1
|
Spiral groove bearing design for improving plasma skimming in rotary blood pumps. J Artif Organs 2023:10.1007/s10047-023-01422-y. [PMID: 38153606 DOI: 10.1007/s10047-023-01422-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 10/25/2023] [Indexed: 12/29/2023]
Abstract
High-efficiency plasma skimming is hopeful to prevent hemolysis inside spiral groove bearings (SGBs) because it can exclude red blood cells from the ridge gap with a high shear force. However, no study reveals the shape design of SGBs to improve plasma skimming. Therefore, this study proposed and applied a groove design strategy to designing an optimal SGB for enhancing plasma skimming in a rotary blood pump (RBP). Initially, we proposed the design strategy that the shape of the groove for enhancing plasma skimming corresponds to the direction of blood flow in the ridge gap. Second, we visualized the cell flow in a specially designed experimental RBP to determine the direction of blood flow, which was helpful in the subsequent SGB design. Then, we created an SGB to provide superior plasma skimming and applied it to the experimental RBP. We evaluated the plasma skimming effect of SGB at rotational speeds ranging from 2400 to 3000 rpm and hematocrit conditions between 1% and 40%. At a 1% hematocrit, the plasma skimming efficiency for the entire SGB was greater than 95%. In all hematocrit conditions, the efficiency at the inner ridges of the SGB was greater than 80%. The results showed the designed SGB successfully induced excellent plasma skimming within ridge gaps. This study is the first to propose and apply a shape design strategy to generate excellent plasma skimming within an SGB. This study may contribute to the prevention of SGB hemolysis inside SGB for use in RBPs.
Collapse
|
2
|
Control method for bio-actuators based on muscle contraction model . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-6. [PMID: 38083034 DOI: 10.1109/embc40787.2023.10341011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
For the practical application of bio-actuators, it is desired to develop a precise control method for skeletal muscles. In this study, a novel model-based control method has been proposed. The control method enables skeletal muscles to exert an arbitrary magnitude of contraction force, rather than just the conventional on/off control. First, we proposed a control system to obtain the optimized electrical stimulation voltage, that can reproduce reference force. In order to actually apply the method, a bio-actuator consisting of a skeletal muscle of a frog was manufactured for a verification experiment. First, muscle contraction model parameters that could reproduce the contractile response of the gastrocnemius muscle were identified from the experimental data. Next, based on this model, the proposed control method was used to calculate the stimulation voltage to exert the reference force. The voltage was applied to the bio-actuator to control the contraction force. As a results, the output of the actuator was able to follow the stepwise reference force. Our proposed control method demonstrates the feasibility of precise control of bio-actuators.Clinical Relevance- If skeletal muscles could be used as actuators for power-assistive suits, it would be possible to develop power-assistive suits that are more compatible with people and reduce the burden on caregivers in the field of nursing care. The method proposed in this study will enable the control of skeletal muscle contraction force by electrical stimulation, bringing skeletal muscle actuators closer to practical application.
Collapse
|
3
|
Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump. Artif Organs 2023; 47:425-431. [PMID: 36305737 PMCID: PMC10098525 DOI: 10.1111/aor.14443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 09/22/2022] [Accepted: 10/15/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Mechanical circulatory support devices, such as left ventricular assist devices, have recently been used in patients with heart failure as destination therapy but the formation of thrombus in blood pumps remains a critical problem. In this study, we propose a mechanical antithrombogenic method by impeller excitation using a magnetically levitated (Maglev) centrifugal pump. Previous studies have shown that one-directional excitation prevents thrombus; however, it is effective in only one direction. In this study, we aimed to obtain a better effect by vibrating it in a circular orbit to induce uniform changes in the shear-rate field entirely around the impeller. METHODS The blood coagulation time was compared using porcine blood. (1) The flow rate was set to 1 L/min, and applied excitation was at a frequency of 280 Hz and amplitude of 3 μm. (2) Moreover, the effect was compared by varying the frequency, amplitude, and direction of the excitation. In this experiment, the flow rate was set to 0.3 L/min. RESULTS (1) The thrombus formation time was 77 min without excitation and 133 min with excitation, which was 1.7 times longer. (2) The results showed no difference between (280 Hz, 3 μm) and (50 Hz, 16 μm) circular orbital excitations, and no directional difference, with thrombus formation of 2.5 times longer under all conditions than that without excitation. CONCLUSION In the case of simple reciprocating excitation, the time was approximately 1.2 times longer. This indicated that the circular orbital excitation is more effective.
Collapse
|
4
|
Innovative experimental animal models for real-time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging. Artif Organs 2023; 47:77-87. [PMID: 35957489 DOI: 10.1111/aor.14380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/08/2022] [Accepted: 08/02/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. METHODS This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). RESULTS Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. CONCLUSIONS We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.
Collapse
|
5
|
Impact of gap size and groove design of hydrodynamic bearing on plasma skimming effect for use in rotary blood pump. J Artif Organs 2022; 25:195-203. [PMID: 35088287 DOI: 10.1007/s10047-021-01308-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 12/15/2021] [Indexed: 11/26/2022]
Abstract
Plasma skimming can exclude red blood cells from high shear regions in the gaps formed by hydrodynamic bearings in rotary blood pumps. We investigated the effect of the gap size and groove design on the plasma skimming efficiency. Spiral groove bearings (SGBs) were installed into a specially designed test rig for in vitro experiments performed using human blood. The measured gap between the ridges of the bearing and the rotor surface was 17-26 µm at a flow rate of 150 ml/min and a rotor speed of 2400 rpm. Three different patterns of SGBs were designed (SGB-0, SGB-30, and SGB-60) with various degrees of the circumferential component. The hematocrit measured by a high-speed camera was compared with the hematocrit in the circuit, and the plasma skimming efficiency for the three bearing patterns was evaluated at hematocrits of 20%, 25%, and 30%. SGB-60, which had the strongest circumferential component, provided the best plasma skimming efficiency. When the gap size was less than 20 µm, the red blood cells in the gaps between the ridges of the bearing and rotor surface reduced significantly and the efficiency became higher than 90%. The gap size had the strongest effect on producing a significant plasma skimming. The plasma skimming efficiency can be significantly improved by optimizing the bearing gap size and groove design, which facilitates the further development of SGBs for use in applications such as rotary blood pumps.
Collapse
|
6
|
Development of a resonance generator utilizing incomplete tetanus of skeletal muscle . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:7248-7251. [PMID: 34892771 DOI: 10.1109/embc46164.2021.9630681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Implantable energy harvesting system utilizing contraction of an electrically-stimulated skeletal muscle is proposed for alternative batteries of implantable medical devices. In order to realize high conversion efficiency, we propose a resonance generator utilizing vibration of the skeletal muscle, which is called as incomplete tetanus. Experimental results showed the incomplete tetanus was a suitable form for the energy harvesting and the stimulation at the frequency of 10 Hz was maximized the work of the muscle. Dimensions of the springs of the generator were designed so that its natural frequency was 10 Hz. On the simulation, the maximum generated power was achieved 122.5 μW, which is enough to power the IMDs.Clinical Relevance-The proposed system has a potential to eliminate conventional batteries in the implantable medical devices. It will be beneficial for patients since the periodical surgery for the battery replacement will be avoided.
Collapse
|
7
|
Contraction model of skeletal muscle driven by external electrical stimulation-Proposal and Identification. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4761-4764. [PMID: 34892275 DOI: 10.1109/embc46164.2021.9630281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Biohybrid actuators consisting of skeletal muscle and artificial lattice have unique characteristics such as self-growth and self-repair functions. As a first step for developing model-based design and model-based control methods for the biohybrid actuators, we have developed a muscle contraction model. When the stimulation voltage is applied to the muscle, the electrical charges are stored in the dihydropyridine receptor, and the calcium ions are released. According to the concentration of the ions, the contractile elements generate contraction force. We have modeled this phenomenon with three characteristics in the proposed model-electrical dynamic, physiological, and mechanical dynamic characteristics. Unlike the previous models, the proposed model was verified under the condition of tetanus and incomplete tetanus with the muscle length changed. The simulated contraction force showed good agreement with the experimentally measured contraction force generated by the gastrocnemius muscle of a toad.Clinical Relevance- Biohybrid actuators are expected as a new material for medical and assistive devices having a soft and flexible characteristic. This study provides a basic contraction model for such biohybrid actuators.
Collapse
|
8
|
Development of muscle connection components for implantable power generation system . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:7206-7210. [PMID: 34892762 DOI: 10.1109/embc46164.2021.9629561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We have been developing an implantable power generation system that uses muscle contraction following electrical stimulation as a permanent power source for small implantable medical devices. However, if the muscle tissue is overloaded for power generation, the tissue may rupture or blood flow may be impaired. In this study, we developed a new muscle-connecting component that solves these problems. The new connection device has three rods attached to the muscle fibers, and the force exerted on the muscle fibers is converted from horizontal to vertical when the muscle contracts. We conducted simulations with a three-dimensional (3D) model, as well as pulse wave muscle measurements and in vivo tests using the actual muscle. The pulse wave in the connecting part and its downstream were optically measured from the muscle surface, and the blood flow was not obstructed. The 3D model simulations revealed that the distribution of stress was preferable compared with the case in which a rod was stuck vertically in the muscle. In the in vivo muscle tests, the metal rod and resin parts were attached to the muscle, and a load of up to approximately 9 N was applied to the connecting part. Consequently, the connecting part was stable and integrated with the muscle, and there was no damage in the muscle. Although no long-term or histological evaluations were conducted, the device may be useful because of the intramuscular power generation owing to the minimal load applied on the part connected with the muscle.
Collapse
|
9
|
Analysis of Plasma Skimming within a Hydrodynamic Bearing Gap for Designing Spiral Groove Bearings in Rotary Blood Pumps. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:1213-1217. [PMID: 34891505 DOI: 10.1109/embc46164.2021.9629535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The blood damage problem inside the narrow hydrodynamic bearing is potentially considered to be solved by applying plasma skimming. However, the consideration of improving plasma skimming has not been included in the design of hydrodynamic bearings. The absence of experimental investigation on revealing the relationship between blood flow and plasma skimming in the bearing gap impedes the design of groove shape for plasma skimming. Thus, the present study was undertaken to evaluate how the blood flow direction and the groove shape affect plasma skimming in the bearing gap. To this end, blood tests using porcine blood were repeated three times with a hematocrit of 0.8%. The bearing gap during the tests was adjusted to 25 µm and the rotational speed was adjusted from 50 rpm to 2500 rpm. The blood flow and plasma skimming effect was evaluated based on image analysis utilizing a high-speed microscope. Results of three tests indicated that the flow direction of RBCs was dominated by the rotating surface in the bearing gap when the rotational speed increased over 1200 rpm. The best plasma skimming effect was observed when the angle between the flow direction of RBCs and the tangent line of the groove was within -10 degrees to 10 degrees. The future study will be conducted with including the consideration of plasma skimming in the bearing shape design. The findings in this study aid the future design and development of hydrodynamic bearing for use in rotary blood pumps.
Collapse
|
10
|
Quantitative investigation of platelet aggregation under high shear force for anti-platelet aggregation in vitro tests. Int J Artif Organs 2021; 44:687-693. [PMID: 34058917 DOI: 10.1177/03913988211020765] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Blood pumps are often used for hemofiltration in patients with renal failure. To design effective centrifugal blood pumps for hemofiltration, it is important to suppress clogging caused by platelet aggregation. However, the optimal conditions for conducting anti-platelet aggregation tests in vitro have not yet been established. This study aimed to quantify the effect of the shear loading value and shear loading time on platelet aggregation and determine the optimal conditions for anti-platelet aggregation testing in vitro. To quantitatively evaluate platelet aggregation in terms of the negative logarithm-platelet aggregation threshold index (NL-PATI), which reflects the propensity of residual platelets to aggregate after shear loading, the following parameters were examined: blood collection method (collected from porcine vein using a syringe or collected from a slaughterhouse), type of anticoagulant (sodium citrate or heparin), shear rate, and shear time. The results showed that platelet aggregation in porcine blood increased under a high shear load applied at shear rates of approximately 20,000 s-1 or higher for 30 s. Platelet aggregation propensity was 2-3 times higher in heparin-anticoagulated blood than in sodium citrate-anticoagulated blood. Moreover, platelet aggregation was 1.5-2 times more in blood collected from the slaughterhouse than in syringe-collected blood. Testing with an integrated shear time of 30 s or less in relation to the total blood volume may be effective for conducting in vitro circulation experiments using hemofiltration blood pumps. The conditions established in this study may be useful for hemocompatibility testing of cardiovascular devices based on NL-PATI.
Collapse
|
11
|
Novel application of indocyanine green fluorescence imaging for real-time detection of thrombus in a membrane oxygenator. Artif Organs 2021; 45:1173-1182. [PMID: 34037247 DOI: 10.1111/aor.13999] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/17/2021] [Accepted: 05/11/2021] [Indexed: 12/31/2022]
Abstract
Extracorporeal membrane oxygenation (ECMO) plays an important role in the coronavirus disease 2019 (COVID-19) pandemic. Management of thrombi in ECMO is generally an important issue; especially in ECMO for COVID-19 patients who are prone to thrombus formation, the thrombus formation in oxygenators is an unresolved issue, and it is very difficult to deal with. To prevent thromboembolic complications, it is necessary to develop a method for early thrombus detection. We developed a novel method for detailed real-time observation of thrombi formed in oxygenators using indocyanine green (ICG) fluorescence imaging. The purpose of this study was to verify the efficacy of this novel method through animal experiments. The experiments were performed three times using three pigs equipped with veno-arterial ECMO comprising a centrifugal pump (CAPIOX SL) and an oxygenator (QUADROX). To create thrombogenic conditions, the pump flow rate was set at 1 L/min without anticoagulation. The diluted ICG (0.025 mg/mL) was intravenously administered at a dose of 10 mL once an hour. A single dose of ICG was 0.25mg. The oxygenator was observed with both an optical detector (PDE-neo) and the naked eye every hour after measurement initiation for a total of 8 hours. With this dose of ICG, we could observe it by fluorescence imaging for about 15 minutes. Under ICG imaging, the inside of the oxygenator was observed as a white area. A black dot suspected to be the thrombus appeared 6-8 hours after measurement initiation. The thrombus and the black dot on ICG imaging were finely matched in terms of morphology. Thus, we succeeded in real-time thrombus detection in an oxygenator using ICG imaging. The combined use of ICG imaging and conventional routine screening tests could compensate for each other's weaknesses and significantly improve the safety of ECMO.
Collapse
|
12
|
Evaluation of real-time thrombus detection method in a magnetically levitated centrifugal blood pump using a porcine left ventricular assist circulation model. Artif Organs 2021; 45:726-735. [PMID: 33432615 DOI: 10.1111/aor.13915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/16/2020] [Accepted: 01/04/2021] [Indexed: 01/08/2023]
Abstract
Pump thrombosis induces significant complications and requires timely detection. We proposed real-time monitoring of pump thrombus in a magnetically levitated centrifugal blood pump (mag-lev pump) without using additional sensors, by focusing on the changes in the displacement of the pump impeller. The phase difference between the current and displacement of the impeller increases with pump thrombus. This thrombus detection method was previously evaluated through simulated circuit experiments using porcine blood. Evaluation of real-time thrombus detection in a mag-lev blood pump was performed using a porcine left ventricular assist circulation model in this study. Acute animal experiments were performed five times using five Japanese domestic pigs. To create thrombogenic conditions, fibrinogen coating that induces thrombus formation in a short time was applied to the inner surfaces of the pump. An inflow and an outflow cannula were inserted into the apex of the left ventricle and the carotid artery, respectively, by a minimally invasive surgical procedure that allowed minimal bleeding and hypothermia. Pump flow was maintained at 1 L/min without anticoagulation. The vibrational frequency of the impeller (70 Hz) and its vibrational amplitude (30 μm) were kept constant. The thrombus was detected based on the fact that the phase difference between the impeller displacement and input current to the magnetic bearing increases when a thrombus is formed inside a pump. The experiment was terminated when the phase difference increased by over 1° from the lowest value or when the phase difference was at the lowest value 12 hours after commencing measurements. The phase difference increased by over 1° in three cases. The pump was stopped after 12 hours in two cases. Pump thrombi were found in the pump in three cases in which the phase difference increased by over 1°. No pump thrombus was found in the other two cases in which the phase difference did not increase. We succeeded in real-time thrombus monitoring of a mag-lev pump in acute animal experiments.
Collapse
|
13
|
Verification of a thrombus induction method at the target point inside the blood pump using a fibrinogen coating for a thrombus detection study. Artif Organs 2020; 44:968-975. [DOI: 10.1111/aor.13743] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 05/19/2020] [Accepted: 05/22/2020] [Indexed: 11/26/2022]
|
14
|
Development of an Electrostatic Oral Cavity Generator Driven by Occlusal Force. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1298-1301. [PMID: 31946130 DOI: 10.1109/embc.2019.8856933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Mouthguard type sensors have been developed to monitor the healthcare-related information, which is expected to be used for pre-illness and preventive medicine. However, a method for supplying the power to these sensors is still an issue to be solved. In this paper, we propose an electrostatic oral cavity generator driven by occlusal force to supply the power for mouthguard type sensors. The proposed generator is a sheet form and consists of the lamination of the electret, dielectric elastomer and copper electrode. In this paper, we estimated the power generation with a piezoelectric generator and the proposed electrostatic generator. Then, the generators were designed and fabricated. The generated power of the prototype electrostatic generator was 18.0 μW. It was about 560 times larger than that of a piezoelectric generator with the area equivalent to four pairs of molars. Although the generated power was still smaller than the required power to drive the mouthguard sensor, we considered they can be comparable with each other by optimizing the design parameters of the generator.
Collapse
|
15
|
Detection of thrombosis in a magnetically levitated blood pump by vibrational excitation of the impeller. Artif Organs 2020; 44:594-603. [DOI: 10.1111/aor.13632] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 11/28/2019] [Accepted: 01/03/2020] [Indexed: 12/15/2022]
|
16
|
Evaluating Plasma Skimming with Whole Blood in Small Gap Region Imitating Clearance of Blood Pumps. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:5665-5669. [PMID: 31947138 DOI: 10.1109/embc.2019.8857735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Plasma skimming is the phenomenon whereby the discharge hematocrit is lower than feed hematocrit naturally occurring in the microvessels with Poiseuille flow. It has been studied in Poiseuille flow extensively. Besides, plasma skimming has also been observed and investigated in blood pumps due to its potential to prevent hemolysis by skimming blood cells out of the small gap. However, whether plasma skimming occurs in blood pumps with whole blood has not been verified. Additionally, the independent influence of rotational speed and gap size has not been clarified. Therefore, in order to lay the foundation of applying plasma skimming to the development of blood pumps and also investigate the influence of rotational speed and gap size on plasma skimming respectively, we designed a simplified geometric device which not only imitates the flow inside clearances of blood pumps, but also provides different rotational speed and gap size conditions. We first conducted the verification tests of plasma skimming using whole blood with an initial hematocrit of 44% and the gap size was varied from 10 μm to 240 μm with 10 μm interval. The plasma skimming was verified occurring when the gap was less than 70 μm at a rotational speed of 800 rpm. Since plasma skimming was confirmed, we employed 30% hematocrit blood and performed the following tests to evaluate the influence of rotational speed of 600 rpm, 700 rpm, and 800 rpm respectively. As a result, the hematocrit of sampled blood declined as the rotational speed increased from 600 rpm to 800 rpm. And there was the lowest hematocrit of 16% when the gap was adjusted to 50 μm gap size at 800 rpm. This study further promotes the possibility of applying plasma skimming to the blood pumps with higher hemocapability.
Collapse
|
17
|
Mechanical antithrombogenic properties by vibrational excitation of the impeller in a magnetically levitated centrifugal blood pump. Artif Organs 2019; 43:849-859. [DOI: 10.1111/aor.13541] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 07/11/2019] [Accepted: 07/12/2019] [Indexed: 11/27/2022]
|
18
|
Design optimization of contactless generator for implantable energy harvesting system utilizing electrically-stimulated muscle. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:358-363. [PMID: 31945915 DOI: 10.1109/embc.2019.8856414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
We propose an energy harvesting device driven by a contraction of an electrically-stimulated skeletal muscle for an alternative battery of implantable medical devices. In order to realize a durable generator, we proposed a contactless plucking mechanism utilizing parallel leaf springs and magnets, with which the generator can be driven without friction. By utilizing this mechanism, the generator can be driven not only in a contraction phase, but also a relaxant phase. We optimized the stiffness of the parallel leaf springs, air gap between the magnets, and magnetic circuit in order to maximize generated power of the generator. The generated power of the prototype in nonliving environment was evaluated. The result showed the protype could achieve 35.8 μW, the value of which is enough to drive the implantable medical devices. Finally, the generated power was evaluated in the ex-vivo experiment using a gastrocnemius muscle of a toad with a weight of 193.4 g. In this experiment, the generator achieved 18.1 μW from only 3.5 g of the skeletal muscle. Also, we confirmed that the generated power exceeded the power consumption of the electrical stimulation on the skeletal muscle. Hence, we concluded the results showed the feasibility of the energy harvesting system with proposed mechanism.
Collapse
|
19
|
Abstract
Ventricular assist devices assist in blood circulation and form a crucial component of artificial hearts. While it is important to measure parameters such as the flow rate, pressure head and viscosity of the blood, implanting additional devices to do such measurements is inadvisable. To this end, we demonstrate the adaptation of a ventricular assist device for the purpose of measuring blood viscosity. Such an approach eliminates the need for additional dedicated viscometers in artificial hearts. In the proposed method, the blood viscosity is measured by applying radial vibrational excitation to the impeller in a ventricular assist device using its magnetic levitation system. During the measurement, blood is exposed to a combination of a low shear rate (≈100/s) generated by the radial vibration of the impeller and a high shear rate (>10,000/s) generated by the impeller’s rotation. The apparent viscosity of blood depends on the shear rate, so we determined which shear rate was the dominant one in the proposed method. The measurement results showed that the viscosity measured by the proposed method was in good agreement with the reference viscosity measured with a high shear rate. The mean absolute deviation in the measurements using the proposed method and those obtained using a concentric cylindrical viscometer at a high shear rate was 0.12 mPa s for four samples of porcine blood, with viscosities ranging from 2.32 to 2.75 mPa s.
Collapse
|
20
|
Development of a contactless energy harvesting system driven by contraction of skeletal muscle for implantable medical devices. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:4648-4652. [PMID: 30441387 DOI: 10.1109/embc.2018.8513105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We propose a contactless energy harvesting system driven by the contraction of an electrically-stimulated skeletal muscle to be used to supply electrical energy to implantable medical devices. In order to realize a durable generator, the one proposed here has a contactless clutch mechanism with parallel leaf springs, with which the generator can be driven without friction. In this system, the muscle connected to the parallel leaf spring is intentionally contracted by electrical stimulation. The generator can be driven not only in the contraction phase of the muscle, but also relaxation phase. The result an evaluation showed that the prototype could generate 26.1 $\mu \mathrm{W}$ with an efficiency of 13.7%. Finally, we conducted an animal experiment using the gastrocnemius muscle of a toad with a weighing of200 g The generator was driven in the contraction phase generating 1.37 $\mu \mathrm{W}$ of power from the energy supplied by the muscle.
Collapse
|
21
|
Development of an Intelligent Ventricular Assist Device with a Function of Sensorless Thrombus Detection. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:4516-4519. [PMID: 30441355 DOI: 10.1109/embc.2018.8513137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Thrombus is one of the major problems in ventricular assist devices (VADs). However, method for detecting thrombus in early stage has not been established yet. In this study, we propose an intelligent function that the VAD itself can detect thrombus automatically and alert it to medical staffs. In the proposed method, thrombus formation inside a blood pump is detected by monitoring blood viscosity. This viscosity measurement is performed by using magnetic levitation system for the impeller. Hence, it can be implemented without any additional sensors or mechanisms in principle. For verification of the method, at first, we visualized inside of the pump during thrombus formation with measuring blood viscosity by using erythrocytes removed porcine blood. The result showed that the viscosity of the blood increased as blood coagulation progressed. Then, we conducted in vitro principle verification experiments with three different whole porcine blood. In all experiments, the measured blood viscosity increased and small thrombus was observed inside the pump. From these results, we confirmed that the proposed method has a possibility to detect and predict the thrombus in early stage.
Collapse
|
22
|
Development of a suspension type sliding planar motion table using magnetic fluid lubrication. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:065003. [PMID: 27370485 DOI: 10.1063/1.4953653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A sliding planar motion table system that can be used for the lens driving actuator of a laser cutting machine was developed. The system uses magnetic fluid as the lubricant to avoid the leakage of lubricating oil under the table and reduce environmental pollution. The motion table is suspended from the guide surface by an attractive force generated by electromagnets to reduce the contact and frictional forces between the table and the guide surface. The table is capable of movement in one rotational and two translational directions over the guide surface using six electromagnets and three non-contact displacement sensors. Experimental results showed that the magnetic suspension of the table reduced the friction by 82.1% compared to the friction that would otherwise be generated by the dead weight of the table. Circular motion within a diameter of 2 mm was achieved with resolutions of 5 μm and 20 μrad in the translational and rotational directions, respectively. A bandwidth of higher than 100 Hz was also achieved in the three movement directions.
Collapse
|
23
|
Implantable power generation system utilizing muscle contractions excited by electrical stimulation. Proc Inst Mech Eng H 2016; 230:569-78. [PMID: 27006422 DOI: 10.1177/0954411916638889] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2015] [Accepted: 02/22/2016] [Indexed: 11/16/2022]
Abstract
An implantable power generation system driven by muscle contractions for supplying power to active implantable medical devices, such as pacemakers and neurostimulators, is proposed. In this system, a muscle is intentionally contracted by an electrical stimulation in accordance with the demands of the active implantable medical device for electrical power. The proposed system, which comprises a small electromagnetic induction generator, electrodes with an electrical circuit for stimulation and a transmission device to convert the linear motion of the muscle contractions into rotational motion for the magneto rotor, generates electrical energy. In an ex vivo demonstration using the gastrocnemius muscle of a toad, which was 28 mm in length and weighed 1.3 g, the electrical energy generated by the prototype exceeded the energy consumed for electrical stimulation, with the net power being 111 µW. It was demonstrated that the proposed implantable power generation system has the potential to replace implantable batteries for active implantable medical devices.
Collapse
|
24
|
Sensorless Viscosity Measurement in a Magnetically-Levitated Rotary Blood Pump. Artif Organs 2015; 39:559-68. [DOI: 10.1111/aor.12440] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
25
|
A cost-effective extracorporeal magnetically-levitated centrifugal blood pump employing a disposable magnet-free impeller. Proc Inst Mech Eng H 2011; 225:1149-57. [DOI: 10.1177/0954411911422842] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In the field of rotary blood pumps, contactless support of the impeller by a magnetic bearing has been identified as a promising method to reduce blood damage and enhance durability. The authors developed a two-degrees-of-freedom radial controlled magnetic bearing system without a permanent magnet in the impeller in order that a low-cost disposable pump-head for an extracorporeal centrifugal blood pump could be manufactured more easily. Stable levitation and contactless rotation of the ‘magnet-free’ impeller were realized for a prototype blood-pump that made use of this magnetic bearing. The run-out of the impeller position at between 1000 r/min and 3000 r/min was less than 40 µm in the radial-controlled directions. The total power consumption of the magnetic bearing was less than 1 W at the same rotational speeds. When the pump was operated, a flow rate of 5 l/min against a head pressure of 78.66 kPa was achieved at a rotational speed of 4000 r/min, which is sufficient for extracorporeal circulation support. The proposed technology offers the advantage of low-cost mass production of disposable pump heads.
Collapse
|
26
|
Development of a Disposable Magnetically Levitated Centrifugal Blood Pump (MedTech Dispo) Intended for Bridge-to-Bridge Applications-Two-Week In Vivo Evaluation. Artif Organs 2010; 34:778-83. [DOI: 10.1111/j.1525-1594.2010.01107.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
27
|
Development of a Disposable Maglev Centrifugal Blood Pump Intended for One-Month Support in Bridge-to-Bridge Applications: In Vitro and Initial In Vivo Evaluation. Artif Organs 2009; 33:704-13. [DOI: 10.1111/j.1525-1594.2009.00900.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
28
|
Abstract
A magnetically levitated centrifugal blood pump (MedTech Dispo) has been developed for use in a disposable extracorporeal system. The design of the pump is intended to eliminate mechanical contact with the impeller, to facilitate a simple disposable mechanism, and to reduce the blood-heating effects that are caused by motors and magnetic bearings. The bearing rotor attached to the impeller is suspended by a two degrees-of-freedom controlled radial magnetic bearing stator, which is situated outside the rotor. In the space inside the ringlike rotor, a magnetic coupling disk is placed to rotate the rotor and to ensure that the pump head is thermally isolated from the motor. In this system, the rotor can exhibit high passive stiffness due to the novel design of the closed magnetic circuits. The disposable pump head, which has a priming volume of 23 mL, consists of top and bottom housings, an impeller, and a rotor with a diameter of 50 mm. The pump can provide a head pressure of more than 300 mm Hg against a flow of 5 L/min. The normalized index of hemolysis of the MedTech Dispo is 0.0025 +/- 0.0005 g/100 L at 5 L/min against 250 mm Hg. This is one-seventh of the equivalent figure for a Bio Pump BPX-80 (Medtronic, Inc., Minneapolis, MN, USA), which has a value of 0.0170 +/- 0.0096 g/100 L. These results show that the MedTech Dispo offers high pumping performance and low blood trauma.
Collapse
|
29
|
Hemolytic Performance of a MagLev Disposable Rotary Blood Pump (MedTech Dispo): Effects of MagLev Gap Clearance and Surface Roughness. Artif Organs 2006; 30:949-54. [PMID: 17181835 DOI: 10.1111/j.1525-1594.2006.00332.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Mechanical shaft seal bearing incorporated in the centrifugal blood pumps contributes to hemolysis and thrombus formation. In addition, the problem of durability and corrosion of mechanical shaft seal bearing has been recently reported from the safety point of view. To amend the shortcomings of the blood-immersed mechanical bearings, a magnetic levitated centrifugal rotary blood pump (MedTech Dispo Model 1; Tokyo Medical and Dental University, Tokyo, Japan) has been developed for extracorporeal disposable application. In this study, the hemolytic performance of the MedTech Dispo Model 1 centrifugal blood pump system was evaluated, with special focus on the narrow blood path clearance at the magnetic bearing between rotor and stator, and on the pump housing surface roughness. A pump flow of 5 L/min against the head pressure of 100 mm Hg for 4 h was included in the hemolytic test conditions. Anticoagulated fresh porcine blood was used as a working fluid. The clearance of blood path at the magnetic bearing was in the range of 100-250 micro m. Pump housing surface roughness was controlled to be around Ra = 0.1-1.5 micro m. The lowest hemolytic results were obtained at the clearance of 250 micro m and with the polished surface (Ra = 0.1 micro m) yielding the normalized index of hemolysis (NIH) of less than 0.001 g/100 L, which was 1/5 of the Biopump BP-80 (Medtronic Inc., Minneapolis, MN, USA, and 1/4 of the BPX-80. In spite of rough surface and narrow blood path, NIH levels were less than clinically acceptable level of 0.005 g/100 L. The noncontact, levitated impeller system is useful to improve pump performance in blood environment.
Collapse
|
30
|
Abstract
The magnetically levitated (Mag-Lev) centrifugal rotary blood pump (CRBP) with two-degrees-of-freedom active control is promising for safe and long-term support of circulation. In this study, Mag-Lev CRBP controllability and impeller behavior were studied in the simulated heart failure circulatory model. A pneumatically driven pulsatile blood pump (Medos VAD [ventricular assist device]-54 mL) was used to simulate the left ventricle (LV). The Mag-Lev CRBP was placed between the LV apex and aortic compliance tank simulating LV assistance. The impeller behavior in five axes (x, y, z, theta, and phi) was continuously monitored using five eddy current sensors. The signals of the x- and y-axes were used for feedback active control, while the behaviors of the other three axes were passively controlled by the permanent magnets. In the static mock circuit, the impeller movement was controlled to within +/-10-+/-20 microm in the x- and y-axes, while in the pulsatile circuit, LV pulsation was modulated in the impeller movement with the amplitude being 2-22 microm. The amplitude of impeller movement measured at 1800 rpm with the simulated failing heart (peak LV pressure [LVP] = 70 mm Hg, mean aortic pressure [AoP(mean)] = 55 +/- 20 mm Hg, aortic flow = 2.7 L/min) was 12.6 microm, while it increased to 19.2 microm with the recovered heart (peak LVP = 122 mm Hg, AoP(mean) = 100 +/- 20 mm Hg, aortic flow = 3.9 L/min). The impeller repeated the reciprocating movement from the center of the pump toward the outlet port with LV pulsation. Angular rotation (theta, phi) was around +/-0.002 rad without z-axis displacement. Power requirements ranged from 0.6 to 0.9 W. Five-axis impeller behavior and Mag-Lev controller stability were demonstrated in the pulsatile mock circuit. Noncontact drive and low power requirements were shown despite the effects of LV pulsation. The impeller position signals in the x- and y-axes reflected LV function. The Mag-Lev CRBP is effective not only for noncontact low power control of the impeller, but also for diagnosis of cardiac function noninvasively.
Collapse
|