1
|
Influence of screw channel angulation on reverse torque value and fracture resistance in monolithic zirconia restorations after thermomechanical cycling: an in-vitro study. BMC Oral Health 2024; 24:389. [PMID: 38532413 DOI: 10.1186/s12903-024-04171-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 03/20/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.
Collapse
|
2
|
The effect of repair protocols and chewing simulation on the microtensile bond strength of two resin matrix ceramics to composite resin. BMC Oral Health 2024; 24:171. [PMID: 38308281 PMCID: PMC10837933 DOI: 10.1186/s12903-024-03932-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 01/24/2024] [Indexed: 02/04/2024] Open
Abstract
BACKGROUND To assess the micro tensile bond strength (µTBS) of two resin matrix ceramic (RMC) blocks bonded to composite resin by using different repair protocols with and without chewing simulation (CS). MATERIALS AND METHODS Two resin matrix ceramic blocks (Vita Enamic and Lava Ultimate) were divided into 4 groups according to the surface treatments: Bur grinding (control), Bur grinding + silane, 9.5% HF acid etching, and 9.5% HF acid etching + silane. The single bond universal adhesive was applied on all specimens after the surface treatments according to the manufacturer's instructions, it was administered actively on the treated surface for 20 s and then light cured for 10 s, followed by incremental packing of composite resin to the treated surface. Each group was further divided into 2 subgroups (with/without chewing simulation for 500,000 cycles). A micro tensile bond strength test was performed for each group (n = 15). The effect of surface treatments on the materials was examined by using a scanning electron microscope (SEM). The micro tensile bond strength (MPa) data were analyzed with a three-way ANOVA, the independent t-test, and one-way ANOVA followed by the Tukey post-hoc test. RESULTS µTBS results were significantly higher for Lava Ultimate than Vita Enamic for all the surface treatment protocols with (p < 0.01). The chewing simulation significantly negatively affected the micro-tensile bond strength (p < 0.001). Bur grinding + saline exhibited the highest bond strength values for Lava Ultimate, both with and without chewing simulation. For Vita Enamic, bur grinding + saline and HF acid + saline showed significantly higher bond strength values compared to other surface treatments, both with and without chewing simulation (p ≤ 0.05). CONCLUSION Bur grinding + silane could be recommended as a durable repair protocol for indirect resin matrix ceramics blocks with composite resin material.
Collapse
|
3
|
Atomic Force Microscopy of Viruses: Stability, Disassembly, and Genome Release. Methods Mol Biol 2024; 2694:317-338. [PMID: 37824011 DOI: 10.1007/978-1-0716-3377-9_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
In atomic force microscopy (AFM), the probe is a nanometric tip located at the end of a microcantilever which palpates the specimen under study as a blind person manages a walking stick. In this way, AFM allows obtaining nanometric resolution images of individual protein shells, such as viruses, in liquid milieu. Beyond imaging, AFM also enables not only the manipulation of single protein cages but also the evaluation of each physicochemical property which is able of inducing any measurable mechanical perturbation to the microcantilever that holds the tip. In this chapter, we start revising some recipes for adsorbing protein shells on surfaces and how the geometrical dilation of tips can affect to the AFM topographies. This work also deals with the abilities of AFM to monitor TGEV coronavirus under changing conditions of the liquid environment. Subsequently, we describe several AFM approaches to study cargo release, aging, and multilayered viruses with single indentation and fatigue assays. Finally, we comment on a combined AFM/fluorescence application to study the influence of crowding on GFP packed within individual P22 bacteriophage capsids.
Collapse
|
4
|
Mechanical fatigue testing in silico: Dynamic evolution of material properties of nanoscale biological particles. Acta Biomater 2023; 166:326-345. [PMID: 37142109 DOI: 10.1016/j.actbio.2023.04.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 04/01/2023] [Accepted: 04/26/2023] [Indexed: 05/06/2023]
Abstract
Biological particles have evolved to possess mechanical characteristics necessary to carry out their functions. We developed a computational approach to "fatigue testing in silico", in which constant-amplitude cyclic loading is applied to a particle to explore its mechanobiology. We used this approach to describe dynamic evolution of nanomaterial properties and low-cycle fatigue in the thin spherical encapsulin shell, thick spherical Cowpea Chlorotic Mottle Virus (CCMV) capsid, and thick cylindrical microtubule (MT) fragment over 20 cycles of deformation. Changing structures and force-deformation curves enabled us to describe their damage-dependent biomechanics (strength, deformability, stiffness), thermodynamics (released and dissipated energies, enthalpy, and entropy) and material properties (toughness). Thick CCMV and MT particles experience material fatigue due to slow recovery and damage accumulation over 3-5 loading cycles; thin encapsulin shells show little fatigue due to rapid remodeling and limited damage. The results obtained challenge the existing paradigm: damage in biological particles is partially reversible owing to particle's partial recovery; fatigue crack may or may not grow with each loading cycle and may heal; and particles adapt to deformation amplitude and frequency to minimize the energy dissipated. Using crack size to quantitate damage is problematic as several cracks might form simultaneously in a particle. Dynamic evolution of strength, deformability, and stiffness, can be predicted by analyzing the cycle number (N) dependent damage, [Formula: see text] , where α is a power law and Nf is fatigue life. Fatigue testing in silico can now be used to explore damage-induced changes in the material properties of other biological particles. STATEMENT OF SIGNIFICANCE: Biological particles possess mechanical characteristics necessary to perform their functions. We developed "fatigue testing in silico" approach, which employes Langevin Dynamics simulations of constant-amplitude cyclic loading of nanoscale biological particles, to explore dynamic evolution of the mechanical, energetic, and material properties of the thin and thick spherical particles of encapsulin and Cowpea Chlorotic Mottle Virus, and the microtubule filament fragment. Our study of damage growth and fatigue development challenge the existing paradigm. Damage in biological particles is partially reversible as fatigue crack might heal with each loading cycle. Particles adapt to deformation amplitude and frequency to minimize energy dissipation. The evolution of strength, deformability, and stiffness, can be accurately predicted by analyzing the damage growth in particle structure.
Collapse
|
5
|
A continuum damage model of fatigue and failure in whole bone. J Mech Behav Biomed Mater 2023; 143:105907. [PMID: 37216754 DOI: 10.1016/j.jmbbm.2023.105907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/08/2023] [Accepted: 05/12/2023] [Indexed: 05/24/2023]
Abstract
Predicting the fatigue failure of whole bone may provide insight into the etiology of stress fractures and lead to new methods for preventing and rehabilitating these injuries. Although finite element (FE) models of whole bone have been used to predict fatigue failure, they often do not consider the cumulative and nonlinear effect of fatigue damage, which causes stress redistribution over many loading cycles. The purpose of this study was to develop and validate a continuum damage mechanics FE model for the prediction of fatigue damage and failure. Sixteen whole rabbit-tibiae were imaged using computed tomography (CT) and then cyclically loaded in uniaxial compression until failure. CT images were used to generate specimen-specific FE models and a custom program was developed to iteratively simulate cyclic loading and progressive modulus degradation associated with mechanical fatigue. Four tibiae from the experimental tests were used to develop a suitable damage model and define a failure criterion; the remaining twelve tibiae were used to test the validity of the continuum damage mechanics model. Fatigue-life predictions explained 71% of the variation in experimental fatigue-life measurements with a directional bias towards over-predicting fatigue-life in the low-cycle regime. These findings demonstrate the efficacy of using FE modeling with continuum damage mechanics to predict damage evolution and fatigue failure of whole bone. Through further refinement and validation, this model may be used to investigate different mechanical factors that influence the risk of stress fractures in humans.
Collapse
|
6
|
Biomechanical evaluation of abutment stability in morse taper implant connections in different times: A retrospective clinical study compared with an in vitro analysis. Heliyon 2023; 9:e15312. [PMID: 37151670 PMCID: PMC10161598 DOI: 10.1016/j.heliyon.2023.e15312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/08/2023] [Accepted: 04/03/2023] [Indexed: 05/09/2023] Open
Abstract
Objectives Micromotion between a dental implant and abutment can adversely affect clinical performance and compromise successful osseointegration by creating a bacterial harbor, enabling screw loosening, and imparting disruptive lateral forces on the cortical bone. Thus, the aim of the present study was to measure the abutment stability evolution using resonance frequency analysis (RFA) in vivo at four different times (baseline, 3, 4, and 12 months), and compare these data obtained with the RFA measured after mechanical cycling (in vitro) corresponding to the proposed times in numbers of cycles. Methods To evaluate the abutment stability, RFA was performed in 70 sets of implant/abutment (IA) with a total of 54 patients (31 women, 23 men). These IA sets were divided into three groups, according to the abutment angulation: straight abutment (Abt1 group), 17-degree angled abutment (Abt2 group), and 30-degree angled abutment (Abt3 group). Abutment stability was measured immediately at implant placement and the abutment installation (T1), 3 (T2), 4 (T3), and 12 months (T4) later. For the in vitro analysis, ten sets of each group were submitted to mechanical cycling: T1 = 0 cycles, T2 = 90,000 cycles, T3 = 120,000 cycles, and T4 = 360,000 cycles. All data collected were statistically evaluated using the GraphPad Prism 5.01 software, with the level of significance was α = 0.05. Results In vivo, the overall data of implant stability quotient (ISQ) values obtained for all groups in each evaluation time were 61.5 ± 3.94 (95% CI: [60-63]) at T1, 62.8 ± 3.73 (95% CI, [61-64]) at T2, 63.4 ± 3.08 (95% CI: [61-64]) at T3, and 65.5 ± 4.33 (95% CI: [63-68]) at T4. Whereas in vitro, the ISQ were 61.5 ± 2.66 (95% CI: [59-63]) at T1, 63.2 ± 3.02 (95% CI, [61-65]) at T2, 63.9 ± 2.55 (95% CI: [62-66]) at T3, and 66.5 ± 2.97 (95% CI: [64-68]) at T4. In both evaluations (in vivo and in vitro), the data showed a significant difference (ANOVA test with p < 0.0001). Conclusions The RFA to measure the abutment stability used in this study showed that there was a progressive increase in stability among the predetermined times for the measurements, in both analysis (in vivo and in vitro). Furthermore, the values at each time point were similar, with no statistical difference between them.
Collapse
|
7
|
The probability of whole-bone fatigue fracture can be accurately predicted using specimen-specific finite element analysis incorporating a stochastic failure model. J Biomech 2022; 143:111273. [PMID: 36049387 DOI: 10.1016/j.jbiomech.2022.111273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 08/09/2022] [Accepted: 08/22/2022] [Indexed: 11/21/2022]
Abstract
A better understanding of the mechanisms of mechanical fatigue in bone could help improve understanding of the etiology of stress fractures. Investigations of small material samples of bone have identified a nonlinear relationship between strain magnitude, strained volume, and fatigue life, but it is non-trivial to extend these principles to predict the fatigue-life of whole bones which experience complex loading and non-uniform strain distribution. The purpose of this investigation was to experimentally validate a specimen-specific finite element (FE) model that predicts whole-bone fatigue failure using a stochastic model based on strain magnitude and volume. Thirty-four rabbit tibiae were previously tested to failure under cyclic compression, torsion, or both. Strain distribution during the test was estimated from computed-tomography based specimen-specific FE models, and a stochastic failure model based on strain magnitude and volume was used to predict the probability of failure as a function of loading cycles. Model predicted fracture risk matched experimental observations. Respectively, for the 25%, 50%, 75%, and 95% probabilistic predictions, we observed experimental failure ≤ model predicted values in 41%, 53%, 76%, and 80% of the tested specimens. A Brier scoring rule further demonstrated that this model, using strain magnitude and volume, more accurately predicted failure probability compared to two reference models that considered strain magnitude only. In conclusion, the stochastic model may be a powerful tool in future studies to assess mechanical factors that influence stress fracture risk.
Collapse
|
8
|
Harbor and coastal structures: A review of mechanical fatigue under random wave loading. Heliyon 2021; 7:e08241. [PMID: 34761133 PMCID: PMC8566781 DOI: 10.1016/j.heliyon.2021.e08241] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 10/04/2021] [Accepted: 10/20/2021] [Indexed: 11/16/2022] Open
Abstract
Harbor and coastal structures are essential in maritime connections. Additionally, some offshore structures near the coast are important for supplying energy as a material or transforming the natural resources into energy, as in wind turbines. One of the main issues that needs to be overcome in terms of these structures is mechanical fatigue due to the loads of the structure by its function and waves, wind, the current seawater level, and ice. Structural design has to meet high target loads to ensure that structures can endure extreme marine conditions under the assumption of the probability of loads and based on marine conditions, can mask damage where component immersions are not available for inspection. In this work, the wave loads and fatigue damage under random processes are reviewed.
Collapse
|
9
|
Stressed volume estimated by finite element analysis predicts the fatigue life of human cortical bone: The role of vascular canals as stress concentrators. Bone 2021; 143:115647. [PMID: 32956853 DOI: 10.1016/j.bone.2020.115647] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 09/09/2020] [Accepted: 09/11/2020] [Indexed: 10/23/2022]
Abstract
The fatigue life of cortical bone can vary several orders of magnitude, even in identical loading conditions. A portion of this variability is likely related to intracortical microarchitecture and the role of vascular canals as stress concentrators. The size, spatial distribution, and density of canals determine the peak magnitude and volume of stress concentrations. This study utilized a combination of experimental fatigue testing and image-based finite element (FE) analysis to establish the relationship between the stressed volume (i.e., volume of bone above yield stress) associated with vascular canals and the fatigue life of cortical bone. Thirty-six cortical bone samples were prepared from human femora and tibiae from five donors. Samples were allocated to four loading groups, corresponding to stress ranges of 60, 70, 80, and 90 MPa, then cyclically loaded in zero-compression until fracture. Porosity, canal diameter, canal separation, and canal number for each sample was quantified using X-ray microscopy (XRM) after testing. FE models were created from XRM images and used to calculate the stressed volume. Stressed volume was a good predictor of fatigue life, accounting for 67% of the scatter in fatigue-life measurements. An increase in stressed volume was most strongly associated with higher levels of intracortical porosity and larger canal diameters. The findings from this study suggest that a large portion of the fatigue-life variance of cortical bone in zero-compression is driven by intracortical microarchitecture, and that fatigue failure may be predicted by quantifying the stress concentrations associated with vascular canals.
Collapse
|
10
|
Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study. Bone Rep 2020; 12:100254. [PMID: 32258250 PMCID: PMC7110329 DOI: 10.1016/j.bonr.2020.100254] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 02/26/2020] [Accepted: 03/02/2020] [Indexed: 11/18/2022] Open
Abstract
Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples to large doses of radiation that may compromise fatigue resistance. The purpose of this pilot study was to 1) investigate the relationship between intracortical microarchitecture and the fatigue life of human bone in compression and 2) examine the effects of synchrotron irradiation on fatigue life measurements. Cortical samples were prepared from the femoral and tibial shafts of three cadaveric donors. A subset of samples was imaged using synchrotron X-ray microCT to quantify microarchitecture, including porosity, canal diameter, lacunar density, lacunar volume, and lacunar orientation. A second group of control samples was not imaged and used only for mechanical testing. Fatigue life was quantified by cyclically loading both groups in zero-compression until failure. Increased porosity and larger canal diameter were both logarithmically related to a shorter fatigue life, whereas lacunar density demonstrated a positive linear relationship with fatigue life (r2 = 45–73%, depending on measure). Irradiation from microCT scanning reduced fatigue life measurements by 91%, but relationships with microarchitecture measurements remained. Additional research is needed to support the findings of this pilot study and fully establish the relationship between intracortical microarchitecture and the compressive fatigue life of bone. Increased porosity and larger canal diameters were associated with a shorter compressive fatigue life. A higher lacunar density was related to a longer compressive fatigue life. Irradiation from synchrotron X-ray microCT scanning reduced fatigue life by 91%. The influence of microarchitecture on fatigue life exhibited similar trends for both irradiated and non-irradiated bone.
Collapse
|
11
|
Critical considerations on load-to-failure test for monolithic zirconia molar crowns. J Mech Behav Biomed Mater 2018; 87:180-189. [PMID: 30077077 DOI: 10.1016/j.jmbbm.2018.07.034] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 07/19/2018] [Accepted: 07/24/2018] [Indexed: 11/30/2022]
Abstract
Application of monolithic zirconia crowns (MZCs) with reduced thickness to the molar region has been proposed, but potential complications have yet to be fully evaluated in laboratory tests. The present study aimed to develop a clinically relevant load-to-failure test in combination with fatigue treatments involving thermal and mechanical cycling (TC and MC) to evaluate the fracture resistance of molar MZCs. MZCs with a minimal thickness of 0.5 mm were bonded to dies made of resin-based composite (RBC), epoxy resin (EP), or polyoxymethylene-copolymer (POM-C). The samples were either untreated (UT) or subjected to TC (5-55 °C for 1 × 105 cycles) and MC (300 N for 2.4 × 106 cycles). The stress generated by TC and MC was simulated by finite element modeling. The load-to-failure test was performed using an inverse V-shaped two-plane indenter and was followed by fractographic analysis. The median values of fracture load for MZC/RBC and MZC/EP in the TC group were significantly lower than those in the UT group. MC also decreased the median value of fracture load for MZC/RBC significantly, but not that for MZC/EP and MZC/POM-C. Fractography revealed that the fracture started in the cervical area in all groups, which is similar to clinically failed crowns. The simulation confirmed stress concentration at the cervical area in both TC and MC groups. The present study suggests that the load-to-failure test using a two-plane indenter could induce clinically relevant fracture of MZCs, the vulnerability of the MZCs depends largely on the die material employed, and MZCs are more likely to be damaged by thermal fatigue than mechanical fatigue.
Collapse
|
12
|
Interfacial degradation of adhesive composite restorations mediated by oral biofilms and mechanical challenge in an extracted tooth model of secondary caries. J Dent 2017; 66:62-70. [PMID: 28843960 DOI: 10.1016/j.jdent.2017.08.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 08/13/2017] [Accepted: 08/16/2017] [Indexed: 01/05/2023] Open
Abstract
OBJECTIVE To study the combined effect of simulated occlusal loading and plaque-derived biofilm on the interfacial integrity of dental composite restorations, and to explore whether the effects are modulated by the incorporation of sucrose. METHODS MOD-class-II restorations were prepared in third molars. Half of the specimens (n=27) were subjected to 200,000 cycles of mechanical loading using an artificial oral environment (ART). Then, both groups of specimens (fatigued and non-fatigued) were divided into three subgroups for testing in CDC-reactors under the following conditions: no biofilm (Control), biofilm with no sucrose (BNS) and biofilm pulsed with sucrose (BWS). BNS and BWS reactors were incubated with a multispecies inoculum from a single plaque donor whereas the control reactor was not. The BWS reactor was pulsed with sucrose five times a day. The biofilm challenges were repeated sequentially for 12 weeks. pH was recorded for each run. Specimens were examined for demineralization with micro-CT and load capacity by fast fracture test. RESULTS Demineralization next to the restorations was only detectable in BWS teeth. Fracture loads were significantly reduced by the concomitant presence of biofilm and sucrose, regardless of whether cyclic mechanical loading was applied. Cyclic loading reduced fracture loads under all reactor conditions, but the reduction was not statistically significant. CONCLUSIONS Sucrose pulsing was required to induce biofilm-mediated degradation of the adhesive interface. We have presented a comprehensive and clinically relevant model to study the effects of mechanical loading and microbial challenge on the interfacial integrity of dental restorations.
Collapse
|
13
|
TMJ energy densities in healthy men and women. Osteoarthritis Cartilage 2017; 25:846-849. [PMID: 28064032 PMCID: PMC5438898 DOI: 10.1016/j.joca.2016.12.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Revised: 12/24/2016] [Accepted: 12/29/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Cartilage fatigue, due to mechanical work, may account for the early development of degenerative joint disease (DJD) in the temporomandibular joint (TMJ), and why women are three times more likely to be afflicted. This study tested for gender differences in mechanical energy densities in women and men with healthy TMJs. DESIGN Eighteen women and eighteen men gave informed consent. Research diagnostic criteria including imaging were used to ensure that subjects' TMJs were normal, without disc displacement or signs of DJD. Numerical modeling determined TMJ loads (Fnormal). Jaw tracking and three-dimensional dynamic stereometry characterized individual-specific data of stress-field dynamic mechanics during 10 symmetrical jaw closing cycles. These data were used to estimate tractional forces (Ftraction). Energy densities were then calculated, where: Energy Density = W/Q (W = work done or mechanical energy input = Ftraction*distance of stress-field translation, Q = volume of cartilage). Two-way analysis of variance (ANOVA) and follow-up two-group comparisons tested mean energy densities for ipsilateral and contralateral TMJs in women vs men. RESULTS Mean energy densities ± standard deviations in ipsilateral and contralateral TMJs in women were 9.0 ± 9.7 and 8.4 ± 5.5 mJ/mm3, respectively, and were significantly larger (P = 0.004 and 0.001, respectively) compared to ipsilateral and contralateral TMJs in men, which were 5.6 ± 4.2 and 6.3 ± 4.2 mJ/mm3, respectively. CONCLUSIONS Energy densities were significantly larger in healthy TMJs of women than men. Larger TMJ energy densities during normal jaw functions could predispose earlier mechanical fatigue of the TMJ disc.
Collapse
|
14
|
An experimental analysis of shell failure in breast implants. J Mech Behav Biomed Mater 2017; 72:22-28. [PMID: 28437660 DOI: 10.1016/j.jmbbm.2017.04.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 04/05/2017] [Indexed: 11/18/2022]
Abstract
Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast implants increased. The objective of this research is to analyze and describe the rupture characteristics of failed explanted PIP implants to study the modes and causes of rupture. Eleven explanted PIP implants were analyzed by visual inspection and scanning electron microscopy (SEM). To simulate hypothetical ruptures caused by cyclic mechanical stress (fatigue) in the implant shell, two control implants were submitted to fatigue tests, and analyzed with SEM. Small ruptures (either Hole or split) striations were found, which normally appear due to fatigue phenomena. Similar striations were also found in specimens (control) tested under laboratory controlled conditions. In the context of this work, the striations found in explants constitute a significant finding as they point to the occurrence of fatigue phenomena associated with mammary implants rupture. This research, also demonstrates that rupture surface analysis of explanted breast implants has the potential to become a useful indicator for assessing implant rupture mechanisms.
Collapse
|
15
|
A novel insight into keratoconus: mechanical fatigue of the cornea. MEDICAL HYPOTHESIS, DISCOVERY & INNOVATION OPHTHALMOLOGY JOURNAL 2012; 1:14-7. [PMID: 24600612 PMCID: PMC3939737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
An integrated model for keratectasia risk assessment has received much attention over many years. The objective of this article is to propose a more complete, conceptual model by which high risk individuals can be screened, even with no topographic irregularity or corneal thinning. In this model, corneal ectasia results from the fatigue effect of cyclic shear stress and tensile stress, caused by eye rubbing and fluctuating intraocular pressure (IOP), respectively, on corneal microstructures. The model clarifies the importance of the magnitude of shearing force applied by eye rubbing, the amplitude of IOP fluctuations, the frequency of eye rubbing and IOP fluctuations, the geometry of the cornea, the temperature of the cornea, and the effects of oxidative stress on the cornea in keratectasia development. Therefore, preoperative screening strategies based on these concepts can be designed to assess the risk of keratectasia at an early stage, and select the best candidates who can benefit from keratorefractive surgeries.
Collapse
|