26
|
Agliardi G, Liuzzi AR, Hotblack A, De Feo D, Núñez N, Friebel E, Nannini F, Roberts T, Ramasawmy R, Stowe C, Williams I, Siow B, Lythgoe M, Kalber T, Quezada S, Pule M, Tugues S, Becher B, Straathof K. IMMU-16. INTRA-TUMOURAL IL-12 DELIVERY ENABLES CAR T-CELL IMMUNOTHERAPY FOR HIGH-GRADE GLIOMA. Neuro Oncol 2020. [PMCID: PMC7715834 DOI: 10.1093/neuonc/noaa222.372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Treatment with T-cells redirected to tumour specificity with a chimeric antigen receptor (CAR) may be well suited to treat intracranial tumours due to the ability of T-cells to access the central nervous system and migrate to infiltrative sites of disease. In adult glioblastoma, a case report of local and distant eradication of intracranial and spinal tumour deposits following intraventricular infusion of IL13Ra2-CAR T-cells indicates the potential of this approach. However, in contrast to the sustained complete remissions observed in haematological malignancies, in the majority of patients with glioblastoma CAR T-cell therapy has not resulted in clinical benefit. Tumour heterogeneity and the highly immune inhibitory tumour microenvironment (TME) are likely key barriers to achieving durable anti-tumour immunity. Here use intra-tumoural administration of IL-12 to enable CAR T-cell immunity. We employed CAR-T cells targeting the tumour-specific epidermal growth factor variant III (EGFRvIII). In an immunocompetent orthotopic mouse model of high-grade glioma, we show that CAR-T cells alone failed to control fully established tumour, but when combined with a single, locally delivered dose of IL-12, durable antitumor responses were achieved. IL-12 not only boosted cytotoxicity of CAR T-cells, but also reshaped the TME driving increased infiltration of proinflammatory CD4+ T-cells, decreased numbers of regulatory T-cells (Tregs) and activation of the myeloid compartment. Critically, immunotherapy enabling benefits of IL-12 were achieved with minimal systemic effects. Our findings show that local delivery of IL-12 is an effective adjuvant for CAR-T cell therapy for high-grade glioma. Assessment of application in high-risk childhood brain tumours is ongoing.
Collapse
|
27
|
Roberts TA, Hyare H, Agliardi G, Hipwell B, d'Esposito A, Ianus A, Breen-Norris JO, Ramasawmy R, Taylor V, Atkinson D, Punwani S, Lythgoe MF, Siow B, Brandner S, Rees J, Panagiotaki E, Alexander DC, Walker-Samuel S. Noninvasive diffusion magnetic resonance imaging of brain tumour cell size for the early detection of therapeutic response. Sci Rep 2020; 10:9223. [PMID: 32514049 PMCID: PMC7280197 DOI: 10.1038/s41598-020-65956-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 05/07/2020] [Indexed: 01/09/2023] Open
Abstract
Cancer cells differ in size from those of their host tissue and are known to change in size during the processes of cell death. A noninvasive method for monitoring cell size would be highly advantageous as a potential biomarker of malignancy and early therapeutic response. This need is particularly acute in brain tumours where biopsy is a highly invasive procedure. Here, diffusion MRI data were acquired in a GL261 glioma mouse model before and during treatment with Temozolomide. The biophysical model VERDICT (Vascular Extracellular and Restricted Diffusion for Cytometry in Tumours) was applied to the MRI data to quantify multi-compartmental parameters connected to the underlying tissue microstructure, which could potentially be useful clinical biomarkers. These parameters were compared to ADC and kurtosis diffusion models, and, measures from histology and optical projection tomography. MRI data was also acquired in patients to assess the feasibility of applying VERDICT in a range of different glioma subtypes. In the GL261 gliomas, cellular changes were detected according to the VERDICT model in advance of gross tumour volume changes as well as ADC and kurtosis models. VERDICT parameters in glioblastoma patients were most consistent with the GL261 mouse model, whilst displaying additional regions of localised tissue heterogeneity. The present VERDICT model was less appropriate for modelling more diffuse astrocytomas and oligodendrogliomas, but could be tuned to improve the representation of these tumour types. Biophysical modelling of the diffusion MRI signal permits monitoring of brain tumours without invasive intervention. VERDICT responds to microstructural changes induced by chemotherapy, is feasible within clinical scan times and could provide useful biomarkers of treatment response.
Collapse
|
28
|
Restivo MC, Ramasawmy R, Bandettini WP, Herzka DA, Campbell-Washburn AE. Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI. Magn Reson Med 2020; 84:2364-2375. [PMID: 32291845 DOI: 10.1002/mrm.28278] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 03/10/2020] [Accepted: 03/13/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE Low-field MRI offers favorable physical properties for SNR-efficient long readout acquisitions such as spiral and EPI. We used a 0.55 tesla (T) MRI system equipped with high-performance hardware to increase the sampling duty cycle and extend the TR of balanced steady-state free precession (bSSFP) cardiac cine acquisitions, which typically are limited by banding artifacts. METHODS We developed a high-efficiency spiral in-out bSSFP acquisition, with zeroth- and first-gradient moment nulling, and an EPI bSSFP acquisition for cardiac cine imaging using a contemporary MRI system modified to operate at 0.55T. Spiral in-out and EPI bSSFP cine protocols, with TR = 8 ms, were designed to maintain both spatiotemporal resolution and breath-hold length. Simulations, phantom imaging, and healthy volunteer imaging studies (n = 12) were performed to assess SNR and image quality using these high sampling duty-cycle bSSFP sequences. RESULTS Spiral in-out bSSFP performed favorably at 0.55T and generated good image quality, whereas EPI bSSFP suffered motion and flow artifacts. There was no difference in ejection fraction comparing spiral in-out with standard Cartesian imaging. Moreover, human images demonstrated a 79% ± 21% increase in myocardial SNR using spiral in-out bSSFP and 50% ± 14% increase in SNR using EPI bSSFP as compared with the reference Cartesian acquisition. Spiral in-out acquisitions at 0.55T recovered 69% ± 14% of the myocardial SNR at 1.5T. CONCLUSION Efficient bSSFP spiral in-out provided high-quality cardiac cine imaging and SNR recovery on a high-performance 0.55T MRI system.
Collapse
|
29
|
Campbell-Washburn AE, Ramasawmy R, Restivo MC, Bhattacharya I, Basar B, Herzka DA, Hansen MS, Rogers T, Bandettini WP, McGuirt DR, Mancini C, Grodzki D, Schneider R, Majeed W, Bhat H, Xue H, Moss J, Malayeri AA, Jones EC, Koretsky AP, Kellman P, Chen MY, Lederman RJ, Balaban RS. Opportunities in Interventional and Diagnostic Imaging by Using High-Performance Low-Field-Strength MRI. Radiology 2019; 293:384-393. [PMID: 31573398 PMCID: PMC6823617 DOI: 10.1148/radiol.2019190452] [Citation(s) in RCA: 191] [Impact Index Per Article: 38.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 08/06/2019] [Accepted: 08/15/2019] [Indexed: 12/24/2022]
Abstract
Background Commercial low-field-strength MRI systems are generally not equipped with state-of-the-art MRI hardware, and are not suitable for demanding imaging techniques. An MRI system was developed that combines low field strength (0.55 T) with high-performance imaging technology. Purpose To evaluate applications of a high-performance low-field-strength MRI system, specifically MRI-guided cardiovascular catheterizations with metallic devices, diagnostic imaging in high-susceptibility regions, and efficient image acquisition strategies. Materials and Methods A commercial 1.5-T MRI system was modified to operate at 0.55 T while maintaining high-performance hardware, shielded gradients (45 mT/m; 200 T/m/sec), and advanced imaging methods. MRI was performed between January 2018 and April 2019. T1, T2, and T2* were measured at 0.55 T; relaxivity of exogenous contrast agents was measured; and clinical applications advantageous at low field were evaluated. Results There were 83 0.55-T MRI examinations performed in study participants (45 women; mean age, 34 years ± 13). On average, T1 was 32% shorter, T2 was 26% longer, and T2* was 40% longer at 0.55 T compared with 1.5 T. Nine metallic interventional devices were found to be intrinsically safe at 0.55 T (<1°C heating) and MRI-guided right heart catheterization was performed in seven study participants with commercial metallic guidewires. Compared with 1.5 T, reduced image distortion was shown in lungs, upper airway, cranial sinuses, and intestines because of improved field homogeneity. Oxygen inhalation generated lung signal enhancement of 19% ± 11 (standard deviation) at 0.55 T compared with 7.6% ± 6.3 at 1.5 T (P = .02; five participants) because of the increased T1 relaxivity of oxygen (4.7e-4 mmHg-1sec-1). Efficient spiral image acquisitions were amenable to low field strength and generated increased signal-to-noise ratio compared with Cartesian acquisitions (P < .02). Representative imaging of the brain, spine, abdomen, and heart generated good image quality with this system. Conclusion This initial study suggests that high-performance low-field-strength MRI offers advantages for MRI-guided catheterizations with metal devices, MRI in high-susceptibility regions, and efficient imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Grist in this issue.
Collapse
|
30
|
Finnerty E, Ramasawmy R, O’Callaghan J, Connell JJ, Lythgoe M, Shmueli K, Thomas DL, Walker‐Samuel S. Noninvasive quantification of oxygen saturation in the portal and hepatic veins in healthy mice and those with colorectal liver metastases using QSM MRI. Magn Reson Med 2019; 81:2666-2675. [PMID: 30450573 PMCID: PMC6588010 DOI: 10.1002/mrm.27571] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 09/10/2018] [Accepted: 09/26/2018] [Indexed: 12/30/2022]
Abstract
PURPOSE This preclinical study investigated the use of QSM MRI to noninvasively measure venous oxygen saturation (SvO2) in the hepatic and portal veins. METHODS QSM data were acquired from a cohort of healthy mice (n = 10) on a 9.4 Tesla MRI scanner under normoxic and hyperoxic conditions. Susceptibility was measured in the portal and hepatic veins and used to calculate SvO2 in each vessel under each condition. Blood was extracted from the inferior vena cava of 3 of the mice under each condition, and SvO2 was measured with a blood gas analyzer for comparison. QSM data were also acquired from a cohort of mice bearing liver tumors under normoxic conditions. Susceptibility was measured, and SvO2 calculated in the portal and hepatic veins and compared to the healthy mice. Statistical significance was assessed using a Wilcoxon matched-pairs signed rank test (normoxic vs. hyperoxic) or a Mann-Whitney test (healthy vs. tumor bearing). RESULTS SvO2 calculated from QSM measurements in healthy mice under hyperoxia showed significant increases of 15% in the portal vein (P < 0.05) and 21% in the hepatic vein (P < 0.01) versus normoxia. These values agreed with inferior vena cava measurements from the blood gas analyzer (26% increase). SvO2 in the hepatic vein was significantly lower in the colorectal liver metastases cohort (30% ± 11%) than the healthy mice (53% ± 17%) (P < 0.05); differences in the portal vein were not significant. CONCLUSION QSM is a feasible tool for noninvasively measuring SvO2 in the liver and can detect differences due to increased oxygen consumption in livers bearing colorectal metastases.
Collapse
|
31
|
Restivo MC, Campbell-Washburn AE, Kellman P, Xue H, Ramasawmy R, Hansen MS. A framework for constraining image SNR loss due to MR raw data compression. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 32:213-225. [PMID: 30361947 DOI: 10.1007/s10334-018-0709-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 10/03/2018] [Accepted: 10/15/2018] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Computationally intensive image reconstruction algorithms can be used online during MRI exams by streaming data to remote high-performance computers. However, data acquisition rates often exceed the bandwidth of the available network resources creating a bottleneck. Data compression is, therefore, desired to ensure fast data transmission. METHODS The added noise variance due to compression was determined through statistical analysis for two compression libraries (one custom and one generic) that were implemented in this framework. Limiting the compression error variance relative to the measured thermal noise allowed for image signal-to-noise ratio loss to be explicitly constrained. RESULTS Achievable compression ratios are dependent on image SNR, user-defined SNR loss tolerance, and acquisition type. However, a 1% reduction in SNR yields approximately four to ninefold compression ratios across MRI acquisition strategies. For free-breathing cine data reconstructed in the cloud, the streaming bandwidth was reduced from 37 to 6.1 MB/s, alleviating the network transmission bottleneck. CONCLUSION Our framework enabled data compression for online reconstructions and allowed SNR loss to be constrained based on a user-defined SNR tolerance. This practical tool will enable real-time data streaming and greater than fourfold faster cloud upload times.
Collapse
|
32
|
Zhu Y, Ramasawmy R, Johnson SP, Taylor V, Gibb A, Pedley RB, Chattopadhyay N, Lythgoe MF, Golay X, Bradley D, Walker-Samuel S. Non-invasive imaging of disrupted protein homeostasis induced by proteasome inhibitor treatment using chemical exchange saturation transfer MRI. Sci Rep 2018; 8:15068. [PMID: 30305717 PMCID: PMC6180115 DOI: 10.1038/s41598-018-33549-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 10/02/2018] [Indexed: 11/09/2022] Open
Abstract
Proteasome inhibitors (PIs) are now standard of care for several cancers, and noninvasive biomarkers of treatment response are critically required for early patient stratification and treatment personalization. The present study evaluated whether chemical exchange (CEST) magnetic resonance imaging (MRI) can provide measurements that can be used as the noninvasive biomarkers of proteasome inhibition, alongside diffusion MRI and relaxometry. The sensitivity of human colorectal carcinoma cells to the PI Ixazomib was assessed via in vitro and in vivo dose-response experiments. Acute in vivo response to Ixazomib was assessed at three dosing concentrations, using CEST MRI (amide, amine, hydroxyl signals), diffusion MRI (ADC) and relaxometry (T1, T2). These responses were further evaluated with the known histological markers for Ixazomib and Bradford assay ex vivo. The CEST signal from amides and amines increased in proportion to Ixazomib dose in colorectal cancer xenografts. The cell lines differed in their sensitivity to Ixazomib, which was reflected in the MRI measurements. A mild stimulation in tumor growth was observed at low Ixazomib doses. Our results identify CEST MRI as a promising method for safely and noninvasively monitoring disrupted tumor protein homeostasis induced by proteasome inhibitor treatment, and for stratifying sensitivity between tumor types.
Collapse
|
33
|
d'Esposito A, Sweeney PW, Ali M, Saleh M, Ramasawmy R, Roberts TA, Agliardi G, Desjardins A, Lythgoe MF, Pedley RB, Shipley R, Walker-Samuel S. Computational fluid dynamics with imaging of cleared tissue and of in vivo perfusion predicts drug uptake and treatment responses in tumours. Nat Biomed Eng 2018; 2:773-787. [PMID: 31015649 DOI: 10.1038/s41551-018-0306-y] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Accepted: 09/06/2018] [Indexed: 01/02/2023]
Abstract
Understanding the uptake of a drug by diseased tissue, and the drug's subsequent spatiotemporal distribution, are central factors in the development of effective targeted therapies. However, the interaction between the pathophysiology of diseased tissue and individual therapeutic agents can be complex, and can vary across tissue types and across subjects. Here, we show that the combination of mathematical modelling, high-resolution optical imaging of intact and optically cleared tumour tissue from animal models, and in vivo imaging of vascular perfusion predicts the heterogeneous uptake, by large tissue samples, of specific therapeutic agents, as well as their spatiotemporal distribution. In particular, by using murine models of colorectal cancer and glioma, we report and validate predictions of steady-state blood flow and intravascular and interstitial fluid pressure in tumours, of the spatially heterogeneous uptake of chelated gadolinium by tumours, and of the effect of a vascular disrupting agent on tumour vasculature.
Collapse
|
34
|
Ramasawmy R, Rogers T, Alcantar MA, McGuirt DR, Khan JM, Kellman P, Xue H, Faranesh AZ, Campbell-Washburn AE, Lederman RJ, Herzka DA. Blood volume measurement using cardiovascular magnetic resonance and ferumoxytol: preclinical validation. J Cardiovasc Magn Reson 2018; 20:62. [PMID: 30201013 PMCID: PMC6131893 DOI: 10.1186/s12968-018-0486-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 08/20/2018] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND The hallmark of heart failure is increased blood volume. Quantitative blood volume measures are not conveniently available and are not tested in heart failure management. We assess ferumoxytol, a marketed parenteral iron supplement having a long intravascular half-life, to measure the blood volume with cardiovascular magnetic resonance (CMR). METHODS Swine were administered 0.7 mg/kg ferumoxytol and blood pool T1 was measured repeatedly for an hour to characterize contrast agent extraction and subsequent effect on Vblood estimates. We compared CMR blood volume with a standard carbon monoxide rebreathing method. We then evaluated three abbreviated acquisition protocols for bias and precision. RESULTS Mean plasma volume estimated by ferumoxytol was 61.9 ± 4.3 ml/kg. After adjustment for hematocrit the resultant mean blood volume was 88.1 ± 9.4 ml/kg, which agreed with carbon monoxide measures (91.1 ± 18.9 ml/kg). Repeated measurements yielded a coefficient of variation of 6.9%, and Bland-Altman repeatability coefficient of 14%. The blood volume estimates with abbreviated protocols yielded small biases (mean differences between 0.01-0.06 L) and strong correlations (r2 between 0.97-0.99) to the reference values indicating clinical feasibility. CONCLUSIONS In this swine model, ferumoxytol CMR accurately measures plasma volume, and with correction for hematocrit, blood volume. Abbreviated protocols can be added to diagnostic CMR examination for heart failure within 8 min.
Collapse
|
35
|
Yaras YS, Satir S, Ozsoy C, Ramasawmy R, Campbell-Washburn AE, Lederman RJ, Kocaturk O, Degertekin FL. Acousto-Optic Catheter Tracking Sensor for Interventional MRI Procedures. IEEE Trans Biomed Eng 2018; 66:1148-1154. [PMID: 30188810 DOI: 10.1109/tbme.2018.2868830] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers. METHODS The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5 T MRI system in comparison with an active tracking marker. RESULTS Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment. CONCLUSION Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. SIGNIFICANCE Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.
Collapse
|
36
|
Khan JM, Rogers T, Schenke WH, Greenbaum AB, Babaliaros VC, Paone G, Ramasawmy R, Chen MY, Herzka DA, Lederman RJ. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve. Catheter Cardiovasc Interv 2018; 92:E175-E184. [PMID: 29405564 PMCID: PMC6078835 DOI: 10.1002/ccd.27531] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Revised: 01/15/2018] [Accepted: 01/15/2018] [Indexed: 11/07/2022]
Abstract
OBJECTIVES Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. BACKGROUND Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. METHODS Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. RESULTS Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm2 to 3.8 ± 1.5 cm2 (naïve) and 13.1 ± 1.5 cm2 to 6.2 ± 1.0 cm2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P < .01) using this strategy compared to single puncture techniques used to anchor current investigational devices. Serious complications were related to apical access. CONCLUSIONS PASTA reduces annular dimensions and tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology.
Collapse
|
37
|
Campbell-Washburn AE, Rogers T, Stine AM, Khan JM, Ramasawmy R, Schenke WH, McGuirt DR, Mazal JR, Grant LP, Grant EK, Herzka DA, Lederman RJ. Right heart catheterization using metallic guidewires and low SAR cardiovascular magnetic resonance fluoroscopy at 1.5 Tesla: first in human experience. J Cardiovasc Magn Reson 2018; 20:41. [PMID: 29925397 PMCID: PMC6011242 DOI: 10.1186/s12968-018-0458-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 05/10/2018] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. METHODS The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. RESULTS Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. CONCLUSIONS Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. TRIAL REGISTRATION Clinicaltrials.gov NCT03152773 , registered May 15, 2017.
Collapse
|
38
|
Walker-Samuel S, Roberts TA, Ramasawmy R, Burrell JS, Johnson SP, Siow BM, Richardson S, Gonçalves MR, Pendse D, Robinson SP, Pedley RB, Lythgoe MF. Investigating Low-Velocity Fluid Flow in Tumors with Convection-MRI. Cancer Res 2018; 78:1859-1872. [PMID: 29317434 PMCID: PMC6298581 DOI: 10.1158/0008-5472.can-17-1546] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/18/2017] [Accepted: 01/05/2018] [Indexed: 02/06/2023]
Abstract
Several distinct fluid flow phenomena occur in solid tumors, including intravascular blood flow and interstitial convection. Interstitial fluid pressure is often raised in solid tumors, which can limit drug delivery. To probe low-velocity flow in tumors resulting from raised interstitial fluid pressure, we developed a novel MRI technique named convection-MRI, which uses a phase-contrast acquisition with a dual-inversion vascular nulling preparation to separate intra- and extravascular flow. Here, we report the results of experiments in flow phantoms, numerical simulations, and tumor xenograft models to investigate the technical feasibility of convection-MRI. We observed a significant correlation between estimates of effective fluid pressure from convection-MRI with gold-standard, invasive measurements of interstitial fluid pressure in mouse models of human colorectal carcinoma. Our results show how convection-MRI can provide insights into the growth and responsiveness to vascular-targeting therapy in colorectal cancers.Significance: A noninvasive method for measuring low-velocity fluid flow caused by raised fluid pressure can be used to assess changes caused by therapy. Cancer Res; 78(7); 1859-72. ©2018 AACR.
Collapse
|
39
|
Muralitharan S, Ramasawmy R, Nagel L, Krishnamoorthy R, Romana M. Thrombosis-associated Gene Variants in Sickle Cell Anemia. Thromb Haemost 2017. [DOI: 10.1055/s-0037-1613007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
40
|
Rogers T, Ratnayaka K, Khan JM, Stine A, Schenke WH, Grant LP, Mazal JR, Grant EK, Campbell-Washburn A, Hansen MS, Ramasawmy R, Herzka DA, Xue H, Kellman P, Faranesh AZ, Lederman RJ. CMR fluoroscopy right heart catheterization for cardiac output and pulmonary vascular resistance: results in 102 patients. J Cardiovasc Magn Reson 2017; 19:54. [PMID: 28750642 PMCID: PMC5530573 DOI: 10.1186/s12968-017-0366-2] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Accepted: 06/21/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. METHODS One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RESULTS RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement -38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was -0.02 WU.m2 with limits of agreement -2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CONCLUSIONS CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. TRIAL REGISTRATION Clinicaltrials.gov NCT01287026 , registered January 25, 2011.
Collapse
|
41
|
Gonçalves MR, Johnson SP, Ramasawmy R, Lythgoe MF, Pedley RB, Walker-Samuel S. The effect of imatinib therapy on tumour cycling hypoxia, tissue oxygenation and vascular reactivity. Wellcome Open Res 2017. [DOI: 10.12688/wellcomeopenres.11715.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Background: Several biomedical imaging techniques have recently been developed to probe hypoxia in tumours, including oxygen-enhanced (OE) and blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI). These techniques have strong potential for measuring both chronic and transient (cycling) changes in hypoxia, and to assess response to vascular-targeting therapies in the clinic. Methods: In this study, we investigated the use of BOLD and OE-MRI to assess changes in cycling hypoxia, tissue oxygenation and vascular reactivity to hyperoxic gas challenges, in mouse models of colorectal therapy, following treatment with the PDGF-receptor inhibitor, imatinib mesylate (Glivec). Results: Whilst no changes were observed in imaging biomarkers of cycling hypoxia (from BOLD) or chronic hypoxia (from OE-MRI), the BOLD response to carbogen-breathing became significantly more positive in some tumour regions and more negative in other regions, thereby increasing overall heterogeneity. Conclusions: Imatinib did not affect the magnitude of cycling hypoxia or OE-MRI signal, but increased the heterogeneity of the spatial distribution of BOLD MRI changes in response to gas challenges.
Collapse
|
42
|
Gonçalves MR, Peter Johnson S, Ramasawmy R, Barbara Pedley R, Lythgoe MF, Walker-Samuel S. Decomposition of spontaneous fluctuations in tumour oxygenation using BOLD MRI and independent component analysis. Br J Cancer 2016; 114:e13. [PMID: 27228297 PMCID: PMC4984470 DOI: 10.1038/bjc.2016.140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
43
|
Ramasawmy R, Johnson SP, Roberts TA, Stuckey DJ, David AL, Pedley RB, Lythgoe MF, Siow B, Walker-Samuel S. Monitoring the Growth of an Orthotopic Tumour Xenograft Model: Multi-Modal Imaging Assessment with Benchtop MRI (1T), High-Field MRI (9.4T), Ultrasound and Bioluminescence. PLoS One 2016; 11:e0156162. [PMID: 27223614 PMCID: PMC4880291 DOI: 10.1371/journal.pone.0156162] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Accepted: 05/10/2016] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Research using orthotopic and transgenic models of cancer requires imaging methods to non-invasively quantify tumour burden. As the choice of appropriate imaging modality is wide-ranging, this study aimed to compare low-field (1T) magnetic resonance imaging (MRI), a novel and relatively low-cost system, against established preclinical techniques: bioluminescence imaging (BLI), ultrasound imaging (US), and high-field (9.4T) MRI. METHODS A model of colorectal metastasis to the liver was established in eight mice, which were imaged with each modality over four weeks post-implantation. Tumour burden was assessed from manually segmented regions. RESULTS All four imaging systems provided sufficient contrast to detect tumours in all of the mice after two weeks. No significant difference was detected between tumour doubling times estimated by low-field MRI, ultrasound imaging or high-field MRI. A strong correlation was measured between high-field MRI estimates of tumour burden and all the other modalities (p < 0.001, Pearson). CONCLUSION These results suggest that both low-field MRI and ultrasound imaging are accurate modalities for characterising the growth of preclinical tumour models.
Collapse
|
44
|
Johnson SP, Ramasawmy R, Campbell-Washburn AE, Wells JA, Robson M, Rajkumar V, Lythgoe MF, Pedley RB, Walker-Samuel S. Acute changes in liver tumour perfusion measured non-invasively with arterial spin labelling. Br J Cancer 2016; 114:897-904. [PMID: 27031853 PMCID: PMC4984798 DOI: 10.1038/bjc.2016.51] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 01/26/2016] [Accepted: 02/04/2016] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Non-invasive measures of tumour vascular perfusion are desirable, in order to assess response to vascular targeting (or modifying) therapies. In this study, hepatic arterial spin labelling (ASL) magnetic resonance imaging (MRI) was investigated to measure acute changes in perfusion of colorectal cancer in the liver, in response to vascular disruption therapy with OXi4503. METHODS SW1222 and LS174T tumours were established in the liver of MF1 nu/nu mice via intrasplenic injection. Perfusion and R2(*) MRI measurements were acquired with an Agilent 9.4T horizontal bore scanner, before and at 90 min after 40 mg kg(-1) OXi4503. RESULTS A significant decrease in SW1222 tumour perfusion was observed (-43±33%, P<0.005). LS174T tumours had a significantly lower baseline level of perfusion. Intrinsic susceptibility MRI showed a significant increase in R2(*) in LS174T tumours (28±25%, P<0.05). An association was found between the change in tumour perfusion and the proximity to large vessels, with pre-treatment blood flow predictive of subsequent response. Histological evaluation confirmed the onset of necrosis and evidence of heterogeneous response between tumour deposits. CONCLUSIONS Hepatic ASL-MRI can detect acute response to targeted tumour vascular disruption entirely non-invasively. Hepatic ASL of liver tumours has potential for use in a clinical setting.
Collapse
|
45
|
Garrido MDS, Bührer-Sékula S, Souza AB, de Oliveira GP, Antunes IA, Mendes JM, Saraceni V, Martinez-Espinosa FE, Ramasawmy R. Multidrug-resistant tuberculosis in the Amazonas State, Brazil, 2000-2011. Int J Tuberc Lung Dis 2016; 19:531-6. [PMID: 25868020 DOI: 10.5588/ijtld.14.0291] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
SETTINGS Amazonas is facing increasing challenges in tuberculosis (TB) control, with nearly 3000 cases per year, and multidrug-resistant TB (MDR-TB) may jeopardise the TB control programme. OBJECTIVE To assess the number of MDR-TB cases in the Amazonas and to improve estimates of the burden of TB. DESIGNS The Brazilian National Mandatory Disease Reporting System (SINAN) and the Brazilian Epidemiological Surveillance System of Multidrug Resistance (TBMR) were searched for MDR-TB cases in the State of Amazonas from 2000 to 2011. RESULTS Eighty-one MDR-TB cases were notified. The rates of primary MDR-TB, initial MDR-TB during the first treatment regimen and acquired MDR-TB were respectively 3.8%, 13.7% and 82.7%; 26.9% of previously treated patients had ⩾ 4 treatment cycles. The MDR-TB cases reported 263 contacts, only 35.0% of whom were examined. The cure and death rates among the 81 patients with MDR-TB were respectively 45.7% and 25.9%. CONCLUSIONS The number of MDR-TB cases seems incompatible with the high TB prevalence in the Amazonas. Most patients were unaware of contact with TB patients. TB is endemic in the Amazonas. This highlights the need for improving resistance investigation among all TB cases.
Collapse
|
46
|
Gonçalves MR, Johnson SP, Ramasawmy R, Pedley RB, Lythgoe MF, Walker-Samuel S. Decomposition of spontaneous fluctuations in tumour oxygenation using BOLD MRI and independent component analysis. Br J Cancer 2015; 113:1168-77. [PMID: 26484634 PMCID: PMC4647875 DOI: 10.1038/bjc.2015.270] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 05/26/2015] [Accepted: 06/29/2015] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Solid tumours can undergo cycles of hypoxia, followed by reoxygenation, which can have significant implications for the success of anticancer therapies. A need therefore exists to develop methods to aid its detection and to further characterise its biological basis. We present here a novel method for decomposing systemic and tumour-specific contributions to fluctuations in tumour deoxyhaemoglobin concentration, based on magnetic resonance imaging measurements. METHODS Fluctuations in deoxyhaemoglobin concentration in two tumour xenograft models of colorectal carcinoma were decomposed into distinct contributions using independent component analysis. These components were then correlated with systemic pulse oximetry measurements to assess the influence of systemic variations in blood oxygenation in tumours, compared with those that arise within the tumour itself (tumour-specific). Immunohistochemical staining was used to assess the physiological basis of each source of fluctuation. RESULTS Systemic fluctuations in blood oxygenation were found to contribute to cycling hypoxia in tumours, but tumour-specific fluctuations were also evident. Moreover, the size of the tumours was found to influence the degree of systemic, but not tumour-specific, oscillations. The degree of vessel maturation was related to the amplitude of tumour-specific, but not systemic, oscillations. CONCLUSIONS Our results provide further insights into the complexity of spontaneous fluctuations in tumour oxygenation and its relationship with tumour pathophysiology. These observations could be used to develop improved drug delivery strategies.
Collapse
|
47
|
de Araujo FJ, Mesquita TG, da Silva LDO, de Almeida SA, de S Vital W, Chrusciak-Talhari A, de O Guerra JA, Talhari S, Ramasawmy R. Functional variations in MBL2 gene are associated with cutaneous leishmaniasis in the Amazonas state of Brazil. Genes Immun 2015; 16:284-8. [PMID: 25764115 DOI: 10.1038/gene.2015.6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 12/19/2014] [Accepted: 01/05/2015] [Indexed: 01/01/2023]
Abstract
Functional variations in the mannose-binding lectin (MBL2) gene causing low levels of serum MBL are associated with susceptibility to numerous infectious diseases. We investigated whether there is genetic association of MBL2 variant alleles with cutaneous leishmaniasis (CL) caused by Leishmania guyanensis. We used PCR-restriction fragment length polymorphism to genotype six MBL2 variants, three in the promoter region and three in the exon 1. An association was noted between the single nucleotide polymorphism -221X/Y of the MBL2 gene and CL (P=2.9 × 10(-6); odds ratio (OR)=1.9 (1.4-2.5) consistent with the hypothesis that the -221X allele confers high risk to development of CL among L. guyanensis-infected individuals. Furthermore, L. guyanensis-infected individuals bearing the codon 57 allele C had a higher risk of developing CL (P=5 × 10(-5); OR=1.9 (1.4-2.6)). The low MBL expressor haplotype LXPB was also associated to CL (P=6 × 10(-4)). This study raises the possibility that functional polymorphisms in MBL2 gene play a role in clinical outcome of Leishmania infection.
Collapse
|
48
|
Ramasawmy R, Campbell-Washburn AE, Wells JA, Johnson SP, Pedley RB, Walker-Samuel S, Lythgoe MF. Hepatic arterial spin labelling MRI: an initial evaluation in mice. NMR IN BIOMEDICINE 2015; 28:272-80. [PMID: 25522098 PMCID: PMC4670473 DOI: 10.1002/nbm.3251] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 10/09/2014] [Accepted: 11/26/2014] [Indexed: 05/20/2023]
Abstract
The development of strategies to combat hepatic disease and augment tissue regeneration has created a need for methods to assess regional liver function. Liver perfusion imaging has the potential to fulfil this need, across a range of hepatic diseases, alongside the assessment of therapeutic response. In this study, the feasibility of hepatic arterial spin labelling (HASL) was assessed for the first time in mice at 9.4 T, its variability and repeatability were evaluated, and it was applied to a model of colorectal liver metastasis. Data were acquired using flow-sensitive alternating inversion recovery-arterial spin labelling (FAIR-ASL) with a Look-Locker readout, and analysed using retrospective respiratory gating and a T1 -based quantification. This study shows that preclinical HASL is feasible and exhibits good repeatability and reproducibility. Mean estimated liver perfusion was 2.2 ± 0.8 mL/g/min (mean ± standard error, n = 10), which agrees well with previous measurements using invasive approaches. Estimates of the variation gave a within-session coefficient of variation (CVWS) of 7%, a between-session coefficient of variation (CVBS) of 9% and a between-animal coefficient of variation (CVA) of 15%. The within-session Bland-Altman repeatability coefficient (RCWS) was 18% and the between-session repeatability coefficient (RCBS) was 29%. Finally, the HASL method was applied to a mouse model of liver metastasis, in which significantly lower mean perfusion (1.1 ± 0.5 mL/g/min, n = 6) was measured within the tumours, as seen by fluorescence histology. These data indicate that precise and accurate liver perfusion estimates can be achieved using ASL techniques, and provide a platform for future studies investigating hepatic perfusion in mouse models of disease.
Collapse
|
49
|
Silva GAV, Ramasawmy R, Boechat AL, Morais AC, Carvalho BKS, Sousa KBA, Souza VC, Cunha MGS, Barletta-Naveca RH, Santos MP, Naveca FG. Association of TNF -1031 C/C as a potential protection marker for leprosy development in Amazonas state patients, Brazil. Hum Immunol 2015; 76:137-41. [PMID: 25636570 DOI: 10.1016/j.humimm.2015.01.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2014] [Revised: 12/26/2014] [Accepted: 01/14/2015] [Indexed: 12/30/2022]
Abstract
Polymorphisms present in the TNF promoter region has shown to influence the gene transcription. Leprosy displays different clinical manifestations according to the immune responses of the individual infected with Mycobacterium leprae. In this study, we evaluated the single nucleotide polymorphisms (SNPs) -238 G/A (rs361525), -308 G/A (rs1800629), -857 C/T (rs1799724), -863 A/C (rs1800630) and -1031 T/C (rs1799964) in the promoter region of the TNF to see whether these SNPs influence host-susceptibility to leprosy and the different clinical manifestation. Nucleotide sequencing was performed with DNA samples from 108 leprosy patients and 253 control subjects. An association between -1031 C/C genotype and protection from leprosy was observed when leprosy patients were compared to controls (OR 0.11; 95% CI=0.01-0.82; p=0.012). The -857 C/T genotype may be associated with susceptibility to leprosy (OR=1.81; 95% CI=1.09-3.00; p=0.028). Similar genotype and allele frequencies for the SNPs -308 G/A and -238 G/A were observed between leprosy patients and control subjects. Altogether, TNF polymorphisms in the promoter region may be predictive of leprosy outcome.
Collapse
|
50
|
da Silva Garrido M, Ramasawmy R, Perez-Porcuna TM, Zaranza E, Chrusciak Talhari A, Martinez-Espinosa FE, Bührer-Sékula S. Primary drug resistance among pulmonary treatment-naïve tuberculosis patients in Amazonas State, Brazil. Int J Tuberc Lung Dis 2015; 18:559-63. [PMID: 24903793 DOI: 10.5588/ijtld.13.0191] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Multidrug-resistant tuberculosis (MDR-TB) is the main indicator of previous treatment in tuberculosis (TB) patients. MDR-TB among treatment-naïve patients indicates infection with drug-resistant Mycobacterium tuberculosis strains, and such cases are considered primary drug-resistant cases. OBJECTIVE To estimate the prevalence of drug resistance in pulmonary TB (PTB) treatment-naïve patients and to identify the socio-demographic and clinical characteristics of the resistant population. METHODS A total of 205 treatment-naïve PTB patients from Manaus, Amazonas State, Brazil, were enrolled. Drug susceptibility testing (DST) was performed on all positive mycobacterial cultures using the 1% proportion method. RESULTS Positive M. tuberculosis cultures were obtained from only 175 patients for DST. The prevalence of primary MDR-TB was 1.7% (3/175); 14.3% (25/175) of the cultures presented resistance to at least one of the drugs. Resistance to streptomycin, isoniazid, rifampicin and ethambutol was respectively 8.6%, 6.9%, 3.4% and 2.3%. An association between TB patients with resistance to more than one drug and known previous household contact with a TB patient was observed (P= 0.008, OR 6.7, 95%CI 1.2-67.3). CONCLUSIONS Although the prevalence of primary MDR-TB currently is relatively low, it may become a major public health problem if tailored treatment is not provided, as resistance to more than one drug is significantly associated with household contact.
Collapse
|