1
|
Genetic Mapping and Characterization of Verticillium Wilt Resistance in a Recombinant Inbred Population of Upland Cotton. Int J Mol Sci 2024; 25:2439. [PMID: 38397116 PMCID: PMC10889826 DOI: 10.3390/ijms25042439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/13/2024] [Accepted: 02/15/2024] [Indexed: 02/25/2024] Open
Abstract
Verticillium wilt (VW) is an important and widespread disease of cotton and once established is long-lived and difficult to manage. In Australia, the non-defoliating pathotype of Verticillium dahliae is the most common, and extremely virulent. Breeding cotton varieties with increased VW resistance is the most economical and effective method of controlling this disease and is greatly aided by understanding the genetics of resistance. This study aimed to investigate VW resistance in 240 F7 recombinant inbred lines (RIL) derived from a cross between MCU-5, which has good resistance, and Siokra 1-4, which is susceptible. Using a controlled environment bioassay, we found that resistance based on plant survival or shoot biomass was complex but with major contributions from chromosomes D03 and D09, with genomic prediction analysis estimating a prediction accuracy of 0.73 based on survival scores compared to 0.36 for shoot biomass. Transcriptome analysis of MCU-5 and Siokra 1-4 roots uninfected or infected with V. dahliae revealed that the two cultivars displayed very different root transcriptomes and responded differently to V. dahliae infection. Ninety-nine differentially expressed genes were located in the two mapped resistance regions and so are potential candidates for further identifying the genes responsible for VW resistance.
Collapse
|
2
|
Dissecting the major genetic components underlying cotton lint development. Genetics 2024; 226:iyad219. [PMID: 38147531 PMCID: PMC10847716 DOI: 10.1093/genetics/iyad219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 10/05/2023] [Accepted: 12/07/2023] [Indexed: 12/28/2023] Open
Abstract
Numerous genetic loci and several functionally characterized genes have been linked to determination of lint percentage (lint%), one of the most important cotton yield components, but we still know little about the major genetic components underlying lint%. Here, we first linked the genetic loci containing MYB25-like_At and HD1_At to the fiberless seed trait of 'SL1-7-1' and found that MYB25-like_At and HD1_At were very lowly expressed in 'SL1-7-1' ovules during fiber initiation. We then dissected the genetic components involved in determination of lint% using segregating populations derived from crosses of fuzzless mutants and intermediate segregants with different lint%, which not only confirmed the HD1_At locus but identified the HD1_Dt locus as being the major genetic components contributing to fiber initiation and lint%. The segregating populations also allowed us to evaluate the relative contributions of MYB25-like_At, MYB25-like_Dt, HD1_At, and HD1_Dt to lint%. Haplotype analysis of an Upland cotton (Gossypium hirsutum) population with 723 accessions (including 81 fuzzless seed accessions) showed that lint% of the accessions with the LP allele (higher lint%) at MYB25-like_At, MYB25-like_Dt, or HD1_At was significantly higher than that with the lp allele (lower lint%). The lint% of the Upland cotton accessions with 3 or 4 LP alleles at MYB25-like and HD1 was significantly higher than that with 2 LP alleles. The results prompted us to propose a strategy for breeding high-yielding cotton varieties, i.e. pyramiding the LP alleles of MYB25-like and HD1 with new lint% LP alleles without negative impact on seed size and fiber quality.
Collapse
|
3
|
Ultrahigh resolution whole body photon counting computed tomography as a novel versatile tool for translational research from mouse to man. Z Med Phys 2022:S0939-3889(22)00066-6. [PMID: 35868888 DOI: 10.1016/j.zemedi.2022.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 06/18/2022] [Accepted: 06/19/2022] [Indexed: 11/19/2022]
Abstract
X-ray computed tomography (CT) is a cardinal tool in clinical practice. It provides cross-sectional images within seconds. The recent introduction of clinical photon-counting CT allowed for an increase in spatial resolution by more than a factor of two resulting in a pixel size in the center of rotation of about 150 µm. This level of spatial resolution is in the order of dedicated preclinical micro-CT systems. However so far, the need for different dedicated clinical and preclinical systems often hinders the rapid translation of early research results to applications in men. This drawback might be overcome by ultra-high resolution (UHR) clinical photon-counting CT unifying preclinical and clinical research capabilities in a single machine. Herein, the prototype of a clinical UHR PCD CT (SOMATOM CounT, Siemens Healthineers, Forchheim, Germany) was used. The system comprises a conventional energy-integrating detector (EID) and a novel photon-counting detector (PCD). While the EID provides a pixel size of 0.6 mm in the centre of rotation, the PCD provides a pixel size of 0.25 mm. Additionally, it provides a quantification of photon energies by sorting them into up to four distinct energy bins. This acquisition of multi-energy data allows for a multitude of applications, e.g. pseudo-monochromatic imaging. In particular, we examine the relation between spatial resolution, image noise and administered radiation dose for a multitude of use-cases. These cases include ultra-high resolution and multi-energy acquisitions of mice administered with a prototype bismuth-based contrast agent (nanoPET Pharma, Berlin, Germany) as well as larger animals and actual patients. The clinical EID provides a spatial resolution of about 9 lp/cm (modulation transfer function at 10%, MTF10%) while UHR allows for the acquisition of images with up to 16 lp/cm allowing for the visualization of all relevant anatomical structures in preclinical and clinical specimen. The spectral capabilities of the system enable a variety of applications previously not available in preclinical research such as pseudo-monochromatic images. Clinical ultra-high resolution photon-counting CT has the potential to unify preclinical and clinical research on a single system enabling versatile imaging of specimens and individuals ranging from mice to man.
Collapse
|
4
|
Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT. Eur Radiol 2021; 31:7664-7673. [PMID: 33783572 PMCID: PMC8452563 DOI: 10.1007/s00330-021-07821-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 02/19/2021] [Indexed: 01/01/2023]
Abstract
Objectives Virtual non-calcium (VNCa) images could improve assessment of plasma cell dyscrasias by enhancing visibility of bone marrow. Thus, VNCa images from dual-layer spectral CT (DLCT) were evaluated at different calcium suppression (CaSupp) indices, correlating results with apparent diffusion coefficient (ADC) values from MRI. Methods Thirty-two patients with initial clinical diagnosis of a plasma cell dyscrasia before any chemotherapeutic treatment, who had undergone whole-body low-dose DLCT and MRI within 2 months, were retrospectively enrolled. VNCa images with CaSupp indices ranging from 25 to 95 in steps of 10, conventional CT images, and ADC maps were quantitatively analyzed using region-of-interests in the vertebral bodies C7, T12, L1-L5, and the iliac bone. Independent two-sample t-test, Wilcoxon-signed-rank test, Pearson’s correlation, and ROC analysis were performed. Results Eighteen patients had a non-diffuse, 14 a diffuse infiltration in conventional MRI. A significant difference between diffuse and non-diffuse infiltration was shown for VNCa-CT with CaSupp indices from 55 to 95, for conventional CT, and for ADC (each p < 0.0001). Significant quantitative correlation between VNCa-CT and MRI could be found with strongest correlation at CaSupp index 65 for L3 (r = 0.68, p < 0.0001) and averaged L1-L5 (r = 0.66, p < 0.0001). The optimum CT number cut-off point for differentiation between diffuse and non-diffuse infiltration at CaSupp index 65 for averaged L1-L5 was −1.6 HU (sensitivity 78.6%, specificity 75.0%). Conclusion Measurements in VNCa-CT showed the highest correlation with ADC at CaSupp index 65. VNCa technique may prove useful for evaluation of bone marrow infiltration if MRI is not feasible. Key Points • VNCa-CT images can support the evaluation of bone marrow infiltration in plasma cell dyscrasias. • VNCa measurements of vertebral bodies show significant correlation with ADC in MRI. • Averaging L1-L5 at CaSupp index 65 allowed quantitative detection of infiltration comparable to MRI ADC.
Collapse
|
5
|
Genetic mapping and transcriptomic characterization of a new fuzzless-tufted cottonseed mutant. G3-GENES GENOMES GENETICS 2021; 11:1-14. [PMID: 33704434 PMCID: PMC8022719 DOI: 10.1093/g3journal/jkaa042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 12/07/2020] [Indexed: 11/13/2022]
Abstract
Fiber mutants are unique and valuable resources for understanding the genetic and molecular mechanisms controlling initiation and development of cotton fibers that are extremely elongated single epidermal cells protruding from the seed coat of cottonseeds. In this study, we reported a new fuzzless-tufted cotton mutant (Gossypium hirsutum) and showed that fuzzless-tufted near-isogenic lines (NILs) had similar agronomic traits and a higher ginning efficiency compared to their recurrent parents with normal fuzzy seeds. Genetic analysis revealed that the mutant phenotype is determined by a single incomplete dominant locus, designated N5. The mutation was fine mapped to an approximately 250-kb interval containing 33 annotated genes using a combination of bulked segregant sequencing, SNP chip genotyping, and fine mapping. Comparative transcriptomic analysis using 0-6 days post-anthesis (dpa) ovules from NILs segregating for the phenotypes of fuzzless-tufted (mutant) and normal fuzzy cottonseeds (wild-type) uncovered candidate genes responsible for the mutant phenotype. It also revealed that the flanking region of the N5 locus is enriched with differentially expressed genes (DEGs) between the mutant and wild-type. Several of those DEGs are members of the gene families with demonstrated roles in cell initiation and elongation, such as calcium-dependent protein kinase and expansin. The transcriptome landscape of the mutant was significantly reprogrammed in the 6 dpa ovules and, to a less extent, in the 0 dpa ovules, but not in the 2 and 4 dpa ovules. At both 0 and 6 dpa, the reprogrammed mutant transcriptome was mainly associated with cell wall modifications and transmembrane transportation, while transcription factor activity was significantly altered in the 6 dpa mutant ovules. These results imply a similar molecular basis for initiation of lint and fuzz fibers despite certain differences.
Collapse
|
6
|
Characterization and Genetic Mapping of Black Root Rot Resistance in Gossypium arboreum L. Int J Mol Sci 2021; 22:ijms22052642. [PMID: 33807984 PMCID: PMC7961528 DOI: 10.3390/ijms22052642] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/02/2021] [Accepted: 03/02/2021] [Indexed: 11/16/2022] Open
Abstract
Black root rot (BRR) is an economically important disease of cotton and other crops, especially in cooler regions with short growing seasons. Symptoms include black discoloration of the roots, reduced number of lateral roots and stunted or slow plant growth. The cultivated tetraploid Gossypium species are susceptible to BRR. Resistance to BRR was identified in G. arboreum accession BM13H and is associated with reduced and restricted hyphal growth and less sporulation. Transcriptome analysis indicates that BM13H responds to infection at early time points 2- and 3-days post-inoculation, but by day 5, few differentially expressed genes are observed between infected and uninfected roots. Inheritance of BM13H resistance to BRR was evaluated in an F6 recombinant inbred population and shows a single semi-dominant locus conferring resistance that was fine mapped to a region on chromosome 1, containing ten genes including five putative resistance-like genes.
Collapse
|
7
|
PO-1726: Clinical impact of spectral CT-based stopping power prediction for particle therapy planning. Radiother Oncol 2020. [DOI: 10.1016/s0167-8140(21)01744-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
8
|
Abstract
BACKGROUND Clinically, coronavirus disease 2019 (COVID-19) is associated with a wide range of symptoms, which can range from mild complaints of an upper respiratory infection to life-threatening hypoxic respiratory insufficiency and multiorgan failure. OBJECTIVE The initially identified pulmonary damage patterns, such as diffuse alveolar damage in acute lung failure, are accompanied by new findings that draw a more complex scenario. These include microvascular involvement and a wide range of associated pathologies of multiple organ systems. A back-scaling of microstructural vascular changes is possible via targeted correlation of pathological autopsy results with radiological imaging. MATERIAL AND METHODS Radiological and pathological correlation as well as microradiological imaging to investigate microvascular involvement in fatal COVID-19. RESULTS The cases of two COVID-19 patients are presented. Patient 1 showed a relative hypoperfusion in lung regions that did not have typical COVID-19 infiltrates; the targeted post-mortem correlation also showed subtle signs of microvascular damage even in these lung sections. Patient 2 showed both radiologically and pathologically advanced typical COVID-19 destruction of lung structures and the case illustrates the damage patterns of the blood-air barrier. The perfusion deficit of the intestinal wall shown in computed tomography of patient 2 could not ultimately clearly be microscopically attributed to intestinal microvascular damage. CONCLUSION In addition to microvascular thrombosis, our results indicate a functional pulmonary vasodysregulation as part of the pathophysiology during the vascular phase of COVID-19. The clinical relevance of autopsies and the integration of radiological imaging findings into histopathological injury patterns must be emphasized for a better understanding of COVID-19.
Collapse
|
9
|
Historical Datasets Support Genomic Selection Models for the Prediction of Cotton Fiber Quality Phenotypes Across Multiple Environments. G3 (BETHESDA, MD.) 2018; 8:1721-1732. [PMID: 29559536 PMCID: PMC5940163 DOI: 10.1534/g3.118.200140] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Accepted: 03/17/2018] [Indexed: 12/11/2022]
Abstract
Genomic selection (GS) has successfully been used in plant breeding to improve selection efficiency and reduce breeding time and cost. However, there has not been a study to evaluate GS prediction models that may be used for predicting cotton breeding lines across multiple environments. In this study, we evaluated the performance of Bayes Ridge Regression, BayesA, BayesB, BayesC and Reproducing Kernel Hilbert Spaces regression models. We then extended the single-site GS model to accommodate genotype × environment interaction (G×E) in order to assess the merits of multi- over single-environment models in a practical breeding and selection context in cotton, a crop for which this has not previously been evaluated. Our study was based on a population of 215 upland cotton (Gossypium hirsutum) breeding lines which were evaluated for fiber length and strength at multiple locations in Australia and genotyped with 13,330 single nucleotide polymorphic (SNP) markers. BayesB, which assumes unique variance for each marker and a proportion of markers to have large effects, while most other markers have zero effect, was the preferred model. GS accuracy for fiber length based on a single-site model varied across sites, ranging from 0.27 to 0.77 (mean = 0.38), while that of fiber strength ranged from 0.19 to 0.58 (mean = 0.35) using randomly selected sub-populations as the training population. Prediction accuracies from the M×E model were higher than those for single-site and across-site models, with an average accuracy of 0.71 and 0.59 for fiber length and strength, respectively. The use of the M×E model could therefore identify which breeding lines have effects that are stable across environments and which ones are responsible for G×E and so reduce the amount of phenotypic screening required in cotton breeding programs to identify adaptable genotypes.
Collapse
|
10
|
Genetic dissection of the fuzzless seed trait in Gossypium barbadense. JOURNAL OF EXPERIMENTAL BOTANY 2018; 69:997-1009. [PMID: 29351643 PMCID: PMC6018843 DOI: 10.1093/jxb/erx459] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 11/29/2017] [Indexed: 05/21/2023]
Abstract
Cotton fibres are single-celled trichomes arising from the epidermal cells of the seed coat and may be either long (lint) or very short (fuzz). The dominant fuzzless N1 of Gossypium hirsutum is a defective allele of the At-subgenome homoeolog of MYB25-like, but the genetic components underlying the recessive fuzzless trait from G. barbadense (Gb) are unknown. We have identified five genetic loci, including a major contributing locus containing MYB25-like_Dt, associated with Gb fuzzless seeds based on genotyping of fuzzy and fuzzless near isogenic lines (NILs) from an interspecies cross (G. barbadense × G. hirsutum). At 3 d post-anthesis when fuzz fibres are initiating, expression of MYB25-like_Dt was significantly lower in fuzzless NILs than in fuzzy seeded NILs, while higher MYB25-like_Dt expression was associated with more seed fuzz across different cotton genotypes. Phenotypic and genotypic analysis of MYB25-like homoeoalleles in cottons showing different fibre phenotypes and their crossing progeny indicated that both MYB25-like_At and MYB25-like_Dt are associated with lint development, and that fuzz development is mainly determined by the expression level of MYB25-like_Dt at ~3 d post-anthesis. Expression of Gb fuzzless seeds depends on genetic background and interactions amongst the multiple loci identified. MYB25-like_Dt is one of the best candidates for N2.
Collapse
|
11
|
Abstract
We propose a surface model of spin dephasing in lung tissue that includes both susceptibility and diffusion effects to provide a closed-form solution of the Bloch-Torrey equation on the alveolar surface. The nonlocal susceptibility effects of the model are validated against numerical simulations of spin dephasing in a realistic lung tissue geometry acquired from synchotron-based μCT data sets of mouse lung tissue, and against simulations in the well-known Wigner-Seitz model geometry. The free induction decay is obtained in dependence on microscopic tissue parameters and agrees very well with in vivo lung measurements at 1.5 Tesla to allow a quantification of the local mean alveolar radius. Our results are therefore potentially relevant for the clinical diagnosis and therapy of pulmonary diseases.
Collapse
|
12
|
Strahlenchemische Radikal-Reaktionen beim Übergang von der inhomogenen zur homogenen Verteilung der Reaktanten. Z PHYS CHEM 2017. [DOI: 10.1515/zpch-1978-25963] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
13
|
|
14
|
Stoßkinetische Berechnung von Geschwindigkeitskoeffizienten für bimolekulare Gasphasenreaktionen. Z PHYS CHEM 2017. [DOI: 10.1515/zpch-1980-26134] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
15
|
Statistische Geschwindigkeitskoeffizienten für Reaktionen zwischen Ionen und polaren Molekülen. Z PHYS CHEM 2017. [DOI: 10.1515/zpch-1983-26482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
16
|
Stoßkinetische Berechnung von Geschwindigkeitskonstanten für bimolekulare Gasphasenreaktionen. Z PHYS CHEM 2017. [DOI: 10.1515/zpch-1974-25560] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
17
|
Influence of Exposure Parameters and Iterative Reconstruction on MDCT-based Lung Densitometry – An ex vivo Phantom Study. Pneumologie 2016. [DOI: 10.1055/s-0036-1584640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
18
|
Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary Results. ROFO-FORTSCHR RONTG 2016; 188:559-65. [PMID: 27224576 DOI: 10.1055/s-0042-105765] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE To evaluate the diagnostic performance of dual energy (DE) perfusion-CT for the differentiation between postoperative soft-tissue formation and tumor recurrence in patients after potentially curative pancreatic cancer resection. MATERIAL AND METHODS 24 patients with postoperative soft-tissue formation in the conventional regular follow-up CT acquisition after pancreatic cancer resection with curative intent were included prospectively. They were examined with a 64-row dual-source CT using a dynamic sequence of 34 DE acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). Weighted average (linearly blended M0.5) 120kVp-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (see above) for estimating blood flow, permeability, and blood volume. Diagnosis was confirmed by histological study (n = 4) and by regular follow-up. RESULTS Final diagnosis was local recurrence of pancreatic cancer in 15 patients and unspecific postoperative tissue formation in 9 patients. The blood-flow values for recurrence tissue trended to be lower compared to postoperative tissue formation with 16.6 ml/100 ml/min and 24.7 ml/100 ml/min, respectively for weighted average 120kVp-equivalent image data, which was not significant (n.s.) (p = 0.06, significance level 0.05). Permeability- and blood-volume values were only slightly lower in recurrence tissue (n.s.). CONCLUSION DE perfusion-CT is feasible in patients after pancreatic cancer resection and a promising functional imaging technique. As only a trend for lower perfusion values in local recurrence compared to unspecific postoperative alterations was found, the perfusion differences are not yet sufficient to differentiate between malignancy and unspecific postoperative alterations for this new technique. Further studies and technical improvements are needed to generate reliable data for this clinically highly relevant differentiation. KEY POINTS • DE Perfusion CT is feasible in patients after pancreatic cancer resection.• While reliable differentiation of unspecific postoperative tissue formation from recurrent malignancy cannot be achieved yet, it is within reach.• DE Perfusion CT has the potential to overcome todays limitations of pure morphological diagnosis of recurrent pancreatic cancer. Citation Format: • Fritz F, Skornitzke S, Hackert T et al. Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary RESULTS. Fortschr Röntgenstr 2016; 188: 559 - 565.
Collapse
|
19
|
Quantitative Untersuchung linearer Modelle zur Approximation der CT-Perfusion auf der Grundlage von zum Zeitpunkt maximaler Gewebekontrastierung aufgenommenen Dual-Energy Jodkarten. ROFO-FORTSCHR RONTG 2016. [DOI: 10.1055/s-0036-1581278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
20
|
Untersuchung von Dual-energy (DE) Mischverhältnissen in Abhängigkeit der Strahlenexposition und des DE-Aufnahmemodus zur Erzeugung optimaler linearer DE-Mischbilder. ROFO-FORTSCHR RONTG 2016. [DOI: 10.1055/s-0036-1581231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
21
|
Integrated mapping and characterization of the gene underlying the okra leaf trait in Gossypium hirsutum L. JOURNAL OF EXPERIMENTAL BOTANY 2016; 67:763-74. [PMID: 26567355 PMCID: PMC4737076 DOI: 10.1093/jxb/erv494] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Diverse leaf morphology has been observed among accessions of Gossypium hirsutum, including okra leaf, which has advantages and disadvantages in cotton production. The okra leaf locus has been mapped to chromosome 15 of the Dt subgenome, but the underlying gene has yet to be identified. In this study, we used a combination of targeted association analysis, F2 population-based fine mapping, and comparative sequencing of orthologues to identify a candidate gene underlying the okra leaf trait in G. hirsutum. The okra leaf gene identified, GhOKRA, encoded a homeodomain leucine-zipper class I protein, whose closely related genes in several other plant species have been shown to be involved in regulating leaf morphology. The transcript levels of GhOKRA in shoot apices were positively correlated with the phenotypic expression of the okra leaf trait. Of the multiple sequence variations observed in the coding region among GrOKRA of Gossypium raimondii and GhOKRA-Dt of normal and okra/superokra leaf G. hirsutum accessions, a non-synonymous substitution near the N terminus and the variable protein sequences at the C terminus may be related to the leaf shape difference. Our results suggest that both transcription and protein activity of GhOKRA may be involved in regulating leaf shape. Furthermore, we found that non-reciprocal homoeologous recombination, or gene conversion, may have played a role in the origin of the okra leaf allele. Our results provided tools for further investigating and understanding the fundamental biological processes that are responsible for the cotton leaf shape variation and will help in the design of cotton plants with an ideal leaf shape for enhanced cotton production.
Collapse
|
22
|
Quantitative dual-energy computed tomography (DECT) imaging: Evaluation of system performance regarding iodine quantification accuracy. Pneumologie 2015. [DOI: 10.1055/s-0035-1556644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
23
|
Radiation Dose Reduction in Digital Plain Radiography of the Knee after Total Knee Arthroplasty. ROFO-FORTSCHR RONTG 2015; 187:685-90. [DOI: 10.1055/s-0034-1399559] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
24
|
Quantitativer Vergleich einzeitiger Dual-Energy Jodkarten als dosisreduzierte Alternative abdomineller CT-Perfusionsmessungen. ROFO-FORTSCHR RONTG 2015. [DOI: 10.1055/s-0035-1550857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion. Br J Radiol 2014; 88:20140683. [PMID: 25465353 DOI: 10.1259/bjr.20140683] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. METHODS Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R(2) and residuals of perfusion model fits were calculated. RESULTS For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p < 0.05], except when comparing NRCustom(80 kVp) with NRCustom(DE) and RRComm(80 kVp) with CG(80 kVp). NRCustom(80 kVp) and NRCustom(DE) achieved the highest reduction in metric values [NRCustom(80 kVp), 48.5%; NRCustom(DE), 45.6%; NRComm(80 kVp), 29.2%; NRCustom(VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R(2) and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. CONCLUSION Non-rigid motion correction improves spatial alignment of the target region and fit of CT perfusion models. Using DE-blended and DE-VNC images for deformable registration offers no significant improvement. ADVANCES IN KNOWLEDGE Non-rigid algorithms improve the quality of abdominal CT perfusion measurements but do not benefit from DECT post processing.
Collapse
|
26
|
Dosis-reduzierte CT-Angiografie bei Leberlebendspendern mittels 64-Zeilen CT mit Stellar-Detektoren: Vergleich der Bildqualität bei „Filtered Back Projektion“- und iterativer Rekonstruktion. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
27
|
Quantitative Dual-Energy CT Bildgebung: Systemcharakterisierung im Hinblick auf die Genauigkeit der Jodquantifizierung. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
28
|
Untersuchung der Effektivität von rigiden und deformierenden Algorithmen zur Bewegungskorrektur für die CT-Perfusionsmessung für abdominelle Organe unter Einfluss der Atembewegung. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
29
|
WE-C-103-01: Attenuation-Based Dynamic CT Bowtie Filtration: Evaluation of Signal Homogenization and Dose Reduction by Monte-Carlo Simulation. Med Phys 2013. [DOI: 10.1118/1.4815550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
30
|
Niedrigdosis-Mehrzeilendetektor-CT mit niedrigen Röhrenspannungen und iterativer Bildrekonstruktion: Wo liegt die Grenze diagnostischer Sicherheit in der Thoraxbildgebung? ROFO-FORTSCHR RONTG 2013. [DOI: 10.1055/s-0033-1346334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
31
|
Assessment of Right Ventricular Pressure-Volume Relationships Using 256-Slice CT in an Experimental Model of Acute Pulmonary Hypertension. J Heart Lung Transplant 2013. [DOI: 10.1016/j.healun.2013.01.861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
32
|
[Modern digital plain-radiography of the whole spine in scoliosis patients--dose reduction and quality criteria]. ROFO-FORTSCHR RONTG 2012; 185:48-54. [PMID: 23023231 DOI: 10.1055/s-0032-1325352] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To reduce the radiation exposure of plain radiographs of the entire spine depending on specific indications, since these are frequently performed examinations of children and young adults with scoliosis and to determine objective quality control criteria to ensure accurate assessment. MATERIALS AND METHODS In this prospective randomized study 323 patients underwent plain-radiography of the entire spine with standard and 50 % reduced dose. In an experimental pilot-study this target-dose was determined using an Alderson-Phantom. The evaluation of the experimental radiographs, as well as, the randomized plain-radiographs was conducted using the following criteria: endplates (Cobb-angle), spinal process and pedicel (rotation), lateral margin of the vertebral body (lateral alignment), identification of C7 / S1 (perpendicular). Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If one single criteria was evaluated with a score of 3 or more points or more than 2 criteria with 2 points, the radiograph was scored as "not assessable". The statistical analysis was conducted as a non-inferiority-trial. RESULTS Seven (2.4 %) of the 290 examined x-rays were scored as not assessable. There was no statistic inferiority between the examinations with standard or reduced dose, while singular assessment of the defined criteria was likewise dose-independent. CONCLUSION Plain-radiography of the total spine in patients with scoliosis can be performed with a dose reduction of 50% without a loss of validity. The obtained quality control criteria were clinically applicable.
Collapse
|
33
|
The potential of attenuation-based dynamic CT beam-shaping filter modulation as a new method for radiation dose reduction in MDCT: Evaluation by Monte-Carlo simulation of spatial dose distribution. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
34
|
Vierdimensionale Quantifizierung der Ventilation mittels dynamischer MDCT bei ARDS im Tiermodell. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
35
|
Dual-energy Computertomographie von unbehandelten, histologisch-gesicherten hepatozellulären Karzinomen: Quantitativer Vergleich der Bildqualität zwischen virtueller & konventioneller Nativbildgebung. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
36
|
Referenzwerte und Qualitätskriterien für die digitale Radiographie der Ganzwirbelsäule-Röntgenaufnahmen. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
37
|
Standardisierter Vergleich moderner MDCT-Geräte: Analyse der quantitativen Bildqualität in Abhängigkeit der Strahlenexposition für Akquisitionen bei 120 kVp und 80 kVp. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
38
|
Dual-energy CT für die Diagnose von hypervaskularisierten hepatozellulären Karzinomen (HCCs) bei Patienten mit Leberzirrhose unmittelbar vor Transplantation. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
39
|
[Phantom studies using a high-resolution CT for ex-vivo imaging of degradable magnesium implants and simulated peri-implant bone formation in rabbit tibiae]. ROFO-FORTSCHR RONTG 2012; 184:455-60. [PMID: 22434372 DOI: 10.1055/s-0031-1299293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
PURPOSE Evaluation of the suitability of the high-resolution CT XtremeCT for ex vivo imaging of degradable magnesium implants with simulated peri-implant bone formation in rabbit tibiae and development of a method for calibrating the mass concentration of a magnesium alloy in an implant volume. MATERIALS AND METHODS Using specially designed phantoms, degradable magnesium implants of the alloys LAE442, ZEK100, AX30 and MgCa 0.8 %, without coating and with peri-implant bone formation simulated by a coating, as well as rabbit tibiae were scanned. CT numbers and the contrast-to-noise-ratio (CNR) of the studied materials were determined. The visual distinction between implant and coating was evaluated. To calibrate the implant density, exemplary LAE442 pins with different mass concentrations were scanned using a specially constructed phantom. Subsequently, CT numbers corresponding to the appropriate mass concentration were determined. RESULTS The implants, coating and substantia corticalis showed a similar density. Visual distinction between coating and implant was strongly dependent on the respective magnesium alloy and chosen scan parameter. A CNR of at least 0.2 was required for a distinction between implant and coating. For the mass concentration, a high CT number linearity (R2=0.99) throughout the measuring range (1811-1273 mg/cm3 LAE442) was found. CONCLUSION As expected, the XtremeCT is primarily suitable for the imaging of bone tissue and implants. Good visual distinction of peri-implant bone formation on magnesium implants in an ex vivo phantom model ranges from possible to difficult depending on the bone density and alloy composition.
Collapse
|
40
|
|
41
|
|
42
|
Dual-energy CT-cholangiography in potential donors for living-related liver transplantation: improved biliary visualization by intravenous morphine co-medication. Eur J Radiol 2011; 81:2007-13. [PMID: 21696902 DOI: 10.1016/j.ejrad.2011.05.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2011] [Revised: 05/10/2011] [Accepted: 05/13/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.
Collapse
|
43
|
WE-C-110-09: A Theoretical Model for Calculating MDCT Beam-Shaping Filter Geometry: Comparison of Calculated Attenuation Profile and Monte-Carlo Simulated Transmission Spectra to Measurements. Med Phys 2011. [DOI: 10.1118/1.3613348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
44
|
Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure. Eur J Radiol 2011; 81:1405-12. [PMID: 21458939 DOI: 10.1016/j.ejrad.2011.03.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2010] [Revised: 02/28/2011] [Accepted: 03/03/2011] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy (DE), standard and low-kVp contrast-enhanced computed-tomography (CT) cholangiography. MATERIALS AND METHODS For each of 22 DECT-cholangiography examinations, 3 image datasets were analyzed as independent single-source CT-acquisitions at different tube potential, i.e. 80 kVp, 120 kVp-equivalent (linear blended dataset M0.3: 30% 80 kVp, 70% 140 kVp), and 140 kVp. Analysis comprised determination of IN, CNR and SNR in regions of interest (ROI) placed in liver parenchyma and contrasted bile ducts. IN was evaluated as mean standard deviation of 3 ROI placed within liver parenchyma (segments 6/7, 5/8, 2/3); CNR was assessed as bile duct-to-liver parenchyma ratio, and SNR as bile duct-to-image noise ratio. RD in terms of CT dose index (CTDI(vol)), dose-length product (DLP) and effective dose (ED) has been determined for each of the datasets, and compared to console prediction and scan summary values. Using phantom measurements of CTDI(vol), a method for separating comprehensive RD values of DE-acquisitions into the original RD contribution of each tube (80 kVp/140 kVp) has been developed, enabling comparison of all 3 datasets as if independently acquired using single-source "single-energy" technique. RESULTS Highest IN was detected for 80 kVp- (38.6 ± 5.1HU), lowest for 120 kVp-equivalent linear blended M0.3-datasets (23.1 ± 3.4HU) with significant differences between all datasets (P<0.001). Highest SNR and CNR were measured for M0.3- (SNR: 14.8 ± 4.1; CNR: 11.6 ± 3.8) and 80 kVp-datasets (SNR: 13.8 ± 4.8; CNR: 11.2 ± 4.5); lowest for 140 kVp-datasets (SNR: 9.5 ± 2.5; CNR: 7.1 ± 2.3) with significant differences between M0.3- and 140 kVp-datasets as well as between 80 kVp- and 140 kVp-datasets (both P<0.001 for both CNR, SNR). CTDI(vol), DLP and ED were reduced by 50% for low-kilovoltage acquisitions (CTDI(vol): 5.5 ± 1.4 mGy; DLP: 127.8 ± 40.1 mGy cm; ED: 1.9 ± 0.6 mSv) compared to comprehensive DE-acquisitions (CTDI(vol): 11.0 ± 2.3 mGy; DLP: 253.8 ± 67.5 mGy cm; ED: 3.8 ± 1.0 mSv, tube contribution: 80 kVp: 44.5%; 140 kVp: 55.5%), and by 20% compared to conventional acquisitions at 120 kVp (CTDI(vol): 6.71 mGy; DLP: 153.5 ± 16.9 mGy cm; ED: 2.3 ± 0.3 mSv). CONCLUSIONS Despite higher IN, low-kilovoltage CT-cholangiography reveals no significant difference with respect to CNR and SNR when compared to linear blended images yielded by DECT. Compared to DECT or conventional CT at 120 kVp, contrast-enhanced low-kVp CT cholangiography potentially allows reduction of patient dose by up to 50% or 20%, respectively. Therefore, CT-cholangiography at 80 kVp should be considered as an alternative to DECT-cholangiography whenever DECT is unavailable, or if increased image quality of DECT regarding quantitative bile duct evaluation is not needed for diagnosis.
Collapse
|
45
|
Charakterisierung des Strahlformfilters eines MDCT-Systems: Vergleich Monte-Carlo simulierter Transmissionsspektren eines Filtergeometriemodells mit gemessenen Röntgenspektren. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
46
|
Performance of static MDCT beam-shaping filtration for elliptical subject geometries in dependence of projection angle. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
47
|
Intravenous 64-multi-detector row CT-cholangiography of porcine livers: a feasibility study with definition of the temporal window for optimal bile duct delineation. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2010; 17:666-72. [PMID: 20703845 DOI: 10.1007/s00534-010-0263-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2009] [Accepted: 01/06/2010] [Indexed: 10/19/2022]
Abstract
BACKGROUND/PURPOSE To assess the feasibility of intravenous 64-multi-detector row computed tomography (CT)-cholangiography of porcine livers with definition of the temporal window for optimal bile duct delineation. METHODS Six healthy Landrace pigs, each weighing 28.97 +/- 2.99 kg, underwent 64-multi-detector row CT-cholangiography. Each pig was infused with 50 ml of meglumine iotroxate continuously over a period of 20 min and, starting with the initiation of the infusion, 18 consecutive CT scans of the abdomen at 2-min intervals were acquired. All series were evaluated for bile duct visualization scores and maximum bile duct diameters as primary study goals and bile duct attenuation and liver enhancement as secondary study goals. RESULTS Of the 16 analyzed biliary tract segments, maximum bile duct visualization scores ranged between 4.00 +/- 0.00 and 2.83 +/- 1.47. Time to maximum bile duct visualization scores ranged between 10 and 34 min. Average bile duct visualization scores for the 10- to 34-min interval ranged between 3.99 +/- 0.05 and 2.78 +/- 0.10. Maximum bile duct diameters ranged between 6.47 +/- 1.05 and 2.65 +/- 2.23 mm. Time to maximum bile duct diameters ranged between 24 and 34 min. Average bile duct diameters for the 10- to 34-min interval ranged between 6.00 +/- 0.38 and 2.40 +/- 0.13 mm. CONCLUSIONS Intravenous 64-multi-detector row CT-cholangiography of non-diseased porcine liver is feasible, with the best bile duct delineation acquired between 10 and 34 min after initiation of the contrast agent infusion.
Collapse
|
48
|
Grundlagen der Mehrzeilendetektor-CT (MDCT) – Technischer Aufbau, Prinzip der Bildrekonstruktion, Strahlenexposition. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1252244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
49
|
Dual-energy CT-Cholangiographie bei potentiellen Spendern für eine Leberlebendtransplantation. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1252890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
50
|
Effect of Intravenous Morphine Comedication on Bile Duct Visualization, Diameter and Volume Applying Intravenous CT Cholangiography in a Porcine Liver Model. Eur Surg Res 2010; 45:26-33. [DOI: 10.1159/000318163] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2009] [Accepted: 06/29/2010] [Indexed: 11/19/2022]
|