1
|
Early-stage use of hearing aids preserves auditory cortical structure in children with sensorineural hearing loss. Cereb Cortex 2024; 34:bhae145. [PMID: 38610087 PMCID: PMC11021813 DOI: 10.1093/cercor/bhae145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/18/2024] [Accepted: 03/20/2024] [Indexed: 04/14/2024] Open
Abstract
Hearing is critical to spoken language, cognitive, and social development. Little is known about how early auditory experiences impact the brain structure of children with bilateral sensorineural hearing loss. This study examined the influence of hearing aid use and residual hearing on the auditory cortex of children with severe to profound congenital sensorineural hearing loss. We evaluated cortical preservation in 103 young pediatric cochlear implant candidates (55 females and 48 males) by comparing their multivoxel pattern similarity of auditory cortical structure with that of 78 age-matched children with typical hearing. The results demonstrated that early-stage hearing aid use preserved the auditory cortex of children with bilateral congenital sensorineural hearing loss. Children with less residual hearing experienced a more pronounced advantage from hearing aid use. However, this beneficial effect gradually diminished after 17 months of hearing aid use. These findings support timely fitting of hearing aids in conjunction with early implantation to take advantage of neural preservation to maximize auditory and spoken language development.
Collapse
|
2
|
Benefits and risks related to cochlear implantation for children with residual hearing: a systematic review. Int J Audiol 2024; 63:75-86. [PMID: 36524877 DOI: 10.1080/14992027.2022.2155879] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 11/24/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022]
Abstract
OBJECTIVE This study aimed to synthesise information concerning the potential benefits and risks related to cochlear implants (CIs) versus hearing aids (HAs) in children with residual hearing. DESIGN A systematic review of articles published from January 2003 to January 2019 was conducted. STUDY SAMPLE Our review included studies that compared the benefits and risks of CIs versus HAs in children (≤18 years old) with residual hearing. A total of 3265 citations were identified; 8 studies met inclusion criteria. RESULTS Children with CIs showed significantly better speech perception scores post-CI than pre-CI. There was limited evidence related to improvement in everyday auditory performance, and the results showed non-significant improvement in speech intelligibility. One study on social-emotional functioning suggested benefits from CIs. In four studies, 37.2% (16/43) of children showed loss of residual hearing and 14.0% (8/57) had discontinued or limited use of their device. CONCLUSIONS Children with CIs showed improvement in speech perception outcomes compared to those with HAs. However, due to the limited number of studies and information to guide decision-making related to other areas of development, it will be important to conduct further research of both benefits and risks of CIs in this specific population to facilitate decision-making.
Collapse
|
3
|
Electrically evoked compound action potentials in cochlear implant users with preoperative residual hearing. Front Hum Neurosci 2023; 17:1125747. [PMID: 37850038 PMCID: PMC10577430 DOI: 10.3389/fnhum.2023.1125747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 09/08/2023] [Indexed: 10/19/2023] Open
Abstract
Introduction Residual hearing in cochlear implant (CI) candidates requires the functional integrity of the nerve in particular regions of the cochlea. Nerve activity can be elicited as electrically evoked compound action potentials (ECAP) after cochlear implantation. We hypothesize that ECAP thresholds depend on preoperative residual hearing ability. Materials and methods In a retrospective study, we analyzed 84 adult cochlear implant users who had received a Nucleus® CI632 Slim Modiolar Electrode and who preoperatively had had residual hearing. Inclusion criteria were severe to profound hearing loss with preoperative measurable hearing in the ear to receive the implant, postlingual hearing loss, German as native language and correct placement of the electrode, inserted completely into the scala tympani. Electrically evoked compound action potential (ECAP) was recorded intraoperatively. The angular insertion was measured for each electrode contact from postoperative computed tomography to estimate the corresponding spiral ganglion frequency. Pure-tone audiometry and allocated ECAP thresholds were tested to investigate possible correlation. Results The average of hearing thresholds, tested at 0.5, 1, 2, and 4 kHz (4FPTA) was 82 ± 18 (range 47-129) dB HL. The success rate for recording ECAP thresholds was 96.9%. For all comparable pure-tone frequencies (1, 2, 4, and 8 kHz), there was significant correlation between preoperative hearing levels and intraoperative ECAP thresholds (p < 0.001). Higher hearing thresholds are associated with increased ECAP thresholds. Conclusion In CI candidates with adequate residual hearing, intraoperative electrophysiological measurement records lower thresholds. This outcome may be explained by the neural survival density of the peripheral system, with less neural degeneration.
Collapse
|
4
|
Classification of Acoustic Hearing Preservation After Cochlear Implantation Using Electrocochleography. Trends Hear 2023; 27:23312165231220997. [PMID: 38105510 PMCID: PMC10729624 DOI: 10.1177/23312165231220997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 10/06/2023] [Accepted: 11/29/2023] [Indexed: 12/19/2023] Open
Abstract
The objective to preserve residual hearing during cochlear implantation has recently led to the use of intracochlear electrocochleography (ECochG) as an intraoperative monitoring tool. Currently, a decrease in the amplitude of the difference between responses to alternating-polarity stimuli (DIF response), predominantly reflecting the hair cell response, is used for providing feedback. Including other ECochG response components, such as phase changes and harmonic distortions, could improve the accuracy of surgical feedback. The objectives of the present study were (1) to compare simultaneously recorded stepwise intracochlear and extracochlear ECochG responses to 500 Hz tone bursts, (2) to explore patterns in features extracted from the intracochlear ECochG recordings relating to hearing preservation or hearing loss, and (3) to design support vector machine (SVM) and random forest (RF) classifiers of acoustic hearing preservation that treat each subject as a sample and use all intracochlear ECochG recordings made during electrode array insertion for classification. Forty subjects undergoing cochlear implant (CI) surgery at the Oslo University Hospital, St. Thomas' Hearing Implant Centre, or the University Hospital of Zurich were prospectively enrolled. In this cohort, DIF response amplitude decreases did not relate to postoperative acoustic hearing preservation. Exploratory analysis of the feature set extracted from the ECochG responses and preoperative audiogram showed that the features were not discriminative between outcome classes. The SVM and RF classifiers that were trained on these features could not distinguish cases with hearing loss and hearing preservation. These findings suggest that hearing loss following CI surgery is not always reflected in intraoperative ECochG recordings.
Collapse
|
5
|
Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography-A Pilot Study. J Clin Med 2022; 11:jcm11237045. [PMID: 36498620 PMCID: PMC9737018 DOI: 10.3390/jcm11237045] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 11/21/2022] [Indexed: 12/03/2022] Open
Abstract
Robotics in otology has been developing in many directions for more than two decades. Current clinical trials focus on more accurate stapes surgery, minimally invasive access to the cochlea and less traumatic insertion of cochlear implant (CI) electrode arrays. In this study we evaluated the use of the RobOtol® (Collin, Bagneux, France) otologic robot to insert CI electrodes into the inner ear with intraoperative ECochG analysis. This prospective, pilot study included two adult patients implanted with Advanced Bionics (Westinghouse PI, CA, USA) cochlear implant, with HiFocus™ Mid-Scala electrode array. The standard surgical approach was used. For both subjects, who had residual hearing in the implanted ear, intraoperative and postoperative ECochG was performed with the AIMTM system. The surgeries were uneventful. A credible ECochG response was obtained after complete electrode insertion in both cases. Preoperative BC thresholds compared to intraoperative estimated ECochG thresholds and 2-day postoperative BC thresholds had similar values at frequencies where all thresholds were measurable. The results of the ECochG performed one month after the surgery showed that in both patients the hearing residues were preserved for the selected frequencies. The RobOtol® surgical robot allows for the correct, safe and gentle insertion of the cochlear implant electrode inside the cochlea. The use of electrocochleography measurements during robotic cochlear implantation offers an additional opportunity to evaluate and modify the electrode array insertion on an ongoing basis, which may contribute to the preservation of residual hearing.
Collapse
|
6
|
Hearing preservation in cochlear implant recipients: A cross-sectional cohort study. Clin Otolaryngol 2022; 47:495-499. [PMID: 35263011 PMCID: PMC9314029 DOI: 10.1111/coa.13927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 02/04/2022] [Accepted: 02/20/2022] [Indexed: 11/27/2022]
|
7
|
Abstract
PURPOSE OF REVIEW Advancements in cochlear implant surgical approaches and electrode designs have enabled preservation of residual acoustic hearing. Preservation of low-frequency hearing allows cochlear implant users to benefit from electroacoustic stimulation, which improves performance in complex listening situations, such as music appreciation and speech understanding in noise. Despite the relative high rates of success of hearing preservation, postoperative acoustic hearing outcomes remain unpredictable. RECENT FINDINGS Thin, flexible, lateral wall arrays are preferred for hearing preservation. Both shortened and thin, lateral wall arrays have shown success with hearing preservation and the optimal implant choice is an issue of ongoing investigation. Electrocochleography can monitor cochlear function during and after insertion of the electrode array. The pathophysiology of hearing loss acutely after cochlear implant may differ from that involved in delayed hearing loss following cochlear implant. Emerging innovations may reduce cochlear trauma and improve hearing preservation. SUMMARY Hearing preservation is possible using soft surgical techniques and electrode arrays designed to minimize cochlear trauma; however, a subset of patients suffer from partial to total loss of acoustic hearing months to years following surgery despite evidence of residual apical hair cell function. Early investigations in robotic-assisted insertion and dexamethasone-eluting implants show promise.
Collapse
|
8
|
Initial Experience With a Recently Developed Lateral Wall Electrode. Laryngoscope 2021; 131:2782-2788. [PMID: 34296451 DOI: 10.1002/lary.29779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 07/07/2021] [Accepted: 07/15/2021] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To review our hearing preservation rates and speech recognition outcomes in patients undergoing cochlear implantation with a recently developed lateral wall electrode. STUDY DESIGN Retrospective cohort study. METHODS Retrospective case series of all patients, both pediatric and adult, undergoing cochlear implantation with the Advanced Bionics Hifocus™ SlimJ electrode between December 2017 and January 2020. Main outcomes included hearing preservation rates using several definitions, speech recognition testing primarily through Arizona Biosciences (AzBio) and Consonant-Nucleus-Consonant (CNC) testing, intra- and postoperative complications. RESULTS Sixty-one ears underwent implantation with the new electrode. Hearing preservation rates were 13.0% to 36.0% depending on the definition used. Speech recognition testing showed significant increases from pre- to postoperative condition (Implant-only AzBio: 24.1 to 48.3, P = .004, binaural AzBio: 46.1 to 65.9, P = .002, Implant-only CNC: 9.7 to 35.1, P < .001, binaural CNC: 29.8 to 59.40, P < .001) with last speech recognition testing occurring an average of 8.8 months postoperatively. The elderly population had the worst hearing preservation rates across all definitions. Five explantations were required due to two infections and three device failures. CONCLUSION Hearing preservation rates varied significantly depending on the definition used, but users experienced a significant improvement in speech recognition testing after implantation. More work is needed in the community to standardize the definition of residual hearing and hearing preservation. LEVEL OF EVIDENCE 4 Laryngoscope, 2021.
Collapse
|
9
|
Interaction Between Electric and Acoustic Stimulation Influences Speech Perception in Ipsilateral EAS Users. Ear Hear 2021; 41:868-882. [PMID: 31592902 PMCID: PMC7676483 DOI: 10.1097/aud.0000000000000807] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 08/30/2019] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to determine electric-acoustic masking in cochlear implant users with ipsilateral residual hearing and different electrode insertion depths and to investigate the influence on speech reception. The effects of different fitting strategies-meet, overlap, and a newly developed masking adjusted fitting (UNMASKfit)-on speech reception are compared. If electric-acoustic masking has a detrimental effect on speech reception, the individualized UNMASKfit map might be able to reduce masking and thereby enhance speech reception. DESIGN Fifteen experienced MED-EL Flex electrode recipients with ipsilateral residual hearing participated in a crosssover design study using three fitting strategies for 4 weeks each. The following strategies were compared: (1) a meet fitting, dividing the frequency range between electric and acoustic stimulation, (2) an overlap fitting, delivering part of the frequency range both acoustically and electrically, and (3) the UNMASKfit, reducing the electric stimulation according to the individual electric-on-acoustic masking strength. A psychoacoustic masking procedure was used to measure the changes in acoustic thresholds due to the presence of electric maskers. Speech reception was measured in noise with the Oldenburg Matrix Sentence test. RESULTS Behavioral thresholds of acoustic probe tones were significantly elevated in the presence of electric maskers. A maximum of masking was observed when the difference in location between the electric and acoustic stimulation was around one octave in place frequency. Speech reception scores and strength of masking showed a dependency on residual hearing, and speech reception was significantly reduced in the overlap fitting strategy. Electric- acoustic stimulation significantly improved speech reception over electric stimulation alone, with a tendency toward a larger benefit with the UNMASKfit map. In addition, masking was significantly inversely correlated to the speech reception performance difference between the overlap and the meet fitting. CONCLUSIONS (1) This study confirmed the interaction between ipsilateral electric and acoustic stimulation in a psychoacoustic masking experiment. (2) The overlap fitting yielded poorer speech reception performance in stationary noise especially in subjects with strong masking. (3) The newly developed UNMASKfit strategy yielded similar speech reception thresholds with an enhanced acoustic benefit, while at the same time reducing the electric stimulation. This could be beneficial in the long-term if applied as a standard fitting, as hair cells are exposed to less possibly adverse electric stimulation. In this study, the UNMASKfit allowed the participants a better use of their natural hearing even after 1 month of adaptation. It might be feasible to transfer these results to the clinic, by fitting patients with the UNMASKfit upon their first fitting appointment, so that longer adaptation times can further improve speech reception.
Collapse
|
10
|
Simultaneous Intra- and Extracochlear Electrocochleography During Cochlear Implantation to Enhance Response Interpretation. Trends Hear 2021; 25:2331216521990594. [PMID: 33710919 PMCID: PMC7958165 DOI: 10.1177/2331216521990594] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
The use of electrocochleography (ECochG) for providing real-time feedback of
cochlear function during cochlear implantation is receiving increased attention
for preventing cochlear trauma and preserving residual hearing. Although various
studies investigated the relationship between intra-operative ECochG
measurements and surgical outcomes in recent years, the limited interpretability
of ECochG response changes leads to conflicting study results and prevents the
adoption of this method for clinical use. Specifically, the movement of the
recording electrode with respect to the different signal generators in
intracochlear recordings makes the interpretation of signal changes with respect
to cochlear trauma difficult. Here, we demonstrate that comparison of ECochG
signals recorded simultaneously from intracochlear locations and from a fixed
extracochlear location can potentially allow a differentiation between traumatic
and atraumatic signal changes in intracochlear recordings. We measured ECochG
responses to 500 Hz tone bursts with alternating starting phases during cochlear
implant insertions in six human cochlear implant recipients. Our results show
that an amplitude decrease with associated near 180° phase shift and harmonic
distortions in the intracochlear difference curve during the first half of
insertion was not accompanied by a decrease in the extracochlear difference
curve’s amplitude (n = 1), while late amplitude decreases in
intracochlear difference curves (near full insertion, n = 2)
did correspond to extracochlear amplitude decreases. These findings suggest a
role for phase shifts, harmonic distortions, and recording location in
interpreting intracochlear ECochG responses.
Collapse
|
11
|
Clinical characteristics and outcomes of children with cochlear implants who had preoperative residual hearing. Int J Audiol 2021; 61:108-118. [PMID: 33761807 DOI: 10.1080/14992027.2021.1893841] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Cochlear implants (CI) candidacy criteria have expanded to include children with more residual hearing. This study explored the clinical profiles and outcomes of children with CIs who had preoperative residual hearing in at least one ear. DESIGN A retrospective chart review was conducted to collect clinical characteristics and speech perception data. Pre- and post-CI auditory and speech perception data were analysed using a modified version of the Pediatric Ranked Order Speech Perception (PROSPER) score. STUDY SAMPLE This study included all children with residual hearing who received CIs in one Canadian paediatric centre from 1992 to 2018. RESULTS A total of 100 of 389 (25.7%) children with CIs had residual hearing (median 77.6 dB HL, better ear). The proportion of children with residual hearing increased from 1992 to 2018. Children who had auditory behaviour and speech perception tests (n = 83) showed higher modified PROSPER scores post-CI compared to pre-CI. Phonologically Balanced Kindergarten (PBK) test scores were available for 71 children post-CI; 81.7% (58/71) of children achieved > 80% on the PBK. CONCLUSIONS One in four children who received CIs had residual hearing, and most of them had severe hearing loss at pre-CI. These children showed a high level of speech perception with CIs.
Collapse
|
12
|
Abstract
BACKGROUND Mutations in the TMPRSS3 gene, although rare, can cause high frequency hearing loss with residual hearing at low frequencies. Several previous studies have reported cochlear implant (CI) outcomes for adults with TMPRSS3 mutation with mixed results. Although some studies have suggested that TMPRSS3 is expressed in spiral ganglion cells, it remains unclear if previously reported poor CI outcomes in this population were secondary to long durations of deafness or to the effects of the TMPRSS3 mutation. To date, no studies in the literature have reported CI outcomes for children with TMPRSS3 mutation treated with CI. OBJECTIVE The current case series aimed to describe outcomes for three children with sloping hearing loss caused by TMPRSS3 mutation who underwent bilateral CI. STUDY DESIGN Case series. SETTING Academic medical center. PATIENTS Three children (3-4 yr) with TMPRSS3 mutation and normal sloping to profound high frequency hearing loss. INTERVENTIONS CI and electric acoustic stimulation (EAS). MAIN OUTCOME MEASURES Outcome measures were residual hearing thresholds, speech recognition scores, and electrode placement determined via intraoperative CT imaging. RESULTS All three children maintained residual acoustic hearing and received benefit from EAS. Mean change in low-frequency pure-tone average was 17 dB. Mean postoperative word and sentence recognition scores in the bilateral EAS condition were 80 and 75%, respectively. CONCLUSIONS Results indicate that CI with EAS is an appropriate treatment for children with TMPRSS3 genetic mutation. Pediatric results from this case series show more favorable CI outcomes than are currently reported for adults with TMPRSS3 mutation suggesting that the intervention may be time sensitive.
Collapse
|
13
|
Cochlear implantation in a patient with a POU4F3 mutation. Clin Case Rep 2021; 9:298-303. [PMID: 33489177 PMCID: PMC7813023 DOI: 10.1002/ccr3.3520] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 10/12/2020] [Accepted: 10/24/2020] [Indexed: 11/21/2022] Open
Abstract
Cochlear implants (CIs) are generally considered useful in the treatment of hereditary hearing loss with progressive deafness. Early CI can be beneficial for maintaining social activities in POU4F3 mutation patients.
Collapse
|
14
|
Electrocochleography in Cochlear Implant Users with Residual Acoustic Hearing: A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17197043. [PMID: 32993065 PMCID: PMC7579537 DOI: 10.3390/ijerph17197043] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 09/18/2020] [Accepted: 09/24/2020] [Indexed: 11/16/2022]
Abstract
(1) Objectives: This study reviews the use of electrocochleography (ECoG) as a tool for assessing the response of the peripheral auditory system and monitoring hearing preservation in the growing population of cochlear implant (CI) users with preserved hearing in the implanted ear. (2) Methods: A search was conducted in PubMed and CINAHL databases up to August 2020 to locate articles related to the ECoG measured during or after the cochlear implant (CI) surgery for monitoring purposes. Non-English articles, animal studies, literature reviews and editorials, case reports, and conference papers were excluded. The quality of studies was evaluated using the National Institute of Health (NIH) "Study Quality Assessment Tool for Case Series Studies". (3) Results: A total 30 articles were included for the systematic review. A total of 21 articles were intraoperative ECoG studies, while seven articles were postoperative studies. Two studies were conducted ECoG both during and after the surgery. Intraoperative ECoG studies focused on monitoring changes in ECoG response amplitudes during and/or after electrode insertion and predicting the scalar location of the electrode array. Postoperative ECoG studies focused on using the ECoG measurements to estimate behavioral audiometric thresholds and monitor pathophysiological changes related to delayed onset hearing loss postimplant. (4) Conclusions: ECoG is feasible to provide real-time feedback intraoperatively and has a potential clinical value to monitor the status of hearing preservation postoperatively in this CI population with residual acoustic hearing.
Collapse
|
15
|
Electric-acoustic stimulation with longer electrodes for potential deterioration in low-frequency hearing. Acta Otolaryngol 2020; 140:632-638. [PMID: 32498646 DOI: 10.1080/00016489.2020.1760351] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background: Electric-acoustic stimulation (EAS) has emerged as a standard treatment for patients with high-frequency hearing loss. EAS is usually performed with shorter electrodes of 16-24 mm in length. As most EAS recipients gradually lose residual acoustic hearing in the implanted ear over time, EAS with longer electrodes without causing significant intra-cochlear damage might be ideal.Objective: The aim of this study was to investigate hearing preservation (HP) results after EAS surgery with longer electrodes.Methods: Ten patients (11 ears) with partial deafness that met the indications for EAS with a MED-EL FLEX28 electrode were included in this study. Auditory thresholds before and at 6 months after activation were examined.Results: In 100% of cases, HP was comfortably achieved, indicating that all patients could utilize acoustic amplification combined with electric stimulation.Conclusion: EAS with longer electrodes can offer broader cochlear coverage, resulting in natural frequency matching in comparison with shorter electrodes, even in EAS cases. The combination of advanced surgical techniques and flexible, long, straight electrodes permits deep insertion that reaches the apical region with little or no insertion trauma.
Collapse
|
16
|
Genetic testing has the potential to impact hearing preservation following cochlear implantation. Acta Otolaryngol 2020; 140:438-444. [PMID: 32134349 DOI: 10.1080/00016489.2020.1730439] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background: Recent advances in less-invasive surgery and electrode design allow for a high degree of hearing preservation (HP) after cochlear implantation (CI), although residual hearing still deteriorates in some patients. To date, the factors predictive of preserving residual hearing remain a controversial topic.Objective: The aim of this study was to investigate the predictive factors, including the etiology of hearing loss (HL) as a patient-related factor, influencing residual HP after CI.Methods: Forty-four patients (50 ears, 41 families) with residual acoustic hearing who underwent CI were included. Auditory thresholds before and at 6 months after initial activation were measured. Genetic testing was performed to identify the responsible genes for HL.Results: We identified the cause of HL in 21 families (51.2%). HP was marginally correlated with age at implantation, while it was independent of pre-operative low-frequency hearing thresholds, cochlear duct length, and electrode length. We found that patients who had pathogenic variants in the CDH23, MYO7A, or MYO15A gene showed statistically better HP scores compared with patients with HL due to other causes (p = .002).Conclusions: Identification of the etiology of HL using genetic testing is likely to facilitate the prediction of HP after implant surgery.
Collapse
|
17
|
Nucleus Hybrid S12: Multicenter Clinical Trial Results. Laryngoscope 2020; 130:E548-E558. [PMID: 32212342 DOI: 10.1002/lary.28628] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 01/07/2020] [Accepted: 03/05/2020] [Indexed: 11/05/2022]
Abstract
OBJECTIVES/HYPOTHESIS The use of a short 10-mm/10-electrode cochlear implant to preserve low-frequency residual hearing was investigated. This report describes the 12-month outcomes of this multicenter clinical trial. STUDY DESIGN Single-subject design. METHODS Twenty-eight subjects with low-frequency hearing at or better than 60 dB HL at 500 Hz and severe high-frequency hearing loss were implanted with a Nucleus Hybrid S12 implant in their poorer ear. Speech perception in quiet using Consonant-Nucleus-Consonant (CNC) words and sentences in noise using AzBio sentences was collected pre- and postoperatively at 3, 6, and 12 months. Subjective reporting using the Speech, Spatial, and Qualities of Hearing Scale (SSQ) questionnaire was also collected pre- and postoperatively. RESULTS Functional hearing preservation was accomplished in 96% of subjects. At 3 and 6 months, 86% of the 28 subjects had maintained functional hearing. By 12 months, 23 out of 27 subjects (85%) had maintained functional hearing (one subject with functional hearing at 6 months withdrew from the study prior to the 12-month visit). Speech perception results demonstrated that 81% of the participants on CNC words and 77% with AzBio sentences in noise had significant improvements using their everyday listening condition at 12 months compared to preoperative performance with bilateral hearing aids. Furthermore, preoperative to 12 months postoperative subjective ratings showed significant improvements for the SSQ. CONCLUSIONS This study demonstrates that a high degree of hearing preservation enabling acoustic-electric hearing and improvement in speech understanding in quiet and in noise can be accomplished using a short-electrode 10-mm cochlear implant. LEVEL OF EVIDENCE 2c Laryngoscope, 130:E548-E558, 2020.
Collapse
|
18
|
Evaluating the Efficacy of L-N-acetylcysteine and Dexamethasone in Combination to Provide Otoprotection for Electrode Insertion Trauma. J Clin Med 2020; 9:jcm9030716. [PMID: 32155788 PMCID: PMC7141216 DOI: 10.3390/jcm9030716] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 02/27/2020] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Electrode insertion trauma (EIT) during cochlear implantation (CI) can cause loss of residual hearing. L-N-acetylcysteine (L-NAC) and dexamethasone (Dex) have been individually shown to provide otoprotection albeit at higher concentrations that may be associated with adverse effects. Objective/Aims: The aim of this study is to determine whether L-NAC and Dex could be combined to decrease their effective dosage. MATERIALS AND METHODS The organ of Corti (OC) explants were divided into various groups: 1) control; 2) EIT; 3) EIT treated with different concentrations of Dex; 4) EIT treated with different concentrations of L-NAC; 5) EIT treated with L-NAC and Dex in combination. Hair cell (HC) density, levels of oxidative stress, proinflammatory cytokines and nitric oxide (NO) was determined. RESULTS There was a significant loss of HCs in explants subjected to EIT compared to the control group. L-NAC and Dex in combination was able to provide significant otoprotection at lower concentrations compared to individual drugs. CONCLUSIONS AND SIGNIFICANCE A combination containing L-NAC and Dex is effective in protecting sensory cells at lower protective doses than each compound separately. These compounds can be combined allowing a decrease of potential side effects of each compound and providing significant otoprotection for EIT.
Collapse
|
19
|
Abstract
INTRODUCTION Surgical treatment of deafness by cochlear implants is used for more than 40 years, and during this period permanently, gradual and significant expansion of indications for this surgery has been observed. MATERIAL AND METHODS In our Department in the years 1994-2018 1480 cochlear implantations were performed, both in adults (647) and in children (883). In this study current indications and the rules for eligibility of patients based on 25 years of experience are presented. RESULTS Indications for cochlear implantation in adults are: 1) bilateral postlingual deafness, 2) bilateral sensorineural hearing loss - in pure tone audiometry > 70 dB HL (average 500-4000 Hz) and in speech audiometry in hearing aids understanding < 50% of words for the intensity of the stimulus 65 dB, in the absence of the benefits of hearing aids, 3) bilateral profound hearing loss for high frequency with good hearing for low frequency, in the absence of the benefits of hearing aids, 4) some cases of asymmetric hearing loss with intensive tinnitus in the deaf ear. An indication in children is bilateral sensorineural hearing loss > 80dB HL confirmed by hearing tests, after about 6 months of rehabilitation with the use of hearing aids. DISCUSSION Although cochlear implantation is used for more than 40 years, the indications for this treatment underlies constant modifications. They concern the age of eligible patients, implantation in patients with partially preserved hearing, as well as treatment for patients with difficult anatomical conditions. In many countries, bilateral implantations are commonly performed, and more and more centers recommend this treatment in the case of unilateral deafness or asymmetric hearing loss, especially with the accompanying tinnitus in the deaf ear.
Collapse
|
20
|
Effects of Low Frequency Residual Hearing on Music Perception and Psychoacoustic Abilities in Pediatric Cochlear Implant Recipients. Front Neurosci 2019; 13:924. [PMID: 31551687 PMCID: PMC6733978 DOI: 10.3389/fnins.2019.00924] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 08/19/2019] [Indexed: 12/02/2022] Open
Abstract
Studies have demonstrated the benefits of low frequency residual hearing in music perception and for psychoacoustic abilities of adult cochlear implant (CI) users, but less is known about these effects in the pediatric group. Understanding the contribution of combined electric and acoustic stimulation in this group can help to gain a better perspective on decisions regarding bilateral implantation. We evaluated the performance of six unilaterally implanted children between 9 and 13 years of age with contralateral residual hearing using the Clinical Assessment of Music Perception (CAMP), spectral ripple discrimination (SRD), and temporal modulation transfer function (TMTF) tests and compared findings with previous research. Our study sample performed similarly to normal hearing subjects in pitch direction discrimination (0.81 semitones) and performed well above typical CI users in melody recognition (43.37%). The performance difference was less in timbre recognition (48.61%), SRD (1.47 ripple/octave), and TMTF for four modulation frequencies. These findings suggest that the combination of low frequency acoustic hearing with the broader frequency range of electric hearing can help to increase clinical CI benefit in pediatric users and decisions regarding second-side implantation should consider these factors.
Collapse
|
21
|
An Individual With Hearing Preservation and Bimodal Hearing Using a Cochlear Implant and Hearing Aids Has Perturbed Sound Localization but Preserved Speech Perception. Front Neurol 2019; 10:637. [PMID: 31293495 PMCID: PMC6598447 DOI: 10.3389/fneur.2019.00637] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Accepted: 05/30/2019] [Indexed: 11/13/2022] Open
Abstract
This study describes sound localization and speech-recognition-in-noise abilities of a cochlear-implant user with electro-acoustic stimulation (EAS) in one ear, and a hearing aid in the contralateral ear. This listener had low-frequency, up to 250 Hz, residual hearing within the normal range in both ears. The objective was to determine how hearing devices affect spatial hearing for an individual with substantial unaided low-frequency residual hearing. Sound-localization performance was assessed for three sounds with different bandpass characteristics: low center frequency (100-400 Hz), mid center frequency (500-1,500 Hz) and high frequency broad-band (500-20,000 Hz) noise. Speech recognition was assessed with the Dutch Matrix sentence test presented in noise. Tests were performed while the listener used several on-off combinations of the devices. The listener localized low-center frequency sounds well in all hearing conditions, but mid-center frequency and high frequency broadband sounds were localized well almost exclusively in the completely unaided condition (mid-center frequency sounds were also localized well with the EAS device alone). Speech recognition was best in the fully aided condition with speech presented in the front and noise presented at either side. Furthermore, there was no significant improvement in speech recognition with all devices on, compared to when the listener used her cochlear implant only. Hearing aids and cochlear implant impair high frequency spatial hearing due to improper weighing of interaural time and level difference cues. The results reinforce the notion that hearing symmetry is important for sound localization. The symmetry is perturbed by the hearing devices for higher frequencies. Speech recognition depends mainly on hearing through the cochlear implant and is not significantly improved with the added information from hearing aids. A contralateral hearing aid provides benefit when the noise is spatially separated from the speech. However, this benefit is explained by the head shadow in that ear, rather than by an ability to spatially segregate noise from speech, as sound localization was perturbed with all devices in use.
Collapse
|
22
|
Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography. Front Neurosci 2018; 12:18. [PMID: 29434534 PMCID: PMC5790789 DOI: 10.3389/fnins.2018.00018] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 01/10/2018] [Indexed: 11/24/2022] Open
Abstract
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle electrode placed on the promontory; for intracochlear ECoG recordings, the most apical contact of the cochlear implant (CI) electrode itself was used as the recording electrode. Tone bursts at 250, 500, 750, and 1000 Hz were used as low-frequency acoustic stimuli and clicks as high-frequency acoustic stimuli. Changes of extracochlear ECoG recordings after full insertion of the CI electrode were correlated with pure-tone audiometric findings 4 weeks after surgery. Results: Changes in extracochlear ECoG recordings correlated with postoperative hearing change (r = −0.44, p = 0.055, n = 20). Mean hearing loss in subjects without decrease or loss of extracochlear ECoG signals was 12 dB, compared to a mean hearing loss of 22 dB in subjects with a detectable decrease or a loss of ECoG signals (p = 0.0058, n = 51). In extracochlear ECoG recordings, a mean increase of the ECoG signal of 4.4 dB occurred after opening the cochlea. If a decrease of ECoG signals occurred during insertion of the CI electrode, the decrease was detectable during the second half of the insertion. Conclusion: ECoG recordings allow detection of electrophysiological changes in the cochlea during cochlear implantation. Decrease of extracochlear ECoG recordings during surgery has a significant correlation with hearing loss 4 weeks after surgery. Trauma to cochlear structures seems to occur during the final phase of the CI electrode insertion. Baseline recordings for extracochlear ECoG recordings should be conducted after opening the cochlea. ECoG responses can be recorded from an intracochlear site using the CI electrode as recording electrode. This technique may prove useful for monitoring cochlear trauma intraoperatively in the future.
Collapse
|
23
|
Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography. Front Neurosci 2018. [PMID: 29434534 DOI: 10.3389/fnins.2018.00018/bibtex] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/24/2023] Open
Abstract
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle electrode placed on the promontory; for intracochlear ECoG recordings, the most apical contact of the cochlear implant (CI) electrode itself was used as the recording electrode. Tone bursts at 250, 500, 750, and 1000 Hz were used as low-frequency acoustic stimuli and clicks as high-frequency acoustic stimuli. Changes of extracochlear ECoG recordings after full insertion of the CI electrode were correlated with pure-tone audiometric findings 4 weeks after surgery. Results: Changes in extracochlear ECoG recordings correlated with postoperative hearing change (r = -0.44, p = 0.055, n = 20). Mean hearing loss in subjects without decrease or loss of extracochlear ECoG signals was 12 dB, compared to a mean hearing loss of 22 dB in subjects with a detectable decrease or a loss of ECoG signals (p = 0.0058, n = 51). In extracochlear ECoG recordings, a mean increase of the ECoG signal of 4.4 dB occurred after opening the cochlea. If a decrease of ECoG signals occurred during insertion of the CI electrode, the decrease was detectable during the second half of the insertion. Conclusion: ECoG recordings allow detection of electrophysiological changes in the cochlea during cochlear implantation. Decrease of extracochlear ECoG recordings during surgery has a significant correlation with hearing loss 4 weeks after surgery. Trauma to cochlear structures seems to occur during the final phase of the CI electrode insertion. Baseline recordings for extracochlear ECoG recordings should be conducted after opening the cochlea. ECoG responses can be recorded from an intracochlear site using the CI electrode as recording electrode. This technique may prove useful for monitoring cochlear trauma intraoperatively in the future.
Collapse
|
24
|
Feasibility of Using Electrocochleography for Objective Estimation of Electro-Acoustic Interactions in Cochlear Implant Recipients with Residual Hearing. Front Neurosci 2017; 11:337. [PMID: 28674482 PMCID: PMC5475389 DOI: 10.3389/fnins.2017.00337] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 05/29/2017] [Indexed: 11/18/2022] Open
Abstract
Although cochlear implants (CI) traditionally have been used to treat individuals with bilateral profound sensorineural hearing loss, a recent trend is to implant individuals with residual low-frequency hearing. Patients who retain some residual acoustic hearing after surgery often can benefit from electro-acoustic stimulation (EAS) technologies, which combine conventional acoustic amplification with electrical stimulation. However, interactions between acoustic and electrical stimulation may affect outcomes adversely and are time-consuming and difficult to assess behaviorally. This study demonstrated the feasibility of using the Advanced Bionics HiRes90K Advantage implant electronics and HiFocus Mid Scala/1j electrode to measure electrocochleography (ECochG) responses in the presence of electrical stimulation to provide an objective estimate of peripheral physiologic EAS interactions. In general, electrical stimulation reduced ECochG response amplitudes to acoustic stimulation. The degree of peripheral EAS interaction varied as a function of acoustic pure tone frequency and the intra-cochlear location of the electrically stimulated electrode. Further development of this technique may serve to guide and optimize clinical EAS system fittings in the future.
Collapse
|
25
|
Abstract
Objective Evaluate if electrode design affects hearing preservation (HP) following cochlear implantation (CI) with full-length electrodes. Study Design Case series with chart review. Setting Tertiary referral academic center. Subjects and Methods Forty-five adults with low-frequency hearing (≤85 dB at 250 and 500 Hz) who underwent unilateral CI with full-length electrode arrays made by 1 manufacturer were included. HP was calculated with (1) mean low-frequency pure-tone average (LFPTA) at 250 and 500 Hz (MEAN method), (2) a percentile method across the audiometric frequency spectrum generating an S-value (HEARRING method), and (3) functional if hearing remained ≤85 dB at 250 and 500 Hz. Audiometric testing was performed approximately 1 month and 1 year postoperatively, yielding short-term and long-term results, respectively. Results Of 45 patients who underwent CI, 46.7% received lateral wall (LW) and 53.3% received perimodiolar (PM) electrodes. At short-term follow-up, LW electrodes were associated with significantly better HP than PM (LFPTA method: 27.7 vs 39.3 dB, P < .05; S-value method: 48.2 vs 21.8%, P < .05). In multivariate regression of short-term outcomes, LW electrode use was a significant predictor of better HP ( P < .05). At long-term follow-up, electrode type was not associated with HP. Younger patient age was the only significant predictor of long-term HP on multivariate analysis ( P < .05). Conclusion The LW electrode is associated with short-term HP, suggesting its design is favorable for limiting trauma to the cochlea during and directly following CI. Other factors, including age, are relevant for maintaining HP over the long term. The data support further investigation into what modifiable factors may promote long-term HP.
Collapse
|
26
|
Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation. Front Neurosci 2017; 11:291. [PMID: 28611574 PMCID: PMC5447029 DOI: 10.3389/fnins.2017.00291] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 05/08/2017] [Indexed: 11/13/2022] Open
Abstract
Introduction: The objectives of the current study were to (1) determine the relationship between electrocochleography (ECochG), measured from the cochlear implant (CI) electrode array during and after implantation, and postoperative audiometric thresholds, (2) determine the relationship between ECochG amplitude and electrode scalar location determined by computerized tomography (CT); and (3) determine whether changes in cochlear microphonic (CM) amplitude during electrode insertion were associated with postoperative hearing. Materials and Methods: Eighteen subjects undergoing CI with an Advanced Bionics Mid-Scala device were prospectively studied. ECochG responses were recorded using the implant coupled to a custom signal recording unit. ECochG amplitude collected intraoperatively concurrent with CI insertion and at activation was compared with audiometric thresholds postoperatively. Sixteen patients also underwent postoperative CT to determine scalar location and the relationship to ECochG measures and residual hearing. Results: Mean low-frequency pure tone average (LFPTA) increased following surgery by an average of 28 dB (range 8–50). Threshold elevation was significantly greater for electrodes with scalar dislocation. No correlation was found between intraoperative ECochG and postoperative behavioral thresholds collapsed across frequency; however, mean differences in thresholds measured by intraoperative ECochG and postoperative audiometry were significantly smaller for electrodes inserted completely within scala tympani (ST) vs. those translocating from ST to scala vestibuli. A significant correlation was observed between postoperative ECochG thresholds and behavioral thresholds obtained at activation. Discussion: Postoperative audiometry currently serves as a marker for intracochlear trauma though thresholds are not obtained until device activation or later. When measured at the same time-point postoperatively, low-frequency ECochG thresholds correlated with behavioral thresholds. Intraoperative ECochG thresholds, however, did not correlate significantly with postoperative behavioral thresholds suggesting that changes in cochlear physiology occur between electrode insertion and activation. ECochG may hold clinical utility providing surgeons with feedback regarding insertion trauma due to scalar translocation, which may be predictive of postoperative hearing preservation. Conclusion: CI insertion trauma is generally not evident until postoperative audiometry when loss of residual hearing is confirmed. ECochG has potential to provide estimates of trauma during insertion as well as reliable information regarding degree of hearing preservation.
Collapse
|
27
|
Acoustic plus electric speech processing: Long-term results. Laryngoscope 2017; 128:473-481. [PMID: 28543270 DOI: 10.1002/lary.26669] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 03/31/2017] [Accepted: 04/12/2017] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Few studies have investigated the stability of residual hearing and speech perception outcomes in individuals who were implanted with a shorter electrode device. STUDY DESIGN Longitudinal, single-subject design. METHODS Fifty subjects who received a Nucleus Hybrid (Cochlear, Sydney, Australia) short electrode cochlear implant (CI) and had a minimum of 2 years (and up to 15 years) of postoperative longitudinal experience were included in this study. Twenty-three subjects received a Nucleus Hybrid S8 (S8); 14 subjects received a Nucleus Hybrid L24 (L24); and 13 received a Nucleus Hybrid S12 (S12). Audiometric thresholds and consonant-nucleus-consonant (CNC) words were collected pre- and postoperatively for up to 15 years for the S8 subjects and for up to 7 years for the S12 and L24 subjects. AzBio Sentences in multi-talker babble was collected for up to 7 years on the S12 and L24 subjects. RESULTS Longitudinally, 83% of the S8 subjects, 92% of the S12 subjects, and 86% of the L24 subjects maintained a functional hearing pure-tone average (PTA) (125-500 Hz). Predicted change using a piecewise linear mixed model in PTA over time showed a postoperative linear decrease in hearing for each group until 0.5 years, after which the PTA stabilizes and is maintained. The averaged individual data for CNC and AzBio sentences show a significant improvement in scores by 0.25 to 0.5 years postimplantation, after which scores start to reach their maximum. CONCLUSION This long-term study demonstrates that acoustic-electric processing hearing and improvement in speech understanding in quiet and in noise can be accomplished and sustained for many years with a short electrode CI. LEVEL OF EVIDENCE 2C. Laryngoscope, 128:473-481, 2018.
Collapse
|
28
|
Insertional depth-dependent intracochlear pressure changes in a model of cochlear implantation. Acta Otolaryngol 2017; 137:113-118. [PMID: 27575779 DOI: 10.1080/00016489.2016.1219918] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
CONCLUSION Over time, a homogenous increase in intracochlear pressure was seen in every experiment. Significant reductions in terms of amplitude variation and insertion depth were observed over time, using the one-point-supported insertion method. The frequency of peaks between the thirds was significantly lower when using the two-points-supported insertion method. OBJECTIVES The preservation of residual hearing and minimization of intracochlear trauma are two of the major goals in modern cochlear implantation (CI) surgery. It is assumed that intracochlear pressure measurements yield information about the intracochlear behavior of the electrode itself in the cochlea. The aim of this study was to investigate temporal intracochlear fluid pressure changes using two different kinds of insertion conditions. METHOD Cochlear implantations with the Advanced Bionics IJ® electrode were performed in an artificial cochlear model with a constant insertional speed of 0.5 mm/s provided by a linear actor. Amplitude pressure changes and number of pressure peaks were evaluated for every part. RESULT Intracochlear fluid pressure changes are assumed to affect the preservation of residual hearing and should be minimized. The stability and reduction of movement of a lateral wall IJ® electrode increase at deeper insertion and affect intracochlear fluid pressure amplitude.
Collapse
|
29
|
Use of a mid-scala and a lateral wall electrode in children: insertion depth and hearing preservation. Acta Otolaryngol 2017; 137:1-7. [PMID: 27472299 DOI: 10.1080/00016489.2016.1208367] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
CONCLUSIONS Atraumatic insertion of the HiFocusTM Mid-Scala (HFMS) electrode via the round window was successfully achieved in seven children. Residual hearing 6 months post-operatively was preserved to within 10 dB HL of the pre-operative audiogram at 500 Hz for six children, indicating minimal initial insertion trauma to the cochlea. OBJECTIVES The objectives were to document the clinical experience and evaluate differences between HFMS and HiFocusTM 1j (HF1j) by means of insertion depth and hearing preservation results. METHOD Nineteen children were prospectively recruited and consecutively implanted with the HF1j electrode (n = 12) or the HFMS electrode (n = 7) via the round window. Average median angular insertion depths and the amount of residual hearing preserved at 6 months post-operatively were compared between the two electrode groups. RESULTS The median angular insertion depth for the HF1j was 439° and for the HFMS 435°. Preservation of residual hearing at 500 Hz was assessed in seven HFMS subjects and 11 HF1j subjects. Based on the Skarzynski formula, three out of seven subjects (42%) in the HFMS group had their residual hearing completely preserved at 500 Hz. In the control group, no subjects had complete hearing preservation and five subjects had a complete loss of residual hearing.
Collapse
|
30
|
Residual Hearing Preservation with the Evo® Cochlear Implant Electrode Array: Preliminary Results. Int Arch Otorhinolaryngol 2016; 20:353-358. [PMID: 27746839 PMCID: PMC5063727 DOI: 10.1055/s-0036-1572530] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 11/15/2015] [Indexed: 10/25/2022] Open
Abstract
Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting soft-surgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 +/- 16.1 dB HL up to 500 Hz and 15.7 +/- 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.
Collapse
|
31
|
The Effect of Residual Acoustic Hearing and Adaptation to Uncertainty on Speech Perception in Cochlear Implant Users: Evidence From Eye-Tracking. Ear Hear 2016; 37:e37-51. [PMID: 26317298 PMCID: PMC4717908 DOI: 10.1097/aud.0000000000000207] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES While outcomes with cochlear implants (CIs) are generally good, performance can be fragile. The authors examined two factors that are crucial for good CI performance. First, while there is a clear benefit for adding residual acoustic hearing to CI stimulation (typically in low frequencies), it is unclear whether this contributes directly to phonetic categorization. Thus, the authors examined perception of voicing (which uses low-frequency acoustic cues) and fricative place of articulation (s/∫, which does not) in CI users with and without residual acoustic hearing. Second, in speech categorization experiments, CI users typically show shallower identification functions. These are typically interpreted as deriving from noisy encoding of the signal. However, psycholinguistic work suggests shallow slopes may also be a useful way to adapt to uncertainty. The authors thus employed an eye-tracking paradigm to examine this in CI users. DESIGN Participants were 30 CI users (with a variety of configurations) and 22 age-matched normal hearing (NH) controls. Participants heard tokens from six b/p and six s/∫ continua (eight steps) spanning real words (e.g., beach/peach, sip/ship). Participants selected the picture corresponding to the word they heard from a screen containing four items (a b-, p-, s- and ∫-initial item). Eye movements to each object were monitored as a measure of how strongly they were considering each interpretation in the moments leading up to their final percept. RESULTS Mouse-click results (analogous to phoneme identification) for voicing showed a shallower slope for CI users than NH listeners, but no differences between CI users with and without residual acoustic hearing. For fricatives, CI users also showed a shallower slope, but unexpectedly, acoustic + electric listeners showed an even shallower slope. Eye movements showed a gradient response to fine-grained acoustic differences for all listeners. Even considering only trials in which a participant clicked "b" (for example), and accounting for variation in the category boundary, participants made more looks to the competitor ("p") as the voice onset time neared the boundary. CI users showed a similar pattern, but looked to the competitor more than NH listeners, and this was not different at different continuum steps. CONCLUSION Residual acoustic hearing did not improve voicing categorization suggesting it may not help identify these phonetic cues. The fact that acoustic + electric users showed poorer performance on fricatives was unexpected as they usually show a benefit in standardized perception measures, and as sibilants contain little energy in the low-frequency (acoustic) range. The authors hypothesize that these listeners may overweight acoustic input, and have problems when this is not available (in fricatives). Thus, the benefit (or cost) of acoustic hearing for phonetic categorization may be complex. Eye movements suggest that in both CI and NH listeners, phoneme categorization is not a process of mapping continuous cues to discrete categories. Rather listeners preserve gradiency as a way to deal with uncertainty. CI listeners appear to adapt to their implant (in part) by amplifying competitor activation to preserve their flexibility in the face of potential misperceptions.
Collapse
|
32
|
Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients: Preliminary Results. Otol Neurotol 2015; 36:1343-8. [PMID: 26176556 PMCID: PMC7187917 DOI: 10.1097/mao.0000000000000829] [Citation(s) in RCA: 86] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate the relationship between intrascalar electrode location, electrode type (lateral wall, perimodiolar, and midscala), and angular insertion depth on residual hearing in cochlear implant (CI) recipients. SETTING Tertiary academic hospital. PATIENTS Adult CI patients with functional preoperative residual hearing with preoperative and postoperative CT scans. INTERVENTION Audiological assessment after CI. MAIN OUTCOME MEASURES Electrode location, angular insertion depth, residual hearing post-CI, and word scores with CI (consonant-nucleus-consonant [CNC]). RESULTS Forty-five implants in 36 patients (9 bilateral) were studied. Thirty-eight electrode arrays (84.4%) were fully inserted in scala tympani (ST), 6 (13.3%) crossed from ST to scala vestibuli (SV), and 1 (2.2%) was completely in SV. Twenty-two of the 38 (57.9%) with full ST insertion maintained residual hearing at 1 month compared with 0 of the 7 (0%) with non-full ST insertion (p = 0.005). Three surgical approaches were used: cochleostomy (C) 6/44, extended round window (ERW) 8/44, and round window (RW) 30/44. C and ERW were small group to compare with RW approaches. However if we combine C + ERW, then RW has higher chance of full ST insertion (p = 0.014). Looking at the full ST group, neither age, sex, nor electrode type demonstrated statistically significant associations with hearing preservation (p = 0.646, p = 0.4, and p = 0.929, respectively). The median angular insertion depth was 429° (range, 373°-512°) with no significant difference between the hearing and nonhearing preserved groups (p = 0.287). CONCLUSION Scalar excursion is a strong predictor of losing residual hearing. However, neither age, sex, electrode type, nor angular insertion depth was correlated with hearing preservation in the full ST group. Techniques to decrease the risk of electrode excursion from ST are likely to result in improved residual hearing and CI performance.
Collapse
|
33
|
Abstract
CONCLUSION The correlations between behavioral and auditory steady-state response (ASSR) thresholds were significant at 500, 1000, 2000, and 4000 Hz. ASSR presented high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates when compared with warble-tone audiometry. OBJECTIVES To assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in dichotic single-frequency ASSR with behavioral thresholds at 500, 1000, 2000, and 4000 Hz. METHODS This was a comparative study between ASSR and warble-tone audiometry thresholds in 40 cochlear implant candidates (80 ears) before cochlear implantation with bilateral severe-to-profound sensorineural hearing loss. RESULTS Thresholds were obtained in 62.5% of all frequencies evaluated in warble-tone audiometry and in 63.1% in the ASSR. ASSR sensitivity was 96% and specificity was 91.6%. Mean differences between behavioral and ASSR thresholds did not reach significance at any frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1000, and 2000 Hz and moderate in 4000 Hz, with correlation coefficients varying from 0.65 to 0.81. On 90% of occasions, ASSR thresholds were acquired within 10 dB of behavioral thresholds.
Collapse
|
34
|
Abstract
CONCLUSION Bilateral electric acoustic stimulation (EAS) effectively improved speech perception in noise and sound localization in patients with high-frequency hearing loss. OBJECTIVE To evaluate bilateral EAS efficacy of sound localization detection and speech perception in noise in two cases of high-frequency hearing loss. METHODS Two female patients, aged 38 and 45 years, respectively, received bilateral EAS sequentially. Pure-tone audiometry was performed preoperatively and postoperatively to evaluate the hearing preservation in the lower frequencies. Speech perception outcomes in quiet and noise and sound localization were assessed with unilateral and bilateral EAS. RESULTS Residual hearing in the lower frequencies was well preserved after insertion of a FLEX(24) electrode (24 mm) using the round window approach. After bilateral EAS, speech perception improved in quiet and even more so in noise. In addition, the sound localization ability of both cases with bilateral EAS improved remarkably.
Collapse
|
35
|
Abstract
For patients having residual hearing in one ear and a cochlear implant (CI) in the opposite ear, interaural place-pitch mismatches might be partly responsible for the large variability in individual benefit. Behavioral pitch-matching between the two ears has been suggested as a way to individualize the fitting of the frequency-to-electrode map but is rather tedious and unreliable. Here, an alternative method using two-formant vowels was developed and tested. The interaural spectral shift was inferred by comparing vowel spaces, measured by presenting the first formant (F1) to the nonimplanted ear and the second (F2) on either side. The method was first evaluated with eight normal-hearing listeners and vocoder simulations, before being tested with 11 CI users. Average vowel distributions across subjects showed a similar pattern when presenting F2 on either side, suggesting acclimatization to the frequency map. However, individual vowel spaces with F2 presented to the implant did not allow a reliable estimation of the interaural mismatch. These results suggest that interaural frequency-place mismatches can be derived from such vowel spaces. However, the method remains limited by difficulties in bimodal fusion of the two formants.
Collapse
|
36
|
Exploring the clinical approach to the bimodal fitting of hearing aids and cochlear implants: results of an international survey. Acta Otolaryngol 2014; 134:1151-7. [PMID: 25315914 DOI: 10.3109/00016489.2014.914244] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
CONCLUSIONS The results show that the fitting of a contralateral hearing aid (HA) in the non-implanted ear of cochlear implant (CI) recipients is now well established as standard clinical practice. However, there is a lack of experience in HA fitting within the CI centres and the use of published bimodal fitting procedures is poor. The HA is often not refitted after CI switch-on and this may contribute to rejection. Including a bimodal fitting prescription and process in the CI fitting software would make applying a balancing procedure easier and may increase its implementation in routine clinical practice. OBJECTIVE This survey was designed to investigate and understand the current approach to bimodal fitting of HAs and CIs across different countries and the recommendations made to recipients. METHODS Clinicians working with HAs and/or CIs were invited to participate in an international multicentre clinical survey, designed to obtain information on the various approaches towards bimodal hearing and CI and HA device fitting. Forty-one questions were presented to clinicians in experienced CI centres across a range of countries and answers were collected via an online survey. RESULTS In all, 65 responses were obtained from 12 different countries. All clinicians said they would advise a CI user to wear a contralateral HA if indicated. However, a significant number (45%) had either never fitted HAs before or had less than 1 year of experience. In general, there were no specific criteria for selecting candidates to fit with an HA. A strategy to balance the HA with the CI was not used as a standard practice for any of the adults and was used in only 12% of the children. Only half the respondents were aware of the bimodal literature. The majority of professionals (18/30) did not refit the HA after CI switch-on. However, if users complained of sound quality or loudness issues or had poor test results, a follow-up session was provided. The main benefit reported by recipients was improvement in overall sound quality.
Collapse
|
37
|
Abstract
Conclusions Our results indicated that electric acoustic stimulation (EAS) is beneficial for Japanese-speaking patients, including those with less residual hearing at lower frequencies. Comparable outcomes for the patients with less residual hearing indicated that current audiological criteria for EAS could be expanded. Successful hearing preservation results, together with the progressive nature of loss of residual hearing in these patients, mean that minimally invasive full insertion of medium/long electrodes in cochlear implantation (CI) surgery is a desirable solution. The minimally invasive concepts that have been obtained through EAS surgery are, in fact, crucial for all CI patients. Objectives This study was conducted to evaluate hearing preservation results and speech discrimination outcomes of hearing preservation surgeries using medium/long electrodes. Methods A total of 32 consecutive minimally invasive hearing preservation CIs (using a round window approach with deep insertion of a flexible electrode) were performed in 30 Japanese patients (two were bilateral cases), including patients with less residual hearing. Hearing preservation rates as well as speech discrimination/perception scores were investigated on a multicenter basis. Results Postoperative evaluation after full insertion of the flexible electrodes (24 mm, 31.5 mm) showed that residual hearing was well preserved in all 32 ears. In all patients, speech discrimination and perception scores were improved postoperatively.
Collapse
|