1
|
The rapid separation and characterization of sulfates of tyrosine and its metabolites in reaction mixtures and human urine using a cyclic ion mobility device and mass spectrometry. J Chromatogr A 2024; 1715:464597. [PMID: 38183784 DOI: 10.1016/j.chroma.2023.464597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/13/2023] [Accepted: 12/19/2023] [Indexed: 01/08/2024]
Abstract
Ion mobility (IM) separations, especially when combined with mass spectrometry, offer the opportunity for the rapid analysis and characterization of mixtures. However, the limited resolution afforded by many IM systems means that in practice applications may be limited. Here we have employed an IM separation on a high-resolution cyclic IM device with MS/MS to separate and characterize mixtures of sulfated isomers of tyrosine and associated metabolites containing multiple sulfated isoforms present in reaction mixtures. The cIMS device allowed ions, not resolved using a single pass, to be subjected to multiple passes, enabling the resolution of those with similar collision cross sections (CCS). Predicted single pass CCS values calculated for the isomers likely to be present in these mixtures showed only small differences between them, ranging between of between 0.1 - 0.7 % depending on structure. These small differences highlight the high degree of mobility resolution required for separating the isomers. Experimentally different isoforms of tyrosine sulfate and sulfated tyrosine metabolites could be sufficiently resolved via multipass separations (3-35 passes). This degree of separation provided resolving powers of up to 384 CCS/ΔCCS for sulfated dopamine which enabled good MS/MS spectra to be generated. In human urine the presence of a single sulfated form of tyrosine was detected and identified as the O-sulfate after 3 passes based on the synthetic standard. Of the other tyrosine-related sulfates for which synthetic standards had been prepared only dopamine sulfate was detected in this sample.
Collapse
|
2
|
Increasing coverage of the urinary polar metabolome using ultra high-performance hydrophobic interaction liquid chromatography combined with linear and cyclic travelling wave ion mobility and mass spectrometry. J Chromatogr A 2024; 1714:464537. [PMID: 38157664 DOI: 10.1016/j.chroma.2023.464537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/23/2023] [Accepted: 11/25/2023] [Indexed: 01/03/2024]
Abstract
The use of HILIC-based separations for the analysis of polar metabolites in metabolic phenotyping studies is well established. Here, we demonstrate the increased coverage of the polar metabolome obtained by travelling wave (TW) ion mobility (IM) instruments combined with HILIC and mass spectrometry (MS) for metabotyping rat and mouse urine samples. Profiling was performed using either a linear TW IM-MS based instrument with a path length of 40 cm or an instrument with a cyclic travelling wave analyser (cIM) with a path length of 95 cm. Due to the added resolution afforded by using both the linear and cyclic IM geometries with MS detection (IM-MS) significant increases in feature count (m/z-tR pairs) were generally obtained compared to HILIC-MS alone. In addition, the use of both linear and cyclic IM-MS improved the quality of the mass spectra obtained as a result of the separation of co-eluting analytes. As would be expected from the increased path length of the cyclic IM-MS instrument compared to the linear device, the largest gains in feature detection were obtained for the HILIC-cIM-MS combination. By increasing the resolution of coeluting components, the cyclic IM-MS instrumentation also provided the largest improvement in the quality of the mass spectral data obtained. When applied to mouse urines obtained from both control and gefitinib-dosed mice, time-related changes were detected in those obtained from the treated animals that were not seen in the controls. Polar metabolites affected by drug administration included, but were not limited to, hypoxanthine, 1,3-dimethyluracil and acetylcarnitine. The changes seen in the relative concentrations of these endogenous metabolites appeared to be related to drug concentrations in the plasma and urine suggesting a pharmacometabodynamic link.
Collapse
|
3
|
Development of a single mobile phase for LC-IM-MS-based discovery lipidomics and metabolic phenotyping: Application to methapyrilene hepatotoxicity in the rat. J Chromatogr A 2024; 1714:464552. [PMID: 38113579 DOI: 10.1016/j.chroma.2023.464552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/18/2023] [Accepted: 11/30/2023] [Indexed: 12/21/2023]
Abstract
The untargeted global profiling of endogenous metabolites and lipids has the potential to increase knowledge and understanding in many areas of biology. LC-MS/MS is a key technology for such analyses however, several different LC methodologies, using different mobile phase compositions, are required to cover the diversity in polarity and analyte structure encountered in biological samples. Most notably many lipid screening methods make use of isopropanol (IPA) as a major component of mobile phases employed for comprehensive lipidomic profiling. In order to increase laboratory efficiency, and minimize opportunities for errors, a suite of methods, based on a single acetonitrile (ACN)-aqueous buffer mobile phase combination, has been developed. This mobile phase can be used for hydrophobic interaction liquid chromatography on an amide stationary phase (for polar analytes), reversed-phase (RP) LC analysis on a C8 stationary phase (for moderately polar-non-polar compounds) and RPLC using a CSH phenyl-hexyl bonded column (for lipids). All of these sub 10 minute separations had good throughput and reproducibility with CV's of analyte response <25 % whilst eliminating the need for complex mobile phase preparation and the use of IPA as an organic modifier for lipidomics. Advantages of removing IPA and replacing it with the ACN-based method were a 58 % increase in peak capacity for lipids, with improved resolution for the di- and triglycerides and cholesterol esters compared to current methods. Compared to the IPA-containing solvent system the ACN-based mobile phase also resulted in a 61 % increase in lipid feature detection. The utility of this "universal" mobile phase approach was demonstrated by its application to a rat toxicology study investigating the consequences of methapyrilene administration through on the endogenous metabolite profiles of plasma and urine. Methapyrilene and its metabolites were also profiled in these samples.
Collapse
|
4
|
Understanding mobile phase buffer composition and chemical structure effects on electrospray ionization mass spectrometry response. J Chromatogr A 2023; 1696:463966. [PMID: 37054638 DOI: 10.1016/j.chroma.2023.463966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/01/2023] [Accepted: 04/03/2023] [Indexed: 04/15/2023]
Abstract
Mobile phase selection is of critical importance in liquid chromatography - mass spectrometry (LC-MS) based studies, since it affects retention, chromatographic selectivity, ionization, limits of detection and quantification, and linear dynamic range. Generalized LC-MS mobile phase selection criteria, suitable for a broad class of chemical compounds, do not exist thus far. Here we have performed a large-scale qualitative assessment of the effect of solvent composition used for reversed-phase LC separations on electrospray ionization (ESI) response for 240 small molecular weight drugs, representing various chemical compound classes. Of these 240 analytes 224 were detectable using ESI. The main chemical structural features affecting ESI response were found to all be surface area or surface charge-related. Mobile phase composition was found to be less differentiating, although for some compounds a pH effect was noted. Unsurprisingly, chemical structure was found to be the dominant factor for ESI response for the majority of the investigated analytes, representing about 85% of the replicating detectable complement of the sample data set. A weak correlation between ESI response and structure complexity was observed. Solvents based on isopropanol, and those containing phosphoric or di- and trifluoracetic acids, performed relatively poorly in terms of chromatographic or ESI response, whilst the best performing 'generic' LC solvents were based on methanol, acetonitrile using formic acid and ammonium acetate as buffer components, consistent with current practice in many laboratories.
Collapse
|
5
|
Investigation of the Pharmacokinetics and Metabolic Fate of Fasiglifam (TAK-875) in Male and Female Rats Following Oral and Intravenous Administration. Xenobiotica 2023; 53:93-105. [PMID: 36794569 DOI: 10.1080/00498254.2023.2179952] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
The metabolism and pharmacokinetics of fasiglifam (TAK-875, 2-[(3S)-6-[[3-[2,6-dimethyl-4-(3-methylsulfonylpropoxy)phenyl]phenyl]methoxy]-2,3-dihydro-1-benzofuran-3-yl]acetic acid), a selective free fatty acid receptor 1 (FFAR1)/GPR40 agonist, were studied following intravenous (5 mg/kg) and oral administration (10 and 50 mg/kg) to male and female Sprague Dawley rats.Following intravenous dosing at 5 mg/kg, peak observed plasma concentrations of 8.8/9.2 μg/ml were seen in male and female rats respectively.Following oral dosing, peak plasma concentrations at 1 h of ca. 12.4/12.9 μg/ml for 10 mg/kg and 76.2/83.7 μg/ml for 50 mg/kg doses were obtained for male and female rats respectively. Drug concentrations then declined in the plasma of both sexes with t1/2's of 12.4 (male) and 11.2 h (female). Oral bioavailability was estimated to be 85-120% in males and females at both dose levels.Urinary excretion was low, but in a significant sex-related difference, female rats eliminated ca. 10-fold more drug-related material by this route.Fasiglifam was the principal drug-related compound in plasma, with 15 metabolites, including the acyl glucuronide, also detected. In addition to previously identified metabolites, a novel biotransformation, that produced a side-chain shortened metabolite via elimination of CH2 from the acetyl side chain was noted with implications for drug toxicity.
Collapse
|
6
|
Ensuring Fact-Based Metabolite Identification in Liquid Chromatography-Mass Spectrometry-Based Metabolomics. Anal Chem 2023; 95:3909-3916. [PMID: 36791228 PMCID: PMC9979140 DOI: 10.1021/acs.analchem.2c05192] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
Metabolite identification represents a major bottleneck in contemporary metabolomics research and a step where critical errors may occur and pass unnoticed. This is especially the case for studies employing liquid chromatography-mass spectrometry technology, where there is increased concern on the validity of the proposed identities. In the present perspective article, we describe the issue and categorize the errors into two types: identities that show poor biological plausibility and identities that do not comply with chromatographic data and thus to physicochemical properties (usually hydrophobicity/hydrophilicity) of the proposed molecule. We discuss the problem, present characteristic examples, and propose measures to improve the situation.
Collapse
|
7
|
Advances in high throughput LC/MS based metabolomics: A review. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
8
|
High Throughput LC-MS Platform for Large Scale Screening of Bioactive Polar Lipids in Human Plasma and Serum. J Proteome Res 2022; 21:2596-2608. [PMID: 36264332 DOI: 10.1021/acs.jproteome.2c00297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Lipids play a key role in many biological processes, and their accurate measurement is critical to unraveling the biology of diseases and human health. A high throughput HILIC-based (LC-MS) method for the semiquantitative screening of over 2000 lipids, based on over 4000 MRM transitions, was devised to produce an accessible and robust lipidomic screen for phospholipids in human plasma/serum. This methodology integrates many of the advantages of global lipid analysis with those of targeted approaches. Having used the method as an initial "wide class" screen, it can then be easily adapted for a more targeted analysis and quantification of key, dysregulated lipids. Robustness was assessed using 1550 continuous injections of plasma extracts onto a single column and via the evaluation of columns from 5 different batches of stationary phase. Initial screens in positive (239 lipids, 431 MRM transitions) and negative electrospray ionization (ESI) mode (232 lipids, 446 MRM transitions) were assessed for reproducibility, sensitivity, and dynamic range using analysis times of 8 min. The total number of lipids monitored using these screening methods was 433 with an overlap of 38 lipids in both modes. A polarity switching method for accurate quantification, using the same LC conditions, was assessed for intra- and interday reproducibility, accuracy, dynamic range, stability, carryover, dilution integrity, and matrix interferences and found to be acceptable. This polarity switching method was then applied to lipids important in the stratification of human prostate cancer samples.
Collapse
|
9
|
Access to the Phospho-proteome via the Mitigation of Peptide-Metal Interactions. J Chromatogr A 2022; 1673:463024. [DOI: 10.1016/j.chroma.2022.463024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/21/2022] [Accepted: 04/03/2022] [Indexed: 10/18/2022]
|
10
|
High Performance Reversed-Phase Thin-Layer Chromatography-Desorption Electrospray Ionisation - Time of Flight High Resolution Mass Spectrometric Detection and Imaging (HPTLC/DESI/ToFMS) of Phytoecdysteroids. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1200:123265. [DOI: 10.1016/j.jchromb.2022.123265] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 04/05/2022] [Accepted: 04/24/2022] [Indexed: 02/04/2023]
|
11
|
Abstract
Reversed-phase UHPLC-MS is extensively employed for both the profiling of biological fluids and tissues to characterize lipid dysregulation in disease and toxicological studies. With conventional LC-MS systems the chromatographic performance and throughput are limited due to dispersion from the fluidic connections as well as radial and longitudinal thermal gradients in the LC column. In this study vacuum jacketed columns (VJC), positioned at the source of the mass spectrometer, were applied to the lipidomic analysis of plasma extracts. Compared to conventional UHPLC, the VJC-based methods offered greater resolution, faster analysis, and improved peak intensity. For a 5 min VJC analysis, the peak capacity increased by 66%, peak tailing reduced by up to 34%, and the number of lipids detected increased by 30% compared to conventional UHPLC. The narrower peaks, and thus increased resolution, compared to the conventional system resulted in a 2-fold increase in peak intensity as well a significant improvement in MS and MS/MS spectral quality resulting in a 22% increase in the number of lipids identified. When applied to mouse plasma samples, reproducibility of the lipid intensities in the pooled QC ranged from 1.8-12%, with no related drift in tR observed.
Collapse
|
12
|
Abstract
In UHPLC, frictional heating from the eluent flowing through the column at pressures of ca. 10-15 Kpsi causes radial diffusion via temperature differences between the center of the column and its walls. Longitudinal dispersion also occurs due to temperature gradients between the inlet and outlet. These effects cause band broadening but can be mitigated via a combination of vacuum jacketed stainless steel tubing, reduced column end nut mass, and a constant temperature in the column from heating the inlet fitting. Here, vacuum jacketed column (VJC) technology, employing a novel column housing located on the source of the mass spectrometer and minimized tubing from the column outlet to the electrospray probe, was applied to profiling metabolites in urine. For a 75 s reversed-phase gradient separation, the average peak widths for endogenous compounds in urine were 1.2 and 0.6 s for conventional LC/MS and VJC systems, respectively. The peak tailing factor was reduced from 1.25 to 1.13 when using the VJC system compared to conventional UHPLC, and the peak capacity increased from 65 to 120, with a 25% increase in features detected in urine. The increased resolving power of the VJC system reduced co-elution, simplifying MS and MS/MS spectra, providing a more confident metabolite identification. The increased LC performance also gave more intense MS peaks, with a 10-120% increase in response, improving the quality of the MS data and detection limits. Reducing the LC gradient duration to 37 s gave peak widths of ca. 0.4 s and a peak capacity of 84.
Collapse
|
13
|
Proteomic consequences of the deletion of cytochrome P450 (CYP450) reductase in mice. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122803. [PMID: 34218094 DOI: 10.1016/j.jchromb.2021.122803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/19/2021] [Accepted: 05/23/2021] [Indexed: 11/16/2022]
Abstract
Microsomal cytochrome P450 (CYP450) reductase enzymes play a major role in drug and xenobiotic metabolism. Mice which are deficient in hepatic CYP450 reductase serve as excellent models in understanding CYP450 drug metabolism and alterations in the underlying biology and function of these enzymes. A reversed-phase nano-bore UPLC-MS-based proteomic analysis, using an untargeted data independent approach (DIA), has been utilized for liver tissue extracts to evaluate differences between the proteomes of C57Bl6 wild type (WT) and hepatic P450 reductase mice (HRN™). Statistically curated, differentially expressed protein groups highlighted a variety of molecular and biological functions, including binding and catalytic related activities. Thus, elevations were seen for a number of CYP450 enzymes (Cyp2a5; Cyp2b10; Cyp2b19; Cyp2d26; Cyp2a5, Cyp2e1) in the liver extracts of HRN animals. In addition, the major urinary protein 2 (Mup2) was found to be present only in the livers of the HRN group, whilst enoyl-CoA hydratase domain-containing protein 2 (Echdc2) was similarly unique to the the WT livers. Pathway enrichment analysis of the WT liver data indicated perturbations of lipid and energy related pathways, which included bile acid biosynthesis, fatty acid omega oxidation and tricarboxylic acid (TCA) cycle as examples.
Collapse
|
14
|
Improving LC/MS/MS-based bioanalytical method performance and sensitivity via a hybrid surface barrier to mitigate analyte - Metal surface interactions. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122825. [PMID: 34218093 DOI: 10.1016/j.jchromb.2021.122825] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 06/01/2021] [Accepted: 06/03/2021] [Indexed: 12/16/2022]
Abstract
The accurate determination of the pharmacokinetics (PK) of a candidate drug molecule is critical in both drug discovery and development. Over the last 30 years, the sensitivity and selectivity of LC/MS has resulted in it being established as the technology of choice for these studies. However, unwanted chemical interactions between analyte(s) and the metal components in a chromatography system can result in poor peak shape and reduction in signal response, which can adversely affect the analysis of low concentrations of drugs and their metabolites in biological samples. This study evaluated the benefits of employing an inert hybrid surface technology (HST) applied to the metallic components in the LC flow path, column frits and column wall to mitigate these interactions. The results obtained were compared with that of an identical conventional LC for the bioanalysis of two steroid phosphate drugs (dexamethasone phosphate and hydrocortisone phosphate) and an epidermal growth factor receptor (EGFR) inhibitor (gefitinib) in human plasma. The results showed that for the two steroid phosphates, the peak width was reduced by 20%, peak tailing factors reduced by up to 30% and the assay sensitivity improved by factors of 7.5 and 10. This resulted in a significant improvement in the limit of detection. The new LC system also improved the reproducibility of peak integration for gefitinib, thereby reducing assay coefficients of variation (%CV) from greater than 10% to less than 5% at the lower limit of quantification.
Collapse
|
15
|
Use of Cyclic Ion Mobility Spectrometry (cIM)-Mass Spectrometry to Study the Intramolecular Transacylation of Diclofenac Acyl Glucuronide. Anal Chem 2021; 93:7413-7421. [PMID: 33984239 DOI: 10.1021/acs.analchem.0c04487] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
1-β-O-Acyl-glucuronides (AGs) are common metabolites of carboxylic acid-containing xenobiotics, including, e.g., many nonsteroidal anti-inflammatory drugs (NSAIDs). They are of concern to regulatory authorities because of the association of these metabolites with the hepatotoxicity that has resulted in drug withdrawal. One factor in assessing the potential risk posed by AGs is the rate of transacylation of the biosynthetic 1-β-O-acyl form to the 2-, 3-, and 4-O-acyl isomers. While transacylation can be measured using 1H NMR spectroscopy or liquid chromatography-mass spectrometry (LC-MS), the process can be time consuming and involve significant method development. The separation of these positional isomers by ion mobility spectrometry (IMS) has the potential to allow their rapid analysis, but conventional instruments lacked the resolving power to do this. Prediction of the collision cross section (CCS) using a machine learning model suggested that greater IMS resolution might be of use in this area. Cyclic IMS was evaluated for separating mixtures of isomeric AGs of diclofenac and was compared with a conventional ultraperformance liquid chromatography (UPLC)-MS method as a means for studying transacylation kinetics. The resolution of isomeric AGs was not seen using a conventional traveling wave IMS device; however, separation was seen after several passes around a cyclic IMS. The cyclic IMS enabled the degradation of the 1-β-O-acyl-isomer to be analyzed much more rapidly than by LC-MS. The ability of cyclic IMS to monitor the rate of AG transacylation at different pH values, without the need for a prior chromatographic separation, should allow high-throughput, real-time, monitoring of these types of reactions.
Collapse
|
16
|
Hybrid organic/inorganic hybrid surface technology for increasing the performance of LC/MS(MS)-based drug metabolite identification studies: Application to gefitinib and metabolites in mouse plasma and urine. J Pharm Biomed Anal 2021; 200:114076. [PMID: 33892395 DOI: 10.1016/j.jpba.2021.114076] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/29/2021] [Accepted: 04/12/2021] [Indexed: 11/18/2022]
Abstract
The detection, identification and quantification of drug metabolites plays a key role in drug discovery and development. Liquid chromatography (LC) coupled to mass spectrometry (MS) has become the primary technology for these studies due to its sensitivity and specificity. However, the presence of transition metals in the chromatography system and columns can result in non-specific and unwanted interactions with the drug and/or its metabolites, via electron-pair donation, leading to poor chromatography and analyte loss. The use of a hybrid organic/inorganic surface applied to the metal surfaces of the chromatography system and column has been demonstrated to reduce or eliminate these effects. When employed for the analysis of mouse urine, derived from the oral dosing of mice with the EGFR inhibitor gefitinib, we observed more symmetrical LC peaks. This resulted in a 33 % improvement in peak capacity for a 10 min reversed - phase gradient separation, a two-fold increase in MS response, cleaner MS spectra and improved peak response reproducibility. This hybrid surface barrier appears to offer significant advantages in the analysis of low-concentration metabolites, potentially facilitating the accurate determination of the elimination phase of the pharmacokinetic (PK) curve and detection of drug metabolites in microdosing or microsampling studies.
Collapse
|
17
|
High-Throughput Microbore Ultrahigh-Performance Liquid Chromatography-Ion Mobility-Enabled-Mass Spectrometry-Based Proteomics Methodology for the Exploratory Analysis of Serum Samples from Large Cohort Studies. J Proteome Res 2021; 20:1705-1715. [PMID: 33566619 DOI: 10.1021/acs.jproteome.0c00821] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The deployment of proteomic analysis in clinical studies represents a significant opportunity to detect and validate biomarkers in translational medicine, improve disease understanding, and provide baseline information on population health. However, comprehensive proteome studies usually employ nanoscale chromatography and often require several hours of analysis/sample. Here, we describe a high-throughput liquid chromatography tandem mass spectrometry (LC/MS/MS) methodology using 1 mm scale chromatography requiring only 15 min/sample, coupled to ion mobility-enabled mass spectrometry. The short run time effected a 6-fold increase in productivity compared with nanoscale LC/MS. The method demonstrated excellent reproducibility with retention time coefficient of variations of less than 0.05% and peak area reproducibility ranging from 5 to 15%. The 1 mm system produced similar chromatographic peak capacity values to the nanoscale miniaturized system, detecting 90% of the Escherichia coli proteins identified by the 75 μm LC/MS system (albeit based on only 75% of the peptides found by the latter). Application to the analysis of serum samples from a human prostate cancer study group resulted in the identification of a total of 533 proteins revealing the differential expression of proteins linked to patients receiving hormone-radiotherapy or undergoing surgery.
Collapse
|
18
|
Rapid determination of the pharmacokinetics and metabolic fate of gefitinib in the mouse using a combination of UPLC/MS/MS, UPLC/QToF/MS, and ion mobility (IM)-enabled UPLC/QToF/MS. Xenobiotica 2021; 51:434-446. [PMID: 33280466 DOI: 10.1080/00498254.2020.1859643] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The metabolism and pharmacokinetics of gefitinib (Iressa®, N-(3-chloro-4-fluorophenyl)-7-methoxy-6-(3-morpholino-propoxy)quinazolin-4-amine), a selective thymidylate kinase inhibitor for the epidermal growth factor receptor (EGFR), was studied after IV and PO administration to male C57BL6 mice at 10 and 50 mg/kg respectively.The pharmacokinetics and metabolism of gefitinib were investigated using a range of rapid UHPLC-MS and UHPLC-IM-HRMS methods, using both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC), to rapidly determine the drugs pharmacokinetics and metabolic fate.Rapid oral absorption resulted in peak plasma concentrations at 1 h of ca. 7 µg/mL, that declined with a half-life of 3.8 h (2.6 h for the IV route), and providing an estimated oral bioavailability of 53%. Gefitinib itself was the major circulating drug-related compound in plasma extracts, with a total of 11 metabolites identified.The urinary profiles determined using both HILIC and RP-UPLC-IM-MS detected gefitinib and 10 metabolites or 15 metabolites respectively including the detection of a number of novel glucuronide conjugates.Despite rapid, sub 5 min, LC profiling methods being employed metabolite coverage was shown to be high and compared well with that of previous studies.
Collapse
|
19
|
UHPLC-MS-Based Lipidomic and Metabonomic Investigation of the Metabolic Phenotypes of Wild Type and Hepatic CYP Reductase Null (HRN) Mice. J Pharm Biomed Anal 2020; 186:113318. [DOI: 10.1016/j.jpba.2020.113318] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 04/10/2020] [Accepted: 04/14/2020] [Indexed: 02/05/2023]
|
20
|
Metabolic Phenotyping Using UPLC–MS and Rapid Microbore UPLC–IM–MS: Determination of the Effect of Different Dietary Regimes on the Urinary Metabolome of the Rat. Chromatographia 2020. [DOI: 10.1007/s10337-020-03900-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
AbstractA rapid reversed-phase gradient method employing a 50 mm × 1 mm i.d., C18 microbore column, combined with ion mobility and high-resolution mass spectrometry, was applied to the metabolic phenotyping of urine samples obtained from rats receiving different diets. This method was directly compared to a “conventional” method employing a 150 × 2.1 mm i.d. column packed with the same C18 bonded phase using the same samples. Multivariate statistical analysis of the resulting data showed similar class discrimination for both microbore and conventional methods, despite the detection of fewer mass/retention time features by the former. Multivariate statistical analysis highlighted a number of ions that represented diet-specific markers in the samples. Several of these were then identified using the combination of mass, ion-mobility-derived collision cross section and retention time including N-acetylglutamate, urocanic acid, and xanthurenic acid. Kynurenic acid was tentatively identified based on mass and ion mobility data.
Collapse
|
21
|
Rapid profiling method for the analysis of lipids in human plasma using ion mobility enabled-reversed phase-ultra high performance liquid chromatography/mass spectrometry. J Chromatogr A 2020; 1611:460597. [DOI: 10.1016/j.chroma.2019.460597] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Revised: 09/19/2019] [Accepted: 10/03/2019] [Indexed: 12/22/2022]
|
22
|
Application of a Novel Mass Spectral Data Acquisition Approach to Lipidomic Analysis of Liver Extracts from Sitaxentan-Treated Liver-Humanized PXB Mice. J Proteome Res 2019; 18:4055-4064. [DOI: 10.1021/acs.jproteome.9b00334] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
23
|
A comparison of collision cross section values obtained via travelling wave ion mobility-mass spectrometry and ultra high performance liquid chromatography-ion mobility-mass spectrometry: Application to the characterisation of metabolites in rat urine. J Chromatogr A 2019; 1602:386-396. [DOI: 10.1016/j.chroma.2019.06.056] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/24/2019] [Accepted: 06/26/2019] [Indexed: 01/01/2023]
|
24
|
Abstract 4532: Differential protein and metabolite regulation in urothelial carcinoma highlights changes in immunity and receptor signaling pathways. Cancer Res 2019. [DOI: 10.1158/1538-7445.am2019-4532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Bladder cancer is ranked as one of the tumours posing high morbidity and mortality, with a pathogenesis which is still not well understood. A combination of genetic and lifestyle factors, including smoking, are known to contribute towards increasing the probability of encountering cancer. Here, we describe a multi-omic approach to reveal molecular factors that may be involved in these biomolecular processes. Plasma samples consisting of healthy controls and those from patients diagnosed with bladder cancer were prepared for proteomic, metabolomic and lipidomic analyses. Label-free LC-MS data were acquired using a QTof platform utilizing a data independent (DIA) workflow termed SONAR. Small molecule analysis consisted of using Progenesis QI for data processing to provide normalised values prior to statistical analysis. Unsupervised MVA of the data showed clear distinction between cohorts. OPLS-DA was used to filter for features of significant correlation and covariance prior to identification using metabolite and lipid specific databases. Identifications matching the following criteria, mass accuracy <5 ppm, ANOVA p <0.05, %CV <30 and fold change >2 were considered for further interrogation. SONAR-based analysis indicates that this method of data acquisition enabled over an order of magnitude more specificity than equivalent methodologies with the same resolution. Proteomic data were processed and searched against a Uniprot Homo sapien database, containing reviewed entries and limited to 1% FDR. Additionally, we also searched the data against a spectral library and comparatively analysed the results from both workflows. A number of significant proteins with differential regulation were exhibited for a number of protein groups involved in antigen and lipid binding. Proteins occurring in a minimum of two out of three replicates and with ANOVA p <0.05 were considered. Biological significance of the results was established by merging data from all three omic experiments and performing pathway analysis. A number of significant pathways including complement activation, B cell mediated immunity and receptor signalling were identified as key pathways.
Citation Format: Lee Gethings, Adam King, Andrew J. Peck, Robert S. Plumb. Differential protein and metabolite regulation in urothelial carcinoma highlights changes in immunity and receptor signaling pathways [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2019; 2019 Mar 29-Apr 3; Atlanta, GA. Philadelphia (PA): AACR; Cancer Res 2019;79(13 Suppl):Abstract nr 4532.
Collapse
|
25
|
Abstract 663: Diagnostic screen for lung cancer using high throughput metabolomics screen. Cancer Res 2019. [DOI: 10.1158/1538-7445.am2019-663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Lung cancer is one of the most common cancers in the world. It is a leading cause of cancer death in men and women in the United States, cigarette smoking being leading cause of lung cancer. There are two main types of lung cancer small cell and non-small cell lung cancer (NSCLC). The most common type being NSCLC which accounts for 80-85% of all reported cases. The ability to rapidly detect / diagnose lung cancer at an early stage is critical to successful treatment selection and patient survival.
The use of metabolic profiling in biomedical applications metabolic profiling is being deployed as a method for finding novel, mechanistic, biomarkers of disease with obvious potential for improving diagnosis, and patient stratification. Here we present a rapid, simple and reliable high throughput targeted LC/MS single platform, for the quantification/monitoring of small molecule metabolites, lipids and peptides. The methodology employs a single set of LC/MS conditions which facilitate TCA cycle, bile acids, biogenic amine, free fatty acids, acyl carnitines, lipids and 100 protein panel without need for user intervention.
Plasma from pilot cohort of lung cancer a health control samples were evaluated using this new methodology. The methodology showed excellent reproducibility and accuracy. The peptide analysis showed that 10 peptides were shown to be markers of lung cancer, these are listed in Table 1. Acylcarnitines were quantified over a range of 5 - 625ng/mL data showed that the C14:2 tetradecadienoyl carnitine and C16:1 palmitoleoyl carnitine were elevated in lung cancer samples whereas the C8:1 octenoyl carnitine level was reduced in the lung cancer samples . Although deoxycholic acid and chendeoxycholic acid appeared to be reduced in the lung cancer samples this was determined to be not statistically relevant. A total of 29 amino acids were measured during the analysis. Using t-test with p-value FDR cutoff adjusted to 0.01 the data clearly showed that sarcosine was highly over-expressed in lung cancer samples.
Table 1P02749Apolipoprotein HP19652Alpha-1-acid glycoprotein 2P68871Hemoglobin subunit betaP02671Fibrogen alpha chainP02656Apolipoprotein C-IIIP02750Leucine-rich alpha 2-glycoprotein (LRG)P00738HaptoglobinP02748Complement component C9P02763Alpha-1-acid glycoprotein 1P01011Alpha-1-antichymotrypsin
Note: This abstract was not presented at the meeting.
Citation Format: Robert S. Plumb, Lee Gethings, Andrew Peck. Diagnostic screen for lung cancer using high throughput metabolomics screen [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2019; 2019 Mar 29-Apr 3; Atlanta, GA. Philadelphia (PA): AACR; Cancer Res 2019;79(13 Suppl):Abstract nr 663.
Collapse
|
26
|
Untargeted LC/MS-based metabolic phenotyping (metabonomics/metabolomics): The state of the art. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1117:136-147. [PMID: 31009899 DOI: 10.1016/j.jchromb.2019.04.009] [Citation(s) in RCA: 90] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 04/01/2019] [Accepted: 04/03/2019] [Indexed: 12/25/2022]
Abstract
Liquid chromatography (LC) hyphenated to mass spectrometry is currently the most widely used means of determining metabolic phenotypes via both untargeted and targeted analysis. At present a range of analytical separations, including reversed-phase, hydrophilic interaction and ion-pair LC are employed to maximise metabolome coverage with ultra (high) performance liquid chromatography (UHPLC) increasingly displacing conventional high performance liquid chromatography because of the need for short analysis times and high peak capacity in such applications. However, it is widely recognized that these methodologies do not entirely solve the problems facing researchers trying to perform comprehensive metabolic phenotyping and in addition to these "routine" approaches there are continuing investigations of alternative separation methods including 2-dimensional/multi column approaches. These involve either new stationary phases or multidimensional combinations of the more conventional materials currently used, as well as application of miniaturization or "new" approaches such as supercritical HP and UHP- chromatographic separations. There is also a considerable amount of interest in the combination of chromatographic and ion mobility separations, with the latter providing both an increase in resolution and the potential to provide additional structural information via the determination of molecular collision cross section data. However, key problems remain to be solved including ensuring quality, comparability across different laboratories and the ever present difficulty of identifying unknowns.
Collapse
|
27
|
Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry with Electrospray Ionization Quantification of Tryptophan Metabolites and Markers of Gut Health in Serum and Plasma-Application to Clinical and Epidemiology Cohorts. Anal Chem 2019; 91:5207-5216. [PMID: 30848589 PMCID: PMC6503468 DOI: 10.1021/acs.analchem.8b05884] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
![]()
A targeted
ultrahigh-performance liquid chromatography tandem mass
spectrometry with electrospray ionization (UHPLC-ESI-MS/MS) method
has been developed for the quantification of tryptophan and its downstream
metabolites from the kynurenine and serotonin pathways. The assay
coverage also includes markers of gut health and inflammation, including
citrulline and neopterin. The method was designed in 96-well plate
format for application in multiday, multiplate clinical and epidemiology
population studies. A chromatographic cycle time of 7 min enables
the analysis of two 96-well plates in 24 h. To protect chromatographic
column lifespan, samples underwent a two-step extraction, using solvent
protein precipitation followed by delipidation via solid-phase extraction
(SPE). Analytical validation reported accuracy of each analyte <20%
for the lowest limit of quantification and <15% for all other quality
control (QC) levels. The analytical precision for each analyte was
2.1–12.9%. To test the applicability of the method to multiplate
and multiday preparations, a serum pool underwent periodic repeat
analysis during a run consisting of 18 plates. The % CV (coefficient
of variation) values obtained for each analyte were <15%. Additional
biological testing applied the assay to samples collected from healthy
control participants and two groups diagnosed with inflammatory bowel
disease (IBD) (one group treated with the anti-inflammatory 5-aminosalicylic
acid (5-ASA) and one group untreated), with results showing significant
differences in the concentrations of picolinic acid, kynurenine, and
xanthurenic acid. The short analysis time and 96-well plate format
of the assay makes it suitable for high-throughput targeted UHPLC-ESI-MS/MS
metabolomic analysis in large-scale clinical and epidemiological population
studies.
Collapse
|
28
|
Abstract
1. The metabolic fate and urinary excretion of 2-bromophenol, a phenolic metabolite of bromobenzene, was investigated in male Sprague-Dawley rats following single intraperitoneal doses at either 0, 100, or 200 mg/kg.2. Urine was collected for seven days and samples analysed using 1 H NMR spectroscopy, inductively coupled plasma (ICP)MS, and UPLC-MS.3. 1 H NMR spectroscopy of the urine samples showed that, at these doses, 2-bromophenol had little effect on endogenous metabolite profiles, supporting histopathology and clinical chemistry data, which showed no changes associated with the administration of 2-bromophenol in this study.4. The use of ICP-MS provided a means for the selective detection and quantification of bromine-containing species and showed that between 15 and 30% of the dose was excreted via the urine over 7 days of the study for both the 100 and 200 mg doses, respectively.5. The bulk of the excretion of Br-containing material had occurred by 8 h post administration. UPLC-MS of urine revealed a number of metabolites of 2-bromophenol, with 2-bromophenol glucuronide and 2-bromophenol sulphate identified as the major species. A number of minor hydroxylated metabolites were also detected as their glucuronide, sulphate, or O-methyl conjugates. There was no evidence for the production of reactive metabolites.
Collapse
|
29
|
A validated UPLC-MS/MS assay for the quantification of amino acids and biogenic amines in rat urine. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1106-1107:50-57. [DOI: 10.1016/j.jchromb.2018.12.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2018] [Revised: 12/20/2018] [Accepted: 12/27/2018] [Indexed: 02/01/2023]
|
30
|
Development of a rapid profiling method for the analysis of polar analytes in urine using HILIC-MS and ion mobility enabled HILIC-MS. Metabolomics 2019; 15:17. [PMID: 30830424 PMCID: PMC6342856 DOI: 10.1007/s11306-019-1474-9] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 12/20/2018] [Indexed: 12/12/2022]
Abstract
INTRODUCTION As large scale metabolic phenotyping is increasingly employed in preclinical studies and in the investigation of human health and disease the current LC-MS/MS profiling methodologies adopted for large sample sets can result in lengthy analysis times, putting strain on available resources. As a result of these pressures rapid methods of untargeted analysis may have value where large numbers of samples require screening. OBJECTIVES To develop, characterise and evaluate a rapid UHP-HILIC-MS-based method for the analysis of polar metabolites in rat urine and then extend the capabilities of this approach by the addition of IMS to the system. METHODS A rapid untargeted HILIC LC-MS/MS profiling method for the analysis of small polar molecules has been developed. The 3.3 min separation used a Waters BEH amide (1 mm ID) analytical column on a Waters Synapt G2-Si Q-Tof enabled with ion mobility spectrometry (IMS). The methodology, was applied to the metabolic profiling of a series of rodent urine samples from vehicle-treated control rats and animals administered tienilic acid. The same separation was subsequently linked to IMS and MS to evaluate the benefits that IMS might provide for metabolome characterisation. RESULTS The rapid HILIC-MS method was successfully applied to rapid analysis of rat urine and found, based on the data generated from the data acquired for the pooled quality control samples analysed at regular intervals throughout the analysis, to be robust. Peak area and retention times for the compounds detected in these samples showed good reproducibility across the batch. When used to profile the urine samples obtained from vehicle-dosed control and those administered tienilic acid the HILIC-MS method detected 3007 mass/retention time features. Analysis of the same samples using HILIC-IMS-MS enabled the detection of 6711 features. Provisional metabolite identification for a number of compounds was performed using the high collision energy MS/MS information compared against the Metlin MS/MS database and, in addition, both calculated and measured CCS values from an experimentally derived CCS database. CONCLUSION A rapid metabolic profiling method for the analysis of polar metabolites has been developed. The method has the advantages of speed and both reducing sample and solvent consumption compared to conventional profiling methods. The addition of IMS added an additional dimension for feature detection and the identification of metabolites.
Collapse
|
31
|
Capillary ultra performance liquid chromatography-tandem mass spectrometry analysis of tienilic acid metabolites in urine following intravenous administration to the rat. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1087-1088:142-148. [PMID: 29738964 DOI: 10.1016/j.jchromb.2018.04.034] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 03/29/2018] [Accepted: 04/21/2018] [Indexed: 11/17/2022]
Abstract
Capillary scale (100 mm × 150 μm id) UPLC/MS/MS, performed using reversed-phase gradient chromatography on sub 2 μm particles, has been successfully employed for the characterization of the metabolites of the drug tienilic acid (TA) excreted via the urine following oral administration to the rat. The capillary LC system provided a significant increase (range ca. 11-33-fold) in sensitivity compared with a conventional 150 mm × 2.1 mm id UPLC system. An investigation of the effect of the injection volume and sample mass loading on the capillary column on the results obtained for both endogenous metabolites and TA was performed. This demonstrated that the injection of up to 2 μL of rat urine onto the system was permitted whilst still providing excellent chromatographic results and robustness. Qualitative analysis of the urine revealed the presence of TA itself and a total of 15 metabolites of the drug, including those resulting from biotransformations such as hydroxylation or conjugation. The capillary chromatography system was shown to be robust, and capable of providing comprehensive drug metabolite profiles from small format urine samples such as those obtained from preclinical studies in rodents.
Collapse
|
32
|
Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection. Anal Chim Acta 2017; 982:1-8. [PMID: 28734348 PMCID: PMC5533171 DOI: 10.1016/j.aca.2017.06.020] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 06/01/2017] [Accepted: 06/02/2017] [Indexed: 12/21/2022]
Abstract
The need for rapid and efficient high throughput metabolic phenotyping (metabotyping) in metabolomic/metabonomic studies often requires compromises to be made between analytical speed and metabolome coverage. Here the effect of column length (150, 75 and 30 mm) and gradient duration (15, 7.5 and 3 min respectively) on the number of features detected when untargeted metabolic profiling of human urine using reversed-phase gradient ultra performance chromatography with, and without, ion mobility spectrometry, has been examined. As would be expected, reducing column length from 150 to 30 mm, and gradient duration, from 15 to 3 min, resulted in a reduction in peak capacity from 311 to 63 and a similar reduction in the number of features detected from over ca. 16,000 to ca. 6500. Under the same chromatographic conditions employing UPLC/IMS/MS to provide an additional orthogonal separation resulted in an increase in the number of MS features detected to nearly 20,000 and ca. 7500 for the 150 mm and the 30 mm columns respectively. Based on this limited study the potential of LC/IMS/MS as a tool for improving throughput and increasing metabolome coverage clearly merits further in depth study. Ion mobility spectrometry (IMS) significantly increased the number of analytes detected during the LC-MS of urine. Nearly ca. 20,000 features were seen for urine using LC-IMS-MS in a 15 min analysis compared to ca. 16,000 by LC-MS alone. In a 3 min analysis using a 30 mm column nearly 7600 features were detected with combined IMS and MS. For high throughput analysis a 75 mm column and a 3 min analysis was a good compromise between speed and features detected. The use of IMS also improved the quality of the mass spectra obtained.
Collapse
|
33
|
High-Speed Quantitative UPLC-MS Analysis of Multiple Amines in Human Plasma and Serum via Precolumn Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate: Application to Acetaminophen-Induced Liver Failure. Anal Chem 2017; 89:2478-2487. [PMID: 28194962 DOI: 10.1021/acs.analchem.6b04623] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A targeted reversed-phase gradient UPLC-MS/MS assay has been developed for the quantification /monitoring of 66 amino acids and amino-containing compounds in human plasma and serum using precolumn derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQTag Ultra). Derivatization of the target amines required minimal sample preparation and resulted in analytes with excellent chromatographic and mass spectrometric detection properties. The resulting method, which requires only 10 μL of sample, provides the reproducible and robust separation of 66 analytes in 7.5 min, including baseline resolution of isomers such as leucine and isoleucine. The assay has been validated for the quantification of 33 amino compounds (predominantly amino acids) over a concentration range from 2 to 20 and 800 μM. Intra- and interday accuracy of between 0.05 and 15.6 and 0.78-13.7% and precision between 0.91 and 16.9% and 2.12-15.9% were obtained. A further 33 biogenic amines can be monitored in samples for relative changes in concentration rather than quantification. Application of the assay to samples derived from healthy controls and patients suffering from acetaminophen (APAP, paracetamol)-induced acute liver failure (ALF) showed significant differences in the amounts of aromatic and branched chain amino acids between the groups as well as a number of other analytes, including the novel observation of increased concentrations of sarcosine in ALF patients. The properties of the developed assay, including short analysis time, make it suitable for high-throughput targeted UPLC-ESI-MS/MS metabonomic analysis in clinical and epidemiological environments.
Collapse
|
34
|
Development of a Rapid Microbore Metabolic Profiling Ultraperformance Liquid Chromatography-Mass Spectrometry Approach for High-Throughput Phenotyping Studies. Anal Chem 2016; 88:5742-51. [PMID: 27116471 DOI: 10.1021/acs.analchem.6b00038] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
A rapid gradient microbore ultraperformance liquid chromatography-mass spectrometry (UPLC-MS) method has been developed to provide a high-throughput analytical platform for the metabolic phenotyping of urine from large sample cohorts. The rapid microbore metabolic profiling (RAMMP) approach was based on scaling a conventional reversed-phase UPLC-MS method for urinary profiling from 2.1 mm × 100 mm columns to 1 mm × 50 mm columns, increasing the linear velocity of the solvent, and decreasing the gradient time to provide an analysis time of 2.5 min/sample. Comparison showed that conventional UPLC-MS and rapid gradient approaches provided peak capacities of 150 and 50, respectively, with the conventional method detecting approximately 19 000 features compared to the ∼6 000 found using the rapid gradient method. Similar levels of repeatability were seen for both methods. Despite the reduced peak capacity and the reduction in ions detected, the RAMMP method was able to achieve similar levels of group discrimination as conventional UPLC-MS when applied to rat urine samples obtained from investigative studies on the effects of acute 2-bromophenol and chronic acetaminophen administration. When compared to a direct infusion MS method of similar analysis time the RAMMP method provided superior selectivity. The RAMMP approach provides a robust and sensitive method that is well suited to high-throughput metabonomic analysis of complex mixtures such as urine combined with a 5-fold reduction in analysis time compared with the conventional UPLC-MS method.
Collapse
|
35
|
Analysis of polar urinary metabolites for metabolic phenotyping using supercritical fluid chromatography and mass spectrometry. J Chromatogr A 2016; 1449:141-55. [PMID: 27143232 PMCID: PMC4927693 DOI: 10.1016/j.chroma.2016.04.040] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 04/13/2016] [Accepted: 04/14/2016] [Indexed: 10/27/2022]
Abstract
Supercritical fluid chromatography (SFC) is frequently used for the analysis and separation of non-polar metabolites, but remains relatively underutilised for the study of polar molecules, even those which pose difficulties with established reversed-phase (RP) or hydrophilic interaction liquid chromatographic (HILIC) methodologies. Here, we present a fast SFC-MS method for the analysis of medium and high-polarity (-7≤cLogP≤2) compounds, designed for implementation in a high-throughput metabonomics setting. Sixty polar analytes were first screened to identify those most suitable for inclusion in chromatographic test mixtures; then, a multi-dimensional method development study was conducted to determine the optimal choice of stationary phase, modifier additive and temperature for the separation of such analytes using SFC. The test mixtures were separated on a total of twelve different column chemistries at three different temperatures, using CO2-methanol-based mobile phases containing a variety of polar additives. Chromatographic performance was evaluated with a particular emphasis on peak capacity, overall resolution, peak distribution and repeatability. The results suggest that a new generation of stationary phases, specifically designed for improved robustness in mixed CO2-methanol mobile phases, can improve peak shape, peak capacity and resolution for all classes of polar analytes. A significant enhancement in chromatographic performance was observed for these urinary metabolites on the majority of the stationary phases when polar additives such as ammonium salts (formate, acetate and hydroxide) were included in the organic modifier, and the use of water or alkylamine additives was found to be beneficial for specific subsets of polar analytes. The utility of these findings was confirmed by the separation of a mixture of polar metabolites in human urine using an optimised 7min gradient SFC method, where the use of the recommended column and co-solvent combination resulted in a significant improvement in chromatographic performance.
Collapse
|
36
|
High-Throughput Microbore UPLC–MS Metabolic Phenotyping of Urine for Large-Scale Epidemiology Studies. J Proteome Res 2015; 14:2714-21. [DOI: 10.1021/acs.jproteome.5b00203] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
37
|
Tetrahydrobiopterin and alkylglycerol monooxygenase substantially alter the murine macrophage lipidome. Proc Natl Acad Sci U S A 2015; 112:2431-6. [PMID: 25675482 PMCID: PMC4345615 DOI: 10.1073/pnas.1414887112] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Tetrahydrobiopterin is a cofactor synthesized from GTP with well-known roles in enzymatic nitric oxide synthesis and aromatic amino acid hydroxylation. It is used to treat mild forms of phenylketonuria. Less is known about the role of tetrahydrobiopterin in lipid metabolism, although it is essential for irreversible ether lipid cleavage by alkylglycerol monooxygenase. Here we found intracellular alkylglycerol monooxygenase activity to be an important regulator of alkylglycerol metabolism in intact murine RAW264.7 macrophage-like cells. Alkylglycerol monooxygenase was expressed and active also in primary mouse bone marrow-derived monocytes and "alternatively activated" M2 macrophages obtained by interleukin 4 treatment, but almost missing in M1 macrophages obtained by IFN-γ and lipopolysaccharide treatment. The cellular lipidome of RAW264.7 was markedly changed in a parallel way by modulation of alkylglycerol monooxygenase expression and of tetrahydrobiopterin biosynthesis affecting not only various ether lipid species upstream of alkylglycerol monooxygenase but also other more complex lipids including glycosylated ceramides and cardiolipins, which have no direct connection to ether lipid pathways. Alkylglycerol monooxygenase activity manipulation modulated the IFN-γ/lipopolysaccharide-induced expression of inducible nitric oxide synthase, interleukin-1β, and interleukin 1 receptor antagonist but not transforming growth factor β1, suggesting that alkylglycerol monooxygenase activity affects IFN-γ/lipopolysaccharide signaling. Our results demonstrate a central role of tetrahydrobiopterin and alkylglycerol monooxygenase in ether lipid metabolism of murine macrophages and reveal that alteration of alkylglycerol monooxygenase activity has a profound impact on the lipidome also beyond the class of ether lipids.
Collapse
|
38
|
Ion mobility-derived collision cross section as an additional measure for lipid fingerprinting and identification. Anal Chem 2015; 87:1137-44. [PMID: 25495617 PMCID: PMC4302848 DOI: 10.1021/ac503715v] [Citation(s) in RCA: 204] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2014] [Accepted: 12/13/2014] [Indexed: 02/07/2023]
Abstract
Despite recent advances in analytical and computational chemistry, lipid identification remains a significant challenge in lipidomics. Ion-mobility spectrometry provides an accurate measure of the molecules' rotationally averaged collision cross-section (CCS) in the gas phase and is thus related to ionic shape. Here, we investigate the use of CCS as a highly specific molecular descriptor for identifying lipids in biological samples. Using traveling wave ion mobility mass spectrometry (MS), we measured the CCS values of over 200 lipids within multiple chemical classes. CCS values derived from ion mobility were not affected by instrument settings or chromatographic conditions, and they were highly reproducible on instruments located in independent laboratories (interlaboratory RSD < 3% for 98% of molecules). CCS values were used as additional molecular descriptors to identify brain lipids using a variety of traditional lipidomic approaches. The addition of CCS improved the reproducibility of analysis in a liquid chromatography-MS workflow and maximized the separation of isobaric species and the signal-to-noise ratio in direct-MS analyses (e.g., "shotgun" lipidomics and MS imaging). These results indicate that adding CCS to databases and lipidomics workflows increases the specificity and selectivity of analysis, thus improving the confidence in lipid identification compared to traditional analytical approaches. The CCS/accurate-mass database described here is made publicly available.
Collapse
|
39
|
A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS. Analyst 2015; 140:1921-31. [DOI: 10.1039/c4an02090a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This methodology provides increased assay sensitivity and facilitates small volume biofluid analysis in high percent organic samples.
Collapse
|
40
|
An integrated ceramic, micro-fluidic device for the LC/MS/MS analysis of pharmaceuticals in plasma. Analyst 2015; 140:5546-56. [DOI: 10.1039/c5an00646e] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A capillary scale ceramic microfluidic LC/MS/MS system was successfully employed for the analysis of pharmaceutical compounds in plasma.
Collapse
|
41
|
Advances in liquid chromatography coupled to mass spectrometry for metabolic phenotyping. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.06.005] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
42
|
Ultra high resolution SFC–MS as a high throughput platform for metabolic phenotyping: Application to metabolic profiling of rat and dog bile. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 966:200-7. [DOI: 10.1016/j.jchromb.2014.04.017] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 04/03/2014] [Accepted: 04/05/2014] [Indexed: 01/10/2023]
|
43
|
Abstract
Exposure to ionizing radiation has dramatically increased in modern society, raising serious health concerns. The molecular response to ionizing radiation, however, is still not completely understood. Here, we screened mouse serum for metabolic alterations following an acute exposure to γ radiation using a multiplatform mass-spectrometry-based strategy. A global, molecular profiling revealed that mouse serum undergoes a series of significant molecular alterations following radiation exposure. We identified and quantified bioactive metabolites belonging to key biochemical pathways and low-abundance, oxygenated, polyunsaturated fatty acids (PUFAs) in the two groups of animals. Exposure to γ radiation induced a significant increase in the serum levels of ether phosphatidylcholines (PCs) while decreasing the levels of diacyl PCs carrying PUFAs. In exposed mice, levels of pro-inflammatory, oxygenated metabolites of arachidonic acid increased, whereas levels of anti-inflammatory metabolites of omega-3 PUFAs decreased. Our results indicate a specific serum lipidomic biosignature that could be utilized as an indicator of radiation exposure and as novel target for therapeutic intervention. Monitoring such a molecular response to radiation exposure might have implications not only for radiation pathology but also for countermeasures and personalized medicine.
Collapse
|
44
|
Abstract
In the past decade, LC‐MS‐based metabolomic/metabonomic profiling has become a major analytical focus for biomarker research. Chromatographic resolution is continually improving with the development of more advanced separation platforms based on smaller particle sizes, new types of stationary phase and miniaturized systems allowing the profiling of biological samples for metabolites in ways that were simply not possible before. Chromatographic advances, combined with increased mass resolution instruments that provide sub‐2 ppm mass accuracy and high sensitivity, have greatly facilitated the detection and identification of potential biomarkers. In this chapter, the most common LC(‐MS) methods utilized in metabolic analyses are presented, with emphasis on novel high‐efficiency and high‐throughput analyses and their suitability for metabolic analyses. Guidelines for the selection of the appropriate method for different applications are given, with emphasis on the use of LC‐MS.
Collapse
|
45
|
Comparison of reversed-phase and hydrophilic interaction liquid chromatography for the separation of ephedrines. J Chromatogr A 2012; 1228:329-37. [DOI: 10.1016/j.chroma.2011.09.026] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Revised: 09/09/2011] [Accepted: 09/12/2011] [Indexed: 11/26/2022]
|
46
|
Intra- and Interlaboratory Reproducibility of Ultra Performance Liquid Chromatography–Time-of-Flight Mass Spectrometry for Urinary Metabolic Profiling. Anal Chem 2012; 84:2424-32. [DOI: 10.1021/ac203200x] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
47
|
Comprehensive investigation of the influence of acidic, basic, and organic mobile phase compositions on bioanalytical assay sensitivity in positive ESI mode LC/MS/MS. J Pharm Biomed Anal 2012; 59:138-50. [DOI: 10.1016/j.jpba.2011.10.021] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Revised: 10/17/2011] [Accepted: 10/18/2011] [Indexed: 10/15/2022]
|
48
|
Systematic evaluation of acetone and acetonitrile for use in hydrophilic interaction liquid chromatography coupled with electrospray ionization mass spectrometry of basic small molecules. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:3666-3674. [PMID: 22468333 DOI: 10.1002/rcm.5271] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Sub-2-µm particle size hydrophilic interaction liquid chromatography [HILIC] combined with mass spectrometry has been increasing in popularity as a complementary technique to reversed-phase LC for the analysis of polar analytes. The organic-rich mobile phase associated with HILIC techniques provides increases in compound ionization, due to increased desolvation efficiency during electrospray ionisation mass spectrometric (ESI-MS) analysis. Although recent publications illustrated selectivity and response comparisons between reversed-phase LC/MS and HILIC LC/MS, there are limited discussions evaluating the optimisation of the mass spectrometry parameters regarding analytes and alternative mobile phases. The use of acetone as an alternative organic modifier in HILIC has been investigated with respect to signal-to-noise in ESI-MS for a variety of polar analytes. Analyte reponses were measured based on a variety of cone and capillary voltages at low and high pH in both acetone and acetonitrile. In order to visualise compound behaviour in the ESI source, surface plots were constructed to assist in interpreting the observed results. The use of acetone in ESI is complicated at low m/z due to the formation of condensation products. Favourable responses were observed for certain analytes and we envisage offering an insight into the use of acetone as an alternative to acetonitrile under certain analytical conditions for particular compound classifications for small molecule analysis. We also highlight the importance of optimising source voltages in order to obtain the maximum signal stability and sensitivity, which are invariably, highly solvent composition dependent parameters.
Collapse
|
49
|
Rapid detection and identification of counterfeit and [corrected] adulterated products of synthetic phosphodiesterase type-5 inhibitors with an atmospheric solids analysis probe. Drug Test Anal 2011; 2:45-50. [PMID: 20878886 DOI: 10.1002/dta.115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The market success of the three approved synthetic phosphodiesterase type-5 (PDE-5) inhibitors for the treatment of erectile dysfunction has led to an explosion in counterfeit versions of these drugs. In parallel a large market has developed for herbal products claimed to be natural alternatives to these synthetic drugs. The herbal products are heavily advertised on the internet and are freely available to purchase without prescription. Furthermore, adulteration of these supposed natural medicines is a very common and serious phenomenon. Recent reports have shown that the adulteration has extended to the analogues of the three approved synthetic PDE-5 inhibitors. An Atmospheric Solids Analysis Probe (ASAP) was used for the direct analysis of the counterfeit pharmaceuticals and herbal products. Using the ASAP combined with time-of-flight mass spectrometry (TOF MS) it was possible to detect fraudulent counterfeit tablets. The physical appearance of the pills resembled the pills from the original manufacturer but contained the wrong active pharmaceutical ingredient (API). Detecting adulteration for five herbal supplements marketed as natural alternatives to PDE-5 inhibitors was also possible using the ASAP. Three types of adulteration were found in the five samples: adulteration with tadalafil or sildenafil, mixed adulteration (tadalafil and sildenafil), and adulteration with analogues of these drugs.
Collapse
|
50
|
HILIC-UPLC-MS for Exploratory Urinary Metabolic Profiling in Toxicological Studies. Anal Chem 2010; 83:382-90. [DOI: 10.1021/ac102523q] [Citation(s) in RCA: 128] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|