1
|
Multipoint monitor of beer fermentation. Food Chem 2024; 452:139613. [PMID: 38744125 DOI: 10.1016/j.foodchem.2024.139613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/25/2024] [Accepted: 05/07/2024] [Indexed: 05/16/2024]
Abstract
This short communication is devoted to a fully-mechanized flow analysis system for the control of beer fermentation process. The developed system is based on microsolenoid flow controlling devices (valves and pumps) and a flow-through optoelectronic detector. All these components are powered and controlled by a Adruino-compatible microprocessor platform that creates an integrated, compact, and robust analytical tool. Multiplication of sample aspiration ports of the analytical system allows for simultaneous monitoring of several independently performed fermentation processes, as well as a single process at the different places of fermentation tank. To demonstrate its practical utility, the developed system has been applied for online and real-time monitoring of yeast propagation and distribution in beer worts in the course of various fermentation processes. Potentially, this flow analysis system can be easily expanded to the form of multianalyte monitor equipped with optoelectronic sensors and biosensors for the determination of other parameters and analytes.
Collapse
|
2
|
Turbidimetric flow analysis system for the investigation of microbial growth. Talanta 2024; 268:125303. [PMID: 37852015 DOI: 10.1016/j.talanta.2023.125303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/03/2023] [Accepted: 10/07/2023] [Indexed: 10/20/2023]
Abstract
The monitoring of life of microbial populations is of the uttermost importance in environmental and food analysis, agriculture, as well as in medicine. The duration of bacteria adaptation to new environmental conditions, its lifetime and the divisions' pace are the key information in many studies. It was found that the fully-mechanized flow analysis system based on solenoid valves and pumps, paired with a dedicated flow-through optoelectronic detector can be successfully applied for monitoring of bacteria growth. The applicability of the designed multicommutated flow analysis (MCFA) system was proved by analysis of solutions containing bacteria cells proceeded by tests of McFarland (McF) standards. The developed setup allowed modelling and simulation of microbial growth, as well as monitoring of the bacteria growth in real-time manner to be carried out. The monitor is useful for the quantitative estimation of the basic parameters of bacteria population like its size, the rate of bacteria multiplication, as well as the times of lag, log and stationary phases of microbial growth.
Collapse
|
3
|
Photometric flow system for the determination of serum lactate dehydrogenase activity. Talanta 2023; 265:124817. [PMID: 37418958 DOI: 10.1016/j.talanta.2023.124817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 06/07/2023] [Accepted: 06/12/2023] [Indexed: 07/09/2023]
Abstract
The routine method for LDH (Lactate dehydrogenase) activity determination is to monitor the increase of NADH concentration at 340 nm. There are some inconvenience in taking measurements in the near-UV region, especially in the case of serum samples analysis. In this work, two modifications of the routine LDH activity assay based on the use of reducing properties of NADH have been compared. Both methods involved the reduction of compounds that can be easily determined by well-known methods, ferric ion (with ferrozine) and nitrotetrazolium blue (NBT). A fully-mechanized Multicommutated Flow Analysis-Paired Emitter Detector Diode (MCFA-PEDD) system based on solenoid devices was developed and applied for both methods. The linear ranges obtained for Fe-ferrozine and NBT methods are 6.0-200.0 U L-1 and 10.0-250.0 U L-1 with estimated detection limits at 0.2 U L-1 and 4.5 U L-1, respectively. The low LOQ values enabled 10-fold sample dilutions, which is advantageous for samples with limited available volume. The Fe-ferrozine method is more selective for LDH activity in the presence of glucose, ascorbic acid, albumin, bilirubin, copper and calcium ions than NBT method. To confirm the analytical usefulness of the proposed flow system, the analysis of real human serum samples was carried out. The statistic tests showed satisfactory correlation between the results obtained for both developed methods and those received using the reference method.
Collapse
|
4
|
Multicommutation flow analysis system for non-enzymatic lactate determination based on light-driven photometric assay. Anal Chim Acta 2022; 1210:339878. [DOI: 10.1016/j.aca.2022.339878] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/28/2022] [Accepted: 04/23/2022] [Indexed: 11/26/2022]
|
5
|
Multicommutated Flow Analysis System for Determination of Horseradish Peroxidase and Its Inhibitors. Molecules 2021; 26:molecules26185630. [PMID: 34577101 PMCID: PMC8465280 DOI: 10.3390/molecules26185630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 09/08/2021] [Accepted: 09/13/2021] [Indexed: 11/16/2022] Open
Abstract
A fully mechanized multicommutated flow analysis (MCFA) system dedicated to determining horseradish peroxidase (HRP) activity was developed. Detection was conducted using a flow-through optoelectronic detector-constructed of paired LEDs operating according to the paired emitter-detector diode (PEDD) principle. The PEDD-MCFA system is dedicated to monitoring the enzyme-catalyzed oxidation of p-phenylenediamine (pPD) by a hydrogen peroxide. Under optimized conditions, the presented bioanalytical system was characterized by a linear response range (33.47-200 U/L) with a detection limit at 10.54 U/L HRP activity and 1.66 mV·L/U sensitivity, relatively high throughput (12 signals recordings per hour), and acceptable precision (RSD below 6%). Additionally, the utility of the developed PEDD-MCFA system for the determination of HRP inhibitors allowing the detection of selected thiols at micromolar levels, is demonstrated. The practical utility of the flow system was illustrated by the analysis of some dietary supplements containing L-cysteine, N-acetylcysteine, and L-glutathione.
Collapse
|
6
|
Bioanalytical insight into the life of microbial populations: A chemical monitoring of ureolytic bacteria growth. Enzyme Microb Technol 2021; 153:109899. [PMID: 34670184 DOI: 10.1016/j.enzmictec.2021.109899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/23/2021] [Accepted: 08/27/2021] [Indexed: 11/03/2022]
Abstract
In this publication an alternative approach to investigations of bacterial growth is proposed. Contrary to the conventional physical methods it is based on enzyme activity detection. The procedure for real-time and on-line monitoring of microbial ureolytic activity (applied as a model experimental biosystem) in the flow analysis format is presented. The developed fully-mechanized bioanalytical flow system is composed of solenoid micropumps and microvalves actuated by Arduino microcontroller. The photometric detection based on Nessler reaction is performed using dedicated flow-through optoelectronic detector made of paired light emitting diodes. The developed bioanalytical system allows discrete assaying of microbial urease in the wide range of activity up to 5.4 U mL-1 with detection limit below 0.44 U mL-1, a high sensitivity in the linear range of response (up to 200 mV U-1 mL and relatively high throughput (9 detection per hour). The proposed differential procedure of measurements (i.e. a difference between peaks register for sample with and without external addition of urea is treated as an analytical signal) allows elimination of interfering effects from substrate and products of biocatalysed reaction as well as other components of medium used for microbial growth. The developed bioanalytical system was successfully applied for the control of growth of urease-positive bacteria strains (Proteus vulgaris, Klebsiella pneumoniae and Paracoccus yeei) including examination of effects from various microbial cultivation conditions like temperature, composition of culture medium and amount of substrate required for induction of bacterial enzymatic activity. The developed bioanalytical flow system can be applied for metabolic activity-based estimation of parameters of lag and log phases of microbial growth as well as for detection of decline phase.
Collapse
|
7
|
The comparison between light-scattering detectors based on LED and photodiode for immunoprecipitation assays of transferrin and ferritin. Anal Chim Acta 2021; 1175:338753. [PMID: 34330448 DOI: 10.1016/j.aca.2021.338753] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 05/12/2021] [Accepted: 06/10/2021] [Indexed: 12/15/2022]
Abstract
Undoubtedly, light-emitting diodes (LEDs) and photodiodes (PDs) are indispensable optoelectronic devices in modern analytical chemistry. LEDs can serve as either light emitters or detectors, thus being an alternative to the most popular detection systems consisted of PD. In this contribution, a comparison between LED-LED and LED-PD detectors, operating in turbidimetric and nephelometric modes, has been carried out for immunoprecipitation detection of transferrin and ferritin. The greatest emphasis was placed on the study of detectors responses under different measurement conditions including current powering an emitter, amplification gain in the case of PD as detector or the construction of detection cells designed for the Multicommutated Flow Analysis (MCFA). The assumption was to obtain the fully-mechanized system with simple but efficient detection system to enable the determination of iron-binding proteins occurring at different concentration ranges in human body. As a result, the optimized arrangements of LED-LED and LED-PD setups were characterized by similar analytical characteristics, enabling the determination of transferrin with the detection limit (LOD) of 0.2 mg/L and RSDs of 2.8-4.8% for LED-LED, and LOD of 0.1 mg/L and RSDs of 0.9-3.6% for LED-PD. In the case of ferritin detection, only the response of the LED-PD detector was statistically distinguishable in the range of 130-198 μg/L of protein with recorded analytical signal change of 20 mV value. The addition of polymer for signal enhancement provided the increase of response range to 107-253 μg/L, enabling the developed system for detection of pathological serum ferritin levels.
Collapse
|
8
|
LED&Paper-based analytical device for phosphatemia/calcemia diagnostics☆. J Pharm Biomed Anal 2020; 186:113321. [PMID: 32413826 DOI: 10.1016/j.jpba.2020.113321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 01/30/2023]
Abstract
In this communication a prototype of paper-based analytical device designed for simultaneous determination of orthophosphate and calcium ions, which levels are significant for hyperphosphatemia diagnostics, is presented. The laboratory-on-paper structure for two analytes detection was wax-printed on the surface of filter paper. These two-analyte disposable paper strips are combined with two paired LED-based fluorescence detectors and simple voltmeter used as recorder of analytical signal, what makes the developed device miniature, extremely low-cost, portable and user-friendly. Thus the developed device allows usage outside of specialized clinical laboratory. Moreover, each paper strip is disposable and its utilization is easy and fast and, additionally, burnt strip tests ensure waste non-infectious. The presented LED&Paper-based analytical device provides low detection limits: 1.4 μmol L-1 and 7.4 μmol L-1 for orthophosphate and calcium ions, respectively. The practical utility of the developed device for calcemia/phosphatemia diagnostics is demonstrated using control serum standards and real human serum.
Collapse
|
9
|
Towards mechanized biparametric ceruloplasmin assay. Talanta 2020; 214:120881. [PMID: 32278433 DOI: 10.1016/j.talanta.2020.120881] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 02/24/2020] [Accepted: 02/26/2020] [Indexed: 11/29/2022]
Abstract
Two analytical strategies for determination of both biocatalytic activity and concentration of ceruloplasmin conditions have been proposed. For this purpose, two constructions of fully-mechanized Multicommutated Flow Analysis (MCFA) systems were designed. The versatility of solenoid pumps and valves arrangement enabled to construct both manifolds using similar flow units, taking into account the different requirements for each method. In the case of ceruloplasmin catalytic activity assay, the kinetic measurements with the use of p-phenylenediamine and hydrogen peroxide were performed. The optimization process was focused on the selection of substrate and oxidizer concentration, incubation time as well as solving the issue of substrate autoxidation. It led to the development of the flow bioanalytical system characterized by following analytical parameters: LOD - 0.07 U mL- 1, LOQ - 0.38 U mL-1, RSD ≤6% with 8 μL consumption of human serum. In turn, for examination of ceruloplasmin concentration, the light-scattering detector was used in MCFA system adapted for immunoprecipitation measurements. In this case, the use of potentiator (polyethylene glycol) turned out to be necessary to obtain satisfactory analytical signals. Such a method allowed to obtain 35 measurements per hour with LOD and LOQ of 0.9 mg L-1 and 3.2 mg L-1, respectively. The usefulness of both MCFA systems was successfully examined by performing analyses of real human serum samples.
Collapse
|
10
|
A remote-controlled immunochemical system for nephelometric detection of human serum transferrin. Biosens Bioelectron 2019; 127:31-37. [DOI: 10.1016/j.bios.2018.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
11
|
A mechanized urease activity assay. Enzyme Microb Technol 2019; 123:1-7. [PMID: 30686345 DOI: 10.1016/j.enzmictec.2019.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 12/30/2018] [Accepted: 01/02/2019] [Indexed: 11/19/2022]
Abstract
Two fully mechanized flow analysis systems for urease activity assays have been developed, characterized and compared. Both of them are based on almost the same compact system of solenoid micropumps and microvalves controlled and actuated by highly effective, low-power and economic Arduino microcontroller. For photometric detection of ammonia formed in the course of enzymatic hydrolysis of urea, the Berthelot method and the Nessler reaction have been examined. For both these detection schemes very simple dedicated optoelectronic flow-through detectors made of paired light emitting diodes have been developed. In both systems single enzyme assay lasting a few minutes allows determination of urease in activity range 0.02-5.3 U mL-1 with detection limit 0.02 U mL-1 and in 1.3-5.3 U mL-1 range with 0.75 U mL-1 detection limit for Nessler reaction and Berthelot method based systems, respectively. When compared with mechanized Berthelot method, the bioanalytical system based on Nessler reaction offers higher sensitivity, lower detection/determination limits, better selectivity and lower cost of the assay. It has been demonstrated that the developed bioanalytical flow systems could be useful for urease determination in complex biological matrix like plant extracts and media for microbial cultures as well as for inhibitive determination of heavy metals at sub-ppm levels.
Collapse
|
12
|
Optoelectronic detectors for flow analysis systems manufactured by means of rapid prototyping technology. Talanta 2019; 198:169-178. [PMID: 30876546 DOI: 10.1016/j.talanta.2019.01.092] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 01/22/2019] [Accepted: 01/24/2019] [Indexed: 10/27/2022]
Abstract
Universal, customizable design of 3D printed photometric, and fluorometric flow-through detectors have been presented. The developed designs were fabricated with the use of the most affordable 3D printing technique, namely Fused Filament Fabrication, and require neither hardware nor tools to assemble. Numerous variants of detector geometries have also been presented. The designed parameters varied both in aperture (i.e., the internal diameter of the flow channel in an optical path) and in thickness of an absorbing layer. As expected, the geometry of the channels resulted in changes in the internal volumes. Two concepts of fluorometric detectors have also been described. The utility of all developed flow-through detectors was proven with the use of mechanized calibrations of both photometric and fluorometric experiments. Analytical parameters were characterized with the use of two model dyes: bromothymol blue and fluorescein for photometric and fluorometric experiments, respectively. The repeatability of the 3D printed vessels was found at 3.5-8.0% of the mean relative standard deviation (RSD), depending on the construction of the vessel, which is comparable to rather expensive commercially available flow cells. The compatibility of used 3D printing materials was also examined. For both variants of detection light emitting diodes were applied as light emitters. As the light detectors, both CCD spectrophotometers and light-emitting diodes were used.
Collapse
|
13
|
Microfluidic Analysis with Front-Face Fluorometric Detection for the Determination of Total Inorganic Iodine in Drinking Water. ANAL SCI 2018; 34:161-167. [PMID: 29434101 DOI: 10.2116/analsci.34.161] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A microfluidic method with front-face fluorometric detection was developed for the determination of total inorganic iodine in drinking water. A polydimethylsiloxane (PDMS) microfluidic device was employed in conjunction with the Sandell-Kolthoff reaction, in which iodide catalyzed the redox reaction between Ce(IV) and As(III). Direct alignment of an optical fiber attached to a spectrofluorometer was used as a convenient detector for remote front-face fluorometric detection. Trace inorganic iodine (IO3- and I-) present naturally in drinking water was measured by on-line conversion of iodate to iodide for determination of total inorganic iodine. On-line conversion efficiency of iodate to iodide using the microfluidic device was investigated. Excellent conversion efficiency of 93 - 103% (%RSD = 1.6 - 11%) was obtained. Inorganic iodine concentrations in drinking water samples were measured, and the results obtained were in good agreement with those obtained by an ICP-MS method. Spiked sample recoveries were in the range of 86%(±5) - 128%(±8) (n = 12). Interference of various anions and cations were investigated with tolerance limit concentrations ranging from 10-6 to 2.5 M depending on the type of ions. The developed method is simple and convenient, and it is a green method for iodine analysis, as it greatly reduces the amount of toxic reagent consumed with reagent volumes in the microfluidic scale.
Collapse
|
14
|
Photometric and fluorometric alkaline phosphatase assays using the simplest enzyme substrates. Talanta 2018; 190:193-198. [PMID: 30172498 DOI: 10.1016/j.talanta.2018.07.052] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 07/12/2018] [Accepted: 07/16/2018] [Indexed: 11/29/2022]
Abstract
In this contribution a highly cost-effective flow analysis system for determination of alkaline phosphatase (ALP) activity is presented. This fully-mechanized bioanalytical system is based on economic solenoid micropumps and microvalves (powered and actuated by Arduino microcontroller) and extremely cheap dedicated optoelectronic flow-through detectors allowing absorbance and fluorescence measurements. The detection schemes for ALP assaying realized in this system are based on orthophosphate determination. For the detection of these ions formed in the course of enzymatic conversion a molybdate method requiring only common and inexpensive chemicals is utilized. Thus, for the enzymatic assays the simplest not-chromogenic/not-fluorogenic ALP substrates can be applied. Such approach results in the use of low-cost reagents for ALP assays, whereas the mechanization of assay causes low consumption of reagents as well as samples. In the course of reported investigations six ALP substrates were examined and the most promising results have been obtained for the inorganic compound - monofluorophosphate (MFP). The obtained linear ranges of absorbance and fluorescence measurements are 100-600 U L-1 and 30-30/30-100 U L-1, with sensitivities of 0.7 mV L-1 U-1 and 2.3/1.0 mV L-1 U-1, respectively. The calculated limits of detection are 5.1 U L-1 (photometry) and 0.9 U L-1 (fluorometry). The throughputs of the developed system are 13 and 12 samples/h for photometric and fluorometric detections, respectively. To demonstrate the practical utility of the developed bioanalytical system the ALP assays in complex matrix samples have been carried out. The results of ALP activity determination in serum samples are well-correlated with those obtained using reference method recommended for routine clinical analysis.
Collapse
|
15
|
|
16
|
Photometric flow analysis system for biomedical investigations of iron/transferrin speciation in human serum. Anal Chim Acta 2017; 995:43-51. [PMID: 29126480 DOI: 10.1016/j.aca.2017.10.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Revised: 10/11/2017] [Accepted: 10/17/2017] [Indexed: 01/28/2023]
Abstract
The Multicommutated Flow Analysis (MCFA) system for the estimation of clinical iron parameters: Serum Iron (SI), Unsaturated Iron Binding Capacity (UIBC) and Total Iron Binding Capacity (TIBC) has been proposed. The developed MCFA system based on simple photometric detection of iron with chromogenic agent (ferrozine) enables a speciation of transferrin (determination of free and Fe-bound protein) in human serum. The construction of manifold was adapted to the requirements of measurements under changing conditions. In the course of studies, a different effect of proteins on SI and UIBC determination has been proven. That was in turn the reason to perform two kinds of calibration methods. For measurements in acidic medium for SI/holotransferrin determination, the calibration curve method was applied, characterized by limit of determination and limit of quantitation on the level of 3.4 μmol L-1 and 9.1 μmol L-1, respectively. The determination method for UIBC parameter (related to apotransferrin level) in physiological medium of pH 7.4 forced the use of standard addition method due to the strong influence of proteins on obtaining analytical signals. These two different methodologies, performed in the presented system, enabled the estimation of all three clinical iron/transferrin parameters in human serum samples. TIBC corresponding to total transferrin level was calculated as a sum of SI and UIBC.
Collapse
|
17
|
Optoelectronic iron detectors for pharmaceutical flow analysis. J Pharm Biomed Anal 2017; 145:504-508. [PMID: 28746909 DOI: 10.1016/j.jpba.2017.06.057] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 06/22/2017] [Accepted: 06/25/2017] [Indexed: 11/29/2022]
Abstract
Compact flow-through optoelectronic detectors fabricated by pairing of light emitting diodes have been applied for development of economic flow analysis systems dedicated for iron ions determination. Three analytical methods with different chromogens selectively recognizing iron ions have been compared. Ferrozine and ferene S based methods offer higher sensitivity and slightly lower detection limits than method with 1,10-phenantroline, but narrower ranges of linear response. Each system allows detection of iron in micromolar range of concentration with comparable sample throughput (20 injections per hour). The developed flow analysis systems have been successfully applied for determination of iron in diet supplements. The utility of developed analytical systems for iron release studies from drug formulations has also been demonstrated.
Collapse
|
18
|
A multicommutated tester of bioreactors for flow analysis. Talanta 2016; 160:233-240. [DOI: 10.1016/j.talanta.2016.07.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2016] [Revised: 06/28/2016] [Accepted: 07/03/2016] [Indexed: 01/09/2023]
|
19
|
Biomedical analytical monitor of artificial kidney operation: Monitoring of creatinine removal. J Pharm Biomed Anal 2016; 128:28-34. [DOI: 10.1016/j.jpba.2016.04.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 04/13/2016] [Accepted: 04/16/2016] [Indexed: 11/26/2022]
|
20
|
Biomedical monitoring of phosphate removal by hemodialysis. J Pharm Biomed Anal 2016; 126:9-13. [DOI: 10.1016/j.jpba.2016.04.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 04/20/2016] [Accepted: 04/21/2016] [Indexed: 10/21/2022]
|
21
|
Bianalyte multicommutated flow analysis system for microproteinuria diagnostics. Talanta 2016; 148:707-11. [DOI: 10.1016/j.talanta.2015.04.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 03/24/2015] [Accepted: 04/04/2015] [Indexed: 01/27/2023]
|
22
|
Multicommutated flow analysis system based on fluorescence microdetectors for simultaneous determination of phosphate and calcium ions in human serum. Talanta 2015; 144:184-8. [DOI: 10.1016/j.talanta.2015.06.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Revised: 05/28/2015] [Accepted: 06/02/2015] [Indexed: 10/23/2022]
|
23
|
Towards optoelectronic urea biosensors. Anal Bioanal Chem 2015; 407:1807-12. [PMID: 25619983 PMCID: PMC4336418 DOI: 10.1007/s00216-014-8434-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Revised: 12/14/2014] [Accepted: 12/18/2014] [Indexed: 12/01/2022]
Abstract
Integration of immobilized enzymes with light-emitting diodes (LEDs) leads to the development of optoelectronic enzyme-based biosensors. In this work, urease, used as a model enzyme, immobilized in the form of an open-tubular microbioreactor or biosensing membrane that has been integrated with two red LEDs. It forms complete, fiberless, miniaturized, and extremely economic biooptoelectronic devices useful for nonstationary measurements under flow analysis conditions. Both enzyme-based biodevices, operating according to the paired emitter detector diode (PEDD) principle, allow relatively fast, highly sensitive, and well-reproducible urea detection in the millimolar range of concentrations. Potential analytical applications of the developed urea bioPEDDs have been announced. Both presented constructions will be easily adapted for the development of other optoelectronic biosensors exploring various enzyme-based schemes of biodetection.
Collapse
|
24
|
Abstract
In this contribution, a multicommutated flow analysis (MCFA) system for immunoprecipitation assays is presented.
Collapse
|
25
|
Multicommutated flow analysis system for determination of total protein in cerebrospinal fluid. Talanta 2014; 128:38-43. [DOI: 10.1016/j.talanta.2014.04.047] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 04/07/2014] [Accepted: 04/15/2014] [Indexed: 11/24/2022]
|
26
|
A bimodal optoelectronic flow-through detector for phosphate determination. Talanta 2014; 128:211-4. [DOI: 10.1016/j.talanta.2014.04.086] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 04/24/2014] [Accepted: 04/29/2014] [Indexed: 11/25/2022]
|
27
|
Biparametric multicommutated flow analysis system for determination of human serum phosphoesterase activity. Anal Chim Acta 2013; 797:57-63. [DOI: 10.1016/j.aca.2013.08.047] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 07/21/2013] [Accepted: 08/28/2013] [Indexed: 11/24/2022]
|
28
|
Multicommutated flow analysis system for determination of creatinine in physiological fluids by Jaffe method. Anal Chim Acta 2013; 787:118-25. [DOI: 10.1016/j.aca.2013.05.052] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 05/22/2013] [Accepted: 05/30/2013] [Indexed: 12/14/2022]
|
29
|
Urea sensors based on PVC membrane pH electrode. Talanta 2012; 41:1201-5. [PMID: 18966057 DOI: 10.1016/0039-9140(94)80092-8] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/1993] [Revised: 07/19/1993] [Accepted: 08/03/1993] [Indexed: 11/18/2022]
Abstract
Several procedures of urease immobilization on the surface of the polymeric membrane pH electrode with tri-n-dodecylamine as a neutral carrier were compared. The best results were obtained for the urea sensor with covalently bound urease. The sensor characteristics including the effect of buffer, pH and concentration and the effect of stirring rate are presented. These effects are in good agreement with theoretical expectations.
Collapse
|
30
|
Low-cost optical detectors and flow systems for protein determination. Talanta 2012; 96:121-6. [DOI: 10.1016/j.talanta.2012.01.061] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2011] [Revised: 01/24/2012] [Accepted: 01/31/2012] [Indexed: 01/17/2023]
|
31
|
Serum alkaline phosphatase assay with paired emitter detector diode. Talanta 2012; 96:127-31. [DOI: 10.1016/j.talanta.2012.01.031] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Revised: 12/18/2011] [Accepted: 01/14/2012] [Indexed: 11/17/2022]
|
32
|
Towards the development of a miniaturized fiberless optofluidic biosensor for glucose. Talanta 2012; 96:113-20. [DOI: 10.1016/j.talanta.2011.11.021] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 10/31/2011] [Accepted: 11/04/2011] [Indexed: 10/15/2022]
|
33
|
Compact optoelectronic flow-through device for fluorometric determination of calcium ions. Talanta 2012; 93:106-10. [DOI: 10.1016/j.talanta.2012.01.055] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 01/22/2012] [Accepted: 01/29/2012] [Indexed: 10/14/2022]
|
34
|
Fluorimetric detector and sensor for flow analysis made of light emitting diodes. Anal Chim Acta 2012; 721:92-6. [DOI: 10.1016/j.aca.2012.01.029] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2011] [Revised: 01/12/2012] [Accepted: 01/16/2012] [Indexed: 11/25/2022]
|
35
|
|
36
|
Hemoglobin determination with paired emitter detector diode. Anal Bioanal Chem 2010; 399:3293-7. [PMID: 21046074 PMCID: PMC3044230 DOI: 10.1007/s00216-010-4358-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2010] [Revised: 10/12/2010] [Accepted: 10/18/2010] [Indexed: 11/07/2022]
Abstract
Two ordinary green light-emitting diodes used as light emitter and detector coupled with simple voltmeter form a complete, cost-effective prototype of a photometric hemoglobinometer. The device has been optimized for cuvette assays of total hemoglobin (Hb) in diluted blood using three different chemical methods recommended for the needs of clinical analysis (namely Drabkin, lauryl sulfate, and dithionite methods). The utility of developed device for real analytics has been validated by the assays of total Hb content in human blood. The results of analysis are fully compatible with those obtained using clinically recommended method and clinical analyzer.
Collapse
|
37
|
A concept of dual optical detection using three light emitting diodes. Talanta 2010; 82:422-5. [DOI: 10.1016/j.talanta.2010.04.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2009] [Revised: 04/06/2010] [Accepted: 04/16/2010] [Indexed: 11/29/2022]
|
38
|
Poly(vinyl chloride) tubing with covalently bound alkaline phosphatase and alternative approach for investigations of open-tubular bioreactors. Anal Biochem 2010; 400:151-3. [DOI: 10.1016/j.ab.2010.01.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2009] [Revised: 01/12/2010] [Accepted: 01/13/2010] [Indexed: 10/19/2022]
|
39
|
A single standard calibration module for flow analysis systems based on solenoid microdevices. Talanta 2009; 79:205-10. [DOI: 10.1016/j.talanta.2009.03.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2008] [Revised: 03/06/2009] [Accepted: 03/12/2009] [Indexed: 10/21/2022]
|
40
|
|
41
|
An automated potentiometric assay for acid phosphatase. Anal Biochem 2008; 381:169-71. [DOI: 10.1016/j.ab.2008.06.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2008] [Revised: 06/05/2008] [Accepted: 06/08/2008] [Indexed: 11/28/2022]
|
42
|
Abstract
According to the developed model based on Shockley equation and the Lambert-Beer law, PEDD-based photometric devices generate a potentiometric analytical signal that is directly proportional to the analyte concentration.
Collapse
|
43
|
|
44
|
Recent developments in potentiometric biosensors for biomedical analysis. Anal Chim Acta 2007; 599:7-15. [PMID: 17765058 DOI: 10.1016/j.aca.2007.08.003] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2007] [Revised: 07/30/2007] [Accepted: 08/02/2007] [Indexed: 11/18/2022]
Abstract
A large variety of potentiometric biosensors is developed using biocatalytic and bioaffinity-based biosensing schemes. However, only few of them could be applied for the biomedical analysis. The most promising are those for the detection of main products of protein metabolism, namely urea and creatinine. A novel group of potentiometric biosensors is constituted by bioaffinity-based devices that could be used for immunoassays or genoanalysis. This paper reviews the recent trends in these fields as well as discusses advantages, limitations and pitfalls of the developed biosensors. Some potentiometric biosensors useful for real biomedical analysis are reported in detail.
Collapse
|
45
|
Potentiometric flow-injection system for determination of alkaline phosphatase in human serum. Anal Chim Acta 2007; 600:194-8. [PMID: 17903484 DOI: 10.1016/j.aca.2007.02.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2006] [Revised: 02/09/2007] [Accepted: 02/13/2007] [Indexed: 10/23/2022]
Abstract
A flow-injection system for detection of alkaline phosphatase (ALP) activity in human serum samples has been developed. As a specific and inexpensive ALP substrate for this kinetic assay monofluorophosphate (MFP) was applied. For detection of fluoride ions, generated in the course of the biocatalytic hydrolysis of MFP, conventional fluoride ion-selective electrode based on LaF(3)-crystalline membrane was applied. After optimization the system allows analysis of human serum with high selectivity and relatively short time of analysis (5-6 samples h(-1)). Volume of serum required for analysis is 0.05 mL. The system is useful for determination of the enzyme activity in human serum samples at physiological and pathological levels as well as for detection of isoenzymatic forms of ALP.
Collapse
|
46
|
Flow injection system for potentiometric determination of alkaline phosphatase inhibitors. Anal Chim Acta 2006; 577:134-9. [PMID: 17723664 DOI: 10.1016/j.aca.2006.05.100] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2006] [Revised: 05/10/2006] [Accepted: 05/14/2006] [Indexed: 11/23/2022]
Abstract
A simple flow injection system for potentiometric detection of alkaline phosphatase (ALP) activity has been developed and adapted for determination of selected inhibitors of this enzyme. In this system monofluorophosphate (MFP) has been applied as a specific ALP substrate. The use of this substrate enables application of fluoride ion selective electrode (FISE) as a detector of the product of the enzyme catalyzed reaction. Moreover, chemical stability and low cost of MFP enables the use of the substrate as a component of the carrier. This way, fluoride ions contained in this substrate define and stabilize baseline signal generated by the detector. Effects from several potential ALP inhibitors and interfering species were studied and discussed. The system allows inhibitive detection of beryllium and vanadate ions at ppb levels with relatively high selectivity, short time of analysis and high throughput of the system (near 8 samples h(-1)).
Collapse
|
47
|
pH-metric detection of alkaline phosphatase activity as a novel biosensing platform. Talanta 2006; 68:1020-5. [DOI: 10.1016/j.talanta.2005.07.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2005] [Revised: 05/25/2005] [Accepted: 07/05/2005] [Indexed: 10/25/2022]
|
48
|
Strip bioelectrochemical cell for potentiometric measurements fabricated by screen-printing. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.02.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
49
|
|
50
|
|