26
|
Zhen YB, Guo XL, Xu B, Zhao HW, Xu CJ. Gene expression profiling analysis of the role of miR-22 in clear cell ovarian cancer. Neoplasma 2019; 63:856-864. [PMID: 27565323 DOI: 10.4149/neo_2016_604] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This study aimed to investigate the role and potential mechanism of miR-22 in clear cell ovarian cancer (CCOC) progression. The gene expression profile of GSE16568, including 3 CCOC samples with miR-22 overexpression and 3 negative controls, was downloaded from the Gene Expression Omnibus database. Differentially expressed genes (DEGs) were screened using the limma package in R. Gene Ontology (GO) and pathway enrichment analysis of DEGs were performed by using The Database for Annotation, Visualization and Integrated Discovery (DAVID). Furthermore, protein-protein interaction (PPI) network of the DEGs was constructed using the Search Tool for the Retrieval of Interacting Genes (STRING) database. Besides, the miR-22-mRNA interaction pairs were predicted to explore the critical genes involved in the cancer. Totally, 95 up-regulated DEGs and 51 down-regulated DEGs were identified. The DEGs were enriched in different GO terms and pathways. The up-regulated genes cyclin-dependent kinases (CDK6), MDM2 oncogene, E3 ubiquitin protein ligase (MDM2), and thrombospondin 1 (THBS1) were involved in the p53 signaling pathway. The up-regulated gene FBJ murine osteosarcoma viral oncogene homolog (FOS) was a hub protein in the PPI network of the DEGs. The down-regulated DEGs including lymphoid enhancer-binding factor 1 (LEF1) and v-myb avian myeloblastosis viral oncogene homolog (MYB) were mainly associated with immunity. Nine DEGs as target genes were identified to be recognized by miR-22. Our study suggested that several key genes such as CDK6, MDM2, LEF1, MYB, and FOS that involved in different pathways including p53 signaling pathway were associated with CCOC progression. miR-22 may play an essential role in cell migration and invasion in CCOC through targeting responsive genes.
Collapse
|
27
|
Zhao HW, Sun LT, Guo JW, Zhang WH, Lu W, Wu W, Wu BM, Sabbi G, Juchno M, Hafalia A, Ravaioli E, Xie DZ. Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:052301. [PMID: 29864795 DOI: 10.1063/1.5017479] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.
Collapse
|
28
|
Ma ZC, Du XJ, Zhao HW, Ma XX, Jiang DY, Liu Y, Ren LQ. Note: Motor-piezoelectricity coupling driven high temperature fatigue device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:016102. [PMID: 29390676 DOI: 10.1063/1.4998264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The design and performance evaluation of a novel high temperature fatigue device simultaneously driven by servo motor and piezoelectric actuator is our focus. The device integrates monotonic and cyclic loading functions with a maximum tensile load of 1800 N, driving frequency of 50 Hz, alternating load of 95 N, and maximum service temperature of 1200 °C. Multimodal fatigue tests with arbitrary combinations of static and dynamic loads are achieved. At temperatures that range from RT to 1100 °C, the tensile and tensile-fatigue coupling mechanical behaviors of UM Co50 alloys are investigated to verify the feasibility of the device.
Collapse
|
29
|
Liu H, Wang HY, Liu JB, Zhao HW, Zhou YY, Li LH. [Relationship between large artery elasticity function and coronary heart disease, lower extremity arterial disease in patients with carotid plaque]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2017; 49:1027-1033. [PMID: 29263476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVE To evaluate the relationship between large artery elastic function and coronary heart disease (CHD) or lower extremity arterial disease (LEAD) in patients with carotid plaque. METHODS A total of 491 patients with carotid plaque were enrolled into the study with complete data of arterial stiffness detection and blood test [male: 208 and female: 283, and mean age: (61.66±11.60) years]. All the subjects were divided into 2 groups according to CHD or LEAD, namely non-CHD&LEAD group (neither CHD nor LEAD) and CHD/LEAD group (either CHD or LEAD). Accor-ding to the mean age level (age<61.66 years or age>61.66 years), the independent association was analyzed between higher large arterial stiffness (carotid-femoral pulse wave velocity, CF-PWV, CF-PWV>9 m/s) and CHD/LEAD. RESULTS In the present research population, the mean level of arterial stiff-ness was high (the mean CF-PWV was 10.71 m/s), and 76.6% of them had arteriosclerosis, and 36.9% CHD/LEAD. The age, male and smoking proportion, systolic blood pressure (SBP), glycosylated hemoglobin (HbA1c), homocysteine (Hcy), creatinine (Cr), CF-PWV, prevalence rate of hypertension and diabetes mellitus, medication on hypertension, diabetes and hyperlipidemia were higher in CHD/LEAD group, and total cholesterol (TC), high density lipoprotein cholesterol (HDL-C), and low density lipoprotein cholesterol (LDL-C) were lower in CHD/LEAD group than in non-CHD&LEAD group (all P<0.05).In multivariate Logistic regression analysis, the results showed that in the patients with age below 61.66 years, large artery stiffness (CF-PWV>9 m/s) was an independent risk factor of CHD/LEAD (OR=3.229, 95%CI 1.156-9.022, P<0.05); In the patients with age above 61.66 years, there was no independent association between large artery stiffness and CHD/LEAD (P>0.05). CONCLUSION The large artery elasticity function in the patients with carotid plaque was poor. In the patients with carotid plaque and higher large artery stiffness below 61.66 years, the risk of the prevalence of CHD/LEAD was increased significantly than with normal arterial stiffness. In the patients with carotid plaque below or above 61.66 years, the independent influencing factors on the prevalence of CHD/LEAD were different.
Collapse
|
30
|
Hou HT, Qiu YM, Zhao HW, Li DH, Liu YT, Wang YZ, Su SH. [Effect of curcumin on intestinal mucosal mechanical barrier in rats with non-alcoholic fatty liver disease]. ZHONGHUA GAN ZANG BING ZA ZHI = ZHONGHUA GANZANGBING ZAZHI = CHINESE JOURNAL OF HEPATOLOGY 2017; 25:134-138. [PMID: 28297801 DOI: 10.3760/cma.j.issn.1007-3418.2017.02.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the effect of curcumin on intestinal mucosal mechanical barrier in rats with non-alcoholic fatty liver disease. Methods: A total of 30 male Sprague-Dawley rats were equally divided into normal control group, model group, and curcumin intervention group. The rats in the model group and the curcumin intervention group were given high-fat feed for 16 weeks, and those in the curcumin intervention group were given curcumin 200 mg/kg/day by gavage once a day after 8 weeks of high-fat feeding. The rats were sacrificed at the end of week 16. A light microscope was used to observe pathological changes in the liver, an electron microscope was used to observe the tight junction of the intestinal mucosa, an automatic biochemical analyzer was used to measure the serum levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST), chromogenic substrate Limulus amebocyte lysate assay was used to measure plasma lipopolysaccharide (LPS) level, spectrophotometric method was used to measure the activity of serum diamine oxidase, ELISA was used to measure the serum level of tumor necrosis factor-α (TNFα), and immunohistochemistry was used to measure the expression of the tight junction protein occludin. One-way ANOVA test and SNK-q test were used for statistical analysis. Results: Under the light microscope, the control group had no hepatocyte steatosis, the model group had significant hepatocyte steatosis and inflammatory cell infiltration, and the curcumin intervention group had reduced hepatocyte steatosis and inflammatory cell infiltration. Under the electron microscope, the control group had a clear and complete structure of the tight junction of the intestinal mucosa and normal structures of mitochondria and endoplasmic reticulum; in the model group, the structure of the tight junction of the intestinal mucosa was destroyed, the intercellular space was widened, the desmosomes had a loose structure, there was edema in some mitochondria, and the endoplasmic reticulum was dilated; the curcumin intervention group had improvements in the structure of tight junction of the intestinal mucosa, intercellular space, edema in the mitochondria, and dilation of the endoplasmic reticulum. Compared with the control group, the model group had significant increases in the serum levels of AST, ALT, DAO, TNFα, and LPS (q = -15.918, -14.402, -33.700, -8.944, and -10.832, P < 0.05); compared with the model group, the curcumin intervention group had significant reductions in the serum levels of AST, ALT, DAO, TNFα, and LPS (q = 10.457, 7.752, 18.802, 5.202, and 4.279, P < 0.05). In the control group, occludin showed a linear distribution along the top of small intestinal mucosal epithelial cells. The model group had a significant reduction in positive staining compared with the control group, and the curcumin intervention group had a significant increase in positive staining compared with the model group. The relative expression of occludin was 0.29±0.03 in the control group, 0.12±0.02 in the model group, and 0.21±0.02 in the curcumin intervention group (P < 0.05). Conclusion: Intestinal mucosal mechanical barrier is impaired in rats with NAFLD. Curcumin can reduce such damage, and its mechanism of action may be related to up-regulating the expression of occludin in the intestinal mucosa and reducing the levels of TNFα and LPS.
Collapse
|
31
|
Wang BS, Zhao HW, Qiao LX, Shan JQ, Hou QS, Chen DX, Guo HL. [Effect of Δ40p53 isoform on enhancing the pro-apoptotic function of p53 in tumor cells]. ZHONGHUA ZHONG LIU ZA ZHI [CHINESE JOURNAL OF ONCOLOGY] 2017; 39:332-338. [PMID: 28535648 DOI: 10.3760/cma.j.issn.0253-3766.2017.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the effect of Δ40p53, an alternative spliced isoform of p53 lacking the N-ter minus, on the pro-apoptotic function of p53. Methods: The wild-type p53 was ectopically expressed in HCT116-p53(-/-) (endogenous Δ40p53 expression), HCT116-p53(+ /+) (wild-type p53) and H1299 (p53-null) cells by adenoviral delivery, while Δ40p53 plasmid were transfected into these cells to overexpress Δ40p53. The levels of Δ40p53 and p53 mRNA were detected by reverse transcription-polymerase chain reaction (RT-PCR) and quantitative PCR. The expression of related proteins was deter mined by Western blotting. The interaction of p53 and Δ40p53 was observed by co-immunoprecipitation assay. Calcein-AM/propidium iodide (PI) staining and flow cytometry were used to detect the apoptotic rate of tested cells in each group. Results: HCT116-p53(-/-) cells expressed endogenous Δ40p53 isoform. Neither transcription nor protein expression of wild-type p53 was interfered by the increased expression of Δ40p53. Full length p53 and Δ40p53 could bind to each other. Calcein-AM/PI staining showed that the apoptotic rates of H1299-Control, HCT116-p53(-/-) -Control, H1299+ p53, HCT116-p53(-/-)+ p53, H1299+ oxaliplatin (Oxa), HCT116-p53(-/-)+ Oxa, H1299+ p53+ Oxa and HCT116-p53(-/-)+ p53+ Oxa groups were (2.50±0.47)%, (2.40±0.32)%, (5.20±0.58)%, (4.10±0.18)%, (22.40±1.73)%, (19.30±1.11)%, (29.90±1.15)% and (39.30±2.26)%, respectively. It was statistically significant between H1299+ p53+ Oxa and HCT116-p53(-/-)+ p53+ Oxa groups (t=3.721, P=0.0205). Moreover, the apoptotic rates of H1299-Control, H1299+ Δ40p53, H1299+ p53, H1299+ p53+ Δ40p53, H1299+ Oxa, H1299+ Δ40p53+ Oxa, H1299+ p53+ Oxa and H1299+ p53+ Δ40p53+ Oxa groups were (2.60±0.35)%, (2.20±0.17)%, (4.80±0.49)%, (4.90±1.10)%, (20.30±1.10)%, (19.60±1.45)%, (27.90±1.39)%, (35.20±1.43)%, respectively. Furthermore, flow cytometry assay showed that the apoptotic rates of above cells were (2.70±0.32)%, (2.20±0.24)%, (4.60±0.48)%, (3.90±0.67)%, (19.30±1.11)%, (17.70±0.66)%, (28.30±2.76)% and (37.50±1.51)%, respectively. H1299+ p53+ Δ40p53+ Oxa cells showed higher cell apoptosis than H1299+ p53+ Oxa cells (t=2.930, P=0.042). Conclusion: Δ40p53 isoform can bind to full-length p53, and enhance its pro-apoptotic function in tumor cells.
Collapse
|
32
|
Liu Y, Dai B, Su J, Peng Y, Tan W, Zhao HW. [Effect of home noninvasive positive pressure ventilation on patients with severe stable chronic obstructive pulmonary disease: a meta-analysis]. ZHONGHUA JIE HE HE HU XI ZA ZHI = ZHONGHUA JIEHE HE HUXI ZAZHI = CHINESE JOURNAL OF TUBERCULOSIS AND RESPIRATORY DISEASES 2017; 40:354-362. [PMID: 28482421 DOI: 10.3760/cma.j.issn.1001-0939.2017.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Objective: To evaluate the effect of home noninvasive positive pressure ventilation (NPPV) on patients with severe stable chronic obstructive pulmonary disease(COPD) by meta-analysis. Methods: The data of this meta-analysis was retrieved from the PubMed, EMBASE, Cochrane library, Wanfang, Weipu and CNKI databases from January 1980 to January 2016. Randomized controlled trials (RCTs) on comparison of the effect of home NPPV in patients with severe stable COPD were enrolled. The enrolled data were divided into different subgroups in terms of the levels of inspiratory positive airway pressure(IPAP), different duration of ventilation per day, and different levels of baseline hypercapnia on change in PaCO(2). Meta-analysis was performed to compare the effect of different subgroups by RevMan 5.3. Results: Ten studies with a total of 789 patients were included. Home NPPV improved 6-minute walk distance (WMD: -45.12, 95%CI: -85.39--4.85, P=0.03) and forced expiratory volume in the first second [standard mean difference(SMD): -0.26, 95%CI: -0.51--0.02, P=0.03]after 1 year of ventilation, but did not improve the mortality, PaCO(2,)PaO(2,)pH, FVC, maximal inspiratory pressure (MIP), FEV(1)/FVC, maximal voluntary ventilation(MVV) total sleep time, sleep efficiency and the proportion of rapid eye movement (REM) sleep. Subgroup analysis showed that home NPPV can significantly reduce the PaCO(2) in patients ventilated with 18 cmH(2)O(1 cmH(2)O=0.098 kPa) and higher IPAP levels than those with lower IPAP levels (SMD: -0.6, 95%CI: -1.09--0.12, P=0.01), and in patients with NPPV for at least 5 h per day and those with lower duration (SMD: -0.45, 95%CI: -0.87--0.02, P=0.04), and in patients with baseline PaCO(2) of at least 55 mmHg (1 mmHg=0.133 kPa) (SMD: -0.69, 95%CI: -1.07--0.31, P=0.00) than those with lower levels. Conclusions: Home NPPV can improve 6MWD and FEV(1) in severe stable COPD patients but does not improve the mortality, gas exchange and sleep efficiency. Patients may gain more benefits when using higher IPAP levels, longer ventilation per day and in those with higher baseline PaCO(2).
Collapse
|
33
|
Wu YQ, Shen J, Zhou QL, Zhao HW, Liu LR, Liu X. Interleukin-6 and interleukin-8 in diagnosing neonatal septicemia. J BIOL REG HOMEOS AG 2016; 30:1107-1113. [PMID: 28078861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Neonatal septicemia (NS) is a common cause of death of newborn infants, hence early diagnosis and treatment are of the utmost importance. However, lack of specific clinical symptoms and late detection delay a correct diagnosis. It is therefore of great importance to establish auxiliary indexes for the early diagnosis of NS. To evaluate the value of interleukin (IL-6 and IL-8) in the diagnosis of NS, a prospective study was carried out. Seventy-five newborns who developed septicemia and received treatment in our hospital from January 2013 to December 2014 were selected as research subjects; also, 50 healthy newborns were set as a control group. The levels of serum IL-6 and IL-8 were compared between the two groups. Results demonstrated that levels of C-reactive protein (CRP), IL-6 and IL-8 of the septicemia group were higher than those of the control group on admission, although the difference had no statistical significance (P less than 0.05); the septicemia group had higher sequential organ failure assessment (SOFA) scores but lower pediatric critical illness scores (PCIS) compared to the control group (P less than 0.05); levels of CRP, IL-6 and IL-8 were in positive correlation to the SOFA scores and in negative correlation to PCIS. Analysis of receiver operating characteristics (ROC) curve demonstrated that the sensitivity, specificity and accuracy were 85.7%, 80.2% and 81.8%, respectively, when IL-6 level was set as 32 pg/mL, 78.1%, 64.2% and 66.9%, respectively when IL-8 level was set as 54 pg/mL, and 71.4%, 86.3% and 82.7% respectively, when detection of IL-6 and IL-8 were combined together. Hence it can be concluded that: IL-6 and IL-8 are involved in inflammatory reactions; levels of IL-6 and IL-8 were correlated to the severity of the infection; the value of IL-6 is higher than that of IL-8 in the diagnosis of neonatal septicemia and the combined detection of IL-6 and IL-8 can improve the accuracy of the diagnosis of neonatal septicemia.
Collapse
|
34
|
Cao JG, Wang L, Zhao HW, Liu J. Semitendinosus and gracilis transfer for treatment of medial collateral ligament injury of total knee arthroplasty. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2016; 20:3738-3742. [PMID: 27735047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
OBJECTIVE The objective of the study is to evaluate the clinic effectiveness of semitendinosus and gracilis transfer for the treatment of medial collateral ligament (MCL) injury of total knee arthroplasty (TKA). PATIENTS AND METHODS From March 2009 to May 2014, a series of 11 patients with MCL injuries of primary TKA were treated by semitendinosus and gracilis transfer. Another 18 patients (21 knees) were recruited as control group. The two groups of patients were comparable for gender, age, body mass index, varus knee deformity, KSS score, joint activity degree and type of prosthesis comparison without significant difference (p > 0.05). All the patients were regularly followed-up using the American Knee Society Scoring System (KSS). RESULTS No patient of either group reported impaired wound healing, joint instability, pain, prosthesis loosening and other complications. At the final follow-up, the mean knee objective score and the functional score of the injury group include (89.82 ± 3.76) points and (89.54 ± 3.50) points, respectively. The control group includes (90.19 ± 3.39) and (90 ± 3.53) points. They were significantly higher than the preoperative conditions. The difference was not statistically significant. The difference of KSS score was not statistically significant (t = 0.158, p = 0.877; t = 0.820, p = 0.432). CONCLUSIONS The semitendinosus and gracilis transfer are reliable for the treatment of MCL injury of TKA. The semitendinosus and gracilis are close to the knee MCL, which can effectively improve knee function.
Collapse
|
35
|
Ma YC, Su N, Zhao NM, Li QY, Zhang M, Zhao HW, Liu HM, Qin YH. [Jaridonin, a new diterpenoid from Isodon rubescens, induces cell cycle arrest in gastric cancer cells through activating ataxia telangiectasia mutated kinase]. ZHONGHUA ZHONG LIU ZA ZHI [CHINESE JOURNAL OF ONCOLOGY] 2016; 38:258-62. [PMID: 27087371 DOI: 10.3760/cma.j.issn.0253-3766.2016.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE To study the effects of Jaridonin, a novel diterpenoid from isodon rubescens, on the cell cycle of human gastric cancer cells and its molecular mechanism of action. METHODS Flow cytometry was used to analyze the cell cycle distribution and expression of ataxia telangiectasia mutated kinase (ATM) after Jaridonin treatment. Western blot was performed to detect the expression of cell cycle-related proteins. RESULTS The results of flow cytometry showed that the percentages of MGC-803 cells in G(2)/M phase at 6 hours after 0, 10, 20 μmol/L Jaridonin-treatment were (10.8±2.2)%, (18.2±2.5)%, (27.3±3.2)%, respectively; those at 12 hours after Jaridonin-treatment were (12.0±1.5)%, (24.1±2.0)% and (39.7±5.2)%, respectively, indicating a G2/M phase arrest of MGC-803 cells was resulted in a time- and dose-dependent manner. The expressions of ATM, Chk1, Chk2, phosphorylated Cdc2 and CDK2 were up-regulated in the MGC-803 cells after Jaridonin treatment, while the levels of Cdc2 and CDK2 were decreased. KU-55933, an inhibitor of ATM, reversed the expression of relevant proteins and G(2)/M phase arrest induced by Jaridonin. CONCLUSIONS Jaridonin can significantly induce G(2)/M arrest in gastric cancer MGC-803 cells. Its mechanism may be related to the activation of ATM and Chk1/2, and inactivation of Cdc2 and CDK2 phosphorylation.
Collapse
|
36
|
Sun L, Guo JW, Lu W, Zhang WH, Feng YC, Yang Y, Qian C, Fang X, Ma HY, Zhang XZ, Zhao HW. Advancement of highly charged ion beam production by superconducting ECR ion source SECRAL (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A707. [PMID: 26931925 DOI: 10.1063/1.4933123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
At Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), the superconducting Electron Cyclotron Resonance (ECR) ion source SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) has been put into operation for about 10 years now. It has been the main working horse to deliver intense highly charged heavy ion beams for the accelerators. Since its first plasma at 18 GHz, R&D work towards more intense highly charged ion beam production as well as the beam quality investigation has never been stopped. When SECRAL was upgraded to its typical operation frequency 24 GHz, it had already showed its promising capacity of very intense highly charged ion beam production. And it has also provided the strong experimental support for the so called scaling laws of microwave frequency effect. However, compared to the microwave power heating efficiency at 18 GHz, 24 GHz microwave heating does not show the ω(2) scale at the same power level, which indicates that microwave power coupling at gyrotron frequency needs better understanding. In this paper, after a review of the operation status of SECRAL with regard to the beam availability and stability, the recent study of the extracted ion beam transverse coupling issues will be discussed, and the test results of the both TE01 and HE11 modes will be presented. A general comparison of the performance working with the two injection modes will be given, and a preliminary analysis will be introduced. The latest results of the production of very intense highly charged ion beams, such as 1.42 emA Ar(12+), 0.92 emA Xe(27+), and so on, will be presented.
Collapse
|
37
|
Wu Q, Ma HY, Yang Y, Sun LT, Zhang XZ, Zhang ZM, Zhao HY, He Y, Zhao HW. Status of intense permanent magnet proton source for China-accelerator driven sub-critical system Linac. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B903. [PMID: 26932075 DOI: 10.1063/1.4932314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Two compact intense 2.45 GHz permanent magnet proton sources and their corresponding low energy beam transport (LEBT) system were developed successfully for China accelerator driven sub-critical system in 2014. Both the proton sources operate at 35 kV potential. The beams extracted from the ion source are transported by the LEBT, which is composed of two identical solenoids, to the 2.1 MeV Radio-Frequency Quadrupole (RFQ). In order to ensure the safety of the superconducting cavities during commissioning, an electrostatic-chopper has been designed and installed in the LEBT line that can chop the continuous wave beam into a pulsed one. The minimum width of the pulse is less than 10 μs and the fall/rise time of the chopper is about 20 ns. The performance of the proton source and the LEBT, such as beam current, beam profile, emittance and the impact to RFQ injection will be presented.
Collapse
|
38
|
Lu W, Qian C, Sun LT, Zhang XZ, Fang X, Guo JW, Yang Y, Feng YC, Ma BH, Xiong B, Ruan L, Zhao HW, Zhan WL, Xie D. High intensity high charge state ion beam production with an evaporative cooling magnet ECRIS. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A738. [PMID: 26931956 DOI: 10.1063/1.4936183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
LECR4 (Lanzhou ECR ion source No. 4) is a room temperature electron cyclotron resonance ion source, designed to produce high current, high charge state ion beams for the SSC-LINAC injector (a new injector for sector separated cyclotron) at the Institute of Modern Physics. LECR4 also serves as a PoP machine for the application of evaporative cooling technology in accelerator field. To achieve those goals, LECR4 ECR ion source has been optimized for the operation at 18 GHz. During 2014, LECR4 ion source was commissioned at 18 GHz microwave of 1.6 kW. To further study the influence of injection stage to the production of medium and high charge state ion beams, in March 2015, the injection stage with pumping system was installed, and some optimum results were produced, such as 560 eμA of O(7+), 620 eμA of Ar(11+), 430 eμA of Ar(12+), 430 eμA of Xe(20+), and so on. The comparison will be discussed in the paper.
Collapse
|
39
|
Zhao HY, Zhang JJ, Jin QY, Liu W, Wang GC, Sun LT, Zhang XZ, Zhao HW. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A917. [PMID: 26931978 DOI: 10.1063/1.4937115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10(13) W cm(-2) in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.
Collapse
|
40
|
Guo JW, Sun L, Niu XJ, Zhang XZ, Lu W, Zhang WH, Feng YC, Zhao HW. 24 GHz microwave mode converter optimized for superconducting ECR ion source SECRAL. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A708. [PMID: 26931926 DOI: 10.1063/1.4933023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Over-sized round waveguide with a diameter about Ø33.0 mm excited in the TE01 mode has been widely adopted for microwave transmission and coupling to the ECR (Electron Cyclotron Resonance) plasma with the superconducting ECR ion sources operating at 24 or 28 GHz, such as SECRAL and VENUS. In order to study the impact of different microwave modes on ECRH (Electron Cyclotron Resonance Heating) efficiency and especially the production of highly charged ions, a set of compact and efficient TE01-HE11 mode conversion and coupling system applicable to 24 GHz SECRAL whose overall length is 330 mm has been designed, fabricated and tested. Good agreements between off-line tests and calculation results have been achieved, which indicates the TE01-HE11 converter meets the application design. The detailed results of the optimized coupling system will be presented in the paper.
Collapse
|
41
|
Yang Y, Dou WP, Sun LT, Yao QG, Zhang ZM, Yuan YJ, He Y, Zh XZ, Zhao HW. Simulation study of LEBT for transversely coupled beam from an ECR ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B910. [PMID: 26932082 DOI: 10.1063/1.4933080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A Low-Energy intense-highly charged ion Accelerator Facility (LEAF) program has been launched at Institute of Modern Physics. This accelerator facility consists of a superconducting Electron Cyclotron Resonance (ECR) ion source, a Low Energy Beam Transport (LEBT) system, and a Radio Frequency Quadrupole (RFQ). It is especially of interest for the extracted ion beam from the ECR ion source, which is transversely coupled, and this property will significantly affect the beam transmission in the LEBT line and the matching with the downstream RFQ. In the beam transport design of LEAF, beam decoupling in the LEBT is considered to lower down the projection emittances and the feasibility of the design has been verified by beam simulation with a transversely coupled beam from the ECR ion source.
Collapse
|
42
|
Zhao SJ, Zhao HW, Du S, Qin YH. The Impact of Clinical Pharmacist Support on Patients Receiving Multi-drug Therapy for Coronary Heart Disease in China. Indian J Pharm Sci 2015; 77:306-11. [PMID: 26180276 PMCID: PMC4502145 DOI: 10.4103/0250-474x.159632] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2014] [Revised: 01/08/2015] [Accepted: 05/27/2015] [Indexed: 12/12/2022] Open
Abstract
The study determined pharmacist support on patients receiving multi-drug therapy for coronary heart disease by evaluating patient self-care ability, quality of life, and drug therapy compliance. In this study, ninety patients were randomly assigned to an experimental group (n=45) and a control group (n=45). The control group received conventional clinical care. The experimental group received clinical care plus pharmacist support that included medication review, patient education, lifestyle management, discharge guidance, and telephone follow-up. Eighty-five patients completed the study. Self-care ability and quality of life were evaluated before hospital discharge. The experimental group understood their condition better than the control group (P<0.05), the differences between the groups in understanding treatment goals, drug regimens, lifestyle modifications, psychogenic disorders, and satisfaction evaluations were more pronounced (P<0.01). At six-month follow-up, the difference between the groups in drug therapy compliance was P<0.01, as was success rate by intention-to-treat (77.8% vs. 48.9%) and per-protocol (81.4% vs. 52.4%). Two adverse drug reactions occurred in the experimental group and three in the control group. Pharmacist support improved self-care ability, quality of life, drug therapy compliance, and treatment success rate in coronary heart disease patients.
Collapse
|
43
|
Lu W, Sun LT, Qian C, Guo JW, Fang X, Feng YC, Yang Y, Ma HY, Zhang XZ, Ma BH, Xiong B, Guo SQ, Ruan L, Zhao HW. The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:043301. [PMID: 25933849 DOI: 10.1063/1.4916658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months' commissioning, some outstanding results have been achieved, such as 1.97 emA of O(6+), 1.7 emA of Ar(8+), 1.07 emA of Ar(9+), and 118 euA of Bi(28+). The source has also successfully delivered O(5+) and Ar(8+) ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.
Collapse
|
44
|
Zhao HW, Gu XQ, Chailangkarn T, Perkins G, Callacondo D, Appenzeller O, Poulsen O, Zhou D, Muotri AR, Haddad GG. Altered iPSC-derived neurons' sodium channel properties in subjects with Monge's disease. Neuroscience 2015; 288:187-99. [PMID: 25559931 DOI: 10.1016/j.neuroscience.2014.12.039] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 12/22/2014] [Accepted: 12/23/2014] [Indexed: 12/17/2022]
Abstract
Monge's disease, also known as chronic mountain sickness (CMS), is a disease that potentially threatens more than 140 million highlanders during extended time living at high altitudes (over 2500m). The prevalence of CMS in Andeans is about 15-20%, suggesting that the majority of highlanders (non-CMS) are rather healthy at high altitudes; however, CMS subjects experience severe hypoxemia, erythrocytosis and many neurologic manifestations including migraine, headache, mental fatigue, confusion, and memory loss. The underlying mechanisms of CMS neuropathology are not well understood and no ideal treatment is available to prevent or cure CMS, except for phlebotomy. In the current study, we reprogrammed fibroblast cells from both CMS and non-CMS subjects' skin biopsies into the induced pluripotent stem cells (iPSCs), then differentiated into neurons and compared their neuronal properties. We discovered that CMS neurons were much less excitable (higher rheobase) than non-CMS neurons. This decreased excitability was not caused by differences in passive neuronal properties, but instead by a significantly lowered Na(+) channel current density and by a shift of the voltage-conductance curve in the depolarization direction. Our findings provide, for the first time, evidence of a neuronal abnormality in CMS subjects as compared to non-CMS subjects, hoping that such studies can pave the way to a better understanding of the neuropathology in CMS.
Collapse
|
45
|
Yang Y, Yuan YJ, Sun LT, Feng YC, Fang X, Cao Y, Lu W, Zhang XZ, Zhao HW. Transverse coupling property of beam from ECR ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:113305. [PMID: 25430108 DOI: 10.1063/1.4901591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Experimental evidence of the property of transverse coupling of beam from Electron Cyclotron Resonance (ECR) ion source is presented. It is especially of interest for an ECR ion source, where the cross section of extracted beam is not round along transport path due to the magnetic confinement configuration. When the ions are extracted and accelerated through the descending axial magnetic field at the extraction region, the horizontal and vertical phase space strongly coupled. In this study, the coupling configuration between the transverse phase spaces of the beam from ECR ion source is achieved by beam back-tracking simulation based on the measurements. The reasonability of this coupling configuration has been proven by a series of subsequent simulations.
Collapse
|
46
|
Yang Y, Sun LT, Feng YC, Fang X, Lu W, Zhang WH, Cao Y, Zhang XZ, Zhao HW. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:083301. [PMID: 25173256 DOI: 10.1063/1.4891418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.
Collapse
|
47
|
Jin QY, Zhao HY, Zhang JJ, Sha S, Zhang ZL, Li ZM, Liu W, Zhang XZ, Sun LT, Zhao HW. Simulation of direct plasma injection for laser ion beam acceleration with a radio frequency quadrupole. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:073304. [PMID: 25085131 DOI: 10.1063/1.4890155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The direct plasma injection scheme (DPIS) has been being studied at Institute of Modern Physics since several years ago. A C(6+) beam with peak current of 13 mA, energy of 593 keV/u has been successfully achieved after acceleration with DPIS method. To understand the process of DPIS, some simulations have been done as follows. First, with the total current intensity and the relative yields of different charge states for carbon ions measured at the different distance from the target, the absolute current intensities and time-dependences for different charge states are scaled to the exit of the laser ion source in the DPIS. Then with these derived values as the input parameters, the extraction of carbon beam from the laser ion source to the radio frequency quadrupole with DPIS is simulated, which is well agreed with the experiment results.
Collapse
|
48
|
Wei JH, Cao JZ, Zhang D, Liao B, Zhong WM, Lu J, Zhao HW, Zhang JX, Tong ZT, Fan S, Liang CZ, Liao YB, Pang J, Wu RH, Fang Y, Chen ZH, Li B, Xie D, Chen W, Luo JH. EIF5A2 predicts outcome in localised invasive bladder cancer and promotes bladder cancer cell aggressiveness in vitro and in vivo. Br J Cancer 2014; 110:1767-77. [PMID: 24504366 PMCID: PMC3974079 DOI: 10.1038/bjc.2014.52] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2013] [Revised: 11/19/2013] [Accepted: 01/10/2014] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND EIF5A2, eukaryotic translation initiation factor 5A2, is associated with several human cancers. In this study, we investigated the role of EIF5A2 in the metastatic potential of localised invasive bladder cancer (BC) and its underlying molecular mechanisms were explored. METHODS The expression pattern of EIF5A2 in localised invasive BC was determined by immunohistochemistry. In addition, the function of EIF5A2 in BC and its underlying mechanisms were elucidated with a series of in vitro and in vivo assays. RESULTS Overexpression of EIF5A2 was an independent predictor for poor metastasis-free survival of localised invasive BC patients treated with radical cystectomy. Knockdown of EIF5A2 inhibited BC cell migratory and invasive capacities in vitro and metastatic potential in vivo and reversed epithelial-mesenchymal transition (EMT), whereas overexpression of EIF5A2 promoted BC cells motility and invasiveness in vitro and metastatic potential in vivo and induced EMT. In addition, we found that EIF5A2 might activate TGF-β1 expression to induce EMT and drive aggressiveness in BC cells. EIF5A2 stabilized STAT3 and stimulated nuclear localisation of STAT3, which resulted in increasing enrichment of STAT3 onto TGF-β1 promoter to enhance the transcription of TGF-β1. CONCLUSIONS EIF5A2 overexpression predicts tumour metastatic potential in patients with localised invasive BC treated with radical cystectomy. Furthermore, EIF5A2 elevated TGF-β1 expression through STAT3 to induce EMT and promotes aggressiveness in BC.
Collapse
|
49
|
Jin QY, Zhao HY, Sha S, Zhang JJ, Li ZM, Liu W, Zhang XZ, Sun LT, Zhao HW. Study on space charge effect in an electrostatic ion analyzer applied to measure laser produced ions. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:033307. [PMID: 24689575 DOI: 10.1063/1.4869015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The abundance of different ions produced by laser ion sources is usually analyzed by an electrostatic ion analyzer (EIA). Ion current intensities in the range of several mA/cm(2) at the position of the EIA have been achieved from the laser ion source developed by the Institute of Modern Physics; this indicates that a noticeable influence of space charge effect during the ion transmission will occur. Hence, while the parameters of the EIA or the beams are changed, such as ion species, current intensity, the ions' transmission efficiency through the EIA is different, which will result in an uncertainty in the estimation of the ions' yields. Special attention is focused on this issue in this paper. Ion's transmissions through the EIA under different circumstances are studied with simulations and experiments, the results of which are consistent with each other.
Collapse
|
50
|
Zhao HY, Jin QY, Sha S, Zhang JJ, Li ZM, Liu W, Sun LT, Zhang XZ, Zhao HW. The study towards high intensity high charge state laser ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B910. [PMID: 24593615 DOI: 10.1063/1.4833921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.
Collapse
|