1
|
Modeling pulsed dye laser treatment of psoriatic plaques by combining numerical methods and image-derived lesion morphologies. Lasers Surg Med 2024. [PMID: 38576388 DOI: 10.1002/lsm.23781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/27/2024] [Accepted: 03/20/2024] [Indexed: 04/06/2024]
Abstract
OBJECTIVES Knowledge of the physical effects of pulsed dye laser (PDL) treatment of psoriatic lesions is essential in unraveling the remedial mechanisms of this treatment and hence also in maximizing in its disease-modifying potential. Therefore, the main objective of this study was to provide estimates of these physical effects (for laser wavelengths of 585 and 595 nm), with the aim of identifying pathogenic processes that may be affected by these conditions. METHODS We modeled the laser light propagation and subsequent photothermal heating by numerically solving the transient diffusion and heat equations simultaneously. To this end, we used the finite element method in conjunction with an image-derived psoriatic lesion morphology (which was defined by segmenting blood vessels from a confocal microscopy image of a fluorescently labeled section of a 3 mm punch biopsy of a psoriatic lesion). The resulting predictions of the generated temperature field within the lesion were then used to assess the possibility of stalling or arresting some suspected pathogenic processes. RESULTS According to our results, it is conceivable that perivascular nerves are thermally denatured, as almost all locations that reach 60°C were found to be within 18 µm (at 585 nm) and 11 µm (at 595 nm) of a blood vessel wall. Furthermore, activation of TRPV1 and TRPV2 channels in perivascular neuronal and immune cells is highly likely, since a critical temperature of 43°C is generated at locations within up to 350 µm of a vessel wall (at both wavelengths) and sustained for up to 700 ms (at 585 nm) and 40 ms (at 595 nm), while a critical temperature of 52°C is reached by locations within 80 µm (at 585 nm) and 30 µm (at 595 nm) of a vessel wall and sustained for up to 100 ms (at 585 nm) and 30 ms (at 595 nm). Finally, we found that the blood vessel coagulation-inducing temperature of 70°C is sustained in the vascular epithelium for up to 19 and 5 ms at 585 and 595 nm, respectively, rendering partial or total loss of vascular functionality a distinct possibility. CONCLUSIONS The presented approach constitutes a useful tool to provide realistic estimates of the photothermal effects of PDL treatment of psoriatic plaques (as well as other selective photothermolysis-based treatments), yielding information that is essential in guiding future experimental studies toward unraveling the remedial mechanisms of these treatments.
Collapse
|
2
|
Laser absorption spectroscopy measurements of different pulmonary oxygen gas concentrations in transmittance and remittance geometry: phantom study. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:115003. [PMID: 38078155 PMCID: PMC10704083 DOI: 10.1117/1.jbo.28.11.115003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/29/2023] [Accepted: 11/03/2023] [Indexed: 12/18/2023]
Abstract
Significance The gas in scattering media absorption spectroscopy (GASMAS) technique has the potential for continuous, clinical monitoring of preterm infant lung function, removing the need for X-ray diagnosis and reliance on indirect and relatively slow measurement of blood oxygenation. Aim We aim to determine the optimal source-detector configuration for reliable pathlength calculation and to estimate the oxygen gas concentration inside the lung cavities filled with humidified gas with four different oxygen gas concentrations ranging between 21% and 100%. Approach Anthropomorphic optical phantoms of neonatal thorax with two different geometries were used to acquire GASMAS signals, for 30 source-detector configurations in transmittance and remittance geometry of phantoms in two sizes. Results The results show that an internal light administration is more likely to provide a high GASMAS signal-to-noise ratio (SNR). In general, better SNRs were obtained with the smaller set of phantoms. The values of pathlength and O 2 concentrations calculated with signals from the phantoms with optical properties at 820 nm exhibit higher variations than signals from the phantoms with optical properties at 764 nm. Conclusion Our study shows that, by moving the source and detector over the thorax, most of the lung volumes can potentially be assessed using the GASMAS technique.
Collapse
|
3
|
A Monte Carlo simulation for Moving Light Source in Intracavity PDT. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2023; 12359:1235903. [PMID: 37206985 PMCID: PMC10194003 DOI: 10.1117/12.2649538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We developed a simulation method for modeling the light fluence delivery in intracavity Photodynamic Therapy (icav-PDT) for pleural lung cancer using a moving light source. Due to the large surface area of the pleural lung cavity, the light source needs to be moved to deliver a uniform dose around the entire cavity. While multiple fixed detectors are used for dosimetry at a few locations, an accurate simulation of light fluence and fluence rate is still needed for the rest of the cavity. We extended an existing Monte Carlo (MC) based light propagation solver to support moving light sources by densely sampling the continuous light source trajectory and assigning the proper number of photon packages launched along the way. The performance of Simphotek GPU CUDA-based implementation of the method - PEDSy-MC - has been demonstrated on a life-size lung-shaped phantom, custom printed for testing icav-PDT navigation system at the Perlman School of Medicine (PSM) - calculations completed under a minute (for some cases) and within minutes have been achieved. We demonstrate results within a 5% error of the analytic solution for multiple detectors in the phantom. PEDSy-MC is accompanied by a dose-cavity visualization tool that allows real-time inspection of dose values of the treated cavity in 2D and 3D, which will be expanded to ongoing clinical trials at PSM. PSM has developed a technology to measure 8-detectors in a pleural cavity phantom using Photofrin-mediated PDT that has been used during validation.
Collapse
|
4
|
Meshless Monte Carlo radiation transfer method for curved geometries using signed distance functions. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-210394SSRRR. [PMID: 35927789 PMCID: PMC9350858 DOI: 10.1117/1.jbo.27.8.083003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 07/20/2022] [Indexed: 05/18/2023]
Abstract
SIGNIFICANCE Monte Carlo radiation transfer (MCRT) is the gold standard for modeling light transport in turbid media. Typical MCRT models use voxels or meshes to approximate experimental geometry. A voxel-based geometry does not allow for the precise modeling of smooth curved surfaces, such as may be found in biological systems or food and drink packaging. Mesh-based geometry allows arbitrary complex shapes with smooth curved surfaces to be modeled. However, mesh-based models also suffer from issues such as the computational cost of generating meshes and inaccuracies in how meshes handle reflections and refractions. AIM We present our algorithm, which we term signedMCRT (sMCRT), a geometry-based method that uses signed distance functions (SDF) to represent the geometry of the model. SDFs are capable of modeling smooth curved surfaces precisely while also modeling complex geometries. APPROACH We show that using SDFs to represent the problem's geometry is more precise than voxel and mesh-based methods. RESULTS sMCRT is validated against theoretical expressions, and voxel and mesh-based MCRT codes. We show that sMCRT can precisely model arbitrary complex geometries such as microvascular vessel network using SDFs. In comparison with the current state-of-the-art in MCRT methods specifically for curved surfaces, sMCRT is more precise for cases where the geometry can be defined using combinations of shapes. CONCLUSIONS We believe that SDF-based MCRT models are a complementary method to voxel and mesh models in terms of being able to model complex geometries and accurately treat curved surfaces, with a focus on precise simulation of reflections and refractions. sMCRT is publicly available at https://github.com/lewisfish/signedMCRT.
Collapse
|
5
|
Numerical investigation of the influence of the source and detector position for optical measurement of lung volume and oxygen content in preterm infants. JOURNAL OF BIOPHOTONICS 2022; 15:e202200041. [PMID: 35340113 DOI: 10.1002/jbio.202200041] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/23/2022] [Accepted: 03/25/2022] [Indexed: 06/14/2023]
Abstract
There is an urgent need for improved respiratory surveillance of preterm infants. Gas in scattering media absorption spectroscopy (GASMAS) is emerging as a potential clinical cutaneous monitoring tool of lung functions in neonates. A challenge in the clinical translation of GASMAS is to obtain sufficiently high signal-to-noise ratios in the measurements, since the light attenuation is high in human tissue. Previous GASMAS studies on piglets have shown higher signal quality with an internal source, as more light propagates through the lung and the loss due to scattering and absorption is less. In this article we simulated light propagation with an intratracheal and a dermal source, and investigated the signal quality and lung volume probed. The results suggest that GASMAS has the potential to measure respiratory volumes; and the sensitivity is higher for an intratracheal source which also enables to probe most of the lung.
Collapse
|
6
|
Abstract
To manipulate the light-matter interaction effectively, we often rely on high refractive index inorganic nanoparticles. Such materials are contained essentially in everything that looks colorful or white: from paints to coatings but also in processed food, toothpaste, and cosmetic products. As these nanoparticles can accumulate in the human body and environment, there is a strong need to replace them with more biocompatible counterparts. In this work, we introduce various types of cellulose-based microparticles (CMPs) of four sizes with optimized dimensions for efficient light scattering that can replace traditional inorganic particles. We demonstrate that the produced materials can be exploited as highly efficient scattering enhancers, with designed optical performance. Finally, exploiting these cellulose colloids, we fabricated scattering materials and high transmittance/haze films with record performances with respect to the state-of-the-art values. The renewable and biocompatible nature of our systems, combined with their excellent optical properties, allows for the use of our cellulose-based particles in paints, LEDs, and solar cell devices and especially in applications where the biocompatibility of the component is essential, such as in food and pharmaceutical coatings.
Collapse
|
7
|
Graphics-processing-unit-accelerated Monte Carlo simulation of polarized light in complex three-dimensional media. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220009SSR. [PMID: 35534924 PMCID: PMC9084406 DOI: 10.1117/1.jbo.27.8.083015] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 04/08/2022] [Indexed: 05/18/2023]
Abstract
SIGNIFICANCE Monte Carlo (MC) methods have been applied for studying interactions between polarized light and biological tissues, but most existing MC codes supporting polarization modeling can only simulate homogeneous or multi-layered domains, resulting in approximations when handling realistic tissue structures. AIM Over the past decade, the speed of MC simulations has seen dramatic improvement with massively parallel computing techniques. Developing hardware-accelerated MC simulation algorithms that can accurately model polarized light inside three-dimensional (3D) heterogeneous tissues can greatly expand the utility of polarization in biophotonics applications. APPROACH Here, we report a highly efficient polarized MC algorithm capable of modeling arbitrarily complex media defined over a voxelated domain. Each voxel of the domain can be associated with spherical scatters of various radii and densities. The Stokes vector of each simulated photon packet is updated through photon propagation, creating spatially resolved polarization measurements over the detectors or domain surface. RESULTS We have implemented this algorithm in our widely disseminated MC simulator, Monte Carlo eXtreme (MCX). It is validated by comparing with a reference central-processing-unit-based simulator in both homogeneous and layered domains, showing excellent agreement and a 931-fold speedup. CONCLUSION The polarization-enabled MCX offers biophotonics community an efficient tool to explore polarized light in bio-tissues, and is freely available at http://mcx.space/.
Collapse
|
8
|
MCX Cloud-a modern, scalable, high-performance and in-browser Monte Carlo simulation platform with cloud computing. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-210206SSR. [PMID: 34989198 PMCID: PMC8728956 DOI: 10.1117/1.jbo.27.8.083008] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/17/2021] [Indexed: 05/06/2023]
Abstract
SIGNIFICANCE Despite the ample progress made toward faster and more accurate Monte Carlo (MC) simulation tools over the past decade, the limited usability and accessibility of these advanced modeling tools remain key barriers to widespread use among the broad user community. AIM An open-source, high-performance, web-based MC simulator that builds upon modern cloud computing architectures is highly desirable to deliver state-of-the-art MC simulations and hardware acceleration to general users without the need for special hardware installation and optimization. APPROACH We have developed a configuration-free, in-browser 3D MC simulation platform-Monte Carlo eXtreme (MCX) Cloud-built upon an array of robust and modern technologies, including a Docker Swarm-based cloud-computing backend and a web-based graphical user interface (GUI) that supports in-browser 3D visualization, asynchronous data communication, and automatic data validation via JavaScript Object Notation (JSON) schemas. RESULTS The front-end of the MCX Cloud platform offers an intuitive simulation design, fast 3D data rendering, and convenient simulation sharing. The Docker Swarm container orchestration backend is highly scalable and can support high-demand GPU MC simulations using MCX over a dynamically expandable virtual cluster. CONCLUSION MCX Cloud makes fast, scalable, and feature-rich MC simulations readily available to all biophotonics researchers without overhead. It is fully open-source and can be freely accessed at http://mcx.space/cloud.
Collapse
|
9
|
Dual-Wavelength Fluorescence Monitoring of Photodynamic Therapy: From Analytical Models to Clinical Studies. Cancers (Basel) 2021; 13:cancers13225807. [PMID: 34830963 PMCID: PMC8616416 DOI: 10.3390/cancers13225807] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/03/2021] [Accepted: 11/09/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary Fluorescence imaging is an efficient tool in monitoring photodynamic therapy procedures allowing us to track accumulation and photobleaching of a photosensitizer (PS). Chlorin-based PSs feature high absorption in the red and blue bands of visible spectrum. Due to spectral dispersion of light penetration depth in biotissues, fluorescence signals registered upon excitation by red or blue light are formed in different measurement volumes. We present analytical and numerical models of dual-wavelength fluorescence imaging for evaluation of PS localization depth in the cases of topical administration and intravenous injection. The results of analytical and numerical simulations are in good agreement with the phantom experiments, and are translated to the in vivo imaging, which allows to interpret experimental observations in animal trials, human volunteers, and clinical studies. The proposed approach allows us to noninvasively estimate typical accumulation depths of PS localization which are consistent with the morphologically expected values. Abstract Fluorescence imaging modalities are currently a routine tool for the assessment of marker distribution within biological tissues, including monitoring of fluorescent photosensitizers (PSs) in photodynamic therapy (PDT). Conventional fluorescence imaging techniques provide en-face two-dimensional images, while depth-resolved techniques require complicated tomographic modalities. In this paper, we report on a cost-effective approach for the estimation of fluorophore localization depth based on dual-wavelength probing. Owing to significant difference in optical properties of superficial biotissues for red and blue ranges of optical spectra, simultaneous detection of fluorescence excited at different wavelengths provides complementary information from different measurement volumes. Here, we report analytical and numerical models of the dual-wavelength fluorescence imaging of PS-containing biotissues considering topical and intravenous PS administration, and demonstrate the feasibility of this approach for evaluation of the PS localization depth based on the fluorescence signal ratio. The results of analytical and numerical simulations, as well as phantom experiments, were translated to the in vivo imaging to interpret experimental observations in animal experiments, human volunteers, and clinical studies. The proposed approach allowed us to estimate typical accumulation depths of PS localization which are consistent with the morphologically expected values for both topical PS administration and intravenous injection.
Collapse
|
10
|
Graphics processing unit-accelerated mesh-based Monte Carlo photon transport simulations. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-6. [PMID: 31746154 PMCID: PMC6863969 DOI: 10.1117/1.jbo.24.11.115002] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Accepted: 10/24/2019] [Indexed: 05/20/2023]
Abstract
The mesh-based Monte Carlo (MMC) algorithm is increasingly used as the gold-standard for developing new biophotonics modeling techniques in 3-D complex tissues, including both diffusion-based and various Monte Carlo (MC)-based methods. Compared to multilayered and voxel-based MCs, MMC can utilize tetrahedral meshes to gain improved anatomical accuracy but also results in higher computational and memory demands. Previous attempts of accelerating MMC using graphics processing units (GPUs) have yielded limited performance improvement and are not publicly available. We report a highly efficient MMC-MMCL-using the OpenCL heterogeneous computing framework and demonstrate a speedup ratio up to 420× compared to state-of-the-art single-threaded CPU simulations. The MMCL simulator supports almost all advanced features found in our widely disseminated MMC software, such as support for a dozen of complex source forms, wide-field detectors, boundary reflection, photon replay, and storing a rich set of detected photon information. Furthermore, this tool supports a wide range of GPUs/CPUs across vendors and is freely available with full source codes and benchmark suites at http://mcx.space/#mmc.
Collapse
|
11
|
Interstitial imaging with multiple diffusive reflectance spectroscopy projections for in vivo blood vessels detection during brain needle biopsy procedures. NEUROPHOTONICS 2019; 6:025003. [PMID: 31037243 PMCID: PMC6477697 DOI: 10.1117/1.nph.6.2.025003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Accepted: 02/20/2019] [Indexed: 05/05/2023]
Abstract
Blood vessel injury during image-guided brain biopsy poses a risk of hemorrhage. Approaches that reduce this risk may minimize related patient morbidity. We present here an intraoperative imaging device that has the potential to detect the brain vasculature in situ. The device uses multiple diffuse reflectance spectra acquired in an outward-viewing geometry to detect intravascular hemoglobin, enabling the construction of an optical image in the vicinity of the biopsy needle revealing the proximity to blood vessels. This optical detection system seamlessly integrates into a commercial biopsy system without disrupting the neurosurgical clinical workflow. Using diffusive brain tissue phantoms, we show that this device can detect 0.5-mm diameter absorptive carbon rods up to ∼ 2 mm from the biopsy window. We also demonstrate feasibility and practicality of the technique in a clinical environment to detect brain vasculature in an in vivo model system. In situ brain vascular detection may add a layer of safety to image-guided biopsies and minimize patient morbidity.
Collapse
|
12
|
Optical study of chemotherapy efficiency in cancer treatment via intracellular structural disorder analysis using partial wave spectroscopy. JOURNAL OF BIOPHOTONICS 2018; 11:e201800056. [PMID: 29869394 DOI: 10.1002/jbio.201800056] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 06/01/2018] [Indexed: 06/08/2023]
Abstract
As cancer progresses, macromolecules, such as DNA, RNA or lipids, inside cells undergo spatial structural rearrangements and alterations. Mesoscopic light transport-based optical partial wave spectroscopy (PWS) was recently introduced to quantify changes in the nanoscale structural disorder in biological cells. The PWS measurement is performed using a parameter termed as "disorder strength" (L d ), which represents the degree of nanoscale structural disorder inside the cells. It was shown that cancerous cells have higher disorder strength than normal cells. In this work, we first used the PWS to analyze the hierarchy of different types of prostate cancer cells, namely, C4-2, DU-145 and PC-3, by quantifying their average disorder strengths. Results expectedly showed that L d values increases in accordance with the increasing aggressiveness/tumorigenicity levels of these cells. Using the L d parameter, we then analyzed the chemoresistance properties of these prostate cancer cells to docetaxel drug compared to their chemosensitivity. Results show that chemoresistant cancer cells have increased L d values, that is, higher disorder strength, relative to chemosensitive cancer cells. Thus, use of the L d metric can be effective in determining the efficacy of particular chemotherapy.
Collapse
|
13
|
Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging. Phys Med Biol 2017; 62:R207-R235. [PMID: 28976914 PMCID: PMC5739055 DOI: 10.1088/1361-6560/aa8b31] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Computational modelling of radiation transport can enhance the understanding of the relative importance of individual processes involved in imaging systems. Modelling is a powerful tool for improving detector designs in ways that are impractical or impossible to achieve through experimental measurements. Modelling of light transport in scintillation detectors used in radiology and radiotherapy imaging that rely on the detection of visible light plays an increasingly important role in detector design. Historically, researchers have invested heavily in modelling the transport of ionizing radiation while light transport is often ignored or coarsely modelled. Due to the complexity of existing light transport simulation tools and the breadth of custom codes developed by users, light transport studies are seldom fully exploited and have not reached their full potential. This topical review aims at providing an overview of the methods employed in freely available and other described optical Monte Carlo packages and analytical models and discussing their respective advantages and limitations. In particular, applications of optical transport modelling in nuclear medicine, diagnostic and radiotherapy imaging are described. A discussion on the evolution of these modelling tools into future developments and applications is presented.
Collapse
|
14
|
Spatio-temporal visualization of light transport in complex photonic structures. LIGHT, SCIENCE & APPLICATIONS 2016; 5:e16090. [PMID: 30167167 PMCID: PMC6059935 DOI: 10.1038/lsa.2016.90] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 01/13/2016] [Accepted: 02/02/2016] [Indexed: 06/06/2023]
Abstract
Spatio-temporal imaging of light propagation is very important in photonics because it provides the most direct tool available to study the interaction between light and its host environment. Sub-ps time resolution is needed to investigate the fine and complex structural features that characterize disordered and heterogeneous structures, which are responsible for a rich array of transport physics that have not yet been fully explored. A newly developed wide-field imaging system enables us to present a spatio-temporal study on light transport in various disordered media, revealing properties that could not be properly assessed using standard techniques. By extending our investigation to an almost transparent membrane, a configuration that has been difficult to characterize until now, we unveil the peculiar physics exhibited by such thin scattering systems with transport features that go beyond mainstream diffusion modeling, despite the occurrence of multiple scattering.
Collapse
|
15
|
Optical tomography with discretized path integral. J Med Imaging (Bellingham) 2015; 2:033501. [PMID: 26839903 PMCID: PMC4729142 DOI: 10.1117/1.jmi.2.3.033501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Accepted: 07/10/2015] [Indexed: 08/10/2023] Open
Abstract
We present a framework for optical tomography based on a path integral. Instead of directly solving the radiative transport equations, which have been widely used in optical tomography, we use a path integral that has been developed for rendering participating media based on the volume rendering equation in computer graphics. For a discretized two-dimensional layered grid, we develop an algorithm to estimate the extinction coefficients of each voxel with an interior point method. Numerical simulation results are shown to demonstrate that the proposed method works well.
Collapse
|
16
|
Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulation. Phys Med Biol 2014; 59:2023-39. [PMID: 24694727 PMCID: PMC5524540 DOI: 10.1088/0031-9155/59/8/2023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Current developments in positron emission tomography focus on improving timing performance for scanners with time-of-flight (TOF) capability, and incorporating depth-of-interaction (DOI) information. Recent studies have shown that incorporating DOI correction in TOF detectors can improve timing resolution, and that DOI also becomes more important in long axial field-of-view scanners. We have previously reported the development of DOI-encoding detectors using phosphor-coated scintillation crystals; here we study the timing properties of those crystals to assess the feasibility of providing some level of DOI information without significantly degrading the timing performance. We used Monte Carlo simulations to provide a detailed understanding of light transport in phosphor-coated crystals which cannot be fully characterized experimentally. Our simulations used a custom reflectance model based on 3D crystal surface measurements. Lutetium oxyorthosilicate crystals were simulated with a phosphor coating in contact with the scintillator surfaces and an external diffuse reflector (teflon). Light output, energy resolution, and pulse shape showed excellent agreement with experimental data obtained on 3 × 3 × 10 mm³ crystals coupled to a photomultiplier tube. Scintillator intrinsic timing resolution was simulated with head-on and side-on configurations, confirming the trends observed experimentally. These results indicate that the model may be used to predict timing properties in phosphor-coated crystals and guide the coating for optimal DOI resolution/timing performance trade-off for a given crystal geometry. Simulation data suggested that a time stamp generated from early photoelectrons minimizes degradation of the timing resolution, thus making this method potentially more useful for TOF-DOI detectors than our initial experiments suggested. Finally, this approach could easily be extended to the study of timing properties in other scintillation crystals, with a range of treatments and materials attached to the surface.
Collapse
|
17
|
Optoacoustic imaging and tomography: reconstruction approaches and outstanding challenges in image performance and quantification. SENSORS (BASEL, SWITZERLAND) 2013; 13:7345-84. [PMID: 23736854 PMCID: PMC3715274 DOI: 10.3390/s130607345] [Citation(s) in RCA: 111] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2013] [Revised: 05/29/2013] [Accepted: 05/31/2013] [Indexed: 12/24/2022]
Abstract
This paper comprehensively reviews the emerging topic of optoacoustic imaging from the image reconstruction and quantification perspective. Optoacoustic imaging combines highly attractive features, including rich contrast and high versatility in sensing diverse biological targets, excellent spatial resolution not compromised by light scattering, and relatively low cost of implementation. Yet, living objects present a complex target for optoacoustic imaging due to the presence of a highly heterogeneous tissue background in the form of strong spatial variations of scattering and absorption. Extracting quantified information on the actual distribution of tissue chromophores and other biomarkers constitutes therefore a challenging problem. Image quantification is further compromised by some frequently-used approximated inversion formulae. In this review, the currently available optoacoustic image reconstruction and quantification approaches are assessed, including back-projection and model-based inversion algorithms, sparse signal representation, wavelet-based approaches, methods for reduction of acoustic artifacts as well as multi-spectral methods for visualization of tissue bio-markers. Applicability of the different methodologies is further analyzed in the context of real-life performance in small animal and clinical in-vivo imaging scenarios.
Collapse
|
18
|
Decoupling illumination from isosurface generation using 4D light transport. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2009; 15:1595-1602. [PMID: 19834238 PMCID: PMC4334451 DOI: 10.1109/tvcg.2009.137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
One way to provide global illumination for the scientist who performs an interactive sweep through a 3D scalar dataset is to pre-compute global illumination, resample the radiance onto a 3D grid, then use it as a 3D texture. The basic approach of repeatedly extracting isosurfaces, illuminating them, and then building a 3D illumination grid suffers from the non-uniform sampling that arises from coupling the sampling of radiance with the sampling of isosurfaces. We demonstrate how the illumination step can be decoupled from the isosurface extraction step by illuminating the entire 3D scalar function as a 3-manifold in 4-dimensional space. By reformulating light transport in a higher dimension, one can sample a 3D volume without requiring the radiance samples to aggregate along individual isosurfaces in the pre-computed illumination grid.
Collapse
|
19
|
Optimization of physiological parameter for macroscopic modeling of reacted singlet oxygen concentration in an in-vivo model. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2009; 7164:71640O. [PMID: 25995531 DOI: 10.1117/12.809024] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Singlet oxygen (1O2) is generally believed to be the major cytotoxic agent during photodynamic therapy (PDT), and the reaction between 1O2 and tumor cells define the treatment efficacy. From a complete set of the macroscopic kinetic equations which describe the photochemical processes of PDT, we can express the reacted 1O2 concentration, [1O2]rx, in a form related to time integration of the product of 1O2 quantum yield and the PDT dose rate. The production of [1O2]rx involves physiological and photophysical parameters which need to be determined explicitly for the photosensitizer of interest. Once these parameters are determined, we expect the computed [1O2]rx to be an explicit dosimetric indicator for clinical PDT. Incorporating the diffusion equation governing the light transport in turbid medium, the spatially and temporally-resolved [1O2]rx described by the macroscopic kinetic equations can be numerically calculated. A sudden drop of the calculated [1O2]rx along with the distance following the decrease of light fluence rate is observed. This suggests that a possible correlation between [1O2]rx and necrosis boundary may occur in the tumor subject to PDT irradiation. In this study, we have theoretically examined the sensitivity of the physiological parameter from two clinical related conditions: (1) collimated light source on semi-infinite turbid medium and (2) linear light source in turbid medium. In order to accurately determine the parameter in a clinical relevant environment, the results of the computed [1O2]rx are expected to be used to fit the experimentally-measured necrosis data obtained from an in vivo animal model.
Collapse
|