1
|
Use of Thromboelastography in Coronary Artery Bypass Grafting in a Patient With Factor Ⅴ Deficiency With Platelet Function Disorders: A Case Report and Literature Review. Cureus 2024; 16:e58185. [PMID: 38741825 PMCID: PMC11089832 DOI: 10.7759/cureus.58185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/12/2024] [Indexed: 05/16/2024] Open
Abstract
Reports on cases of factor Ⅴ (FⅤ) deficiency complicated by platelet function disorders in patients undergoing cardiac surgery are rare, and the utilization of thromboelastography in such cases is limited. This case presents a unique case of FⅤ deficiency complicated by platelet function disorders, highlighting the significance of tailored transfusion strategies guided by thromboelastography (TEG). A 64-year-old hemodialysis patient who was diagnosed with FⅤ deficiency 24 years prior presented for an on-pump coronary artery bypass graft. The decrease in FⅤ activity on preoperative examination was mild. Based on this finding, it was determined that preoperative fresh frozen plasma supplementation was not required. However, the case was complicated by platelet function disorders; therefore, a preoperative transfusion of platelet concentrate was performed to correct the decreased platelet function, enabling subsequent surgery. Intraoperative and postoperative transfusion strategies were guided by TEG. This study highlights TEG-guided transfusion management as a viable option for patients with FⅤ deficiency complicated by platelet function disorders.
Collapse
|
2
|
Anxiety evaluated by the Hospital Anxiety and Depression Scale as a predictor of postoperative nausea and vomiting: a pilot study. NAGOYA JOURNAL OF MEDICAL SCIENCE 2024; 86:72-81. [PMID: 38505720 PMCID: PMC10945218 DOI: 10.18999/nagjms.86.1.72] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 06/13/2023] [Indexed: 03/21/2024]
Abstract
The incidence of postoperative nausea and vomiting (PONV) remains high, and improving the accuracy of PONV prediction remains challenging. The primary aim of this study is to examine the impact of anxiety scores evaluated using the Hospital Anxiety and Depression Scale (HADS) on the PONV prediction model. We hypothesized that anxiety and depression, quantified using the HADS, could improve the accuracy of the PONV predictive model. This pilot study evaluated 100 patients. The HADS was conducted by a self-evaluation method before thoracoscopic surgery for lung tumors, and the anesthesia method was standardized. The criterion was whether the nurse in charge of the patient who complained of PONV assessed that drug administration was necessary. As the main analysis, the odds ratio of the HADS score for predicting PONV was evaluated using multivariable logistic regression models. Further, the receiver operating characteristic (ROC) curves of the model with the HADS score added to the variables of without-anxiety predictors and the model with the variables of without-anxiety predictors only were compared. The anxiety score was significantly higher in the PONV group than in the no PONV group (P = 0.021). For predictive accuracy, the model that included age, sex, smoking history, history of PONV, and anxiety score had a higher area under the ROC curve than did the model excluding the anxiety score (P = 0.021). In conclusion, the findings indicate that the HADS is worth investigating as a predictor of PONV.
Collapse
|
3
|
Amplitude at 10 min in thromboelastography predicts maximum amplitude: a single-center observational study. J Anesth 2024; 38:136-140. [PMID: 38212407 DOI: 10.1007/s00540-023-03301-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 12/11/2023] [Indexed: 01/13/2024]
Abstract
Thromboelastography is a quantitative test widely used to measure the efficiency of blood clotting. However, awaiting the results of maximum amplitude (MA) is necessary for determining the need for platelet- and fibrinogen-containing products. A more rapid prediction of MA could facilitate faster preparation and administration of blood transfusion products, thereby resulting in coagulation improvement. In this retrospective study, we hypothesized that early amplitude at 10 min (A10) could be a predictor of MA. Therefore, we investigated whether MA can be rapidly inferred from thromboelastographic 6 s (TEG6s) measurements and evaluated its correlation with A10. We extracted TEG6s measurements obtained in operating rooms and intensive care units of our hospital between January 2018 and December 2022. The correlation of MA with display items of TEG6s results, including reaction time, kinetics, α angle, activated clotting time, and A10, was evaluated. The relationship between citrated rapid TEG (CRT)-A10 and CRT-MA, as well as between citrated functional fibrinogen (CFF)-A10 and CFF-MA, were evaluated if A10 and MA showed a good correlation. The results showed good correlations between CRT-A10 and CRT-MA, as well as between CFF-A10 and CFF-MA. Therefore, evaluating A10 using TEG6s could predict MA.
Collapse
|
4
|
Maternal outcomes following postpartum autotransfusion of blood lost during vaginal obstetric hemorrhage. Transfusion 2024; 64:77-84. [PMID: 37997677 DOI: 10.1111/trf.17603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 11/25/2023]
Abstract
BACKGROUND Autotransfusion following vaginal delivery has not been as widely adopted and existing data on this topic are limited to small case series. METHODS This is a single-center retrospective matched cohort study. Deliveries exposed to autotransfusion during obstetric hemorrhage were matched to unexposed controls with obstetric hemorrhage who did not receive autotransfusion. The primary outcome was allogeneic transfusion of packed red blood cells. Planned secondary analyses included change in hemoglobin following delivery, composite maternal safety outcomes, and unplanned postpartum health care utilization. RESULTS Thirty-six deliveries exposed to autotransfusion were matched to 144 unexposed controls. There was no significant difference in allogenic transfusion of packed red blood cells in the patients exposed to autotransfusion red with unexposed controls (adjusted OR 1.1; 95% CI 0.5-2.4). Deliveries that received autotransfusion had a less severe pre- to post-delivery decline in hemoglobin compared with unexposed controls across all values of QBL (p = .003). There were no significant differences in maternal morbidity outcomes evaluated in exposed versus unexposed deliveries. CONCLUSION Autotransfusion in cases of vaginal obstetric hemorrhage did not attenuate rates of allogenic packed red blood cell transfusion but did result in a less severe pre- to postdelivery decline in hemoglobin at discharge. Autotransfusion cases did not have any markers of increased maternal morbidity when compared with a control group. These findings support emerging evidence indicating that autotransfusion of blood lost during vaginal obstetric hemorrhage is a safe and potentially effective tool for use in the management of obstetric hemorrhage.
Collapse
|
5
|
Thromboelastographic evaluation after cardiac surgery optimizes transfusion requirements in the intensive care unit: a single-center retrospective cohort study using an inverse probability weighting method. Gen Thorac Cardiovasc Surg 2024; 72:15-23. [PMID: 37173610 PMCID: PMC10180616 DOI: 10.1007/s11748-023-01941-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 05/07/2023] [Indexed: 05/15/2023]
Abstract
OBJECTIVE There are no reports from Japan showing the effects of using the thromboelastography algorithm on transfusion requirements after Intensive Care Unit (ICU) admission, and post-implementation knowledge regarding the thromboelastography algorithm under the Japanese healthcare system is insufficient. Therefore, this study aimed to clarify the effect of the TEG6s thromboelastography algorithm on transfusion requirements for patients in the ICU after cardiac surgery. METHODS We retrospectively compared the requirements for blood transfusion up to 24 h after ICU admission using the thromboelastography algorithm (January 2021 to April 2022) (thromboelastography group; n = 201) and specialist consultation with surgeons and anesthesiologists (January 2018 to December 2020) (non-thromboelastography group; n = 494). RESULTS There were no significant between-group differences in terms of age, height, weight, body mass index, operative procedure, duration of surgery or cardiopulmonary bypass, body temperature, or urine volume during surgical intervention. Moreover, there was no significant between-group difference in the amount of drainage at 24 h after ICU admission. However, crystalloid and urine volumes were significantly higher in the thromboelastography group than in the non-thromboelastography group. Additionally, fresh-frozen plasma (FFP) transfusion volumes were significantly lower in the thromboelastography group. However, there were no significant between-group differences in red blood cell count or platelet transfusion volume. After variable adjustment, the amount of FFP used from the operating room to 24 h after ICU admission was significantly reduced in the thromboelastography group. CONCLUSIONS The thromboelastography algorithm optimized transfusion requirements at 24 h after admission to the ICU following cardiac surgery.
Collapse
|
6
|
Intraoperative hypotension affects postoperative acute kidney injury depending on the invasiveness of abdominal surgery: A retrospective cohort study. Medicine (Baltimore) 2023; 102:e36465. [PMID: 38050260 PMCID: PMC10695494 DOI: 10.1097/md.0000000000036465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/06/2023] Open
Abstract
Intraoperative hypotension (IOH) or highly invasive surgery adversely affects postoperative clinical outcomes. It is, however, unclear whether IOH affects postoperative acute kidney injury (AKI) depending on the invasiveness of abdominal surgery. We speculated that IOH in highly invasive abdominal surgery is a significant risk factor for postoperative AKI. We retrospectively reviewed the data of 448 patients who underwent abdominal surgery. Patients were divided into 3 groups: highly (such as pancreaticoduodenectomy and hepatectomy), moderately (open abdominal surgery), and minimally (laparoscopic surgery) invasive surgeries. The association between the time-weighted average (TWA) of mean arterial pressure (MAP) values (≤60 and ≤ 55 mm Hg) and AKI occurrences in each group was assessed. Postoperative AKI occurred after highly, moderately, and minimally invasive surgeries in 33 of 222 (14.9%), 14 of 110 (12.7%), and 12 of 116 (10.3%) cases, respectively (P = .526). The median [interquartile range] of TWA-MAP ≤ 60 mm Hg, as an IOH parameter, was 0.94 [0.33-2.08] mm Hg in highly, 0.54 [0.16-1.46] mm Hg in moderately, and 0.14 [0.03-0.57] mm Hg in minimally invasive surgeries (P < 0001). In addition, there was a significant association between TWA-MAP and AKI in highly invasive surgery, unlike in moderately and minimally invasive surgery, with adjusted odds ratios (95% confidence interval) for TWA-MAP ≤ 60 and ≤ 55 mm Hg associated with AKI of 1.23 [1.00-1.52] (P = .049) and 1.55 [1.02-2.36] (P = .041), respectively. Intraoperative MAP ≤ 60 mm Hg in highly invasive abdominal surgery is associated with postoperative AKI, compared to moderately and minimally invasive surgeries. Additionally, low MAP thresholds in highly invasive surgery increase postoperative AKI risk.
Collapse
|
7
|
Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the TeV Region with CALET on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 131:191001. [PMID: 38000434 DOI: 10.1103/physrevlett.131.191001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/31/2023] [Accepted: 10/09/2023] [Indexed: 11/26/2023]
Abstract
Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10^{5}), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from -3.15 to -3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.
Collapse
|
8
|
Administration of lipid emulsion reduced the hypnotic potency of propofol more than that of thiamylal in mice. Exp Anim 2023; 72:468-474. [PMID: 37271538 PMCID: PMC10658092 DOI: 10.1538/expanim.23-0010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 05/19/2023] [Indexed: 06/06/2023] Open
Abstract
Administration in a lipid emulsion can modify the pharmacodynamics of drugs via a process known as lipid resuscitation. However, the detailed mechanism remains unclear. We studied the volume and another pharmacodynamic effect, the lipid sink, using propofol and thiamylal. Male adult mice (ddY) were intravenously administered 10 ml/kg propofol or thiamylal diluted with physiological saline, 10% soybean oil, or 20% soybean oil. The 50% effective dose (ED50) for achieving hypnosis was calculated using probit analysis. To investigate the volume effect, 0, 10, or 20 ml/kg of saline or soybean oil was administered, either simultaneously or beforehand. Next, a two- or three-fold dose of the anesthetics was administered and the durations of anesthesia were measured. Finally, at 30 s after the first injection, supplemental soybean oil was administered. The mean (± SE) ED50 values of propofol and thiamylal were 5.79 mg/kg (0.61) and 8.83 mg/kg (0.84), respectively. Lipid dilution increased the ED50 values of both anesthetics. After injection of a dose two-fold the ED50 value, the respective mean (± SD) durations of anesthesia were 125 ± 35 s and 102 ± 38 s. Supplemental administration of soybean oil significantly shortened the duration of anesthesia of propofol, but not that of thiamylal. The results indicate that administration of a lipid emulsion vitiated the anesthetic effect of propofol by reducing the non-emulsified free fraction in the aqueous phase, which may elucidate the lipid resuscitation likely caused by the lipid sink mechanism.
Collapse
|
9
|
Hypopharyngeal Injury by Transesophageal Echocardiography During Cardiac Surgery. J Cardiothorac Vasc Anesth 2023; 37:2027-2031. [PMID: 37407327 DOI: 10.1053/j.jvca.2023.06.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 06/13/2023] [Accepted: 06/16/2023] [Indexed: 07/07/2023]
|
10
|
Erratum: Charge-Sign Dependent Cosmic-Ray Modulation Observed with the Calorimetric Electron Telescope on the International Space Station [Phys. Rev. Lett. 130, 211001 (2023)]. PHYSICAL REVIEW LETTERS 2023; 131:109902. [PMID: 37739390 DOI: 10.1103/physrevlett.131.109902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Indexed: 09/24/2023]
Abstract
This corrects the article DOI: 10.1103/PhysRevLett.130.211001.
Collapse
|
11
|
Is banning desflurane an essential measure to reduce global warming? Additional issues raised. Eur J Anaesthesiol 2023; 40:534-535. [PMID: 37282725 DOI: 10.1097/eja.0000000000001831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
|
12
|
Charge-Sign Dependent Cosmic-Ray Modulation Observed with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 130:211001. [PMID: 37295105 DOI: 10.1103/physrevlett.130.211001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 03/16/2023] [Accepted: 04/13/2023] [Indexed: 06/12/2023]
Abstract
We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical "drift model" of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.
Collapse
|
13
|
Fibcare ® shows correlation with fibrinogen levels by the Clauss method during cardiopulmonary bypass. NAGOYA JOURNAL OF MEDICAL SCIENCE 2023; 85:310-318. [PMID: 37346828 PMCID: PMC10281844 DOI: 10.18999/nagjms.85.2.310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 07/25/2022] [Indexed: 06/23/2023]
Abstract
Central laboratory measurements are time consuming, while rapid fibrinogen level measurements within the operating room improve transfusion strategies. We aimed to clarify the correlation between fibrinogen concentrations (measured using Fibcare® and the Clauss fibrinogen assay in a central laboratory) during cardiovascular surgery with cardiopulmonary bypass. Data of patients whose Fibcare, traditional laboratory-based testing, and thromboelastographic results were measured using the same blood sample during cardiopulmonary bypass from February 2021 to January 2022 were retrospectively examined. We analyzed correlation in categories of body temperature during cardiopulmonary bypass: total cases, mild hypothermia (28-34°C), and moderate or severe hypothermia (<28°C). The Clauss fibrinogen assay was performed in 123 cases, Fibcare in 107, and thromboelastography in 91. For mild hypothermia, moderate or severe hypothermia, and overall, the root mean squared error and R-square in Fibcare were 16.1 and 0.86, 13.1 and 0.87, and 14.9 and 0.87, respectively, and for thromboelastography, they were 3.26 and 0.74, 2.70 and 0.79, and 3.08 and 0.75, respectively. A significant relationship was noted between Fibcare and Claus fibrinogen analysis regardless of body temperature during cardiopulmonary bypass. The measurement of fibrinogen levels using Fibcare allows for faster transfusion preparation than that of the traditional Clauss fibrinogen assay.
Collapse
|
14
|
Life-threatening chlorhexidine anaphylaxis caused by skin preparation before chlorhexidine-free central venous catheter insertion: a case report and literature review. J Anesth 2023; 37:474-481. [PMID: 37120585 DOI: 10.1007/s00540-023-03189-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 03/29/2023] [Indexed: 05/01/2023]
Abstract
Chlorhexidine is a common cause of perioperative anaphylaxis, and global regulatory authorities have issued warnings about anaphylaxis due to chlorhexidine-containing central venous catheters (CVC) and its mucosal absorption. We present a case of life-threatening anaphylaxis after CVC insertion caused by chlorhexidine used for skin preparation. The onset of anaphylaxis was rapid and very severe, resulting in pulseless electrical activity. The patient was successfully resuscitated by emergency veno-arterial extracorporeal membrane oxygenation (VA-ECMO). Our case suggests that even skin preparation before chlorhexidine-free CVC insertion can cause life-threatening anaphylaxis. We reviewed the literature on chlorhexidine anaphylaxis cases and categorized all potential routes of chlorhexidine exposure to assess the risk following skin preparation. Our results showed that skin preparation before CVC insertion was the third most common cause of chlorhexidine anaphylaxis after transurethral exposure and chlorhexidine-containing CVCs. However, skin preparation with chlorhexidine before CVC insertion was sometimes overlooked as a cause of chlorhexidine anaphylaxis, and its risk might be underestimated. Further, no previous reports have described life-threatening anaphylaxis solely due to chlorhexidine skin preparation before CVC insertion. CVC insertion might cause the chlorhexidine used for skin preparation to reach the vascular system and should be recognized as a potential cause of life-threatening chlorhexidine anaphylaxis.
Collapse
|
15
|
Direct Measurement of the Cosmic-Ray Helium Spectrum from 40 GeV to 250 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 130:171002. [PMID: 37172251 DOI: 10.1103/physrevlett.130.171002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 04/03/2023] [Indexed: 05/14/2023]
Abstract
We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV/n to about 60 TeV/n is also presented, using the CALET proton flux recently updated with higher statistics.
Collapse
|
16
|
Hemodiafiltration combined with polymyxin B-immobilized fiber column direct hemoperfusion is effective for acute postoperative exacerbation of interstitial pneumonia: a case report. JA Clin Rep 2022; 8:100. [PMID: 36575269 PMCID: PMC9794657 DOI: 10.1186/s40981-022-00589-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Postoperative acute exacerbation of interstitial pneumonia has a high mortality rate; however, its treatment methods have not been standardized. CASE PRESENTATION A 72-year-old man with rheumatoid arthritis developed acute respiratory failure about 3 weeks after lung cancer surgery. There were increased diffuse frosted shadows in both lung fields. His condition was diagnosed as an acute exacerbation of interstitial pneumonia associated with rheumatoid arthritis, and he was started on steroid pulse therapy; however, his respiratory condition deteriorated. He was urgently intubated and started on veno-venous extracorporeal membrane oxygenation. Further, intensive care, including blood purification therapy, was initiated. The blood purification therapy comprised a combination of hemodiafiltration and 6-h polymyxin B-immobilized fiber column direct hemoperfusion. The patient was weaned off veno-venous extracorporeal membrane oxygenation, extubated, and discharged from the intensive care unit on the ninth day. CONCLUSIONS Blood purification therapy was effective for acute exacerbation of interstitial pneumonia.
Collapse
|
17
|
Cosmic-Ray Boron Flux Measured from 8.4 GeV/n to 3.8 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 129:251103. [PMID: 36608255 DOI: 10.1103/physrevlett.129.251103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 11/07/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
We present the measurement of the energy dependence of the boron flux in cosmic rays and its ratio to the carbon flux in an energy interval from 8.4 GeV/n to 3.8 TeV/n based on the data collected by the Calorimetric Electron Telescope (CALET) during ∼6.4 yr of operation on the International Space Station. An update of the energy spectrum of carbon is also presented with an increase in statistics over our previous measurement. The observed boron flux shows a spectral hardening at the same transition energy E_{0}∼200 GeV/n of the C spectrum, though B and C fluxes have different energy dependences. The spectral index of the B spectrum is found to be γ=-3.047±0.024 in the interval 25<E<200 GeV/n. The B spectrum hardens by Δγ_{B}=0.25±0.12, while the best fit value for the spectral variation of C is Δγ_{C}=0.19±0.03. The B/C flux ratio is compatible with a hardening of 0.09±0.05, though a single power-law energy dependence cannot be ruled out given the current statistical uncertainties. A break in the B/C ratio energy dependence would support the recent AMS-02 observations that secondary cosmic rays exhibit a stronger hardening than primary ones. We also perform a fit to the B/C ratio with a leaky-box model of the cosmic-ray propagation in the Galaxy in order to probe a possible residual value λ_{0} of the mean escape path length λ at high energy. We find that our B/C data are compatible with a nonzero value of λ_{0}, which can be interpreted as the column density of matter that cosmic rays cross within the acceleration region.
Collapse
|
18
|
Incidence rate of chronic pain after 1.5-2 years of thoracotomy between paravertebral block versus epidural block: a cohort study. NAGOYA JOURNAL OF MEDICAL SCIENCE 2022; 84:752-761. [PMID: 36544613 PMCID: PMC9748327 DOI: 10.18999/nagjms.84.4.752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 12/28/2021] [Indexed: 12/24/2022]
Abstract
Paravertebral block and epidural block are frequently employed for post-thoracotomy pain relief. It is not clear which postoperative analgesia method is effective for the chronic pain after the postoperative long term progress. Our hypothesis was that paravertebral block would be more effective than epidural block for chronic pain 1.5-2 years after thoracotomy. A cohort study investigating postoperative pain was performed in lung cancer patients undergoing thoracotomy between the ages of 20-80 year-old, employed for another randomized controlled trial. In previously study, the patients were randomly allocated into either the epidural block or paravertebral block group (n = 36/group). Patients in each group received the respective block placement with continuous 0.2% ropivacaine infusion at 5 ml/h. The patients completed a telephone observational survey using the EQ-5D-5L at 1.5-2 years. Forty-eight patients, 23 in the epidural block group and 25 in the paravertebral block group, were included in the final analysis. Quality of life scores at 1.5-2 postoperative years was similar in both groups. Mean scores ± standard deviation and 95% confidence interval were 0.899 ± 0.081 (0.705-0.938) in the epidural block group and 0.905 ± 0.079 (0.713-0.938) in the paravertebral block group, respectively, p = 0.81. The incidence rate of chronic postsurgical pain was eight patients; four in the epidural block group (17.4%) and four in the paravertebral block group (16.0%). There was no difference in incidence rate of long-term chronic postsurgical pain at 1.5-2 years after thoracotomy between the both groups. Our result will be used for further study protocols.
Collapse
|
19
|
Effect of intensive insulin therapy on inflammatory response after cardiac surgery using bedside artificial pancreas: a propensity score-matched analysis. Artif Organs 2022. [PMID: 36219496 DOI: 10.1111/aor.14418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 09/03/2022] [Accepted: 09/29/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Perioperative hyperglycemia leads to poor postoperative clinical outcomes, including compromised immune function, cardiovascular events, and mortality. The optimal perioperative blood glucose levels during cardiac surgery remain unclear. A closed-loop glycemic control system (artificial pancreas, target blood glucose range:120-150 mg/dL) prevents postoperative inflammatory response more effectively than conventional insulin therapy (< 200 mg/dL). However, the clinical effects of intensive insulin therapy with strict glycemic control (80-110 mg/dL) are controversial. This study aimed to determine whether intensive insulin therapy would further suppress postoperative inflammatory reactions. METHODS This study analyzed 262 patients who underwent cardiovascular surgery with cardiopulmonary bypass. The patients were divided into two groups according to their target blood glucose range: 80-110 mg/dL and 120-150 mg/dL. The primary outcome was the difference in the C-reactive protein levels between the two groups. RESULTS Propensity score matching resulted in 95 patients in each group based on their covariates. There was no difference in the postoperative maximum C-reactive protein levels between the two groups (14.81 ± 5.93 mg/dL vs. 14.34 ± 5.52 mg/dL; P = 0.571) following propensity score matching. Hypoglycemia did not occur during intensive insulin therapy. CONCLUSIONS Intensive insulin therapy following cardiac surgery with cardiopulmonary bypass did not demonstrate significant advantages in the suppression of postoperative inflammatory reactions compared to that with mild glycemic control. However, intensive insulin therapy using an artificial pancreas was found to be safe, with no hypoglycemic events.
Collapse
|
20
|
Observation of Spectral Structures in the Flux of Cosmic-Ray Protons from 50 GeV to 60 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 129:101102. [PMID: 36112450 DOI: 10.1103/physrevlett.129.101102] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/19/2022] [Accepted: 08/03/2022] [Indexed: 06/15/2023]
Abstract
A precise measurement of the cosmic-ray proton spectrum with the Calorimetric Electron Telescope (CALET) is presented in the energy interval from 50 GeV to 60 TeV, and the observation of a softening of the spectrum above 10 TeV is reported. The analysis is based on the data collected during ∼6.2 years of smooth operations aboard the International Space Station and covers a broader energy range with respect to the previous proton flux measurement by CALET, with an increase of the available statistics by a factor of ∼2.2. Above a few hundred GeV we confirm our previous observation of a progressive spectral hardening with a higher significance (more than 20 sigma). In the multi-TeV region we observe a second spectral feature with a softening around 10 TeV and a spectral index change from -2.6 to -2.9 consistently, within the errors, with the shape of the spectrum reported by DAMPE. We apply a simultaneous fit of the proton differential spectrum which well reproduces the gradual change of the spectral index encompassing the lower energy power-law regime and the two spectral features observed at higher energies.
Collapse
|
21
|
1076P Cancer cachexia associated with gut microbiota and clinical outcomes of patients with non-small cell lung cancer amenable to immunotherapy. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.07.1202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
22
|
Chemical and Chemo-Enzymatic Syntheses of Glycans Containing Ribitol Phosphate Scaffolding of Matriglycan. ACS Chem Biol 2022; 17:1513-1523. [PMID: 35670527 DOI: 10.1021/acschembio.2c00181] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Ribitol phosphate modifications to the core M3 O-mannosyl glycan are important for the functional maturation of α-dystroglycan. Three sequentially extended partial structures of the core M3 O-mannosyl glycan including a tandem ribitol phosphate were regio- and stereo-selectively synthesized: Rbo5P-3GalNAcβ, Rbo5P-1Rbo5P-3GalNAcβ, and Xylβ1-4Rbo5P-1Rbo5P-3GalNAcβ (Rbo5P, d-ribitol-5-phosphate; GalNAc, N-acetyl-d-galactosamine; Xyl, d-xylose). Rbo5P-3GalNAcβ with p-nitrophenyl at the aglycon part served as a substrate for ribitol phosphate transferase (FKRP, fukutin-related protein), and its product was glycosylated by the actions of a series of glycosyltransferases, namely, ribitol xylosyltransferase 1 (RXYLT1), β1,4-glucuronyltransferase 1 (B4GAT1), and like-acetyl-glucosaminyltransferase (LARGE). Rbo5P-3GalNAcβ equipped with an alkyne-type aglycon was also active for FKRP. The molecular information obtained on FKRP suggests that Rbo5P-3GalNAcβ derivatives are the minimal units required as the acceptor glycan for Rbo5P transfer and may serve as a precursor for the elongation of the core M3 O-mannosyl glycan.
Collapse
|
23
|
SO-19 Biomarker analysis using plasma angiogenesis factors in the TRUSTY study: A randomized phase 2/3 study of trifluridine/tipiracil plus bevacizumab as second-line treatment for metastatic colorectal cancer. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.04.418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
24
|
Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 128:131103. [PMID: 35426700 DOI: 10.1103/physrevlett.128.131103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/03/2022] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ∼3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [1O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).PRLTAO0031-900710.1103/PhysRevLett.126.241101], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51±0.07.
Collapse
|
25
|
Safe sedation management using volatile anesthetics during cardiopulmonary bypass. J Anesth 2022; 36:287-293. [PMID: 35267071 DOI: 10.1007/s00540-022-03054-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/24/2022] [Indexed: 11/27/2022]
Abstract
Several pieces of evidence suggest that volatile anesthetics (VAs), which were originally used as sedatives, have myocardial protective effects against cardiac ischemia-reperfusion injury. In Europe and the United States, the use of VAs during cardiopulmonary bypass (CPB) is widespread, as 2019 European Association for Cardio-Thoracic Surgery (EACTS)/European Association of Cardiothoracic Anaesthesiology/European Board of Cardiovascular Perfusion, 2011 American College of Cardiology/American Heart Association, and 2017 EACTS guidelines recommend their use in cardiovascular surgery, based on their potential myocardial protective effects. In other countries, including Japan, the use of VAs is gradually increasing. Therefore, it is important to be aware of the risks and possible adverse events associated with VA use during CPB to ensure safe sedation management. Herein, we describe in detail issues such as intraoperative awareness, air pollution, and damage to oxygenators due to VA use and propose precautions.
Collapse
|
26
|
The equilibrated blood sevoflurane concentrations show a rapid decrease after switching from ventilation for the human lung to cardiopulmonary bypass. NAGOYA JOURNAL OF MEDICAL SCIENCE 2022; 84:163-168. [PMID: 35392015 PMCID: PMC8971030 DOI: 10.18999/nagjms.84.1.163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 07/12/2021] [Indexed: 11/08/2022]
Abstract
Volatile anesthetics (VAs) protect myocardial cells during cardiovascular surgeries, including cardiopulmonary bypass (CPB). In CPB, blood is gradually transferred from the body to a CPB unit until the target cardiac index is achieved, following which human lung (HL) ventilation is stopped. This pilot study aimed to evaluate changes in the blood sevoflurane concentrations 5 min after the start of CPB when its delivery to the oxygenator began after HL ventilation with sevoflurane was completed. Six patients were recruited and participated in this study. For each patient, the equilibrated blood sample, collected 20 min after starting the delivery of 1.7% sevoflurane (HL group), and another blood sample, collected 5 min after starting the CPB, were analyzed using gas chromatography equipped with a flame ionization detector. The mean (± standard deviation) sevoflurane concentrations in the HL and 5 min after starting CPB groups were 58.6 ± 4.7 and 14.5 ± 5.0 μg/ml, respectively (P < 0.01). In conclusion, the equilibrated blood sevoflurane concentrations showed a rapid decrease when switching from sevoflurane ventilation for the HL to CPB unless it was introduced to the oxygenator until completion of the switch.
Collapse
|
27
|
Autotransfusion of vaginally shed blood as a novel therapy in obstetric hemorrhage: A case series. Transfusion 2022; 62:613-620. [PMID: 34997764 DOI: 10.1111/trf.16794] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 12/08/2021] [Accepted: 12/23/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To report maternal outcomes in a cohort of women who received autotransfusion of vaginally shed blood and to describe the feasibility of blood collection and cell salvage processing at the time of vaginal hemorrhage. STUDY DESIGN AND METHODS We conducted a retrospective case series of patients who received autotransfusion of vaginally shed blood at the time of obstetric hemorrhage from January 2014 to August 2020. Maternal data and cell salvage utilization characteristics were abstracted from the electronic medical record. RESULTS Sixty-four cases were identified in which autotransfusion of vaginally shed blood occurred during an obstetric hemorrhage. Median quantitative blood loss was 2175 ml (interquartile range 1500-2250 ml) with 89% of cases having a blood loss greater than 1000 ml. Patients on average received approximately 1.3 units of autologous blood product (384 ml, interquartile range 244-520 ml) and no direct adverse events were observed during transfusion. We observed heterogeneity in autologous blood volume across all values of quantitative blood loss. The need for allogenic blood transfusion was common and occurred in 72% of all cases (N = 46). There were no documented cases of maternal sepsis or severe infectious morbidity. CONCLUSION In 64 cases where autotransfusion of vaginally shed blood occurred, autotransfusion was well tolerated. Heterogeneity in autologous blood volume collection likely represents the lack of standardized protocols for blood collection in the delivery room. Autotransfusion of vaginally shed blood is a feasible and reasonable technique to employ during severe obstetric hemorrhage.
Collapse
|
28
|
Synthesis of the matriglycan hexasaccharide, -3Xylα1-3GlcAβ1-trimer and its interaction with laminin. Org Biomol Chem 2022; 20:8489-8500. [DOI: 10.1039/d2ob01388f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Matriglycan hexasaccharide (-3Xylα1-3GlcAβ1)3-O(C2H4O)3CH2CCH and the biotin conjugate was synthesized. The hexasaccharide showed good interaction with laminin-G-like domains 4 and 5 of laminin-α2 using saturation transfer difference-NMR and bio-layer interferometry.
Collapse
|
29
|
Heparin concentration in cell salvage during heparinization: a pilot study. NAGOYA JOURNAL OF MEDICAL SCIENCE 2021; 82:449-455. [PMID: 33132429 PMCID: PMC7548247 DOI: 10.18999/nagjms.82.3.449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Cell salvage is frequently used to avoid unnecessary allogeneic blood transfusions, which results in a reduction in blood transfusion volume and cost. The aspirated blood is washed with normal saline and centrifuged to recover only blood cells, salvaged blood is then made. In cardiovascular surgery, heparin is used to maintain activated clotting time over 400 seconds. Some practitioners believe that heparin remains in the salvaged blood. Therefore, we hypothesized that salvaged blood during cardiovascular surgery includes heparin. A pilot study was conducted to evaluate our hypothesis using three different salvage systems. This study was a prospective, observational, pilot study, with patients aged 20-85 years old who were scheduled for cardiovascular surgery from May 2018 to October 2018. The intent of this study was to evaluate whether salvaged blood with three different devices includes large enough quantities of heparin to influence activated clotting time in cardiovascular surgery. Between May and October 2018, 12 samples during heparinization were collected, and 12 samples of salvaged blood from 3 devices were collected after administrating protamine. The heparin concentration of the 24 samples was measured. All heparin concentrations in salvage blood sample from two devices was below the limit of measurement (0.10 IU/mL). Slightly measurable heparin was detected in salvaged blood sample from one device (mean 0.15 IU/mL). Salvaged blood during cardiovascular surgery intervention does not contain enough heparin to influence activated clotting time.
Collapse
|
30
|
Certified registered nurse anesthetist and anesthesiologist assistant education programs in the United States. NAGOYA JOURNAL OF MEDICAL SCIENCE 2021; 83:609-626. [PMID: 34552293 PMCID: PMC8437993 DOI: 10.18999/nagjms.83.3.609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 11/30/2020] [Indexed: 11/30/2022]
Abstract
In Japan, a relative shortage of practicing anesthesiologists continues to be a national issue. To address this issue, some Japanese medical institutions have started developing curriculums to train non-physician perioperative anesthesia personnel, including nurse practitioners and perianesthesia nurses. We urgently need to establish a national standard for the education programs that train these extended non-physician anesthesia care providers. A certified registered nurse anesthetist educational program at a large academic medical center in the United States is described in detail as a reference. Highly systematic educational programs using simulation, didactics, and full clinical subspecialty rotations are ideal if not easily achievable in many current training institutions in Japan. Anesthesia assistant education programs in the United States can be used as an additional reference to create a national educational program in Japan.
Collapse
|
31
|
Handling and Mechanical Properties of Low-viscosity Bulk-fill Resin Composites. Oper Dent 2021; 46:E185-E198. [PMID: 35486512 DOI: 10.2341/20-253-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/23/2021] [Indexed: 11/23/2022]
Abstract
This study aimed to evaluate the filler contents (FCs), flexural properties, depth of cure (DOC), wear resistance, and handling properties of different low-viscosity bulk-fill resin composites (LVBRCs) and to determine the correlations between the tested parameters. Six LVBRCs, Beautifil-Bulk (BBF), Bulk Base Hard (BBH), Bulk Base Medium (BBM), Filtek Bulk-Fill Flowable Restorative (FBF), G-ænial Bulk Injectable (GBI), and SDR flow+ Bulk-Fill Flowable (SDR) were used. The DOC and flexural property tests were conducted according to the ISO 4049 specifications. The flexural strength, elastic modulus, and resilience were determined in 12 specimens that were obtained from each of the 6 materials. Sliding-impact-wear testing was conducted by evaluating the wear facets of the specimens using a noncontact profilometer and by confocal laser scanning microscopy. The handling properties of the LVBRC was assessed via extrusion force and thread formation measurements. The DOC for the majority of the LVBRCs was approximately 4 mm. Although the FCs and mechanical properties were material dependent, some LVBRCs exhibited excellent flexural properties and wear resistance. The LVBRCs demonstrated a wide range of extrusion force and thread formation. Regarding the correlations between the tested parameters, extremely strong negative and positive correlations were observed for the DOC versus extrusion force, flexural strength versus elastic modulus, maximum depth versus volume loss, and maximum depth versus thread formation. In addition, strong correlations between FCs and DOC, resilience, wear resistance, and extrusion force were observed.
Collapse
|
32
|
Measurement of the Iron Spectrum in Cosmic Rays from 10 GeV/n to 2.0 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2021; 126:241101. [PMID: 34213922 DOI: 10.1103/physrevlett.126.241101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/24/2021] [Accepted: 04/12/2021] [Indexed: 06/13/2023]
Abstract
The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this Letter a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10 GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/n our present data are compatible with a single power law with spectral index -2.60±0.03.
Collapse
|
33
|
Nivolumab with carboplatin, paclitaxel, and bevacizumab for first-line treatment of advanced nonsquamous non-small-cell lung cancer. Ann Oncol 2021; 32:1137-1147. [PMID: 34139272 DOI: 10.1016/j.annonc.2021.06.004] [Citation(s) in RCA: 83] [Impact Index Per Article: 27.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 05/26/2021] [Accepted: 06/10/2021] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND This international, randomized, double-blind phase III study (ONO-4538-52/TASUKI-52) evaluated nivolumab with bevacizumab and cytotoxic chemotherapy as first-line treatment for nonsquamous non-small-cell lung cancer (NSCLC). PATIENTS AND METHODS Between June 2017 and July 2019, this study enrolled treatment-naïve patients with stage IIIB/IV or recurrent nonsquamous NSCLC without sensitizing EGFR, ALK, or ROS1 alterations. They were randomly assigned in a 1 : 1 ratio to receive nivolumab or placebo in combination with carboplatin, paclitaxel, and bevacizumab every 3 weeks for up to six cycles, followed by nivolumab/placebo with bevacizumab until progressive disease or unacceptable toxicity. The primary endpoint was progression-free survival (PFS) assessed by an independent radiology review committee (IRRC). RESULTS Overall, 550 patients from Japan, Korea, and Taiwan were randomized; of these patients, 273 and 275 received the nivolumab and placebo combinations, respectively. In the present preplanned interim analysis with a median follow up of 13.7 months, the IRRC-assessed median PFS was significantly longer in the nivolumab arm than in the placebo arm (12.1 versus 8.1 months; hazard ratio 0.56; 96.4% confidence interval 0.43-0.71; P < 0.0001). The PFS benefit was observed across all patients with any programmed death-ligand 1 (PD-L1) expression levels including PD-L1-negative patients. The IRRC-assessed objective response rates were 61.5% and 50.5% in the nivolumab and placebo arms, respectively. The incidence of treatment-related adverse events of grade 3 or 4 was comparable between the two arms; treatment-related adverse events leading to death were observed in five and four patients in the nivolumab and placebo arms, respectively. CONCLUSION The TASUKI-52 regimen should be considered a viable new treatment strategy for treatment-naïve patients with advanced nonsquamous NSCLC.
Collapse
|
34
|
Comparison between the effects of normal saline with and without heparin for the prevention and management of arterial catheter occlusion: a triple-blinded randomized trial. J Anesth 2021; 35:536-542. [PMID: 34043108 DOI: 10.1007/s00540-021-02949-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 05/22/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE We aimed to compare the effects of saline with and without heparin on the catheter-occlusion rate and coagulation-related blood test results for the management of arterial catheters among patients admitted to a short-term intensive care unit postoperatively. METHODS This prospective, triple-blinded, randomized controlled study recruited patients aged 20-90 years scheduled to undergo radial arterial catheter insertion and postoperative intensive care unit admission between February and August 2019. Patients were randomly allocated to two groups (1:1 ratio) depending on the use of heparin: study (normal saline with heparin, 3000 units to 500 ml of normal saline) and control (normal saline without heparin) groups with arterial catheters. The allocated management method was employed immediately after intensive care unit admission. Occlusion assessment (every 12 h), arterial blood gas tests (every 6 h), and blood sample collection (every 24 h) were performed. The occlusion of arterial catheter was assessed using occlusion rate, and blood test results were assessed using a linear mixed model. RESULTS There were 147 patients in the arterial catheter groups. There were no significant differences in occlusion rates and changes in platelet counts and activated partial thromboplastin time between the groups with arterial (p = 0.98, 0.16, and 0.32, respectively) catheters during the first 6 days after intensive care unit admission. CONCLUSION Normal saline with and without heparin showed similar efficiency for both the prevention of occlusion and the results of coagulation.
Collapse
|
35
|
|
36
|
JM-1232(-) and propofol, a new combination of hypnotics with short-acting and non-cumulative preferable properties. Exp Anim 2021; 70:101-107. [PMID: 33071272 PMCID: PMC7887627 DOI: 10.1538/expanim.20-0071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 09/10/2020] [Indexed: 10/31/2022] Open
Abstract
Drug interactions are significant in anesthesiology because drug combinations can potentially possess novel properties. The pharmacological advantages of a new combination of the benzodiazepine receptor agonist JM-1232(-) and propofol were investigated in mice. Male adult mice were administered JM-1232(-) or propofol or combinations of the two drugs intravenously. Loss of the righting reflex was evaluated as achieving hypnosis, and the time until recovery of the reflex was measured as hypnosis time. After determining the ED50, doses double and triple the ED50 of propofol were injected with JM-1232(-) to compare hypnosis time. The injections were repeated four times, and the hypnosis times were compared. Flumazenil was administered separately immediately after the last dose was injected. The ED50 values ([95% confidence interval]) for hypnosis were 3.76 [3.36-4.10] for JM-1232(-) and 9.88 [8.03-11.58] mg kg-1 for propofol. Co-administration of 0.5 and 1 mg kg-1 JM-1232(-) reduced the ED50 values of propofol to 1.76 [1.21-2.51] and 1.00 [0.46-1.86] mg kg-1, respectively. The drug combination for hypnosis produced a supra-additive interaction. Hypnosis time was significantly shorter in the groups given the mixtures compared to each hypnotic administered alone. After repeated injections, hypnosis time with the mixtures showed smaller prolongation than that with the hypnotic alone. Flumazenil completely restored the recovery time after anesthesia. The combination of JM-1232(-) and propofol showed a supra-additive interaction, and the reduced hypnotic dose contributed to a faster recovery even after multiple injections.
Collapse
|
37
|
Pregabalin-induced hypoglycemia in a dialysis patient. Korean J Anesthesiol 2021; 74:87. [PMID: 33535729 PMCID: PMC7862940 DOI: 10.4097/kja.20368.e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
38
|
550 Autotransfusion of vaginally shed blood during obstetric hemorrhage: a matched cohort atudy. Am J Obstet Gynecol 2021. [DOI: 10.1016/j.ajog.2020.12.571] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
39
|
Fatal airway obstruction due to a ball-valve clot with identical signs of tension pneumothorax. Acute Crit Care 2021; 35:298-301. [PMID: 33423441 PMCID: PMC7808852 DOI: 10.4266/acc.2019.00570] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Accepted: 11/01/2019] [Indexed: 12/02/2022] Open
Abstract
Endo-tracheal tube obstruction due to an extensive blood clot is a recognized but very rare complication. A ball-valve obstruction in the airway could function as a check valve for the lung and thorax, resulting in tension pneumothorax-like abnormalities. A 47-year-old female patient had undergone implantation of a left ventricular assist device 3 weeks prior. On post-operative day 17, planned thoracentesis was performed for drainage of a pleural effusion. Despite the drainage, the patient’s oxygenation did not improve, and emergency tracheal intubation was conducted. Subsequent computed tomography revealed bilateral pneumothorax. Two days later, the patient’s trachea was extubated without complication, and a mini-tracheostomy tube was placed. Three hours later, reintubation was conducted due to progressive tachypnea. Although successful intubation was confirmed, ventilation became increasingly difficult and finally impossible. Marked increase in pulmonary artery and central venous pressures suggested progression of the previous tension pneumothorax. After emergency extracorporeal membrane oxygenation was initiated, fiberoptic bronchoscopy revealed the presence of a massive clot and ball-valve obstruction of the endotracheal tube. Two weeks later, the patient died due to severe hypoxic brain damage. Diagnosis of ball valve clot is not simple, but intensivists should consider this rare complication.
Collapse
|
40
|
Reply to the letter. J Anesth 2021; 35:164. [PMID: 33416993 DOI: 10.1007/s00540-020-02892-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 12/18/2020] [Indexed: 11/26/2022]
|
41
|
Direct Measurement of the Cosmic-Ray Carbon and Oxygen Spectra from 10 GeV/n to 2.2 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2020; 125:251102. [PMID: 33416351 DOI: 10.1103/physrevlett.125.251102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/01/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope on the International Space Station from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV/n to 2.2 TeV/n with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of ∼0.15 around 200 GeV/n established with a significance >3σ. They have the same energy dependence with a constant C/O flux ratio 0.911±0.006 above 25 GeV/n. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.
Collapse
|
42
|
396P Efficacy and safety of S-1 in elderly patients with advanced non-small cell lung cancer previously treated with platinum-based chemotherapy: A subgroup analysis of the EAST-LC. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.10.390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
43
|
|
44
|
Stereo- and Regioselective Synthesis of O-Mannosyl Glycan Containing Matriglycan and a Part of Tandem Ribitol Phosphate. J Org Chem 2020; 85:12935-12946. [PMID: 32930586 DOI: 10.1021/acs.joc.0c01569] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We herein successfully synthesized two pivotal structures of O-mannosyl glycan: (1) the matriglycan-repeating tetrasaccharide Xylα1-3GlcAβ1-3Xylα1-3GlcAβ and (2) the link between matriglycan and a part of tandem ribitol phosphate, Xylα1-3GlcAβ1-4Xylβ1-4Rbo, in a regio- and stereocontrolled manner. The disaccharide unit with the α-linkage of xylose was obtained by adopting the conformational fixation of the xylopyranoside ring and a specific solvation system of diastereoselective solubility.
Collapse
|
45
|
Aspiration of massive free air from a large bore intravenous catheter sheath: A case report. Radiol Case Rep 2020; 15:1777-1780. [PMID: 32793316 PMCID: PMC7406973 DOI: 10.1016/j.radcr.2020.07.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 07/09/2020] [Accepted: 07/10/2020] [Indexed: 11/16/2022] Open
Abstract
We firstly experienced a rare case demonstrating that massive volume of free air was aspirated from a large bore intravenous catheter sheath of the pulmonary arterial catheter during placement. A 44-year-old male patient underwent the emergency induction of anesthesia for transplantation of liver donated by the brain death subject. After the induction, the central venous and pulmonary artery catheter placement was conducted. The aspiration of venous blood confirmed the intravascular insertion, but massive free air was aspirated when we advanced the sheath proximally. A perforation of subclavian vein and subsequent pneumothorax was strongly suspected. The emergency computed tomography revealed no sign of pneumothorax, pneumomediastinum nor extravasation. The operation was undergone with intensive monitoring and no further adverse complication was observed. The postoperative medical inquiry concluded that the massive free air was not aspirated from extravascular space, for example, thorax or mediastinum through the tip of the sheath, but from the proximal main port of the sheath. When the tip of sheath is occluded by the migration into small vessels, the large negative pressure through side port might easily aspirate the air through the 1-way valve of the main proximal port. Physicians should keep in mind of the structure of the catheter sheath.
Collapse
|
46
|
REGISTRIES, CARE, QUALITY OF LIFE, MANAGEMENT OF NMD. Neuromuscul Disord 2020. [DOI: 10.1016/j.nmd.2020.08.342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
47
|
LBA54 Randomized phase III trial of nivolumab in combination with carboplatin, paclitaxel, and bevacizumab as first-line treatment for patients with advanced or recurrent non-squamous NSCLC. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.08.2287] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
48
|
Desflurane and sevoflurane concentrations in blood passing through the oxygenator during cardiopulmonary bypass: a randomized prospective pilot study. J Anesth 2020; 34:904-911. [PMID: 32851513 PMCID: PMC7449527 DOI: 10.1007/s00540-020-02844-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Accepted: 08/13/2020] [Indexed: 12/13/2022]
Abstract
Purpose Volatile anesthetics (VAs) protect myocardial cells in cardiovascular surgery. A recent clinical trial of cardiopulmonary bypass (CPB) surgery reported no significant difference in mortality rates between the use of VAs and total intravenous anesthetics at 1 year postoperatively. However, oxygenator function may affect the VA pharmacokinetics. Thus, we measured the VA blood concentrations during CPB in patients managed with four different microporous polypropylene hollow fiber membrane oxygenators. Methods Twenty-four patients scheduled for elective CPB were randomly allocated to one of the two VA groups (desflurane and sevoflurane groups) and, then, randomly divided into one of four oxygenator groups: Terumo, LivaNova, Medtronic, and Senko (n = 3). Additionally, in each VA group, three patients were randomly selected and redundantly allocated to the human lung group (for control blood VA concentration without oxygenator). Blood samples collected 20 min after starting 6.0 vol% desflurane or 1.7 vol% sevoflurane were analyzed using gas chromatography. Oxygenator-related complications and structural changes in the membrane surface of each oxygenator after surgery were evaluated. Results The mean (standard deviation) concentrations of desflurane and sevoflurane in the human lung were 182.4 (23.2) and 54.0 (9.6) μg/ml, respectively; not significantly different from those in the four oxygenator groups. No oxygenator-related complications occurred. Structural changes in membrane fibers did not occur after clinical use, except for difficulty in image acquisition with Senko products. Conclusion Our results demonstrated that the blood concentrations of desflurane and sevoflurane passing through oxygenators used during CPB were similar to those in the human lung control. Electronic supplementary material The online version of this article (10.1007/s00540-020-02844-1) contains supplementary material, which is available to authorized users.
Collapse
|
49
|
Pregabalin-induced hypoglycemia in a dialysis patient. Korean J Anesthesiol 2020; 73:570-571. [PMID: 32721983 PMCID: PMC7714625 DOI: 10.4097/kja.20368] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Accepted: 07/21/2020] [Indexed: 11/29/2022] Open
|
50
|
Short communication: Detection of mastication speed during rumination in cattle using 3-axis, neck-mounted accelerometers and fast Fourier transfer algorithm. J Dairy Sci 2020; 103:7180-7187. [PMID: 32505412 DOI: 10.3168/jds.2019-17611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Accepted: 03/24/2020] [Indexed: 11/19/2022]
Abstract
There have been limited reports on mastication speed during cattle rumination. The objective of this study was to establish a method to detect mastication speed based on data obtained during rumination through the use of a 3-axis accelerometer attached to the neck. A 3-axis accelerometer was attached to 6 dry Holstein cattle. When rumination behavior was observed, the accelerometer and the high-speed camera simultaneously recorded acceleration at the neck and moving image of the head movement. Based on the number of mastication movements recorded on video, mastication speed A was calculated. Data obtained from the 3-axis accelerometer were analyzed with fast Fourier transfer algorithm and identified as mastication speed B. The vibration of the neck recorded in the accelerometer during rumination was considered as mastication movement. Using Bland-Altman plot analysis, the mean difference between mastication speed A and mastication speed B was 0.041 s/bite, and the 95% limits of agreement ranged from -0.080 to 0.161. Since mastication movement occurred periodically, it was possible to detect the movement using spectrum analysis, as mastication speed B. Although there were some differences between calculated speeds and speeds obtained from spectrum analysis, there was clinical compatibility between mastication speed A and B. This study showed the feasibility of establishing a detection method for mastication speed during rumination, which might provide a basic procedure for studying the purpose of mastication and the variable factors involved.
Collapse
|