1
|
Normative 3D gait data of healthy adults walking at three different speeds on an instrumented treadmill in virtual reality. Data Brief 2024; 53:110230. [PMID: 38445200 PMCID: PMC10912446 DOI: 10.1016/j.dib.2024.110230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 02/10/2024] [Accepted: 02/15/2024] [Indexed: 03/07/2024] Open
Abstract
A normative gait dataset of 246 healthy adults (122 men / 124 women, range in age 18-91 years, body weight 46.80-116.10 kg, height 1.53-1.97 m and BMI 18.25-35.63 kg/m2) is presented and publicly shared for three walking speed conditions. Raw and processed data are presented for each subject separately and for each walking speed, including data of every single step of both legs. The subject demographics and results from the physical examination are also presented which allows researchers and clinicians to create a self-selected reference group based on specific demographics. Besides the data per individual, data are also presented in age and gender groups. This provides a quick overview of healthy gait parameters which is relevant for use in clinical practice. Three dimensional gait analysis was performed at the Computer Assisted Rehabilitation Environment (CAREN) at the Maastricht University Medical Centre (MUMC+). Subjects walked on the instrumented treadmill surrounded with twelve 3D cameras, three 2D cameras and a virtual industrial environment projected on a 180° screen using the Human Body Lower Limb Model with trunk markers (HBM-II) as biomechanical model [1], [2]. Subjects walked at comfortable walking speed, 30% slower and 30% faster. These walking speed conditions were applied in a random sequence. Comfortable walking speed was determined using a RAMP protocol: subjects started to walk at 0.5m/s and every second the speed was increased with 0.01 m/s until the preferred speed was reached. The average of three repetitions was considered the comfortable speed. For each walking speed condition, 250 steps were recorded. The 3D gait data was collected using the D-flow CAREN software. For each subject, raw data of each walking speed condition is provided in .mox files, including the output from the model such as subject data (e.g. gender, body mass, knee and ankle width), center of mass (CoM), marker and force data, kinematic data (joint angles) and kinetic data (joint moments, ground reaction forces (GRFs) and joint powers) for each single step of both legs. Unfiltered and filtered data are included. C3D files with raw marker and GRF data were recorded in Nexus (Vicon software, version 2.8.1) and are available upon request. Raw data were processed in Matlab (Mathworks 2016), including quality check, step determination and the exportation of data to .xls files. For each adult and for each walking speed, an .xls file was created, containing spatiotemporal parameters, medio-lateral (ML) and back-forward (BF) margins of stability (MoS), 3D joint angles, anterior-posterior (AP) and vertical GRFs, 3D joint moments and 3D joint power of each step of both legs. Overview files per walking speed condition are created in .xls, presenting the averaged gait parameters (calculated as average over all valid steps) of every subject. The processed data is also presented and visualized per gender for different age groups (18-29 years, 30-39 years, 40-49 years, 50-59 years, 60-69 years, ≥70 years). This can serve as normative data for treadmill based 3D gait analyses in adults, applicable for clinical and research purposes. Data is available at OSF.io (https://osf.io/t72cw/).
Collapse
|
2
|
Gait alterations in patients with adult spinal deformity. NORTH AMERICAN SPINE SOCIETY JOURNAL 2024; 17:100306. [PMID: 38293567 PMCID: PMC10825775 DOI: 10.1016/j.xnsj.2023.100306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 12/18/2023] [Accepted: 12/26/2023] [Indexed: 02/01/2024]
Abstract
Background Adult spinal deformity patients (ASD) experience altered spinal alignment affecting spatiotemporal parameters and joint kinematics. Differences in spinal deformity between patients with symptomatic idiopathic scoliosis (ID-ASD) and patients with "de novo" scoliosis (DN-ASD) may affect gait characteristics differently. This study aims to compare gait characteristics between ID-ASD, DN-ASD, and asymptomatic healthy matched controls. Methods In this observational case-control study, ID-ASD (n = 24) and DN-ASD (n = 26) patients visiting the out-patient spine clinic and scheduled for long-segment spinal fusion were included. Patients were matched, based on age, gender, leg length and BMI, with asymptomatic healthy controls. Gait was measured at comfortable walking speed on an instrumented treadmill with 3D motion capture system. Trunk, pelvic and lower extremities range of motion (ROM) and spatiotemporal parameters (SPT) are presented as median (first and thirds quartile). Independent t-test or Mann-Whitney U test was used to compare ID-ASD, DN-ASD and controls. Statistical Parametric Mapping (independent t-test) was used to compare 3D joint kinematics. Results DN-ASD patients walk with increased anterior trunk tilt during the whole gait cycle compared with ID-ASD patients and controls. ID-ASD walk with decreased trunk lateroflexion compared with DN-ASD and controls. DN-ASD showed decreased pelvic obliquity and -rotation, increased knee flexion, and decreased ankle plantar flexion. ID-ASD and DN-ASD displayed decreased trunk, pelvic and lower extremity ROM compared with controls, but increased pelvic tilt ROM. ID-ASD patients walked with comparable SPT to controls, whereas DN-ASD patients walked significantly slower with corresponding changes in SPT and wider steps. Conclusions DN-ASD patients exhibit distinct alterations in SPT and kinematic gait characteristics compared with ID-ASD and controls. These alterations seem to be predominantly influenced by sagittal spinal malalignment and kinematic findings in ASD patients should not be generalized as such, but always be interpreted with consideration for the nature of the ASD.
Collapse
|
3
|
Patient with knee osteoarthritis demonstrates improved knee adduction moment after knee joint distraction: a case report. Acta Orthop Belg 2024; 90:147-153. [PMID: 38669666 DOI: 10.52628/90.1.11515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2024]
Abstract
In this article we report a case of a 53-year-old patient diagnosed with end-stage osteoarthritis (OA) of the knee. The patient underwent treatment with knee joint distraction (KJD) with the aim to postpone total knee arthroplasty and prevent potential revision surgery. To assess the effect of KJD, a 3D gait analysis was performed preoperative and one year postoperative. In this patient, preoperative 3D gait analysis revealed an increased knee adduction moment (KAM) compared to healthy levels. Postoperative the KAM decreased, approaching healthy levels, suggesting potential improvements in disease status or in gait. Consequently, further investigation into the effectiveness of Knee Joint Distraction (KJD) as a treatment option for relatively young patients with knee OA is warranted. Gait analysis has emerged as an effective tool for assessing treatment outcomes of innovative treatment such as KJD at the individual level.
Collapse
|
4
|
The Effect of a Smartphone App with an Accelerometer on the Physical Activity Behavior of Hospitalized Patients: A Randomized Controlled Trial. SENSORS (BASEL, SWITZERLAND) 2023; 23:8704. [PMID: 37960404 PMCID: PMC10648825 DOI: 10.3390/s23218704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 10/13/2023] [Accepted: 10/19/2023] [Indexed: 11/15/2023]
Abstract
Inactive behavior is common in hospitalized patients. This study investigated the effectiveness of using a smartphone app with an accelerometer (Hospital Fit) in addition to usual care physiotherapy on increasing patients' physical activity (PA) behavior. A randomized controlled trial was performed at Maastricht University Medical Centre. Patients receiving physiotherapy while hospitalized at the department of Pulmonology or Internal Medicine were randomized to usual care physiotherapy or using Hospital Fit additionally. Daily time spent walking, standing, and upright (standing/walking) (min) and daily number of postural transitions were measured with an accelerometer between the first and last treatment. Multiple linear regression analysis was performed to determine the association between PA behavior and Hospital Fit use, corrected for functional independence (mILAS). Seventy-eight patients were included with a median (IQR) age of 63 (56-68) years. Although no significant effects were found, a trend was seen in favor of Hospital Fit. Effects increased with length of use. Corrected for functional independence, Hospital Fit use resulted in an average increase of 27.4 min (95% CI: -2.4-57.3) standing/walking on day five and 29.2 min (95% CI: -6.4-64.7) on day six compared to usual care. Hospital Fit appears valuable in increasing PA in functionally independent patients.
Collapse
|
5
|
Dataset of 3D gait analysis in typically developing children walking at three different speeds on an instrumented treadmill in virtual reality. Data Brief 2023; 48:109142. [PMID: 37113500 PMCID: PMC10126839 DOI: 10.1016/j.dib.2023.109142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 03/17/2023] [Accepted: 04/04/2023] [Indexed: 04/29/2023] Open
Abstract
In this article, gait data of typically developing (TD) children (24 boys/31 girls, mean (95% confidence interval) age 9.38 (8.51 - 10.25) years, body mass 35.67 (31.40 - 39.94) kg, leg length 0.73 (0.70 - 0.76) m, and height 1.41 (1.35 - 1.46) m) walking at different walking speeds is shared publicly. Raw and processed data is presented for each child separately and includes data of each single step of both legs. Beside, the subject demographics and the results from the physical examination are presented allowing to select TD children from the database to create a matched group, based on specific parameters (e.g. sex and body weight). For clinical application, gait data is also presented per age group, which provides quick insight into the normal gait pattern of TD children of varying age. Gait analysis was performed during treadmill walking in a virtual environment using the Computer Assisted Rehabilitation Environment (CAREN). The human body lower limb model with trunk markers (HBM2) was used as biomechanical model. Children walked at comfortable walking speed, 30% slower and 30% faster (random sequence) while wearing gymnastic shoes and a safety harness to prevent falling. For each speed condition, 250 steps were recorded. Data quality check, step detection and the calculation of gait parameters was done by custom made Matlab algorithms. Raw data files are provided per walking speed, for each child separately. The raw data is exported from the CAREN software (D-flow) and is provided in .mox and .txt files. It includes the output from the models such as subject data, marker and force data, kinematic data (joint angles), kinetic data (joint moments, GRFs, joint powers), as well as CoM data and EMG data (the last two are not described in this manuscript), for each speed condition and each child. Unfiltered and filtered data are included. C3D files with raw marker and GRF data were recorded in Nexus (Vicon software) and are available upon request. After analyzing the raw data into Matlab (R2016a, Mathworks) using custom made Matlab algorithms, processed data is obtained. The processed data is provided in .xls files and is also presented for each child separately. It contains spatiotemporal parameters, 3D joint angles, anterior-posterior and vertical ground reaction forces (GRF), 3D joint moments and sagittal joint power of each step of the left and right leg. In addition to each individual's data, overview files (.xls) are created per walking speed condition. These overviews present the averaged gait parameter (e.g. joint angle), calculated over all valid steps, of each child.
Collapse
|
6
|
The effect of perturbation-based balance training on balance control and fear of falling in older adults: a single-blind randomised controlled trial. BMC Geriatr 2023; 23:305. [PMID: 37198543 DOI: 10.1186/s12877-023-03988-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 04/22/2023] [Indexed: 05/19/2023] Open
Abstract
BACKGROUND Perturbation-based balance training (PBT) is an emerging intervention shown to improve balance recovery responses and reduce falls in everyday life in older adults. However, perturbation interventions were heterogeneous in nature and need improvement. This study aims to investigate the effects of a PBT protocol that was designed to address previously identified challenges of PBT, in addition to usual care, on balance control and fear of falling in older adults at increased risk of falling. METHODS Community-dwelling older adults (age ≥ 65 years) who visited the hospital outpatient clinic due to a fall incident were included. Participants received PBT in addition to usual care (referral to a physiotherapist) versus usual care alone. PBT consisted of three 30-minute sessions in three weeks. Unilateral treadmill belt accelerations and decelerations and platform perturbations (shifts and tilts) were applied during standing and walking on the Computer Assisted Rehabilitation Environment (CAREN, Motek Medical BV). This dual-belt treadmill embedded in a motion platform with 6 degrees of freedom is surrounded by a 180° screen on which virtual reality environments are projected. Duration and contents of the training were standardised, while training progression was individualised. Fear of falling (FES-I) and balance control (Mini-BESTest) were assessed at baseline and one week post-intervention. Primary analysis compared changes in outcome measures between groups using Mann-Whitney U tests. RESULTS Eighty-two participants were included (PBT group n = 39), with a median age of 73 years (IQR 8 years). Median Mini-BESTest scores did not clinically relevantly improve and were not significantly different between groups post-intervention (p = 0.87). FES-I scores did not change in either group. CONCLUSIONS Participation in a PBT program including multiple perturbation types and directions did not lead to different effects than usual care on clinical measures of balance control or fear of falling in community-dwelling older adults with a recent history of falls. More research is needed to explore how to modulate PBT training dose, and which clinical outcomes are most suitable to measure training effects on balance control. TRIAL REGISTRATION Nederlands Trial Register NL7680. Registered 17-04-2019 - retrospectively registered. https://www.trialregister.nl/trial/7680 .
Collapse
|
7
|
Comparison of sagittal plane gait characteristics between the overground and treadmill approach for gait analysis in typically developing children. PeerJ 2022; 10:e13752. [PMID: 35898943 PMCID: PMC9310770 DOI: 10.7717/peerj.13752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 06/28/2022] [Indexed: 01/17/2023] Open
Abstract
Background Instrumented treadmills have become more mainstream in clinical assessment of gait disorders in children, and are increasingly being applied as an alternative to overground gait analysis. Both approaches differ in multiple elements of set-up (e.g., overground versus treadmill, Pug-in Gait versus Human Body Model-II), workflow (e.g., limited amount of steps versus many successive steps) and post-processing of data (e.g., different filter techniques). These individual elements have shown to affect gait. Since the approaches are used in parallel in clinical practice, insight into the compound effect of the multiple different elements on gait is essential. This study investigates whether the outcomes of two approaches for 3D gait analysis are interchangeable in typically developing children. Methods Spatiotemporal parameters, sagittal joint angles and moments, and ground reaction forces were measured in typically developing children aged 3-17 years using the overground (overground walking, conventional lab environment, Plug-In Gait) and treadmill (treadmill walking in virtual environment, Human Body Model-II) approach. Spatiotemporal and coefficient of variation parameters, and peak values in kinematics and kinetics of both approaches were compared using repeated measures tests. Kinematic and kinetic waveforms from both approaches were compared using statistical parametric mapping (SPM). Differences were quantified by mean differences and root mean square differences. Results Children walked slower, with lower stride and stance time and shorter and wider steps with the treadmill approach than with the overground approach. Mean differences ranged from 0.02 s for stride time to 3.3 cm for step width. The patterns of sagittal kinematic and kinetic waveforms were equivalent for both approaches, but significant differences were found in amplitude. Overall, the peak joint angles were larger during the treadmill approach, showing mean differences ranging from 0.84° (pelvic tilt) to 6.42° (peak knee flexion during swing). Mean difference in peak moments ranged from 0.02 Nm/kg (peak knee extension moment) to 0.32 Nm/kg (peak hip extension moment), showing overall decreased joint moments with the treadmill approach. Normalised ground reaction forces showed mean differences ranging from 0.001 to 0.024. Conclusion The overground and treadmill approach to 3D gait analysis yield different sagittal gait characteristics. The systematic differences can be due to important changes in the neuromechanics of gait and to methodological choices used in both approaches, such as the biomechanical model or the walkway versus treadmill. The overview of small differences presented in this study is essential to correctly interpret the results and needs to be taken into account when data is interchanged between approaches. Together with the research/clinical question and the context of the child, the insight gained can be used to determine the best approach.
Collapse
|
8
|
Effectiveness and cost-effectiveness of dynamic bracing versus standard care alone in patients suffering from osteoporotic vertebral compression fractures: protocol for a multicentre, two-armed, parallel-group randomised controlled trial with 12 months of follow-up. BMJ Open 2022; 12:e054315. [PMID: 35613823 PMCID: PMC9125700 DOI: 10.1136/bmjopen-2021-054315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Patients with osteoporosis may suffer from a fracture after minimal trauma. Osteoporotic vertebral compression fractures (OVCFs) are among the most common fractures, often leading to substantial pain. There is a need for evidence-based conservative treatment to aid in the management of OVCFs. The objective of this randomised controlled trial (RCT) is to evaluate the effectiveness and cost-effectiveness of dynamic bracing in addition to standard care for improving quality of life (QoL) in patients suffering from an OVCF. METHODS AND ANALYSIS Ninety-eight postmenopausal women from two academic and four community hospitals with a recent symptomatic thoracolumbar OVCF will be randomised into either the standard care or dynamic bracing group. In the dynamic bracing group, the Spinova Osteo orthosis will be used in addition to standard care. Standard care comprises pain control with analgesics, physical therapy and osteoporosis medication. The primary outcome parameter is QoL 1 year after inclusion, as measured by the Quality of Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-41). Secondary outcome parameters are pain, pain medication used, functional disability, sagittal spinal alignment, recurrence rate of OVCFs and physical activity in daily life. A trial-based economic evaluation consisting of both cost-effectiveness analysis and cost-utility analysis will be performed based on empirical data obtained in the RCT. A process evaluation will assess the feasibility of dynamic bracing. All outcomes will be assessed at baseline, 6 weeks, 3 months, 6 months, 9 months and 12 months. ETHICS AND DISSEMINATION Ethical approval has been granted by the Medical Ethics Committee, University Hospital Maastricht and Maastricht University (METC azM/UM) (NL74552.068.20/METC 20-055). Patients will be included only after verification of eligibility and obtaining written informed consent. Results will be disseminated via the Dutch National Osteoporosis Patient Society and via publications and conferences. TRIAL REGISTRATION NUMBER NL8746.
Collapse
|
9
|
Metal ion concentrations after metal-on-metal hip arthroplasty are not correlated with habitual physical activity levels. Hip Int 2019; 29:638-646. [PMID: 30479165 DOI: 10.1177/1120700018814225] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Metal-on-metal (MoM) hip arthroplasties have shown high clinical failure rates with many patients at risk for a revision and under surveillance for high metal ion concentrations. Implant wear releasing such ions is assumed to be a function of use, i.e. the patient's physical activity. This study aimed to assess whether habitual physical activity levels of MoM patients are correlated with metal ion concentrations and are higher in patients with high (at risk) than in patients with low (safe) metal ion concentrations. METHODS A cohort study was conducted of patients with any type of MoM hip prosthesis. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. RESULTS In total, 62 patients were included. Mean age at surgery was 60.8 ± 9.3 years and follow-up was 6.3 ± 1.4 years. Cobalt concentrations were highly elevated overall (112.4 ± 137.9 nmol/L) and significantly more in bilateral (184.8 ± 106.5 nmol/L) than in unilateral cases (87.8 ± 139.4 nmol/L). No correlations were found between physical activity parameters and metal ion concentrations. Subgroup analysis of patients with low versus high cobalt concentration showed no significant differences in habitual physical activity. DISCUSSION No correlation was found between physical activity levels and metal ion concentrations. Implant use by normal habitual activities of daily living seems not to influence metal ion concentrations.
Collapse
|
10
|
Gait in patients with symptomatic osteoporotic vertebral compression fractures over 6 months of recovery. Aging Clin Exp Res 2019; 32:239-246. [PMID: 31030421 PMCID: PMC7033073 DOI: 10.1007/s40520-019-01203-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Accepted: 04/09/2019] [Indexed: 11/05/2022]
Abstract
Background One factor related to disability in people with spinal deformity is decreased postural control and increased risk of falling. However, little is known about the effect of osteoporotic vertebral compression fractures (OVCFs) and their recovery on gait and stability. Walking characteristics of older adults with and without vertebral fractures have not yet been compared. Aims The purpose of the current study was to examine the spatiotemporal gait parameters and their variability in patients with an OVCF and healthy participants during treadmill walking at baseline and after 6 months of recovery. Methods Twelve female patients suffering a symptomatic OVCF were compared to 11 matched controls. Gait analysis was performed with a dual-belt instrumented treadmill with a 180° projection screen providing a virtual environment (computer-assisted rehabilitation environment). Results of patients with an OVCF and healthy participants were compared. Furthermore, spatiotemporal gait parameters were assessed over 6 months following the fracture. Results Patients suffering from an OVCF appeared to walk with significantly shorter, faster and wider strides compared to their healthy counterparts. Although stride time and length improved over time, the majority of the parameters analysed remained unchanged after 6 months of conservative treatment. Discussion Since patients do not fully recover to their previous level of mobility after 6 months of conservative treatment for OVCF, it appears of high clinical importance to add balance and gait training to the treatment algorithm of OVCFs. Conclusions Patients suffering from an OVCF walk with shorter, faster and wider strides compared to their healthy counterparts adopt a less stable body configuration in the anterior direction, potentially increasing their risk of forward falls if perturbed. Although stride time and stride length improve over time even reaching healthy levels again, patients significantly deviate from normal gait patterns (e.g. in stability and step width) after 6 months of conservative treatment. Electronic supplementary material The online version of this article (10.1007/s40520-019-01203-9) contains supplementary material, which is available to authorized users.
Collapse
|
11
|
Effect of a semirigid thoracolumbar orthosis on gait and sagittal alignment in patients with an osteoporotic vertebral compression fracture. Clin Interv Aging 2019; 14:671-680. [PMID: 31043773 PMCID: PMC6469477 DOI: 10.2147/cia.s199853] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Background An important goal in the treatment of osteoporotic vertebral compression fractures (OVCFs) is the prevention of new vertebral fractures and the subsequent progression to global sagittal malalignment. Current conservative treatment is multimodal and comprises analgesics, medication for osteoporosis, and physical therapy. However, little is known about the value of orthoses in the treatment of OVCFs. Aims The primary purpose of this study was to examine the direct effect of a semirigid thoracolumbar orthosis on gait in patients suffering from an OVCF. The secondary purpose was to evaluate changes in gait, radiographic sagittal alignment, pain, and quality of life over time. Methods Fifteen postmenopausal patients with an OVCF were treated with a semirigid thoracolumbar orthosis. At baseline, after 6 weeks, and after 6 months, gait analysis was performed with a dual belt-instrumented treadmill with a 180° projection screen providing a virtual environment (computer-assisted rehabilitation environment) combined with clinical and radiographic assessments. Results At baseline, bracing caused a significantly more upright posture during walking and patients walked faster, with larger strides, longer stride times, and lower cadence compared to walking without orthosis. After 6 weeks, radiographic and dynamic sagittal alignment had improved compared to baseline. The observed effect was gone after 6 months, when the orthosis was not worn anymore. Conclusion A semirigid thoracolumbar orthosis seems to have a positive effect on gait and stability in patients suffering from an OVCF, as was shown by a more upright posture, which may result in decreased compressive loading of the vertebrae. For studying the true effectiveness of dynamic bracing in the treatment of OVCFs, a prospective, randomized controlled trial will be needed.
Collapse
|
12
|
Clinical validation of a body-fixed 3D accelerometer and algorithm for activity monitoring in orthopaedic patients. J Orthop Translat 2017; 11:19-29. [PMID: 29662766 PMCID: PMC5866408 DOI: 10.1016/j.jot.2017.02.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 01/15/2017] [Accepted: 02/06/2017] [Indexed: 02/06/2023] Open
Abstract
Background/Objective Activity is increasingly being recognized as a highly relevant parameter in all areas of healthcare for diagnosis, treatment, or outcome assessment, especially in orthopaedics where the movement apparatus is directly affected. Therefore, the aim of this study was to develop, describe, and clinically validate a generic activity-monitoring algorithm, satisfying a combination of three criteria. The algorithm must be able to identify, count, and time a large set of relevant daily activities. It must be validated for orthopaedic patients as well as healthy individuals, and the validation must be in a setting that mimics free-living conditions. Methods Using various technical solutions, such as a dual-axis approach, dynamic inclinometry (hip flexion), and semiautomatic calibration (gait speed), the algorithms were designed to count and time the following postures, transfers, and activities of daily living: resting/sitting, standing, walking, ascending and descending stairs, sit-stand transitions, and cycling. In addition, the number of steps per walking bout was determined. Validation was performed with healthy individuals and patients who had undergone unilateral total joint arthroplasty, representing a wide spectrum of functional capacity. Video observation was used as the gold standard to count and time activities in a validation protocol approaching free-living conditions. Results In total 992 and 390 events (activities or postures) were recorded in the healthy group and patient group, respectively. The mean error varied between 0% and 2.8% for the healthy group and between 0% and 7.5% for the patient group. The error expressed in percentage of time varied between 2.0% and 3.0% for both groups. Conclusion Activity monitoring of orthopaedic patients by counting and timing a large set of relevant daily life events is feasible in a user- and patient-friendly way and at high clinical validity using a generic three-dimensional accelerometer and algorithms based on empirical and physical methods. The algorithms performed well for healthy individuals as well as patients recovering after total joint replacement in a challenging validation set-up. With such a simple and transparent method real-life activity parameters can be collected in orthopaedic practice for diagnostics, treatments, outcome assessment, or biofeedback.
Collapse
|
13
|
Validation of a novel activity monitor in impaired, slow-walking, crutch-supported patients. Ann Phys Rehabil Med 2016; 59:308-313. [PMID: 27659237 DOI: 10.1016/j.rehab.2016.05.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 05/25/2016] [Accepted: 05/29/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND A growing need in clinical practice of rehabilitation and orthopaedic medicine is for objective outcome tools to estimate physical activity. Current techniques show limited validity or are too demanding for routine clinical use. Accelerometer-based activity monitors (AMs) have shown promise for measuring physical activity in healthy people but lack validity in impaired patients. OBJECTIVES This study aimed to validate an accelerometer-based AM in impaired, slow-walking, crutch-supported patients after total joint arthroplasty (TJA). METHODS Shortly after TJA, patients who were safely mobilized with 2 crutches and 8 healthy participants completed a trial of different activities while wearing the AM on the lateral upper leg and being videotaped. Outcome variables (e.g., time walking, number of gait cycles, sit-stand-sit transfers) were compared to video recordings, and sensitivity, predictive value and mean percentage difference (MPD) values were calculated. RESULTS We included 40 patients (mean age: 65±9 years; mean BMI: 30±6kg/m2; male:female ratio: 18:22) and 8 healthy participants (mean age: 49±20 years; mean BMI: 23±0.7kg/m2; male:female ratio: 5:3). The AM showed excellent sensitivity (>95%) and predictive value (>95%) in identifying activities (e.g., walking, sitting, resting) and detecting the number of gait cycles and sit-stand-sit transfers (mean percentage difference: ±2%). Detection of number of steps ascending and descending stairs and cadence was more difficult but still showed good results (mean percentage difference: ±7%). CONCLUSIONS This is the first validation study to assess physical activity with an AM in impaired, slow-walking, crutch-supported patients. The AM was a valid tool for measuring physical activity in these patients. The tool may help in evaluating and optimizing rehabilitation programs for patients after TJA, those recovering from stroke or chronic impaired patients.
Collapse
|
14
|
Adjustments in 2011 KSS increase the clinical suitability. Acta Orthop Belg 2016; 82:43-51. [PMID: 26984653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The 2011 KSS is a valid clinical TKA questionnaire, but with a low completion rate (42%). Adjustments, focusing on optimizing scale features, are required to improve its clinical use. The low completion rates, non-optimal scale features, lacking rules or a combination of these factors where addressed, leading to the development of the adjusted 2011 KSS (2011 KSS-A). Four-hundred-ninety-nine primary TKA patients were addressed pre- and postoperative by mail. Clinimetric quality was evaluated. Seventy percent responded and 90% completed the scale. Internal consistency proved excellent with Cronbach's Alpha≥0.79 for all subscales. Strong correlations were found between the Functional Activity subscales and KOOS-PS (r=-0.63 to -0.87). All subscales improved significantly after intervention (r-range 14-33%, effect size 0.50-2.85). Postoperatively, ceiling effects were found in the subscales Symptoms (16%) and Walking & Standing (26%). Adjustments led to a shortened and simplified questionnaire while maintaining its clinimetric quality.
Collapse
|
15
|
Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system. Med Eng Phys 2015; 38:225-31. [PMID: 26711470 DOI: 10.1016/j.medengphy.2015.11.009] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Revised: 11/18/2015] [Accepted: 11/29/2015] [Indexed: 11/30/2022]
Abstract
An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (ADL): gait, sit-to-stand (STS) transfers and block step-up (BS) transfers. A single IMU was attached onto the lower back in seventeen healthy participants (8F/9 M, age 19-31 years; BMI < 25) and optical skin markers were attached onto anatomical pelvic landmarks for MOCAP measurements. Comparisons between IMU and MOCAP by Bland-Altman plots demonstrated that measurements were between 2SD of the absolute difference and Pearson's correlation coefficients were between 0.85 and 0.94. Frontal plane pelvic angle estimations achieved a RMSE in the range of [2.7°-4.5°] and sagittal plane measurements achieved a RMSE in the range of [2.7°-8.9°] which were both lowest in gait. Waveform peak detection times demonstrated ICCs between 0.96 and 1.00. These results are in accordance to other studies comparing IMU and MOCAP measurements with different applications and suggest that an IMU is a valid tool to measure dynamic pelvic angles during various activities of daily life which could be applied to monitor rehabilitation in a wide variety of musculoskeletal disorders.
Collapse
|
16
|
Accelerometer-based Physical Activity Monitoring in Patients with Knee Osteoarthritis: Objective and Ambulatory Assessment of Actual Physical Activity During Daily Life Circumstances. Open Biomed Eng J 2015; 9:157-63. [PMID: 26312077 PMCID: PMC4541405 DOI: 10.2174/1874120701509010157] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 11/21/2014] [Accepted: 12/19/2014] [Indexed: 12/27/2022] Open
Abstract
Background: It is important to assess physical activity objectively during daily life circumstances, to understand the association between physical activity and diseases and to determine the effectiveness of interventions. Accelerometer-based physical activity monitoring seems a promising method and could potentially capture all four FITT (i.e. Frequency, Intensity, Time, Type) components of physical activity considered by the World Health Organization (WHO). Aim: To assess the four FITT components of physical activity with an accelerometer during daily life circumstances and compare with self-reported levels of physical activity in patients with knee osteoarthritis (OA) and a healthy control group. Methods: Patients (n=30) with end-stage knee OA and age-matched healthy subjects (n=30) were measured. An ambulant tri-axial accelerometer was placed onto the lateral side of the upper leg. Physical activity was measured during four consecutive days. Using algorithm-based peak detection methods in Matlab, parameters covering the four FITT components were assessed. Self-reported physical activity was assessed using the Short questionnaire to assess health enhancing physical activity (SQUASH). Results: Knee OA patients demonstrated fewer walking bouts (154 ±79 versus 215 ±65 resp.; p=0.002), step counts (4402 ±2960 steps/day versus 6943 ±2581 steps/day; p=0.001) and sit-to-stand (STS) transfers (37 ±14 versus 44 ±12; p=0.031) compared to controls. Knee OA patients demonstrated more time sitting (65 ±15% versus 57 ±10% resp.; p=0.029), less time walking (8 ±4% versus 11 ±4% resp.; p=0.014) and lower walking cadence (87 ±11steps/min versus 99 ± 8steps/min resp.; p<0.001). Accelerometer-based parameters of physical activity were moderately-strong (Pearsons’s r= 0.28-0.49) correlated to self-reported SQUASH scores. Conclusion: A single ambulant accelerometer-based physical activity monitor feasibly captures the four FITT components of physical activity and provides more insight into the actual physical activity behavior and limitations of knee OA patients in their daily life.
Collapse
|
17
|
Physical functioning of low back pain patients: perceived physical functioning and functional capacity, but not physical activity is affected. Disabil Rehabil 2015; 37:2257-63. [DOI: 10.3109/09638288.2015.1019010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
18
|
Clinimetric quality of the new 2011 Knee Society score: high validity, low completion rate. Knee 2014; 21:647-54. [PMID: 24613585 DOI: 10.1016/j.knee.2014.02.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 01/23/2014] [Accepted: 02/05/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND The demands of the younger and more active current total knee arthroplasty (TKA) patients are not in line with the current outcome assessments. Therefore, new questionnaires are developed or adjusted, as with the popular 1989 Knee Society Score (KSS). This study is the first to investigate the clinimetric parameters of the patient-reported outcome measurement (PROM) part of the 2011 KSS. METHODS Four-hundred-fifteen primary Dutch TKA patients were scored using the PROM part of the 2011 KSS. The scale is subdivided into an Objective (not evaluated), Satisfaction, Expectation and Function subscales. Clinimetric quality was evaluated by response and completion rate, test-retest reliability (n=29, intraclass correlation coefficient), internal consistency (n=172, Cronbach's alpha), construct validity (Pearson's correlations with 1989 KSS (n=75) and KOOS-PS (n=139)) and responsiveness (n=20, paired-samples t-test, effect sizes and floor and ceiling effects). RESULTS A response rate of 96% and completion rate of 43% were found. Reliability and internal consistency proved excellent with ICCs≥0.79 and Cronbach's alpha≥0.76 for all subscales. Strong correlations were found between the Function subscales of the 2011 KSS and KOOS-PS (r=-0.60 to -0.83). All subscales improved significantly after intervention, with exception of Walking & Standing and Discretionary Activities. 23% reached the maximum score postoperatively in Walking & Standing, indicating a ceiling effect. CONCLUSIONS The 2011 KSS is a reliable, internal consistent, construct valid and responsive questionnaire to assess the outcome of the Dutch TKA patients. Optimizations (e.g. shortening the scale, simplified design) are recommended to increase the disappointing completion rate. CLINICAL RELEVANCE The 2011 KSS is a reliable, internal consistent, construct valid and responsive questionnaire to assess the outcome of the Dutch TKA patients.
Collapse
|
19
|
Objective outcome evaluation using inertial sensors in subacromial impingement syndrome: a five-year follow-up study. Physiol Meas 2014; 35:677-86. [PMID: 24622109 DOI: 10.1088/0967-3334/35/4/677] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Shoulder-related dysfunction is the second most common musculoskeletal disorder and is an increasing burden on health-care systems. Commonly used clinical questionnaires suffer from subjectivity, pain dominance and a ceiling effect. Objective functional measurement has been identified as a relevant issue in clinical rehabilitation. Inertia based motion analysis (IMA) is a new generation of objective outcome assessment tool; it can produce objective movement parameters while being fast, cheap and easy to operate. In this prospective study, an inertial sensor comprising a three-dimensional accelerometer and gyroscope is attached at the humerus to measure shoulder movements during two motion tasks in patients with subacromial impingement syndrome at baseline and at five-year after treatment. One hundred healthy subjects served as healthy reference database and 15 patients were measured pre- and post-treatment. IMA was better able to detect improvement in shoulder movements compared to the clinical questionnaires (Disability of Arm, Shoulder and Hand (DASH) and Simple Shoulder Test (SST); p < 0.05) and was hardly correlated with the clinical questionnaires (Pearson R = 0.39). It may therefore add an objective functional dimension to outcome assessment. The fast assessment (t < 5 min) of a simple motion test makes it suitable for routine clinical follow-up.
Collapse
|
20
|
The influence of age, muscle strength and speed of information processing on recovery responses to external perturbations in gait. Gait Posture 2013; 39:513-7. [PMID: 24119777 DOI: 10.1016/j.gaitpost.2013.08.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Revised: 08/14/2013] [Accepted: 08/30/2013] [Indexed: 02/02/2023]
Abstract
Dynamic imbalance caused by external perturbations to gait can successfully be counteracted by adequate recovery responses. The current study investigated how the recovery response is moderated by age, walking speed, muscle strength and speed of information processing. The gait pattern of 50 young and 45 elderly subjects was repeatedly perturbed at 20% and 80% of the first half of the swing phase using the Timed Rapid impact Perturbation (TRiP) set-up. Recovery responses were identified using 2D cameras. Muscular factors (dynamometer) and speed of information processing parameters (computer-based reaction time task) were determined. The stronger, faster reacting and faster walking young subjects recovered more often by an elevating strategy than elderly subjects. Twenty three per cent of the differences in recovery responses were explained by a combination of walking speed (B=-13.85), reaction time (B=-0.82), maximum extension strength (B=0.01) and rate of extension moment development (B=0.19). The recovery response that subjects employed when gait was perturbed by the TRiP set-up was modified by several factors; the individual contribution of walking speed, muscle strength and speed of information processing was small. Insight into remaining modifying factors is needed to assist and optimise fall prevention programmes.
Collapse
|
21
|
Accelerometry-based gait analysis, an additional objective approach to screen subjects at risk for falling. Gait Posture 2012; 36:296-300. [PMID: 22512847 DOI: 10.1016/j.gaitpost.2012.03.015] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2011] [Revised: 03/10/2012] [Accepted: 03/19/2012] [Indexed: 02/02/2023]
Abstract
This study investigated whether the Tinetti scale, as a subjective measure for fall risk, is associated with objectively measured gait characteristics. It is studied whether gait parameters are different for groups that are stratified for fall risk using the Tinetti scale. Moreover, the discriminative power of gait parameters to classify elderly according to the Tinetti scale is investigated. Gait of 50 elderly with a Tinneti>24 and 50 elderly with a Tinetti≤24 was analyzed using acceleration-based gait analysis. Validated algorithms were used to derive spatio-temporal gait parameters, harmonic ratio, inter-stride amplitude variability and root mean square (RMS) from the accelerometer data. Clear differences in gait were found between the groups. All gait parameters correlated with the Tinetti scale (r-range: 0.20-0.73). Only walking speed, step length and RMS showed moderate to strong correlations and high discriminative power to classify elderly according to the Tinetti scale. It is concluded that subtle gait changes that have previously been related to fall risk are not captured by the subjective assessment. It is therefore worthwhile to include objective gait assessment in fall risk screening.
Collapse
|
22
|
The importance to including objective functional outcomes in the clinical follow up of total knee arthroplasty patients. Knee 2011; 18:306-11. [PMID: 20817472 DOI: 10.1016/j.knee.2010.07.008] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Revised: 07/20/2010] [Accepted: 07/20/2010] [Indexed: 02/02/2023]
Abstract
In clinical practice, it is increasingly important to assess patients' daily functionality routinely and objectively. Acceleration-based gait analysis (AGA) has shown to be reliable and technically suitable for routine clinical use outside the laboratory. This study investigated the suitability of AGA for measuring function in orthopaedic patients with symptomatic gonarthrosis listed for total knee arthroplasty (TKA) by investigating (a) the ability of AGA to distinguish patients from healthy subjects, (b) the sensitivity to gait changes of AGA in assessing recovery following total knee arthroplasty in a subpopulation, and (c) correlations between AGA parameters and clinical scales. Gait was assessed using AGA in 24 patients with symptomatic gonarthrosis listed for TKA, and in 24 healthy subjects. AGA parameters (e.g. speed, asymmetry) and clinical scales (e.g. KSS) were used to monitor progress in 12 patients 3 months after TKA. The Mann-Whitney-U test, Receiver Operating Characteristic (ROC) curves, repeated measurement ANOVA and Pearson correlations were performed. AGA differentiated pathological from healthy gait. The area under the ROC curve, sensitivity and specificity values were high for speed, step frequency and step length. Different recovery profiles were found, with clinical scales showing faster recovery rates. None or only weak correlations were found between AGA and clinical scores. AGA was found to be of clinical relevance in identifying and monitoring patients with symptomatic gonarthrosis in orthopaedic practice, providing objective and additional information about function beyond clinical scales. This, together with the fact that AGA can be applied routinely, suggests the suitability of AGA for use in rehabilitation programs.
Collapse
|
23
|
Towards unobtrusive in vivo monitoring of patients prone to falling. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:5018-21. [PMID: 21096022 DOI: 10.1109/iembs.2010.5626232] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Falling is a serious health problem for many elderly. To investigate whether the higher fall incidence in elderly is due to a higher probability of experiencing near falls in daily life, it is necessary to evaluate the stumble incidence of elderly in daily life. Accelerometers are already frequently used for in vivo activity monitoring. The current study investigates whether an ambulant and unobtrusive accelerometer can identify stumbles from treadmill walking using a wavelet based detection approach. Seventy nine healthy subjects walked on a treadmill with a triaxial accelerometer attached at the level of the sacrum. Stumbles were induced using a specially designed braking system (The TRiP). The TRiP evoked 30 stumbles at different phases of the swing phase. A wavelet-based detection algorithm is used to isolate the stumbles from treadmill walking, with a specificity of 99.9% and a sensitivity of 98.4%.
Collapse
|
24
|
Early functional outcome after subvastus or parapatellar approach in knee arthroplasty is comparable. Knee Surg Sports Traumatol Arthrosc 2011; 19:943-51. [PMID: 20953864 PMCID: PMC3096777 DOI: 10.1007/s00167-010-1292-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Accepted: 09/28/2010] [Indexed: 01/09/2023]
Abstract
PURPOSE In total knee arthroplasty, tissue-sparing techniques are considered more important, as functional gain could become more advantageous when early mobilization is commenced. The parapatellar approach is most often used, whereas the subvastus approach is a suitable alternative. Presently, it is unknown, according to true objective measurements, which of the two is most advantageous. METHODS In this prospective randomized double-blind, short-term trial measurements (KSS, WOMAC, PDI, VAS, ability to perform) were obtained at day 1, day 3, 1 week, 6 weeks, and 3 months. RESULTS The subvastus group (n=20) showed only significantly less extension lag direct postoperative (P=0.04) compared with the parapatellar group (n=20). Other scores were not significantly different. The Dynaport®knee test, an objective performance-based tool, could not demonstrate significant differences. A blunt anatomical dissection was carried out in both observational and histological to support findings. A dense innervation of the distal vastus medialis was found. This is at risk employing the subvastus approach. Both approaches harm the suprapatellar bursa. The vastus medialis sheath must be detached distally to open the knee joint. No true separate vastus medialis obliquus could be identified. CONCLUSION Comparable to literature, only mild advantage employing the subvastus approach was found, but only early postoperative and not objectively. As this approach is also not suitable in every case, we will continue to use the parapatellar approach.
Collapse
|
25
|
Acceleration-based gait test for healthy subjects: reliability and reference data. Gait Posture 2009; 30:192-6. [PMID: 19477649 DOI: 10.1016/j.gaitpost.2009.04.008] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Revised: 04/15/2009] [Accepted: 04/25/2009] [Indexed: 02/02/2023]
Abstract
Accelerometers enable us to analyse gait outside conventional gait laboratories. Before these devices can be used in large scale studies and in clinical settings a thorough evaluation of their performance in different populations is required. The aim of this study was to present an acceleration-based reference database for healthy gait. The repeatability and inter-observer reliability of acceleration-based gait analysis was investigated. The sensitivity was tested on different age groups and the effect of gender was studied. A comprehensive set of gait parameters (i.e. cadence, speed, asymmetry and irregularity) were studied in 60 women and 60 men. Basic gait parameters showed high repeatability (VC(cadence) 1.51%, ICC(cadence) 0.996) and inter-observer reliability (ICC(cadence) 0.916), while asymmetry and irregularity showed lower repeatability (VC(asym) 47.88%, ICC(asym) 0.787) and inter-observer reliability (ICC(asym) 0.449). The effects of age and gender on gait parameters were found to be consistent with those reported in studies using other methodologies. These findings and the advantages of the device support the application of AGA for routine clinical use and in daily life.
Collapse
|
26
|
Patella retention versus replacement in total knee arthroplasty; functional and clinimetric aspects. Arch Orthop Trauma Surg 2009; 129:259-65. [PMID: 18488236 DOI: 10.1007/s00402-008-0640-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2007] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Whether to resurface the patella or not in total knee arthroplasty still remains undecided. Classical scores and questionnaires might not be responsive or demanding enough. This study used two accelerometer based systems to study the hypothesis whether performance based tests are able to detect a difference in patients with or without a resurfaced patella. METHOD In this retrospective study 53 patients were included and divided into a resurfaced group (n = 31) and a non-resurfaced group (n = 22). Both groups were matched on age and longevity of follow up. Patients were clinically assessed using the Knee Society Score (KSS) at various time points. At final follow up patients were also assessed once using the Dynaport Knee Test and the Minimod Gait Test. RESULTS The Dynaport Knee Test showed a significant functional advantage for patients with a resurfaced patella [44 vs. 39.7 (P = 0.042)], whereas KSS and The Minimod were not significant (P values ranging from 0.07 to 0.75). Similar to other reports in literature, using the KSS, it was not possible to identify significant difference between patella resurfacing or retaining in total knee arthroplasty, however using a performance based test it was possible to determine significant difference. The found advantage of patella resurfacing may be less due to pain relief but due to a functional benefit during demanding motion tasks. This finding indicates that current measurement tools may not be accurate or specific enough to detect this difference. Therefore, we recommend complementing the classic evaluation tools with an objective functional test, when conducting a randomized trial to answer the indecision whether to resurface the patella or not.
Collapse
|
27
|
An inertial measurement system that differentiates between healthy and pathological gait. J Biomech 2007. [DOI: 10.1016/s0021-9290(07)70345-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Sci-PM Sat - 03: Conformal dose verification using cone beam optical computed tomography and polymer gel dosimeters: A feasibility study. Med Phys 2005. [DOI: 10.1118/1.2031062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
29
|
Conduction velocity of the distal segment of the saphenous nerve in normal adult subjects. ELECTROMYOGRAPHY AND CLINICAL NEUROPHYSIOLOGY 1981; 21:3-10. [PMID: 7215282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|