26
|
Nguyen KT, Xu NY, Buckingham BA, Chattaraj S, Cohen O, Heinemann L, Pickup J, Svensson J, Vigersky RA, Wong JC, Ziegler R. Improving the Patient Experience With Longer Wear Infusion Sets Symposium Report. J Diabetes Sci Technol 2022; 16:775-782. [PMID: 35227075 PMCID: PMC9294583 DOI: 10.1177/19322968221078884] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Continuous subcutaneous insulin infusion (CSII) therapy is becoming increasingly popular. CSII provides convenient insulin delivery, precise dosing, easy adjustments for physical activity, stress, or illness, and integration with continuous glucose monitors in hybrid or other closed-loop systems. However, even as insulin pump hardware and software have advanced, technology for insulin infusion sets (IISs) has stayed relatively stagnant over time and is often referred to as the "Achilles heel" of CSII. To discuss barriers to insulin pump therapy and present information about advancements in, and results from clinical trials of extended wear IISs, Diabetes Technology Society virtually hosted the "Improving the Patient Experience with Longer Wear Infusion Sets Symposium" on December 1, 2021. The symposium featured experts in the field of IISs, including representatives from Steno Diabetes Center Copenhagen, University of California San Francisco, Stanford University, Medtronic Diabetes, and Science Consulting in Diabetes. The webinar's seven speakers covered (1) advancements in insulin pump therapy, (2) efficacy of longer wear infusion sets, and (3) innovations to reduce plastics and insulin waste.
Collapse
|
27
|
Forlenza GP, Ekhlaspour L, DiMeglio LA, Fox LA, Rodriguez H, Shulman DI, Kaiserman KB, Liljenquist DR, Shin J, Lee SW, Buckingham BA. Glycemic outcomes of children 2-6 years of age with type 1 diabetes during the pediatric MiniMed™ 670G system trial. Pediatr Diabetes 2022; 23:324-329. [PMID: 35001477 PMCID: PMC9304187 DOI: 10.1111/pedi.13312] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 11/17/2021] [Accepted: 01/04/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Highly variable insulin sensitivity, susceptibility to hypoglycemia and inability to effectively communicate hypoglycemic symptoms pose significant challenges for young children with type 1 diabetes (T1D). Herein, outcomes during clinical MiniMed™ 670G system use were evaluated in children aged 2-6 years with T1D. METHODS Participants (N = 46, aged 4.6 ± 1.4 years) at seven investigational centers used the MiniMed™ 670G system in Manual Mode during a two-week run-in period followed by Auto Mode during a three-month study phase. Safety events, mean A1C, sensor glucose (SG), and percentage of time spent in (TIR, 70-180 mg/dl), below (TBR, <70 mg/dl) and above (TAR, >180 mg/dl) range were assessed for the run-in and study phase and compared using a paired t-test or Wilcoxon signed-rank test. RESULTS From run-in to end of study (median 87.1% time in auto mode), mean A1C and SG changed from 8.0 ± 0.9% to 7.5 ± 0.6% (p < 0.001) and from 173 ± 24 to 161 ± 16 mg/dl (p < 0.001), respectively. Overall TIR increased from 55.7 ± 13.4% to 63.8 ± 9.4% (p < 0.001), while TBR and TAR decreased from 3.3 ± 2.5% to 3.2 ± 1.6% (p = 0.996) and 41.0 ± 14.7% to 33.0 ± 9.9% (p < 0.001), respectively. Overnight TBR remained unchanged and TAR was further improved 12:00 am-6:00 am. Throughout the study phase, there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA) and no serious adverse device-related events. CONCLUSIONS At-home MiniMed™ 670G Auto Mode use by young children safely improved glycemic outcomes compared to two-week open-loop Manual Mode use. The improvements are similar to those observed in older children, adolescents and adults with T1D using the same system for the same duration of time.
Collapse
|
28
|
Ware J, Boughton CK, Allen JM, Wilinska ME, Tauschmann M, Denvir L, Thankamony A, Campbell FM, Wadwa RP, Buckingham BA, Davis N, DiMeglio LA, Mauras N, Besser REJ, Ghatak A, Weinzimer SA, Hood KK, Fox DS, Kanapka L, Kollman C, Sibayan J, Beck RW, Hovorka R, Hovorka R, Acerini CL, Thankamony A, Allen JM, Boughton CK, Dovc K, Dunger DB, Ware J, Musolino G, Tauschmann M, Wilinska ME, Hayes JF, Hartnell S, Slegtenhorst S, Ruan Y, Haydock M, Mangat J, Denvir L, Kanthagnany SK, Law J, Randell T, Sachdev P, Saxton M, Coupe A, Stafford S, Ball A, Keeton R, Cresswell R, Crate L, Cripps H, Fazackerley H, Looby L, Navarra H, Saddington C, Smith V, Verhoeven V, Bratt S, Khan N, Moyes L, Sandhu K, West C, Wadwa RP, Alonso G, Forlenza G, Slover R, Towers L, Berget C, Coakley A, Escobar E, Jost E, Lange S, Messer L, Thivener K, Campbell FM, Yong J, Metcalfe E, Allen M, Ambler S, Waheed S, Exall J, Tulip J, Buckingham BA, Ekhlaspour L, Maahs D, Norlander L, Jacobson T, Twon M, Weir C, Leverenz B, Keller J, Davis N, Kumaran A, Trevelyan N, Dewar H, Price G, Crouch G, Ensom R, Haskell L, Lueddeke LM, Mauras N, Benson M, Bird K, Englert K, Permuy J, Ponthieux K, Marrero-Hernandez J, DiMeglio LA, Ismail H, Jolivette H, Sanchez J, Woerner S, Kirchner M, Mullen M, Tebbe M, Besser REJ, Basu S, London R, Makaya T, Ryan F, Megson C, Bowen-Morris J, Haest J, Law R, Stamford I, Ghatak A, Deakin M, Phelan K, Thornborough K, Shakeshaft J, Weinzimer SA, Cengiz E, Sherr JL, Van Name M, Weyman K, Carria L, Steffen A, Zgorski M, Sibayan J, Beck RW, Borgman S, Davis J, Rusnak J, Hellman A, Cheng P, Kanapka L, Kollman C, McCarthy C, Chalasani S, Hood KK, Hanes S, Viana J, Lanning M, Fox DS, Arreaza-Rubin G, Eggerman T, Green N, Janicek R, Gabrielson D, Belle SH, Castle J, Green J, Legault L, Willi SM, Wysham C. Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial. Lancet Digit Health 2022; 4:e245-e255. [PMID: 35272971 DOI: 10.1016/s2589-7500(22)00020-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 12/10/2021] [Accepted: 01/25/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. METHODS In a multicentre, multinational, parallel randomised controlled trial, participants aged 6-18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0-10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. FINDINGS Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference -3·5 mmol/mol (95% CI -6·5 to -0·5 [-0·32 percentage points, -0·59 to -0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26-53]), but consistently high with CamAPS FX (93% [88-96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. INTERPRETATION The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. FUNDING National Institute of Diabetes and Digestive and Kidney Diseases.
Collapse
|
29
|
Tanenbaum ML, Ngo J, Hanes SJ, Basina M, Buckingham BA, Hessler D, Maahs DM, Mulvaney S, Hood KK. ONBOARD: A Feasibility Study of a Telehealth-Based Continuous Glucose Monitoring Adoption Intervention for Adults with Type 1 Diabetes. Diabetes Technol Ther 2021; 23:818-827. [PMID: 34270351 PMCID: PMC8819504 DOI: 10.1089/dia.2021.0198] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Background: Continuous glucose monitoring (CGM) can improve glycemic control for adults with type 1 diabetes (T1D) but certain barriers interfere with consistent use including cost, data overload, alarm fatigue, physical discomfort, and unwanted social attention. This pilot study aimed to examine feasibility and acceptability of a behavioral intervention, ONBOARD (Overcoming Barriers and Obstacles to Adopting Diabetes Devices) to support adults with T1D in optimizing CGM use. Methods: Adults (18-50 years) with T1D in their first year of CGM use were invited to participate in a tailored, multicomponent telehealth-based intervention delivered over four 60-min sessions every 2-3 weeks. Participants completed surveys (demographics; diabetes distress, Diabetes Distress Scale for adults with type 1 diabetes; satisfaction with program) and provided CGM data at baseline and postintervention (3 months). Data were analyzed using paired t-tests and Wilcoxon signed-rank tests. Results: Twenty-two participants (age = 30.95 ± 8.32 years; 59% women; 91% non-Hispanic; 86% White, 5% Black, 9% other; 73% pump users) completed the study. ONBOARD demonstrated acceptability and a high rate of retention. Moderate effect sizes were found for reductions in diabetes distress (P = 0.01, r = -0.37) and increases in daytime spent in target range (70-180 mg/dL: P = 0.03, r = -0.35). There were no significant increases in hypoglycemia. Conclusions: Findings show preliminary evidence of feasibility, acceptability, and efficacy of ONBOARD for supporting adults with T1D in optimizing CGM use while alleviating diabetes distress. Further research is needed to examine ONBOARD in a larger sample over a longer period.
Collapse
|
30
|
Maikawa CL, Chen PC, Vuong ET, Nguyen LT, Mann JL, d'Aquino AI, Lal RA, Maahs DM, Buckingham BA, Appel EA. Ultra-Fast Insulin-Pramlintide Co-Formulation for Improved Glucose Management in Diabetic Rats. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2101575. [PMID: 34499434 PMCID: PMC8564421 DOI: 10.1002/advs.202101575] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 07/07/2021] [Indexed: 05/04/2023]
Abstract
Dual-hormone replacement therapy with insulin and amylin in patients with type 1 diabetes has the potential to improve glucose management. Unfortunately, currently available formulations require burdensome separate injections at mealtimes and have disparate pharmacokinetics that do not mimic endogenous co-secretion. Here, amphiphilic acrylamide copolymers are used to create a stable co-formulation of monomeric insulin and amylin analogues (lispro and pramlintide) with synchronous pharmacokinetics and ultra-rapid action. The co-formulation is stable for over 16 h under stressed aging conditions, whereas commercial insulin lispro (Humalog) aggregates in 8 h. The faster pharmacokinetics of monomeric insulin in this co-formulation result in increased insulin-pramlintide overlap of 75 ± 6% compared to only 47 ± 7% for separate injections. The co-formulation results in similar delay in gastric emptying compared to pramlintide delivered separately. In a glucose challenge, in rats, the co-formulation reduces deviation from baseline glucose compared to insulin only, or separate insulin and pramlintide administrations. Further, comparison of interspecies pharmacokinetics of monomeric pramlintide suggests that pharmacokinetics observed for the co-formulation will be well preserved in future translation to humans. Together these results suggest that the co-formulation has the potential to improve mealtime glucose management and reduce patient burden in the treatment of diabetes.
Collapse
|
31
|
Tanenbaum ML, Messer LH, Wu CA, Basina M, Buckingham BA, Hessler D, Mulvaney SA, Maahs DM, Hood KK. Help when you need it: Perspectives of adults with T1D on the support and training they would have wanted when starting CGM. Diabetes Res Clin Pract 2021; 180:109048. [PMID: 34534592 PMCID: PMC8578423 DOI: 10.1016/j.diabres.2021.109048] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 08/30/2021] [Accepted: 09/09/2021] [Indexed: 10/20/2022]
Abstract
AIMS The purpose of this study was to explore preferences that adults with type 1 diabetes (T1D) have for training and support to initiate and sustain optimal use of continuous glucose monitoring (CGM) technology. METHODS Twenty-two adults with T1D (M age 30.95 ± 8.32; 59.1% female; 90.9% Non-Hispanic; 86.4% White; diabetes duration 13.5 ± 8.42 years; 72.7% insulin pump users) who had initiated CGM use in the past year participated in focus groups exploring two overarching questions: (1) What helped you learn to use your CGM? and (2) What additional support would you have wanted? Focus groups used a semi-structured interview guide and were recorded, transcribed and analyzed. RESULTS Overarching themes identified were: (1) "I got it going by myself": CGM training left to the individual; (2) Internet as diabetes educator, troubleshooter, and peer support system; and (3) domains of support they wanted, including content and format of this support. CONCLUSION This study identifies current gaps in training and potential avenues for enhancing device education and CGM onboarding support for adults with T1D. Providing CGM users with relevant, timely resources and attending to the emotional side of using CGM could alleviate the burden of starting a new device and promote sustained device use.
Collapse
|
32
|
Schoelwer MJ, Kanapka LG, Wadwa RP, Breton MD, Ruedy KJ, Ekhlaspour L, Forlenza GP, Cobry EC, Messer LH, Cengiz E, Jost E, Carria L, Emory E, Hsu LJ, Weinzimer SA, Buckingham BA, Lal RA, Oliveri MC, Kollman CC, Dokken BB, Cherñavvsky DR, Beck RW, DeBoer MD. Predictors of Time-in-Range (70-180 mg/dL) Achieved Using a Closed-Loop Control System. Diabetes Technol Ther 2021; 23:475-481. [PMID: 33689454 PMCID: PMC8252894 DOI: 10.1089/dia.2020.0646] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Background: Studies of closed-loop control (CLC) in patients with type 1 diabetes (T1D) consistently demonstrate improvements in glycemic control as measured by increased time-in-range (TIR) 70-180 mg/dL. However, clinical predictors of TIR in users of CLC systems are needed. Materials and Methods: We analyzed data from 100 children aged 6-13 years with T1D using the Tandem Control-IQ CLC system during a randomized trial or subsequent extension phase. Continuous glucose monitor data were collected at baseline and during 12-16 weeks of CLC use. Participants were stratified into quartiles of TIR on CLC to compare clinical characteristics. Results: TIR for those in the first, second, third, and fourth quartiles was 54%, 65%, 71%, and 78%, respectively. Lower baseline TIR was associated with lower TIR on CLC (r = 0.69, P < 0.001). However, lower baseline TIR was also associated with greater improvement in TIR on CLC (r = -0.81, P < 0.001). During CLC, participants in the highest versus lowest TIR-quartile administered more user-initiated boluses daily (8.5 ± 2.8 vs. 5.8 ± 2.6, P < 0.001) and received fewer automated boluses (3.5 ± 1.0 vs. 6.0 ± 1.6, P < 0.001). Participants in the lowest (vs. the highest) TIR-quartile received more insulin per body weight (1.13 ± 0.27 vs. 0.87 ± 0.20 U/kg/d, P = 0.008). However, in a multivariate model adjusting for baseline TIR, user-initiated boluses and insulin-per-body-weight were no longer significant. Conclusions: Higher baseline TIR is the strongest predictor of TIR on CLC in children with T1D. However, lower baseline TIR is associated with the greatest improvement in TIR. As with open-loop systems, user engagement is important for optimal glycemic control.
Collapse
|
33
|
Brown SA, Forlenza GP, Bode BW, Pinsker JE, Levy CJ, Criego AB, Hansen DW, Hirsch IB, Carlson AL, Bergenstal RM, Sherr JL, Mehta SN, Laffel LM, Shah VN, Bhargava A, Weinstock RS, MacLeish SA, DeSalvo DJ, Jones TC, Aleppo G, Buckingham BA, Ly TT. Multicenter Trial of a Tubeless, On-Body Automated Insulin Delivery System With Customizable Glycemic Targets in Pediatric and Adult Participants With Type 1 Diabetes. Diabetes Care 2021; 44:1630-1640. [PMID: 34099518 PMCID: PMC8323171 DOI: 10.2337/dc21-0172] [Citation(s) in RCA: 123] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 04/14/2021] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Advances in diabetes technology have transformed the treatment paradigm for type 1 diabetes, yet the burden of disease is significant. We report on a pivotal safety study of the first tubeless, on-body automated insulin delivery system with customizable glycemic targets. RESEARCH DESIGN AND METHODS This single-arm, multicenter, prospective study enrolled 112 children (age 6-13.9 years) and 129 adults (age 14-70 years). A 2-week standard therapy phase (usual insulin regimen) was followed by 3 months of automated insulin delivery. Primary safety outcomes were incidence of severe hypoglycemia and diabetic ketoacidosis. Primary effectiveness outcomes were change in HbA1c and percent time in sensor glucose range 70-180 mg/dL ("time in range"). RESULTS A total of 235 participants (98% of enrolled, including 111 children and 124 adults) completed the study. HbA1c was significantly reduced in children by 0.71% (7.8 mmol/mol) (mean ± SD: 7.67 ± 0.95% to 6.99 ± 0.63% [60 ± 10.4 mmol/mol to 53 ± 6.9 mmol/mol], P < 0.0001) and in adults by 0.38% (4.2 mmol/mol) (7.16 ± 0.86% to 6.78 ± 0.68% [55 ± 9.4 mmol/mol to 51 ± 7.4 mmol/mol], P < 0.0001). Time in range was improved from standard therapy by 15.6 ± 11.5% or 3.7 h/day in children and 9.3 ± 11.8% or 2.2 h/day in adults (both P < 0.0001). This was accomplished with a reduction in time in hypoglycemia <70 mg/dL among adults (median [interquartile range]: 2.00% [0.63, 4.06] to 1.09% [0.46, 1.75], P < 0.0001), while this parameter remained the same in children. There were three severe hypoglycemia events not attributable to automated insulin delivery malfunction and one diabetic ketoacidosis event from an infusion site failure. CONCLUSIONS This tubeless automated insulin delivery system was safe and allowed participants to significantly improve HbA1c levels and time in target glucose range with a very low occurrence of hypoglycemia.
Collapse
|
34
|
Cobry EC, Kanapka LG, Cengiz E, Carria L, Ekhlaspour L, Buckingham BA, Hood KK, Hsu LJ, Messer LH, Schoelwer MJ, Emory E, Ruedy KJ, Beck RW, Wadwa RP, Gonder-Frederick L. Health-Related Quality of Life and Treatment Satisfaction in Parents and Children with Type 1 Diabetes Using Closed-Loop Control. Diabetes Technol Ther 2021; 23:401-409. [PMID: 33404325 PMCID: PMC8215424 DOI: 10.1089/dia.2020.0532] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Introduction: Hybrid closed-loop systems increase time-in-range (TIR) and reduce glycemic variability. Person-reported outcomes (PROs) are essential to assess the utility of new devices and their impact on quality of life. This article focuses on the PROs for pediatric participants (ages 6-13 years) with type 1 diabetes (T1D) and their parents during a trial using the Tandem Control-IQ system, which was shown to increase TIR and improve other glycemic metrics. Research Design and Methods: One hundred and one children 6 to 13 years old with T1D were randomly assigned to closed-loop control (CLC) or sensor-augmented pump (SAP) in a 16-week randomized clinical trial with extension to 28 weeks during which the SAP group crossed over to CLC. Health-related quality of life and treatment satisfaction measures were obtained from children and their parents at baseline, 16 weeks, and 28 weeks. Results: Neither the children in the CLC group nor their parents had statistically significant changes in PRO outcomes compared with the SAP group at the end of the 16-week randomized controlled trial and the 28-week extension. Parents in the CLC group reported nonsignificant improvements in some PRO scores when compared with the SAP group at 16 weeks, which were sustained at 28 weeks. Sleep scores for parents improved from "poor sleep quality" to "adequate sleep quality" between baseline and 16 weeks, however, the change in scores was not statistically different between groups. Conclusions: Children with T1D who used the Control-IQ system did not experience increased burden compared with those using SAP based on person-reported outcomes from the children and their parents. Clinical Trials Registration: NCT03844789.
Collapse
|
35
|
Forlenza GP, Buckingham BA, Brown SA, Bode BW, Levy CJ, Criego AB, Wadwa RP, Cobry EC, Slover RJ, Messer LH, Berget C, McCoy S, Ekhlaspour L, Kingman RS, Voelmle MK, Boyd J, O'Malley G, Grieme A, Kivilaid K, Kleve K, Dumais B, Vienneau T, Huyett LM, Lee JB, O'Connor J, Benjamin E, Ly TT. First Outpatient Evaluation of a Tubeless Automated Insulin Delivery System with Customizable Glucose Targets in Children and Adults with Type 1 Diabetes. Diabetes Technol Ther 2021; 23:410-424. [PMID: 33325779 PMCID: PMC8215410 DOI: 10.1089/dia.2020.0546] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Background: The objective of this study was to assess the safety and effectiveness of the first commercial configuration of a tubeless automated insulin delivery system, Omnipod® 5, in children (6-13.9 years) and adults (14-70 years) with type 1 diabetes (T1D) in an outpatient setting. Materials and Methods: This was a single-arm, multicenter, prospective clinical study. Data were collected over a 14-day standard therapy (ST) phase followed by a 14-day hybrid closed-loop (HCL) phase, where participants (n = 36) spent 72 h at each of three prespecified glucose targets (130, 140, and 150 mg/dL, 9 days total) then 5 days with free choice of glucose targets (110-150 mg/dL) using the Omnipod 5. Remote safety monitoring alerts were enabled during the HCL phase. Primary endpoints were difference in time in range (TIR) (70-180 mg/dL) between ST and HCL phases and proportion of participants reporting serious device-related adverse events. Results: Mean TIR was significantly higher among children in the free-choice period overall (64.9% ± 12.2%, P < 0.01) and when using a 110 mg/dL target (71.2% ± 10.2%, P < 0.01), a 130 mg/dL target (61.5% ± 7.7%, P < 0.01), and a 140 mg/dL target (64.8% ± 11.6%, P < 0.01), and among adults using a 130 mg/dL target (75.1% ± 11.6%, P < 0.05), compared to the ST phase (children: 51.0% ± 13.3% and adults: 65.6% ± 15.7%). There were no serious device-related adverse events reported during the HCL phase, nor were there episodes of severe hypoglycemia or diabetic ketoacidosis. Conclusion: The Omnipod 5 System was safe and effective when used at glucose targets from 110 to 150 mg/dL for 14 days at home in children and adults with T1D.
Collapse
|
36
|
Buckingham BA, Forlenza GP, Criego AB, Hansen DW, Bode BW, Brown SA, MacLeish SA, Pinsker JE, DeSalvo DJ, Sherr JL, Mehta SN, Laffel LM, Bhargava A, Ly TT. Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D). J Endocr Soc 2021. [PMCID: PMC8090047 DOI: 10.1210/jendso/bvab048.927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Advances in diabetes technology have transformed the treatment paradigm for T1D, yet the burden of the disease remains significant. The pediatric population poses unique challenges to glucose management with unpredictable exercise and food consumption. The Omnipod 5 System is a novel hybrid closed-loop (HCL) system with fully on-body operation. A tubeless insulin pump (pod) containing a personalized Model Predictive Control algorithm communicates directly with a Dexcom G6 continuous glucose monitor (CGM, or sensor) to automate insulin delivery. Therapy customization is enabled through glucose targets from 110–150 mg/dL, adjustable by time of day, which is a critical component to individualize glucose management in children. We report on the first, pivotal outpatient safety evaluation of the Omnipod 5 System in a large cohort of children with T1D. Participants aged 6–13.9y with T1D≥6 months and A1C<10% used the HCL system for 3 months at home after a 14-day run-in phase of their standard therapy (ST, included both pump therapy and multiple daily injections). The primary safety and effectiveness endpoints, respectively, were occurrence of severe hypoglycemia (SH) and diabetic ketoacidosis (DKA), and change in A1C and sensor glucose percent time in target range (TIR) (70–180 mg/dL) during HCL compared with ST. Participants (N=112) were aged (mean±SD) 10.3±2.2y with T1D duration 4.7±2.6y and baseline A1C 7.7±0.9% (range 5.8–10.3%). TIR increased significantly from ST to HCL, from 52.5±15.6% to 68.0±8.1% (p<0.0001), corresponding to an additional 3.7 hours/day in target range. A1C at end of study was reduced by 0.7% to 7.0±0.6% (p<0.0001). Percentages of time in hyperglycemia were reduced: >180 mg/dL from 45.3±16.7% to 30.2±8.7% and ≥250 mg/dL from 19.1±13.1% to 9.6±5.4% (both p<0.0001). Percentages of time in hypoglycemia remained low from ST to HCL: <54 mg/dL from 0.4±0.8% to 0.3±0.3% and <70 mg/dL from 2.2±2.7% to 1.8±1.4% (both p>0.05). Mean glucose decreased from 183±32 to 160±15 mg/dL (p<0.0001). During the HCL phase there was 1 episode of SH (delayed eating after pre-meal bolus) and 1 episode of DKA (suspected infusion site failure) reported. Virtually all participants completing the pivotal study (99%) continued system use during an extension phase. In this multi-center pivotal study in a large cohort of children with T1D, the Omnipod 5 System was safe and effective when used for 3 months at home. There were significant improvements in both TIR and A1C, while time below range (<70 mg/dL) remained low. The beneficial glycemic outcomes are critical for children, given that neurologic outcomes can be negatively impacted by hyperglycemia. The current results and commitment to the extension phase emphasize the safe and effective use of the HCL system, as well as the preference for the Omnipod 5 System over participants’ previous therapy.
Collapse
|
37
|
Ekhlaspour L, Schoelwer MJ, Forlenza GP, DeBoer MD, Norlander L, Hsu L, Kingman R, Boranian E, Berget C, Emory E, Buckingham BA, Breton MD, Wadwa RP. Safety and Performance of the Tandem t:slim X2 with Control-IQ Automated Insulin Delivery System in Toddlers and Preschoolers. Diabetes Technol Ther 2021; 23:384-391. [PMID: 33226837 PMCID: PMC8080923 DOI: 10.1089/dia.2020.0507] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Background: Glycemic control is particularly challenging for toddlers and preschoolers with type 1 diabetes (T1D), and data on the use of closed-loop systems in this age range are limited. Materials and Methods: We studied use of a modified investigational version of the Tandem t:slim X2 Control-IQ system in children aged 2 to 5 years during 48 h in an outpatient supervised hotel (SH) setting followed by 3 days of home use to examine the safety of this system in young children. Meals and snacks were not restricted and boluses were estimated per parents' usual routine. At least 30 min of daily exercise was required during the SH phase. All participants were remotely monitored by study staff while on closed-loop in addition to monitoring by at least one parent throughout the study. Results: Twelve participants diagnosed with T1D for at least 3 months with mean age 4.7 ± 1.0 years (range 2.0-5.8 years) and hemoglobin A1c of 7.3% ± 0.8% were enrolled at three sites. With use of Control-IQ, the percentage of participants meeting our prespecified goals of less than 6% time below 70 mg/dL and less than 40% time above 180 mg/dL increased from 33% to 83%. Control-IQ use significantly improved percent time in range (70-180 mg/dL) compared to baseline (71.3 ± 12.5 vs. 63.7 ± 15.1, P = 0.016). All participants completed the study with no adverse events. Conclusions: In this brief pilot study, use of the modified Control-IQ system was safe in 2-5-year-old children with T1D and improved glycemic control.
Collapse
|
38
|
Lal RA, Maikawa CL, Lewis D, Baker SW, Smith AAA, Roth GA, Gale EC, Stapleton LM, Mann JL, Yu AC, Correa S, Grosskopf AK, Liong CS, Meis CM, Chan D, Garner JP, Maahs DM, Buckingham BA, Appel EA. Full closed loop open-source algorithm performance comparison in pigs with diabetes. Clin Transl Med 2021; 11:e387. [PMID: 33931977 PMCID: PMC8087942 DOI: 10.1002/ctm2.387] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 03/24/2021] [Accepted: 03/30/2021] [Indexed: 12/20/2022] Open
Abstract
Understanding how automated insulin delivery (AID) algorithm features impact glucose control under full closed loop delivery represents a critical step toward reducing patient burden by eliminating the need for carbohydrate entries at mealtimes. Here, we use a pig model of diabetes to compare AndroidAPS and Loop open‐source AID systems without meal announcements. Overall time‐in‐range (70–180 mg/dl) for AndroidAPS was 58% ± 5%, while time‐in‐range for Loop was 35% ± 5%. The effect of the algorithms on time‐in‐range differed between meals and overnight. During the overnight monitoring period, pigs had an average time‐in‐range of 90% ± 7% when on AndroidAPS compared to 22% ± 8% on Loop. Time‐in‐hypoglycemia also differed significantly during the lunch meal, whereby pigs running AndroidAPS spent an average of 1.4% (+0.4/−0.8)% in hypoglycemia compared to 10% (+3/−6)% for those using Loop. As algorithm design for closed loop systems continues to develop, the strategies employed in the OpenAPS algorithm (known as oref1) as implemented in AndroidAPS for unannounced meals may result in a better overall control for full closed loop systems.
Collapse
|
39
|
Isganaitis E, Raghinaru D, Ambler-Osborn L, Pinsker JE, Buckingham BA, Wadwa RP, Ekhlaspour L, Kudva YC, Levy CJ, Forlenza GP, Beck RW, Kollman C, Lum JW, Brown SA, Laffel LM. Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial. Diabetes Technol Ther 2021; 23:342-349. [PMID: 33216667 PMCID: PMC8080922 DOI: 10.1089/dia.2020.0572] [Citation(s) in RCA: 53] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14-24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9-16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference -12% [-2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference -0.7% [-10 min/day], 95% CI -1.0% to -0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI -0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Collapse
|
40
|
Kanapka LG, Wadwa RP, Breton MD, Ruedy KJ, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer MJ, Jost E, Carria L, Emory E, Hsu LJ, Weinzimer SA, DeBoer MD, Buckingham BA, Oliveri M, Kollman C, Dokken BB, Cherñavvsky D, Beck RW. Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes. Diabetes Care 2021; 44:473-478. [PMID: 33355258 PMCID: PMC7818334 DOI: 10.2337/dc20-1729] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 11/18/2020] [Indexed: 02/03/2023]
Abstract
OBJECTIVE To further evaluate the safety and efficacy of the Control-IQ closed-loop control (CLC) system in children with type 1 diabetes. RESEARCH DESIGN AND METHODS After a 16-week randomized clinical trial (RCT) comparing CLC with sensor-augmented pump (SAP) therapy in 101 children 6-13 years old with type 1 diabetes, 22 participants in the SAP group initiated use of the CLC system (referred to as SAP-CLC cohort), and 78 participants in the CLC group continued use of CLC (CLC-CLC cohort) for 12 weeks. RESULTS In the SAP-CLC cohort, mean percentage of time in range 70-180 mg/dL (TIR) increased from 55 ± 13% using SAP during the RCT to 65 ± 10% using CLC (P < 0.001), with 36% of the cohort achieving TIR >70% plus time <54 mg/dL <1% compared with 14% when using SAP (P = 0.03). Substantial improvement in TIR was seen after the 1st day of CLC. Time <70 mg/dL decreased from 1.80% to 1.34% (P < 0.001). In the CLC-CLC cohort, mean TIR increased from 53 ± 17% prerandomization to 67 ± 10% during the RCT and remained reasonably stable at 66 ± 10% through the 12 weeks post-RCT. No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either cohort. CONCLUSIONS This further evaluation of the Control-IQ CLC system supports the findings of the preceding RCT that use of a closed-loop system can safely improve glycemic control in children 6-13 years old with type 1 diabetes from the 1st day of use and demonstrates that these improvements can be sustained through 28 weeks of use.
Collapse
|
41
|
Maikawa CL, d'Aquino AI, Lal RA, Buckingham BA, Appel EA. Engineering biopharmaceutical formulations to improve diabetes management. Sci Transl Med 2021; 13:eabd6726. [PMID: 33504649 PMCID: PMC8004356 DOI: 10.1126/scitranslmed.abd6726] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Accepted: 12/22/2020] [Indexed: 12/12/2022]
Abstract
Insulin was first isolated almost a century ago, yet commercial formulations of insulin and its analogs for hormone replacement therapy still fall short of appropriately mimicking endogenous glycemic control. Moreover, the controlled delivery of complementary hormones (such as amylin or glucagon) is complicated by instability of the pharmacologic agents and complexity of maintaining multiple infusions. In this review, we highlight the advantages and limitations of recent advances in drug formulation that improve protein stability and pharmacokinetics, prolong drug delivery, or enable alternative dosage forms for the management of diabetes. With controlled delivery, these formulations could improve closed-loop glycemic control.
Collapse
|
42
|
Cortez FDJ, Gebhart D, Robinson PV, Seftel D, Pourmandi N, Owyoung J, Bertozzi CR, Wilson DM, Maahs DM, Buckingham BA, Mills JR, Roforth MM, Pittock SJ, McKeon A, Page K, Wolf WA, Sanda S, Speake C, Greenbaum CJ, Tsai CT. Sensitive detection of multiple islet autoantibodies in type 1 diabetes using small sample volumes by agglutination-PCR. PLoS One 2020; 15:e0242049. [PMID: 33186361 PMCID: PMC7665791 DOI: 10.1371/journal.pone.0242049] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 10/21/2020] [Indexed: 02/07/2023] Open
Abstract
Islet autoantibodies are predominantly measured by radioassay to facilitate risk assessment and diagnosis of type 1 diabetes. However, the reliance on radioactive components, large sample volumes and limited throughput renders radioassay testing costly and challenging. We developed a multiplex analysis platform based on antibody detection by agglutination-PCR (ADAP) for the sample-sparing measurement of GAD, IA-2 and insulin autoantibodies/antibodies in 1 μL serum. The assay was developed and validated in 7 distinct cohorts (n = 858) with the majority of the cohorts blinded prior to analysis. Measurements from the ADAP assay were compared to radioassay to determine correlation, concordance, agreement, clinical sensitivity and specificity. The average overall agreement between ADAP and radioassay was above 91%. The average clinical sensitivity and specificity were 96% and 97%. In the IASP 2018 workshop, ADAP achieved the highest sensitivity of all assays tested at 95% specificity (AS95) rating for GAD and IA-2 autoantibodies and top-tier performance for insulin autoantibodies. Furthermore, ADAP correctly identified 95% high-risk individuals with two or more autoantibodies by radioassay amongst 39 relatives of T1D patients tested. In conclusion, the new ADAP assay can reliably detect the three cardinal islet autoantibodies/antibodies in 1μL serum with high sensitivity. This novel assay may improve pediatric testing compliance and facilitate easier community-wide screening for islet autoantibodies.
Collapse
|
43
|
Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer M, Ruedy KJ, Jost E, Carria L, Emory E, Hsu LJ, Oliveri M, Kollman CC, Dokken BB, Weinzimer SA, DeBoer MD, Buckingham BA, Cherñavvsky D, Wadwa RP. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes. N Engl J Med 2020; 383:836-845. [PMID: 32846062 PMCID: PMC7920146 DOI: 10.1056/nejmoa2004736] [Citation(s) in RCA: 242] [Impact Index Per Article: 60.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).
Collapse
|
44
|
Brown SA, Beck RW, Raghinaru D, Buckingham BA, Laffel LM, Wadwa RP, Kudva YC, Levy CJ, Pinsker JE, Dassau E, Doyle FJ, Ambler-Osborn L, Anderson SM, Church MM, Ekhlaspour L, Forlenza GP, Levister C, Simha V, Breton MD, Kollman C, Lum JW, Kovatchev BP. Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial. Diabetes Care 2020; 43:1822-1828. [PMID: 32471910 PMCID: PMC7372060 DOI: 10.2337/dc20-0124] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 04/29/2020] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14-72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70-180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = -6.0%; 95% CI -8.4%, -3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI -0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference -0.34% [-3.7 mmol/mol]; 95% CI -0.57% [-6.2 mmol/mol], -0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Collapse
|
45
|
Maikawa CL, Smith AAA, Zou L, Roth GA, Gale EC, Stapleton LM, Baker SW, Mann JL, Yu AC, Correa S, Grosskopf AK, Liong CS, Meis CM, Chan D, Troxell M, Maahs DM, Buckingham BA, Webber MJ, Appel EA. A co-formulation of supramolecularly stabilized insulin and pramlintide enhances mealtime glucagon suppression in diabetic pigs. Nat Biomed Eng 2020; 4:507-517. [PMID: 32393892 PMCID: PMC7274092 DOI: 10.1038/s41551-020-0555-4] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 04/03/2020] [Indexed: 02/06/2023]
Abstract
Treatment of patients with diabetes with insulin and pramlintide (an amylin analogue) is more effective than treatment with insulin only. However, because mixtures of insulin and pramlintide are unstable and have to be injected separately, amylin analogues are only used by 1.5% of people with diabetes needing rapid-acting insulin. Here, we show that the supramolecular modification of insulin and pramlintide with cucurbit[7]uril-conjugated polyethylene glycol improves the pharmacokinetics of the dual-hormone therapy and enhances postprandial glucagon suppression in diabetic pigs. The co-formulation is stable for over 100 h at 37 °C under continuous agitation, whereas commercial formulations of insulin analogues aggregate after 10 h under similar conditions. In diabetic rats, the administration of the stabilized co-formulation increased the area-of-overlap ratio of the pharmacokinetic curves of pramlintide and insulin from 0.4 ± 0.2 to 0.7 ± 0.1 (mean ± s.d.) for the separate administration of the hormones. The co-administration of supramolecularly stabilized insulin and pramlintide better mimics the endogenous kinetics of co-secreted insulin and amylin, and holds promise as a dual-hormone replacement therapy.
Collapse
|
46
|
Mazaika PK, Marzelli M, Tong G, Foland-Ross LC, Buckingham BA, Aye T, Reiss AL. Functional near-infrared spectroscopy detects increased activation of the brain frontal-parietal network in youth with type 1 diabetes. Pediatr Diabetes 2020; 21:515-523. [PMID: 32003523 DOI: 10.1111/pedi.12992] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 01/16/2020] [Accepted: 01/24/2020] [Indexed: 12/30/2022] Open
Abstract
When considered as a group, children with type 1 diabetes have subtle cognitive deficits relative to neurotypical controls. However, the neural correlates of these differences remain poorly understood. Using functional near-infrared spectroscopy (fNIRS), we investigated the brain functional activations of young adolescents (19 individuals with type 1 diabetes, 18 healthy controls, ages 8-16 years) during a Go/No-Go response inhibition task. Both cohorts had the same performance on the task, but the individuals with type 1 diabetes subjects had higher activations in a frontal-parietal network including the bilateral supramarginal gyri and bilateral rostrolateral prefrontal cortices. The activations in these regions were positively correlated with fewer parent-reported conduct problems (ie, lower Conduct Problem scores) on the Behavioral Assessment System for Children, Second Edition. Lower Conduct Problem scores are characteristic of less rule-breaking behavior suggesting a link between this brain network and better self-control. These findings are consistent with a large functional magnetic resonance imaging (fMRI) study of children with type 1 diabetes using completely different participants. Perhaps surprisingly, the between-group activation results from fNIRS were statistically stronger than the results using fMRI. This pilot study is the first fNIRS investigation of executive function for individuals with type 1 diabetes. The results suggest that fNIRS is a promising functional neuroimaging resource for detecting the brain correlates of behavior in the pediatric clinic.
Collapse
|
47
|
Tanenbaum ML, Iturralde E, Hanes SJ, Suttiratana SC, Ambrosino JM, Ly TT, Maahs DM, Naranjo D, Walders-Abramson N, Weinzimer SA, Buckingham BA, Hood KK. Trust in hybrid closed loop among people with diabetes: Perspectives of experienced system users. J Health Psychol 2020; 25:429-438. [PMID: 28810490 PMCID: PMC7162558 DOI: 10.1177/1359105317718615] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Automated closed loop systems will greatly change type 1 diabetes management; user trust will be essential for acceptance of this new technology. This qualitative study explored trust in 32 individuals following a hybrid closed loop trial. Participants described how context-, system-, and person-level factors influenced their trust in the system. Participants attempted to override the system when they lacked trust, while trusting the system decreased self-management burdens and decreased stress. Findings highlight considerations for fostering trust in closed loop systems. Systems may be able to engage users by offering varying levels of controls to match trust preferences.
Collapse
|
48
|
Sherr JL, Buckingham BA, Forlenza GP, Galderisi A, Ekhlaspour L, Wadwa RP, Carria L, Hsu L, Berget C, Peyser TA, Lee JB, O'Connor J, Dumais B, Huyett LM, Layne JE, Ly TT. Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes Over 5 Days Under Free-Living Conditions. Diabetes Technol Ther 2020; 22:174-184. [PMID: 31596130 PMCID: PMC7047109 DOI: 10.1089/dia.2019.0286] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an investigational device. Materials and Methods: A 96-h hybrid closed-loop (HCL) study was conducted in a supervised hotel/rental home setting following a 7-day outpatient standard therapy (ST) phase. Eligible participants were aged 6-65 years with A1C <10.0% using insulin pump therapy or multiple daily injections. Meals during HCL were unrestricted, with boluses administered per usual routine. There was daily physical activity. The primary endpoints were percentage of time with sensor glucose <70 and ≥250 mg/dL. Results: Participants were 11 adults, 10 adolescents, and 15 children aged (mean ± standard deviation) 28.8 ± 7.9, 14.3 ± 1.3, and 9.9 ± 1.0 years, respectively. Percentage time ≥250 mg/dL during HCL was 4.5% ± 4.2%, 3.5% ± 5.0%, and 8.6% ± 8.8% per respective age group, a 1.6-, 3.4-, and 2.0-fold reduction compared to ST (P = 0.1, P = 0.02, and P = 0.03). Percentage time <70 mg/dL during HCL was 1.9% ± 1.3%, 2.5% ± 2.0%, and 2.2% ± 1.9%, a statistically significant decrease in adults when compared to ST (P = 0.005, P = 0.3, and P = 0.3). Percentage time 70-180 mg/dL increased during HCL compared to ST, reaching significance for adolescents and children: HCL 73.7% ± 7.5% vs. ST 68.0% ± 15.6% for adults (P = 0.08), HCL 79.0% ± 12.6% vs. ST 60.6% ± 13.4% for adolescents (P = 0.01), and HCL 69.2% ± 13.5% vs. ST 54.9% ± 12.9% for children (P = 0.003). Conclusions: The Omnipod personalized MPC algorithm was safe and performed well over 5 days and 4 nights of use by a cohort of participants ranging from youth aged ≥6 years to adults with T1D under supervised free-living conditions with challenges, including daily physical activity and unrestricted meals.
Collapse
|
49
|
Ekhlaspour L, Nally LM, El-Khatib FH, Ly TT, Clinton P, Frank E, Tanenbaum ML, Hanes SJ, Selagamsetty RR, Hood K, Damiano ER, Buckingham BA. Feasibility Studies of an Insulin-Only Bionic Pancreas in a Home-Use Setting. J Diabetes Sci Technol 2019; 13:1001-1007. [PMID: 31470740 PMCID: PMC6835195 DOI: 10.1177/1932296819872225] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND We tested the safety and performance of the "insulin-only" configuration of the bionic pancreas (BP) closed-loop blood-glucose control system in a home-use setting to assess glycemic outcomes using different static and dynamic glucose set-points. METHOD This is an open-label non-randomized study with three consecutive intervention periods. Participants had consecutive weeks of usual care followed by the insulin-only BP with (1) an individualized static set-point of 115 or 130 mg/dL and (2) a dynamic set-point that automatically varied within 110 to 130 mg/dL, depending on hypoglycemic risk. Human factors (HF) testing was conducted using validated surveys. The last five days of each study arm were used for data analysis. RESULTS Thirteen participants were enrolled with a mean age of 28 years, mean A1c of 7.2%, and mean daily insulin dose of 0.6 U/kg (0.4-1.0 U/kg). The usual care arm had an average glucose of 145 ± 20 mg/dL, which increased in the static set-point arm (159 ± 8 mg/dL, P = .004) but not in the dynamic set-point arm (154 ± 10 mg/dL, P = ns). There was no significant difference in time spent in range (70-180 mg/dL) among the three study arms. There was less time <70 mg/dL with both the static (1.8% ± 1.4%, P = .009) and dynamic set-point (2.7±1.5, P = .051) arms compared to the usual-care arm (5.5% ± 4.2%). HF testing demonstrated preliminary user satisfaction and no increased risk of diabetes burden or distress. CONCLUSIONS The insulin-only configuration of the BP using either static or dynamic set-points and initialized only with body weight performed similarly to other published insulin-only systems.
Collapse
|
50
|
Brown SA, Kovatchev BP, Raghinaru D, Lum JW, Buckingham BA, Kudva YC, Laffel LM, Levy CJ, Pinsker JE, Wadwa RP, Dassau E, Doyle FJ, Anderson SM, Church MM, Dadlani V, Ekhlaspour L, Forlenza GP, Isganaitis E, Lam DW, Kollman C, Beck RW. Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes. N Engl J Med 2019; 381:1707-1717. [PMID: 31618560 PMCID: PMC7076915 DOI: 10.1056/nejmoa1907863] [Citation(s) in RCA: 556] [Impact Index Per Article: 111.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
BACKGROUND Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes. METHODS In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring. RESULTS A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).
Collapse
|