Abstract
OBJECTIVES
To identify the diagnostic accuracy of common imaging modalities, chest X-ray (CXR) and CT, for diagnosis of COVID-19 in the general emergency population in the UK and to find the association between imaging features and outcomes in these patients.
DESIGN
Retrospective analysis of electronic patient records.
SETTING
Tertiary academic health science centre and designated centre for high consequence infectious diseases in London, UK.
PARTICIPANTS
1198 patients who attended the emergency department with paired reverse transcriptase PCR (RT-PCR) swabs for SARS-CoV-2 and CXR between 16 March and 16 April 2020.
MAIN OUTCOME MEASURES
Sensitivity and specificity of CXR and CT for diagnosis of COVID-19 using the British Society of Thoracic Imaging reporting templates. Reference standard was any RT-PCR positive naso-oropharyngeal swab within 30 days of attendance. ORs of CXR in association with vital signs, laboratory values and 30-day outcomes were calculated.
RESULTS
Sensitivity and specificity of CXR for COVID-19 diagnosis were 0.56 (95% CI 0.51 to 0.60) and 0.60 (95% CI 0.54 to 0.65), respectively. For CT scans, these were 0.85 (95% CI 0.79 to 0.90) and 0.50 (95% CI 0.41 to 0.60), respectively. This gave a statistically significant mean increase in sensitivity with CT of 29% (95% CI 19% to 38%, p<0.0001) compared with CXR. Specificity was not significantly different between the two modalities.CXR findings were not statistically significantly or clinically meaningfully associated with vital signs, laboratory parameters or 30-day outcomes.
CONCLUSIONS
CT has substantially improved diagnostic performance over CXR in COVID-19. CT should be strongly considered in the initial assessment for suspected COVID-19. This gives potential for increased sensitivity and considerably faster turnaround time, where capacity allows and balanced against excess radiation exposure risk.
Collapse