1
|
Yang W, Pu X, Xie W, Li L, Ding Z, Jia L. Isopropanol-promoted DNA extraction by polydopamine functionalized magnetic particles based on metal coordination. Talanta 2024; 275:126115. [PMID: 38663068 DOI: 10.1016/j.talanta.2024.126115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 04/08/2024] [Accepted: 04/13/2024] [Indexed: 05/30/2024]
Abstract
High-quality DNA is an important guarantee to start downstream experiments in many biological and medical research areas. Magnetic particle-based DNA extraction methods from blood mainly depend on electrostatic adsorption in a low-pH environment. However, the strong acidic environment can influence the DNA stability. Herein, a polydopamine-functionalized magnetic particle (PDA@Fe3O4)-based protocol was developed for DNA extraction from whole blood samples. In the protocol, Mg2+ and Ca2+ were utilized to bridge the adsorption of DNA by PDA@Fe3O4 via the metal-mediated coordination. Isopropanol was found to efficiently promote DNA adsorption by triggering the change of the conformation of DNA from B-form to more compact A-form. In 50 % isopropanol solution, the DNA adsorption efficiency was nearly 100 % in the presence of 0.5 mM Ca2+ or 1.5 mM Mg2+. The role of metal ions and isopropanol in DNA adsorption was explored. The protocol averts the strong acidic environment and PCR inhibitors, such as high concentrations of salt or polyethylene glycol. It demonstrates superiority in DNA yield (59.13 ± 3.63 ng μL-1) over the commercial kit (27.33 ± 4.98 ng μL-1) and phenol-chloroform methods (37.90 ± 0.47 ng μL-1). In addition, to simplify the operastion, an automated nucleic acid extraction device was designed and fabricated to extract whole genomic DNA from blood. The feasibility of the device was verified by extracting DNA from cattle and pig blood samples. The extracted DNA was successfully applied to discriminate the beef authenticity by a duplex PCR system. The results demonstrate that the DNA extraction protocol and the automated device have great potential in blood samples.
Collapse
|
2
|
Liu L, Cui J, Chen P, Fatima Z, Xing Y, Liu H, Ren X, Li D. Controllable concentric electric field line distribution for simultaneous separation of DNA. J Chromatogr A 2024; 1727:464990. [PMID: 38744188 DOI: 10.1016/j.chroma.2024.464990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 05/06/2024] [Accepted: 05/09/2024] [Indexed: 05/16/2024]
Abstract
An approach for the controllable separation and concentration of nucleic acid using a circular nonuniform electric field was proposed and developed. Using six different lengths of DNA molecules as standard samples, the distribution of the gradient electric field was increased from the outer circular electrode to the inner rod-shaped electrode, contributing to the migration of DNA molecules at a velocity gradient towards the region with the strongest inner electric field. The DNA molecules were arranged in a distribution of concentric circles that aligned with the distribution of concentric equipotential lines. The concentration of DNA multiplied with the alternation of radius. As a result, this platform allowed simultaneous DNA separation, achieving a resolution range of 1.17-3.03 through an extended electrophoresis time, resulting in enhanced concentration factors of 1.08-6.27. Moreover, the manipulation of the relative height of the inner and outer electrodes enabled precise control over the distribution and the deflection degree of electric field lines, leading to accurate control over DNA deflection.
Collapse
|
3
|
Cooper PL, Steele NS, Hymus CM, Rye MS. Interpretation and reporting considerations of low-level DNA profiles following MinElute® purification of PowerPlex® 21 amplified products. Forensic Sci Int 2024; 360:112064. [PMID: 38805773 DOI: 10.1016/j.forsciint.2024.112064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 05/13/2024] [Accepted: 05/15/2024] [Indexed: 05/30/2024]
Abstract
The generation of high-quality DNA profiles from trace amounts of DNA continues to be an issue in forensic casework. Several methods have been proposed over the years to increase recovery rates for low input DNA, including purification of PCR products, an increase in PCR cycle numbers and increasing injection time or voltage during electrophoresis. In this study, the characteristics of DNA profiles generated using QIAGEN MinElute® purification of Promega PowerPlex® 21 amplified products for low DNA input samples, ranging from 80 pg down to 4 pg, were evaluated. MinElute® purification was found to be a simple, effective and time efficient method, which can greatly improve the resolution of amplified PCR products, recovering 100% of donor concordant alleles from as little 16 pg of input template DNA and generating sufficient allelic information for interpretation from as low as 4 pg inputs. However, as is commonly observed with low template DNA samples, the results exhibited extensive disparity in the effects of stochastic variation in amplification, including increased heterozygote peak height imbalance, stutter ratios and instances of allelic drop-in and drop-out, both within and between replicates. As such, it is important that the extent and variability of these stochastic effects are appropriately incorporated in the development of robust profile interpretation guidelines for DNA profiles generated from purified PCR products.
Collapse
|
4
|
Steele NS, Cooper PL, Rye MS. Evaluation of post-PCR purification methods and subsequent optimisation of the MinElute® PCR Purification Kit for low input DNA samples amplified with PowerPlex® 21. Forensic Sci Int 2024; 360:112043. [PMID: 38705055 DOI: 10.1016/j.forsciint.2024.112043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/19/2024] [Accepted: 04/23/2024] [Indexed: 05/07/2024]
Abstract
Weak and partial DNA profiles are commonly encountered within forensic casework due to amplification of low DNA input samples. One option for increasing allelic detection in such samples is the purification of amplified PCR product using commercially available column-based methods. In this study, four commercially available post-PCR purification methods, QIAGEN MinElute®, Independent Forensics Amplicon™ Rx, Millipore Microcon® and Thermo Fisher Scientific ExoSAP-IT™ were evaluated, comparing the quality of PowerPlex® 21 DNA profiles produced to the standard DNA profile generated prior to purification. An increased detection of alleles above the analytical threshold was observed following purification with the MinElute®, Amplicon™ Rx and Microcon® methods, allowing informative DNA profiles to be recovered using as little as 8 pg DNA. However, post-PCR purification using the ExoSAP-IT™ kit was unsuccessful, with no alleles detected above analytical threshold in samples with ≤16 pg DNA. The MinElute® kit was selected for optimisation on the basis of DNA profile quality, including increased detection of alleles and minimal artefacts. The MinElute® method was optimised by evaluating the number of washes and final elution buffer volume, resulting in a further increase in detection of alleles by reducing the elution buffer volume. Overall, this study showed that PowerPlex® 21 DNA profiles from low input DNA can be successfully enhanced by employing the MinElute® post-PCR purification method.
Collapse
|
5
|
Bertram AM, Conlan XA, van Oorschot RAH, Durdle A. Recovery of DNA from acetaminophen exploring physical state and sampling methods. Forensic Sci Int 2024; 360:112046. [PMID: 38718526 DOI: 10.1016/j.forsciint.2024.112046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 04/15/2024] [Accepted: 04/27/2024] [Indexed: 06/11/2024]
Abstract
Research into the recovery of DNA from illicit drug samples has shown it is possible to get forensically useful profiles from such substrates. However, it is not yet known if the different physical states that drugs can be found in influences the quantity and quality of DNA that can be recovered or what is the best sampling method to adopt for powdered samples. This research used acetaminophen in four different states - large crystalline, powder, in solution, or residue - to determine the efficacy of current DNA technology in recovery and analysis of the resulting sample. Five replicates of each were prepared. Human blood was deposited on or mixed with the drug and left for 1 hour. The surface of the drug was sampled by wet/dry swabbing (where appropriate), or the entire sample was deposited in a tube, and the DNA then extracted using DNA-IQ™. The amount of DNA recovered (ng), degradation index, number of PCR cycles (Ct) required for the IPC to reach threshold, number of alleles in the DNA profile and average peak height (APH) were assessed. All samples, irrespective of the physical state they were collected from, returned full DNA profiles that corresponded to the DNA profile of the blood donor, with no degradation or inhibition detected. It was also found the wet/dry swabbing method returned higher levels of DNA than inclusion of the entire sample into the tube for powdered acetaminophen and the appropriate method to use will be dependent on casework circumstances. The findings of this research further develops our understanding of the recovery of DNA from drugs, and supports the need for further investigation to understand under what conditions DNA can be recovered from illicit substances.
Collapse
|
6
|
Czado N, Houston R, Hughes S. Evaluation of metal ions and DNA recovery from the surface of fired and unfired brass ammunition to improve STR profiling. Int J Legal Med 2024; 138:1265-1272. [PMID: 38433135 DOI: 10.1007/s00414-024-03200-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 02/15/2024] [Indexed: 03/05/2024]
Abstract
Interest in recovering DNA from the surface of ammunition evidence for genotyping has increased over the past few years. Numerous studies have examined a variety of methods to maximize DNA recovery from these types of challenging samples, but successful DNA profiling has been inconsistent. Low amounts of DNA and PCR inhibition due to metal ions have been suggested as the leading causes of poor results; however, no study quantitatively examined the presence of metal ions at various stages of the DNA analysis workflow from DNA collection through to amplification. In this study, the effectiveness of six different DNA collection and purification methods commonly used by forensic laboratories to process brass ammunition for DNA evidence was investigated. The amount of copper, zinc, and other metals co-recovered from fired and unfired brass casings during DNA collection (using numerous soaking, swabbing, and direct PCR protocols) was quantified via Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES). This same panel of metals was subsequently quantified after DNA lysis and purification steps. Results demonstrated that low amounts of DNA, DNA damage, and degradation are more detrimental to STR typing results than PCR inhibition, as metal ions were successfully removed by all DNA purification methods tested. Furthermore, the use of metal ion chelators increased the amount of DNA recovered and number of reportable STR alleles. This research informs the forensic community on the most effective way to collect and process trace amounts of biological material from brass ammunition and similar evidence.
Collapse
|
7
|
Zole E, Sathyanarayanan G, Regenberg B, Kutter JP. Microfluidic isolation of extrachromosomal circular DNA through selective digestion of plasmids and linear DNA using immobilized nucleases. LAB ON A CHIP 2024; 24:3101-3111. [PMID: 38752699 DOI: 10.1039/d3lc01028g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
Extrachromosomal circular DNA (eccDNA) refers to small circular DNA molecules that are distinct from chromosomal DNA and play diverse roles in various biological processes. They are also explored as potential biomarkers for disease diagnosis and precision medicine. However, isolating eccDNA from tissues and plasma is challenging due to low abundance and the presence of interfering linear DNA, requiring time-consuming processes and expert handling. Our study addresses this by utilizing a microfluidic chip tailored for eccDNA isolation, leveraging microfluidic principles for enzymatic removal of non-circular DNA. Our approach involves integrating restriction enzymes into the microfluidic chip, enabling selective digestion of mitochondrial and linear DNA fragments while preserving eccDNA integrity. This integration is facilitated by an in situ photo-polymerized emulsion inside microchannels, creating a porous monolithic structure suitable for immobilizing restriction and exonuclease enzymes (restriction enzyme MssI and exonuclease ExoV). Evaluation using control DNA mixtures and plasma samples with artificially introduced eccDNA demonstrated that our microfluidic chips reduce linear DNA by over 99%, performing comparable to conventional off-chip methods but with substantially faster digestion times, allowing for a remarkable 76-fold acceleration in overall sample preparation time. This technological advancement holds great promise for enhancing the isolation and analysis of eccDNA from tissue and plasma and the potential for increasing the speed of other molecular methods with multiple enzymatic steps.
Collapse
|
8
|
Rayo E, Ulrich GF, Zemp N, Greeff M, Schuenemann VJ, Widmer A, Fischer MC. Minimally destructive hDNA extraction method for retrospective genetics of pinned historical Lepidoptera specimens. Sci Rep 2024; 14:12875. [PMID: 38834639 DOI: 10.1038/s41598-024-63587-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 05/30/2024] [Indexed: 06/06/2024] Open
Abstract
The millions of specimens stored in entomological collections provide a unique opportunity to study historical insect diversity. Current technologies allow to sequence entire genomes of historical specimens and estimate past genetic diversity of present-day endangered species, advancing our understanding of anthropogenic impact on genetic diversity and enabling the implementation of conservation strategies. A limiting challenge is the extraction of historical DNA (hDNA) of adequate quality for sequencing platforms. We tested four hDNA extraction protocols on five body parts of pinned false heath fritillary butterflies, Melitaea diamina, aiming to minimise specimen damage, preserve their scientific value to the collections, and maximise DNA quality and yield for whole-genome re-sequencing. We developed a very effective approach that successfully recovers hDNA appropriate for short-read sequencing from a single leg of pinned specimens using silica-based DNA extraction columns and an extraction buffer that includes SDS, Tris, Proteinase K, EDTA, NaCl, PTB, and DTT. We observed substantial variation in the ratio of nuclear to mitochondrial DNA in extractions from different tissues, indicating that optimal tissue choice depends on project aims and anticipated downstream analyses. We found that sufficient DNA for whole genome re-sequencing can reliably be extracted from a single leg, opening the possibility to monitor changes in genetic diversity maintaining the scientific value of specimens while supporting current and future conservation strategies.
Collapse
|
9
|
Javidanbardan A, Messerian KO, Zydney AL. Membrane technology for the purification of RNA and DNA therapeutics. Trends Biotechnol 2024; 42:714-727. [PMID: 38212210 DOI: 10.1016/j.tibtech.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 11/29/2023] [Accepted: 11/30/2023] [Indexed: 01/13/2024]
Abstract
Nucleic acid therapeutics have the potential to revolutionize the biopharmaceutical industry, providing highly effective vaccines and novel treatments for cancers and genetic disorders. The successful commercialization of these therapeutics will require development of manufacturing strategies specifically tailored to the purification of nucleic acids. Membrane technologies already play a critical role in the downstream processing of nucleic acid therapeutics, ranging from clarification to concentration to selective purification. This review provides an overview of how membrane systems are currently used for nucleic acid purification, while highlighting areas of future need and opportunity, including adoption of membranes in continuous bioprocessing.
Collapse
|
10
|
da Fonseca LLCG, Rocha DN, Cintra HA, de Araújo LL, dos Santos GLM, de Faria LL, Salú MDS, Leite SHDS, Rocha AD, Lopes MDCB, Ferreira IR, Gomes LHF, Guida LC. Establishing a Standardized DNA Extraction Method Using NaCl from Oral Mucosa Cells for Its Application in Imprinting Diseases Such as Prader-Willi and Angelman Syndromes: A Preliminary Investigation. Genes (Basel) 2024; 15:641. [PMID: 38790270 PMCID: PMC11120874 DOI: 10.3390/genes15050641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/11/2024] [Accepted: 05/11/2024] [Indexed: 05/26/2024] Open
Abstract
BACKGROUND Diagnosing imprinting defects in neonates and young children presents challenges, often necessitating molecular analysis for a conclusive diagnosis. The isolation of genetic material from oral swabs becomes crucial, especially in settings where blood sample collection is impractical or for vulnerable populations like newborns, who possess limited blood volumes and are often too fragile for invasive procedures. Oral swab samples emerge as an excellent source of DNA, effectively overcoming obstacles associated with rare diseases. METHODS In our study, we specifically addressed the determination of the quality and quantity of DNA extracted from oral swab samples using NaCl procedures. RESULTS We compared these results with extractions performed using a commercial kit. Subsequently, the obtained material underwent MS-HRM analysis for loci associated with imprinting diseases such as Prader-Willi and Angelman syndromes. CONCLUSIONS Our study emphasizes the significance of oral swab samples as a reliable source for obtaining DNA for MS-HRM analysis. NaCl extraction stands out as a practical and cost-effective method for genetic studies, contributing to a molecular diagnosis that proves particularly beneficial for patients facing delays in characterization, ultimately influencing their treatment.
Collapse
|
11
|
Stan E, Muresan CO, Dumache R, Ciocan V, Ungureanu S, Mihailescu A, Daescu E, Duda-Seiman C, Menghiu G, Hutanu D, Enache A. From Jane Doe to Sofia: DNA Extraction Protocol from Bones and Teeth without Liquid Nitrogen for Identifying Skeletal Remains. Int J Mol Sci 2024; 25:5114. [PMID: 38791155 PMCID: PMC11120754 DOI: 10.3390/ijms25105114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/04/2024] [Accepted: 05/06/2024] [Indexed: 05/26/2024] Open
Abstract
DNA analysis plays a crucial role in forensic investigations, helping in criminal cases, missing persons inquiries, and archaeological research. This study focuses on the DNA concentration in different skeletal elements to improve human identification efforts. Ten cases of unidentified skeletal remains brought to the Institute of Forensic Medicine in Timisoara, Romania, underwent DNA analysis between 2019 and 2023. The results showed that teeth are the best source for DNA extraction as they contain the highest concentration of genetic material, at 3.68 ng/µL, compared to the petrous temporal bone (0.936 ng/µL) and femur bone (0.633 ng/µL). These findings highlight the significance of teeth in forensic contexts due to their abundant genetic material. Combining anthropological examination with DNA analysis enhances the understanding and precision of identifying human skeletal remains, thus advancing forensic science. Selecting specific skeletal elements, such as the cochlea or teeth, emerges as crucial for reliable genetic analyses, emphasizing the importance of careful consideration in forensic identification procedures. Our study concludes that automated DNA extraction protocols without liquid nitrogen represent a significant advancement in DNA extraction technology, providing a faster, more efficient, and less labor-intensive method for extracting high-quality DNA from damaged bone and tooth samples.
Collapse
|
12
|
Wang B, Xu YZ, Zhou YC, Ha S, Qin XS, Cai J, Cong B, Chen JH, Deng JQ. DNA Extraction and Comparison between Old and Fresh Necrophilic Fly Samples. J Vis Exp 2024. [PMID: 38767369 DOI: 10.3791/66737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024] Open
Abstract
A total of five samples of Chrysomya megacephala samples - three fresh samples, one sample stored in alcohol for 2 years, and one sample stored in dry sealed storage for 2 years protected from light only - were selected to investigate whether a blood DNA extraction kit could extract DNA from necrophilous flies and to determine whether alcohol could prolong the preservation of necrophilous flies' DNA. First, the blood DNA extraction kit was used to extract DNA from their thorax tissues. Then, the DNA purity and concentration were examined using a microplate reader and a fluorometer. Finally, PCR amplification and electrophoresis of the extracted DNA were done with necrophilic fly-specific primers located in the mitochondrial CO I gene sequence. The results showed that the DNA purity of all samples was greater than 2.0. The DNA concentration was observed to be of the following order: fresh samples > alcohol-preserved old samples > untreated, old samples. All samples had specific electrophoretic bands after PCR amplification. In conclusion, a blood DNA extraction kit can be used to extract DNA from necrophilic flies successfully, and the DNA concentration of fresh fly samples is greater than that of old fly samples. The flies can be stored in alcohol for a long time.
Collapse
|
13
|
Dabrowski P, Rasmus M, Jundzill A, Drewa T, Pokrywczynska M. A comparison of five methods to maximize RNA and DNA isolation yield from adipose tissue. PeerJ 2024; 12:e17071. [PMID: 38711623 PMCID: PMC11073010 DOI: 10.7717/peerj.17071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 02/18/2024] [Indexed: 05/08/2024] Open
Abstract
Adipose tissue in the human body occurs in various forms with different functions. It is an energy store, a complex endocrine organ, and a source of cells used in medicine. Many molecular analyses require the isolation of nucleic acids, which can cause some difficulties connected with the large amount of lipids in adipocytes. Ribonucleic acid isolation is particularly challenging due to its low stability and easy degradation by ribonucleases. The study aimed to compare and evaluate five RNA and DNA isolation methods from adipose tissue. The tested material was subcutaneous porcine adipose tissue subjected to different homogenization methods and RNA or DNA purification. A mortar and liquid nitrogen or ceramic beads were used for homogenization. The organic extraction (TriPure Reagent), spin columns with silica-membrane (RNeasy Mini Kit or High Pure PCR Template Preparation Kit), and the automatic MagNA Pure system were used for the purification. Five combinations were compared for RNA and DNA isolation. Obtained samples were evaluated for quantity and quality. The methods were compared in terms of yield (according to tissue mass), purity (A260/280 and A260/230), and nucleic acid degradation (RNA Integrity Number, RIN; DNA Integrity Number, DIN). The results were analyzed statistically. The average RNA yield was highest in method I, which used homogenization with ceramic beads and organic extraction. Low RNA concentration didn't allow us to measure degradation for all samples in method III (homogenization with ceramic beads and spin-column purification). The highest RNA quality was achieved with method IV using homogenization in liquid nitrogen and spin column purification, which makes it the most effective for RNA isolation from adipose tissue. Required values of DNA yield, purity, and integrity were achieved only with spin column-based methods (III and IV). The most effective method for DNA isolation from adipose tissue is method III, using spin-columns without additional homogenization.
Collapse
|
14
|
Gupta A, Yu J, Challita EJ, Standeven J, Bhamla MS. OpenCell: A low-cost, open-source, 3-in-1 device for DNA extraction. PLoS One 2024; 19:e0298857. [PMID: 38696375 PMCID: PMC11065270 DOI: 10.1371/journal.pone.0298857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 02/01/2024] [Indexed: 05/04/2024] Open
Abstract
High-cost DNA extraction procedures pose significant challenges for budget-constrained laboratories. To address this, we introduce OpenCell, an economical, open-source, 3-in-1 laboratory device that combines the functionalities of a bead homogenizer, a microcentrifuge, and a vortex mixer. OpenCell utilizes modular attachments that magnetically connect to a central rotating brushless motor. This motor couples to an epicyclic gearing mechanism, enabling efficient bead homogenization, vortex mixing, and centrifugation within one compact unit. OpenCell's design incorporates multiple redundant safety features, ensuring both the device's and operator's safety. Additional features such as RPM measurement, programmable timers, battery operation, and optional speed control make OpenCell a reliable and reproducible laboratory instrument. In our study, OpenCell successfully isolated DNA from Spinacia oleracea (spinach), with an average yield of 2.3 μg and an A260/A280 ratio of 1.77, demonstrating its effectiveness for downstream applications such as Polymerase Chain Reaction (PCR) amplification. With its compact size (20 cm x 28 cm x 6.7 cm) and lightweight design (0.8 kg), comparable to the size and weight of a laptop, OpenCell is portable, making it an attractive component of a 'lab-in-a-backpack' for resource-constrained environments in low-and-middle-income countries and synthetic biology in remote field stations. Leveraging the accessibility of 3D printing and off-the-shelf components, OpenCell can be manufactured and assembled at a low unit cost of less than $50, providing an affordable alternative to expensive laboratory equipment costing over $4000. OpenCell aims to overcome the barriers to entry in synthetic biology research and contribute to the growing collection of frugal and open hardware.
Collapse
|
15
|
Díez Pérez T, Tafoya AN, Peabody DS, Lakin MR, Hurwitz I, Carroll NJ, López GP. Isolation of nucleic acids using liquid-liquid phase separation of pH-sensitive elastin-like polypeptides. Sci Rep 2024; 14:10157. [PMID: 38698072 PMCID: PMC11065875 DOI: 10.1038/s41598-024-60648-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 04/25/2024] [Indexed: 05/05/2024] Open
Abstract
Extraction of nucleic acids (NAs) is critical for many methods in molecular biology and bioanalytical chemistry. NA extraction has been extensively studied and optimized for a wide range of applications and its importance to society has significantly increased. The COVID-19 pandemic highlighted the importance of early and efficient NA testing, for which NA extraction is a critical analytical step prior to the detection by methods like polymerase chain reaction. This study explores simple, new approaches to extraction using engineered smart nanomaterials, namely NA-binding, intrinsically disordered proteins (IDPs), that undergo triggered liquid-liquid phase separation (LLPS). Two types of NA-binding IDPs are studied, both based on genetically engineered elastin-like polypeptides (ELPs), model IDPs that exhibit a lower critical solution temperature in water and can be designed to exhibit LLPS at desired temperatures in a variety of biological solutions. We show that ELP fusion proteins with natural NA-binding domains can be used to extract DNA and RNA from physiologically relevant solutions. We further show that LLPS of pH responsive ELPs that incorporate histidine in their sequences can be used for both binding, extraction and release of NAs from biological solutions, and can be used to detect SARS-CoV-2 RNA in samples from COVID-positive patients.
Collapse
|
16
|
Bathrick AS, Norsworthy S, Plaza DT, McCormick MN, Slack D, Ramotowski RS. DNA recovery after sequential processing of latent fingerprints on black polyethylene plastic. J Forensic Sci 2024; 69:993-1001. [PMID: 38402545 DOI: 10.1111/1556-4029.15498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/12/2024] [Accepted: 02/12/2024] [Indexed: 02/26/2024]
Abstract
Latent fingerprints on plastic substrates can be visualized by using sequential treatments to enhance the contrast between the fingerprint residues and underlying substrate; however, the extent to which these processes affect subsequent DNA analysis is mostly unknown. Latent fingerprints deposited on black plastic by one donor were visualized with single-process fingerprint powders (i.e., white powder, bichromatic powder, or bichromatic magnetic powder) or sequential treatments (i.e., laser → reflected ultraviolet imaging system (RUVIS) → CA fuming → RUVIS → Rhodamine 6G, Ardrox, and MBD (RAM) or CA fuming → RAM/laser → bichromatic magnetic powder). Samples were examined after the addition of each treatment. DNA was collected using cotton swabs, extracted, quantified, and amplified. DNA yields, peak heights, number of alleles obtained, and percentage of DNA profiles eligible for CODIS upload were examined. Latent fingerprints processed with the laser and up to three sequential treatments generated DNA profiles with significantly higher peaks heights than those of the untreated samples. Fingerprints processed with the laser and up to two sequential treatments generated DNA profiles with significantly more alleles. All methods beginning with laser enhancement generated more CODIS-eligible profiles. Additional research is needed to determine the extent to which initial laser enhancement impacts the success of downstream DNA profiling results. Although DNA profile development is not guaranteed due to the variable quantities of DNA contained within latent fingerprints, the selection of an appropriate latent fingerprint visualization method could maximize both fingerprint detection and the generation of CODIS-eligible DNA profiles.
Collapse
|
17
|
Everson HR, Neyra K, Scarton DV, Chandrasekhar S, Green CM, Schmidt TL, Medintz IL, Veneziano R, Mathur D. Purification of DNA Nanoparticles Using Photocleavable Biotin Tethers. ACS APPLIED MATERIALS & INTERFACES 2024; 16:22334-22343. [PMID: 38635042 DOI: 10.1021/acsami.3c18955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
The number of applications of self-assembled deoxyribonucleic acid (DNA) origami nanoparticles (DNA NPs) has increased drastically, following the development of a variety of single-stranded template DNA (ssDNA) that can serve as the scaffold strand. In addition to viral genomes, such as M13 bacteriophage and lambda DNAs, enzymatically produced ssDNA from various template sources is rapidly gaining traction and being applied as the scaffold for DNA NP preparation. However, separating fully formed DNA NPs that have custom scaffolds from crude assembly mixes is often a multistep process of first separating the ssDNA scaffold from its enzymatic amplification process and then isolating the assembled DNA NPs from excess precursor strands. Only then is the DNA NP sample ready for downstream characterization and application. In this work, we highlight a single-step purification of custom sequence- or M13-derived scaffold-based DNA NPs using photocleavable biotin tethers. The process only requires an inexpensive ultraviolet (UV) lamp, and DNA NPs with up to 90% yield and high purity are obtained. We show the versatility of the process in separating two multihelix bundle structures and a wireframe polyhedral architecture.
Collapse
|
18
|
Nolan M, Linacre A. Cell counting to monitor swab efficiency. J Forensic Sci 2024; 69:1002-1010. [PMID: 38380584 DOI: 10.1111/1556-4029.15495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/08/2024] [Accepted: 02/12/2024] [Indexed: 02/22/2024]
Abstract
Plastic bags, such as ziplock bags, have been used to transport illicit materials worldwide; however, very few studies have tried to optimize the recovery of DNA from these items. This study reports on the best combination of swabs and moistening solution for the greatest recovery of cellular material from ziplock bags. Five swabs, two different variations of Copan Diagnostics nylon 4N6FLOQSwabs, one Medical Wire rayon DRYSWAB, one IsoHelix rayon swab, and one Livingstone cotton swab, were evaluated with two moistening solutions, Triton X-100 in either distilled water or isopropanol. Fingermarks were deposited on ziplock bags and stained with Diamond™ Nucleic Acid Dye to allow visualization of the cells pre- and post-swabbing to determine the number of cells recovered. Based on cell counting data, swabs moistened with Triton X-100 in distilled water performed better than those moistened with isopropanol. Livingstone cotton swabs had the worst recovery of cellular material, while the other swabs tested had no significant difference in their respective solutions. A comparison of the best three swabs for cellular recovery yielded no differences in the DNA concentration extracted. A linear relationship was observed between the log number of cells recovered by swabbing and the DNA concentration following extraction and quantification. The process of monitoring cell collection using fluorescence microscopy on ziplock bags allowed evaluation of swabbing efficacy. Additionally, this study highlights the ability to evaluate cellular recovery independently of traditional extraction, quantification, or profiling techniques which may unequally affect samples.
Collapse
|
19
|
C Zapico S, Matos S, Conte J. Assessment of the efficiency of DNA isolation and profiling applying a temperature-driven method in human remains. Electrophoresis 2024; 45:805-813. [PMID: 38247192 DOI: 10.1002/elps.202300273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/02/2024] [Accepted: 01/10/2024] [Indexed: 01/23/2024]
Abstract
The identification of human remains is of utmost importance in a variety of scenarios. One of the primary identification methods is DNA. DNA extraction from human remains could be difficult, particularly in situations where the remains have been exposed to environmental conditions and other insults. Several studies tried to improve extraction by applying different approaches. ForensicGEM Universal (MicroGem) is a single-tube approach to DNA extraction and a temperature-driven method that could have some advantages with respect to previous techniques, among them, reducing the risk of contamination, not requiring specialized equipment, or several steps to perform. The aim of this study was to assess, for the first time, the efficiency of DNA extraction and quality of STR profiles applying the MicroGem protocol and modifications of this protocol from tooth samples in comparison with automatic extraction (AE). Our results indicated that AE and MicroGem performed similar, though with variability depending on the MicroGem modifications, increasing the DNA yield and STR profile quality when DNA is concentrated with Microcon. These findings demonstrated the efficiency of this methodology for DNA extraction from human remains while also providing a simple and quick technique suitable to apply in a variety of forensic scenarios.
Collapse
|
20
|
Chau C, Mohanan G, Macaulay I, Actis P, Wälti C. Automated Purification of DNA Origami with SPRI Beads. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2308776. [PMID: 38054620 DOI: 10.1002/smll.202308776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Indexed: 12/07/2023]
Abstract
DNA origami synthesis is a well-established technique with wide-ranging applications. In most cases, the synthesized origami must be purified to remove excess materials such as DNA oligos and other functional molecules. While several purification techniques are routinely used, all have limitations, and cannot be integrated with robotic systems. Here the use of solid-phase reversible immobilization (SPRI) beads as a scalable, high-throughput, and automatable method to purify DNA origami is demonstrated. Not only can this method remove unreacted oligos and biomolecules with yields comparable to existing methods while maintaining the high structural integrity of the origami, but it can also be integrated into an automated workflow to purify simultaneously large numbers and quantities of samples. It is envisioned that the SPRI beads purification method will improve the scalability of DNA nanostructures synthesis both for research and commercial applications.
Collapse
|
21
|
Barcenilla C, Cobo-Díaz JF, De Filippis F, Valentino V, Cabrera Rubio R, O'Neil D, Mahler de Sanchez L, Armanini F, Carlino N, Blanco-Míguez A, Pinto F, Calvete-Torre I, Sabater C, Delgado S, Ruas-Madiedo P, Quijada NM, Dzieciol M, Skírnisdóttir S, Knobloch S, Puente A, López M, Prieto M, Marteinsson VT, Wagner M, Margolles A, Segata N, Cotter PD, Ercolini D, Alvarez-Ordóñez A. Improved sampling and DNA extraction procedures for microbiome analysis in food-processing environments. Nat Protoc 2024; 19:1291-1310. [PMID: 38267717 DOI: 10.1038/s41596-023-00949-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 11/09/2023] [Indexed: 01/26/2024]
Abstract
Deep investigation of the microbiome of food-production and food-processing environments through whole-metagenome sequencing (WMS) can provide detailed information on the taxonomic composition and functional potential of the microbial communities that inhabit them, with huge potential benefits for environmental monitoring programs. However, certain technical challenges jeopardize the application of WMS technologies with this aim, with the most relevant one being the recovery of a sufficient amount of DNA from the frequently low-biomass samples collected from the equipment, tools and surfaces of food-processing plants. Here, we present the first complete workflow, with optimized DNA-purification methodology, to obtain high-quality WMS sequencing results from samples taken from food-production and food-processing environments and reconstruct metagenome assembled genomes (MAGs). The protocol can yield DNA loads >10 ng in >98% of samples and >500 ng in 57.1% of samples and allows the collection of, on average, 12.2 MAGs per sample (with up to 62 MAGs in a single sample) in ~1 week, including both laboratory and computational work. This markedly improves on results previously obtained in studies performing WMS of processing environments and using other protocols not specifically developed to sequence these types of sample, in which <2 MAGs per sample were obtained. The full protocol has been developed and applied in the framework of the European Union project MASTER (Microbiome applications for sustainable food systems through technologies and enterprise) in 114 food-processing facilities from different production sectors.
Collapse
|
22
|
Larsen L. Why citizen scientists are gathering DNA from hundreds of lakes - on the same day. Nature 2024; 626:934-935. [PMID: 38383651 DOI: 10.1038/d41586-024-00520-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
|
23
|
Hackett J, Pepenella S, Marco CF, Bodt L, Grajales LR, Petracca J, Burke J, Mayle A, Nash B, Micklos DA. Simple, Robust Invertebrate DNA Barcoding: Chelex-Based DNA Extraction and Optimized COI Amplification. Methods Mol Biol 2024; 2744:119-127. [PMID: 38683314 DOI: 10.1007/978-1-0716-3581-0_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
Chelex-based DNA extractions are well suited for student DNA barcoding research because they are simple, safe, and inexpensive and can be performed without specialized laboratory equipment, allowing them to be performed in classrooms or at home. Extracted DNA is stable in Chelex solution for at least a week at ambient temperature, allowing collection of DNA samples from remote students. These extractions provide quality DNA for many taxa and are optimal for barcoding invertebrates, especially in combination with novel cytochrome c oxidase I (COI) primer cocktails and PCR cycling conditions.
Collapse
|
24
|
Pepenella S, Hackett J, Fernandez-Marco C, Petracca J, Marizzi C, Nash B, Micklos DA. A Rapid, Equipment-Free DNA Isolation Method for DNA Barcoding. Methods Mol Biol 2024; 2744:517-523. [PMID: 38683339 DOI: 10.1007/978-1-0716-3581-0_31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
This rapid, equipment-free DNA isolation procedure using chromatography paper is a simple method that can be performed in less than 30 min and requires no wet lab experience. With minimal expense, it offers an affordable alternative for anyone wanting to explore biodiversity. It also provides an excellent option for use in classrooms or other activities that are time limited. The method works best for plants or lichens, producing stable DNA on Whatman® chromatography paper at room temperature, which can be eluted as needed.
Collapse
|
25
|
Hyman O, Cass A, Enke R, Storm A, Nash B. Cost-Effective DNA Extraction for DNA Barcoding Diverse Biological Samples. Methods Mol Biol 2024; 2744:129-137. [PMID: 38683315 DOI: 10.1007/978-1-0716-3581-0_7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
DNA barcoding employs standard molecular techniques (e.g., DNA extraction, PCR, and Sanger sequencing) to taxonomically identify biological samples. While DNA barcoding is a useful experimental workflow for in-class active learning exercises, extracting DNA from diverse sample types in a time and cost-effective manner can be challenging in a classroom setting. Here, we provide two time and cost-effective methods that have been used by novice students to successfully extract DNA from a variety of animal, fungal, algal, and plant tissues for DNA barcoding.
Collapse
|