1
|
An International Standard for holotranscobalamin (holoTC): international collaborative study to assign a holoTC value to the International Standard for vitamin B12 and serum folate. Clin Chem Lab Med 2016; 54:1467-72. [PMID: 26863346 DOI: 10.1515/cclm-2015-1167] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 01/11/2016] [Indexed: 11/15/2022]
Abstract
BACKGROUND Investigation of possible B12 and folate deficiencies requires measurement of these vitamins in serum. There is evidence that holotranscobalamin (holoTC), the active portion of B12 available to cells, is a more specific marker of early B12 deficiency than total B12. The availability of immunoassays for holoTC prompted an international collaborative study to assign a holoTC value to the World Health Organization (WHO) 1st International Standard (IS) for vitamin B12 and serum folate, 03/178. METHODS The IS, 03/178, and three serum samples with different holoTC levels were assayed by 12 laboratories in eight countries using manual and automated immunoassays for holoTC; one laboratory additionally performed an in-house assay. Fourteen sets of data were analysed. RESULTS Overall, the IS, 03/178, and the three serum samples demonstrated assay linearity and parallelism. An overall geometric mean (GM) holoTC value of 106.8 pmol/L was obtained for 03/178, with an inter-laboratory geometric coefficient of variation (GCV) of 10.5%. There was a reduction in inter-laboratory variability when the holoTC levels in the serum samples were determined relative to the IS with an assigned holoTC value rather than to the assays' calibration. Accelerated degradation studies showed that 03/178 was sufficiently stable to serve as an IS for holoTC. CONCLUSIONS The WHO Expert Committee on Biological Standardization endorsed the proposal to assign a holoTC value of 107 pmol/L to 03/178, corresponding to 0.107 pmol per ampoule, for use as the 1st IS for vitamin B12, serum folate, and holoTC.
Collapse
|
2
|
Cytokine release assays for the prediction of therapeutic mAb safety in first-in man trials--Whole blood cytokine release assays are poorly predictive for TGN1412 cytokine storm. J Immunol Methods 2015; 424:43-52. [PMID: 25960173 PMCID: PMC4768082 DOI: 10.1016/j.jim.2015.04.020] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 04/29/2015] [Accepted: 04/29/2015] [Indexed: 12/29/2022]
Abstract
The therapeutic monoclonal antibody (mAb) TGN1412 (anti-CD28 superagonist) caused near-fatal cytokine release syndrome (CRS) in all six volunteers during a phase-I clinical trial. Several cytokine release assays (CRAs) with reported predictivity for TGN1412-induced CRS have since been developed for the preclinical safety testing of new therapeutic mAbs. The whole blood (WB) CRA is the most widely used, but its sensitivity for TGN1412-like cytokine release was recently criticized. In a comparative study, using group size required for 90% power with 5% significance as a measure of sensitivity, we found that WB and 10% (v/v) WB CRAs were the least sensitive for TGN1412 as these required the largest group sizes (n = 52 and 79, respectively). In contrast, the peripheral blood mononuclear cell (PBMC) solid phase (SP) CRA was the most sensitive for TGN1412 as it required the smallest group size (n = 4). Similarly, the PBMC SP CRA was more sensitive than the WB CRA for muromonab-CD3 (anti-CD3) which stimulates TGN1412-like cytokine release (n = 4 and 4519, respectively). Conversely, the WB CRA was far more sensitive than the PBMC SP CRA for alemtuzumab (anti-CD52) which stimulates FcγRI-mediated cytokine release (n = 8 and 180, respectively). Investigation of potential factors contributing to the different sensitivities revealed that removal of red blood cells (RBCs) from WB permitted PBMC-like TGN1412 responses in a SP CRA, which in turn could be inhibited by the addition of the RBC membrane protein glycophorin A (GYPA); this observation likely underlies, at least in part, the poor sensitivity of WB CRA for TGN1412. The use of PBMC SP CRA for the detection of TGN1412-like cytokine release is recommended in conjunction with adequately powered group sizes for dependable preclinical safety testing of new therapeutic mAbs.
Collapse
|
3
|
Specifications for anti-A and anti-B in intravenous immunoglobulin: history and rationale. Transfusion 2015; 55 Suppl 2:S80-5. [DOI: 10.1111/trf.13091] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
4
|
The 3rd International Standard for serum IgE: international collaborative study to evaluate a candidate preparation. Clin Chem Lab Med 2015; 52:1283-9. [PMID: 24807170 DOI: 10.1515/cclm-2014-0243] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Accepted: 04/09/2014] [Indexed: 11/15/2022]
Abstract
BACKGROUND The measurement of serum IgE aids in the diagnosis and management of atopic allergic disease and hyper-IgE immunodeficiency syndromes. The 2nd World Health Organization (WHO) International Reference Reagent (IRR) for serum IgE (75/502; 5000 IU/ampoule), is widely used to calibrate assays for serum IgE. Exhaustion of stocks of the 2nd IRR necessitated the production of a replacement preparation and its evaluation in an international collaborative study to determine its suitability to serve as the 3rd International Standard (IS) for serum IgE. METHODS Sera and defibrinated plasma with elevated IgE levels were pooled and lyophilised in ampoules. This preparation, coded 11/234, was assayed by 18 laboratories in 11 countries using commercial assay methodology for IgE, along with the 2nd IRR, 75/502, and two lyophilised serum samples. RESULTS Overall, there were no consistent differences in the way that the candidate IS (11/234), the IRR (75/502), and the two serum samples behaved in the assays with respect to linearity and parallelism. The mean IgE value of the candidate IS, 11/234, relative to the IRR, 75/502, was 13,411 IU/mL based on parallel line analysis of raw assay data at NIBSC, and 13,551 IU/mL based on the laboratories' own estimates after correcting for the values obtained for 75/502. CONCLUSIONS The use of 11/234 will ensure that assays for serum IgE continue to be well standardised. The preparation was established by the WHO Expert Committee on Biological Standardization as the 3rd IS for serum IgE with an assigned value of 13,500 IU/mL, corresponding to 6750 IU/ampoule.
Collapse
|
5
|
An autologous endothelial cell:peripheral blood mononuclear cell assay that detects cytokine storm responses to biologics. FASEB J 2015; 29:2595-602. [PMID: 25746794 DOI: 10.1096/fj.14-268144] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 02/13/2015] [Indexed: 11/11/2022]
Abstract
There is an urgent unmet need for human tissue bioassays to predict cytokine storm responses to biologics. Current bioassays that detect cytokine storm responses in vitro rely on endothelial cells, usually from umbilical veins or cell lines, cocultured with freshly isolated peripheral blood mononuclear cells (PBMCs) from healthy adult volunteers. These assays therefore comprise cells from 2 separate donors and carry the disadvantage of mismatched tissues and lack the advantage of personalized medicine. Current assays also do not fully delineate mild (such as Campath) and severe (such as TGN1412) cytokine storm-inducing drugs. Here, we report a novel bioassay where endothelial cells grown from stem cells in the peripheral blood (blood outgrowth endothelial cells) and PBMCs from the same donor can be used to create an autologous coculture bioassay that responds by releasing a plethora of cytokines to authentic TGN1412 but only modestly to Campath and not to control antibodies such as Herceptin, Avastin, and Arzerra. This assay performed better than the traditional mixed donor assay in terms of cytokine release to TGN1412 and, thus, we suggest provides significant advancement and a definitive system by which biologics can be tested and paves the way for personalized medicine.
Collapse
|
6
|
Severity of the TGN1412 trial disaster cytokine storm correlated with IL-2 release. Br J Clin Pharmacol 2013; 76:299-315. [PMID: 23701319 PMCID: PMC3731604 DOI: 10.1111/bcp.12165] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2012] [Accepted: 04/21/2013] [Indexed: 12/31/2022] Open
Abstract
Aim To determine if cytokine release with a solid phase assay is predictive of adverse responses for a range of therapeutic mAbs. Methods Cytokine ELISAs and a multi-array system were used to compare responses generated by different therapeutic mAbs using a solid phase assay. Flow cytometry was employed to determine the cellular source of those cytokines. Results Only TGN1412 and muromonab-CD3 stimulated CD4+ T-cell mediated cytokine release characterized by significant (all P < 0.0001) IFNγ, TNFα, IL-2, IL-4, IL-5, IL-10, IL-12, IL-13, IL-17 and IL-22 release, comparable with T-cell mitogen. Significantly greater (P < 0.0001) IL-2 release with TGN1412 (2894–6051 pg ml−1) compared with muromonab-CD3 (62–262 pg ml−1) differentiated otherwise comparable cytokine responses. Likewise, TGN1412 stimulated significantly more (P = 0.0001) IL-2 producing CD4+ T-cells than muromonab-CD3 and induced Th1, Th2, Th17 and Th22 subsets that co-release this cytokine. Significant TNFα release was observed with bevacizumab (P = 0.0001), trastuzumab (P = 0.0031) and alemtuzumab (P = 0.0177), but no significant IL-2 release. TGN1412 and muromonab-CD3 caused pro-inflammatory cytokine release despite significantly (both P < 0.0001) increasing numbers of T-cells with a regulatory phenotype. Conclusions The severity of the adverse response to TGN1412 compared with muromonab-CD3 and other therapeutic mAbs correlates with the level of IL-2 release.
Collapse
|
7
|
Intravenous immunoglobulin-induced haemolysis: a case report and review of the literature. Transfus Med 2013; 24:219-26. [PMID: 24164446 DOI: 10.1111/tme.12083] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2013] [Revised: 08/19/2013] [Accepted: 09/25/2013] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To review the incidence and clinical features of intravenous immunoglobulin (IVIg)-induced haemolysis. BACKGROUND Haemolysis can be a severe complication of IVIg administration. It is due to the passive transfer of blood group antibodies and may result in significant anaemia and renal failure. METHODS We report a case of severe IVIg-induced haemolysis; review the data reported to vigilance groups (The Medicines and Healthcare Products Regulatory Agency, European Union Drug Regulatory Authorities, Food and Drug Administration and the Canada Vigilance Centre) between January 1998 and May 2012; and systematically review IVIg-induced haemolysis case reports (between January 1948 and January 2013). RESULTS Nine hundred-twenty five cases of IVIg-induced haemolysis were identified from a review of cases reported to vigilance groups; 62 case reports were included in the systematic review. The majority of these were due to administration of doses of at least 2 g kg(-1) of IVIg (97%). IVIg-induced haemolysis was reported most commonly for patients with blood group A (65%) or AB (26%). One case report noted that in two patients with IVIg-induced haemolysis both received IVIg from the same batch. CONCLUSION We make the following recommendations for the management of suspected cases of IVIg-induced haemolysis: Stop IVIg infusion and perform tests for haemolysis. Check titres of anti-blood group antibodies in IVIg. Provide supportive management for patient with fluid and/or red blood cell transfusions if necessary. Consider quarantine of the IVIg batch if found to be high titre for anti-A/B. Report reaction to regulatory/vigilance body.
Collapse
|
8
|
Antibody C Region Influences TGN1412-like Functional Activity In Vitro. THE JOURNAL OF IMMUNOLOGY 2012; 189:5831-40. [DOI: 10.4049/jimmunol.1201795] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
9
|
Endothelial cells co-stimulate peripheral blood mononuclear cell responses to monoclonal antibody TGN1412 in culture. Cytokine 2011; 55:141-51. [DOI: 10.1016/j.cyto.2011.03.019] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Accepted: 03/18/2011] [Indexed: 12/01/2022]
|
10
|
Abstract
A roundtable to discuss the measurement of folate status biomarkers in NHANES took place in July 2010. NHANES has measured serum folate since 1974 and red blood cell (RBC) folate since 1978 with the use of several different measurement procedures. Data on serum 5-methyltetrahydrofolate (5MTHF) and folic acid (FA) concentrations in persons aged ≥60 y are available in NHANES 1999-2002. The roundtable reviewed data that showed that folate concentrations from the Bio-Rad Quantaphase II procedure (Bio-Rad Laboratories, Hercules, CA; used in NHANES 1991-1994 and NHANES 1999-2006) were, on average, 29% lower for serum and 45% lower for RBC than were those from the microbiological assay (MA), which was used in NHANES 2007-2010. Roundtable experts agreed that these differences required a data adjustment for time-trend analyses. The roundtable reviewed the possible use of an isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) measurement procedure for future NHANES and agreed that the close agreement between the MA and LC-MS/MS results for serum folate supported conversion to the LC-MS/MS procedure. However, for RBC folate, the MA gave 25% higher concentrations than did the LC-MS/MS procedure. The roundtable agreed that the use of the LC-MS/MS procedure to measure RBC folate is premature at this time. The roundtable reviewed the reference materials available or under development at the National Institute of Standards and Technology and recognized the challenges related to, and the scientific need for, these materials. They noted the need for a commutability study for the available reference materials for serum 5MTHF and FA.
Collapse
|
11
|
Abstract
A roundtable to discuss the measurement of vitamin B-12 (cobalamin) status biomarkers in NHANES took place in July 2010. NHANES stopped measuring vitamin B-12-related biomarkers after 2006. The roundtable reviewed 3 biomarkers of vitamin B-12 status used in past NHANES--serum vitamin B-12, methylmalonic acid (MMA), and total homocysteine (tHcy)--and discussed the potential utility of measuring holotranscobalamin (holoTC) for future NHANES. The roundtable focused on public health considerations and the quality of the measurement procedures and reference methods and materials that past NHANES used or that are available for future NHANES. Roundtable members supported reinstating vitamin B-12 status measures in NHANES. They noted evolving concerns and uncertainties regarding whether subclinical (mild, asymptomatic) vitamin B-12 deficiency is a public health concern. They identified the need for evidence from clinical trials to address causal relations between subclinical vitamin B-12 deficiency and adverse health outcomes as well as appropriate cutoffs for interpreting vitamin B-12-related biomarkers. They agreed that problems with sensitivity and specificity of individual biomarkers underscore the need for including at least one biomarker of circulating vitamin B-12 (serum vitamin B-12 or holoTC) and one functional biomarker (MMA or tHcy) in NHANES. The inclusion of both serum vitamin B-12 and plasma MMA, which have been associated with cognitive dysfunction and anemia in NHANES and in other population-based studies, was preferable to provide continuity with past NHANES. Reliable measurement procedures are available, and National Institute of Standards and Technology reference materials are available or in development for serum vitamin B-12 and MMA.
Collapse
|
12
|
Consistent manufacturing and quality control of a highly complex recombinant polyclonal antibody product for human therapeutic use. Biotechnol Bioeng 2011; 108:2171-81. [PMID: 21495017 DOI: 10.1002/bit.23166] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 03/28/2011] [Accepted: 03/30/2011] [Indexed: 01/31/2023]
Abstract
The beneficial effect of antibody therapy in human disease has become well established mainly for the treatment of cancer and immunological disorders. The inherent monospecificity of mAbs present limitations to mAb therapy which have become apparent notably in addressing complex entities like infectious agents or heterogenic endogenous targets. For such indications mixtures of antibodies comprising a combination of specificities would convey more potent biological effect which could translate into therapeutic efficacy. Recombinant polyclonal antibodies (rpAb) consisting of a defined number of well-characterized mAbs constitute a new class of target specific antibody therapy. We have developed a cost-efficient cell banking and single-batch manufacturing concept for the production of such products and demonstrate that a complex pAb composition, rozrolimupab, comprising 25 individual antibodies can be manufactured in a highly consistent manner in a scaled-up manufacturing process. We present a strategy for the release and characterization of antibody mixtures which constitute a complete series of chemistry, manufacturing, and control (CMC) analytical methods to address identity, purity, quantity, potency, and general characteristics. Finally we document selected quality attributes of rozrolimupab based on a battery of assays at the genetic-, protein-, and functional level and demonstrate that the manufactured rozrolimupab batches are highly pure and very uniform in their composition.
Collapse
|
13
|
Release of proteolytic activity following reduction in therapeutic human serum albumin containing products: detection with a new neoepitope endopeptidase immunoassay. J Pharm Biomed Anal 2010; 54:74-80. [PMID: 20832960 DOI: 10.1016/j.jpba.2010.08.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2010] [Revised: 08/04/2010] [Accepted: 08/09/2010] [Indexed: 10/19/2022]
Abstract
Botulinum type A toxin (BoNT/A) is defined by its specific endopeptidase cleavage of SNAP25 between Gln(197) and Arg(198) under reducing conditions. The neurotoxin is widely used for therapeutic or cosmetic purposes, but should not contain other toxin serotypes or unwanted protease activities. Using a neoepitope endopeptidase immunoassay, additional cleavage between Arg(198) and Ala(199) was detected with a range of therapeutic BoNT/A products confirming an earlier report of an unidentified proteolytic component. By developing the assay and making it insensitive to BoNT/C1, any activity due to the type C1 toxin was excluded. Therapeutic preparations consist of ng quantities of toxin protein which are typically stabilised by 0.125-30 mg of HSA. An excellent correlation (R(2)=0.993) between HSA content per vial and measured activity was obtained within the therapeutic BoNT/A products tested. No activity was detected in any of the non-albumin formulated preparations, thereby identifying HSA as the source of the unknown protease for the first time. To investigate the cause of this activity, either as an intrinsic molecular activity of albumin or due to an albumin-associated purification contaminant, further studies on a variety of commercial plasma-derived HSA products or recombinant HSA materials free from potential plasma contaminants were carried out. The measured proteolytic levels were highly consistent amongst preparations, and could all be partially inhibited by the presence of zinc and blocked by PKSI-527 and aprotinin. By contrast, the data did not support the role of plasmin, kallikrein, trypsin, α(2)-antiplasmin-plasmin complexes or HSA purification contaminants, PKA (prekallikrein activator) or kallikrein-like activity. Taken together, these findings indicate a new intrinsic proteolytic activity of the albumin molecule revealed under reducing conditions as the source of the unexpected Arg-Ala cleaving activity.
Collapse
|
14
|
The development and role of international biological reference materials in the diagnosis of anaemia. Biologicals 2010; 38:449-58. [DOI: 10.1016/j.biologicals.2010.02.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2010] [Accepted: 02/05/2010] [Indexed: 10/19/2022] Open
|
15
|
International collaborative study to establish reference preparations to standardise haemagglutination testing for anti-A and anti-B in normal intravenous immunoglobulins by the direct method. PHARMEUROPA BIO & SCIENTIFIC NOTES 2010; 2010:39-50. [PMID: 20223189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A joint project (coded BSP089) was run by the European Directorate for the Quality of Medicines & HealthCare (EDQM) of the Council of Europe, the National Institute for Biological Standards and Control (NIBSC) on behalf of the World Health Organization (WHO) and the Center for Biologics Evaluation and Research (CBER) of the U.S. Food and Drug Administration (FDA) to evaluate, in an international collaborative study, 3 lyophilised intravenous immunoglobulin (IVIG) preparations for their suitability to serve as Reference Preparations to standardise and control the highly variable haemagglutination testing for anti-A and anti-B in IVIG products. 23 laboratories tested candidate IVIG reference preparations consisting of a Positive control, a Negative control and a specifically formulated Limit test reference preparation to define the maximum (e.g., pharmacopoeial) limits of anti-A and anti-B haemagglutinins in IVIG products, where limits are applicable. Laboratories performed direct haemagglutination using papain-treated erythrocytes and/or indirect anti-globulin tests. For both methods, there was up to 16-fold variation in anti-A and anti-B titres, although there was good agreement over a 2-fold titre range for anti-A and anti-B between laboratories using the direct method for both the Positive control and Limit reference preparations. Comparative titration data for the Positive control and Limit reference preparations indicated that the use of a 'Limit' test reference preparation would facilitate identification of higher titre batches when the direct haemagglutination method is used. The Positive control, Negative control and Limit test preparations were adopted in November 2008 by the Commission of the European Pharmacopoeia (Ph. Eur.) as Biological Reference Preparations. The same preparations have been established as reference reagents by the WHO and the U.S FDA, including the maximal specifications defined by the Limit test preparation. This will facilitate global standardisation of haemagglutination tests for anti-A and anti-B, ensure that such tests are sufficiently sensitive and specific, and facilitate identification of batches that exceed maximum recommended levels of anti-A and anti-B antibodies.
Collapse
|
16
|
A WHO Reference Reagent for the Serum Transferrin Receptor (sTfR): international collaborative study to evaluate a recombinant soluble transferrin receptor preparation. Clin Chem Lab Med 2010; 48:815-20. [DOI: 10.1515/cclm.2010.167] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
17
|
Therapeutic IgG4 antibodies engage in Fab-arm exchange with endogenous human IgG4 in vivo. Nat Biotechnol 2009; 27:767-71. [PMID: 19620983 DOI: 10.1038/nbt.1553] [Citation(s) in RCA: 219] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2009] [Accepted: 06/25/2009] [Indexed: 11/09/2022]
Abstract
Two humanized IgG4 antibodies, natalizumab and gemtuzumab, are approved for human use, and several others, like TGN1412, are or have been in clinical development. Although IgG4 antibodies can dynamically exchange half-molecules, Fab-arm exchange with therapeutic antibodies has not been demonstrated in humans. Here, we show that natalizumab exchanges Fab arms with endogenous human IgG4 in natalizumab-treated individuals. Gemtuzumab, in contrast, contains an IgG4 core-hinge mutation that blocks Fab-arm exchange to undetectable levels both in vitro and in a mouse model. The ability of IgG4 therapeutics to recombine with endogenous IgG4 may affect their pharmacokinetics and pharmacodynamics. Although pharmacokinetic modeling lessens concerns about undesired cross-linking under normal conditions, unpredictability remains and mutations that completely prevent Fab-arm exchange in vivo should be considered when designing therapeutic IgG4 antibodies.
Collapse
|
18
|
"Perhaps you only imagined doing it": reality-monitoring in obsessive-compulsive checkers using semi-idiographic stimuli. J Behav Ther Exp Psychiatry 2008; 39:305-20. [PMID: 17884012 DOI: 10.1016/j.jbtep.2007.08.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/01/2007] [Indexed: 12/28/2022]
Abstract
Memory failures reported by obsessive-compulsive (OC) checkers often seem to be errors of "reality-monitoring", or misremembering whether one performed or imagined performing an action. To examine these memory processes in the context in which such errors are said to occur, an in-home reality-monitoring experiment involving bothersome and non-bothersome actions was conducted with 21 OC checkers and 24 non-clinical controls. OC checkers reported poorer confidence in memory, but both groups performed similarly on tests of immediate and delayed free and prompted recall. Among OC checkers (but not controls), accuracy in recall and confidence in memory were correlated. Theoretical implications are discussed.
Collapse
|
19
|
A new approach for the antenatal diagnosis of β-thalassaemia: a double labelling immunofluorescence microscopy technique. Br J Haematol 2008. [DOI: 10.1111/j.1365-2141.1983.00001.x-i1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Abstract
Two monoclonal antibodies to human ferritin, including one that was coupled to horseradish peroxidase, were lyophilized. These reagents show little loss of activity on reconstitution and demonstrate acceptable stability in the accelerated degradation test. When applied in a simple ELISA for the assay of serum ferritin along with the WHO standard for serum ferritin (80/602) they provide a robust assay with standardized reagents which is potentially suitable for use as a reference assay.
Collapse
|
21
|
Anti-D and anti-i activities are inseparable in V4-34-encoded monoclonal anti-D: the same framework 1 residues are required for both reactivities. Transfusion 2008. [DOI: 10.1111/j.1537-2995.2007.01624.x-i2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
22
|
Anti-D and anti-i activities are inseparable in V4-34-encoded monoclonal anti-D: the same framework 1 residues are required for both reactivities. Transfusion 2008; 48:930-40. [PMID: 18346025 DOI: 10.1111/j.1537-2995.2007.01624.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND The heavy-chain V4-34 germline gene segment is mandatory for pathologic cold-reacting autoantibodies with anti-I/i specificity (cold agglutinins) and is also preferentially used by monoclonal immunoglobulin M alloantibodies against D and other Rh antigens. The use of the V4-34 segment by monoclonal anti-D has previously been shown to also confer anti-I/i reactivity (cold agglutinin activity), which has implications for the use of such antibodies for Rh blood typing. V4-34 framework 1 (FR1) sequence is believed to be critical for cold agglutinin activity of cold agglutinins. STUDY DESIGN AND METHODS The aim of this investigation was to use site-directed mutagenesis of a recombinant V4-34-encoded anti-D to determine the contribution of V4-34 FR1 sequence to anti-D activity and whether mutational modifications in the FR1 region could separately alter anti-D and anti-i activities. RESULTS The results show that amino acid changes in V4-34 FR1 at W7, A23, and Y25 have a profound effect on anti-D activity as well as on anti-i activity. It was not possible to substantially reduce or remove anti-i activity without reducing anti-D activity to a comparable extent. CONCLUSIONS The same nonpolar hydrophobic amino acids in FR1 are critical for maintaining both anti-D and anti-i activity. It is proposed that these residues influence the conformation of the antigen-binding site.
Collapse
|
23
|
“Cytokine Storm” in the Phase I Trial of Monoclonal Antibody TGN1412: Better Understanding the Causes to Improve PreClinical Testing of Immunotherapeutics. THE JOURNAL OF IMMUNOLOGY 2007; 179:3325-31. [PMID: 17709549 DOI: 10.4049/jimmunol.179.5.3325] [Citation(s) in RCA: 214] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The CD28-specific mAb TGN1412 rapidly caused a life-threatening "cytokine storm" in all six healthy volunteers in the Phase I clinical trial of this superagonist, signaling a failure of preclinical safety testing. We report novel in vitro procedures in which TGN1412, immobilized in various ways, is presented to human white blood cells in a manner that stimulates the striking release of cytokines and profound lymphocyte proliferation that occurred in vivo in humans. The novel procedures would have predicted the toxicity of this superagonist and are now being applied to emerging immunotherapeutics and to other therapeutics that have the potential to act upon the immune system. Data from these novel procedures, along with data from in vitro and in vivo studies in nonhuman primates, suggest that the dose of TGN1412 given to human volunteers was close to the maximum immunostimulatory dose and that TGN1412 is not a superagonist in nonhuman primates.
Collapse
|
24
|
Abstract
It has been suggested that VH4-34 gene segment expression is counter-selected in multiple myeloma (MM) due to a self-tolerance mechanism. We cloned and sequenced a VH4-34 gene segment from bone marrow mononuclear cells of a stage III MM patient. We show that VH4-34 was expressed by the serum IgA myeloma (M)-protein, as demonstrated by reactivity with the VH4-34 specific 9G4 mAb and mass spectrometry (MS). The M-protein had weak reactivity with nuclei. These results demonstrate that VH4-34 may be expressed in secreted IgA M-protein with weak autoreactivity. Thus, counter-selection of VH4-34 is pronounced but not absolute in MM. Mechanisms of how VH4-34 can occasionally be expressed in MM and clinical implications are discussed.
Collapse
|
25
|
International Standard for serum vitamin B12 and serum folate: international collaborative study to evaluate a batch of lyophilised serum for B12 and folate content. Clin Chem Lab Med 2007; 45:380-6. [PMID: 17378737 DOI: 10.1515/cclm.2007.072] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Vitamin B(12) and folate measurements in serum show wide inter-methodology variability. This variability appears to be due in part to the lack of standardisation against internationally accepted reference materials. Pooled human serum, lyophilised in ampoules and designated 03/178, was therefore evaluated by 24 laboratories in seven countries for its suitability to serve as an International Standard (IS) for B(12) and folate. METHODS IS 03/178 was assayed using a range of commercial analysers, microbiological assays and, for folate, candidate reference methods based on liquid chromatography coupled to isotope-dilution tandem mass spectrometry (LC/MS/MS). RESULTS Mean vitamin B(12) and folate values for reconstituted 03/178 across all laboratories and methods were 480 pg/mL [coefficient of variation (CV) 12.8%] and 5.52 ng/mL (CV 17.1%), respectively. The total folate content of reconstituted 03/178, determined using LC/MS/MS, was 12.1 nmol/L (equivalent to 5.33 ng/mL), made up of 9.75 nmol/L 5-methyl tetrahydrofolic acid (5MeTHF; CV 5.5%), 1.59 nmol/L 5-formyl tetrahydrofolic acid (5FoTHF; CV 4.2%) and 0.74 nmol/L folic acid (FA; CV 31.6%). The inclusion of three serum samples in the study with different B(12) and folate levels demonstrated a considerable reduction in inter-laboratory variability when the B(12) and folate content of the samples was determined relative to the IS 03/178 rather than to the analyser calibration. IS 03/178 demonstrated satisfactory long-term stability in accelerated degradation studies. CONCLUSIONS Use of IS 03/178 to standardise serum B(12) and folate assays reduced inter-laboratory variability. The World Health Organization (WHO) Expert Committee on Biological Standardisation established 03/178 as the first IS for serum vitamin B(12) and serum folate, with assigned values of 480 pg/mL of vitamin B(12) and 12.1 nmol/L folate when the lyophilised contents of the ampoule are reconstituted with 1 mL of water.
Collapse
|
26
|
International standards for minimum potency of anti-A and anti-B blood grouping reagents: evaluation of candidate preparations in an international collaborative study. Vox Sang 2006; 91:336-44. [PMID: 17105610 DOI: 10.1111/j.1423-0410.2006.00834.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of the study was to evaluate lyophilized monoclonal IgM anti-A and anti-B preparations for use as international standards (IS) to specify recommended minimum potencies of anti-A and anti-B blood grouping reagents in tube tests. MATERIALS AND METHODS The candidate IS for minimum potency of anti-A and anti-B blood grouping reagents, codes 03/188 and 03/164, respectively, were evaluated against a wide range of commercial anti-A and anti-B blood grouping reagents in an international collaborative study involving 16 laboratories in nine countries. Laboratories titrated 03/188 and 03/164 in parallel with as many commercial anti-A and anti-B blood grouping reagents, respectively, as were available to them, in tube tests according to specified haemagglutination methodology. Three of these laboratories and a further laboratory also titrated 03/188 and 03/164 in parallel with currently available reference preparations for anti-A and anti-B. The ratios of the mean endpoint titres of the anti-A and anti-B reagents to those of 03/188 and 03/164, respectively, within each laboratory were calculated. RESULTS The ratios of the mean titres of the anti-A reagents to the mean titre of 03/188 within a laboratory fell within 0.062 and 4, i.e. the potencies of the anti-A reagents were between a sixteenth to four times as strong as 03/188. The ratios of the mean titres of the anti-B reagents to the mean titre of 03/164 within a laboratory also fell within 0.062 and 4, with one outlier. CONCLUSIONS By international consensus, a 1 in 8 dilution of the candidate IS for anti-A, 03/188, and a 1 in 4 dilution of the candidate IS for anti-B, 03/164, were considered appropriate to define the recommended minimum potencies of anti-A and anti-B blood grouping reagents, respectively, in tube tests. On the basis of these results, preparations 03/188 and 03/164 were established by the World Health Organization as International Standards for Minimum Potency of Anti-A and Anti-B Blood Grouping Reagents respectively, and by the US Food and Drug Administration Center for Biologics Evaluation and Research as Minimum Potency Reference Reagents.
Collapse
|
27
|
International collaborative study to establish immunoglobulin (anti-D test) BRP batch 1. PHARMEUROPA BIO 2006; 2006:49-56. [PMID: 17270131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
An international collaborative study was organised to establish a European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) and United States (US) Food and Drug Administration (FDA) reference preparation for the test for anti-D (anti-Rho) antibodies in human normal immunoglobulin for intravenous administration (IGIV). A candidate positive control (IGIV+anti-D) and negative control IGIV were compared to corresponding World Health Organization (WHO) International Reference Reagents using a direct haemagglutination reference method. Sixteen (16) laboratories participated in the collaborative study. Further to completion of the study, the materials assayed in the study were granted the status of Ph. Eur. and US FDA reference preparations for controlling the levels of anti-D in IGIV.
Collapse
|
28
|
International collaborative study to assess candidate reference preparations to control the level of anti-D in IVIG for use in Europe and the United States. Biologicals 2006; 34:209-12. [PMID: 16492398 DOI: 10.1016/j.biologicals.2005.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2005] [Accepted: 11/04/2005] [Indexed: 11/20/2022] Open
Abstract
Regulatory requirements to control the level of anti-D in intravenous immunoglobulin (IVIG) products with European and United States (US) licences are to be introduced. A reference preparation of IVIG containing anti-D at 0.0475 IU/ml and having a nominal titre of 8 using the proposed direct haemagglutination reference method was deemed suitable to define the anti-D limit. This preparation, code 02/228, and a negative control IVIG preparation, code 02/226, were established by the World Health Organization as International Reference Reagents (IRRs). As stocks of the IRRs are limited, new larger fill stocks of positive and negative reference preparations, codes 04/132 and 04/140, respectively, were produced. The results from an international collaborative study involving 16 laboratories showed that preparations 04/132 and 04/140 are indistinguishable from the corresponding IRRs 02/228 and 02/226, respectively, using the proposed direct haemagglutination reference method. Stocks of 04/132 and 04/140 have been shared with the European Directorate for the Quality of Medicines (re-coded as 23613 and 23614, respectively) and with the Center for Biologics Evaluation and Research of the United States Food and Drug Administration (re-coded as CBER Lots 1B and 1N-b, respectively) for use as European and US Biological Reference Preparations, respectively.
Collapse
|
29
|
An International Standard for specifying the minimum potency of anti-D blood-grouping reagents: evaluation of a candidate preparation in an international collaborative study. Vox Sang 2006; 90:131-9. [PMID: 16430672 DOI: 10.1111/j.1423-0410.2005.00735.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of this study was to evaluate a lyophilized monoclonal immunoglobulin M (IgM) anti-D preparation for use as an International Standard to specify a recommended minimum acceptable potency of anti-D blood-grouping reagents. MATERIALS AND METHODS The candidate International Standard (99/836) for specifying the minimum potency of anti-D blood-grouping reagents was evaluated against a wide range of commercial anti-D blood-grouping reagents in an international collaborative study involving 20 laboratories in 13 countries. Laboratories titrated reconstituted 99/836, in parallel with as many commercial anti-D blood-grouping reagents as were available to them, in tube tests according to specified haemagglutination methodology for low-protein (e.g. monoclonal IgM) and high-protein (e.g. polyclonal) reagents. The ratios of the mean end-point titres of the reagents to that of 99/836 within each laboratory were calculated. RESULTS The ratios of the mean titres of the low-protein reagents to the mean titre of 99/836 within a laboratory fell between 0.25 and 2 for 43 of the 45 low-protein anti-D reagents tested (i.e. the potencies of the low-protein reagents compared with 99/836 were between a 1:4 dilution of 99/836 to twice as potent as 99/836). The ratios of the mean titres of the high-protein reagents to the mean titre of 99/836 within a laboratory fell within 0.125 and 1 for eight out of the 10 high protein reagents tested. CONCLUSIONS By international consensus, a 1:3 dilution of reconstituted 99/836 was deemed appropriate to define a recommended minimum acceptable potency of low-protein anti-D blood-grouping reagents. A 1:8 dilution of reconstituted 99/836 was deemed appropriate to define a recommended minimum acceptable potency of high-protein anti-D blood-grouping reagents. On the basis of the results presented here, 99/836 was established by the World Health Organization as the 1st International Standard for specifying the minimum potency of anti-D blood-grouping reagents, in tube tests.
Collapse
|
30
|
Anti-A and anti-B activity in batches of different intravenous immunoglobulin products determined using a direct haemagglutination method. Biologicals 2005; 33:111-6. [PMID: 15905100 DOI: 10.1016/j.biologicals.2005.02.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2004] [Revised: 11/11/2004] [Accepted: 02/28/2005] [Indexed: 11/24/2022] Open
Abstract
The European Pharmacopoeia requires that manufacturers assess intravenous immunoglobulin (IVIG) products for antibodies against blood groups A and B using an indirect anti-globulin test (AGT). However, this method suffers from the disadvantage that the anti-globulin reagent may be neutralised by excess IgG and invalidate the data generated. In view of this, we have used a direct microtitre-based haemagglutination method to screen batches of IVIG products from five manufacturers for anti-A and anti-B, and compared the titres with those reported by the manufacturers. The range of reported titres varied 32-fold across the different products, whereas virtually all the direct method titres fell within a 4-fold range for each specificity. This indicated that the discrepancies in reported titres were due to inconsistencies in manufacturers' testing methodology and/or interpretation of results. Our finding that the anti-globulin reagent used to bring about agglutination of anti-A- or anti-B-sensitised erythrocytes in the AGT was neutralised by excess IgG at least down to a 1 in 8 dilution of IVIG (from 5% (w/v) IgG) casts serious doubts on the suitability of the AGT for testing high immunoglobulin concentration products.
Collapse
|
31
|
International collaborative study to evaluate a candidate reference preparation to define an appropriate specified limit of anti-D in intravenous immunoglobulin products. Vox Sang 2005; 88:278-87. [PMID: 15877651 DOI: 10.1111/j.1423-0410.2005.00622.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of the study was to evaluate a lyophilized intravenous immunoglobulin (IVIG) preparation containing anti-D (02/228; nominal reciprocal titre of 8) for its suitability to define the maximum limit of anti-D in IVIG products when used in a proposed reference method of direct haemagglutination of papain-treated erythrocytes, in an international collaborative study. MATERIALS AND METHODS Twenty laboratories tested 02/228 along with a negative control IVIG preparation and four IVIG samples containing different levels of anti-D. Nineteen laboratories performed direct haemagglutination methodology using papain-treated erythrocytes; five of these laboratories and one additional laboratory performed their in-house haemagglutination methodology (all indirect antiglobulin tests). RESULTS The mode titre of 02/228, obtained by using the proposed reference method, was 8 (62.5% of tests). However, there was wide variation in haemagglutination titres between laboratories for three of the four samples. Correcting the titres of the samples relative to those of the proposed reference preparation reduced the interlaboratory variability and increased the frequency of the mode titres in three out of four samples. The indirect antiglobulin tests also showed wide interlaboratory variability and were less sensitive than the direct method in four laboratories. Eleven of the 14 laboratories that expressed an opinion considered that the level of anti-D in 02/228 was appropriate to define a specified limit. CONCLUSIONS Our results demonstrate the necessity of using a reference preparation to define the maximum level of anti-D in IVIG products and ensure sufficient sensitivity in haemagglutination testing methodology. On the basis of these results, members of the European Pharmacopoeia Expert Group 6B recommended revision of the appropriate monograph to include this new specification and test. The Food and Drug Administration in the USA intends to adopt the same maximal specification defined by the reference preparation and to recommend the same test for the safety of IVIG products. Preparations 02/228 and 02/226 were also established by the World Health Organization as International Reference Reagents to standardize haemagglutination testing for anti-D in normal IVIG products.
Collapse
|
32
|
A calpain-like proteolytic activity produces the limited cleavage at the N-terminal regulatory domain of rabbit skeletal muscle AMP deaminase: evidence of a protective molecular mechanism. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2004; 1702:191-8. [PMID: 15488771 DOI: 10.1016/j.bbapap.2004.08.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2004] [Revised: 08/23/2004] [Accepted: 08/25/2004] [Indexed: 11/19/2022]
Abstract
On storage at 4 degrees C, rabbit skeletal muscle AMP deaminase undergoes limited proteolysis with the conversion of the native 85-kDa enzyme subunit to a 75-kDa core that is resistant to further proteolysis. Further studies have shown that limited proteolysis of AMP deaminase with trypsin, removing the 95-residue N-terminal fragment, converts the native enzyme to a species that exhibits hyperbolic kinetics even at low K+ concentration. The results of this report show that a 21-residue synthetic peptide, when incubated with the purified enzyme, is cleaved with a specificity identical to that reported for ubiquitous calpains. In addition, the cleavage of a specific fluorogenic peptide substrate by rabbit m-calpain is inhibited by a synthetic peptide that corresponds to residues 10-17 of rabbit skeletal muscle AMP deaminase; this peptide contains a sequence (K-E-L-D-D-A) that is present in the fourth subdomain A of rabbit calpastatin, suggesting that the N-terminus of AMP deaminase shares with calpastatin a regulatory sequence that might exert a protective role against the fragmentation-induced activation of AMP deaminase. These observations suggest that a calpain-like proteinase present in muscle removes from AMP deaminase a domain that holds the enzyme in an inactive conformation and which also contains a regulatory region that protects against unregulated proteolysis. We conclude that proteolysis of AMP deaminase is the basis of the large ammonia accumulation that occurs in skeletal muscle subjected to strong tetanic contraction or passing into rigor mortis.
Collapse
|
33
|
Factors involved in the formation of attitudes towards those who are mentally ill. Soc Psychiatry Psychiatr Epidemiol 2004; 39:228-34. [PMID: 14999456 DOI: 10.1007/s00127-004-0723-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/15/2003] [Indexed: 10/26/2022]
Abstract
BACKGROUND This research was conducted to examine the prediction that accuracy of particular kinds of knowledge of mental illness would be related to particular attitudes towards people with mental illness. METHODS An exploratory study examining attitudes to people suffering from mental illness is presented. A total of 169 participants, with a range of attitudes and knowledge, completed two questionnaires: attitudes were assessed using the Community Attitudes towards the Mentally Ill scale (Taylor and Dear 1981) which yields four attitude factors; knowledge was assessed using a questionnaire devised by Nunnally (1961), which yields ten knowledge factors. RESULTS Multiple regression analyses provided some support for the hypothesis that some areas of knowledge (particularly knowledge concerning guidance and support, and knowledge concerning the role of avoidance of morbid thoughts in mental health) are predictive of specific attitudes, but much of the variance remained unexplained by the predictive knowledge variables. Post hoc analyses revealed that those people who had had personal experience of people with mental illness were generally more positive in their attitudes towards them. CONCLUSIONS Selected knowledge factors only accounted for a modest amount of the variance in attitude factor scores. Affective (e. g. fear, revulsion, anxiety) information may explain a greater percentage of variance in attitude factor score. It is suggested that this should be considered in future research and the limitations of the present study are discussed.
Collapse
|
34
|
An International Standard for whole blood folate: evaluation of a lyophilised haemolysate in an international collaborative study. ACTA ACUST UNITED AC 2004; 42:533-9. [PMID: 15202790 DOI: 10.1515/cclm.2004.090] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractFolate measurements, particularly for whole blood, show wide inter-laboratory and inter-methodology variability. This variability appears to be due in part to the lack of internationally accepted reference materials. A whole blood haemolysate, lyophilised in ampoules and designated 95/528, was therefore evaluated by 15 laboratories in five countries for its suitability as an International Standard (IS) for whole blood folate. The preparation was assayed using a variety of microbiological and protein-binding methodologies against local standards and calibrators. A consensus folate content was assigned to 95/528. The inclusion of three whole blood samples in the study with widely differing folate levels demonstrated a considerable reduction in inter-laboratory variability when the folate content of the samples was determined relative to the proposed IS 95/528 rather than to laboratories' local standards and calibrators. Accelerated degradation studies indicated that the folate content of 95/528 is stable when stored at −20°C. On the basis of the results presented here, the World Health Organization Expert Committee on Biological Standardization established 95/528 as an IS for whole blood folate.
Collapse
|
35
|
Collaborative study for establishment of a global standard for the potency assay of human anti-D immunoglobulin. PHARMEUROPA BIO 2004; 2003:9-26. [PMID: 14960260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
An international collaborative study aimed at establishing a global standard for the potency assay of anti-D immunoglobulin was started in 2002. 25 laboratories participated in this study run under the common aegis of the World Health Organization, the United States Food and Drug Administration (US-FDA) and the European Directorate for the Quality of Medicines (EDQM). The potencies of three candidate materials and the US-FDA standard (lot 3) included for comparison were evaluated using AutoAnalyzer, competitive enzyme-linked immunoassay (competitive EIA), flow cytometric methods or own "in-house" methods. Critical reagent, standardised procedures and standardised assay design were provided for either method, where appropriate. Central statistical evaluation of the potency data submitted by the participants was performed using a parallel line model. Agreement between laboratories and assay methods for all samples was observed. Intra-laboratory variability was lowest for laboratories performing flow cytometry and highest for laboratories that performed their in-house methods. Inter-laboratory variability was acceptable for all samples when assayed by AutoAnalyzer, competitive (EIA) and flow cytometric methods. It was concluded that sample A is most suitable to serve as a global standard and that sample C could serve as a reserve European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) batch provided that suitable stability is demonstrated. Sample A was adopted by the Ph. Eur. Commission at its 115th session (March 2003) as the first Ph. Eur. BRP (available from the EDQM: catalog number Y0000219) with the assigned potency of 285 IU/ampoule.
Collapse
|
36
|
Abstract
Three hundred participants, including volunteers from an obsessional support group, filled in questionnaires relating to disgust sensitivity, health anxiety, anxiety, fear of death, fear of contamination and obsessionality as part of an investigation into the involvement of disgust sensitivity in types of obsessions. Overall, the data supported the hypothesis that a relationship does exist between disgust sensitivity and the targeted variables. A significant predictive relationship was found between disgust sensitivity and total scores on the obsessive compulsive inventory (OCI; Psychological Assessment 10 (1998) 206) for both frequency and distress of symptomatology. Disgust sensitivity scores were significantly related to health anxiety scores and general anxiety scores and to all the obsessional subscales, with the exception of hoarding. Additionally, multiple regression analyses revealed that disgust sensitivity may be more specifically related to washing compulsions: frequency of washing behaviour was best predicted by disgust sensitivity scores. Washing distress scores were best predicted by health anxiety scores, though disgust sensitivity entered in the second model. It is suggested that further research on the relationship between disgust sensitivity and obsessionality could be helpful in refining the theoretical understanding of obsessions.
Collapse
|
37
|
A global standard for anti-D immunoglobulin: international collaborative study to evaluate a candidate preparation. Vox Sang 2003; 85:313-21. [PMID: 14633258 DOI: 10.1111/j.0042-9007.2003.00367.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of the study was to evaluate a lyophilized anti-D immunoglobulin preparation to serve as a global standard for potency assays of anti-D immunoglobulin products. MATERIALS AND METHODS The candidate global standard, 01/572, was calibrated against the World Health Organization (WHO) International Reference Preparation (IRP) for anti-D immunoglobulin, human (68/419), along with two reserve candidate reference preparations, in an international collaborative study involving 25 laboratories in 15 countries. The United States Food and Drug Administration (US-FDA) Center for Biologics Evaluation and Research (CBER) Standard for anti-D immunoglobulin, Lot 3, was included for comparison. Most laboratories (20/25) performed AutoAnalyser methodology, competitive enzyme-linked immunoassay (EIA) and/or flow cytometry. RESULTS The overall mean potency of the candidate global standard, 01/572, was 284.5 international units (IU)/ampoule, with an interlaboratory variability, expressed as a percentage geometric coefficient of variation (% gcv), of 9.7. The mean potency of the US Standard was 859.4 IU/ml with an interlaboratory variability of 9.5% gcv, excluding an outlier. The mean potencies of the reserve preparations per ampoule/vial were 110.6 IU and 106.7 IU when calibrated against the IRP, and 112.2 IU and 106.6 IU when calibrated against 01/572, respectively, with interlaboratory % gcv values of 9.6-18.3 (excluding outliers). CONCLUSIONS Preparation 01/572 proved more suitable for use as a global standard than the reserve candidate preparations and was established, with an assigned potency of 285 IU/ampoule, by the WHO as the 2nd International Standard for anti-D immunoglobulin; by FDA-CBER as the Standard for anti-D immunoglobulin, Lot 4; and by the European Directorate for the Quality of Medicines (EDQM) as the 1st Biological Reference Preparation for anti-D immunoglobulin.
Collapse
|
38
|
Batches of intravenous immunoglobulin associated with adverse reactions in recipients contain atypically high anti-Rh D activity. Vox Sang 2003; 85:80-4. [PMID: 12925158 DOI: 10.1046/j.1423-0410.2003.00336.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVES The presence of anti-Rh D in intravenous immunoglobulin (IVIG) products has been claimed to be associated with adverse reactions in recipients. There is currently no regulatory specification to control the level of anti-D in IVIG products and it is unclear what this should be. Two reports of haemolysis occurring in recipients of IVIG manufactured from US plasma provided a rare opportunity to investigate whether high anti-D levels could have induced the haemolysis. MATERIALS AND METHODS We developed a direct microtitre plate haemagglutination method suitable for screening IVIG products and starting plasma pools for haemagglutinating activity. RESULTS Of 101 batches of IVIG tested, six were found to contain specific anti-D. Four of these batches had anti-D titres ranging from 64 to 256 (including the two batches each associated with a report of haemolysis) and could be linked, in each case, to a starting plasma pool also positive for anti-D. CONCLUSIONS Our results show that IVIG products can contain appreciable anti-D levels. To avoid potential problems in recipients, we propose an anti-D titre of 8 as the maximum permissible limit of anti-D in IVIG products for batch acceptance and release. The availability of a reference preparation is essential for control of this proposed requirement.
Collapse
|
39
|
Abstract
The development of monoclonal immunoglobulin G (IgG) anti-D for prophylaxis necessitates estimation of their potency in terms of their red cell-binding ability, but it is unclear which quantification methodology is most suitable for this. The aim of this study was to assess 50 monoclonal anti-D from the 4th International Workshop for quantitative and qualitative binding to red cells in a competitive enzyme-linked immunoassay (EIA) in which varying amounts of monoclonal antibodies (MoAbs) and a constant amount of biotinylated monoclonal anti-D (BRAD-5) compete for red cell binding. The potencies of the MoAb were estimated against the International Reference Preparation (IRP) for anti-D Ig. Two MoAbs as supplied were insufficiently inhibitory of biotinylated BRAD-5 binding to be quantified; the potencies of the remainder ranged from 4 to 343 IU mL-1 and included 11 MoAbs showing dose-responses that were nonparallel to those of other MoAb and the IRP. Estimation of the concentration of antibody in the supernatants by radial immunodiffusion ranged from 0.5 to 61 micro g mL-1, giving specific activities of <1-24 IU micro g-1. The results show that competitive EIA is suitable for quantitating most monoclonal anti-D for development and quality control purposes, regardless of their D epitope reactivity.
Collapse
|
40
|
Abstract
BACKGROUND Fear, embarrassment and stigma are salient factors contributing to reluctance to seek help for psychological distress. Although vignette studies have often been employed to assess attitudes towards psychological disorders, no study has specifically assessed attitudes towards Obsessive-Compulsive Disorder (OCD). METHODS An experimental study assessing attitudes toward obsessive-compulsive problems is presented. One hundred and thirteen undergraduate students were given vignettes describing three subtypes of obsessive-compulsive problem (harming, washing and checking). They were asked to make judgements about fear, shame and social acceptance, and to evaluate how they themselves might feel if they experienced the problems described in the vignettes. RESULTS The obsessive-compulsive problems described in the vignettes were evaluated differently in terms of shame, fear and social acceptance. The harming problems were rated as being the most unacceptable, followed by the washing behaviour, and then the checking behaviour. CONCLUSION The findings suggest that attitudes to obsessive-compulsive problems are likely to be complex and that help-seeking influences may vary across the different subtypes of this disorder. The implications for people seeking help for obsessive-compulsive problems are pointed out.
Collapse
|
41
|
Neutralizing increases discomfort associated with obsessional thoughts: An experimental study with obsessional patients. JOURNAL OF ABNORMAL PSYCHOLOGY 2003; 112:709-15. [PMID: 14674881 DOI: 10.1037/0021-843x.112.4.709] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cognitive-behavioral theories suggest that the development of neutralizing is crucial in the development and persistence of obsessional problems (OCD). Twenty-nine patients with a Diagnostic and Statistical Manual of Mental Disorders (4th ed., American Psychiatric Association, 1994) diagnosis of OCD were randomly allocated to 2 conditions. Both listened to repeated recorded presentations of their intrusive thoughts and either neutralized (experimental group) or distracted themselves (control). Discomfort was rated during this 1st phase and then during a 2nd phase without neutralizing or distraction. The experimental group showed a similar level of discomfort in the 1st phase, which significantly reduced during the period compared with controls. The experimental group experienced significantly more discomfort during the 2nd phase, and significantly stronger urges to neutralize and distract at the end of this phase than controls.
Collapse
|
42
|
Abstract
Circulating human antimouse antibodies (HAMAs) directed to mouse immunoglobulin G (IgG) are clinically significant, compromising mouse antibody therapy and imaging, and interfering in immunological assays. To investigate the HAMA response, 20 stable cell lines secreting human monoclonal antibodies reactive with mouse IgG were established from a donor with a history of exposure to mice. Their subclass and domain specificities were established by solid-phase binding, indirect haemagglutination assays and immunoblotting, using Igs of known subclass and Ig fragments. The heavy-chain variable region gene usage was determined for 12 HAMAs. Eight HAMAs were IgM, 11 HAMAs were IgG4 and one HAMA was IgG1, indicating an IgG4-dominated response. All of the IgG HAMAs reacted with epitopes present on the Fc portion; one was subclass-specific, nine were subclass-restricted and two were pan-IgG-reactive. Measurement of their affinities gave dissociation constants typically in the nanomolar range. Seven and five HAMAs were derived from variable heavy-chain 3 (VH3) and VH1 gene segments, respectively. The IgG HAMAs used different VH segments to the IgM HAMAs. JH regions were coded by JH4 in eight HAMAs. DH segment usage appeared to be restricted in the IgM HAMAs. Two IgG HAMAs were clonally related. These monoclonal HAMAs are potentially useful as reagents for detecting mouse IgG and as reference reagents for the investigation of the HAMA response in patients undergoing mouse monoclonal antibody therapy and for the investigation of the influence of HAMAs on immunodiagnostic tests.
Collapse
|
43
|
A stable lyophilized reagent for use in a potential reference assay for quantitation of anti-D in immunoglobulin products. Biologicals 2002; 30:315-21. [PMID: 12421589 DOI: 10.1006/biol.2002.0347] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Quality control of anti-D immunoglobulins intended for in vivo clinical use requires in vitro assay of potency. A lyophilized biotinylated monoclonal anti-D (biotinylated Brad-5; 99/698) has been evaluated for its suitability to serve as a working reagent in a competitive enzyme-linked immunoassay (EIA) for anti-D quantitation. The reagent demonstrated acceptable stability in accelerated degradation tests and following reconstitution. Twelve international laboratories obtained comparable potencies for each of nine anti-D samples using 99/698 in a standardized assay procedure using erythrocytes fixed to microtitre plates. We also describe the use of trehalose for stabilization of dried erythrocyte-coated microtitre plates.
Collapse
|
44
|
International collaborative study to evaluate methods for quantification of anti-D in immunoglobulin preparations. Vox Sang 2002; 83:42-50. [PMID: 12100388 DOI: 10.1046/j.1423-0410.2002.00169.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVES The disadvantages of autoanalyser methodology for anti-D potency estimation have prompted the search for an alternative reference method. The aim of this study was to carry out a direct comparison of autoanalyser methodology, competitive enzyme-linked immunoassay (EIA) and flow cytometry. MATERIALS AND METHODS The anti-D potencies of nine immunoglobulin preparations were estimated against the World Health Organization (WHO) International Reference Preparation for anti-D immunoglobulin, using the three different assay methods described above, in an international collaborative study involving 18 laboratories. RESULTS No significant differences in potency estimates for five of nine samples were identified using the three different methods. For six of nine samples the mean potency estimates obtained using competitive EIA lay between those of the autoanalyser and flow cytometry. Flow cytometry gave the lowest estimates for seven of nine samples. The range of intralaboratory variability, expressed as percentage geometric coefficients of variation (% gcv) and excluding extreme values, was as follows: autoanalyser (eight laboratories), 0.4-17.0; competitive EIA (12 laboratories), 2.6-34.8; and flow cytometry (eight laboratories), 2.9-30.0. The range of interlaboratory variability (expressed as % gcv) was: autoanalyser (eight laboratories, eight samples), 10.8-17.6; competitive EIA (12 laboratories, nine samples), 10.3-17.3; flow cytometry (nine laboratories, eight samples), 6.2-16.1. CONCLUSIONS The study did not show clear superiority of one method over the others. Both competitive EIA and flow cytometry are acceptable alternatives to autoanalyser methodology for polyclonal anti-D potency estimation. For monoclonal anti-D, further work is necessary to determine the most appropriate method for potency testing.
Collapse
|
45
|
Abstract
We have shown that two of the matrix metalloproteinases (MMPs), matrilysin and stromelysin-1, are capable of cleaving all of the human IgG subclasses. The cleavage occurs at a conserved site in the CH(2) domain of the heavy chain of IgG, releasing a single chain Fc-like fragment. We have not been able to demonstrate cleavage of IgA, IgD, IgM or IgE classes, which lack the cleavage site, nor could we show cleavage of IgG by collagenase, gelatinase, macrophage metalloelastase or membrane-type (MT)-MMP. This cleavage of IgG, by separating the antigen-binding (Fabprime prime or minute)(2) from the Fc portion, will remove much of the immunoglobulins' functionality, e.g. complement fixation, Fc receptor binding. In the context of a tumour producing matrilysin or stromelysin, this may represent a way in which the tumour protects itself from ADCC. In inflamed or damaged tissues where plasma protein leakage occurs, degradation by MMPs may be a mechanism for clearance of IgG.
Collapse
|
46
|
Abstract
It is generally believed that the acuity of the peripheral visual field is too poor to allow accurate object recognition and, that to be identified, most objects need to be brought into foveal vision by using saccadic eye movements. However, most measures of form vision in the periphery have been done at eccentricities below 10 degrees and have used relatively artificial stimuli such as letters, digits and compound Gabor patterns. Little is known about how such data would apply in the case of more naturalistic stimuli. Here humans were required to categorize briefly flashed (28 ms) unmasked photographs of natural scenes (39 degrees high, and 26 degrees across) on the basis of whether or not they contained an animal. The photographs appeared randomly in nine locations across virtually the entire extent of the horizontal visual field. Accuracy was 93.3% for central vision and decreased almost linearly with increasing eccentricity (89.8% at 13 degrees, 76.1% at 44.5 degrees and 71.2% at 57.5 degrees ). Even at the most extreme eccentricity, where the images were centred at 70.5 degrees, subjects scored 60.5% correct. No evidence was found for hemispheric specialization. This level of performance was achieved despite the fact that the position of the image was unpredictable, ruling out the use of precued attention to target locations. The results demonstrate that even high-level visual tasks involving object vision can be performed using the relatively coarse information provided by the peripheral retina.
Collapse
|
47
|
Is it a bird? Is it a plane? Ultra-rapid visual categorisation of natural and artifactual objects. Perception 2001; 30:655-68. [PMID: 11464555 DOI: 10.1068/p3029] [Citation(s) in RCA: 204] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Visual processing is known to be very fast in ultra-rapid categorisation tasks where the subject has to decide whether a briefly flashed image belongs to a target category or not. Human subjects can respond in under 400 ms, and event-related-potential studies have shown that the underlying processing can be done in less than 150 ms. Monkeys trained to perform the same task have proved even faster. However, most of these experiments have only been done with biologically relevant target categories such as animals or food. Here we performed the same study on human subjects, alternating between a task in which the target category was 'animal', and a task in which the target category was 'means of transport'. These natural images of clearly artificial objects contained targets as varied as cars, trucks, trains, boats, aircraft, and hot-air balloons. However, the subjects performed almost identically in both tasks, with reaction times not significantly longer in the 'means of transport' task. These reaction times were much shorter than in any previous study on natural-image processing. We conclude that, at least for these two superordinate categories, the speed of ultra-rapid visual categorisation of natural scenes does not depend on the target category, and that this processing could rely primarily on feed-forward, automatic mechanisms.
Collapse
|
48
|
Abstract
The short response latencies of face selective neurons in the inferotemporal cortex impose major constraints on models of visual processing. It appears that visual information must essentially propagate in a feed-forward fashion with most neurons only having time to fire one spike. We hypothesize that flashed stimuli can be encoded by the order of firing of ganglion cells in the retina and propose a neuronal mechanism, that could be related to fast shunting inhibition, to decode such information. Based on these assumptions, we built a three-layered neural network of retino-topically organized neuronal maps. We showed, by using a learning rule involving spike timing dependant plasticity, that neuronal maps in the output layer can be trained to recognize natural photographs of faces. Not only was the model able to generalize to novel views of the same faces, it was also remarkably resistant to image noise and reductions in contrast.
Collapse
|
49
|
Rate coding versus temporal order coding: what the retinal ganglion cells tell the visual cortex. Neural Comput 2001; 13:1255-83. [PMID: 11387046 DOI: 10.1162/08997660152002852] [Citation(s) in RCA: 214] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
It is often supposed that the messages sent to the visual cortex by the retinal ganglion cells are encoded by the mean firing rates observed on spike trains generated with a Poisson process. Using an information transmission approach, we evaluate the performances of two such codes, one based on the spike count and the other on the mean interspike interval, and compare the results with a rank order code, where the first ganglion cells to emit a spike are given a maximal weight. Our results show that the rate codes are far from optimal for fast information transmission and that the temporal structure of the spike train can be efficiently used to maximize the information transfer rate under conditions where each cell needs to fire only one spike.
Collapse
|
50
|
Enhanced efficacy of anti-D immunoglobulin for treating ITP is not explained by higher immunoglobulin polymer content. Biologicals 2001; 29:75-9. [PMID: 11580212 DOI: 10.1006/biol.2001.0279] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Several reports have suggested that low dose anti-D immunoglobulin is superior to high dose immunoglobulin for treatment of idiopathic thrombocytopenia purpura (ITP). However, some findings suggest that it is not the anti-D activity per se that is responsible for efficacy for treatment of ITP with anti-D immunoglobulin. Amongst alternative explanations for the mechanism of action is a relatively higher immunoglobulin polymer content of anti-D compared to other immunoglobulin products, which is more efficient in causing reticuloendothelial Fc receptor blockade. In order to investigate this we have evaluated the polymeric IgG content of anti-D and other immunoglobulin products. Different products showed considerable variation in immunoglobulin polymer content. There was no clear correlation between aggregate or dimer content and product type and anti-D as a class of product did not contain higher amounts of either dimer or aggregate compared to other products. Some manufacturers' products increased in polymer content on storage, but others did not show this effect. Therefore, higher immunoglobulin dimer and/or aggregate content cannot explain the increased efficacy of anti-D immunoglobulin for treatment of ITP. The role of polymeric Ig in efficacy for treatment of ITP is unclear.
Collapse
|