1
|
Yao PC, Fei ZT, Chen M, Mo BF, Zhang R, Yang YL, Sun J, Wang QS, Li YG. Incidence, impact and predictors of residual device patency after left atrial appendage closure with the LACbes device. Int J Cardiol 2024; 397:131640. [PMID: 38065326 DOI: 10.1016/j.ijcard.2023.131640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/09/2023] [Accepted: 12/03/2023] [Indexed: 12/22/2023]
Abstract
BACKGROUND The residual device patency (RDP) after left atrial appendage closure (LAAC) with the LACbes device has not been specifically explored in atrial fibrillation (AF) patients. This study aims to explore the incidence, impact and predictors of RDP detected by cardiac computed tomography angiography (CCTA) post LAAC. METHODS AF patients implanted with the LACbes device were prospectively enrolled. CCTA device surveillance was performed at 3 months post-procedure. Major adverse events (MAEs), including stroke/transient ischemic attack, major bleeding and all-cause death, were evaluated. RESULTS Among 141 patients with CCTA surveillance, 56 (39.7%) showed no visible leak and 85 (60.3%) showed RDP. During the median follow-up of 443 [232, 706] days, the presence of RDP was not associated with an increased risk of MAEs (adjusted hazard ratio [HR]: 4.07, 95% confidence interval [CI]: 0.49-34.24, p = 0.196), while peri-device leak (PDL) at the lobe was associated with heightened risks of MAEs (adjusted HR: 6.85, 95% CI: 1.62-28.89, p = 0.009). In patients with PDL at the lobe, antiplatelet after 6 months (HR: 0.20, 95% CI: 0.05-0.91, p = 0.038) was independent protective predictor of MAEs. Besides, current smoking (odds ratio [OR]: 7.52, 95% CI: 2.68-21.08, p < 0.001) and maximum diameter of LAA orifice (OR: 1.16, 95% CI: 1.00-1.34, p = 0.048) were independent predictors of PDL at the lobe. CONCLUSIONS Presence of PDL at the device lobe detected by CCTA at 3-month post LAAC with LACbes is associated with unfavorable prognosis in AF patients. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT03788941.
Collapse
Affiliation(s)
- Peng-Cheng Yao
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Zhen-Tao Fei
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Mu Chen
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Bin-Feng Mo
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Rui Zhang
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yu-Li Yang
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jian Sun
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qun-Shan Wang
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yi-Gang Li
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
2
|
Samaras A, Papazoglou AS, Balomenakis C, Bekiaridou A, Moysidis DV, Patsiou V, Orfanidis A, Giannakoulas G, Kassimis G, Fragakis N, Saw J, Landmesser U, Alkhouli MA, Tzikas A. Residual leaks following percutaneous left atrial appendage occlusion and outcomes: a meta-analysis. Eur Heart J 2024; 45:214-229. [PMID: 38088437 DOI: 10.1093/eurheartj/ehad828] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 10/02/2023] [Accepted: 10/19/2023] [Indexed: 01/15/2024] Open
Abstract
BACKGROUND AND AIMS Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion. METHODS A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks. RESULTS Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52-2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08-1.24), and major bleeding (pOR 1.12, 95% CI: 1.03-1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35-2.47), 2.13 (95% CI: 1.04-4.35), 4.14 (95% CI: 2.07-8.27), and 4.44 (95% CI: 2.09-9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84-2.50 and 0.52-2.07, respectively). CONCLUSIONS Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.
Collapse
Affiliation(s)
- Athanasios Samaras
- Second Department of Cardiology, Faculty of Health Sciences, School of Medicine, General Hospital 'Hippokration', Aristotle University of Thessaloniki, Konstantinoupoleos 49, Thessaloniki 54642, Greece
| | - Andreas S Papazoglou
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Charalampos Balomenakis
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Alexandra Bekiaridou
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
- Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY, USA
| | - Dimitrios V Moysidis
- Second Department of Cardiology, Faculty of Health Sciences, School of Medicine, General Hospital 'Hippokration', Aristotle University of Thessaloniki, Konstantinoupoleos 49, Thessaloniki 54642, Greece
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vasiliki Patsiou
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
- First Department of Cardiology, Faculty of Health Sciences, School of Medicine, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Antonios Orfanidis
- Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - George Giannakoulas
- First Department of Cardiology, Faculty of Health Sciences, School of Medicine, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - George Kassimis
- Second Department of Cardiology, Faculty of Health Sciences, School of Medicine, General Hospital 'Hippokration', Aristotle University of Thessaloniki, Konstantinoupoleos 49, Thessaloniki 54642, Greece
| | - Nikolaos Fragakis
- Second Department of Cardiology, Faculty of Health Sciences, School of Medicine, General Hospital 'Hippokration', Aristotle University of Thessaloniki, Konstantinoupoleos 49, Thessaloniki 54642, Greece
| | - Jacqueline Saw
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Ulf Landmesser
- Department of Cardiology, Charité Universitätsmedizin, Berlin, Germany
| | | | - Apostolos Tzikas
- Second Department of Cardiology, Faculty of Health Sciences, School of Medicine, General Hospital 'Hippokration', Aristotle University of Thessaloniki, Konstantinoupoleos 49, Thessaloniki 54642, Greece
- European Interbalkan Medical Center, Department of Cardiology, Asklipiou 10, Pylaia, Thessaloniki 57001, Greece
| |
Collapse
|
3
|
Helal B, Khan J, AlJayar D, Khan MS, Alabdaljabar MS, Asad ZUA, DeSimone CV, Deshmukh A. Risk factors, clinical implications, and management of peridevice leak following left atrial appendage closure: A systematic review. J Interv Card Electrophysiol 2024:10.1007/s10840-023-01729-z. [PMID: 38182966 DOI: 10.1007/s10840-023-01729-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 12/26/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Left atrial appendage closure (LAAC) is a treatment modality for stroke prevention in patients with atrial fibrillation (AF). One of the potential complications of LAAC is a peri-device leak (PDL), which could potentially increase the risk of thromboembolism formation. METHODS This systematic review was done according to PRISMA guidelines. Using four databases, all primary studies through April 2022 that met selection criteria were included. Outcomes of interest were studies reporting on PDL characteristics, risk factors and management. RESULTS A total of 116 studies met selection criteria (97 original studies and 19 case reports/series). In the original studies (n = 30,133 patients), the weighted mean age was 72.0 ± 7.4 years (57% females) with a HAS-BLED and CHA2DS2-VASc weighted means of 2.8 ± 1.1 and 3.8 ± 1.3, respectively. The most common definition of PDL was based on size; 5 mm: major, 3-5 mm: moderate, < 1 mm minor, or trivial. Follow up time for PDL detection was 7.15 ± 9.0 months. 33% had PDL, irrespective of PDL severity/size, and only 0.9% had PDL of greater than 5 mm. The main risk factors for PDL development included lower degree of over-sizing, lower left ventricular ejection fraction, device/LAA shape mismatch, previous radiofrequency ablation, and male sex. The most common methods to screen for PDL included transesophageal echocardiogram and cardiac CT. PDL Management approaches include Amplatzer Patent Foramen Ovale occluder, Hookless ACP, Amplatzer vascular plug II, embolic coils, and detachable vascular coils; removal or replacement of the device; and left atriotomy. CONCLUSION Following LAAC, the emergence of a PDL is a significant complication to be aware of. Current evidence suggests possible risk factors that are worth assessing in-depth. Additional research is required to assess suitable candidates, timing, and strategies to managing patients with PDL.
Collapse
Affiliation(s)
- Baraa Helal
- College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Jibran Khan
- College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Dalia AlJayar
- College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | | | | | - Zain Ul Abideen Asad
- Department of Medicine, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | | | - Abhishek Deshmukh
- Department of Cardiovascular Medicine, 200 1St Street SW, Rochester, MN, 55905, USA.
| |
Collapse
|
4
|
Nirmalan JG, Kramer A, Korsholm K, Jensen JM, Nielsen-Kudsk JE. Computed tomography-based device-sizing in Amplatzer Amulet left atrial appendage occlusion. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01665-y. [PMID: 37882993 DOI: 10.1007/s10840-023-01665-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 10/09/2023] [Indexed: 10/27/2023]
Abstract
BACKGROUND Amplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial appendage (LAA) landing zone. However, mean, perimeter-, or area-derived diameter might be more accurate measures for device sizing. METHODS Retrospective analysis of 150 consecutive patients undergoing LAAO is guided by pre-procedural cardiac CT. A total of 117 patients were included; 7 were excluded due to renal failure and 26 due to closure with the sandwich technique. The maximum, mean, area-, and perimeter-derived diameters of the landing zone were derived from pre-procedural cardiac CT scans, and their accuracy to predict the implanted device size was investigated. The predicted device size was determined based on the currently recommended sizing algorithm. Peri-device leak (PDL) was assessed (grade 1-3) along with the underlying mechanism. RESULTS Device-sizing accuracy was superior for mean, area-, and perimeter derived diameters compared with the maximal diameter, especially for eccentric landing zones. Mean difference between predicted and actually implanted device size was 0.08 mm (± 2.77), 0.30 mm (± 2.40), - 0.39 mm (± 2.43), and - 2.55 mm (± 2.57) across mean, area-derived, perimeter-derived, and maximal diameter, respectively. Grade 3 peri-device leak was seen in 8.5% of implants without a significant association to the eccentricity of the landing zone. The leading mechanism for PDL was device malalignment. CONCLUSION Our results indicate mean, area-, and perimeter-derived diameters of the device landing zone to perform similar and superior in device-sizing accuracy compared with the maximum diameter.
Collapse
Affiliation(s)
- Jonatan Gerard Nirmalan
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, 8200, Aarhus, Denmark
| | - Anders Kramer
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, 8200, Aarhus, Denmark
| | - Kasper Korsholm
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, 8200, Aarhus, Denmark
| | - Jesper Møller Jensen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, 8200, Aarhus, Denmark
| | - Jens Erik Nielsen-Kudsk
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, 8200, Aarhus, Denmark.
| |
Collapse
|
5
|
Qi YB, Chu HM. Progress in the study and treatment of peri-device leak after left atrial appendage closure. World J Clin Cases 2023; 11:5857-5862. [PMID: 37727474 PMCID: PMC10506037 DOI: 10.12998/wjcc.v11.i25.5857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 05/28/2023] [Accepted: 08/09/2023] [Indexed: 09/01/2023] Open
Abstract
For patients with atrial fibrillation with an increased risk of stroke and contraindications to long-term anticoagulation, percutaneous left atrial appendage closure (LAAC) has become an important alternative to long-term oral anticoagulation. Incomplete closure of the LAAC during the procedure leads to faster blood flow in the interstitial space around the device, resulting in peri-device leak (PDL), which is not uncommon. Studies are still inconclusive in determining the incidence, long-term safety, and management of PDL. Therefore, this article reviewed the progress made in the research and treatment of PDL after LAAC.
Collapse
Affiliation(s)
- Ying-Bo Qi
- Department of Cardiology, Health Science Center, Ningbo University, Ningbo 315000, Zhejiang Province, China
| | - Hui-Min Chu
- Department of Cardiology, Arrhythmia Center, Ningbo First Hospital, Ningbo 3153000, Zhejiang Province, China
| |
Collapse
|
6
|
Lakkireddy D, Nielsen-Kudsk JE, Windecker S, Thaler D, Price MJ, Gambhir A, Gupta N, Koulogiannis K, Marcoff L, Mediratta A, Anderson JA, Gage R, Ellis CR. Mechanisms, predictors, and evolution of severe peri-device leaks with two different left atrial appendage occluders. Europace 2023; 25:euad237. [PMID: 37584233 PMCID: PMC10427960 DOI: 10.1093/europace/euad237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 07/18/2023] [Indexed: 08/17/2023] Open
Abstract
AIMS Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov Unique identifier NCT02879448.
Collapse
Affiliation(s)
- Dhanunjaya Lakkireddy
- Kansas City Heart Rhythm Institute and Research Foundation, 5100 W 100th St, Suite-200, Overland Park, KS 66211, USA
| | | | - Stephan Windecker
- Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | | | | | - Alok Gambhir
- Northside Hospital Cardiovascular Institute, Atlanta, GA, USA
| | - Nigel Gupta
- Los Angeles Medical Center, Los Angeles, CA, USA
| | | | - Leo Marcoff
- Cardiovascular Core Lab at Morristown Medical Center, Morristown, NJ, USA
| | - Anuj Mediratta
- Cardiovascular Core Lab at Morristown Medical Center, Morristown, NJ, USA
| | | | - Ryan Gage
- Abbott Structural Heart, Plymouth, MN, USA
| | | |
Collapse
|
7
|
He YG, Yang SH, Xu L, Wang Y, Qin XT, Chen PP, Zhao YJ. The Effect of Peri-Device Leaks on Ischaemic Stroke/Transient Ischaemic Attack/Systemic Embolism after Left Atrial Appendage Closure: A Systematic Review and Meta-Analysis. Cardiology 2023; 148:581-592. [PMID: 37459844 DOI: 10.1159/000532019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 07/10/2023] [Indexed: 12/20/2023]
Abstract
BACKGROUND Left atrial appendage closure (LAAC) is a safe and effective method for preventing embolic events in patients with non-valvular atrial fibrillation. However, peri-device leaks (PDLs) are sometimes unavoidable. Controversy exists regarding whether PDLs lead to embolic events. OBJECTIVES This study aimed to explore the association between PDLs and embolic events, including ischaemic stroke, transient ischaemic attacks (TIAs), and systemic embolism (SE). METHODS We conducted a systematic search of the PubMed, Web of Science, MEDLINE, and Cochrane Library databases for studies published up to September 25, 2022, to compare the rate of ischaemic stroke/TIA/SE between the PDL group and the non-PDL group after LAAC. RESULTS Thirteen studies comprising 54,405 patients were included in the meta-analysis. The PDL group detected by transoesophageal echocardiography (TEE) had a significantly higher rate of ischaemic stroke/TIA/SE than the non-PDL group (OR: 1.20, 95% CI: 1.08-1.33, p = 0.0009). However, no difference in ischaemic stroke/TIA/SE was found between the PDL and non-PDL subgroups of the cardiac computed tomography angiography (CCTA) group (OR: 1.12, 95% CI: 0.51-2.50, p = 0.77). CCTA and TEE showed different rates of PDL detection, with the CCTA group having a higher rate of PDL detection (p < 0.0001), especially for trivial leaks. CONCLUSIONS PDL detected by TEE increases the risk of embolic events after LAAC. However, no association was found between PDL and ischaemic stroke/TIA/SE in the CCTA group, which showed a higher rate of PDL detection than TEE, particularly for trivial leaks. In the future, CCTA may be used to explore the relationship between PDL size and ischaemic stroke/TIA/SE.
Collapse
Affiliation(s)
- Yin-Ge He
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China,
| | - Shao-Hua Yang
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| | - Liang Xu
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| | - Yan Wang
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| | - Xu-Tan Qin
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| | - Pan-Pan Chen
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| | - Yu-Jie Zhao
- Department of Cardiology, Zhengzhou No. 7 People's Hospital, Zhengzhou, China
| |
Collapse
|
8
|
Li S, Dong J, Luo J, Wang G, Xie D, Zhou L. Comparison of different quantitative evaluation protocols for peri-device leak detection using cardiac computed tomography angiography after left atrial appendage closure. Int J Cardiovasc Imaging 2023; 39:659-666. [PMID: 36329328 PMCID: PMC9947090 DOI: 10.1007/s10554-022-02748-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022]
Abstract
This study seeks to propose and compare different quantitative evaluation methods for identifying patients with peri-device leak (PDL) using cardiac computed tomography angiography (CCTA). Patients who had undergone left atrial appendage (LAA) closure and both transesophageal echocardiography (TEE) and CCTA were enrolled. Hounsfield units (HU) were measured in the proximal and distal regions of the left atrial appendage (p-LAA, d-LAA) on the CCTA, and the average of the two was determined (a-LAA). The relative HU ratios of the LAA to the center of the left atrium (LA) were calculated (p-LAA/c-LA, d-LAA/c-LA, a-LAA/c-LA). The area under the curve (AUC) for the LAA HU and the LAA/LA HU ratio were analyzed and compared. Fifty-one patients were included in this study. Pairwise comparisons showed a statistically significant difference (p = 0.029) in diagnostic performance between the d-LAA (AUC = 0.868) and a-LAA (AUC = 0.972). There were no significant differences between the a-LAA and p-LAA (p = 0.549) or between the d-LAA and p-LAA (p = 0.053). At the optimal cutoff for a-LAA of 115.5 HU, the sensitivity was 100%, the specificity was 88%. At the optimal cutoff for p-LAA of 109 HU, the sensitivity was 100%, the specificity was 84%. The LAA/LA HU ratio did not exhibit better diagnostic performance than HU attenuation in the LAA (p > 0.05). The a-LAA > 115.5 is useful in identifying PDL. Due to its convenience and intuitiveness, p-LAA > 109.0 can also be used as an alternative protocol for a-LAA.
Collapse
Affiliation(s)
- Shiqi Li
- Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006 China
| | - Jing Dong
- Department of Echocardiography, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006 China
| | - Jie Luo
- Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006 China
| | - Gaofeng Wang
- Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006 China
| | - Dujiang Xie
- Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006, China.
| | - Ling Zhou
- Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006, China.
| |
Collapse
|
9
|
Huang PS, Chiu FC, Cheng HL, Hsu JC, Chua SK, Chu CY, Lin TT, Chen JJ, Tsai CT. Peri-device leakage not CHA2DS2-VASc is associated with post-left atrial appendage closure cardiovascular event. J Stroke Cerebrovasc Dis 2022; 31:106688. [PMID: 36095860 DOI: 10.1016/j.jstrokecerebrovasdis.2022.106688] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 07/12/2022] [Accepted: 07/26/2022] [Indexed: 10/31/2022] Open
Abstract
OBJECTIVE In patients with non-valvular atrial fibrillation (NVAF), the left atrial appendage occluder (LAAO) is an alternative treatment for stroke prevention. However, thromboembolic event still occur, and the predictors are unknown. METHODS The first Asian long-term follow-up study consisted of 308 patients with mean age 71.9±9.5 years, mean CHA2DS2-VASc 4.1 ± 1.8 since 2013. Primary outcome was defined as any type of ischemic stroke/transient ischemic attack (TIA), systemic embolization and cardiovascular death. RESULTS There was no procedural-related TIA or stroke. After a mean follow-up of 38±16 months, the ischemic stroke/TIA rate was 1.9 and cardiovascular death rate 0.3 per 100 patient-year. The rate of peri-device leak (PDL) was 11.9% and device-related thrombus (DRT) 2.6%. In the multivariable analyses, PDL was the only independent predictor of stroke/TIA (hazard ratio 5.5, p=0.008). CHA2DS2-VASc score, prior history of stroke, DRT and post-procedural anti-thrombotic regimen/duration were not associated with outcomes. Implantation of Watchman was associated with PDL (odds ratio 4.35, p=0.001). CONCLUSIONS PDL is the only independent predictor of post-LAAO stroke. The risk of stroke for patients with NVAF may be controllable after LAA is occluded, because PDL is preventable and treatable.
Collapse
Affiliation(s)
- Pang-Shuo Huang
- Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital Yun-Ling Branch, Dou-Liu City, Taiwan
| | - Fu-Chun Chiu
- Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital Yun-Ling Branch, Dou-Liu City, Taiwan
| | - Hsiao-Liang Cheng
- Department of Anesthesiology, National Taiwan University College of Medicine and Hospital, Taipei, Taiwan
| | - Jung-Cheng Hsu
- Division of Cardiology, Department of Internal Medicine, Far Eastern Memorial hospital, New Taipei City, Taiwan
| | - Su-Kiat Chua
- Division of Cardiology, Department of Internal Medicine, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan
| | - Chun-Yuan Chu
- Division of Cardiology, Department of Internal Medicine, Kaohsiung Medical University Chung-Ho Memorial, Kaohsiung Taiwan
| | - Ting-Tse Lin
- Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital Hsin-Chu Branch, Hsin-Chu City, Taiwan
| | - Jien-Jiun Chen
- Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital Yun-Ling Branch, Dou-Liu City, Taiwan
| | - Chia-Ti Tsai
- Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital; Cardiovascular Center, National Taiwan University Hospital, Taipei, Taiwan.
| |
Collapse
|
10
|
Abstract
Left atrial appendage (LAA) closure has recently been approved as an alternative management for stroke prevention in patients with chronic atrial fibrillation who have difficulties with long-term oral anticoagulation. The various shapes and sizes of LAA and orientation of the atrial ostium may contribute to the incomplete LAA closure from circular design devices and orientation of the non-steerable delivery catheter. Incomplete closure of LAA leads to a high-velocity blood flow through the peri-device gap, resulting in peri-device leak (PDL). Residual leaks are frequently diagnosed after LAA closure procedures, regardless of closure methods. There is a controversy in the clinical significance of the leaks, particularly about its association with thromboembolic events. PDL <5 mm was not associated with any increase of risk for thromboembolism. Current literatures with small study population have not been sufficient to clarify the role of the leaks after LAA closure. Nevertheless, management of severe leaks has been a challenging concern for cardiologists. Leaks after epicardial LAA closures are at the neck of the incompletely closed LAA and have shown to increase the risk of thromboembolism. Percutaneous closure of the leaks after LAA closure has been attempted with good safety and success, but long-term safety and efficacy remains unclear. Further large long-term studies which aim to assess the role of leaks or PDLs in predicting thromboembolic events and management strategies are warranted.
Collapse
Affiliation(s)
- Sun-Joo Jang
- Dalio Institute of Cardiovascular Imaging, New York Presbyterian Hospital and Weill Cornell Medicine, New York, New York, USA
| | - S Chiu Wong
- Greenberg Cardiology Division, Weill Cornell Medicine, New York, New York, USA
| | - Bobak Mosadegh
- Dalio Institute of Cardiovascular Imaging, New York Presbyterian Hospital and Weill Cornell Medicine, New York, New York, USA,
| |
Collapse
|
11
|
Suradi HS, Park J, Poulin MF, Kavinsky CJ. Case report: percutaneous closure of residual leak following left atrial appendage occlusion. Eur Heart J Case Rep 2020; 4:1-4. [PMID: 32974486 PMCID: PMC7501943 DOI: 10.1093/ehjcr/ytaa139] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 12/21/2020] [Accepted: 05/01/2020] [Indexed: 11/13/2022]
Abstract
Background Transcatheter left atrial appendage occlusion (LAAO) using Watchman device has been demonstrated to be efficacious in decreasing stroke risk in patients with atrial fibrillation who are not suitable for long-term anticoagulation. Residual leaks are frequently encountered following LAAO procedures and their clinical implications and optimal management remain controversial. Case summary In this report, we describe a case of peri-Watchman device leak treated successfully with percutaneous device closure using an Amplatzer Vascular Plug II device. Discussion The clinical implications of peri-device leaks remain controversial with general consensus to continue anticoagulation along with serial imaging for larger leaks (>5 mm). As an alternative strategy, percutaneous closure of these leaks has been attempted in hope of avoiding anticoagulation and minimizing the risk of stroke and should be studied further.
Collapse
Affiliation(s)
- Hussam S Suradi
- Division of Cardiovascular Medicine, Rush University Medical Center, 1717 W. Congress Parkway, Kellogg 317, Chicago, IL 60612, USA
| | - Jeffrey Park
- Division of Cardiovascular Medicine, Rush University Medical Center, 1717 W. Congress Parkway, Kellogg 317, Chicago, IL 60612, USA
| | - Marie-France Poulin
- Division of Cardiovascular Medicine, Rush University Medical Center, 1717 W. Congress Parkway, Kellogg 317, Chicago, IL 60612, USA
| | - Clifford J Kavinsky
- Division of Cardiovascular Medicine, Rush University Medical Center, 1717 W. Congress Parkway, Kellogg 317, Chicago, IL 60612, USA
| |
Collapse
|
12
|
Fry E, Bollempali H, Suarez K, Banchs J, Michel J. Watchman outcomes comparing post-implantation anticoagulation with warfarin versus direct oral anticoagulants. J Interv Card Electrophysiol 2020; 61:137-144. [PMID: 32504227 DOI: 10.1007/s10840-020-00790-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Accepted: 05/26/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE As left atrial appendage occlusion devices (LAAO) implantation rates grow, continued evaluation on best patient practices is important. We report pooled Watchman outcomes at a multicenter Texas healthcare system with an emphasis on clinical outcomes and post-implantation anticoagulation with direct oral anticoagulants (DOACs) versus warfarin. METHODS Data for 163 patients with atrial fibrillation (AF) undergoing Watchman implantation was collected via retrospective chart review between June 2016 and June 2018. A Fisher's exact test was utilized to evaluate associations in bivariate comparisons of categorical data. Tests of non-inferiority, applied between DOACs and warfarin, utilized a ratio of 2. RESULTS Outcomes were significant for similar rates of stroke, disabling stroke, major bleeds, and all-cause mortality when compared to published clinical trials. Most patients with cerebrovascular events were found to have >5 mm peri-device leaks (PDLs), were on warfarin at the time of the event (75%), and all occurred within the first 6 months post implant. A significant number of patients were discharged on DOACs (42%). DOACs were shown to be non-inferior to warfarin with respect to stroke (p = 0.0048), disabling stroke (p = 0.0383), gastrointestinal bleeding (p = 0.0287), mortality (p = 0.0165), and combined adverse outcomes (p = 0.0040). DOACs were associated with less combined adverse outcomes (p = 0.021). CONCLUSION Our findings suggest that additional imaging or aggressive management of PDLs in Watchman recipients within the initial 6-month follow-up may aid in reducing stroke rates. Additionally, anticoagulation with DOACs' post Watchman implantation was found non-inferior to warfarin, with some evidence of lower risk for adverse outcomes favoring DOACs.
Collapse
Affiliation(s)
- Ethan Fry
- Department of Medicine, Division of Cardiology, Baylor Scott & White Health, Scott & White Memorial Hospital, 2401 S 31st Street, Temple, TX, 76508, USA.
| | - Harini Bollempali
- Department of Medicine, Baylor Scott & White Round Rock, Round Rock, TX, USA
| | - Keith Suarez
- Department of Medicine, Division of Cardiology, Baylor Scott & White Health, Scott & White Memorial Hospital, 2401 S 31st Street, Temple, TX, 76508, USA
| | - Javier Banchs
- Department of Medicine, Division of Cardiology, Baylor Scott & White Health, Scott & White Memorial Hospital, 2401 S 31st Street, Temple, TX, 76508, USA
| | - Jeffrey Michel
- Department of Medicine, Division of Cardiology, Baylor Scott & White Health, Scott & White Memorial Hospital, 2401 S 31st Street, Temple, TX, 76508, USA
| |
Collapse
|
13
|
Schneider B, Nazarenus D, Stöllberger C. A 79-year-old woman with atrial fibrillation and new onset of heart failure. ESC Heart Fail 2019; 6:570-574. [PMID: 30903653 PMCID: PMC6487709 DOI: 10.1002/ehf2.12435] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 02/26/2019] [Indexed: 12/29/2022] Open
Abstract
As an alternative to oral anticoagulation, percutaneous left atrial appendage (LAA) closure is an increasingly performed procedure to prevent arterial embolism in patients with non‐valvular atrial fibrillation. Besides procedure‐related complications, residual leaks, device‐related thrombus formation, and dislocation of the LAA occluder have been observed during follow‐up. Heart failure as a consequence of interventional LAA closure has not been reported so far. This case report describes a 79‐year‐old lady with permanent non‐valvular atrial fibrillation presenting with New York Heart Association Class IV heart failure. Symptoms had started immediately after attempted LAA closure 11 months before. Transoesophageal echocardiography demonstrated two devices in the LAA, a large peri‐device leak, a mobile LAA thrombus, a right atrial appendage thrombus, and shunting via a patent foramen ovale. Under a maximally tolerated dose of heart failure medication and edoxaban, the patient remains without bleeding or embolism in New York Heart Association Class II. Because of its unique anatomical and endocrine properties, the LAA plays an important role in situations of pressure and volume overload. Interventional LAA closure interacts unfavourably with left atrial compliance and reservoir function. Atrial and brain natriuretic peptide secretion is known to be significantly reduced after LAA closure. Both mechanisms may result in the development of heart failure. Attempted LAA closure—instead of being the solution—may create new serious problems. Development of heart failure should be assessed, and a systematic search for late leaks after LAA closure should be performed in trials investigating safety and efficacy of this intervention.
Collapse
Affiliation(s)
- Birke Schneider
- Sana Kliniken Lübeck, Kahlhorststrasse 17, Lübeck, D-23562, Germany
| | | | | |
Collapse
|
14
|
Behnes M, Akin I, Sartorius B, Fastner C, El-Battrawy I, Borggrefe M, Haubenreisser H, Meyer M, Schoenberg SO, Henzler T. --LAA Occluder View for post-implantation Evaluation (LOVE)--standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography. BMC Med Imaging 2016; 16:25. [PMID: 27009279 PMCID: PMC4806427 DOI: 10.1186/s12880-016-0127-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 03/15/2016] [Indexed: 12/16/2022] Open
Abstract
Background A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. Methods cCTA datasets were acquired on a 3rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. Results The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. Conclusions This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. Electronic supplementary material The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Michael Behnes
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
| | - Ibrahim Akin
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Benjamin Sartorius
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Christian Fastner
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Ibrahim El-Battrawy
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Martin Borggrefe
- First Department of Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Holger Haubenreisser
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Mathias Meyer
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Stefan O Schoenberg
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Thomas Henzler
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| |
Collapse
|