26
|
Fallon JK, Shah D, Kicman AT, Hutt AJ, Henry JA, Cowan DA, Forsling M. Action of MDMA (ecstasy) and its metabolites on arginine vasopressin release. Ann N Y Acad Sci 2002; 965:399-409. [PMID: 12105115 DOI: 10.1111/j.1749-6632.2002.tb04181.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
3,4-Methylenedioxymethamphetamine (MDMA) has been reported to cause hyponatraemia, which appears to result from inappropriate secretion of the antidiuretic hormone arginine vasopressin (AVP). After administration of a low dose of (R,S)-MDMA (40 mg) to eight healthy drug-free male volunteers, concentrations of AVP in plasma increased significantly at 1, 2, and 4 hours. Although no relation between plasma MDMA and AVP was found on an examination of the entire data set over the 24-hour study period, a statistically significant negative correlation was observed at 1 hour. As this occurred at a time when both AVP and MDMA concentrations were rising, it was postulated that a metabolite, or metabolites, could primarily be responsible for the increase in AVP. To test this hypothesis we examined the effect of MDMA and five of its metabolites, in the dose range 0.1-1,000 nM, on AVP release from the isolated rat hypothalamus. All compounds tested were found to increase AVP release (using 10 nM and 1,000 nM concentrations), with 4-hydroxy-3-methoxymethamphetamine (HMMA), the major metabolite of MDMA, being the most potent, and 3,4-dihydroxymethamphetamine (DHMA) the least potent. Each compound (1,000 nM), with the exception of DHMA, also enhanced the response to 40-mM potassium stimulation. Our findings confirm that metabolites of MDMA, in addition to the parent drug, contribute to AVP secretion in vitro. Further work will demonstrate whether this is also true in vivo.
Collapse
|
27
|
|
28
|
Darcy P, Kelly JP, Leonard BE, Henry JA. The effect of lofepramine and other related agents on the motility of Tetrahymena pyriformis. Toxicol Lett 2002; 128:207-14. [PMID: 11869831 DOI: 10.1016/s0378-4274(01)00542-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Tricyclic antidepressants (TCAs) were introduced almost 50 years ago. Whilst there is no doubt that TCAs are effective in treating depression, they are also more cardiotoxic when taken in overdose than other antidepressant groups. Lofepramine is a more recently introduced modified TCA, which in animals and man has low toxicity when compared to older TCAs. Paradoxically, lofepramine is extensively metabolised to desipramine, which has considerable toxicity, both experimentally and in overdose. The toxicity of such compounds is attributed, in part, to a membrane stabilising effect (MSA) on cell membranes. This MSA causes gross effects to the cell structure and in turn, normal cell activity. The aim of this study was to compare the MSA of lofepramine with that of desipramine and amitriptyline in order to see if this might help to explain the low toxicity of lofepramine. The local anaesthetic agent lignocaine was also studied for comparison. Each compound was enclosed in a beta-cyclodextrin to increase its solubility in aqueous medium. The extent of MSA was determined as a measure of the effect on the swimming speed of the protozoan Tetrahymena pyriformis using a video image analysis system. The IC50s for the various drugs were then correlated with their respective octanol-water partition coefficient values (Pow). Amitriptyline had an IC50 of 1.26+/-0.29 mM, desipramine 75.99+/-14.40 mM, while lofepramine had an IC50 of 357.40+/-25.00 mM. Lignocaine had an IC50 of 85.73+/-18.30 mM. There was also a significant correlation between the IC50 values and the Pow values.
Collapse
|
29
|
Ma Y, Henry JA. The antidotal effect of alpha(1)-acid glycoprotein on amitriptyline toxicity in cardiac myocytes. Toxicology 2001; 169:133-44. [PMID: 11718954 DOI: 10.1016/s0300-483x(01)00495-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Tricyclic antidepressants in overdose cause toxicity marked by prolongation of the QRS interval of the electrocardiogram. These drugs are bound to alpha(1)-acid glycoprotein (AAG) with high affinity in plasma. Animal studies have shown that the administration of AAG shortens the QRS prolongation induced by tricyclic antidepressants. In order to clarify the pharmacological mechanism involved and to obtain clinically relevant evidence at the cellular level, whole-cell patch clamp techniques were performed in single guinea-pig ventricular myocytes to elicit the time and voltage-dependent fast sodium currents using both normal and modified physiological solutions. Cells stayed viable for much longer when they were placed in normal physiological solutions, providing sufficient recording time for consistently reproducible, clinically relevant toxicological results to be obtained. Amitriptyline (AMI) produced a concentration-dependent blockade of sodium currents with an approximate IC(50) of 0.69 microM. AAG reversed this blockade in a concentration-dependent fashion at concentrations ranging from 3.2 to 12.8 microM. Using the same experimental conditions, AAG also reversed the blockade of sodium current by quinidine, a class I antiarrythmic drug. Albumin did not reverse the blockade of sodium channels by AMI. The results indicate that AAG is a potential antidote for tricyclic antidepressant overdose.
Collapse
|
30
|
Abstract
Petroleum products are highly complex chemical mixtures consisting predominantly of hydrocarbons. Their composition varies with source and intended use of the product. Virtually all are blended products that come into contact with man in a wide range of circumstances. Their toxicity for man is generally low and the use of additives rarely affects the toxicity of the final product. Because products are blended to meet performance, and not chemical specifications, their composition varies significantly. Management of toxicity benefits from simplified guidelines that consider the product by its type. Management in most cases is symptomatic, but the doctor needs to be aware of the potential for development of sequelae such as aspiration pneumonia and central nervous system (CNS) depression. Local and systemic effects of exposure to hydrocarbons are reviewed, as are immediate assessment and recommended management of acute exposure to petroleum products. Because of the large scope of this subject, this paper limits itself to acute toxicity of petroleum products encountered inthe public domain. It does not address topics such as chronic toxicity, solvent abuse, petrochemicals, or pesticides.
Collapse
|
31
|
Forsling M, Fallon JK, Kicman AT, Hutt AJ, Cowan DA, Henry JA. Arginine vasopressin release in response to the administration of 3,4-methylenedioxymethamphetamine ("ecstasy"): is metabolism a contributory factor? J Pharm Pharmacol 2001; 53:1357-63. [PMID: 11697543 DOI: 10.1211/0022357011777855] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
The aim of this investigation was to examine the effect of 3,4-methylenedioxymethamphetamine (MDMA) administration on arginine vasopressin (AVP) release. (R,S)-MDMA (40 mg) was administered to eight normally hydrated healthy male volunteers (22-32 years) and blood samples were collected up to 24 h. Plasma was assayed for AVP and cortisol by radioimmunoassays, and for MDMA and the N-demethylated metabolite, MDA, by gas chromatography-mass spectrometry. Sodium concentrations and osmolality were also determined. Plasma AVP increased in all subjects after MDMA administration and a significant negative correlation was observed between concentrations of AVP and both single and total enantiomer MDMA at 1 h (r < -0.91, P < 0.01). This had disappeared by 2 h (P > 0.7). Compared with basal values, no significant change was observed for osmolality or cortisol at 1 h after drug administration. In conclusion, plasma AVP concentrations increase after MDMA administration, but the increase is not part of a generalized stress response since cortisol did not increase concurrently. A significant negative correlation between plasma MDMA and AVP was observed soon after administration. The possibility that a pharmacological effect of MDMA is primarily mediated via one or more metabolites, rather than by the parent drug, should be considered.
Collapse
|
32
|
Henry JA, Flick CL, Gilbert A, Ellingson RM, Fausti SA. Comparison of two computer-automated procedures for tinnitus pitch matching. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2001; 38:557-66. [PMID: 11732833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Clinical assessment of the perceptual characteristics of tinnitus usually includes an attempt to match the pitch of tinnitus to a pure tone. A standardized clinical protocol for tinnitus pitch matching does not yet exist, and there is a history of unsuccessful attempts to obtain such measures reliably. The present study was designed to evaluate new protocols for identifying the perceived pitch of tinnitus, with the objectives of reducing testing time and improving test-retest reliability. Two protocols ("Octave" and "Binary") were developed, each of which was patterned after the testing procedure previously developed at the Oregon Tinnitus Clinic and used to assess thousands of tinnitus patients. Both protocols use computer-automation to conduct testing; the protocols differ according to their specific testing algorithms. Twenty subjects with nonfluctuating tinnitus were each tested over two sessions. Results of testing revealed that both protocols could obtain pitch matches within 20 to 25 min. Reliability of responses was good for some subjects but not others, and the Binary protocol generally provided more reliable results.
Collapse
|
33
|
Henry JA, Flick CL, Gilbert A, Ellingson RM, Fausti SA. Reliability of hearing thresholds: computer-automated testing with ER-4B Canal Phone earphones. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2001; 38:567-81. [PMID: 11732834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
This study was conducted to document test-retest reliability of hearing thresholds using our computer-automated tinnitus matching technique and Etymotic ER-4B Canal Phone insert earphones. The research design involved repeated threshold measurements both within and between sessions, and testing to evaluate the potential effect of eartip removal and reinsertion. Twenty normal-hearing subjects were evaluated over two testing sessions with the use of a fully automated protocol for determining thresholds with 1-dB precision. Thresholds were first obtained at 0.5-16.0 kHz, in one-third octave frequency steps (16 test frequencies). The octave frequencies were then retested, first without removing the eartips, then after eartip removal and replacement. Responses between sessions differed by an average of 2.5 dB across all 16 test frequencies, and 91.5 percent of the repeated thresholds varied within +/-5 dB (98.1 percent within +/-10 dB). Reliability of within-sessions thresholds was also good, and there was no effect of eartip removal and replacement.
Collapse
|
34
|
Garbino J, Henry JA, Mentha G, Romand JA. Ecstasy ingestion and fulminant hepatic failure: liver transplantation to be considered as a last therapeutic option. VETERINARY AND HUMAN TOXICOLOGY 2001; 43:99-102. [PMID: 11308131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Severe adverse effects due to 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) are reported with increasing frequency in the medical literature. The signs of acute toxicity most often seen are fulminant hyperthermia, hyperexcitatory states, acute renal failure and hyponatraemia. In 1992, hepatotoxicity was also described with unexplained jaundice and hepatomegaly after ingestion of MDMA. We report a case of severe toxic hepatitis following ingestion of MDMA with fulminant hepatic failure which required auxiliary liver transplantation. The diagnosis was necrotic toxic hepatitis following ecstasy ingestion. The outcome was successful, and the patient was discharged from ICU 20 d after surgery. Hepatotoxic effects of MDMA seem infrequent, but may be lethal; liver transplantation is the ultimate therapeutic option in some cases.
Collapse
|
35
|
Doolittle ND, Muldoon LL, Brummett RE, Tyson RM, Lacy C, Bubalo JS, Kraemer DF, Heinrich MC, Henry JA, Neuwelt EA. Delayed sodium thiosulfate as an otoprotectant against carboplatin-induced hearing loss in patients with malignant brain tumors. Clin Cancer Res 2001; 7:493-500. [PMID: 11297239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Carboplatin is effective in the treatment of malignant brain tumors. However, when administered in conjunction with osmotic opening of the blood-brain barrier (BBB), carboplatin is ototoxic. The purpose of this study was to determine whether delayed administration of sodium thiosulfate (STS), given after BBB closure, provided protection against carboplatin ototoxicity. Patients underwent monthly treatment with intra-arterial carboplatin (200 mg/m2/day x 2) in conjunction with osmotic opening of the BBB, for up to 1 year. Audiological assessment was conducted at baseline and within 24 h before each monthly treatment. STS was administered i.v. as one (20 g/m2) or two (20 g/m2 and 16 g/m2) 15-min doses, depending on baseline hearing status. The initial group received the first STS dose 2 h (or 2 and 6 h) after carboplatin (STS2) and a subsequent group received STS 4 h (or 4 and 8 h) after carboplatin (STS4). Audiological data were compared with a historical comparison group (HCG) treated with carboplatin without STS. Spearman correlation coefficients comparing STS 2 (n = 24), STS4 (n = 17), and HCG (n = 19) indicated significantly lower rates of ototoxicity with increased delay in STS (P = 0.0006). On the basis of the analysis of hearing levels, there were significant differences among the two STS groups and HCG at 8000 Hz (P = 0.0010) and at 4000 Hz (P = 0.0075). The log-rank test for time to ototoxicity indicated a significant difference between STS4 and HCG (P = 0.0018). Delayed STS was effective in protecting against carboplatin-induced hearing loss. STS delayed to 4 h after carboplatin significantly decreased time to development of ototoxicity and rate of ototoxicity when compared with HCG.
Collapse
|
36
|
Middleton PM, Retter A, Henry JA. Pulse oximeter waveform analysis as a measure of circulatory status. Crit Care 2001. [PMCID: PMC3333339 DOI: 10.1186/cc1219] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
37
|
Middleton PM, Henry JA. Pulse oximetry: evolution and directions. Int J Clin Pract 2000; 54:438-44. [PMID: 11070568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/18/2023] Open
Abstract
Pulse oximetry monitoring is a relatively recent technique that has been embraced enthusiastically by medical, nursing and paramedical personnel in many clinical situations. Few people, however, have any idea of how it provides the reading of arterial blood saturation. This review performs several functions: it discusses the haemoglobin molecular structure and explains its relation to spectrophotometry, describes the history and principles of pulse oximetry and the nature of the equipment used, and reviews its common uses. It also explores the principles and proposed uses of its lesser known corollary, photoplethysmography.
Collapse
|
38
|
|
39
|
Henry JA, Fausti SA, Flick CL, Helt WJ, Ellingson RM. Computer-automated clinical technique for tinnitus quantification. Am J Audiol 2000; 9:36-49. [PMID: 10943023 DOI: 10.1044/1059-0889(2000/002)] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
This study addresses the need for uniformity in techniques for clinical quantification of tinnitus. Because automation can be an effective means to achieve standardization, this laboratory is developing techniques to perform computer-automated tinnitus testing. The present study was conducted to demonstrate the feasibility of obtaining reliable tinnitus measures using a fully automated system. A computer-controlled psychoacoustical system was developed to quantify tinnitus loudness and pitch using a tone-matching technique. Hearing thresholds were also obtained as part of the procedure. The system generated test stimuli and simultaneously controlled a notebook computer positioned in the sound chamber facing the patient. The notebook computer displayed instructions for responding and relayed response choices through on-screen "buttons" that the patient touched with a pen device. Twenty individuals with tinnitus were evaluated with the technique over two sessions, and responses were analyzed for test-retest reliability. Analyses revealed good reliability of thresholds, loudness matches, and pitch matches. These results demonstrate that use of a fully automated system to obtain reliable measurements of tinnitus loudness and pitch is feasible for clinical application.
Collapse
|
40
|
Henry JA, Meikle MB. Psychoacoustic measures of tinnitus. J Am Acad Audiol 2000; 11:138-55. [PMID: 10755810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
This report reviews research from the 1930s to the present that has extended our understanding by investigating the characteristics of tinnitus that can be studied using psychoacoustic techniques. Studies of tinnitus masking and residual inhibition began in the 1970s, leading to the therapeutic use of tinnitus masking and a consequent increase in research devoted to tinnitus measurement. In 1981, the CIBA Foundation symposium on tinnitus advocated general adoption of four tinnitus measures: (1) pitch, (2) loudness, (3) maskability, and (4) residual inhibition. Since then, psychoacoustic research into all four topics has proliferated, yielding many valuable insights and controversies concerning the details of measurement techniques. A consensus has emerged that neither the loudness nor other psychoacoustic measures of tinnitus bear a consistent relation to the severity or perceived loudness of tinnitus. Nevertheless, quantification is needed in clinical trials of proposed treatments and in a variety of other types of tinnitus research. Standardization of techniques for specifying the acoustic parameters of tinnitus thus continues to be an important research goal.
Collapse
|
41
|
Abstract
Substance abuse has been increasing steadily in the UK and some other countries. Recent evidence suggests more than 40% of young people have tried illicit drugs at some time. There are numerous medical consequences to recreational drug use, and a physician should always consider substance abuse in any unexplained illness. The renal complications of drug abuse are also becoming more frequent, and may encompass a spectrum of glomerular, interstitial and vascular diseases. Although some substances are directly nephrotoxic, a number of other mechanisms are also involved. These effects are often chronic and irreversible, but occasionally acute with possible recovery. The rapid growth of illicit drug use is clearly a major public health problem. We review the commonly used substances of abuse and their associations with renal disease.
Collapse
|
42
|
Henry JA, Fausti SA, Kempton JB, Trune DR, Mitchell CR. Twenty-stimulus train for rapid acquisition of auditory brainstem responses in humans. J Am Acad Audiol 2000; 11:103-13. [PMID: 10685677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
This study addressed the clinical need to obtain frequency-specific auditory brainstem responses (ABRs) more rapidly than is currently possible. ABRs were obtained from 20 subjects using two different methods: a conventional method with tone bursts presented singly and a multiple-stimulus method using a train of 20 tone bursts. For both methods, tone bursts were presented at frequencies 1, 2, 4, and 8 kHz, shaped with a Blackman-Harris window and having intensity levels up to 105 dB peak equivalent sound pressure level (peSPL). The single tone bursts were presented at a 17.2/sec repetition rate. The 20 tone-burst train used the four frequencies at five intensities each and a repetition rate of 3.7/sec (separations between tone bursts of 9-12 msec, with 77 msec off-time between trains). Mean latencies and mean amplitudes for wave V were compared using t-tests for each of 12 conditions (four frequencies, each at the three highest output levels). For latency, only one comparison was significantly different (2 kHz, 77 dB peSPL). Similarly, only one comparison was significant for amplitude (2 kHz, 97 dB peSPL). There was, however, a trend for the tone bursts presented in trains to have longer latencies and reduced amplitudes compared to the respective responses for the single tone-burst condition. These results indicate the presence of some response adaptation when tone bursts are presented in a train. The use of a properly designed stimulus train can result in a significant time savings for obtaining frequency-specific ABRs as compared with single tone-burst presentations.
Collapse
|
43
|
Elliott P, Arnold R, Barltrop D, Thornton I, House IM, Henry JA. Clinical lead poisoning in England: an analysis of routine sources of data. Occup Environ Med 1999; 56:820-4. [PMID: 10658538 PMCID: PMC1757691 DOI: 10.1136/oem.56.12.820] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To examine the occurrence of clinical lead poisoning in England based on routine sources of data. METHODS Three routine data sources were examined, over different periods according to availability of data: (a) mortality for England, 1981-96; (b) hospital episode statistics data for England, for the 3 years 1 April 1992-31 March 1995; (c) statutory returns to the Health and Safety Executive under the reporting of injuries, diseases, and dangerous occurrences regulations (RIDDOR), also for the period 1 April 1992-31 March 1995. Also, analyses of blood lead concentrations carried out by the Medical Toxicology Unit, Guy's and St Thomas' Hospital Trust in London during the period 1 January 1991-31 December 1997 were examined. The analyses were performed both for industrial screening purposes and in response to clinicians' requests where lead poisoning was suspected. This is one of several laboratories carrying out such analyses in the United Kingdom. RESULTS One death, of a 2 year old girl, was coded to lead poisoning in England during 1981-96. Analysis of hospital episode statistics data identified 83 hospital cases (124 admissions) over 3 years with any mention of lead poisoning, excluding two with admissions dating from 1965 and 1969. For these 83 cases the median hospital stay per admission was 3 days (range 0-115 days). Five were coded as having received intravenous treatment. Further clinical details of these cases beyond what is routinely recorded on the hospital episode statistics database were not available, except for blood lead concentrations in cases also identified on the Medical Toxicology Unit database. Eighteen cases (22%) were below 5 years of age of whom 10 (56%) came from the most deprived quintile of electoral wards. There was evidence to suggest spatial clustering of cases (p = 0.02). Six occupational cases were reported under RIDDOR in England during the period of study, two of whom were identified on the hospital episode statistics database. One further occupational case was identified on hospital episode statistics. Blood lead analyses for 4424 people carried out by the Medical Toxicology Unit (estimated at about 5% of such analyses in England over 7 years) found that among 547 children aged 0-4, 45 (8.2%) had a blood lead concentration in excess of 25 micrograms/dl, the action level in the United Kingdom for investigation, or removal of environmental sources of lead. At all ages, there were 419 (9.5%) such people, including 106 adults with no mention of industrial exposure. CONCLUSIONS Both mortality and hospital admission ascribed to lead poisoning in England are rare, but cases continue to occur and some, at least, seem to be associated with considerable morbidity. Lead poisoning was confirmed as a probable cause of clinical signs and symptoms in only a small proportion of those in whom a blood lead concentration was requested. Where indicated, appropriate remedial action for the safe removal of environmental sources of lead should be taken.
Collapse
|
44
|
Fausti SA, Henry JA, Helt WJ, Phillips DS, Frey RH, Noffsinger D, Larson VD, Fowler CG. An individualized, sensitive frequency range for early detection of ototoxicity. Ear Hear 1999; 20:497-505. [PMID: 10613387 DOI: 10.1097/00003446-199912000-00005] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to identify auditory frequencies at which serial threshold testing would provide the greatest sensitivity for early detection of ototoxicity. The overall objective is to develop a more time-efficient ototoxicity monitoring protocol. DESIGN Threshold data were analyzed from 370 hospitalized patients treated with aminoglycoside antibiotics (AMGs) or cisplatin (CDDP) who received serial auditory monitoring before, during, and after treatment at conventional (0.25 to 8 kHz) and high (9 to 20 kHz) frequencies. RESULTS For patients showing hearing changes due to ototoxicity, a frequency range was identified for its apparent high sensitivity to initial ototoxicity. This sensitive range is identified according to an individual's hearing threshold configuration, and is, therefore, unique for each patient. The range consists of five frequencies, generally separated by 1/6 octave, e.g., 8, 9, 10, 11.2, and 12.5 kHz. To determine frequencies and combinations of frequencies that were most often involved in ototoxicity detection, threshold data in the sensitive range were analyzed in detail. This analysis suggests that patients receiving treatment with AMG or CDDP can be monitored for hearing thresholds at only five frequencies, resulting in an 84% detection rate for AMG and 94% for CDDP compared with monitoring at all conventional and high frequencies. CONCLUSIONS This comprehensive analysis supports earlier observations that a sensitive, limited frequency range exists in which serial threshold monitoring will provide early warning of ototoxicity before effects in the speech frequency range. This finding is now being evaluated in a prospective investigation.
Collapse
|
45
|
Henry JA, Flick CL, Gilbert A, Ellingson RM, Fausti SA. Reliability of tinnitus loudness matches under procedural variation. J Am Acad Audiol 1999; 10:502-20. [PMID: 10522624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
Repeated tinnitus loudness matches (LMs) were obtained to determine response reliability using a computer-automated technique with two procedural variations, fixed or random step sizes, to increase output level during the initial ascending series of tones at each frequency. Twenty subjects with stable, tonal tinnitus were evaluated with both methods during each of two sessions. Response instructions were displayed on a portable computer, and a pen device was used to make response choices that appeared on the touch-sensitive video monitor. For each method, hearing thresholds and LMs were obtained, with 1-dB resolution, at 1/3-octave frequencies from 1 to 16 kHz. Analyses revealed reliability of LMs to be equivalent between methods. LM data are reported in both dB SPL and dB SL, with the SPL values providing greater reliability both within and between sessions (all r's > or = .889, p's < or = .0001).
Collapse
|
46
|
Henry JA. Fatal opioid toxicity--a clinical perspective. Addiction 1999; 94:974-5. [PMID: 10707432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
|
47
|
Fallon JK, Kicman AT, Henry JA, Milligan PJ, Cowan DA, Hutt AJ. Stereospecific analysis and enantiomeric disposition of 3, 4-methylenedioxymethamphetamine (Ecstasy) in humans. Clin Chem 1999; 45:1058-69. [PMID: 10388483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
BACKGROUND Little is known concerning the enantioselective disposition of 3,4-methylenedioxymethamphetamine (MDMA; ecstasy) in humans. In addition, the potential of utilizing the stereochemical composition of an analyte in biological media for forensic purposes requires investigation. METHODS The enantiomers of MDMA and its demethylated metabolite, 3,4-methylenedioxyamphetamine (MDA), present in plasma and urine extracts were derivatized with (-)-(R)-alpha-methoxy-alpha-trifluoromethylphenylacetyl chloride and analyzed by gas chromatography-mass spectrometry and gas chromatography, respectively. The enantioselective disposition of MDMA and MDA was determined following oral administration of racemic MDMA (40 mg) to eight male volunteers. RESULTS The plasma concentrations of (R)-MDMA exceeded those of the S-enantiomer [ratio R:S of the area under the curve (AUC), 2.4 +/- 0.3], and the plasma half-life of (R)-MDMA (5.8 +/- 2.2 h) was significantly longer than that of the S-enantiomer (3.6 +/- 0.9 h). The majority of the recovered material in urine was excreted within 24 h after dosing, with the recovery of (R)-MDMA (21.4% +/- 11.6%) being significantly greater than that of (S)-MDMA (9.3% +/- 4.9%), and with (S)- and (R)-MDA accounting for 1.4% +/- 0.5% and 1.0% +/- 0.3% of the dose, respectively. Mathematical modeling of plasma enantiomeric composition vs sampling time demonstrated the applicability of using stereochemical data for the prediction of time elapsed after drug administration. CONCLUSIONS Analytical methods for determining the enantiomeric composition of MDMA and MDA in plasma and urine were developed. The disposition of MDMA in humans is stereoselective, with the more active S-enantiomer having a reduced AUC and shorter half-life than (R)-MDMA. The determination of stereochemical composition may be applicable for forensic purposes.
Collapse
|
48
|
Henry JA, Meikle MB. Pulsed versus continuous tones for evaluating the loudness of tinnitus. J Am Acad Audiol 1999; 10:261-72. [PMID: 10331618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Loudness balance techniques are commonly employed to match the loudness of tinnitus using either pulsed or continuous tones; however, it is not known whether the tone duration affects the observed loudness matches. In this study, hearing thresholds and tinnitus loudness matches were measured in 26 subjects with chronic tinnitus using both pulsed and continuous tones. Subjects' thresholds and loudness matches were determined at 11 frequencies between 0.5 and 10 kHz. No significant differences were found between pulsed versus continuous measures, either for thresholds or for loudness matches. There were, however, nine subjects (34.5% of the group) who showed relatively large differences (> or =10 dB) at one or more test frequencies. These "outlier" values did not show systematic trends; some were positive, some negative. In conclusion, studies employing group data appear to be comparable if group sizes are sufficiently large (e.g., > or =25 subjects). Studies employing smaller numbers of subjects may, however, be vulnerable to potential positive or negative biases introduced by one or more outliers.
Collapse
|
49
|
Abstract
Methadone is now widely used as opioid replacement therapy because it reduces crime and prevents spread of disease by the intravenous route. However, it is potentially toxic, especially to drug naive patients, and requires careful prescribing.
Collapse
|
50
|
|