1
|
Benchtop mesoSPIM: a next-generation open-source light-sheet microscope for cleared samples. Nat Commun 2024; 15:2679. [PMID: 38538644 PMCID: PMC10973490 DOI: 10.1038/s41467-024-46770-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 03/08/2024] [Indexed: 04/04/2024] Open
Abstract
In 2015, we launched the mesoSPIM initiative, an open-source project for making light-sheet microscopy of large cleared tissues more accessible. Meanwhile, the demand for imaging larger samples at higher speed and resolution has increased, requiring major improvements in the capabilities of such microscopes. Here, we introduce the next-generation mesoSPIM ("Benchtop") with a significantly increased field of view, improved resolution, higher throughput, more affordable cost, and simpler assembly compared to the original version. We develop an optical method for testing detection objectives that enables us to select objectives optimal for light-sheet imaging with large-sensor cameras. The improved mesoSPIM achieves high spatial resolution (1.5 µm laterally, 3.3 µm axially) across the entire field of view, magnification up to 20×, and supports sample sizes ranging from sub-mm up to several centimeters while being compatible with multiple clearing techniques. The microscope serves a broad range of applications in neuroscience, developmental biology, pathology, and even physics.
Collapse
Grants
- U01 NS090475 NINDS NIH HHS
- This work was supported by the University Research Priority Program (URPP) “Adaptive Brain Circuits in Development and Learning (AdaBD)” of the University of Zurich (N.V., E.S. and F.H.). Additionally, F.F.V. is supported by an HFSP fellowship (LT00687), T.N. received funding from H2020 Marie Skłodowska-Curie Actions (xenCAKUT - 891127), A.R. and S.H. were supported by a Dutch Science Foundation VIDI Grant (14637), and A.R. was supported by an ERC Starting Grant (MULTICONNECT, 639938). Further funding support came from the Swiss National Science Foundation (SNF grant nos. 31003B-170269, 310030_192617 and CRSII5-18O316 to F.H., 310030_189102 to S.S.L., 200020_204950 to L.B., G.R.A, and V.A.); from an ERC Starting Grant by the European Union’s Horizon 2020 Research and Innovation Programme (grant agreement no. 804474, DiRECT, S.S.L); and the US Brain Initiative (1U01NS090475-01, F.H.).
Collapse
|
2
|
Reflective multi-immersion microscope objectives inspired by the Schmidt telescope. Nat Biotechnol 2024; 42:65-71. [PMID: 36997681 PMCID: PMC10791577 DOI: 10.1038/s41587-023-01717-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 02/20/2023] [Indexed: 04/03/2023]
Abstract
Imaging large, cleared samples requires microscope objectives that combine a large field of view (FOV) with a long working distance (WD) and a high numerical aperture (NA). Ideally, such objectives should be compatible with a wide range of immersion media, which is challenging to achieve with conventional lens-based objective designs. Here we introduce the multi-immersion 'Schmidt objective' consisting of a spherical mirror and an aspherical correction plate as a solution to this problem. We demonstrate that a multi-photon variant of the Schmidt objective is compatible with all homogeneous immersion media and achieves an NA of 1.08 at a refractive index of 1.56, 1.1-mm FOV and 11-mm WD. We highlight its versatility by imaging cleared samples in various media ranging from air and water to benzyl alcohol/benzyl benzoate, dibenzyl ether and ethyl cinnamate and by imaging of neuronal activity in larval zebrafish in vivo. In principle, the concept can be extended to any imaging modality, including wide-field, confocal and light-sheet microscopy.
Collapse
|
3
|
The Benchtop mesoSPIM: a next-generation open-source light-sheet microscope for large cleared samples. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.06.16.545256. [PMID: 38168219 PMCID: PMC10760166 DOI: 10.1101/2023.06.16.545256] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
In 2015, we launched the mesoSPIM initiative (www.mesospim.org), an open-source project for making light-sheet microscopy of large cleared tissues more accessible. Meanwhile, the demand for imaging larger samples at higher speed and resolution has increased, requiring major improvements in the capabilities of light-sheet microscopy. Here, we introduce the next-generation mesoSPIM ("Benchtop") with significantly increased field of view, improved resolution, higher throughput, more affordable cost and simpler assembly compared to the original version. We developed a new method for testing objectives, enabling us to select detection objectives optimal for light-sheet imaging with large-sensor sCMOS cameras. The new mesoSPIM achieves high spatial resolution (1.5 μm laterally, 3.3 μm axially) across the entire field of view, a magnification up to 20x, and supports sample sizes ranging from sub-mm up to several centimetres, while being compatible with multiple clearing techniques. The new microscope serves a broad range of applications in neuroscience, developmental biology, and even physics.
Collapse
|
4
|
Moloney Murine Leukemia Virus: A Powerful Tool to Genetically Manipulate Cardiac and Noncardiac Fibroblasts. Thorac Cardiovasc Surg 2022. [DOI: 10.1055/s-0042-1742785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
5
|
MYOTONIC DYSTROPHY. Neuromuscul Disord 2021. [DOI: 10.1016/j.nmd.2021.07.257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Is there a role for bisphosphonates in vascular calcification in chronic kidney disease? Bone 2021; 142:115751. [PMID: 33188959 DOI: 10.1016/j.bone.2020.115751] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 10/28/2020] [Accepted: 11/09/2020] [Indexed: 01/15/2023]
Abstract
Theoretically bisphosphonates could accelerate or retard vascular calcification. In subjects with low GFR, the position is further confounded by a combination of uncertain pharmacokinetics (GI absorption is poor and inconsistent at all levels of renal function and the effect of low GFR generally is to increase bioavailability) and a highly variable skeletal substrate with extremes of turnover that increase unpredictably further. Although bisphosphonates reduce bone formation by 70-90% in subjects with normal GFR and reduce the ability of bone to buffer exogenous calcium fluxes, in bisphosphonate treated postmenopausal women accelerated vascular calcification has not been documented. The kidneys assist with this buffering, but the capacity to modulate calcium excretion declines as GFR falls, increasing the risk of hypercalcaemia in the event of high calcium influx. In the ESRD patient, decreased buffering capacity substantially increases the risk of transient hypercalcaemia, especially in the setting of dialysis, and as such may promote vascular calcification which is highly prevalent in the CKD population. Low bone turnover may thus be less of a vascular problem in patients with preserved renal function and a bigger problem when the GFR is low. In patients with stage 4 and 5 CKD, adynamic bone disease associates with the severity and progression of arterial calcification, including coronary artery calcification, and further suppression of bone turnover by a bisphosphonate might exacerbate an already high predisposition to vascular calcification. No convincing signal of harm has emerged from clinical studies thus far. For example 51 individuals with CKD stage 3-4 treated with either alendronate 70 mg per week or placebo for 18 months showed no difference in the rate of vascular calcifications. Conversely an observational study of women with stage 3-4 CKD with pre-existing cardiovascular disease found an increased risk of mortality with a hazard ratio of 1.22 (1.04-1.42) in those given bisphosphonates. Direct suppression of vascular calcification by bisphosphonates is probably confined to etidronate - treatment of soft tissue calcification was a recognized indication for this drug and etidronate markedly reduced progression of vascular calcification in CKD patients. Bisphosphonates are analogues of pyrophosphate, a potent calcification inhibitor in bone and soft tissue. Thus the efficacy of etidronate as treatment for soft tissue calcification brought with it a problematic tendency to cause osteomalacia. In contrast, conventional doses of nitrogen-containing bisphosphonates fail to yield circulating concentrations sufficient to exert direct anti-calcifying effects, at least in patients with good renal function and studies using alendronate and ibandronate have yielded inconsistent vascular outcomes.
Collapse
|
7
|
hFRUIT: An optimized agent for optical clearing of DiI-stained adult human brain tissue. Sci Rep 2020; 10:9950. [PMID: 32561795 PMCID: PMC7305111 DOI: 10.1038/s41598-020-66999-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Accepted: 05/28/2020] [Indexed: 11/09/2022] Open
Abstract
Here, we describe a new immersion-based clearing method suitable for optical clearing of thick adult human brain samples while preserving its lipids and lipophilic labels such as 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI). This clearing procedure is simple, easy to implement, and allowed for clearing of 5 mm thick human brain tissue samples within 12 days. Furthermore, we show for the first time the advantageous effect of the Periodate-Lysine-Paraformaldehyde (PLP) fixation as compared to the more commonly used 4% paraformaldehyde (PFA) on clearing performance.
Collapse
|
8
|
The mesoSPIM initiative: open-source light-sheet microscopes for imaging cleared tissue. Nat Methods 2019; 16:1105-1108. [PMID: 31527839 PMCID: PMC6824906 DOI: 10.1038/s41592-019-0554-0] [Citation(s) in RCA: 107] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 07/31/2019] [Accepted: 08/06/2019] [Indexed: 11/09/2022]
Abstract
Light-sheet microscopy is an ideal technique for imaging large cleared samples; however, the community is still lacking instruments capable of producing volumetric images of centimeter-sized cleared samples with near-isotropic resolution within minutes. Here, we introduce the mesoscale selective plane-illumination microscopy initiative, an open-hardware project for building and operating a light-sheet microscope that addresses these challenges and is compatible with any type of cleared or expanded sample ( www.mesospim.org ).
Collapse
|
9
|
Scalable Labeling for Cytoarchitectonic Characterization of Large Optically Cleared Human Neocortex Samples. Sci Rep 2019; 9:10880. [PMID: 31350519 PMCID: PMC6659684 DOI: 10.1038/s41598-019-47336-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 07/12/2019] [Indexed: 01/27/2023] Open
Abstract
Optical clearing techniques and light sheet microscopy have transformed fluorescent imaging of rodent brains, and have provided a crucial alternative to traditional confocal or bright field techniques for thin sections. However, clearing and labeling human brain tissue through all cortical layers and significant portions of a cortical area, has so far remained extremely challenging, especially for formalin fixed adult cortical tissue. Here, we present MASH (Multiscale Architectonic Staining of Human cortex): a simple, fast and low-cost cytoarchitectonic labeling approach for optically cleared human cortex samples, which can be applied to large (up to 5 mm thick) formalin fixed adult brain samples. A suite of small-molecule fluorescent nuclear and cytoplasmic dye protocols in combination with new refractive index matching solutions allows deep volume imaging. This greatly reduces time and cost of imaging cytoarchitecture in thick samples and enables classification of cytoarchitectonic layers over the full cortical depth. We demonstrate application of MASH to large archival samples of human visual areas, characterizing cortical architecture in 3D from the scale of cortical areas to that of single cells. In combination with scalable light sheet imaging and data analysis, MASH could open the door to investigation of large human cortical systems at cellular resolution and in the context of their complex 3-dimensional geometry.
Collapse
|
10
|
High resolution anatomical and quantitative MRI of the entire human occipital lobe ex vivo at 9.4T. Neuroimage 2017; 168:162-171. [PMID: 28336427 PMCID: PMC5862655 DOI: 10.1016/j.neuroimage.2017.03.039] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 03/17/2017] [Accepted: 03/19/2017] [Indexed: 11/06/2022] Open
Abstract
Several magnetic resonance imaging (MRI) contrasts are sensitive to myelin content in gray matter in vivo which has ignited ambitions of MRI-based in vivo cortical histology. Ultra-high field (UHF) MRI, at fields of 7 T and beyond, is crucial to provide the resolution and contrast needed to sample contrasts over the depth of the cortex and get closer to layer resolved imaging. Ex vivo MRI of human post mortem samples is an important stepping stone to investigate MRI contrast in the cortex, validate it against histology techniques applied in situ to the same tissue, and investigate the resolutions needed to translate ex vivo findings to in vivo UHF MRI. Here, we investigate key technology to extend such UHF studies to large human brain samples while maintaining high resolution, which allows investigation of the layered architecture of several cortical areas over their entire 3D extent and their complete borders where architecture changes. A 16 channel cylindrical phased array radiofrequency (RF) receive coil was constructed to image a large post mortem occipital lobe sample (~80×80×80 mm3) in a wide-bore 9.4 T human scanner with the aim of achieving high-resolution anatomical and quantitative MR images. Compared with a human head coil at 9.4 T, the maximum Signal-to-Noise ratio (SNR) was increased by a factor of about five in the peripheral cortex. Although the transmit profile with a circularly polarized transmit mode at 9.4 T is relatively inhomogeneous over the large sample, this challenge was successfully resolved with parallel transmit using the kT-points method. Using this setup, we achieved 60μm anatomical images for the entire occipital lobe showing increased spatial definition of cortical details compared to lower resolutions. In addition, we were able to achieve sufficient control over SNR, B0 and B1 homogeneity and multi-contrast sampling to perform quantitative T2* mapping over the same volume at 200 μm. Markov Chain Monte Carlo sampling provided maximum posterior estimates of quantitative T2* and their uncertainty, allowing delineation of the stria of Gennari over the entire length and width of the calcarine sulcus. We discuss how custom RF receive coil arrays built to specific large post mortem sample sizes can provide a platform for UHF cortical layer-specific quantitative MRI over large fields of view. Custom-built 16 channel 9.4 T RF-coil to image large post mortem samples at high resolution. Parallel transmit techniques allow homogenization of B1+ for 3D GRE imaging at UHF. 60 μm anatomical MRI of the entire human occipital lobe. 200 μm isotropic quantitative T2* mapping of the entire human occipital lobe. A platform for future UHF cortical layer specific qMRI over large FoVs.
Collapse
|
11
|
Long-term results for treatment of patients with unprotected left main stenosis by CABG or PCI with Drug Eluting Stents. A prospective registry. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht308.p2176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
12
|
Qualifications and training of adult stem cell donor recruiters: recommendations by the World Marrow Donor Association. Bone Marrow Transplant 2012; 48:148-50. [PMID: 22635248 DOI: 10.1038/bmt.2012.98] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
13
|
Abstract
Professional peer review of random prior radiologist's interpretations is mandated by the Joint Commission on Accreditation of Healthcare Organizations (JCAHO). The JCAHO expects documentation of 5% rate of random peer-review cases. Countless hours are spent in departments fulfilling these requirements. The integration of the peer-review process into the radiologist's interpretation workflow was expected to increase the percentage of documented peer review, yet decrease the time and effort for this documentation. radStation clinical review workstations are deployed at every reading station. When a requisition is bar-coded, radStation retrieves the patient's clinical information and automatically displays the prior comparison report. If the radiologist agrees with the prior report, a single click on a "quality assurance' agree box documents the agreement. In the case of a discordance, an additional dialog box automatically appears and the radiologist enters the reason for disagreement and then submits the case as a discrepancy. The system holds the discordance for 3 to 5 working days, then notifies the original radiologist via E-mail that a prior interpretation has been submitted for peer review, lists the submitted discrepancy reason, and provides a link to display the discordant report. The peer-review database is separate from the existing radiology information system (RIS). At the end of every month, summary reports of all peer-review activity are generated automatically. Initial benchmarks of our deployed system anticipate documentation of long-term random peer-review rate at greater than 50% of interpreted cases. The system enhances the peer-review process by integrating it with the normal interpretation workflow. The time to complete peer review using radStation is less than 1 second per normal case and less than 60 seconds for a discordant case. The E-mail notification system is fully automated, eliminating the need for secretarial involvement in the data collection. This system has completely replaced a manual paper-based system. The integration of peer review directly into the radiologist's interpretation workstation greatly enhances the capability to easily exceed JCAHO standards. The overall increase in peer-review documentation should continue to improve the ability to document a consistent high quality of patient care.
Collapse
|
14
|
Radiologist's clinical information review workstation interfaced with digital dictation system. J Digit Imaging 2000; 13:45-8. [PMID: 10847361 PMCID: PMC3453296 DOI: 10.1007/bf03167623] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Efficient access to information systems integrated into the radiologist's interpretation workflow will result in a more informed radiologist, with an enhanced capability to render an accurate interpretation. We describe our implementation of radStation, a radiologist's clinical information review workstation that combines a digital dictation station with a clinical information display. radStation uses client software distributed to the radiologist's workstation and central server software, both running Windows NT (Microsoft, Redmond, WA). The client system has integrated digital dictation software. The bar-code microphone (Boomerang, Dictaphone Corp, Stratford, CT) also serves as a computer input device forwarding the procedure's accession number to the server software. This initiates multiple queries to available legacy databases, including the radiology information system (RIS), laboratory information system, clinic notes, hospital discharge, and operative report system. The three-tier architecture then returns the clinical results to the radStation client for display. At the conclusion of the dictation, the digital voice file is transferred to the dictation server and the client notifies the RIS to update the examination status. The system is efficient in its information retrieval, with queries displayed in about 1 second. The radStation client requires less than 5 minutes of radiologist training in its operation, given that its control interface integrates with the well-learned dictation process. The telephone-based dictation system, which this new system replaced, remains available as a back-up system in the event of an unexpected digital dictation system failure. This system is well accepted and valued by the radiologists. The system interface is quickly mastered. The system does not interrupt dictation workflow with the display of all information initiated with examination bar-coding. This system's features could become an accepted model as a standard tool for radiologists.
Collapse
|
15
|
RadStation: client-based digital dictation system and integrated clinical information display with an embedded Web-browser. Proc AMIA Symp 2000:561-4. [PMID: 11079946 PMCID: PMC2244112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023] Open
Abstract
RadStation is a digital dictation system having an integrated display of clinical information. The three-tiered system architecture provides robust performance, with most information displayed within one second after a request. The multifunctional client tier is a unique client/browser hybrid. A Web browser display window functions as the client application's data display window for clinical information, radiology reports, and laboratory and pathology results. RadStation provides a robust platform for digital dictation functionality. The system's internal status checks ensure operational integrity in a clinical environment. Also, the programmable dictation microphone and bar-code reader supplant the mouse as the system's primary input device. By merging information queries into existing work flow, radiologist's interpretation efficiency is maintained with instant access to essential clinical information. Finally, RadStation requires minimal training and has been enthusiastically accepted by our radiologists in an active clinical practice.
Collapse
|
16
|
Abstract
Sixty-seven foals age < 150 days underwent a ventral celiotomy for colic. Of the 67 foals, 51 foals (82%) recovered from anaesthesia and 42 (63%) were subsequently released from the hospital. Three (6%) of the 51 foals were subjected to a repeat celiotomy. Long term follow-up was available on 36 foals. Twenty-nine (57%) of the 51 foals recovered from anaesthesia, were alive at least 2 years following surgery. Adhesions were identified in 8 (17%) of the foals which recovered from general anaesthesia but were subsequently subjected to euthanasia due to recurrent colic. Strangulating lesions were associated with a lower survival rate. Nineteen per cent of foals with strangulating intestinal lesions survived > 2 years following surgery, compared to 69% of foals with nonstrangulating lesions. The age of foals on admission had a significant effect on survival. Only 10% of foals less than 14 days of age survived, compared to 45.8% of foals between age 15 and 150 days.
Collapse
|
17
|
Beyond the niceties of networking: schools shrug off traditional boundaries for better education and the future of the profession. Nurse Educ 1995; 20:15-6. [PMID: 7770156 DOI: 10.1097/00006223-199503000-00008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
18
|
Light-scattering spectroscopy of the liquid-glass transition in CaKNO3 and in the molecular glass Salol: Extended-mode-coupling-theory analysis. PHYSICAL REVIEW. E, STATISTICAL PHYSICS, PLASMAS, FLUIDS, AND RELATED INTERDISCIPLINARY TOPICS 1993; 47:4223-4239. [PMID: 9960499 DOI: 10.1103/physreve.47.4223] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
19
|
Abstract
In summary, neuromuscular blocking agents can be used safely and to advantage in equine anesthesia. Muscle-relaxant use in equine anesthesia has been helped by the development of new relaxants such as atracurium, which has a reliable and reproducible duration of action. There are certain cases that benefit particularly by the use of relaxants but their use is not limited to these cases. These cases involve horses that experience persistent movement and hypotension during anesthesia, are undergoing ophthalmic or abdominal surgery or fracture repair, or are severely ill. Horses receiving muscle relaxants during anesthesia require mechanical ventilation, and neuromuscular blockade should be monitored with a peripheral-nerve stimulator.
Collapse
|
20
|
Using storytelling to teach relaxation to children. THE KANSAS NURSE 1988; 63:16. [PMID: 3050244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
21
|
A collaborative effort to implement differentiated case management delivery system: a new direction for the future of nursing. THE KANSAS NURSE 1988; 63:1-2. [PMID: 3357282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
22
|
Abstract
Circulating immune complexes were determined in the sera of patients with ankylosing spondylitis using a polyethylene glycol precipitation laser nephelometer technique. Positive results were obtained in 52% of sera from patients with active disease, but only in 20% from those in inactive stages. The immunoglobulin/complement protein ratio differed from that seen in rheumatoid arthritis and in systemic lupus erythematosus, due to the relatively larger amounts of C3 and C4 present in the immune complexes. These findings indicate that circulating immune complexes in ankylosing spondylitis may not be of pathogenetic significance because of their degree of solubilization.
Collapse
|
23
|
Focus on health: family health assessment. Nurse Pract 1981; 6:37-45, 54. [PMID: 7207900 DOI: 10.1097/00006205-198106020-00008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|