the presence of desflurane, oxygen uptake (VO2) measured with the Deltatracll metabolic monitor seemingly increased whereas it decreased when determined independently by the Fick principle. This difference remained even after correction for changes in gas concentration on addition of an inhalation anaesthetic. Therefore, we suspected that desflurane interferes with the measurement of gas concentrations. Using different precision gases, we found that desflurane disturbed both the paramagnetic oxygen sensor and the infrared carbon dioxide detector so that the measured oxygen (when FIO2 was > 0.21) and carbon dioxide concentrations were greater than expected. These errors multiply in the computing process of oxygen uptake by the DeltatracII. When the DeltatracII is to be used during inhalation anaesthesia, its results should be corrected for the presence of an anaesthetic gas. More importantly, corrections must also be made for measurement errors of the oxygen and carbon dioxide sensors, unless the device has been equipped with a modified (nickel membrane) oxygen sensor insensitive to the presence of volatile agents.
Collapse
|
23
|
Abstract
This study is part of a project that aimed to increase the participation of informal caregivers in the hospital care for elderly patients. The staff who worked in the wards that were studied created activity programmes for caregivers and changed their ward policies to encourage the participation of the caregivers. In addition, quality assurance programmes were developed and primary nursing was introduced to ensure individualized, need-based and family centered care. In order to explore the changes in perceived quality of care, and to test the differences in care quality between the study and the control wards (i.e. two wards in a university hospital, two wards in a geriatric unit and two wards of a nursing home), the interrupted time series with a non-equivalent control group time series design was used. During periods of 2 months in 1991, 1992 and 1993 the data were collected from elderly patients (n = 97) and their informal caregivers (n = 369) using a structured questionnaire based on need theories. The results indicated that the quality of care was improved, especially in the study wards of the university hospital and of the nursing home. This care quality measure was found to be a useful tool for getting feedback from patients and their caregivers concerning care given. Aspects of nursing practice that needed to be improved were identified (i.e. poor communication between the patient, their caregiver and staff, and lack of support to the patient and caregiver by staff).
Collapse
|
24
|
Abstract
Measurement of gas flow and airway pressure at the Y-piece of an endotracheal tube provides valuable information about airway integrity and basic pulmonary function. We describe the working principle and design of the D-lite sensor (Datex Division, Instrumentarium Corporation, Helsinki, Finland), which, in a single, lightweight adapter piece, encloses flow, airway pressure, and sidestream gas measurement. The main emphasis in the design of this instrument was on reliable and accurate operation during continuous monitoring with exposure to humidity and mucus. Therefore, a robust flow-restrictor element with a pick-off arrangement resembling a Pitot tube was employed. This arrangement has nonlinear characteristics with potential difficulties in the measurement of small flows. However, these inherent drawbacks, together with compensations required because of varying gas fractions and pressure, can be handled by sophisticated computer algorithms at the host-monitor end (Capnomac Ultima [Datex Division, Instrumentarium Corporation, Helsinki, Finland]). Validation methods with main results and a brief review of applications are given.
Collapse
|
25
|
The Electronic Spectra of Thioamides and Thiohydrazides. Part I. LCAO-MO Treatment and Band Classification for Thiobenzamides. ACTA ACUST UNITED AC 1962. [DOI: 10.3891/acta.chem.scand.16-1616] [Citation(s) in RCA: 57] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|