1
|
Giada F, Gulizia M, Francese M, Croci F, Santangelo L, Santomauro M, Occhetta E, Menozzi C, Raviele A. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy. J Am Coll Cardiol 2007; 49:1951-1956. [PMID: 17498580 DOI: 10.1016/j.jacc.2007.02.036] [Citation(s) in RCA: 102] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2006] [Revised: 01/30/2007] [Accepted: 02/05/2007] [Indexed: 02/07/2023] [Imported: 09/12/2023]
Abstract
OBJECTIVES The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations. BACKGROUND In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis. METHODS We studied 50 patients with infrequent (< or =1 episode/month), sustained (>1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated. RESULTS A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012). CONCLUSIONS In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.
Collapse
|
Multicenter Study |
18 |
102 |
2
|
Vijgen J, Botto G, Camm J, Hoijer CJ, Jung W, Le Heuzey JY, Lubinski A, Norekvål TM, Santomauro M, Schalij M, Schmid JP, Vardas P. Consensus statement of the European Heart Rhythm Association: updated recommendations for driving by patients with implantable cardioverter defibrillators. Europace 2009; 11:1097-1107. [PMID: 19525498 DOI: 10.1093/europace/eup112] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/12/2023] [Imported: 09/12/2023] Open
Abstract
Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document. [table: see text] Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.
Collapse
|
|
16 |
59 |
3
|
Coppola G, Carità P, Corrado E, Borrelli A, Rotolo A, Guglielmo M, Nugara C, Ajello L, Santomauro M, Novo S, the Italian Study Group of Cardiovascular Emergencies of the Italian Society of Cardiology. ST segment elevations: always a marker of acute myocardial infarction? Indian Heart J 2013; 65:412-423. [PMID: 23993002 PMCID: PMC3860734 DOI: 10.1016/j.ihj.2013.06.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2012] [Accepted: 06/19/2013] [Indexed: 10/26/2022] [Imported: 09/12/2023] Open
Abstract
Chest pain is one of the chief presenting complaints among patients attending Emergency department. The diagnosis of acute myocardial infarction may be a challenge. Various tools such as anamnesis, blood sample (with evaluation of markers of myocardial necrosis), ultrasound techniques and coronary computed tomography could be useful. However, the interpretation of electrocardiograms of these patients may be a real concern. The earliest manifestations of myocardial ischemia typically interest T waves and ST segment. Despite the high sensitivity, ST segment deviation has however poor specificity since it may be observed in many other cardiac and non-cardiac conditions. Therefore, when ST-T abnormalities are detected the physicians should take into account many other parameters (such as risk factors, symptoms and anamnesis) and all the other differential diagnoses. The aim of our review is to overview of the main conditions that may mimic a ST segment Elevation Myocardial Infarction (STEMI).
Collapse
|
Review |
12 |
33 |
4
|
Gargiulo P, Marciano C, Savarese G, D'Amore C, Paolillo S, Esposito G, Santomauro M, Marsico F, Ruggiero D, Scala O, Marzano A, Cecere M, Casaretti L, Perrone Filardi P. Endothelial dysfunction in type 2 diabetic patients with normal coronary arteries: a digital reactive hyperemia study. Int J Cardiol 2013; 165:67-71. [PMID: 21851998 DOI: 10.1016/j.ijcard.2011.07.076] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 06/17/2011] [Accepted: 07/25/2011] [Indexed: 11/29/2022] [Imported: 09/12/2023]
Abstract
BACKGROUND To assess endothelial function (EF) in type 2 diabetic patients with angiographically normal coronaries compared to diabetic patients with obstructive coronary artery disease (CAD) and to non-diabetic patients, with and without CAD. METHODS One hundred eighty-three patients undergoing coronary angiography were divided in: group 1 with diabetes mellitus (DM) and CAD (n = 58); group 2 with DM without CAD (n = 58); group 3 with CAD without DM (n = 31) and group 4 without CAD and DM (n = 36). EF was assessed by reactive hyperemia index (RHI) using a fingertip peripheral arterial tonometry and compared to values obtained in 20 healthy volunteers. RESULTS RHI was significantly lower in patients with DM compared to patients without DM (1.69 ± 0.38 vs 1.84 ± 0.44; p = 0.019). RHI was comparable among groups 1, 2 and 3, each value being significantly lower compared to group 4 (2 ± 0.44; p<0.001 vs group 1; p<0.005 vs group 2; p<0.002 vs group 3). At multivariate analysis DM and CAD were significant predictors of endothelial dysfunction (ED) (OR = 2.29; p = 0.012; OR = 2.76; p = 0.001, respectively), whereas diabetic patients (n = 116) CAD and glycated haemoglobin (HbA1c) were independent significant predictors of ED (OR = 3.05; p = 0.009; OR = 1.96; p = 0.004, respectively). Diabetic patients with ED (n = 67) had higher levels of HbA1c than diabetic patients with normal endothelial function (7.35 ± 0.97 vs 6.87 ± 0.90; p = 0.008) and RHI inversely correlated to HbA1c (p = 0.02; r = -0.210). CONCLUSIONS Diabetic patients with and without CAD show significantly impaired peripheral vascular function compared to non-diabetic patients without CAD. ED in diabetic patients without CAD is comparable to that of patients with CAD but without DM. HbA1c is a weak independent predictor of ED.
Collapse
|
|
12 |
29 |
5
|
Fazio S, Biondi B, Lupoli G, Cittadini A, Santomauro M, Tommaselli AP, Lombardi G, Saccá L. Evaluation, by noninvasive methods, of the effects of acute loss of thyroid hormones on the heart. Angiology 1992; 43:287-293. [PMID: 1558314 DOI: 10.1177/000331979204300402] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] [Imported: 09/12/2023]
Abstract
To evaluate the effects of the acute loss of thyroid hormones on the heart the authors studied 11 women with acute hypothyroidism. The cardiac study was performed by means of electrocardiography (ECG), radionuclide ventriculography (RNV) at rest and under effort, and monodimensional echocardiography (MD-echo) and was repeated with ECG and MD-echo after six months of thyroxine suppressive therapy. The ECG showed a significant prolongation of QT interval and flattening and inversion of T wave with normal heart rate. The MD-echo revealed left ventricular function in the normal range and normal left ventricular dimensions. RNV showed the ejection fraction in the lower normal range at rest, which increased to a smaller extent under effort in comparison with a control group. The ECG performed during suppressive therapy with L-thyroxine yielded normal findings with an increase of heart rate and of R wave amplitude, and the MD-echo showed no significant variations of cardiac function due to the increase of heart rate.
Collapse
|
Comparative Study |
33 |
15 |
6
|
Vijgen J, Botto G, Camm J, Hoijer CJ, Jung W, Le Heuzey JY, Lubinski A, Norekvål TM, Santomauro M, Schalij M, Schmid JP, Vardas P. Consensus statement of the European Heart Rhythm Association: updated recommendations for driving by patients with implantable cardioverter defibrillators. Eur J Cardiovasc Nurs 2010; 9:3-14. [PMID: 20170847 DOI: 10.1016/j.ejcnurse.2010.01.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] [Imported: 09/12/2023]
Abstract
Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document, (Table see text). Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.
Collapse
|
Consensus Development Conference |
15 |
15 |
7
|
Lévy S, Santini L, Capucci A, Oto A, Santomauro M, Riganti C, Raviele A, Cappato R. European Cardiac Arrhythmia Society Statement on the cardiovascular events associated with the use or abuse of energy drinks. J Interv Card Electrophysiol 2019; 56:99-115. [PMID: 31482331 DOI: 10.1007/s10840-019-00610-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 08/06/2019] [Indexed: 02/06/2023] [Imported: 09/12/2023]
Abstract
Energy drinks are increasingly used by young people and young athletes in order to improve their performance alone or in association of other substances, particularly alcohol. In recent years, a number of reports of reports have raised attention on the side-effects associated with the use or abuse of energy drinks particularly serious cardiovascular events. The European Cardiac Arrhythmia Society (ECAS) has undertaken a systematic and critical review of reported data on cardiovascular events including life-threatening arrhythmias with or without cardiac arrest and other cardiovascular events, and discussed in this review the possible causal effect of caffeine and other ingredients contained in energy drinks and the reported events. Twenty-two cardiovascular events were reported in association with the use or abuse of energy drinks. The European Cardiac Arrhythmia Society would like to draw attention on the possible cardiovascular complications that may occur with the consumption of these beverages and to emphasize the prevention measures to be taken particularly in the young population. Well-designed prospective studies are needed to clarify the possible role of energy drinks in inducing the cardiovascular events reported.
Collapse
|
Review |
6 |
11 |
8
|
Fazio S, Santomauro M, Cittadini A, Ferraro S, Lucariello A, Maddalena G, Sacca L. Efficacy of ticlopidine in the prevention of thromboembolic events in patients with VVI pacemakers. Pacing Clin Electrophysiol 1991; 14:168-173. [PMID: 1706501 DOI: 10.1111/j.1540-8159.1991.tb05086.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] [Imported: 09/12/2023]
Abstract
This study was designed to evaluate whether long-term treatment with ticlopidine reduces the incidence of thromboembolic episodes in patients with a VVI pacemaker. One hundred eleven patients with a VVI pacemaker were randomly assigned to two groups: group A (52 patients) was treated with ticlopidine at the dose of 250 mg a day; and group B (59 patients) was not treated and served as a control group. The primary analysis of efficacy of ticlopidine was based on the occurrence of thromboembolic episodes and of cardiovascular and cerebrovascular deaths. The mean follow-up period was 66 months. In group A, there was a significant reduction in the incidence of thromboembolic episodes (P less than 0.05) with a smaller incidence of total cardiovascular and cerebrovascular deaths (8 in group A and 18 in group B; P = 0.05) as compared with group B. Twelve percent of patients had moderate side effects with 1 dropout (epistaxis). Our data confirm the high incidence of thromboembolic events in patients with a VVI pacemaker and demonstrate the efficacy of ticlopidine in preventing them.
Collapse
|
Clinical Trial |
34 |
10 |
9
|
Ferraro S, Fazio S, Santomauro M, Cianfrani M, Mossetti G, Turco S, De Simone G, Gravina E, Matera MG, Marmo E. Cardiac function and sympathetic activity in young diabetics. Diabetes Res Clin Pract 1990; 8:91-99. [PMID: 2307095 DOI: 10.1016/0168-8227(90)90018-o] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] [Imported: 09/12/2023]
Abstract
This study was aimed at evaluating cardiac function, both systolic and diastolic, in young type 1 diabetics with a mean duration of the disease of 10.9 +/- 6 years and without evidence of cardiac autonomic neuropathy and micro- or macroangiopathy. Thirteen diabetics, with good metabolic control, and 10 normal matched subjects were studied by echocardiography at rest and by radionuclide ventriculography both at rest and during effort. The level of plasma catecholamines was also determined. The echocardiographic data were comparable in the two groups. Scintigraphic data showed an increased peak ejection and peak filling rate (P less than 0.001) in diabetics while the other indices of cardiac function were comparable. Norepinephrine (P less than 0.01) and epinephrine (P less than 0.001) were higher in diabetics. A hypothesis is formulated that the higher indices of flow velocities in type 1 diabetics are supported by a sympathetic overactivity.
Collapse
|
|
35 |
10 |
10
|
Santomauro M, Ferraro S, Maddalena G, Fazio S, Covino E, Pappone C, Spampinato N, Chiariello M. Pacemaker malfunction due to subcutaneous emphysema--a case report. Angiology 1992; 43:873-876. [PMID: 1476276 DOI: 10.1177/000331979204301012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] [Imported: 09/12/2023]
Abstract
The authors describe a cas of pacemaker malfunction due to a critical increase of impedance resulting from air entrapment in the pacemaker pocket.
Collapse
|
Case Reports |
33 |
8 |
11
|
Santomauro M, Fazio S, Ferraro S, Maddalena G, Papaccioli G, Pappone C, Betocchi S, Chiariello M. Fourier analysis in patients with different pacing modes. Pacing Clin Electrophysiol 1991; 14:1351-1358. [PMID: 1720528 DOI: 10.1111/j.1540-8159.1991.tb02880.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] [Imported: 09/12/2023]
Abstract
The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionuclide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricle and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (sigma), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV sigma: 17 degrees +/- 4 vs 11 degrees +/- 3, less than 0.001; RV sigma: 31 degrees +/- 7 vs 14 degrees +/- 4, P less than 0.001). In the patients with VVI rate responsive pacemakers, the LV sigma changed from 18.5 +/- 3 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.001, while the RV sigma changed from 30 degrees +/- 8 to 14 degrees +/- 4, P less than 0.001. Instead in the patients with DDD pacemakers, the LV sigma changed from 15.5 degrees +/- 2 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.05, while the RV sigma changed from 29.1 degrees +/- 6 to 14 degrees +/- 4, P less than 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
|
34 |
7 |
12
|
Fazio S, Cittadini A, Sabatini D, Santomauro M, Cocozza M, Oliviero U, Chiariello M, Sacca L. Platelet aggregability in patients with a VVI pacemaker. Pacing Clin Electrophysiol 1993; 16:254-256. [PMID: 7680451 DOI: 10.1111/j.1540-8159.1993.tb01572.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] [Imported: 09/12/2023]
Abstract
Several studies have suggested an increased incidence of thromboembolic events in patients with VVI pacemaker (VVI patients); furthermore, other authors have demonstrated that a treatment with anticoagulants or antiplatelet drugs may be effective in reducing thromboembolic events, thus suggesting an increased formation of platelet thrombi in these patients. In this respect, platelet aggregability was investigated in ten VVI patients and ten age- and sex-matched subjects. beta-thromboglobulin (beta-Tg) and platelet factor 4 (PF4) plasma levels were determined as well as platelet aggregation induced by ADP, collagen, epinephrine, and arachidonic acid. Plasma beta-Tg levels were increased in the patient group (86 +/- 24 vs 24 +/- 13 ng/mL; P < 0.001) in presence of normal PF4 values (14 +/- 11 vs 13 +/- 6 ng/mL; NS). Aggregation curves showed abnormal values of maximal amplitude, slope, and lag time. In particular, maximal amplitude was significantly higher in VVI patients as compared with controls (ADP P < 0.01, collagen P < 0.001, adrenaline P < 0.01, arachidonic acid P < 0.05). These findings strongly suggest an increase of platelet activity in VVI patients.
Collapse
|
|
32 |
6 |
13
|
Ferro A, Duilio C, Santomauro M, Cuocolo A. Walk test at increased levels of heart rate in patients with dual-chamber pacemaker and with normal or depressed left ventricular function. Eur Heart J 2003; 24:2123-2132. [PMID: 14643273 DOI: 10.1016/j.ehj.2003.09.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] [Imported: 09/12/2023] Open
Abstract
BACKGROUND This study focuses the role of heart rate on cardiac output (CO) at rest and during walk test in patients with dual-chamber pacemaker and depressed or normal left ventricular (LV) function. METHODS AND RESULTS In nine patients with ejection fraction (EF) <50% (group A) and in seven with EF 50% (group B) haemodynamics were assessed at rest and during three randomized 6-min walk tests at fixed rate of 70, 90, and 110beats.min(-1). All patients had dual-chamber pacemaker implanted for complete heart block. Left ventricular function was monitored by a radionuclide system. In group A, with increasing pacing-rate from 70 to 110beats.min(-1), CO did not change both at rest and during walk, whereas end-systolic volume (ESV) increased (P<0.05) and stroke volume (SV) decreased from 68+/-6 to 47+/-9ml at rest (P<0.0001) and from 112+/-21 to 76+/-17ml during walk (P<0.005). In group B, with increasing pacing-rate, CO rose from 6.4+/-0.7 to 9.1+/-1.6l.min(-1)at rest (P<0.001) and from 10+/-1.5 to 14.1+/-2.2l.min(-1)during walk (P<0.0001), with no change in ESV and SV. CONCLUSIONS Increasing heart rate in presence of ventricular asynchrony induced by dual-chamber pacing has negative effect on cardiac contractility and does not improve CO at rest or during physical activity in patients with depressed LV function as occurs in those with normal function.
Collapse
|
|
22 |
6 |
14
|
Cuocolo A, Santomauro M, Pace L, Celentano L, Nappi A, Nicolai E, Chiariello M, Salvatore M. Comparison between exercise and trans-oesophageal atrial pacing in patients with coronary artery disease: technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion. Eur J Nucl Med Mol Imaging 1992; 19:119-124. [PMID: 1532937 DOI: 10.1007/bf00184127] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] [Imported: 09/12/2023]
Abstract
In this study we compared the results of exercise and trans-oesophageal atrial pacing (TAP) technetium-99m methoxyisobutyl isonitrile (99mTc-SESTAMIBI) cardiac imaging in the evaluation of left ventricular (LV) function and myocardial perfusion in patients with angiographically proven coronary artery disease. Ten patients (8 men and 2 women, mean age 59 +/- 6 years) were submitted to 3 separate injections of 99mTc-SESTAMIBI, one under control conditions, one after exercise and one after TAP. LV ejection fraction, as measured by electrocardiogram (ECG) gated first pass, decreased from 49 +/- 5% under control conditions to 42 +/- 6% during exercise (P less than 0.05 versus control) and to 43 +/- 8% during TAP (P less than 0.05 versus control and insignificant change versus exercise). Segmental myocardial perfusion analysis was performed on a total of 150 myocardial segments. On both exercise and TAP 99mTc-SESTAMIBI studies, 103 segments (69% of the total) were normal, 32 (21%) had reversible, and 15 (10%) irreversible, perfusion defects. Relative regional tracer uptake was not statistically different between exercise and TAP in normal regions (91.1 +/- 9.1% versus 90.7 +/- 8.5%, respectively), in regions with reversible (61.9 +/- 12% versus 62.4 +/- 10.4%, respectively) and irreversible perfusion defects (55.8 +/- 7.8% versus 58.8 +/- 9.5%, respectively). Our results demonstrated that 99mTc-SESTAMIBI TAP cardiac imaging shows similar results to 99mTc-SESTAMIBI exercise myocardial scintigraphy in the assessment of LV function and myocardial perfusion in patients with coronary artery disease.
Collapse
|
Comparative Study |
33 |
6 |
15
|
Raiola A, Tenore GC, Ritieni A, Santomauro M, Maisto M, Ciampaglia R, Novellino E. In vitro Bioaccessibility, Bioavailability, and Plasma Protein Interaction of New Oral Anticoagulants in the Presence of Macronutrients. Curr Pharm Biotechnol 2018; 19:982-989. [PMID: 30417786 DOI: 10.2174/1389201019666181112100612] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 08/24/2018] [Accepted: 11/02/2018] [Indexed: 11/22/2022] [Imported: 09/12/2023]
Abstract
BACKGROUND Over the last years, a new generation of oral anticoagulants (NOACs), including apixaban, rivaroxaban and dabigatran, has been developed for the control of thrombosis and related disorders. The presence of food within the gastrointestinal (GI) tract can potentially affect the oral bioavailability of drugs. OBJECTIVE In the present paper, we evaluated the stability of these drugs in in vitro GI digestion, with and without the main macronutrients such as proteins, lipids, carbohydrates, and fibers, and their ability to enter into the systemic circulation. In addition, we examined the percentage of the drug binding to plasma proteins, such as human serum albumin, high density- and low density lipoproteins. METHODS The NOACs bioaccessibility was evaluated by an in vitro procedure simulating the gastrointestinal enzymatic system, while their bioavailability was studied by cell culture of Caco-2 cells and in vitro study of transepithelial transport. The in vitro transepithelial permeated NOACs were added to plasma protein solutions simulating the average fasting plasma protein concentrations. The NOACs detection was carried out by HPLC-DAD/ESI-MS analysis. RESULTS GI digestion significantly reduces intestinal bioaccessibility and bioavailability of NOACs, especially as regards apixaban and dabigatran. Interestingly, the co-digestion of fibers led to a strong decrease of NOAC intestinal bioaccessibility and bioavailability, while the effects of the other macronutrients, as well as a low fiber standard meal, had no significant influence in this sense. CONCLUSION Dabigatran, rivaroxaban and apixaban may be administered independently of a standard meal, provided that it does not include a high amount of dietary fibers.
Collapse
|
|
7 |
4 |
16
|
Santomauro M, Fazio S, Ferraro S, Maddalena G, Papaccioli G, Pappone C, Saccà L, Chiariello M. Follow-up of a respiratory rate modulated pacemaker. Pacing Clin Electrophysiol 1992; 15:17-21. [PMID: 1370995 DOI: 10.1111/j.1540-8159.1992.tb02896.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] [Imported: 09/12/2023]
Abstract
The efficacy of 27 respiration sensitive rate modulated pacemakers (Biorate RDP-3 Biotec) implanted in the left pectoral area was evaluated every 3 months during a mean follow-up period of 29 months (range 10-50 months). Rate modulation function was unchanged other than for three patients in whom the auxiliary leads became displaced. Two implants lost ventricular sensing in this nonprogrammable model. In all but the three patients, Holter monitoring demonstrated pacing rate variation corresponding to daily activity. Stress test duration increased from 8.2 +/- 1.5 minutes (in fixed rate VVI rate) to 12.83 +/- 2.0 minutes (in the VVIR mode) (P less than 0.05). Right arm movement increased the pacing rate by 5 +/- 3 beats/min (NS), while the left arm movement increase was 30 +/- 5 beats/min (P less than 0.05). Mental, arithmetic, and nifedipine tests did not change the rate modulated pacing rate. The system responded to a change in respiratory rate by an increase in stimulation rate. A satisfactory response in sensitivity and velocity was present only with medium-high workloads. Interference with rate modulation occurred with movement of the arm ipsilateral to the implanted pulse generator.
Collapse
|
|
33 |
4 |
17
|
Santomauro M, Ottaviano L, Borrelli A, Galasso G, Duilio C, Monteforte N, Padeletti L, Montenero AS, Andrew P, Chiariello M. Efficacy of automatic mode switching in DDDR mode pacemakers: the most 2 study. J Interv Card Electrophysiol 2008; 21:13-17. [PMID: 18231849 DOI: 10.1007/s10840-007-9173-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2007] [Accepted: 10/14/2007] [Indexed: 11/24/2022] [Imported: 08/29/2023]
Abstract
BACKGROUND Effective automatic mode switching (AMS) algorithms capable of detecting a range of supraventricular tachyarrhythmias is important given evidence of atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT) post-implantation of pacemakers. OBJECTIVES The aim of the study was to assess the efficacy, defined as ability to detect a specific atrial rate and activate AMS, of five different AMS mechanisms during simulation of AF, AFL, and AT. MATERIALS AND METHODS A total of 48 subjects (35 men, 13 women; mean age: 69 +/- 8 years) implanted with DDDR pacemakers utilizing five different AMS mechanisms (mean atrial rate, rate cut-off, complex 'fallback' algorithm, retriggerable atrial refractory period, and physiological band 'beat-to-beat') were tested using an external electronic device that simulated the occurrence of supraventricular tachyarrhythmias. AF, AFL, and AT were simulated by delivering low voltage pulse trains at 350, 250 and 160 beats/min, respectively. RESULTS Mean efficacy for all AMS mechanisms was 81% [range: 57% to 100%] at 350 beats/min, 81% [range: 57-100%] at 250 beats/min, and 79% [range: 57-100%] at 160 beats/min. The AMS mechanisms that yielded 100% efficacy were the rate cut-off and physiological band 'beat-to-beat.' CONCLUSION Not all AMS algorithms are equally efficacious at detecting atrial arrhythmias and subsequently activating AMS. Our results suggest that the most efficacious AMS algorithms are those that use rate cut-off and physiological band 'beat-to-beat' to detect supraventricular tachyarrhythmias.
Collapse
|
Comparative Study |
17 |
3 |
18
|
Ferraro S, Maddalena G, D'Agosto V, D'Alto M, Fazio S, Santomauro M, Romano M, Chiariello M. Influence of atenolol on the relationship between heart rate and QT interval in patients with exercise-induced myocardial ischemia. Clin Cardiol 1992; 15:911-915. [PMID: 1473307 DOI: 10.1002/clc.4960151211] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] [Imported: 09/12/2023] Open
Abstract
The aim of this study was to analyze the relationship between heart rate and QT interval (HR-QT) during exercise in control subjects (Group A) and in patients with coronary artery disease (CAD) with effort angina and without previous myocardial infarction (MI) (Group B). The diagnosis of CAD was confirmed by coronarographic examination. The correlation HR-QT was significant (p < 0.001) in both groups on effort and at recovery. The analysis of the regression HR-QT was carried out separately, both on effort in upright position and at rest in supine position, to avoid the influence of posture on QT length. During effort, the regression line showed lower slope and intercept values in Group B (p < 0.001) than those for Group A. A similar behavior was also observed at rest. Thus, at the highest heart rate, where ECG signs of ischemia (ST depression > 1 mm) frequently occurred, a longer QT interval was present in Group B. Moreover, in Group B, the QT interval in the presence of ECG signs of ischemia was significantly longer (p < 0.01) than in Group A at comparable heart rates both on effort and at rest, thereby confirming the result obtained by comparing both regression lines. The same effort protocol was repeated in Group B patients after acute administration of atenolol 100 mg per os. After atenolol administration, the analysis of the regression HR-QT in Group B clearly showed a shorter QT interval than that obtained in washout period during the baseline test at the highest heart rates where the ECG frequently showed signs of ischemia.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
|
33 |
2 |
19
|
Santomauro M, Ottaviano L, Borrelli A, De Lucia V, Riganti C, Ferreira D, Chiariello M. Role of semiautomatic defibrillators in a general hospital: "Naples Heart Project". Resuscitation 2004; 61:183-188. [PMID: 15135195 DOI: 10.1016/j.resuscitation.2004.01.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2003] [Revised: 12/22/2003] [Accepted: 01/09/2004] [Indexed: 10/26/2022] [Imported: 08/29/2023]
Abstract
In Italian hospitals, 85% of patients hospitalized in general medical wards who experience cardiac arrest die, while the incidence is much lower in patients in intensive care units. Defibrillation, in Italian hospitals, often occurs very late, either due to a lack of defibrillators, or due to architectural and structural barriers. The object of an in-hospital emergency service is to prevent and treat cardiac arrest without subsequent complications, such as brain damage, renal failure etc. The Naples Heart Project was based on a feasibility study of the in-hospital emergency service to evaluate and analyze problems associated with type of structure, departmental and institutional dislocation, internal practicability (architectural features and preferential ways), staff numbers and distribution, the calling system for emergency, and the equipment available. The Naples Heart Project began in July 2001, since then it has already created 835 BLSD first responders among the hospital staff; 440 were physicians and physicians still in training, 310 were nurses and 85 were administrative staff.
Collapse
|
Comparative Study |
21 |
1 |
20
|
Rosato G, Santomauro M, Stanco G, Petillo F, Sauro R, Chiariello M, Spampinato N, Rotiroti D. Subacute cardiac rupture complicating myocardial infarction. A case report. Angiology 1996; 47:189-196. [PMID: 8595015 DOI: 10.1177/000331979604700211] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] [Imported: 09/12/2023]
Abstract
The authors have focused this study on the emergence of subacute ventricular free wall rupture in a seventy-six-year-old patient admitted to hospital for inferior acute myocardial infarction. After six days he showed clinical signs of bradycardia and hypotension evolving to electromechanical dissociation. Given an adequate pharmacologic therapy, the patient was submitted to echocardiography, which was believed to be consistent with myocardial rupture, showing a moderate to large pericardial effusion. Pericardiocentesis of 150 mL of bloody fluid resulted in a further improvement in his hemodynamics. The patient underwent cardiac surgery with repair of the myocardial rupture through a large diaphragmatic infarction by a Dacron polyester fiber graft and pacemaker placement. In conclusion the authors confirm the relevant role of clinical data such as persistent chest pain and hemodynamic instability and the value of echocardiography in identifying subacute myocardial free wall rupture after an episode of acute myocardial infarction.
Collapse
|
Case Reports |
29 |
1 |
21
|
Gulizia Chairperson MM, Parrini Co-Chairperson I, Colivicchi Co-Chairperson F, Bisceglia I, Caiazza F, Gensini GF, Mureddu GF, Santomauro M, Ageno W, Ambrosetti M, Aspromonte N, Barni S, Bellocci F, Caldarola P, Carletti M, De Luca L, Di Fusco SA, Di Lenarda A, Di Nisio M, Domenicucci S, Enea I, Francese GM, Lestuzzi C, Lucà F, Maurea N, Nassiacos D, Pedretti RFE, Pusineri E, Roscio G, Rossini R, Russo A, Volterrani M, Gabrielli Co-Chairperson D. [HCF-ANMCO/AICPR/GIEC/ITAHFA/SICOA/SICP/SIMG/SIT Cardiological Societies Council Consensus document: Anticoagulant therapy in venous thromboembolism and atrial fibrillation of the patient with cancer. Current knowledge and new evidence]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2020; 21:687-738. [PMID: 33094745 DOI: 10.1714/3413.33967] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] [Imported: 09/12/2023]
Abstract
Venous thromboembolism (VTE), including pulmonary embolism and deep venous thrombosis, either symptomatic or incidental, is a common complication in the history of cancer disease. The risk of VTE is 4-7-fold higher in oncology patients, and it represents the second leading cause of death, after cancer itself. In cancer patients, compared with the general population, VTE therapy is associated with higher rates of recurrent thrombosis and/or major bleeding. The need for treatment of VTE in patients with cancer is a challenge for the clinician because of the multiplicity of types of cancer, the disease stage and the imbricated cancer treatment. Historically, in cancer patients, low molecular weight heparins have been preferred for treatment of VTE. More recently, in large randomized clinical trials, direct oral anticoagulants (DOACs) demonstrated to reduce the risk of VTE. However, in the "real life", uncertainties remain on the use of DOACs, especially for the bleeding risk in patients with gastrointestinal cancers and the potential drug-to-drug interactions with specific anticancer therapies.In cancer patients, atrial fibrillation can arise as a perioperative complication or for the side effect of some chemotherapy agents, as well as a consequence of some associated risk factors, including cancer itself. The current clinical scores for predicting thrombotic events (CHA2DS2-VASc) or for predicting bleeding (HAS-BLED), used to guide antithrombotic therapy in the general population, have not yet been validated in cancer patients. Encouraging data for DOAC prescription in patients with atrial fibrillation and cancer are emerging: recent post-hoc analysis showed safety and efficacy of DOACs for the prevention of embolic events compared to warfarin in cancer patients. Currently, anticoagulant therapy of cancer patients should be individualized with multidisciplinary follow-up and frequent reassessment. This consensus document represents an advanced state of the art on the subject and provides useful notes on clinical practice.
Collapse
|
|
5 |
1 |
22
|
Ferro A, Duilio C, Santomauro M, Salvatore M, Cuocolo A. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function. Eur J Nucl Med Mol Imaging 2005; 32:1075-1080. [PMID: 15891919 DOI: 10.1007/s00259-005-1790-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2004] [Accepted: 02/04/2005] [Indexed: 11/24/2022] [Imported: 09/12/2023]
Abstract
PURPOSE Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. METHODS Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction >or=50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. RESULTS In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). CONCLUSION Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function.
Collapse
|
Randomized Controlled Trial |
20 |
1 |
23
|
Santomauro M, Ottaviano L, Borrelli A, Riganti C, Priori S, Napolitano C, Chiariello M. [Evaluation of BLS-D training in lay people]. ITALIAN HEART JOURNAL. SUPPLEMENT : OFFICIAL JOURNAL OF THE ITALIAN FEDERATION OF CARDIOLOGY 2004; 5:527-533. [PMID: 15490685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/01/2023] [Imported: 08/29/2023]
Abstract
BACKGROUND The possibility of saving persons with sudden cardiac arrest (SCA) lowers of 10% every minute since the beginning of the event. The early defibrillation (within 4 min) of a person with SCA performed by first responders suitably trained increases the survival rate up to 50%. The basic aim is that early defibrillation is performed as soon as possible by the first responder. METHODS Within the Public Access Defibrillation (PAD) "Napoli Cuore" Project, 220 highway patrol agents of the Campania Region district were trained through theoretical and practical courses to acquire suitable psychomotor skills to perform the first aid. The learning evaluation was performed with a written exam and a practical test to assess how much every agent had learned about basic life support-defibrillation (BLS-D) schemes. RESULTS 98.5% of the participants passed the exams and obtained the BLS-D rescuer license, and 15.5% of them obtained the highest score. The analysis of the report cards showed that most of the participants expressed an excellent opinion about this experience. CONCLUSIONS To implement a PAD project it is necessary to awaken all the structures involved in the campaign against SCA. Hence, it is important that all emergency specialists, public institutions and police departments work all together to make everyone feels safe.
Collapse
|
English Abstract |
21 |
|
24
|
Santomauro M, Duilio C, Tecchia LB, Di Mauro P, Iapicca G, Auricchio L, Filardi PP. [Management of electrical storm in implantable cardioverter-defibrillator recipients]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2010; 11:37S-41S. [PMID: 21416825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023] [Imported: 08/29/2023]
Abstract
The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter-defibrillator (ICD), ES is best defined as three appropriate VT detections in 24h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Antiarrhythmic drugs have been shown to be very effective in treating ES in patients without ICD, whereas in ICD recipients, device programming is probably a key issue to prevent ES. Since sympathetic overreactivity is an important trigger, the risk of shock delivery should be minimized. Antitachycardia pacing can successfully terminate a significant percentage of fast VTs. Important parameters such as the number of VT cycles needed for VT detection can be increased from nominal values to allow spontaneous termination, and safety features that deliver a shock after a programmable time window independent of programming of antitachycardia pacing (sustained rate duration) should be prolonged or disabled. In some cases it may be advisable to turn off the ICD tachy mode to avoid multiple ineffective shocks. Substrate mapping and VT ablation may be useful for the treatment and prevention of ES.
Collapse
|
Comparative Study |
15 |
|
25
|
Pappone C, Lamberti F, Santomauro M, Stabile G, De Simone A, Franciosa P, Senatore G, Loricchio ML, Chiariello M. [A methodological approach to the transcatheter radiofrequency ablation of anomalous Kent-type pathways]. CARDIOLOGIA (ROME, ITALY) 1993; 38:651-660. [PMID: 8111758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/22/2023] [Imported: 09/12/2023]
Abstract
Aim of this study is to suggest our methodological approach for transcatheter ablation of Kent bundles by radiofrequency energy as to the potential ablation sites, the need in unipolar or bipolar recording mode, single catheter or multiple catheters mapping of anomalous pathways, the vascular approach for both left sited and right sited anomalous pathways, and finally the duration and power to supply. The recording of Kent potential and/or a Va-QRS interval > or = 0 ms have been considered significant predictors of success (respectively p < 0.001 and p < 0.05). The unipolar recording mode has been considered critical in the choice of ablation site in 47 (29.9%) patients. A 6-catheter approach for both diagnostic electrophysiologic studies and mapping allowed us to easily localize accessory pathways and to record either a probable or possible Kent potential in a high percentage of patients and to reduce the permanence of the ablation catheter in the left ventricle. By transaortic retrograde approach in ablating left sited anomalous pathways, we obtained a high success rate, while right sited accessory pathway were approached from the inferior vena cava. In right sited anomalous pathway we delivered radiofrequency energy for a longer time in order to avoid a relapse soon after the procedure. We performed ablation of 174/178 (97.7%) anomalous pathways in 165/169 (97.6%) patients. We observed a 3.8% relapse during a mean follow up of 13 +/- 9 months.
Collapse
|
English Abstract |
32 |
|