251
|
Drozdovitch V, Kesminiene A, Moissonnier M, Veyalkin I, Ostroumova E. Uncertainties in Radiation Doses for a Case-control Study of Thyroid Cancer among Persons Exposed in Childhood to 131 I from Chernobyl Fallout. HEALTH PHYSICS 2020; 119:222-235. [PMID: 33290004 PMCID: PMC7728628 DOI: 10.1097/hp.0000000000001206] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Uncertainties in thyroid doses due to I intake were evaluated for 2,239 subjects in a case-control study of thyroid cancer following exposure to Chernobyl fallout during childhood and adolescence carried out in contaminated regions of Belarus and Russia. Using new methodological developments that became available recently, a Monte Carlo simulation procedure was applied to calculate 1,000 alternative vectors of thyroid doses due to I intake for the study population of 2,239 subjects accounting for sources of shared and unshared errors. An overall arithmetic mean of the stochastic thyroid doses in the study was estimated to be 0.43 Gy and median dose of 0.16 Gy. The arithmetic mean and median of deterministic doses estimated previously for 1,615 of 2,239 study subjects were 0.48 Gy and 0.20 Gy, respectively. The geometric standard deviation of individual stochastic doses varied from 1.59 to 3.61 with an arithmetic mean of 1.94 and a geometric mean of 1.89 over all subjects of the study. These multiple sets of thyroid doses were used to update radiation-related thyroid cancer risks in the study population exposed to I after the Chernobyl accident.
Collapse
|
252
|
Jeetoo SD, Smith J, Pitcher RD. Radiological Studies in Very Low Birth Weight and Extremely Low Birth Weight Neonates: 'ALARA' Revisited. J Trop Pediatr 2020; 66:403-411. [PMID: 31891406 DOI: 10.1093/tropej/fmz080] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Very low birth weight (VLBW) and extremely low birth weight (ELBW) neonates are particularly susceptible to the adverse effects of ionizing radiation. There are limited data on radiographic practice among this population in resource-limited environments. AIM To estimate cumulative effective dose (ED) from diagnostic imaging in VLBW (1000-1500 g) and ELBW (<1000 g) neonates in a resource-limited setting. METHOD A retrospective analysis of all diagnostic imaging examinations performed on ELBW and VLBW neonates born in a large South African public-sector tertiary-level hospital from January through June 2015. Data were stratified by birth weight and imaging examination. The ED was estimated according to the method of Puch-Kapst. Non-parametric t-tests compared the number of radiographs and ED in VLBW and ELBW neonates, at 5% significance. RESULTS Three hundred and ninety-three neonates with median birth weight 1130 (IQR: 930-1340) g were included; 265 (67%) were VLBW and 128 (33%) ELBW; 48 (12%) died at a median of 7 (IQR: 2-17) days. A median of 2 (IQR: 1-5) radiographs were performed per neonate, with median ED 28.8 (IQR: 14.4-90.8) μSv. The median radiographic exposures for VLBW and ELBW neonates were 1 (IQR: 1-4) and 4 (IQR: 2-9), respectively, (p < 0.0001) with median ED 14.4 (IQR: 14.4-70.4) μSv and 71.2 (IQR: 28.8-169.3) μSv, respectively, (p < 0.0001). Radiographic exposure for VLBW neonates was lower than previously documented for this population. CONCLUSION Neonatal radiographic practice in resource-limited settings has the potential to contribute to the discourse on international best practice.
Collapse
|
253
|
Bebeshko VG, Bruslova KM, Volodina TT, Lyashenko LO, Tsvetkova NM, Trychlib IV, Chernysh TO, Boyarskiy VG, Gonchar LO, Kavardakova NV. FEATURES OF CLINICAL SYMPTOMS AND SIGNS, HEMATOLOGICAL AND BIOCHEMICAL PARAMETERS IN CHILDREN WITH JOINT HYPERMOBILITY IN A LATE PERIOD UPON THE CHORNOBYL NPP ACCIDENT. PROBLEMY RADIAT︠S︡IĬNOÏ MEDYT︠S︡YNY TA RADIOBIOLOHIÏ 2020; 24:322-334. [PMID: 31841477 DOI: 10.33145/2304-8336-2019-24-322-334] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Indexed: 01/13/2023]
Abstract
OBJECTIVE establishing the types and frequency of disembriogenetic stigma in children with joint hypermobility given the clinical and laboratory features, genetic component and endocrine regulation of these disorders in a late period upon the accident. MATERIALS AND METHODS Children (n = 109) inhabiting the radiologically contaminated territories and having the connective tissue dysplasia (CTD) signs were involved in the study. Diseases in family history, ossalgia complaints, fractures in a personal history, bone disembriogenetic stigma, joint hypermobility, type of somatic diseases, blood serum biochemical parameters (namely calcium, alkaline phosphatase, total protein, cholesterol, creatinine, iron, ferritin content), serum cortisol, free thyroxine, pituitary thyroid-stimulating hormone (TSH) levels, free amino acid composition in urine and radiation dose were considered. RESULTS Radiation doses in children having the CTD ranged from (0.37 ± 0.11) mSv to (0.56 ± 0.10) mSv with no difference from that in those without CTD. Joint hypermobility (JHM) correlated with cancer in family history (rs = 0.53) and lower extremity varicose vein disease (rs = 0.40) (p < 0.05). Incidence of ossalgia, easy fatigability, and bone fractures was higher in children with CTD. Anomalies of the dentofacial system were first in line (38.5 %) in these children. Proportion of children with grade II JHM and platypodia was lower (rs = 0.42), but with lower extremity deformations was higher (rs = 0.68) (p < 0.05) vs. in the control group. Iron and ferritin deficiencies both with lymphocytosis were more common in children with CTD than in the comparison group (p < 0.05). The increased content of oxyproline, lysine, proline both with glycine deficiency were detected in children having the CTD, i.e. an imbalance of amino acids from the collagen content was observed featuring a predominance of catabolic processes over anabolic ones. There was a direct correlation between the TSH level and the JHM grade (rs = 0.49), although the values of hormone concentration in these children did not exceed the reference range (maximum values were 3.3 μIU/ml). CONCLUSIONS The revealed abnormalities in amino acid content, ferrokinetics, and thyroid function indices can affect the collagen formation, organic matrix structure of bone tissue and significantly deregulate the hemato- poiesis. The later can underlie the pathways of haematologic malignancy development.
Collapse
|
254
|
The Feasibility of Contrast-to-Noise Ratio on Measurements to Evaluate CT Image Quality in Terms of Low-Contrast Detailed Detectability. Med Sci (Basel) 2020; 8:medsci8030026. [PMID: 32640553 PMCID: PMC7563972 DOI: 10.3390/medsci8030026] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 06/19/2020] [Accepted: 06/29/2020] [Indexed: 11/24/2022] Open
Abstract
Background: To evaluate contrast-to-noise ratio (CNR) measurements in assessing image quality, in the context of the detectability performance of low-contrast detail (LCD), in computed tomography (CT) images, since exposure to elevated ionising-type radiation is considered to present excessive carcinogenic risk, whilst also causing distress in study subjects. Methods: An LCD phantom module (CTP515) was utilised in the study. Three dissimilar contrast items were used to analyse the ramifications of the proportions of an object on the CNR. Three multidetector CT (MDCT) scanners were used, with 16-MDCT, 64-MDCT and 80-MDCT frameworks, respectively. The CT scans were recreated using three dissimilar remaking algorithms—soft, standard and lung. The effects exerted on the CNR by various remodelling algorithms, as well as the contrast of various objects along with the size of the objects, were explored. The Hounsfield units of each chosen object (one unit representing the outer portion of the object) and the background and the standard deviation of the noise parameter were quantified, and algorithms were developed using MATLAB. Results: The CNR information was greatly influenced by changing the image recreation calculations and was very much increased in the soft-tissue recreation images using 16-MDCT and 64-MDCT. The CNR information was also increased more in the optimum recreation images than in the reproduced images from the computational procedure used in the 80-MDCT. The results did not show any remarkable contrasts in the CNR values between the different object sizes. Overall, a higher kVp produced an improved CNR in all the CT scanners. In particular, there were prominent upgrades in the CNR information when the kVp was increased from 80 to 120. Higher mAs levels gave better CNR values overall, especially for greater section thicknesses. Based on the CNR estimations, the 64-MDCT provided the best correlation among the CT scanners. Conclusions: The objective LCD appraisal method, based on CNR measurements, was confirmed as being useful for checking the different impacts of kVp, mAs and section thickness on the nature of the picture. This procedure was similarly viable in assessing the impacts of the different reconstruction calculations and the different differentiation questions on the nature of the image.
Collapse
|
255
|
Elshami W, Abuzaid MM, Tekin HO. Effectiveness of Breast and Eye Shielding During Cervical Spine Radiography: An Experimental Study. Risk Manag Healthc Policy 2020; 13:697-704. [PMID: 32636688 PMCID: PMC7335279 DOI: 10.2147/rmhp.s257185] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 06/10/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose This study assessed the effectiveness of breast and eye shielding and measured the radiation dose to radiosensitive tissues (eyes and breasts) due to scatter radiation during cervical spine X-ray radiography examinations. Methods Using an anthropomorphic phantom, the scattered radiation dose was measured before and after the placement of the lead shield over the eyes and breasts in the anteroposterior (AP) and left lateral projection. A regression formula was utilized to determine the exposure. Mean values and standard deviation of breasts and eyes doses were calculated. The paired two sample t-test was used to compare the recorded dose before and after shielding placement. Results Radiation shielding of eyes and breasts during AP cervical spine X-ray decreased radiation dose to the breasts by 99.9% and to the left and right eye by 91% and 89%, respectively. For the left lateral cervical spine X-ray, the radiation dose decreased by 26% and 31% for the left and right eye, respectively, and by 23% and 99% for the left and right breast, respectively. A significant difference was noted comparing the dose before and after the implementing shielding on the eye and breast. Conclusion According to the results presented, the dose is significantly reduced, especially considering that they are not in the area of interest but are exposed to scatter radiation.
Collapse
|
256
|
De Boer SW, Heinen SGH, Goudeketting SR, De Haan MW, Mees BM, Van Den Heuvel DAF, De Vries JPPM. Novel diagnostic and imaging techniques in endovascular iliac artery procedures. Expert Rev Cardiovasc Ther 2020; 18:395-404. [PMID: 32544005 DOI: 10.1080/14779072.2020.1780916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
INTRODUCTION Endovascular revascularization has become the preferred treatment for most patients with iliac artery obstructions, with a high rate of clinical and technical success. AREAS COVERED This review will describe novel developments in the diagnosis and treatment of iliac artery obstructions including the augmentation of preprocedural imaging with advanced flow models, image fusion techniques, and state-of-the-art device-tracking capabilities. EXPERT OPINION The combination of these developments will change the endovascular field within the next 5 years, allowing targeted iliac treatment without the need for radiographic imaging or iodinated contrast media.
Collapse
|
257
|
Kikuchi N, Yanagawa M, Enchi Y, Nakayama A, Yoshida Y, Miyata T, Hata A, Tsubamoto M, Honda O, Tomiyama N. The effect of the reconstruction algorithm for the pulmonary nodule detection under the metal artifact caused by a pacemaker. Medicine (Baltimore) 2020; 99:e20579. [PMID: 32541487 PMCID: PMC7302625 DOI: 10.1097/md.0000000000020579] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
The aim was to compare the effects of metal artifacts from a pacemaker on pulmonary nodule detection among computed tomography (CT) images reconstructed using filtered back projection (FBP), single-energy metal artifact reduction (SEMAR), and forward-projected model-based iterative reconstruction solution (FIRST).Nine simulated nodules were placed inside a chest phantom with a pacemaker. CT images reconstructed using FBP, SEMAR, and FIRST were acquired at low and standard dose, and were evaluated by 2 independent radiologists.FIRST demonstrated the most significantly improved metal artifact and nodule detection on low dose CT (P < .0032), except at 10 mA and 5-mm thickness. At standard-dose CT, SEMAR showed the most significant metal artifact reduction (P < .00001). In terms of nodule detection, no significant differences were observed between FIRST and SEMAR (P = .161).With a pacemaker present, FIRST showed the best nodule detection ability at low-dose CT and SEMAR is comparable to FIRST at standard dose CT.
Collapse
|
258
|
Li RF, Hou CL, Zhou H, Dai YS, Jin LQ, Xi Q, Zhang JH. Comparison on radiation effective dose and image quality of right coronary artery on prospective ECG-gated method between 320 row CT and 2nd generation (128-slice) dual source CT. J Appl Clin Med Phys 2020; 21:256-262. [PMID: 32510768 PMCID: PMC7484880 DOI: 10.1002/acm2.12911] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 01/09/2020] [Accepted: 04/21/2020] [Indexed: 12/21/2022] Open
Abstract
This retrospective study was to compare the image quality of right coronary artery (RCA) and effective radiation dose on prospective ECG‐gated method between 320 row computed tomography (CT) and 2nd generation (128‐slice) dual source CT. A total of 215 candidates underwent CT coronary angiography using prospective ECG‐gated method, 120 patients enrolled in 320 row CT group, and 95 patients in dual source CT group. We divided RCA image quality scores as 1/2/3/4, which means excellent/good/adequate/not assessable and heart rates were considered, as well as the radiation dose. There is no statistically significant difference of RCA image quality of Score 1/2 between 320 row CT and 2nd generation dual source CT, but lower heart rate (<70/min) improved RCA image quality. Meanwhile, the 2nd generation dual source CT scan have significant lower radiation dose. For patients with high level heart rate variation, both prospective ECG‐gated method of 320 row CT scan (Toshiba) and 2nd generation dual source CT scan (Siemens) basically provided good image quality on RCA. There is an advantage of effective radiation dose reduction in prospective ECG‐gated method using the 2nd generation dual source CT scan. After the iodine contrast agent was injected into elbow vein, the threshold triggering method was used to carry out prospective gated scanning, and the acquired fault image was reconstructed by the standard post‐processing software of each manufacturer. The radiation dose value is obtained through the dose report automatically generated after each scan.
Collapse
|
259
|
Hendrick RE. Radiation Doses and Risks in Breast Screening. JOURNAL OF BREAST IMAGING 2020; 2:188-200. [PMID: 38424982 DOI: 10.1093/jbi/wbaa016] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Indexed: 03/02/2024]
Abstract
This article describes radiation doses and cancer risks of digital breast imaging technologies used for breast cancer detection. These include digital mammography (DM), digital breast tomosynthesis (DBT), and newer technologies such as contrast-enhanced digital or spectral mammography (CEM), whole-breast computed tomography, breast-specific gamma imaging (BSGI), molecular breast imaging (MBI), and positron emission mammography (PEM). This article describes the basis for radiation risk estimates, compares radiation doses and risks, and provides benefit-to-radiation-risk ratios for different breast imaging modalities that use ionizing radiation. Current x-ray-based screening modalities such as DM and DBT have small to negligible risks of causing radiation-induced cancers in women of normal screening age. Possible new screening modalities such as CEM have similar small cancer risks. Potential screening modalities that involve radionuclide injection such as BSGI, MBI, and PEM have significantly higher cancer risks unless efficient detection systems and reduced administered doses are used. Benefit-to-radiation-risk estimates are highly favorable for screening with DM and other modalities having comparable (or higher) cancer detection rates and comparably low radiation doses.
Collapse
|
260
|
Oman Z, Feghaly J, Gu L, Nasir A, Forsberg M. Utility of Radiopaque Bypass Graft Markers During Coronary Angiography Following Coronary Artery Bypass Graft Surgery. THE JOURNAL OF INVASIVE CARDIOLOGY 2020; 32:232-234. [PMID: 32385192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND Radiopaque bypass graft markers allow easy visualization of the location of the graft and can minimize contrast use and radiation exposure during follow-up coronary angiography. METHODS This retrospective study analyzed coronary artery bypass graft patients who underwent subsequent coronary angiography in the John Cochrane Veterans Affairs Medical Center from January 2009 until September 2017. RESULTS Patients who underwent diagnostic coronary angiography with proximal graft markers required less contrast use (P<.02) and less fluoroscopy time (P<.01). The presence or absence of proximal graft markers had no significant difference on the rise of creatinine following coronary angiography (P=.28). CONCLUSION Bypass graft markers reduce contrast and radiation use in follow-up coronary angiography and reduce incidence of contrast-induced acute kidney injury.
Collapse
|
261
|
Du M, Gürsoy D, Jacobsen C. Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging. J Appl Crystallogr 2020; 53:748-759. [PMID: 32684890 PMCID: PMC7312132 DOI: 10.1107/s1600576720005816] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 04/27/2020] [Indexed: 02/03/2023] Open
Abstract
Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.
Collapse
|
262
|
Khattab MH, Sherry AD, Manzoor N, Totten DJ, Luo G, Chambless LB, Rivas A, Haynes DS, Cmelak AJ, Attia A. Progressive Vestibular Schwannoma following Subtotal or Near-Total Resection: Dose-Escalated versus Standard-Dose Salvage Stereotactic Radiosurgery. J Neurol Surg B Skull Base 2020; 82:e9-e14. [PMID: 34306912 DOI: 10.1055/s-0040-1712462] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Accepted: 03/19/2020] [Indexed: 10/24/2022] Open
Abstract
Objective Local failure of incompletely resected vestibular schwannoma (VS) following salvage stereotactic radiosurgery (SRS) using standard doses of 12 to 13 Gy is common. We hypothesized that dose-escalated SRS, corrected for biologically effective dose, would have superior local control of high-grade VS progressing after subtotal or near-total resection compared with standard-dose SRS. Design Retrospective cohort study. Setting Tertiary academic referral center. Participants Adult patients treated with linear accelerator-based SRS for progressive VS following subtotal or near-total resection. Main Outcome Measures Dose-escalated SRS was defined by a biologically effective dose exceeding a single-fraction 13-Gy regimen. Study outcomes were local control and neurologic sequelae of SRS. Binary logistic regression was used to evaluate predictors of study outcomes. Results A total of 18 patients with progressive disease following subtotal (71%) and near-total (39%) resection of Koos grade IV disease (94%) were enrolled. Of the 18 patients, 7 were treated with dose-escalated SRS and 11 with standard-dose SRS. Over a median follow-up of 32 months after SRS, local control was 100% in the dose-escalated cohort and 91% in the standard-dose cohort ( p = 0.95). Neurologic sequelae occurred in 28% of patients, including 60% of dose-escalated cohort and 40% of the standard-dose cohort ( p = 0.12), although permanent neurologic sequelae were low at 6%. Conclusions Dose-escalated SRS has similar local control of recurrent VS following progression after subtotal or near-total resection and does not appear to have higher neurologic sequalae. Larger studies are needed.
Collapse
|
263
|
Xiao L, Czito BG, Pang Q, Hui Z, Jing S, Shan B, Wang J. Do Higher Radiation Doses with Concurrent Chemotherapy in the Definitive Treatment of Esophageal Cancer Improve Outcomes? A Meta-Analysis and Systematic Review. J Cancer 2020; 11:4605-4613. [PMID: 32489478 PMCID: PMC7255355 DOI: 10.7150/jca.44447] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 04/26/2020] [Indexed: 12/24/2022] Open
Abstract
Background: To investigate the effects and safety profile of radiation dose escalation utilizing computerized tomography (CT) based radiotherapy techniques (including 3-Dimensional conformal radiotherapy, intensity-modulated radiotherapy and proton therapy) in the definitive treatment of patients with esophageal carcinoma (EC) with definitive concurrent chemoradiotherapy (dCCRT). Methods: All relevant studies utilizing CT-based radiation planning, comparing high-dose (≥ 60 Gy) versus standard-dose (50.4 Gy) radiation for patients with EC were analyzed for this meta-analysis. Results: Eleven studies including 4946 patients met the inclusion criteria, with 96.5% of patients diagnosed with esophageal squamous cell carcinoma (ESCC). The high-dose group demonstrated a significant improvement in local-regional failure (LRF) (OR 2.199, 95% CI 1.487-3.253; P<0.001), two-year local-regional control (LRC) (OR 0.478, 95% CI 0.309-0.740; P=0.001), two-year overall survival (OS) (HR 0.744, 95% CI 0.657-0.843; P<0.001) and five-year OS (HR 0.683, 95% CI 0.561-0.831; P<0.001) rates relative to the standard-dose group. In addition, there was no difference in grade ≥ 3 radiation-related toxicities and treatment-related deaths between the groups. Conclusion: Under the premise of controlling the rate of toxicities, doses of ≥ 60 Gy in CT-based dCCRT of ESCC patients might improve locoregional control and ultimate survival compared to the standard-dose dCCRT. While our review supports a dose-escalation approach in these patients, multiple ongoing randomized trial initial and final reports are awaited to evaluate the effectiveness of this strategy.
Collapse
|
264
|
Kok JL, Teepen JC, van Leeuwen FE, Tissing WJE, Neggers SJCMM, van der Pal HJ, Loonen JJ, Bresters D, Versluys B, van den Heuvel-Eibrink MM, van Dulmen-den Broeder E, van der Heiden-van der Loo M, Aleman BMP, Daniels LA, Haasbeek CJA, Hoeben B, Janssens GO, Maduro JH, Oldenburger F, van Rij C, Tersteeg RJHA, Hauptmann M, Kremer LCM, Ronckers CM. Risk of benign meningioma after childhood cancer in the DCOG-LATER cohort: contributions of radiation dose, exposed cranial volume, and age. Neuro Oncol 2020; 21:392-403. [PMID: 30099534 DOI: 10.1093/neuonc/noy124] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Pediatric cranial radiotherapy (CrRT) markedly increases risk of meningiomas. We studied meningioma risk factors with emphasis on independent and joint effects of CrRT dose, exposed cranial volume, exposure age, and chemotherapy. METHODS The Dutch Cancer Oncology Group-Long-Term Effects after Childhood Cancer (DCOG-LATER) cohort includes 5-year childhood cancer survivors (CCSs) whose cancers were diagnosed in 1963-2001. Histologically confirmed benign meningiomas were identified from the population-based Dutch Pathology Registry (PALGA; 1990-2015). We calculated cumulative meningioma incidence and used multivariable Cox regression and linear excess relative risk (ERR) modeling. RESULTS Among 5843 CCSs (median follow-up: 23.3 y, range: 5.0-52.2 y), 97 developed a benign meningioma, including 80 after full- and 14 after partial-volume CrRT. Compared with CrRT doses of 1-19 Gy, no CrRT was associated with a low meningioma risk (hazard ratio [HR] = 0.04, 95% CI: 0.01-0.15), while increased risks were observed for CrRT doses of 20-39 Gy (HR = 1.66, 95% CI: 0.83-3.33) and 40+ Gy (HR = 2.81, 95% CI: 1.30-6.08). CCSs whose cancers were diagnosed before age 5 versus 10-17 years showed significantly increased risks (HR = 2.38, 95% CI: 1.39-4.07). In this dose-adjusted model, volume was not significantly associated with increased risk (HR full vs partial = 1.66, 95% CI: 0.86-3.22). Overall, the ERR/Gy was 0.30 (95% CI: 0.03-unknown). Dose effects did not vary significantly according to exposure age or CrRT volume. Cumulative incidence after any CrRT was 12.4% (95% CI: 9.8%-15.2%) 40 years after primary cancer diagnosis. Among chemotherapy agents (including methotrexate and cisplatin), only carboplatin (HR = 3.55, 95% CI: 1.62-7.78) appeared associated with meningioma risk. However, we saw no carboplatin dose-response and all 9 exposed cases had high-dose CrRT. CONCLUSION After CrRT 1 in 8 survivors developed late meningioma by age 40 years, associated with radiation dose and exposure age, relevant for future treatment protocols and awareness among survivors and physicians.
Collapse
|
265
|
Sakai Y, Okamura K, Kitamoto E, Kami YN, Shirasaka T, Mikayama R, Tatsumi M, Kondo M, Kato T, Yoshiura K. Improved scan method for dental imaging using multidetector computed tomography: a phantom study. Dentomaxillofac Radiol 2020; 49:20190462. [PMID: 32302213 DOI: 10.1259/dmfr.20190462] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
OBJECTIVES This study aimed to propose an improved scan method to shorten irradiation time and reduce radiation exposure. METHODS The maxilla of a human head CT phantom and a Catphan phantom were used for qualitative and quantitative assessment, respectively. The phantoms were scanned by a 160-row multidetector CT scanner using volumetric and helical scanning. In volumetric scanning, the tube current varied from 120 to 60 to 30 to 20 mA with a tube voltage of 120 kV. Images were reconstructed with a bone kernel using iterative reconstruction (IR) and filtered back projection. As a reference protocol, helical scanning was performed using our clinical setting with 120 kV. Two dental radiologists independently graded the quality of dental images using a 4-point scale (4, superior to reference; 1, unacceptable). For the quantitative assessment, we assessed the system performance from each scan. RESULTS There was no significant difference between the image quality of volumetric scanning using the 60 mA protocol reconstructed with IR and that of the reference (3.08 and 3.00, p = 0.3388). The system performance values at 1.0 cycles/mm of volumetric scanning and 60 mA protocol reconstructed with IR and reference were 0.0038 and 0.0041, respectively. The effective dose of volumetric scanning using the 60 mA protocol was 51.8 µSv, which is a 64.2% reduction to that of the reference. CONCLUSIONS We proposed an improved scan method resulting in a 64.2% reduction of radiation dose with one-fourth of irradiation time by combining volumetric scanning and IR technique in multidetector CT.
Collapse
|
266
|
Kitera N, Matsubara K, Fujioka C, Yokomachi K, Nishimaru E, Kiguchi M, Morimoto A, Ishifuro M, Awai K. [Organ-based Tube-current Modulation Applied on Different MDCT Scanners: Reduction in the Radiation Dose to the Eye Lens at Head CT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:366-374. [PMID: 32307364 DOI: 10.6009/jjrt.2020_jsrt_76.4.366] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE Organ-based tube current modulation (OB-TCM) techniques, which are provided by three vendors, reduces the radiation dose to the lens of the eyes by decreasing the tube current, when the X-ray tube passes over the anterior surface of critical organs. However, the characteristics of dose modulation of these techniques are different. The purpose of this study was to understand the performance characteristics of OB-TCM technique of each computed tomography (CT) vendor at head CT. METHODS We used three CT scanners (SOMATOM Definition Flash; Siemens Healthcare, Revolution CT; GE Healthcare, and Aquilion ONE Genesis Edition; Canon Medical Systems). We measured the radiation dose to the lens surface as evaluation of radiation dose reduction and measured the image noise as index of image quality. We measured the radiation dose rate in the air for analysis of the characteristics of dose modulation in each OB-TCM. RESULTS When applying OB-TCM, the radiation doses for the lens surface were decreased by 28%, 22%, and 25% for Siemens, GE, and Canon CT scanners, respectively, and the image noise level was increased by 5.6%, 8.5%, and 15.1% for Siemens, GE, and Canon CT scanners, respectively. The characteristics of dose modulation in each OB-TCM were also confirmed by measured the radiation dose rate. CONCLUSION We confirmed that each OB-TCM has different influence on image quality and radiation doses for lens surface, due to the different characteristics of dose modulation for each CT vendor.
Collapse
|
267
|
Dymbe B, Mæland EV, Styve JR, Rusandu A. Individualization of computed tomography protocols for suspected pulmonary embolism: a national investigation of routines. J Int Med Res 2020; 48:300060520918427. [PMID: 32290743 PMCID: PMC7157970 DOI: 10.1177/0300060520918427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Objective Given the extensive use of computed tomography (CT) in radiation-sensitive patients such as pregnant and pediatric patients, and considering the importance of tailoring CT protocols to patient characteristics for both the radiation dose and image quality, this study was performed to investigate the extent to which individualization of CT protocols is practiced across Norway. Methods This cross-sectional study involved collection of CT protocols and administration of a mini-questionnaire to obtain additional information about how CT examinations are individualized. All public hospitals performing CT to detect pulmonary embolism were invited, and 41% participated. Results Tailoring a standard protocol to different patient groups was more common than using dedicated protocols. Most of the available radiation dose-reduction approaches were used. However, implementation of these strategies was not systematic. Children and pregnant patients were examined without using dedicated CT protocols or by using protocol adjustments focusing on radiation dose reduction in 30% and 39% of the hospitals, respectively. Conclusion Practice optimization is needed, especially the development of dedicated CT protocols or guidelines that tailor the existing protocol to pediatric and pregnant patients. Practice might benefit from a more systematic approach to individualization of CT examinations, such as inserting tailoring instructions into CT protocols.
Collapse
|
268
|
Barreto I, Verma N, Quails N, Olguin C, Correa N, Mohammed TL. Patient size matters: Effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT. J Appl Clin Med Phys 2020; 21:87-94. [PMID: 32250062 PMCID: PMC7170290 DOI: 10.1002/acm2.12857] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 02/03/2020] [Accepted: 02/21/2020] [Indexed: 11/25/2022] Open
Abstract
Purpose We compare the effect of tube current modulation (TCM) and fixed tube current (FTC) on size‐specific dose estimates (SSDE) and image quality in lung cancer screening with low‐dose CT (LDCT) for patients of all sizes. Methods Initially, 107 lung screening examinations were performed using FTC, which satisfied the Centers for Medicare & Medicaid Services' volumetric CT dose index (CTDIvol) limit of 3.0 mGy for standard‐sized patients. Following protocol modification, 287 examinations were performed using TCM. Patient size and examination parameters were collected and water‐equivalent diameter (Dw) and SSDE were determined for each patient. Regression models were used to correlate CTDIvol and SSDE with Dw. Objective and subjective image quality were measured in 20 patients who had consecutive annual screenings with both FTC and TCM. Results CTDIvol was 2.3 mGy for all FTC scans and increased exponentially with Dw (range = 0.96–4.50 mGy, R2 = 0.73) for TCM scans. As patient Dw increased, SSDE decreased for FTC examinations (R2 = 1) and increased for TCM examinations (R2 = 0.54). Image quality measurements were superior with FTC for smaller sized patients and with TCM for larger sized patients (R2 > 0.5, P < 0.005). Radiologist graded all images acceptable for diagnostic evaluation of lung cancer screening. Conclusion Although FTC protocol offered a consistently low CTDIvol for all patients, it yielded unnecessarily high SSDE for small patients and increased image noise for large patients. Lung cancer screening with LDCT using TCM produces radiation doses that are appropriately reduced for small patients and increased for large patients with diagnostic image quality for all patients.
Collapse
|
269
|
Jones MWM, Kopittke PM, Casey L, Reinhardt J, Blamey FPC, van der Ent A. Assessing radiation dose limits for X-ray fluorescence microscopy analysis of plant specimens. ANNALS OF BOTANY 2020; 125:599-610. [PMID: 31777920 PMCID: PMC7102987 DOI: 10.1093/aob/mcz195] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Accepted: 11/27/2019] [Indexed: 05/05/2023]
Abstract
BACKGROUND AND AIMS X-ray fluorescence microscopy (XFM) is a powerful technique to elucidate the distribution of elements within plants. However, accumulated radiation exposure during analysis can lead to structural damage and experimental artefacts including elemental redistribution. To date, acceptable dose limits have not been systematically established for hydrated plant specimens. METHODS Here we systematically explore acceptable dose rate limits for investigating fresh sunflower (Helianthus annuus) leaf and root samples and investigate the time-dose damage in leaves attached to live plants. KEY RESULTS We find that dose limits in fresh roots and leaves are comparatively low (4.1 kGy), based on localized disintegration of structures and element-specific redistribution. In contrast, frozen-hydrated samples did not incur any apparent damage even at doses as high as 587 kGy. Furthermore, we find that for living plants subjected to XFM measurement in vivo and grown for a further 9 d before being reimaged with XFM, the leaves display elemental redistribution at doses as low as 0.9 kGy and they continue to develop bleaching and necrosis in the days after exposure. CONCLUSIONS The suggested radiation dose limits for studies using XFM to examine plants are important for the increasing number of plant scientists undertaking multidimensional measurements such as tomography and repeated imaging using XFM.
Collapse
|
270
|
Solberg LI, Wang Y, Whitebird R, Lopez-Solano N, Smith-Bindman R. Organizational Factors and Quality Improvement Strategies Associated With Lower Radiation Dose From CT Examinations. J Am Coll Radiol 2020; 17:951-959. [PMID: 32192955 DOI: 10.1016/j.jacr.2020.01.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 01/08/2020] [Accepted: 01/08/2020] [Indexed: 02/03/2023]
Abstract
PURPOSE The aim of this study was to identify organizational factors and quality improvement strategies associated with lower radiation doses from abdominal CT. METHODS Cross-sectional survey was administered to radiology leaders, along with simultaneous measurement of CT radiation dose among 19 health care organizations with 100 imaging centers throughout the United States, Europe, and Japan, using a common dose management software system. After adjusting for patient age, gender, and size, quality improvement strategies were tested for association with mean abdominal CT radiation dose and the odds of a high-dose examination. RESULTS Completed surveys were received from 90 imaging centers (90%), and 182,415 abdominal CT scans were collected during the study period. Radiation doses varied considerably across organizations and centers. Univariate analyses identified eight strategies and systems that were significantly associated with lower average doses or lower frequency of high doses for abdominal CT examinations: tracking patient safety measures, assessing the impact of CT changes, identifying areas for improvement, setting specific goals, organizing improvement teams, tailoring decisions to sites, testing process changes before full implementation, and standardizing workflow. These processes were associated with an 18% to 37% reduction in high-dose examinations (P < .001-.03). In multivariate analysis, having a tracking system for patient safety measures, supportive radiology leaders, and obtaining clear images were associated with a 47% reduction in high-dose examinations. CONCLUSIONS This documentation of the relation between quality improvement strategies and radiation exposure from CT examinations has identified important information for others interested in reducing the radiation exposure of their patients.
Collapse
|
271
|
Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake. Curr Med Sci 2020; 40:178-183. [PMID: 32166681 DOI: 10.1007/s11596-020-2162-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Revised: 12/15/2019] [Indexed: 10/24/2022]
Abstract
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography, radiation dose and iodine intake was evaluated. A total of 121 patients with body mass index (BMI) <26 kg/m2 and heart rate (HR) <70 beats/min were randomly divided into four groups: group A (n=31, 80 kVp, 270 mgI/mL); group B (n=33, 100 kVp, 270 mgI/mL); group C (n=30, 100 kVp, 320 mgI/mL); group D (n=27, 100 kVp, 400 mgI/mL). The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group. The CT values and SD values of the aortic root (AR), subcutaneous fat, left coronary artery opening (LCA), and right coronary artery opening (RCA) were measured in all groups, the signal-to-noise ratio (SNR) and contrast noise ratio (CNR) were calculated, and effective radiation dose and iodine intake were recorded. The subjective assessment for image quality was performed by two physicians using a 4-point scale. The results were compared using the one-way ANOVA and rank sum tests. The image quality of the four groups met the clinical diagnostic requirements. The CT values of AR in groups A, B, C, and D were 537.6±71.4, 447.2±81.9, 445.2±64.9 and 518.5±94.9 Hu, respectively, with no significant difference between group A and group D, or between group B and group C, while CT values in groups B and C were significantly lower than those in groups A and D (P<0.05). In groups A, B, C, and D, the LCA SNR values were 22.7±9.1, 23.3±9.1, 23.3±7.7 and 26.6±8.9, and the RCA CNR values were 26.9±9.8, 28.5±11.4, 27.7±8.8 and 32.1±10.6, respectively. The AR visual scores in groups A, B, C and D were 3.8±0.2, 3.9±0.3, 3.9±0.3 and 4.0±0.3, respectively. There were no significant differences in SNR, CNR and visual score among the four groups (P>0.05). The radiation doses in groups A, B, C and D were 2.6±1.4, 3.6±1.8, 4.9±3.5 and 4.9±2.8 mSv, respectively. The radiation dose in group A was significantly less than that in the rest three groups (P<0.05). The iodine intakes in groups A, B, C and D were 14.9±1.5, 15.0±1.5, 17.7±2.0 and 18.1±2.5 g, respectively. There was no significant difference in the intake of iodine between groups C and D, or between groups A and B, while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D (P<0.05). It was concluded that for patients with low BMI and controlled HR, compared to 100 kVp tube voltage combined with multiple concentration contrast agents, 80 kVp combined with 270 mgI/mL contrast agent is enough to ensure the quality of the images, and can reduce the radiation dose significantly, while reducing the amount of iodine intake notably, thus reducing the incidence of adverse reaction.
Collapse
|
272
|
Wu D, Wang G, Bian B, Liu Z, Li D. Benefits of Low-Dose CT Scan of Head for Patients With Intracranial Hemorrhage. Dose Response 2020; 19:1559325820909778. [PMID: 32214915 PMCID: PMC7065437 DOI: 10.1177/1559325820909778] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 10/23/2019] [Accepted: 01/16/2020] [Indexed: 11/16/2022] Open
Abstract
Objectives: For patients with intracranial hemorrhage (ICH), routine follow-up computed tomography (CT) scans are typically required to monitor the progression of intracranial pathology. Remarkable levels of radiation exposure are accumulated during repeated CT scan. However, the effects and associated risks have still remained elusive. This study presented an effective approach to quantify organ-specific radiation dose of repeated CT scans of head for patients with ICH. We also indicated whether a low-dose CT scan may reduce radiation exposure and keep the image quality highly acceptable for diagnosis. Methods: Herein, 72 patients with a history of ICH were recruited. The patients were divided into 4 groups and underwent CT scan of head with different tube current–time products (250, 200, 150, and 100 mAs). Two experienced radiologists visually rated scores of quality of images according to objective image noise, sharpness, diagnostic acceptability, and artifacts due to physiological noise on the same workstation. Organ-/tissue-specific radiation doses were analyzed using Radimetrics. Results: In conventional CT scan group, signal to noise ratio (SNR) and contrast to noise ratio (CNR) of ICH images were significantly higher than those in normal brain structures. Reducing the tube current–time product may decrease the image quality. However, the predilection sites for ICH could be clearly identified. The SNR and CNR in the predilection sites for ICH were notably higher than other areas. The brain, eye lenses, and salivary glands received the highest radiation dose. Reducing tube current–time product from 250 to 100 mA can significantly reduce the radiation dose. Discussion: We demonstrated that low-dose CT scan of head can still provide reasonable images for diagnosing ICH. The radiation dose can be reduced to ∼45% of the conventional CT scan group.
Collapse
|
273
|
Clauser P, Baltzer PAT, Kapetas P, Hoernig M, Weber M, Leone F, Bernathova M, Helbich TH. Low-Dose, Contrast-Enhanced Mammography Compared to Contrast-Enhanced Breast MRI: A Feasibility Study. J Magn Reson Imaging 2020; 52:589-595. [PMID: 32061002 PMCID: PMC7496227 DOI: 10.1002/jmri.27079] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 01/14/2020] [Accepted: 01/14/2020] [Indexed: 12/18/2022] Open
Abstract
Contrast‐enhanced MRI (CE‐MRI) is the most sensitive technique for breast cancer detection. Contrast‐enhanced mammography (CEM) is emerging as a possible alternative to CE‐MRI. Purpose To evaluate the diagnostic performance of a low radiation dose contrast‐enhanced mammography (L‐CEM) in women with suspicious findings on conventional imaging compared to CE‐MRI of the breast. Study Type Prospective, single center. Population Women with suspicious findings on mammography, tomosynthesis, or ultrasound, and no contraindications for L‐CEM or CE‐MRI. Eighty women were included. Field Strength/Sequence 1.5 and 3T CE‐MRI, standard protocol for breast, with dedicated coils, according to international guidelines. L‐CEM was performed using a dedicated prototype. Assessment Three, off‐site, blinded readers evaluated the images according to the BI‐RADS lexicon in a randomized order, each in two separate reading sessions. Histology served as a gold standard. Statistical Test Lesion detection rate, sensitivity, specificity, and negative and positive predictive values (NPV, PPV) were calculated and compared with multivariate statistics. Results Included were 80 women (mean age, 54.3 years ±11.2 standard deviation) with 93 lesions (32 benign, 61 malignant). The detection rate was significantly higher with CE‐MRI (92.5–94.6%; L‐CEM 79.6–91.4%, P = 0.014). Sensitivity (L‐CEM 65.6–90.2%; CE‐MRI 83.6–93.4%, P = 0.086) and NPV (L‐CEM 59.6–71.4%; CE‐MRI 63.0–76.5%, P = 0.780) did not differ between the modalities. Specificity (L‐CEM 46.9–96.9%; CE‐MRI 37.5–53.1%, P = 0.001) and PPV (L‐CEM 76.4–97.6%; CE‐MRI 73.3–77.3%, P = 0.007) were significantly higher with L‐CEM. Variations between readers were significant for sensitivity and NPV. The accuracy of L‐CEM was as good as CE‐MRI (75.3–76.3% vs. 72.0–75.3%, P = 0.514). Data Conclusion L‐CEM showed a high sensitivity and accuracy in women with suspicious findings on conventional imaging. Compared to CE‐MRI, L‐CEM has the potential to increase specificity and PPV. L‐CEM might help to reduce false‐positive biopsies while obtaining sensitivity comparable to that of CE‐MRI Level of Evidence 1 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2020;52:589–595.
Collapse
|
274
|
Baba K, Nomura M, Ohashi S, Hiratsuka T, Nakai Y, Saito T, Kondo Y, Fukuyama K, Kikuchi O, Yamada A, Matsubara J, Hirohashi K, Mitani Y, Mizumoto A, Muto M. Experimental model for the irradiation-mediated abscopal effect and factors influencing this effect. Am J Cancer Res 2020; 10:440-453. [PMID: 32195019 PMCID: PMC7061743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 12/26/2019] [Indexed: 06/10/2023] Open
Abstract
Radiotherapy (RT) is the primary treatment for cancer. Ionizing radiation from RT induces tumor damage at the irradiated site, and, although clinically infrequent, may cause regression of tumors distant from the irradiated site-a phenomenon known as the abscopal effect. Recently, the abscopal effect has been related to prolongation of overall survival time in cancer patients, though the factors that influence the abscopal effect are not well understood. The aim of this study is to clarify the factors influencing on abscopal effect. Here, we established a mouse model in which we induced the abscopal effect. We injected MC38 (mouse colon adenocarcinoma) cells subcutaneously into C57BL/6 mice at two sites. Only one tumor was irradiated and the sizes of both tumors were measured over time. The non-irradiated-site tumor showed regression, demonstrating the abscopal effect. This effect was enhanced by an increase in the irradiated-tumor volume and by administration of anti-PD1 antibody. When the abscopal effect was induced by a combination of RT and anti-PD1 antibody, it was also influenced by radiation dose and irradiated-tumor volume. These phenomena were also verified in other cell line, B16F10 cells (mouse melanoma cells). These findings provide further evidence of the mechanism for, and factors that influence, the abscopal effect in RT.
Collapse
|
275
|
Ren Z, Zhang X, Hu Z, Li D, Liu Z, Wei D, Jia Y, Yu N, Yu Y, Lei Y, Chen X, Guo C, Ren Z, He T. Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients. Acad Radiol 2020; 27:233-243. [PMID: 31031186 DOI: 10.1016/j.acra.2019.02.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 02/26/2019] [Accepted: 02/27/2019] [Indexed: 01/23/2023]
Abstract
OBJECTIVE To explore the feasibility of reducing radiation dose and improving image quality in CT portal venography (CTPV) using 80 kV and adaptive statistical iterative reconstruction-V(ASIR-V) in slender patients in comparison with conventional protocol using 120 kV and ASIR. METHODS Sixty slender patients for enhanced abdominal CT scanning were randomly divided into group A and group B. Group A used the conventional 120 kV tube voltage, 600 mgI/kg contrast dose and reconstructed with the recommended 40% ASIR. Group B used 80 kV tube voltage, 350 mgI/kg contrast dose and reconstructed with ASIR-V from 40% to 100% with 10% interval. The CT values and standard deviation (SD) values of the main portal vein, left branch, and right branch of portal vein, liver, and erector spinae at the same level were measured to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The image quality was subjectively scored by two experienced radiologists blindly using a 5-point criterion. The contrast dose, volumetric CT dose index, and dose length product were recorded in both groups and the effective dose was calculated. RESULTS There was no significant difference in general data between the two groups (p > 0.05), the effective dose and contrast dose in group B were reduced by 63.3% (p < 0.001) and 39.7% (p < 0.001), respectively compared with group A. With the percentage of ASIR-V increased in group B, the CT values showed no significant difference, while the SD values gradually decreased and SNR values and CNR values increased accordingly. Compared with group A, group B demonstrated similar CT values (p > 0.05), while the SD values with 80% ASIR-V to 100% ASIR-V were significantly lower than those of 40% ASIR (p < 0.001), and the SNR values and CNR values with 70% ASIR-V to 100% ASIR-V were significantly higher than those of 40% ASIR (p < 0.001). The subjective image quality scores by the two radiologists had excellent consistency (kappa value>0.75, p < 0.001), and the final subjective image quality scores and the subjective scores in each of the 5 scoring categories with 60% ASIR-V to 100% ASIR-V were all significantly higher than those of 40% ASIR, and 80% ASIR-V obtained the highest subjective score among different reconstructions. CONCLUSION In CTPV, the application of 80 kV and ASIR-V reconstruction in slender patients can significantly reduce radiation dose (by 63.3%) and contrast agent dose (by 39.7%). Compared with the recommended 40% ASIR using 120 kV, ASIR-V with 80% to 100% percentages can further improve image quality and with 80% ASIR-V being the best reconstruction algorithm. ADVANCES IN KNOWLEDGE CTPV with 80 kV and ASIR-V algorithm in slender patients can significantly reduce radiation dose and contrast agent dose as well as improve image quality, compared with the conventional 120 kV protocol using 40% ASIR.
Collapse
|