1
|
Impact of Glycosylation on Protein-Protein Self-Interactions of Monoclonal Antibodies. Mol Pharm 2024; 21:1414-1423. [PMID: 38386020 DOI: 10.1021/acs.molpharmaceut.3c01069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Protein self-interactions measured via second osmotic virial coefficients (B22) and dynamic light scattering interaction parameter values (kD) are often used as metrics for assessing the favorability of protein candidates and different formulations during monoclonal antibody (MAb) product development. Model predictions of B22 or kD typically do not account for glycans, though glycosylation can potentially impact experimental MAb self-interactions. To the best of our knowledge, the impact of MAb glycosylation on the experimentally measured B22 and kD values has not yet been reported. B22 and kD values of two fully deglycosylated MAbs and their native (i.e., fully glycosylated) counterparts were measured by light scattering over a range of pH and ionic strength conditions. Significant differences between B22 and kD of the native and deglycosylated forms were observed at a range of low to high ionic strengths used to modulate the effect of electrostatic contributions. Differences were most pronounced at low ionic strength, indicating that electrostatic interactions are a contributing factor. Though B22 and kD values were statistically equivalent at high ionic strengths where electrostatics were fully screened, we observed protein-dependent qualitative differences, which indicate that steric interactions may also play a role in the observed B22 and kD differences. A domain-level coarse-grained molecular model accounting for charge differences was considered to potentially provide additional insight but was not fully predictive of the behavior across all of the solution conditions investigated. This highlights that both the level of modeling and lack of inclusion of glycans may limit existing models in making quantitatively accurate predictions of self-interactions.
Collapse
|
2
|
Protein-Mineral Composite Particles with Logarithmic Dependence of Anticancer Cytotoxicity on Concentration of Montmorillonite Nanoplates with Adsorbed Cytochrome c. Pharmaceutics 2023; 15:pharmaceutics15020386. [PMID: 36839708 PMCID: PMC9965668 DOI: 10.3390/pharmaceutics15020386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 01/16/2023] [Indexed: 01/26/2023] Open
Abstract
Montmorillonite (MM) colloid nanoplates have high adsorption capacity due to their large size/thickness ratio, which allows them to be used as carriers for drug delivery. Upon adsorption of the mitochondrial protein cytochrome c (cytC) onto MM plates, the composite cytC-MM particles acquire anticancer properties because of the ability of cancer cells to phagocytize submicron particles (in contrast to the normal cells). In this way, exogenous cytC can be introduced into tumor cells, thereby triggering apoptosis-an irreversible cascade of biochemical reactions leading to cell death. In the present study, we investigated the physicochemical properties of cytC-MM particles as a function of the cytC concentration in the suspension, namely, the electrophoretic mobility, the mass increment of MM monoplates upon cytC adsorption, the ratio of the adsorbed to the free cytC in the bulk, the protein density on the MM's surface, the number of cytC globules adsorbed on an MM monoplate, the concentration of cytC-MM composite particles in the suspension, and the dependence of cytotoxicity on the cytC-MM particle concentration. For this purpose, we used microelectrophoresis, static and electric light scattering, and a colon cancer cell culture to test the cytotoxic effects of the cytC-MM suspensions. The results show that the cytotoxicity depends linearly on the logarithm of the particle concentration in the cytC-MM suspension reaching 97%.
Collapse
|
3
|
Synthesis of Magneto-Controllable Polymer Nanocarrier Based on Poly(N-isopropylacrylamide-co-acrylic Acid) for Doxorubicin Immobilization. Polymers (Basel) 2022; 14:polym14245440. [PMID: 36559806 PMCID: PMC9784437 DOI: 10.3390/polym14245440] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/05/2022] [Accepted: 12/08/2022] [Indexed: 12/15/2022] Open
Abstract
In this work, the preparation procedure and properties of anionic magnetic microgels loaded with antitumor drug doxorubicin are described. The functional microgels were produced via the in situ formation of iron nanoparticles in an aqueous dispersion of polymer microgels based on poly(N-isopropylacrylamide-co-acrylic acid) (PNIPAM-PAA). The composition and morphology of the resulting composite microgels were studied by means of X-ray diffraction, Mössbauer spectroscopy, IR spectroscopy, scanning electron microscopy, atomic-force microscopy, laser microelectrophoresis, and static and dynamic light scattering. The forming nanoparticles were found to be β-FeO(OH). In physiological pH and ionic strength, the obtained composite microgels were shown to possess high colloid stability. The average size of the composites was 200 nm, while the zeta-potential was -27.5 mV. An optical tweezers study has demonstrated the possibility of manipulation with microgel using external magnetic fields. Loading of the composite microgel with doxorubicin did not lead to any change in particle size and colloidal stability. Magnetic-driven interaction of the drug-loaded microgel with model cell membranes was demonstrated by fluorescence microscopy. The described magnetic microgels demonstrate the potential for the controlled delivery of biologically active substances.
Collapse
|
4
|
Ultra-/Small Angle X-ray Scattering (USAXS/SAXS) and Static Light Scattering (SLS) Modeling as a Tool to Determine Structural Changes and Effect on Growth in S. epidermidis. ACS APPLIED BIO MATERIALS 2022; 5:3703-3712. [PMID: 35905477 PMCID: PMC9940853 DOI: 10.1021/acsabm.2c00218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Usually, to characterize bacterial cells' susceptibility to antimicrobials, basic microbiology techniques such as serial dilutions or disk assays are used. In this work, we present an approach focused on combining static light scattering (SLS) and ultra-/small angle X-ray scattering (USAXS/SAXS). This approach was used to support microbiology techniques, with the aim of understanding the structural changes caused to bacteria when they are exposed to different stresses like pH, oxidation, and surfactants. Using USAXS/SAXS and SLS data, we developed a detailed multiscale model for a Gram-positive bacterium, S. epidermidis, and we extracted information regarding changes in the overall size and cell thickness induced by different stresses (i.e., pH and hydrogen peroxide). Increasing the concentration of hydrogen peroxide leads to a progressive reduction in cell wall thickness. Moreover, the concomitant use of pH and hydrogen peroxide provides evidence for a synergy in inhibiting the S. epidermidis growth. These promising results will be used as a starting base to further investigate more complex formulations and improve/refine the data modeling of bacteria in the small angle scattering regime.
Collapse
|
5
|
Light Scattering and Turbidimetry Techniques for the Characterization of Nanoparticles and Nanostructured Networks. NANOMATERIALS 2022; 12:nano12132214. [PMID: 35808049 PMCID: PMC9268389 DOI: 10.3390/nano12132214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 06/15/2022] [Accepted: 06/21/2022] [Indexed: 12/10/2022]
Abstract
Light scattering and turbidimetry techniques are classical tools for characterizing the dynamics and structure of single nanoparticles or nanostructured networks. They work by analyzing, as a function of time (Dynamic Light Scattering, DLS) or angles (Static Light Scattering, SLS), the light scattered by a sample, or measuring, as a function of the wavelength, the intensity scattered over the entire solid angle when the sample is illuminated with white light (Multi Wavelength Turbidimetry, MWT). Light scattering methods probe different length scales, in the ranges of ~5−500 nm (DLS), or ~0.1−5 μm (Wide Angle SLS), or ~1−100 μm (Low Angle SLS), and some of them can be operated in a time-resolved mode, with the possibility of characterizing not only stationary, but also aggregating, polymerizing, or self-assembling samples. Thus, the combined use of these techniques represents a powerful approach for studying systems characterized by very different length scales. In this work, we will review some typical applications of these methods, ranging from the field of colloidal fractal aggregation to the polymerization of biologic networks made of randomly entangled nanosized fibers. We will also discuss the opportunity of combining together different scattering techniques, emphasizing the advantages of a global analysis with respect to single-methods data processing.
Collapse
|
6
|
Application of Dynamic and Static Light Scattering for Size and Shape Characterization of Small Extracellular Nanoparticles in Plasma and Ascites of Ovarian Cancer Patients. Int J Mol Sci 2021; 22:ijms222312946. [PMID: 34884751 PMCID: PMC8657631 DOI: 10.3390/ijms222312946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 11/23/2021] [Indexed: 12/14/2022] Open
Abstract
In parallel to medical treatment of ovarian cancer, methods for the early detection of cancer tumors are being sought. In this contribution, the use of non-invasive static (SLS) and dynamic light scattering (DLS) for the characterization of extracellular nanoparticles (ENPs) in body fluids of advanced serous ovarian cancer (OC) and benign gynecological pathology (BP) patients is demonstrated and critically evaluated. Samples of plasma and ascites (OC patients) or plasma, peritoneal fluid, and peritoneal washing (BP patients) were analyzed. The hydrodynamic radius (Rh) and the radius of gyration (Rg) of ENPs were calculated from the angular dependency of LS intensity for two ENP subpopulations. Rh and Rg of the predominant ENP population of OC patients were in the range 20–30 nm (diameter 40–60 nm). In thawed samples, larger particles (Rh mostly above 100 nm) were detected as well. The shape parameter ρ of both particle populations was around 1, which is typical for spherical particles with mass concentrated on the rim, as in vesicles. The Rh and Rg of ENPs in BP patients were larger than in OC patients, with ρ ≈ 1.1–2, implying a more elongated/distorted shape. These results show that SLS and DLS are promising methods for the analysis of morphological features of ENPs and have the potential to discriminate between OC and BP patients. However, further development of the methodology is required.
Collapse
|
7
|
Stability of Foams in Vacuum Drying Processes. Effects of Interactions between Sugars, Proteins, and Surfactants on Foam Stability and Dried Foam Properties. Foods 2021; 10:foods10081876. [PMID: 34441652 PMCID: PMC8392398 DOI: 10.3390/foods10081876] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 08/05/2021] [Accepted: 08/11/2021] [Indexed: 01/16/2023] Open
Abstract
The hypothesis was that saccharides mediate interactions between surface-active components and that this will have an impact on foam decay during the drying process. Static light scattering was performed to determine changes in interactions between the foam stabilizer on a molecular level. Furthermore, pendant drop and oscillating drop measurements were performed to examine the surface tension and surface rheology. Foams were dried in conventional dryers as well as microwave-supported vacuum dryers. Final foam properties were determined. It was shown that the addition of sugars, often added as protective substances for sensitive organic molecules, resulted in lower repulsion between different types of surface-active components, namely polysorbate 80 and β-lactoglobulin (β-lg). Differences in impact of the types of sugars and between different types of surfactant, protein, and small molecules were observed influencing the foam decay behavior. The interfacial properties of polysorbate 80 and β-lg were influenced by the type of the used sugars. The surface elasticity of protein stabilized surfaces was higher compared to that of polysorbate stabilized systems. Protein stabilized systems remained more stable compared to polysorbate systems, which was also affected by the used saccharide. Overall, a correlation between molecular interactions and foam decay behavior was found.
Collapse
|
8
|
Comparison of Huggins Coefficients and Osmotic Second Virial Coefficients of Buffered Solutions of Monoclonal Antibodies. Polymers (Basel) 2021; 13:601. [PMID: 33671342 PMCID: PMC7922252 DOI: 10.3390/polym13040601] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 02/12/2021] [Accepted: 02/14/2021] [Indexed: 01/08/2023] Open
Abstract
The Huggins coefficient kH is a well-known metric for quantifying the increase in solution viscosity arising from intermolecular interactions in relatively dilute macromolecular solutions, and there has been much interest in this solution property in connection with developing improved antibody therapeutics. While numerous kH measurements have been reported for select monoclonal antibodies (mAbs) solutions, there has been limited study of kH in terms of the fundamental molecular interactions that determine this property. In this paper, we compare measurements of the osmotic second virial coefficient B22, a common metric of intermolecular and interparticle interaction strength, to measurements of kH for model antibody solutions. This comparison is motivated by the seminal work of Russel for hard sphere particles having a short-range "sticky" interparticle interaction, and we also compare our data with known results for uncharged flexible polymers having variable excluded volume interactions because proteins are polypeptide chains. Our observations indicate that neither the adhesive hard sphere model, a common colloidal model of globular proteins, nor the familiar uncharged flexible polymer model, an excellent model of intrinsically disordered proteins, describes the dependence of kH of these antibodies on B22. Clearly, an improved understanding of protein and ion solvation by water as well as dipole-dipole and charge-dipole effects is required to understand the significance of kH from the standpoint of fundamental protein-protein interactions. Despite shortcomings in our theoretical understanding of kH for antibody solutions, this quantity provides a useful practical measure of the strength of interprotein interactions at elevated protein concentrations that is of direct significance for the development of antibody formulations that minimize the solution viscosity.
Collapse
|
9
|
Size measurement of silica nanoparticles by Asymmetric Flow Field-Flow Fractionation coupled to Multi-Angle Light Scattering: A comparison exercise between two metrological institutes. J Chromatogr A 2020; 1638:461859. [PMID: 33465582 DOI: 10.1016/j.chroma.2020.461859] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 12/22/2020] [Accepted: 12/27/2020] [Indexed: 11/29/2022]
Abstract
In this work we present a comparison exercise between two metrological institutes for size measurement of silica nanoparticles by Asymmetrical Flow Field-Flow Fractionation (AF4) coupled to static light scattering. The work has been performed in the frame of a French inter-laboratory comparison (ILC) exercise organized by the nanoMetrology Club (CnM). The general aim of this multi-technique comparison was to improve the measurement process for each technique, after establishing a well-defined measurement procedure. The results obtained by two national metrological institutes (NMIs), the LNE (France) and the SMD (Belgium) by AF4-UV-DRI-MALS will be presented and discussed. Three different samples were characterized: the reference material ERM®-FD304, which is a suspension of colloidal silica in aqueous solution and two silica bimodal samples consisting of two populations of SiO2 nanoparticles of unknown size in aqueous solution, with different populations' ratios. The procedure for the preparation of the sample before the analysis, and main separation parameters have been previously defined between the two institutes and will be described. The principals measured parameters were the weight-average (dge_w), number-average (dge_n) and z-average (dge_z) geometric diameter; the average hydrodynamic diameter (dh); and the diameter obtained by external calibration using polystyrene latex standards (dcal). Results between the two NMIs were comparable and coherent with the expected size values of those obtained by other techniques like Scanning Mobility Particle Sizer (SMPS) and Scanning Electron Microscopy (SEM) also involved in this ILC exercise. Where discrepancies are observed, they leave the results compatible within their uncertainties and underpin the challenges in analysing data and reporting results, making AF4 a powerful tool to compare to other measurement techniques.
Collapse
|
10
|
Temperature Dependence of Protein Solution Viscosity and Protein-Protein Interactions: Insights into the Origins of High-Viscosity Protein Solutions. Mol Pharm 2020; 17:4473-4482. [PMID: 33170708 DOI: 10.1021/acs.molpharmaceut.0c00552] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Protein solution viscosity (η) as a function of temperature was measured at a series of protein concentrations under a range of formulation conditions for two monoclonal antibodies (MAbs) and a globular protein (aCgn). Based on theoretical arguments, a strong temperature dependence for protein-protein interactions (PPI) indicates highly anisotropic, short-ranged attractions that could lead to higher solution viscosities. The semi-empirical Ross-Minton model was used to determine the apparent intrinsic viscosity, shape, and "crowding" factors for each protein as a function of temperature and formulation conditions. The apparent intrinsic viscosity was independent of temperature for aCgn, while a slight decrease with increasing temperature was observed for the MAbs. The temperature dependence of solution viscosity was analyzed using the Andrade-Eyring equation to determine the effective activation energy of viscous flow (Ea,η). While Ea,η values were different for each protein, they were independent of formulation conditions for a given protein. PPI were quantified via the osmotic second virial coefficient (B22) and the protein diffusion interaction parameter (kD) as a function of temperature under the same formulation conditions as the viscosity measurements. Net interactions ranged from strongly attractive to repulsive by changing formulation pH and ionic strength for each protein. Overall, larger activation energies for PPI corresponded to larger activation energies for η, and those were predictive of the highest η values at higher protein concentrations.
Collapse
|
11
|
Determination of the Rayleigh Ratio with an Uncertainty Analysis by Static Light-Scattering Measurements of Certified Reference Materials for Molecular Weight. ANAL SCI 2019; 35:1045-1051. [PMID: 31178550 DOI: 10.2116/analsci.19p103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The most important parameter for light-scattering measurements in the Rayleigh scattering region is the Rayleigh ratio, which is necessary to obtain the absolute scattered light intensity from the relative scattered light intensity. The absolute scattered light intensity is directly related to the molar masses of polymers, colloids, biomolecules, and the like. A new Rayleigh ratio was determined by measuring static light scattering from certified reference materials with highly accurate certified values of the molecular weight determined by several other techniques, such as MALDI-TOF mass spectrometry or size-exclusion chromatography. The new Rayleigh ratio can be used for evaluating the uncertainty of the molecular weight of polymers and macromolecules, as measured by light scattering.
Collapse
|
12
|
Viscosity of Plasma as a Key Factor in Assessment of Extracellular Vesicles by Light Scattering. Cells 2019; 8:cells8091046. [PMID: 31500151 PMCID: PMC6769602 DOI: 10.3390/cells8091046] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 08/19/2019] [Accepted: 09/04/2019] [Indexed: 12/31/2022] Open
Abstract
Extracellular vesicles (EVs) isolated from biological samples are a promising material for use in medicine and technology. However, the assessment methods that would yield repeatable concentrations, sizes and compositions of the harvested material are missing. A plausible model for the description of EV isolates has not been developed. Furthermore, the identity and genesis of EVs are still obscure and the relevant parameters have not yet been identified. The purpose of this work is to better understand the mechanisms taking place during harvesting of EVs, in particular the role of viscosity of EV suspension. The EVs were harvested from blood plasma by repeated centrifugation and washing of samples. Their size and shape were assessed by using a combination of static and dynamic light scattering. The average shape parameter of the assessed particles was found to be ρ ~ 1 (0.94–1.1 in exosome standards and 0.7–1.2 in blood plasma and EV isolates), pertaining to spherical shells (spherical vesicles). This study has estimated the value of the viscosity coefficient of the medium in blood plasma to be 1.2 mPa/s. It can be concluded that light scattering could be a plausible method for the assessment of EVs upon considering that EVs are a dynamic material with a transient identity.
Collapse
|
13
|
Recent applications of light scattering measurement in the biological and biopharmaceutical sciences. Anal Biochem 2016; 501:4-22. [PMID: 26896682 PMCID: PMC5804501 DOI: 10.1016/j.ab.2016.02.007] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/04/2016] [Accepted: 02/05/2016] [Indexed: 01/09/2023]
|
14
|
From osmotic second virial coefficient (B22 ) to phase behavior of a monoclonal antibody. Biotechnol Prog 2015; 31:438-51. [PMID: 25683855 DOI: 10.1002/btpr.2065] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 01/31/2015] [Indexed: 12/14/2022]
Abstract
Antibodies are complex macromolecules and their phase behavior as well as interactions within different solvents and precipitants are still not understood. To shed some light into the processes on a molecular dimension, the occurring self-interactions between antibody molecules were analyzed by means of the osmotic second virial coefficient (B22 ). The determined B22 follows qualitatively the phenomenological Hofmeister series describing the aggregation probability of antibodies for the various solvent compositions. However, a direct correlation between crystallization probability and B22 in form of a crystallization slot does not seem to be feasible for antibodies since the phase behavior is strongly dependent on their anisotropy. Kinetic parameters have to be taken into account due to the molecular size and complexity of the molecules. This is confirmed by a comparison of experimental data with a theoretical phase diagram. On the other hand the solubility is thermodynamically driven and therefore the B22 could be used to establish a universal solubility line for the monoclonal antibody mAb04c and different solvent compositions by using thermodynamic models.
Collapse
|
15
|
Influence of macromolecular precipitants on phase behavior of monoclonal antibodies. Biotechnol Prog 2015; 31:145-53. [PMID: 25504581 DOI: 10.1002/btpr.2027] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 11/29/2014] [Indexed: 11/10/2022]
Abstract
For the successful application of protein crystallization as a downstream step, a profound knowledge of protein phase behavior in solutions is needed. Therefore, a systematic screening was conducted to analyze the influence of macromolecular precipitants in the form of polyethylene glycol (PEG). First, the influence of molecular weight and concentration of PEG at different pH-values were investigated and analyzed in three-dimensional (3-D) phase diagrams to find appropriate conditions in terms of a fast kinetic and crystal size for downstream processing. In comparison to the use of salts as precipitant, PEG was more suitable to obtain compact 3-D crystals over a broad range of conditions, whereby the molecular weight of PEG is, besides the pH-value, the most important parameter. Second, osmotic second virial coefficients as parameters for protein interactions are experimentally determined with static light scattering to gain a deep insight view in the phase behavior on a molecular basis. The PEG-protein solutions were analyzed as a pseudo-one-compartment system. As the precipitant is also a macromolecule, the new approach of analyzing cross-interactions between the protein and the macromolecule PEG in form of the osmotic second cross-virial coefficient (B23 ) was applied. Both parameters help to understand the protein phase behavior. However, a predictive description of protein phase behavior for systems consisting of monoclonal antibodies and PEG as precipitant is not possible, as kinetic phenomena and concentration dependencies were not taken into account.
Collapse
|
16
|
Molar mass, entanglement, and associations of the biofilm polysaccharide of Staphylococcus epidermidis. Biomacromolecules 2013; 14:1474-81. [PMID: 23540609 PMCID: PMC3676870 DOI: 10.1021/bm400149a] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Biofilms are microbial communities that are characterized by the presence of a viscoelastic extracellular polymeric substance (EPS). Studies have shown that polysaccharides, along with proteins and DNA, are a major constituent of the EPS and play a dominant role in mediating its microstructure and rheological properties. Here, we investigate the possibility of entanglements and associative complexes in solutions of extracellular polysaccharide intercellular adhesin (PIA) extracted from Staphylococcus epidermidis biofilms. We report that the weight average molar mass and radius of gyration of PIA isolates are 2.01×10(5)±1200 g/mol and 29.2±1.2 nm, respectively. The coil overlap concentration, c*, was thus determined to be (32±4)×10(-4) g/mL. Measurements of the in situ concentration of PIA (cPIA,biofilm) was found to be (10±2)×10(-4) g/mL.Thus, cPIA,biofilm
Collapse
|
17
|
IR spectroscopic analyses of amyloid fibril formation of β2-microglobulin using a simplified procedure for its in vitro generation at neutral pH. Biophys Chem 2013; 179:35-46. [PMID: 23727989 DOI: 10.1016/j.bpc.2013.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2013] [Revised: 04/29/2013] [Accepted: 05/01/2013] [Indexed: 11/16/2022]
Abstract
β2-microglobulin (β2m) is known to be the major component of fibrillar deposits in the joints of patients suffering from dialysis-related amyloidosis. We have developed a simplified procedure to convert monomeric recombinant β2m into amyloid fibrils at physiological pH by a combination of stirring and heating, enabling us to follow conformational changes associated with the assembly by infrared spectroscopy and electron microscopy. Our studies reveal that fibrillogenesis begins with the formation of relatively large aggregates, with secondary structure not significantly altered by the stirring-induced association. In contrast, the conversion of the amorphous aggregates into amyloid fibrils is associated with a profound re-organization at the level of the secondary and tertiary structures, leading to non-native like parallel arrangements of the β-strands in the fully formed amyloid structure of β2m. This study highlights the power of an approach to investigate the formation of β2m fibrils by a combination of biophysical techniques including IR spectroscopy.
Collapse
|
18
|
pH-dependent self-association of zinc-free insulin characterized by concentration-gradient static light scattering. Biophys Chem 2010; 148:28-33. [PMID: 20202737 PMCID: PMC2856799 DOI: 10.1016/j.bpc.2010.02.002] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2010] [Revised: 02/02/2010] [Accepted: 02/02/2010] [Indexed: 11/26/2022]
Abstract
Insulin self-association at pH 1.85, 1.95, 3.0, 7.2, 8.0 and 10 was studied via composition gradient light scattering (CG-SLS). At pH 1.95 in acetic acid, insulin was found to exist as a monomer, and in pH 1.85 HCl as a dimer. At pH values of 3.0-8.0, the dependence of scattering intensity upon total insulin concentration at concentrations of up to 1.5mg/mL may be quantitatively accounted for by a simple isodesmic association equilibrium scheme requiring only a single association constant for addition of monomer to monomer or any oligomer. At pH 10, the association constant for addition of monomer to monomer was found to be smaller than the association constant for addition of monomer to all higher oligomers by a factor of approximately five. The isodesmic association scheme was also found to quantitatively account for the concentration dependence of the weight-average molecular weight derived from previously published sedimentation equilibrium measurements made at pH 7.0, and the best-fit value of the stepwise equilibrium constant obtained therefrom was in excellent agreement with that obtained from analysis of the light scattering data obtained at pH 7.2.
Collapse
|
19
|
Monitoring the erosion of hydrolytically-degradable nanogels via multiangle light scattering coupled to asymmetrical flow field-flow fractionation. Anal Chem 2010; 82:523-30. [PMID: 20000662 PMCID: PMC2810709 DOI: 10.1021/ac901725m] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
We describe the synthesis and characterization of degradable nanogels that display bulk erosion under physiologic conditions (pH = 7.4, 37 degrees C). Erodible poly(N-isopropylmethacrylamide) nanogels were synthesized by copolymerization with N,O-(dimethacryloyl) hydroxylamine, a cross-linker previously used in the preparation of nontoxic and biodegradable bulk hydrogels. To monitor particle degradation, we employed multiangle light scattering and differential refractometry detection following asymmetrical flow field-flow fractionation. This approach allowed the detection of changes in nanogel molar mass and topology as a function of both temperature and pH. Particle erosion was evident from both an increase in nanogel swelling and a decrease in scattering intensity as a function of time. Following these analyses, the samples were recovered for subsequent characterization by direct particle tracking, which yields hydrodynamic size measurements and enables number density determination. Additionally, we confirmed the conservation of nanogel stimuli-responsivity through turbidity measurements. Thus, we have demonstrated the synthesis of degradable nanogels that erode under conditions and on time scales that are relevant for many drug delivery applications. The combined separation and light scattering detection method is demonstrated to be a versatile means to monitor erosion and should also find applicability in the characterization of other degradable particle constructs.
Collapse
|