van Praagh GD, van der Werf NR, Wang J, van Ommen F, Poelhekken K, Slart RHJA, Fleischmann D, Greuter MJW, Leiner T, Willemink MJ. Fully automated quantification method (FQM) of coronary calcium in an anthropomorphic phantom. Med Phys 2021; 48:3730-3740. [PMID: 33932026 PMCID: PMC8360117 DOI: 10.1002/mp.14912] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 02/19/2021] [Accepted: 04/15/2021] [Indexed: 12/23/2022] Open
Abstract
Objective Coronary artery calcium (CAC) score is a strong predictor for future adverse cardiovascular events. Anthropomorphic phantoms are often used for CAC studies on computed tomography (CT) to allow for evaluation or variation of scanning or reconstruction parameters within or across scanners against a reference standard. This often results in large number of datasets. Manual assessment of these large datasets is time consuming and cumbersome. Therefore, this study aimed to develop and validate a fully automated, open‐source quantification method (FQM) for coronary calcium in a standardized phantom. Materials and Methods A standard, commercially available anthropomorphic thorax phantom was used with an insert containing nine calcifications with different sizes and densities. To simulate two different patient sizes, an extension ring was used. Image data were acquired with four state‐of‐the‐art CT systems using routine CAC scoring acquisition protocols. For interscan variability, each acquisition was repeated five times with small translations and/or rotations. Vendor‐specific CAC scores (Agatston, volume, and mass) were calculated as reference scores using vendor‐specific software. Both the international standard CAC quantification methods as well as vendor‐specific adjustments were implemented in FQM. Reference and FQM scores were compared using Bland‐Altman analysis, intraclass correlation coefficients, risk reclassifications, and Cohen’s kappa. Also, robustness of FQM was assessed using varied acquisitions and reconstruction settings and validation on a dynamic phantom. Further, image quality metrics were implemented: noise power spectrum, task transfer function, and contrast‐ and signal‐to‐noise ratio among others. Results were validated using imQuest software. Results Three parameters in CAC scoring methods varied among the different vendor‐specific software packages: the Hounsfield unit (HU) threshold, the minimum area used to designate a group of voxels as calcium, and the usage of isotropic voxels for the volume score. The FQM was in high agreement with vendor‐specific scores and ICC’s (median [95% CI]) were excellent (1.000 [0.999‐1.000] to 1.000 [1.000‐1.000]). An excellent interplatform reliability of κ = 0.969 and κ = 0.973 was found. TTF results gave a maximum deviation of 3.8% and NPS results were comparable to imQuest. Conclusions We developed a fully automated, open‐source, robust method to quantify CAC on CT scans in a commercially available phantom. Also, the automated algorithm contains image quality assessment for fast comparison of differences in acquisition and reconstruction parameters.
Collapse
|
27
|
Higashigaito K, Sailer AM, van Kuijk SMJ, Willemink MJ, Hahn LD, Hastie TJ, Miller DC, Fischbein MP, Fleischmann D. Aortic growth and development of partial false lumen thrombosis are associated with late adverse events in type B aortic dissection. J Thorac Cardiovasc Surg 2021; 161:1184-1190.e2. [PMID: 31839226 PMCID: PMC10552621 DOI: 10.1016/j.jtcvs.2019.10.074] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Revised: 09/13/2019] [Accepted: 10/02/2019] [Indexed: 12/27/2022]
Abstract
BACKGROUND Patients with medically treated type B aortic dissection (TBAD) remain at significant risk for late adverse events (LAEs). We hypothesize that not only initial morphological features, but also their change over time at follow-up are associated with LAEs. MATERIALS AND METHODS Baseline and 188 follow-up computed tomography (CT) scans with a median follow-up time of 4 years (range, 10 days to 12.7 years) of 47 patients with acute uncomplicated TBAD were retrospectively reviewed. Morphological features (n = 8) were quantified at baseline and each follow-up. Medical records were reviewed for LAEs, which were defined according to current guidelines. To assess the effects of changes of morphological features over time, the linear mixed effects models were combined with Cox proportional hazards regression for the time-to-event outcome using a joint modeling approach. RESULTS LAEs occurred in 21 of 47 patients at a median of 6.6 years (95% confidence interval [CI], 5.1-11.2 years). Among the 8 investigated morphological features, the following 3 features showed strong association with LAEs: increase in partial false lumen thrombosis area (hazard ratio [HR], 1.39; 95% CI, 1.18-1.66 per cm2 increase; P < .001), increase of major aortic diameter (HR, 1.24; 95% CI, 1.13-1.37 per mm increase; P < .001), and increase in the circumferential extent of false lumen (HR, 1.05; 95% CI, 1.01-1.10 per degree increase; P < .001). CONCLUSIONS In medically treated TBAD, increases in aortic diameter, new or increased partial false lumen thrombosis area, and increases of circumferential extent of the false lumen are strongly associated with LAEs.
Collapse
|
28
|
Willemink MJ, Varga-Szemes A, Schoepf UJ, Codari M, Nieman K, Fleischmann D, Mastrodicasa D. Emerging methods for the characterization of ischemic heart disease: ultrafast Doppler angiography, micro-CT, photon-counting CT, novel MRI and PET techniques, and artificial intelligence. Eur Radiol Exp 2021; 5:12. [PMID: 33763754 PMCID: PMC7991013 DOI: 10.1186/s41747-021-00207-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 01/22/2021] [Indexed: 12/24/2022] Open
Abstract
After an ischemic event, disruptive changes in the healthy myocardium may gradually develop and may ultimately turn into fibrotic scar. While these structural changes have been described by conventional imaging modalities mostly on a macroscopic scale-i.e., late gadolinium enhancement at magnetic resonance imaging (MRI)-in recent years, novel imaging methods have shown the potential to unveil an even more detailed picture of the postischemic myocardial phenomena. These new methods may bring advances in the understanding of ischemic heart disease with potential major changes in the current clinical practice. In this review article, we provide an overview of the emerging methods for the non-invasive characterization of ischemic heart disease, including coronary ultrafast Doppler angiography, photon-counting computed tomography (CT), micro-CT (for preclinical studies), low-field and ultrahigh-field MRI, and 11C-methionine positron emission tomography. In addition, we discuss new opportunities brought by artificial intelligence, while addressing promising future scenarios and the challenges for the application of artificial intelligence in the field of cardiac imaging.
Collapse
|
29
|
Sandfort V, Persson M, Pourmorteza A, Noël PB, Fleischmann D, Willemink MJ. Spectral photon-counting CT in cardiovascular imaging. J Cardiovasc Comput Tomogr 2020; 15:218-225. [PMID: 33358186 DOI: 10.1016/j.jcct.2020.12.005] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/13/2020] [Accepted: 12/17/2020] [Indexed: 12/18/2022]
Abstract
Photon-counting computed tomography (PCCT) is an emerging technology promising to substantially improve cardiovascular imaging. Recent engineering and manufacturing advances by several vendors are expected to imminently launch this new technology into clinical reality. Photon-counting detectors (PCDs) have multiple potential advantages over conventional energy integrating detectors (EIDs) such as the absence of electronic noise, multi-energy capability, and increased spatial resolution. These developments will have different timescales for implementation and will affect different clinical scopes. We describe the technical aspects of PCCT, explain the current developments, and finally discuss potential advantages of PCCT in cardiovascular imaging.
Collapse
|
30
|
Willemink MJ, Coolen BF, Dyvorne H, Robson PM, Bander I, Ishino S, Pruzan A, Sridhar A, Zhang B, Balchandani P, Mani V, Strijkers GJ, Nederveen AJ, Leiner T, Fayad ZA, Mulder WJM, Calcagno C. Ultra-high resolution, 3-dimensional magnetic resonance imaging of the atherosclerotic vessel wall at clinical 7T. PLoS One 2020; 15:e0241779. [PMID: 33315867 PMCID: PMC7735577 DOI: 10.1371/journal.pone.0241779] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 10/21/2020] [Indexed: 12/11/2022] Open
Abstract
Accurate quantification and characterization of atherosclerotic plaques with MRI requires high spatial resolution acquisitions with excellent image quality. The intrinsically better signal-to-noise ratio (SNR) at high-field clinical 7T compared to the widely employed lower field strengths of 1.5 and 3T may yield significant improvements to vascular MRI. However, 7T atherosclerosis imaging also presents specific challenges, related to local transmit coils and B1 field inhomogeneities, which may overshadow these theoretical gains. We present the development and evaluation of 3D, black-blood, ultra-high resolution vascular MRI on clinical high-field 7T in comparison lower-field 3T. These protocols were applied for in vivo imaging of atherosclerotic rabbits, which are often used for development, testing, and validation of translatable cardiovascular MR protocols. Eight atherosclerotic New Zealand White rabbits were imaged on clinical 7T and 3T MRI scanners using 3D, isotropic, high (0.63 mm3) and ultra-high (0.43 mm3) spatial resolution, black-blood MR sequences with extensive spatial coverage. Following imaging, rabbits were sacrificed for validation using fluorescence imaging and histology. Image quality parameters such as SNR and contrast-to-noise ratio (CNR), as well as morphological and functional plaque measurements (plaque area and permeability) were evaluated at both field strengths. Using the same or comparable imaging parameters, SNR and CNR were in general higher at 7T compared to 3T, with a median (interquartiles) SNR gain of +40.3 (35.3-80.1)%, and a median CNR gain of +68.1 (38.5-95.2)%. Morphological and functional parameters, such as vessel wall area and permeability, were reliably acquired at 7T and correlated significantly with corresponding, widely validated 3T vessel wall MRI measurements. In conclusion, we successfully developed 3D, black-blood, ultra-high spatial resolution vessel wall MRI protocols on a 7T clinical scanner. 7T imaging was in general superior to 3T with respect to image quality, and comparable in terms of plaque area and permeability measurements.
Collapse
|
31
|
Willemink MJ. At the heart of innovation: cardiac imaging in 2019. Eur Radiol 2020; 31:11-13. [PMID: 32740812 DOI: 10.1007/s00330-020-07106-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/06/2020] [Accepted: 07/23/2020] [Indexed: 11/30/2022]
|
32
|
Hahn LD, Mistelbauer G, Higashigaito K, Koci M, Willemink MJ, Sailer AM, Fischbein M, Fleischmann D. CT-based True- and False-Lumen Segmentation in Type B Aortic Dissection Using Machine Learning. Radiol Cardiothorac Imaging 2020; 2:e190179. [PMID: 33778582 DOI: 10.1148/ryct.2020190179] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/18/2019] [Accepted: 01/02/2020] [Indexed: 01/25/2023]
Abstract
Purpose To develop a segmentation pipeline for segmentation of aortic dissection CT angiograms into true and false lumina on multiplanar reformations (MPRs) perpendicular to the aortic centerline and derive quantitative morphologic features, specifically aortic diameter and true- or false-lumen cross-sectional area. Materials and Methods An automated segmentation pipeline including two convolutional neural network (CNN) segmentation algorithms was developed. The algorithm derives the aortic centerline, generates MPRs orthogonal to the centerline, and segments the true and false lumina. A total of 153 CT angiograms obtained from 45 retrospectively identified patients (mean age, 50 years; range, 22-79 years) were used to train (n = 103), validate (n = 22), and test (n = 28) the CNN pipeline. Accuracy was evaluated by using the Dice similarity coefficient (DSC). Segmentations were then used to derive the maximal diameter of test-set patients and cross-sectional area profiles of the true and false lumina. Results The segmentation pipeline yielded a mean DSC of 0.873 ± 0.056 for the true lumina and 0.894 ± 0.040 for the false lumina of test-set cases. Automated maximal diameter measurements correlated well with manual measurements (R 2 = 0.95). Profiles of cross-sectional diameter, true-lumen area, and false-lumen area over several follow-up examinations were derived. Conclusion A segmentation pipeline was used to accurately identify true and false lumina on CT angiograms of aortic dissection. These segmentations can be used to obtain diameter and other morphologic parameters for surveillance and risk stratification.Supplemental material is available for this article.© RSNA, 2020.
Collapse
|
33
|
Arges K, Assimes T, Bajaj V, Balu S, Bashir MR, Beskow L, Blanco R, Califf R, Campbell P, Carin L, Christian V, Cousins S, Das M, Dockery M, Douglas PS, Dunham A, Eckstrand J, Fleischmann D, Ford E, Fraulo E, French J, Gambhir SS, Ginsburg GS, Green RC, Haddad F, Hernandez A, Hernandez J, Huang ES, Jaffe G, King D, Koweek LH, Langlotz C, Liao YJ, Mahaffey KW, Marcom K, Marks WJ, Maron D, McCabe R, McCall S, McCue R, Mega J, Miller D, Muhlbaier LH, Munshi R, Newby LK, Pak-Harvey E, Patrick-Lake B, Pencina M, Peterson ED, Rodriguez F, Shore S, Shah S, Shipes S, Sledge G, Spielman S, Spitler R, Schaack T, Swamy G, Willemink MJ, Wong CA. The Project Baseline Health Study: a step towards a broader mission to map human health. NPJ Digit Med 2020; 3:84. [PMID: 32550652 PMCID: PMC7275087 DOI: 10.1038/s41746-020-0290-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Accepted: 05/19/2020] [Indexed: 12/27/2022] Open
Abstract
The Project Baseline Health Study (PBHS) was launched to map human health through a comprehensive understanding of both the health of an individual and how it relates to the broader population. The study will contribute to the creation of a biomedical information system that accounts for the highly complex interplay of biological, behavioral, environmental, and social systems. The PBHS is a prospective, multicenter, longitudinal cohort study that aims to enroll thousands of participants with diverse backgrounds who are representative of the entire health spectrum. Enrolled participants will be evaluated serially using clinical, molecular, imaging, sensor, self-reported, behavioral, psychological, environmental, and other health-related measurements. An initial deeply phenotyped cohort will inform the development of a large, expanded virtual cohort. The PBHS will contribute to precision health and medicine by integrating state of the art testing, longitudinal monitoring and participant engagement, and by contributing to the development of an improved platform for data sharing and analysis.
Collapse
|
34
|
Willemink MJ, Koszek WA, Hardell C, Wu J, Fleischmann D, Harvey H, Folio LR, Summers RM, Rubin DL, Lungren MP. Preparing Medical Imaging Data for Machine Learning. Radiology 2020; 295:4-15. [PMID: 32068507 PMCID: PMC7104701 DOI: 10.1148/radiol.2020192224] [Citation(s) in RCA: 324] [Impact Index Per Article: 81.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 12/03/2019] [Accepted: 12/30/2019] [Indexed: 12/19/2022]
Abstract
Artificial intelligence (AI) continues to garner substantial interest in medical imaging. The potential applications are vast and include the entirety of the medical imaging life cycle from image creation to diagnosis to outcome prediction. The chief obstacles to development and clinical implementation of AI algorithms include availability of sufficiently large, curated, and representative training data that includes expert labeling (eg, annotations). Current supervised AI methods require a curation process for data to optimally train, validate, and test algorithms. Currently, most research groups and industry have limited data access based on small sample sizes from small geographic areas. In addition, the preparation of data is a costly and time-intensive process, the results of which are algorithms with limited utility and poor generalization. In this article, the authors describe fundamental steps for preparing medical imaging data in AI algorithm development, explain current limitations to data curation, and explore new approaches to address the problem of data availability.
Collapse
|
35
|
Jubran A, Schnittger I, Tremmel J, Vedant P, Rogers I, Becker HC, Yang S, Mastrodicasa D, Willemink MJ, Fleischmann D, Nieman K. Ct-angiography Based Fractional Flow Reserve Compared To Catheter-based, Dobutamine-stress Diastolic Fractional Flow Reserve In Symptomatic Patients With Myocardial Bridges. J Cardiovasc Comput Tomogr 2020. [DOI: 10.1016/j.jcct.2019.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
36
|
Willemink MJ, Maret E, Moneghetti KJ, Kim JB, Haddad F, Kobayashi Y, Nishi T, Nieman K, Cauwenberghs N, Kuznetsova T, Higashigaito K, Sailer AM, Yeung AC, Lee AM, Miller DC, Fischbein M, Fearon WF, Fleischmann D. Incremental Value of Aortomitral Continuity Calcification for Risk Assessment after Transcatheter Aortic Valve Replacement. Radiol Cardiothorac Imaging 2019; 1:e190067. [PMID: 33778530 DOI: 10.1148/ryct.2019190067] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 08/10/2019] [Accepted: 09/05/2019] [Indexed: 11/11/2022]
Abstract
Purpose To investigate the association of aortomitral continuity calcification (AMCC) with all-cause mortality, postprocedural paravalvular leak (PVL), and prolonged hospital stay in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods The authors retrospectively evaluated 329 patients who underwent TAVR between March 2013 and March 2016. AMCC, aortic valve calcification (AVC), and coronary artery calcification (CAC) were quantified by using preprocedural CT. Pre-procedural Society of Thoracic Surgeons (STS) score was recorded. Associations between baseline AMCC, AVC, and CAC and 1-year mortality, PVL, and hospital stay longer than 7 days were analyzed. Results The median follow-up was 415 days (interquartiles, 344-727 days). After 1 year, 46 of the 329 patients (14%) died and 52 (16%) were hospitalized for more than 7 days. Of the 326 patients who underwent postprocedural echocardiography, 147 (45%) had postprocedural PVL. The CAC score (hazard ratio: 1.11 per 500 points) and AMCC mass (hazard ratio: 1.13 per 500 mg) were associated with 1-year mortality. AVC mass (odds ratio: 1.93 per 100 mg) was associated with postprocedural PVL. Only the STS score was associated with prolonged hospital stay (odds ratio: 1.19 per point). Conclusion AMCC is associated with mortality within 1 year after TAVR and substantially improves individual risk classification when added to a model consisting of STS score and AVC mass only.Supplemental material is available for this article.© RSNA, 2019See also the commentary by Brown and Leipsic in this issue.
Collapse
|
37
|
van Hamersvelt RW, Voskuil M, de Jong PA, Willemink MJ, Išgum I, Leiner T. Diagnostic Performance of On-Site Coronary CT Angiography-derived Fractional Flow Reserve Based on Patient-specific Lumped Parameter Models. Radiol Cardiothorac Imaging 2019; 1:e190036. [PMID: 33778519 DOI: 10.1148/ryct.2019190036] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 06/14/2019] [Accepted: 06/20/2019] [Indexed: 11/11/2022]
Abstract
Purpose To evaluate the diagnostic performance of a prototype on-site coronary CT angiography-derived fractional flow reserve (CT FFR) algorithm, based on patient-specific lumped parameter models, for the detection of functionally significant stenosis defined by invasive FFR, and to compare the performance to anatomic evaluation of stenosis degree. Materials and Methods In this retrospective feasibility study, 77 vessels in 57 patients (42 of 57 [74%]) men; mean age, 58.5 years ± 9.2 [standard deviation]) who underwent clinically indicated coronary CT angiography within 60 days prior to an invasive FFR measurement were analyzed. Invasive FFR less than or equal to 0.80 was used to indicate a functionally significant stenosis. Diagnostic performance of CT FFR was evaluated and compared with evaluation of stenosis degree. Analysis was performed on a per-vessel basis. Results Invasive FFR revealed functionally significant stenoses in 37 vessels (48%). CT FFR showed a significantly increased ability to indicate functionally significant stenosis (area under the receiver operating characteristic curve [AUC], 0.87) compared with degree of stenosis at coronary CT angiography (AUC, 0.70; ΔAUC 0.17; P < .01). Using a cutoff of less than or equal to 0.80 for CT FFR and greater than or equal to 50% degree of stenosis at coronary CT angiography to indicate a significant stenosis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 33 of 37 (89.2%), 31 of 40 (77.5%), 33 of 42 (78.6%), 31 of 35 (88.6%), and 64 of 77 (83.1%), respectively, for CT FFR, and 33 of 37 (89.2%), 17 of 40 (42.5%), 33 of 56 (58.9%), 17 of 21 (81.0%), and 50 of 77 (64.9%), respectively, for degree of stenosis at coronary CT angiography. Conclusion Diagnostic performance of on-site CT FFR was superior to stenosis evaluation at coronary CT angiography for identification of functionally significant coronary artery stenosis in patients suspected of having or known to have coronary artery disease.© RSNA, 2019See also commentary by Schoepf et al.
Collapse
|
38
|
Chin AS, Willemink MJ, Kino A, Hinostroza V, Sailer AM, Fischbein MP, Mitchell RS, Berry GJ, Miller DC, Fleischmann D. Acute Limited Intimal Tears of the Thoracic Aorta. J Am Coll Cardiol 2019; 71:2773-2785. [PMID: 29903350 DOI: 10.1016/j.jacc.2018.03.531] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 03/04/2018] [Accepted: 03/21/2018] [Indexed: 10/14/2022]
Abstract
BACKGROUND Limited intimal tears (LITs) of the aorta (Class 3 dissection variant) are the least common form of aortic pathology in patients presenting with acute aortic syndrome (AAS). LITs are difficult to detect on imaging and may be underappreciated. OBJECTIVES This study sought to describe the frequency, pathology, treatment, and outcome of LITs compared with other AAS, and to demonstrate that LITs can be detected pre-operatively by contemporary imaging. METHODS The authors retrospectively reviewed 497 patients admitted for 513 AAS events at a single academic aortic center between 2003 and 2012. AAS were classified into classic dissection (AD), intramural hematoma, LIT, penetrating atherosclerotic ulcer, and rupturing thoracic aortic aneurysm. The prevalence, pertinent risk factors, and detailed imaging findings with surgical and pathological correlation of LITs are described. Management, early outcomes, and late mortality are reported. RESULTS Among 497 patients with AAS, the authors identified 24 LITs (4.8% of AAS) in 16 men and 8 women (17 type A, 7 type B). Patients with LITs were older than those with AD, and type A LITs had similarly dilated ascending aortas as type A AD. Three patients presented with rupture. Eleven patients underwent urgent surgical aortic replacement, and 2 patients underwent endovascular repair. Medial degeneration was present in all surgical specimens. In-hospital mortality was 4% (1 of 24), and in total, 5 patients with LIT died subsequently at 1.5 years (interquartile range [IQR]: 0.3 to 2.5 years). Computed tomography imaging detected all but 1 LIT, best visualized on volume-rendered images. CONCLUSIONS LITs are rare acute aortic lesions within the dissection spectrum, with similar presentation, complications, and outcomes compared with AD and intramural hematoma. Awareness of this lesion allows pre-operative diagnosis using high-quality computed tomography angiography.
Collapse
|
39
|
Jubran A, Willemink MJ, Nieman K. Coronary CT in Patients with a History of PCI or CABG: Helpful or Harmful? CURRENT CARDIOVASCULAR IMAGING REPORTS 2019. [DOI: 10.1007/s12410-019-9496-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
40
|
van Hamersvelt RW, Išgum I, de Jong PA, Cramer MJM, Leenders GEH, Willemink MJ, Voskuil M, Leiner T. Application of speCtraL computed tomogrAphy to impRove specIficity of cardiac compuTed tomographY (CLARITY study): rationale and design. BMJ Open 2019; 9:e025793. [PMID: 30826767 PMCID: PMC6429912 DOI: 10.1136/bmjopen-2018-025793] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
INTRODUCTION Anatomic stenosis evaluation on coronary CT angiography (CCTA) lacks specificity in indicating the functional significance of a stenosis. Recent developments in CT techniques (including dual-layer spectral detector CT [SDCT] and static stress CT perfusion [CTP]) and image analyses (including fractional flow reserve [FFR] derived from CCTA images [FFRCT] and deep learning analysis [DL]) are potential strategies to increase the specificity of CCTA by combining both anatomical and functional information in one investigation. The aim of the current study is to assess the diagnostic performance of (combinations of) SDCT, CTP, FFRCT and DL for the identification of functionally significant coronary artery stenosis. METHODS AND ANALYSIS Seventy-five patients aged 18 years and older with stable angina and known coronary artery disease and scheduled to undergo clinically indicated invasive FFR will be enrolled. All subjects will undergo the following SDCT scans: coronary calcium scoring, static stress CTP, rest CCTA and if indicated (history of myocardial infarction) a delayed enhancement acquisition. Invasive FFR of ≤0.80, measured within 30 days after the SDCT scans, will be used as reference to indicate a functionally significant stenosis. The primary study endpoint is the diagnostic performance of SDCT (including CTP) for the identification of functionally significant coronary artery stenosis. Secondary study endpoint is the diagnostic performance of SDCT, CTP, FFRCT and DL separately and combined for the identification of functionally significant coronary artery stenosis. ETHICS AND DISSEMINATION Ethical approval was obtained. All subjects will provide written informed consent. Study findings will be disseminated through peer-reviewed conference presentations and journal publications. TRIAL REGISTRATION NUMBER NCT03139006; Pre-results.
Collapse
|
41
|
den Harder AM, de Boer E, Lagerweij SJ, Boomsma MF, Schilham AMR, Willemink MJ, Milles J, Leiner T, Budde RPJ, de Jong PA. Emphysema quantification using chest CT: influence of radiation dose reduction and reconstruction technique. Eur Radiol Exp 2018; 2:30. [PMID: 30402740 PMCID: PMC6220000 DOI: 10.1186/s41747-018-0064-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 08/06/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Computed tomography (CT) emphysema quantification is affected by both radiation dose (i.e. image noise) and reconstruction technique. At reduced dose, filtered back projection (FBP) results in an overestimation of the amount of emphysema due to higher noise levels, while the use of iterative reconstruction (IR) can result in an underestimation due to reduced noise. The objective of this study was to determine the influence of dose reduction and hybrid IR (HIR) or model-based IR (MIR) on CT emphysema quantification. METHODS Twenty-two patients underwent inspiratory chest CT scan at routine radiation dose and at 45%, 60% and 75% reduced radiation dose. Acquisitions were reconstructed with FBP, HIR and MIR. Emphysema was quantified using the 15th percentile of the attenuation curve and the percentage of voxels below -950 HU. To determine whether the use of a different percentile or HU threshold is more accurate at reduced dose levels and with IR, additional measurements were performed using different percentiles and HU thresholds to determine the optimal combination. RESULTS Dose reduction resulted in a significant overestimation of emphysema, while HIR and MIR resulted in an underestimation. Lower HU thresholds with FBP at reduced dose and higher HU thresholds with HIR and MIR resulted in emphysema percentages comparable to the reference. The 15th percentile quantification method showed similar results as the HU threshold method. CONCLUSIONS This within-patients study showed that CT emphysema quantification is significantly affected by dose reduction and IR. This can potentially be solved by adapting commonly used thresholds.
Collapse
|
42
|
Willemink MJ, Noël PB. The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. Eur Radiol 2018; 29:2185-2195. [PMID: 30377791 PMCID: PMC6443602 DOI: 10.1007/s00330-018-5810-7] [Citation(s) in RCA: 259] [Impact Index Per Article: 43.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 09/12/2018] [Accepted: 09/27/2018] [Indexed: 12/22/2022]
Abstract
Abstract The first CT scanners in the early 1970s already used iterative reconstruction algorithms; however, lack of computational power prevented their clinical use. In fact, it took until 2009 for the first iterative reconstruction algorithms to come commercially available and replace conventional filtered back projection. Since then, this technique has caused a true hype in the field of radiology. Within a few years, all major CT vendors introduced iterative reconstruction algorithms for clinical routine, which evolved rapidly into increasingly advanced reconstruction algorithms. The complexity of algorithms ranges from hybrid-, model-based to fully iterative algorithms. As a result, the number of scientific publications on this topic has skyrocketed over the last decade. But what exactly has this technology brought us so far? And what can we expect from future hardware as well as software developments, such as photon-counting CT and artificial intelligence? This paper will try answer those questions by taking a concise look at the overall evolution of CT image reconstruction and its clinical implementations. Subsequently, we will give a prospect towards future developments in this domain. Key Points • Advanced CT reconstruction methods are indispensable in the current clinical setting. • IR is essential for photon-counting CT, phase-contrast CT, and dark-field CT. • Artificial intelligence will potentially further increase the performance of reconstruction methods.
Collapse
|
43
|
Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: Technical Principles and Clinical Prospects. Radiology 2018; 289:293-312. [PMID: 30179101 DOI: 10.1148/radiol.2018172656] [Citation(s) in RCA: 491] [Impact Index Per Article: 81.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Photon-counting CT is an emerging technology with the potential to dramatically change clinical CT. Photon-counting CT uses new energy-resolving x-ray detectors, with mechanisms that differ substantially from those of conventional energy-integrating detectors. Photon-counting CT detectors count the number of incoming photons and measure photon energy. This technique results in higher contrast-to-noise ratio, improved spatial resolution, and optimized spectral imaging. Photon-counting CT can reduce radiation exposure, reconstruct images at a higher resolution, correct beam-hardening artifacts, optimize the use of contrast agents, and create opportunities for quantitative imaging relative to current CT technology. In this review, the authors will explain the technical principles of photon-counting CT in nonmathematical terms for radiologists and clinicians. Following a general overview of the current status of photon-counting CT, they will explain potential clinical applications of this technology.
Collapse
|
44
|
Vonder M, van der Werf NR, Leiner T, Greuter MJ, Fleischmann D, Vliegenthart R, Oudkerk M, Willemink MJ. The impact of dose reduction on the quantification of coronary artery calcifications and risk categorization: A systematic review. J Cardiovasc Comput Tomogr 2018; 12:352-363. [DOI: 10.1016/j.jcct.2018.06.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Revised: 05/18/2018] [Accepted: 06/11/2018] [Indexed: 11/29/2022]
|
45
|
van Hamersvelt RW, Eijsvoogel NG, Mihl C, de Jong PA, Schilham AMR, Buls N, Das M, Leiner T, Willemink MJ. Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study. Int J Cardiovasc Imaging 2018. [PMID: 29516228 DOI: 10.1007/s10554-018-1329-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
We investigated the feasibility and extent to which iodine concentration can be reduced in computed tomography angiography imaging of the aorta and coronary arteries using low tube voltage and virtual monochromatic imaging of 3 major dual-energy CT (DECT) vendors. A circulation phantom was imaged with dual source CT (DSCT), gemstone spectral imaging (GSI) and dual-layer spectral detector CT (SDCT). For each scanner, a reference scan was acquired at 120 kVp using routine iodine concentration (300 mg I/ml). Subsequently, scans were acquired at lowest possible tube potential (70, 80, 80 kVp, respectively), and DECT-mode (80/150Sn, 80/140 and 120 kVp, respectively) in arterial phase after administration of iodine (300, 240, 180, 120, 60, 30 mg I/ml). Objective image quality was evaluated using attenuation, CNR and dose corrected CNR (DCCNR) measured in the aorta and left main coronary artery. Average DCCNR at reference was 227.0, 39.7 and 60.2 for DSCT, GSI and SDCT. Maximum iodine concentration reduction without loss of DCCNR was feasible down to 180 mg I/ml (40% reduced) for DSCT (DCCNR 467.1) and GSI (DCCNR 46.1) using conventional CT low kVp, and 120 mg I/ml (60% reduced) for SDCT (DCCNR 171.5) using DECT mode. Low kVp scanning and DECT allows for 40-60% iodine reduction without loss in image quality compared to reference. Optimal scan protocol and to which extent varies per vendor. Further patient studies are needed to extend and translate our findings to clinical practice.
Collapse
|
46
|
den Harder AM, Willemink MJ, van Doormaal PJ, Wessels FJ, Lock MTWT, Schilham AMR, Budde RPJ, Leiner T, de Jong PA. Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study. Eur Radiol 2018; 28:143-150. [PMID: 28695359 PMCID: PMC5717126 DOI: 10.1007/s00330-017-4929-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Accepted: 06/05/2017] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.
Collapse
|
47
|
van der Werf NR, Willemink MJ, Willems TP, Vliegenthart R, Greuter MJW, Leiner T. Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study. Int J Cardiovasc Imaging 2017; 34:959-966. [PMID: 29285727 DOI: 10.1007/s10554-017-1293-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 12/19/2017] [Indexed: 12/20/2022]
Abstract
To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60-75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1-CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.
Collapse
|
48
|
den Harder AM, Bangert F, van Hamersvelt RW, Leiner T, Milles J, Schilham AMR, Willemink MJ, de Jong PA. The Effects of Iodine Attenuation on Pulmonary Nodule Volumetry using Novel Dual-Layer Computed Tomography Reconstructions. Eur Radiol 2017; 27:5244-5251. [PMID: 28677062 PMCID: PMC5674131 DOI: 10.1007/s00330-017-4938-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Revised: 05/22/2017] [Accepted: 06/08/2017] [Indexed: 12/19/2022]
Abstract
OBJECTIVES To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. METHODS A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. RESULTS Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. CONCLUSIONS Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. KEY POINTS • Pulmonary nodule volumes were measured on virtual non-contrast and mono-energetic reconstructions • Mono-energetic reconstructions showed that higher attenuation results in larger volumes • This may explain the reported nodule volume underestimation on non-contrast enhanced CT • Mostly metastatic pulmonary nodules were evaluated, results might differ for benign nodules.
Collapse
|
49
|
van Hamersvelt RW, de Jong PA, Dessing TC, Leiner T, Willemink MJ. Dual energy CT to reveal pseudo leakage of frozen elephant trunk. J Cardiovasc Comput Tomogr 2017; 11:240-241. [DOI: 10.1016/j.jcct.2016.11.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 11/06/2016] [Indexed: 10/20/2022]
|
50
|
van Hamersvelt RW, Schilham AMR, Engelke K, den Harder AM, de Keizer B, Verhaar HJ, Leiner T, de Jong PA, Willemink MJ. Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study. Eur Radiol 2017; 27:4351-4359. [PMID: 28374079 PMCID: PMC5579207 DOI: 10.1007/s00330-017-4801-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 03/13/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. METHODS Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). RESULTS At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm3 (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm3 (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R2 ≥ 0.970, P < 0.001) with DXA were found. CONCLUSIONS SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. KEY POINTS • Dual-layer spectral detector CT allows for accurate bone mineral density quantification. • BMD measurements on SDCT are strongly linearly correlated to DXA. • SDCT, acquired for several indications, may allow for evaluation of osteoporosis. • This potentially opens up the possibility for opportunistic osteoporosis screening.
Collapse
|