51
|
de Andrade F, Griebenow R, Costello RW, Guenova M, Schaefer R, Chalmers JD, Tichelli A, Raguz D, Stein J. The future of accreditation of continuing medical education (CME)-continuing professional development (CPD) in Europe: harmonisation through dialogue and consensus. J Eur CME 2018; 7:1506202. [PMID: 30206501 PMCID: PMC6129779 DOI: 10.1080/21614083.2018.1506202] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Accepted: 07/23/2018] [Indexed: 11/01/2022] Open
Abstract
In Europe, there are currently some 30 different jurisdictions and no overarching legislation regarding CME-CPD accreditation, since legislative competency related to national health-care systems lies with national authorities. Thus, public demonstration of professional agreement regarding the principles, rules and practice of CME-CPD as well as its accreditation is a highly desirable professional and political objective in Europe, where free movement and freedom to offer professional (medical) services is a key feature of the EU vision of the single market. The newly formed association of independent European accreditors, Continuing Medical Education - European Accreditors (CME-EA) is committed to offering a platform for dialogue between individuals and organisations involved in definition of professional codes in general, and accreditation of CME-CPD in particular on the national level. The aim is to reach a European consensus on principles and rules applied in planning and delivery of CME-CPD. This includes consensus on constituent characteristics of accreditors as well as principles and practice of accreditation.
Collapse
|
52
|
Cushen B, Sulaiman I, Greene G, MacHale E, Mokoka M, Reilly RB, Bennett K, Doyle F, van Boven JFM, Costello RW. The Clinical Impact of Different Adherence Behaviors in Patients with Severe Chronic Obstructive Pulmonary Disease. Am J Respir Crit Care Med 2018; 197:1630-1633. [DOI: 10.1164/rccm.201712-2469le] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
53
|
Greene G, Costello RW, Cushen B, Sulaiman I, Mac Hale E, Conroy RM, Doyle F. A novel statistical method for assessing effective adherence to medication and calculating optimal drug dosages. PLoS One 2018; 13:e0195663. [PMID: 29677197 PMCID: PMC5909911 DOI: 10.1371/journal.pone.0195663] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Accepted: 03/27/2018] [Indexed: 12/29/2022] Open
Abstract
OBJECTIVE We derive a novel model-based metric for effective adherence to medication, and validate it using data from the INhaler Compliance Assessment device (INCATM). This technique employs dose timing data to estimate the threshold drug concentration needed to maintain optimal health. METHODS The parameters of the model are optimised against patient outcome data using maximum likelihood methods. The model is fitted and validated by secondary analysis of two independent datasets from two remote-monitoring studies of adherence, conducted through clinical research centres of 5 Irish hospitals. Training data came from a cohort of asthma patients (~ 47,000 samples from 218 patients). Validation data is from a cohort of 204 patients with COPD recorded between 2014 and 2016. RESULTS The time above threshold measure is strongly predictive of adverse events (exacerbations) in COPD patients (Odds Ratio of exacerbation = 0.52 per SD increase in adherence, 95% Confidence Interval [0.34-0.79]). This compares well with the best known previous method, the Area Under the dose-time Curve (AUC) (Odds Ratio = 0.69, 95% Confidence Interval [0.48-0.99]). In addition, the fitted value of the dose threshold (0.56 of prescribed dosage) suggests that prescribed doses may be unnecessarily high given good adherence. CONCLUSIONS The resulting metric accounts for missed doses, dose-timing errors, and errors in inhaler technique, and provides enhanced predictive validity in comparison to previously used measures. In addition, the method allows us to estimate the correct dosage required to achieve the effect of the medication using the patients' own adherence data and outcomes. The adherence score does depend not on sex or other demographic factors suggesting that effective adherence is driven by individual behavioural factors.
Collapse
|
54
|
Miravitlles M, Sliwinski P, Rhee CK, Costello RW, Carter V, Tan J, Lapperre TS, Alcazar B, Gouder C, Esquinas C, García-Rivero JL, Kemppinen A, Tee A, Roman-Rodríguez M, Soler-Cataluña JJ, Price DB. Evaluation of criteria for clinical control in a prospective, international, multicenter study of patients with COPD. Respir Med 2018; 136:8-14. [DOI: 10.1016/j.rmed.2018.01.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Revised: 01/11/2018] [Accepted: 01/29/2018] [Indexed: 01/31/2023]
|
55
|
Taylor TE, Zigel Y, Egan C, Hughes F, Costello RW, Reilly RB. Objective Assessment of Patient Inhaler User Technique Using an Audio-Based Classification Approach. Sci Rep 2018; 8:2164. [PMID: 29391489 PMCID: PMC5794789 DOI: 10.1038/s41598-018-20523-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 01/16/2018] [Indexed: 12/29/2022] Open
Abstract
Many patients make critical user technique errors when using pressurised metered dose inhalers (pMDIs) which reduce the clinical efficacy of respiratory medication. Such critical errors include poor actuation coordination (poor timing of medication release during inhalation) and inhaling too fast (peak inspiratory flow rate over 90 L/min). Here, we present a novel audio-based method that objectively assesses patient pMDI user technique. The Inhaler Compliance Assessment device was employed to record inhaler audio signals from 62 respiratory patients as they used a pMDI with an In-Check Flo-Tone device attached to the inhaler mouthpiece. Using a quadratic discriminant analysis approach, the audio-based method generated a total frame-by-frame accuracy of 88.2% in classifying sound events (actuation, inhalation and exhalation). The audio-based method estimated the peak inspiratory flow rate and volume of inhalations with an accuracy of 88.2% and 83.94% respectively. It was detected that 89% of patients made at least one critical user technique error even after tuition from an expert clinical reviewer. This method provides a more clinically accurate assessment of patient inhaler user technique than standard checklist methods.
Collapse
|
56
|
Taylor TE, Lacalle Muls H, Costello RW, Reilly RB. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence. PLoS One 2018; 13:e0191330. [PMID: 29346430 PMCID: PMC5773205 DOI: 10.1371/journal.pone.0191330] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 01/03/2018] [Indexed: 01/18/2023] Open
Abstract
Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be clinically beneficial for inhaler technique training and the remote monitoring of patient adherence.
Collapse
|
57
|
Sulaiman I, Greene G, MacHale E, Seheult J, Mokoka M, D'Arcy S, Taylor T, Murphy DM, Hunt E, Lane SJ, Diette GB, FitzGerald JM, Boland F, Sartini Bhreathnach A, Cushen B, Reilly RB, Doyle F, Costello RW. A randomised clinical trial of feedback on inhaler adherence and technique in patients with severe uncontrolled asthma. Eur Respir J 2018; 51:51/1/1701126. [PMID: 29301919 DOI: 10.1183/13993003.01126-2017] [Citation(s) in RCA: 126] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Accepted: 09/29/2017] [Indexed: 11/05/2022]
Abstract
In severe asthma, poor control could reflect issues of medication adherence or inhaler technique, or that the condition is refractory. This study aimed to determine if an intervention with (bio)feedback on the features of inhaler use would identify refractory asthma and enhance inhaler technique and adherence.Patients with severe uncontrolled asthma were subjected to a stratified-by-site random block design. The intensive education group received repeated training in inhaler use, adherence and disease management. The intervention group received the same intervention, enhanced by (bio)feedback-guided training. The primary outcome was rate of actual inhaler adherence. Secondary outcomes included a pre-defined assessment of clinical outcome. Outcome assessors were blinded to group allocation. Data were analysed on an intention-to-treat and per-protocol basis.The mean rate of adherence during the third month in the (bio)feedback group (n=111) was higher than that in the enhanced education group (intention-to-treat, n=107; 73% versus 63%; 95% CI 2.8%-17.6%; p=0.02). By the end of the study, asthma was either stable or improved in 54 patients (38%); uncontrolled, but poorly adherent in 52 (35%); and uncontrolled, but adherent in 40 (27%).Repeated feedback significantly improved inhaler adherence. After a programme of adherence and inhaler technique assessment, only 40 patients (27%) were refractory and adherent, and might therefore need add-on therapy.
Collapse
|
58
|
Hunt E, Flynn D, MacHale E, Costello RW, Murphy DM. Reduction in exhaled nitric oxide tracks improved patient inhaler compliance in difficult asthma-a case study. J Asthma 2017; 55:1373-1375. [PMID: 29278953 DOI: 10.1080/02770903.2017.1414237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
INTRODUCTION Exhaled nitric oxide is believed be a useful surrogate for airways inflammation while non-adherence with therapy is known to be associated with worsening of asthma control. CASE We present the case of a 49-year-old female with steroid-dependent asthma and an exacerbation rate of >20/year. She was enrolled in a 3-month-long prospective study using a validated diagnostic inhaler device that provided objective evidence of inhaler compliance. Fractional exhaled nitric oxide (FeNO), peak expiratory flow rates, asthma control questionnaires were measured throughout the study period. Peripheral eosinophil count was obtained prior to the study, during the study, and immediately afterwards. RESULTS Improvement in compliance at the end of the study led to significant improvements in lung function peak expiratory flow rate (PEFR), and objective scores of asthma. There was an observed improvement in PEFR after 4 weeks, with an associated decrease in FeNO from 92 to 9 ppb that plateaued over the remainder of the study. Her eosinophil count was 0.79 × 109/litre prior to starting in the study, 0.37 × 109/litre after 2 months, and 0.1 × 109/litre at the end of the study. CONCLUSION We believe that this is the first case study to objectively prove that improvements in compliance can lead to dramatic reductions in the overall inflammatory airway response and in particular that improvements in patient compliance are mirrored by marked reduction in FeNO levels. These changes occurred in tandem with an observed clinical improvement in our patient.
Collapse
|
59
|
Sulaiman I, Seheult J, MacHale E, D'Arcy S, Boland F, McCrory K, Casey J, Bury G, Al-Alawi M, O'Dwyer S, Ryder SA, Reilly RB, Costello RW. Irregular and Ineffective: A Quantitative Observational Study of the Time and Technique of Inhaler Use. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2017; 4:900-909.e2. [PMID: 27587321 DOI: 10.1016/j.jaip.2016.07.009] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 07/19/2016] [Accepted: 07/20/2016] [Indexed: 11/20/2022]
Abstract
BACKGROUND Cross-sectional observational studies suggest that between 50% and 60% of patients misuse a dry powder inhaler, whereas studies with electronic monitors indicate that patients sometimes overuse/underuse their inhalers. It is not known what impact errors and erratic use have on inhaler adherence. OBJECTIVES The purpose of this study was to longitudinally quantify when and how patients adhered to a twice-daily preventer treatment by using a novel acoustic recording device attached to an inhaler (INhaler Compliance Assessment). METHODS Patients with a history of asthma or chronic obstructive pulmonary disease (n = 123) from primary care and community pharmacies were given an INhaler Compliance Assessment-adapted inhaler for 1 month. Analysis of the audio files provided quantitative information on time and technique of inhaler use. RESULTS Data were available for 103 patients. Twenty-one patients (20%) used their inhaler in the correct manner at the correct interval. There were 5045 audio files with attempted inhalations, of which 1204 had technique errors (24%). Errors included inadequate flow (27%), drug priming without inhalation (19%), exhalation into the inhaler (18%), and multiple inhalations (25%). On average, participants made errors 20% of the time. Of 60 doses expected to be taken in a month per person, on average 49 doses (82%) were attempted and when errors were accounted for, the average number of actual doses taken was 34 doses (57%; P < .01) comparing attempted to actual doses. DISCUSSION These data highlight that ineffective and irregular inhaler use is common and when combined in a single calculation indicate that only 20% of participants used their inhaler correctly and on time.
Collapse
|
60
|
Costello RW, Foster JM, Grigg J, Eakin MN, Canonica W, Yunus F, Ryan D. The Seven Stages of Man: The Role of Developmental Stage on Medication Adherence in Respiratory Diseases. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2017; 4:813-20. [PMID: 27587315 DOI: 10.1016/j.jaip.2016.04.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Revised: 04/03/2016] [Accepted: 04/06/2016] [Indexed: 02/08/2023]
Abstract
The circumstances and drivers of the decision to initiate, implement, or persist with a medication differ for individuals at each developmental stage. For school-age children with asthma, the social environment of their family's cultural beliefs and the influence of peer networks and school policies are strong determinants of medication adherence. The stage of adolescence can be a particularly challenging time because there is a reduction in parental supervision of asthma management as the young person strives to become more autonomous. To illustrate the importance of such factors, adherence interventions in children and young adults with asthma have used peer-based supports and social supports, particularly social media platforms. In older patients, it is internal rather than external factors and age-related decline that pose challenges to medication adherence. Seniors face the challenges of polypharmacy, reduced social support, increased isolation, and loss of cognitive function. Strategies to promote adherence must be tailored to the developmental stage and respective behavioral determinants of the target group. This review considers the different attitudes toward medication and the different adherence behaviors in young and elderly patients with chronic respiratory conditions, specifically asthma and chronic obstructive pulmonary disease. Opportunities to intervene to optimize adherence are suggested.
Collapse
|
61
|
Taylor TE, Zigel Y, De Looze C, Sulaiman I, Costello RW, Reilly RB. Advances in Audio-Based Systems to Monitor Patient Adherence and Inhaler Drug Delivery. Chest 2017; 153:710-722. [PMID: 28887061 DOI: 10.1016/j.chest.2017.08.1162] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 08/11/2017] [Accepted: 08/28/2017] [Indexed: 11/28/2022] Open
Abstract
Hundreds of millions of people worldwide have asthma and COPD. Current medications to control these chronic respiratory diseases can be administered using inhaler devices, such as the pressurized metered dose inhaler and the dry powder inhaler. Provided that they are used as prescribed, inhalers can improve patient clinical outcomes and quality of life. Poor patient inhaler adherence (both time of use and user technique) is, however, a major clinical concern and is associated with poor disease control, increased hospital admissions, and increased mortality rates, particularly in low- and middle-income countries. There are currently limited methods available to health-care professionals to objectively and remotely monitor patient inhaler adherence. This review describes recent sensor-based technologies that use audio-based approaches that show promising opportunities for monitoring inhaler adherence in clinical practice. This review discusses how one form of sensor-based technology, audio-based monitoring systems, can provide clinically pertinent information regarding patient inhaler use over the course of treatment. Audio-based monitoring can provide health-care professionals with quantitative measurements of the drug delivery of inhalers, signifying a clear clinical advantage over other methods of assessment. Furthermore, objective audio-based adherence measures can improve the predictability of patient outcomes to treatment compared with current standard methods of adherence assessment used in clinical practice. Objective feedback on patient inhaler adherence can be used to personalize treatment to the patient, which may enhance precision medicine in the treatment of chronic respiratory diseases.
Collapse
|
62
|
McCarthy H, O'Donnell S, Costello RW, Humphreys H. Hospital Resource Utilisation by Patients with Community-Acquired Pneumonia. IRISH MEDICAL JOURNAL 2017; 110:613. [PMID: 29168995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Little data is available on the resource utilisation of patients admitted with Community-Acquired Pneumonia (CAP) in Ireland. A retrospective review of 50 randomly-selected patients admitted to Beaumont Hospital with CAP was undertaken. The mean length of stay of patients with CAP was 12 days (+/- 16 days). All patients were emergency admissions, all had a chest x-ray, a C-reactive protein blood test, and occupied a public bed at some point during admission. Common antimicrobial therapies were intravenous (IV) amoxicillin/clavulanic acid and oral clarithromycin; 60% received physiotherapy. The estimated mean cost of CAP per patient was €14,802.17. Costs arising from admission to hospital with CAP are substantial, but efforts can be undertaken to ensure that resources are used efficiently to improve patient care such as discharge planning and fewer in-hospital ward transfers.
Collapse
|
63
|
Sulaiman I, Seheult J, Sadasivuni N, MacHale E, Killane I, Giannoutsos S, Cushen B, Mokoka MC, Bhreathnach AS, Boland F, Reilly RB, Costello RW. The Impact of Common Inhaler Errors on Drug Delivery: Investigating Critical Errors with a Dry Powder Inhaler. J Aerosol Med Pulm Drug Deliv 2017; 30:247-255. [DOI: 10.1089/jamp.2016.1334] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
64
|
McCartan TA, Taylor TE, Sulaiman I, Costello RW, Reilly RB. Changes in inhaler inhalation acoustic features during induced bronchoconstriction: a pilot study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:3749-3752. [PMID: 28269105 DOI: 10.1109/embc.2016.7591543] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Asthma is a chronic respiratory disease affecting millions of people worldwide, and is consequently a major issue for global health. Exacerbations are acute events involving the worsening of asthma's primary respiratory symptoms and are a major cause of morbidity in asthma patients, largely due to the unpredictability of their onset. This study aimed to investigate the relationship between changes in acoustic features of inhaler inhalations and changes in forced expiratory volume in one second (FEV1) that occur during a simulated exacerbation, a bronchial challenge test (BCT). This is a clinical test that simulates an asthma exacerbation through the administration of a bronchoconstrictor agent. Eight patients indicated for a BCT were recruited for this study. Non-contact and tracheal microphones were employed to record Diskus™ inhaler inhalations throughout the course of a BCT. A spirometer was employed to measure inhaler peak inspiratory flow rate (PIFR). In patients responsive to the BCT (n=4), significant correlations between changes in FEV1 and acoustic features on both microphones existed, with fractal increment of Katz fractal dimension yielding the strongest correlation (R=0.58), and between FEV1 and PIFR (R=0.62). These findings suggest that inhaler inhalation acoustic features may assist in the early detection of exacerbations. Future research will determine whether this is the case in a larger cohort of patients with non-simulated exacerbations.
Collapse
|
65
|
Sulaiman I, Cushen B, Greene G, Seheult J, Seow D, Rawat F, MacHale E, Mokoka M, Moran CN, Sartini Bhreathnach A, MacHale P, Tappuni S, Deering B, Jackson M, McCarthy H, Mellon L, Doyle F, Boland F, Reilly RB, Costello RW. Objective Assessment of Adherence to Inhalers by Patients with Chronic Obstructive Pulmonary Disease. Am J Respir Crit Care Med 2017; 195:1333-1343. [PMID: 27409253 DOI: 10.1164/rccm.201604-0733oc] [Citation(s) in RCA: 136] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
RATIONALE Objective adherence to inhaled therapy by patients with chronic obstructive pulmonary disease (COPD) has not been reported. OBJECTIVES To objectively quantify adherence to preventer Diskus inhaler therapy by patients with COPD with an electronic audio recording device (INCA). METHODS This was a prospective observational study. On discharge from hospital patients were given a salmeterol/fluticasone inhaler with an INCA device attached. Analysis of this audio quantified the frequency and proficiency of inhaler use. MEASUREMENTS AND MAIN RESULTS Patients with COPD (n = 244) were recruited. The mean age was 71 years, mean FEV1 was 1.3 L, and 59% had evidence of mild/moderate cognitive impairment. By combining time of use, interval between doses, and critical technique errors, thus incorporating both intentional and unintentional nonadherence, a measure "actual adherence" was calculated. Mean actual adherence was 22.6% of that expected if the doses were taken correctly and on time. Six percent had an actual adherence greater than 80%. Hierarchical clustering found three equally sized well-separated clusters corresponding to distinct patterns. Cluster 1 (34%) had low inhaler use and high error rates. Cluster 2 (25%) had high inhaler use and high error rates. Cluster 3 (36%) had overall good adherence. Poor lung function and comorbidities were predictive of poor technique, whereas age and cognition with poor lung function distinguished those with poor adherence and frequent errors in technique. CONCLUSIONS These data may inform clinicians in understanding why a prescribed inhaler is not effective and to devise strategies to promote adherence in COPD.
Collapse
|
66
|
McCarthy H, Jackson M, Corcoran M, McElligott M, MacHale E, Sulaiman I, Cushen B, Costello RW, Humpreys H. Colonisation of Irish patients with chronic obstructive pulmonary disease by Streptococcus pneumoniae and analysis of the pneumococcal vaccine coverage: a non-interventional, observational, prospective cohort study. BMJ Open 2017; 7:e013944. [PMID: 28694340 PMCID: PMC5541633 DOI: 10.1136/bmjopen-2016-013944] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES To characterise the pattern of colonisation and serotypes of Streptococcus pneumoniae among patients with chronic obstructive pulmonary disease (COPD) who currently receive the 23-valent pneumococcal polysaccharide vaccine (PPV-23) according to vaccination status, use of antibiotics and steroids. To investigate the prevalence of PPV-23 and 13-valent pneumococcal conjugate vaccine (PCV-13) serotypes within the study cohort. DESIGN A non-interventional, observational, prospective cohort study with a 12 -month follow-up period inclusive of quarterly study visits. SETTING Beaumont Hospital and The Royal College of Surgeons in Ireland Clinical Research Centre, Dublin, Ireland. PARTICIPANTS Patients with an established diagnosis of COPD attending a tertiary medical centre. PRIMARY OUTCOME MEASURE Colonisation rate of S. pneumoniae in patients with COPD and characterisation of serotypes of S. pneumoniae with correlation to currently available pneumococcal vaccines. Sputum and oropharyngeal swab samples were collected for the isolation of S. pneumoniae. SECONDARY OUTCOME MEASURE Seasonality of colonisation of S. pneumoniae and its relationship with the incidence of exacerbations of COPD. RESULTS S. pneumoniae was detected in 16 of 417 samples, a colonisation incident rate of 3.8% and in 11 of 133 (8%) patients at least once during the study. The majority of S. pneumoniae isolates were identified in spring and were non-vaccine serotypes for either the PPV-23 or PCV-13 (63%). The colonisation incident rate of S. pneumoniae fluctuated over the four seasons with a peak of 6.6% in spring and the lowest rate of 2.2% occurring during winter. Antibiotic use was highest during periods of low colonisation. CONCLUSIONS There is seasonal variation in S. pneumoniae colonisation among patients with COPD which may reflect antibiotic use in autumn and winter. The predominance of non-vaccine types suggests that PCV-13 may have limited impact among patients with COPD in Ireland who currently receive PPV-23. TRIAL REGISTRATION NUMBER NCT02535546; post-results.
Collapse
|
67
|
Costello RW, Dima AL, Ryan D, McIvor RA, Boycott K, Chisholm A, Price D, Blakey JD. Effective deployment of technology-supported management of chronic respiratory conditions: a call for stakeholder engagement. Pragmat Obs Res 2017; 8:119-128. [PMID: 28740444 PMCID: PMC5505604 DOI: 10.2147/por.s132316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Background Healthcare systems are under increasing strain, predominantly due to chronic non-communicable diseases. Connected healthcare technologies are becoming ever more capable and their components cheaper. These innovations could facilitate both self-management and more efficient use of healthcare resources for common respiratory diseases such as asthma and chronic obstructive pulmonary disease. However, newer technologies can only facilitate major changes in practice, and cannot accomplish them in isolation. Focus of review There are now large numbers of devices and software offerings available. However, the potential of such technologies is not being realised due to limited engagement with the public, clinicians and providers, and a relative paucity of evidence describing elements of best practice in this complex and evolving environment. Indeed, there are clear examples of wasted resources and potential harm. We therefore call on interested parties to work collaboratively to begin to realize the potential benefits and reduce the risks of connected technologies through change in practice. We highlight key areas where such partnership can facilitate the effective and safe use of technology in chronic respiratory care: developing data standards and fostering inter-operability, making collaborative testing facilities available at scale for small to medium enterprises, developing and promoting new adaptive trial designs, developing robust health economic models, agreeing expedited approval pathways, and detailed planning of dissemination to use. Conclusion The increasing capability and availability of connected technologies in respiratory care offers great opportunities and significant risks. A co-ordinated collaborative approach is needed to realize these benefits at scale. Using newer technologies to revolutionize practice relies on widespread engagement and cannot be delivered by a minority of interested specialists. Failure to engage risks a costly and inefficient chapter in respiratory care.
Collapse
|
68
|
Mokoka MC, Lombard L, MacHale EM, Walsh J, Cushen B, Sulaiman I, Carthy DM, Boland F, Doyle F, Hunt E, Murphy DM, Faul J, Butler M, Hetherington K, Mark FitzGerald J, van Boven JFM, Heaney LG, Reilly RB, Costello RW. In patients with severe uncontrolled asthma, does knowledge of adherence and inhaler technique using electronic monitoring improve clinical decision making? A protocol for a randomised controlled trial. BMJ Open 2017; 7:e015367. [PMID: 28619778 PMCID: PMC5734350 DOI: 10.1136/bmjopen-2016-015367] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
INTRODUCTION Many patients with asthma remain poorly controlled despite the use of inhaled corticosteroids and long-acting beta agonists. Poor control may arise from inadequate adherence, incorrect inhaler technique or because the condition is refractory. Without having an objective assessment of adherence, clinicians may inadvertently add extra medication instead of addressing adherence. This study aims to assess if incorporating objectively recorded adherence from the Inhaler Compliance Assessment (INCA) device and lung function into clinical decision making provides more cost-effective prescribing and improves outcomes. METHODS AND ANALYSIS This prospective, randomised, multicentre study will compare the impact of using information on adherence to influence asthma treatment. Patients with severe uncontrolled asthma will be included. Data on adherence, inhaler technique and electronically recorded peak expiratory flow rate will be used to promote adherence and guide a clinical decision protocol to guide management in the active group. The control group will receive standard inhaler and adherence education. Medications will be adjusted using a protocol based on Global Initiativefor Asthma (GINA) recommendations. The primary outcome is the between-group difference in the proportion of patients who have refractory disease and are prescribed appropriate medications at the end of 32 weeks. A co-primary outcome is the difference between groups in the rate of adherence to salmeterol/fluticasone inhaler over the last 12 weeks. Secondary outcomes include changes in symptoms, lung function, type-2 cytokine biomarkers and clinical outcomes between both groups. Cost-effectiveness and cost-utility analyses of the INCA device intervention will be performed. The economic impact of a national implementation of the INCA-SUN programme will be evaluated. ETHICS AND DISSEMINATION The results of the study will be published as a manuscript in peer-reviewed journals. The study has been approved by the ethics committees in the five participating hospitals. TRIAL REGISTRATION NCT02307669; Pre-results.
Collapse
|
69
|
Stolz D, Griebenow R, Tichelli A, Ullmann AJ, Costello RW, Michalis L, Guenova M, Sutter S, De Andrade F, Schaefer R. Position paper on current aspects of sponsoring in accredited CME. J Eur CME 2017; 6:1312062. [PMID: 29644130 PMCID: PMC5843059 DOI: 10.1080/21614083.2017.1312062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Accepted: 03/15/2017] [Indexed: 10/30/2022] Open
Abstract
This position paper is the result of a collaborative approach of several European Specialty Accreditation Boards (ESABs) and, has been stimulated by their current experience in accreditation regarding roles and responsibilities assumed by sponsors of accredited continuing medical education (CME). The suggestions made in this paper aim to preserve the fundamental principle in CME accreditation that the physician in charge of the programme has sole responsibility for the selection of topics, speakers, content and format, as well as mode of presentation, and that sponsors will under no circumstances interfere with this principle. This is considered as a responsibility of an individual physician (or physicians), which cannot be delegated, even in part, to third parties. This responsibility has been extended to include all communication before and after the event. The paper also identifies undecided issues, about which ESABs are committed to elaborate proposals in the future.
Collapse
|
70
|
Moran C, Doyle F, Sulaiman I, Bennett K, Greene G, Molloy GJ, Reilly RB, Costello RW, Mellon L. The INCATM (Inhaler Compliance AssessmentTM): A comparison with established measures of adherence. Psychol Health 2017; 32:1266-1287. [DOI: 10.1080/08870446.2017.1290243] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
71
|
Mesquita R, Spina G, Pitta F, Donaire-Gonzalez D, Deering BM, Patel MS, Mitchell KE, Alison J, van Gestel AJ, Zogg S, Gagnon P, Abascal-Bolado B, Vagaggini B, Garcia-Aymerich J, Jenkins SC, Romme EA, Kon SS, Albert PS, Waschki B, Shrikrishna D, Singh SJ, Hopkinson NS, Miedinger D, Benzo RP, Maltais F, Paggiaro P, McKeough ZJ, Polkey MI, Hill K, Man WDC, Clarenbach CF, Hernandes NA, Savi D, Wootton S, Furlanetto KC, Cindy Ng LW, Vaes AW, Jenkins C, Eastwood PR, Jarreta D, Kirsten A, Brooks D, Hillman DR, Sant'Anna T, Meijer K, Dürr S, Rutten EP, Kohler M, Probst VS, Tal-Singer R, Gil EG, den Brinker AC, Leuppi JD, Calverley PM, Smeenk FW, Costello RW, Gramm M, Goldstein R, Groenen MT, Magnussen H, Wouters EF, ZuWallack RL, Amft O, Watz H, Spruit MA. Physical activity patterns and clusters in 1001 patients with COPD. Chron Respir Dis 2017; 14:256-269. [PMID: 28774199 PMCID: PMC5720232 DOI: 10.1177/1479972316687207] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
We described physical activity measures and hourly patterns in patients with chronic obstructive pulmonary disease (COPD) after stratification for generic and COPD-specific characteristics and, based on multiple physical activity measures, we identified clusters of patients. In total, 1001 patients with COPD (65% men; age, 67 years; forced expiratory volume in the first second [FEV1], 49% predicted) were studied cross-sectionally. Demographics, anthropometrics, lung function and clinical data were assessed. Daily physical activity measures and hourly patterns were analysed based on data from a multisensor armband. Principal component analysis (PCA) and cluster analysis were applied to physical activity measures to identify clusters. Age, body mass index (BMI), dyspnoea grade and ADO index (including age, dyspnoea and airflow obstruction) were associated with physical activity measures and hourly patterns. Five clusters were identified based on three PCA components, which accounted for 60% of variance of the data. Importantly, couch potatoes (i.e. the most inactive cluster) were characterised by higher BMI, lower FEV1, worse dyspnoea and higher ADO index compared to other clusters (p < 0.05 for all). Daily physical activity measures and hourly patterns are heterogeneous in COPD. Clusters of patients were identified solely based on physical activity data. These findings may be useful to develop interventions aiming to promote physical activity in COPD.
Collapse
|
72
|
Al Said A, Cushen B, Costello RW. Targeting patients with asthma for omalizumab therapy: choosing the right patient to get the best value for money. Ther Adv Chronic Dis 2017; 8:31-45. [PMID: 28348726 DOI: 10.1177/2040622317690494] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 12/22/2016] [Indexed: 11/15/2022] Open
Abstract
The asthma syndrome has many manifestations, termed phenotypes, that arise by specific cellular and molecular mechanisms, termed endotypes. Understanding an individual's asthma phenotype helps clinicians make rational therapeutic decisions while the understanding of endotypes has led to the development of specific precision medications. Allergic asthma is an example of an asthma phenotype and omalizumab, a monoclonal antibody that neutralizes serum immunoglobulin (Ig)E, is a specific targeted treatment which was developed as a result of an understanding of the endotype of allergic asthma. Omalizumab has been widely used in clinical practice in Europe for over a decade as an add-on therapy to treat patients who have severe refractory allergic asthma. Over this period, many centres have reported their experience with omalizumab as an add-on therapy in patients with severe asthma. These 'real world' clinical effectiveness studies have confirmed the benefits, cost-effectiveness and clinical utility of this medication. Combining the outcomes of both sources of research has yielded important insights that may benefit patients with severe asthma, clinicians who treat them, as well as the funding agencies that reimburse the cost of this medication. The purpose of this review is to describe how to identify and evaluate a patient with asthma for whom treatment with omalizumab may be of clinical and cost-effective benefit. The assessment and investigations used to confirm allergic asthma, the objective assessment of adherence to asthma therapy and the expected benefits of add-on omalizumab treatment are described.
Collapse
|
73
|
Spina G, Spruit MA, Alison J, Benzo RP, Calverley PMA, Clarenbach CF, Costello RW, Donaire-Gonzalez D, Dürr S, Garcia-Aymerich J, van Gestel AJR, Gramm M, Hernandes NA, Hill K, Hopkinson NS, Jarreta D, Kohler M, Kirsten AM, Leuppi JD, Magnussen H, Maltais F, Man WDC, McKeough ZJ, Mesquita R, Miedinger D, Pitta F, Singh SJ, Smeenk FWJM, Tal-Singer R, Vagaggini B, Waschki B, Watz H, Wouters EFM, Zogg S, den Brinker AC. Analysis of nocturnal actigraphic sleep measures in patients with COPD and their association with daytime physical activity. Thorax 2017; 72:694-701. [PMID: 28082529 DOI: 10.1136/thoraxjnl-2016-208900] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 11/15/2016] [Accepted: 12/07/2016] [Indexed: 12/30/2022]
Abstract
BACKGROUND Sleep disturbances are common in patients with chronic obstructive pulmonary disease (COPD) with a considerable negative impact on their quality of life. However, factors associated with measures of sleep in daily life have not been investigated before nor has the association between sleep and the ability to engage in physical activity on a day-to-day basis been studied. AIMS To provide insight into the relationship between actigraphic sleep measures and disease severity, exertional dyspnoea, gender and parts of the week; and to investigate the association between sleep measures and next day physical activity. METHODS Data were analysed from 932 patients with COPD (66% male, 66.4±8.3 years, FEV1% predicted=50.8±20.5). Participants had sleep and physical activity continuously monitored using a multisensor activity monitor for a median of 6 days. Linear mixed effects models were applied to investigate the factors associated with sleep impairment and the association between nocturnal sleep and patients' subsequent daytime physical activity. RESULTS Actigraphic estimates of sleep impairment were greater in patients with worse airflow limitation and worse exertional dyspnoea. Patients with better sleep measures (ie, non-fragmented sleep, sleeping bouts ≥225 min, sleep efficiency ≥91% and time spent awake after sleep onset <57 min) spent significantly more time in light (p<0.01) and moderate-to-vigorous physical activity (p<0.01). CONCLUSIONS There is a relationship between measures of sleep in patients with COPD and the amount of activity they undertake during the waking day. Identifying groups with specific sleep characteristics may be useful information when designing physical activity-enhancing interventions.
Collapse
|
74
|
Bosnic-Anticevich S, Chrystyn H, Costello RW, Dolovich MB, Fletcher MJ, Lavorini F, Rodríguez-Roisin R, Ryan D, Wan Yau Ming S, Price DB. The use of multiple respiratory inhalers requiring different inhalation techniques has an adverse effect on COPD outcomes. Int J Chron Obstruct Pulmon Dis 2016; 12:59-71. [PMID: 28053517 PMCID: PMC5191843 DOI: 10.2147/copd.s117196] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Patients with COPD may be prescribed multiple inhalers as part of their treatment regimen, which require different inhalation techniques. Previous literature has shown that the effectiveness of inhaled treatment can be adversely affected by incorrect inhaler technique. Prescribing a range of device types could worsen this problem, leading to poorer outcomes in COPD patients, but the impact is not yet known. AIMS To compare clinical outcomes of COPD patients who use devices requiring similar inhalation technique with those who use devices with mixed techniques. METHODS A matched cohort design was used, with 2 years of data from the Optimum Patient Care Research Database. Matching variables were established from a baseline year of follow-up data, and two cohorts were formed: a "similar-devices cohort" and a "mixed-devices cohort". COPD-related events were recorded during an outcome year of follow-up. The primary outcome measure was an incidence rate ratio (IRR) comparing the rate of exacerbations between study cohorts. A secondary outcome compared average daily use of short-acting beta agonist (SABA). RESULTS The final study sample contained 8,225 patients in each cohort (mean age 67 [SD, 10], 57% males, 37% current smokers). Patients in the similar-devices cohort had a lower rate of exacerbations compared with those in the mixed-devices cohort (adjusted IRR 0.82, 95% confidence interval [CI] 0.80-0.84) and were less likely to be in a higher-dose SABA group (adjusted proportional odds ratio 0.54, 95% CI 0.51-0.57). CONCLUSION COPD patients who were prescribed one or more additional inhaler devices requiring similar inhalation techniques to their previous device(s) showed better outcomes than those who were prescribed devices requiring different techniques.
Collapse
|
75
|
Mokoka MC, McDonnell MJ, Cushen B, Cormican S, Sulaiman I, Doyle F, Boland F, Costello RW. P152 Inhaled corticosteroid (ICS) and long acting beta-adrenoceptor agonist (LABA) therapy adherence reporting and monitoring in clinical trials of severe adult asthma drug treatments: a systematic review. Thorax 2016. [DOI: 10.1136/thoraxjnl-2016-209333.295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
76
|
Sulaiman I, Mokoka MC, MacHale E, Seheult J, Hughes C, Holmes M, D’arcy S, Taylor T, Rapcan V, Murphy D, Hunt E, Lane SJ, Sahadevan A, Crispino G, Diette GB, Sartini-Bhreathnach A, Cushen B, Killane I, Reilly RB, Costello RW. P208 Behavioural feed-back education intervention to enhance adherence in patients with severe uncontrolled asthma, a randomised clinical trial. Thorax 2016. [DOI: 10.1136/thoraxjnl-2016-209333.351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
77
|
Cushen B, Alsaid A, Abdulkareem A, Costello RW. P292 Pilot study to assess bronchodilator response during an acute exacerbation of copd using a vibrating mesh nebuliser versus jet nebuliser for bronchodilator delivery. Thorax 2016. [DOI: 10.1136/thoraxjnl-2016-209333.435] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
78
|
Hetherington KJ, Costello RW, Heaney LG. S2 Fractional exhaled nitric oxide (feno) suppression to identify non-adherence in difficult asthma. Thorax 2016. [DOI: 10.1136/thoraxjnl-2016-209333.8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
79
|
Taylor TE, De Looze C, MacHale P, Holmes MS, Sulaiman I, Costello RW, Reilly RB. Characterization of patient inhaler inhalation sounds using non-contact and tracheal microphones. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/5/055021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
80
|
Bennett G, Cushen B, Killane I, Maguire F, Costello RW, Reilly RB. 109INVESTIGATING GAIT AND COGNITION IN ELDERLY COPD PATIENTS HOSPITALISED WITH AN ACUTE EXACERBATION. Age Ageing 2016. [DOI: 10.1093/ageing/afw159.120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
81
|
Taylor TE, Holmes MS, Sulaiman I, Costello RW, Reilly RB. Influences of gender and anthropometric features on inspiratory inhaler acoustics and peak inspiratory flow rate. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:2227-30. [PMID: 26736734 DOI: 10.1109/embc.2015.7318834] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Inhalers are hand-held devices used to treat chronic respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD). Medication is delivered from an inhaler to the user through an inhalation maneuver. It is unclear whether gender and anthropometric features such as age, height, weight and body mass index (BMI) influence the acoustic properties of inspiratory inhaler sounds and peak inspiratory flow rate (PIFR) in inhalers. In this study, healthy male (n=9) and female (n=7) participants were asked to inhale at an inspiratory flow rate (IFR) of 60 L/min in four commonly used inhalers (Turbuhaler(™), Diskus(™), Ellipta(™) and Evohaler(™)). Ambient inspiratory sounds were recorded from the mouthpiece of each inhaler and over the trachea of each participant. Each participant's PIFR was also recorded for each of the four inhalers. Results showed that gender and anthropometric features have the potential to influence the spectral properties of ambient and tracheal inspiratory inhaler sounds. It was also observed that males achieved statistically significantly higher PIFRs in each inhaler in comparison to females (p<;0.05). Acoustic features were found to be significantly different across inhalers suggesting that acoustic features are modulated by the inhaler design and its internal resistance to airflow.
Collapse
|
82
|
Kayyali R, Savickas V, Spruit MA, Kaimakamis E, Siva R, Costello RW, Chang J, Pierscionek B, Davies N, Vaes AW, Paradiso R, Philip N, Perantoni E, D'Arcy S, Raptopoulos A, Nabhani-Gebara S. Qualitative investigation into a wearable system for chronic obstructive pulmonary disease: the stakeholders' perspective. BMJ Open 2016; 6:e011657. [PMID: 27580831 PMCID: PMC5013515 DOI: 10.1136/bmjopen-2016-011657] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES To ascertain the stakeholders' views and devise recommendations for further stages of the Wearable Sensing and Smart Cloud Computing for Integrated Care to Chronic Obstructive Pulmonary Disease (COPD) Patients with Co-morbidities (WELCOME) system development. This system aims to create a wearable vest to monitor physiological signals for patients concerned incorporating an inhaler adherence monitoring, weight, temperature, blood pressure and glucose metres, and a mobile health application for communication with healthcare professionals (HCPs). DESIGN A study of qualitative data derived from focus groups and semistructured interviews. SETTING 4 participating clinical sites in Greece, the UK, Ireland and the Netherlands. PARTICIPANTS Purposive sampling was used to recruit 32 patients with COPD with heart failure, diabetes, anxiety or depression, 27 informal carers and 23 HCPs from 4 European Union (EU) countries for focus groups and interviews. RESULTS Most patients and HCPs described the WELCOME system as 'brilliant and creative' and felt it gave a sense of safety. Both users and HCPs agreed that the duration and frequency of vest wear should be individualised as should the mobile application functions. The parameters and frequency of monitoring should be personalised using a multidisciplinary approach. A 'traffic light' alert system was proposed by HCPs for abnormal results. Patients were happy to take actions in response. CONCLUSIONS WELCOME stakeholders provided valuable views on the development of the system, which should take into account patient's individual comorbidities, circumstances and concerns. This will enable the development of the individualised system in each member state concerned.
Collapse
|
83
|
Lynn TM, Molloy EL, Masterson JC, Glynn SF, Costello RW, Avdalovic MV, Schelegle ES, Miller LA, Hyde DM, O'Dea S. SMAD Signaling in the Airways of Healthy Rhesus Macaques versus Rhesus Macaques with Asthma Highlights a Relationship Between Inflammation and Bone Morphogenetic Proteins. Am J Respir Cell Mol Biol 2016; 54:562-73. [PMID: 26414797 DOI: 10.1165/rcmb.2015-0210oc] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Bone morphogenetic protein (BMP) signaling is important for correct lung morphogenesis, and there is evidence of BMP signaling reactivation in lung diseases. However, little is known about BMP signaling patterns in healthy airway homeostasis and inflammatory airway disease and during epithelial repair. In this study, a rhesus macaque (Macaca mulatta) model of allergic airway disease was used to investigate BMP signaling throughout the airways in health, disease, and regeneration. Stereologic quantification of immunofluorescent images was used to determine the expression of BMP receptor (BMPR) Ia and phosphorylated SMAD (pSMAD) 1/5/8 in the airway epithelium. A pSMAD 1/5/8 expression gradient was found along the airways of healthy juvenile rhesus macaques (n = 3, P < 0.005). Membrane-localized BMPRIa expression was also present in the epithelium of the healthy animals. After exposure to house dust mite allergen and ozone, significant down-regulation of nuclear pSMAD 1/5/8 occurs in the epithelium. When the animals were provided with a recovery period in filtered air, proliferating cell nuclear antigen, pSMAD 1/5/8, and membrane-localized BMPRIa expression were significantly increased in the epithelium of conducting airways (P < 0.005). Furthermore, in the asthmatic airways, altered BMPRIa localization was evident. Because of the elevated eosinophil presence in these airways, we investigated the effect of eosinophil-derived proteins on BMPRIa trafficking in epithelial cells. Eosinophil-derived proteins (eosinophil-derived neurotoxin, eosinophil peroxidase, and major basic protein) induced transient nuclear translocation of membrane-bound BMPRIa. This work mapping SMAD signaling in the airways of nonhuman primates highlights a potential mechanistic relationship between inflammatory mediators and BMP signaling and provides evidence that basal expression of the BMP signaling pathway may be important for maintaining healthy airways.
Collapse
|
84
|
Cushen B, McCormack N, Hennigan K, Sulaiman I, Costello RW, Deering B. A pilot study to monitor changes in spirometry and lung volume, following an exacerbation of Chronic Obstructive Pulmonary Disease (COPD), as part of a supported discharge program. Respir Med 2016; 119:55-62. [PMID: 27692148 DOI: 10.1016/j.rmed.2016.08.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 08/16/2016] [Accepted: 08/21/2016] [Indexed: 11/25/2022]
Abstract
BACKGROUND One-third of patients with an exacerbation of Chronic Obstructive Pulmonary Disease(COPD) are re-hospitalised at 90 days. Exacerbation recovery is associated with reductions in lung hyperinflation and improvements in symptoms and physical activity. We assessed the feasibility of monitoring these clinical parameters in the home. We hypothesised that the degree of change in spirometry and lung volumes differs between those who had an uneventful recovery and those who experienced a further exacerbation. METHODS Hospitalised patients with an acute exacerbation of COPD referred for a supported discharge program participated in the study. Spirometry and Inspiratory Vital Capacity(IVC) were measured in the home at Days 1, 14 and 42 post-discharge. Patients also completed Medical Research Council(MRC), Borg and COPD Assessment Test(CAT) scores and were provided with a tri-axial accelerometer. Any new exacerbation events were recorded. RESULTS Sixty-five patients with 72 exacerbation episodes were recruited. Fifty percent experienced a second exacerbation. Adequate IVC measurements were achieved by 90%, while only 70% completed spirometry. Uneventful recovery was accompanied by significant improvements in physiological measurements at day14, improved symptom scores and step count, p < 0.05. Failure of MRC to improve was predictive of re-exacerbation(Area Under Receiver Operating Curve(AUROC) 0.6713) with improvements in FEV1≥100 ml(AUROC 0.6613) and mean daily step count ≥396 steps(AUROC 0.6381) predictive of recovery. CONCLUSION Monitoring the pattern of improvement in spirometry, lung volumes, symptoms and step count following a COPD exacerbation may help to identify patients at risk of re-exacerbation. It is feasible to carry out these assessments in the home as part of a supported discharge programme.
Collapse
|
85
|
Hennigan K, Conroy PJ, Walsh MT, Amin M, O'Kennedy R, Ramasamy P, Gleich GJ, Siddiqui Z, Glynn S, McCabe O, Mooney C, Harvey BJ, Costello RW, McBryan J. Eosinophil peroxidase activates cells by HER2 receptor engagement and β1-integrin clustering with downstream MAPK cell signaling. Clin Immunol 2016; 171:1-11. [PMID: 27519953 PMCID: PMC5070911 DOI: 10.1016/j.clim.2016.08.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 08/02/2016] [Accepted: 08/06/2016] [Indexed: 01/21/2023]
Abstract
Eosinophils account for 1–3% of peripheral blood leukocytes and accumulate at sites of allergic inflammation, where they play a pathogenic role. Studies have shown that treatment with mepolizumab (an anti-IL-5 monoclonal antibody) is beneficial to patients with severe eosinophilic asthma, however, the mechanism of precisely how eosinophils mediate these pathogenic effects is uncertain. Eosinophils contain several cationic granule proteins, including Eosinophil Peroxidase (EPO). The main significance of this work is the discovery of EPO as a novel ligand for the HER2 receptor. Following HER2 activation, EPO induces activation of FAK and subsequent activation of β1-integrin, via inside-out signaling. This complex results in downstream activation of ERK1/2 and a sustained up regulation of both MUC4 and the HER2 receptor. These data identify a receptor for one of the eosinophil granule proteins and demonstrate a potential explanation of the proliferative effects of eosinophils. Eosinophil peroxidase (EPO) is confirmed as a ligand for the HER2 receptor. EPO activation of HER2 leads to activation of FAK, ERK and β1 integrin. EPO induces a sustained upregulation of MUC4 and HER2. Possible mechanism for the proliferative effects of eosinophils is uncovered.
Collapse
|
86
|
O'Dwyer SM, MacHale E, Sulaiman I, Holmes M, Hughes C, D'Arcy S, Rapcan V, Taylor T, Boland F, Bosnic-Anticevich S, Reilly RB, Ryder SA, Costello RW. The effect of providing feedback on inhaler technique and adherence from an electronic audio recording device, INCA®, in a community pharmacy setting: study protocol for a randomised controlled trial. Trials 2016; 17:226. [PMID: 27142873 PMCID: PMC4855368 DOI: 10.1186/s13063-016-1362-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Accepted: 04/16/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Poor adherence to inhaled medication may lead to inadequate symptom control in patients with respiratory disease. In practice it can be difficult to identify poor adherence. We designed an acoustic recording device, the INCA® (INhaler Compliance Assessment) device, which, when attached to an inhaler, identifies and records the time and technique of inhaler use, thereby providing objective longitudinal data on an individual's adherence to inhaled medication. This study will test the hypothesis that providing objective, personalised, visual feedback on adherence to patients in combination with a tailored educational intervention in a community pharmacy setting, improves adherence more effectively than education alone. METHODS/DESIGN The study is a prospective, cluster randomised, parallel-group, multi-site study conducted over 6 months. The study is designed to compare current best practice in care (i.e. routine inhaler technique training) with the use of the INCA® device for respiratory patients in a community pharmacy setting. Pharmacies are the unit of randomisation and on enrolment to the study they will be allocated by the lead researcher to one of the three study groups (intervention, comparator or control groups) using a computer-generated list of random numbers. Given the nature of the intervention neither pharmacists nor participants can be blinded. The intervention group will receive feedback from the acoustic recording device on inhaler technique and adherence three times over a 6-month period along with inhaler technique training at each of these times. The comparator group will also receive training in inhaler use three times over the 6-month study period but no feedback on their habitual performance. The control group will receive usual care (i.e. the safe supply of medicines and advice on their use). The primary outcome is the rate of participant adherence to their inhaled medication, defined as the proportion of correctly taken doses of medication at the correct time relative to the prescribed interval. Secondary outcomes include exacerbation rates and quality of life measures. Differences in the timing and technique of inhaler use as altered by the interventions will also be assessed. Data will be analysed on an intention-to-treat and a per-protocol basis. Sample size has been calculated with reference to comparisons to be made between the intervention and comparator clusters and indicates 75 participants per cluster. With an estimated 10 % loss to follow-up we will be able to show a 20 % difference between the population means of the intervention and comparator groups with a power of 0.8. The Type I error probability associated with the test of the null hypothesis is 0.05. DISCUSSION This clinical trial will establish whether providing personalised feedback to individuals on their inhaler use improves adherence. It may also be possible to enhance the role of pharmacists in clinical care by identifying patients in whom alteration of either therapy or inhaler device is appropriate. REGISTRATION ClinicalTrials.gov NCT02203266 .
Collapse
|
87
|
Killane I, Sulaiman I, MacHale E, Breathnach A, Taylor TE, Holmes MS, Reilly RB, Costello RW. Predicting asthma exacerbations employing remotely monitored adherence. Healthc Technol Lett 2016; 3:51-5. [PMID: 27222733 DOI: 10.1049/htl.2015.0058] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 03/10/2016] [Accepted: 03/11/2016] [Indexed: 11/20/2022] Open
Abstract
This Letter investigated the efficacy of a decision-support system, designed for respiratory medicine, at predicting asthma exacerbations in a multi-site longitudinal randomised control trial. Adherence to inhaler medication was acquired over 3 months from patients with asthma employing a dose counter and a remote monitoring adherence device which recorded participant's inhaler use: n = 184 (23,656 audio files), 61% women, age (mean ± sd) 49.3 ± 16.4. Data on occurrence of exacerbations was collected at three clinical visits, 1 month apart. The relative risk of an asthma exacerbation for those with good and poor adherence was examined employing a univariate and multivariate modified Poisson regression approach; adjusting for age, gender and body mass index. For all months dose counter adherence was significantly (p < 0.01) higher than remote monitoring adherence. Overall, those with poor adherence had a 1.38 ± 0.34 and 1.42 ± 0.39 (remotely monitored) and 1.25 ± 0.32 and 1.18 ± 0.31 (dose counter) higher relative risk of an exacerbation in model 1 and model 2, respectively. However, this was not found to be statistically significantly different. Remotely monitored adherence holds important clinical information and future research should focus on refining adherence and exacerbation measures. Decision-support systems based on remote monitoring may enhance patient-physician communication, possibly reducing preventable adverse events.
Collapse
|
88
|
Costello RW, Cushen B. A risk stratification tool for exacerbations of COPD: time to switch to DECAF. Thorax 2016; 71:489-90. [PMID: 26883673 DOI: 10.1136/thoraxjnl-2015-208053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
89
|
Taylor TE, Holmes MS, Sulaiman I, Costello RW, Reilly RB. Monitoring Inhaler Inhalations Using an Acoustic Sensor Proximal to Inhaler Devices. J Aerosol Med Pulm Drug Deliv 2016; 29:439-446. [PMID: 26859629 DOI: 10.1089/jamp.2015.1276] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The efficacy of drug delivery from inhalers is very much dependent on the user's peak inspiratory flow rate (PIFR). Current methods to measure PIFR in inhalers are based on subjective checklists. There is a lack of methods currently available to objectively remotely monitor PIFR in pressurized metered dose inhalers (pMDIs) and dry powder inhalers (DPIs). In this study, for the first time, non-contact acoustic methods were employed to estimate PIFR through three commonly used inhalers (Diskus™ DPI, Turbuhaler™ DPI, and Evohaler™ pMDI) with the aim of applying these methods to remotely monitor inhaler inhalation technique in future clinical applications. METHODS Each inhaler was placed inside an airtight container connected to a spirometer to measure PIFR. A high quality microphone was placed 5 cm from the mouthpiece of the inhalers to record inhalation sounds. Over 2000 inhaler inhalation sounds were recorded from 11 healthy participants. A range of temporal and spectral acoustic features from the inhalation sounds were correlated with PIFR. The variation of acoustic features and the repeatability of the inhalation acoustic spectral profile were investigated to further characterize inhaler inhalation sounds and to determine the reliability of acoustics to estimate PIFR. RESULTS All acoustic features were significantly correlated with PIFR (p < 0.001). The mean power of the inhalation sound generated the most consistent correlation across all inhalers [R2 = 0.77 (Diskus™), R2 = 0.7 (Turbuhaler™), R2 = 0.75 (Evohaler™)]. Acoustic features generated low variation and the spectral profile of inhalation sounds was repeatable regardless of flow rate, suggesting that acoustic methods are a reliable method of estimating PIFR. CONCLUSIONS The methods presented in this study may be employed in a wearable monitoring device in future applications to measure inhaler PIFR. Objective monitoring of PIFR in inhalers may help patients improve their inhaler inhalation technique and therefore may be of significant clinical benefit to both patients and clinicians.
Collapse
|
90
|
Sulaiman I, Mac Hale E, Holmes M, Hughes C, D'Arcy S, Taylor T, Rapcan V, Doyle F, Breathnach A, Seheult J, Murphy D, Hunt E, Lane SJ, Sahadevan A, Crispino G, Diette G, Killane I, Reilly RB, Costello RW. A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma. BMJ Open 2016; 6:e009350. [PMID: 26729384 PMCID: PMC4716261 DOI: 10.1136/bmjopen-2015-009350] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION In clinical practice, it is difficult to distinguish between patients with refractory asthma from those with poorly controlled asthma, where symptoms persist due to poor adherence, inadequate inhaler technique or comorbid diseases. We designed an audio recording device which, when attached to an inhaler, objectively identifies the time and technique of inhaler use, thereby assessing both aspects of adherence. This study will test the hypothesis that feedback on these two aspects of adherence when passed on to patients improves adherence and helps clinicians distinguish refractory from difficult-to-control asthma. METHODS This is a single, blind, prospective, randomised, clinical trial performed at 5 research centres. Patients with partially controlled or uncontrolled severe asthma who have also had at least one severe asthma exacerbation in the prior year are eligible to participate. The effect of two types of nurse-delivered education interventions to promote adherence and inhaler technique will be assessed. The active group will receive feedback on their inhaler technique and adherence from the new device over a 3-month period. The control group will also receive training in inhaler technique and strategies to promote adherence, but no feedback from the device. The primary outcome is the difference in actual adherence, a measure that incorporates time and technique of inhaler use between groups at the end of the third month. Secondary outcomes include the number of patients who remain refractory despite good adherence, and differences in the components of adherence after the intervention. Data will be analysed on an intention-to-treat and a per-protocol basis. The sample size is 220 subjects (110 in each group), and loss to follow-up is estimated at 10% which will allow results to show a 10% difference (0.8 power) in adherence between group means with a type I error probability of 0.05. TRIAL REGISTRATION NUMBER NCT01529697; Pre-results.
Collapse
|
91
|
Taylor TE, Holmes MS, Sulaiman I, D'Arcy S, Costello RW, Reilly RB. An acoustic method to automatically detect pressurized metered dose inhaler actuations. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:4611-4. [PMID: 25571019 DOI: 10.1109/embc.2014.6944651] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Chronic respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD) affect over 400 million people and are incurable. The pressurized metered dose inhaler (pMDI) has been the most popular inhaler device in inhaled therapy in recent times. However the pMDIs require good coordination between inhaling and actuating the inhaler to deliver the aerosolized drug most effectively. Poor coordination can greatly reduce the amount of drug delivered to a patient and therefore reducing the control of respiratory disease symptoms. Acoustic methods have been recently employed to monitor inhaler technique quite effectively. This study employs a noninvasive acoustic method to detect actuation sounds in a portable monitoring device. A total of 158 actuation sounds were obtained from a group of healthy subjects (n=5) and subjects suffering from respiratory diseases (n=15). The developed algorithm generated an overall accuracy of 99.7% demonstrating that this method may have clinical potential to monitor pMDI actuation coordination. The informative feedback from this method may also be employed in clinical training to highlight patient actuation technique.
Collapse
|
92
|
Holmes MS, Seheult J, Geraghty C, D'Arcy S, Costello RW, Reilly RB. Using acoustics to estimate inspiratory flow rate and drug removed from a dry powder inhaler. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:6866-9. [PMID: 24111322 DOI: 10.1109/embc.2013.6611135] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Morbidity and mortality rates of chronic respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD) are rising. There is a strong requirement for more effective management of these chronic diseases. Dry powder inhalers (DPIs) are one kind of devices currently employed to deliver medication aimed at controlling asthma and COPD symptoms. Despite their proven effectiveness when used correctly, some patients are unable to reach the inspiratory flow rate required to remove medication from the breath actuated devices and as a result, the medication does not reach the airways. This study employs an acoustic recording device, attached to a common DPI to record the audio signals of simulated inhalations. A rotameter was used to measure the flow rate through the inhaler while a milligram weighing scale was used to measure the amount of drug removed from each simulated inhalation. It was found that a strong correlation existed (R(2)>0.96) when average power, median amplitude, root mean square and mean absolute deviation were used to predict peak inspiratory flow rate. At a flow of 30 L/Min (mean absolute deviation=0.0049), it was found that 77% of the total emitted dose was removed from the inhaler. Results indicate that acoustic measurements may be used in the prediction of inspiratory flow rate and quantity of medication removed from an inhaler.
Collapse
|
93
|
Spina G, Casale P, Albert PS, Alison J, Garcia-Aymerich J, Costello RW, Hernandes NA, van Gestel AJR, Leuppi JD, Mesquita R, Singh SJ, Smeenk FWJM, Tal-Singer R, Wouters EFM, Spruit MA, den Brinker AC. Identifying Physical Activity Profiles in COPD Patients Using Topic Models. IEEE J Biomed Health Inform 2015; 19:1567-76. [DOI: 10.1109/jbhi.2015.2432033] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
94
|
Holmes MS, D'Arcy S, Costello RW, Reilly RB. An acoustic method of automatically evaluating patient inhaler technique. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:1322-5. [PMID: 24109939 DOI: 10.1109/embc.2013.6609752] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Chronic respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD) affect millions of people worldwide. Inhalers are devices utilized to deliver medication in small doses directly to the airways in the treatment of asthma and COPD. Despite the proven effectiveness of inhaler medication in controlling symptoms, many patients suffer from technique errors leading to decreased levels of medication efficacy. This study employs a recording device attached to a commonly used dry powder inhaler (DPI) to obtain the acoustic signals of patients taking their inhaler medication. The audio files provide information on how a patient uses their inhaler over a period of one month. Manually listening to such a large quantity of audio files would be a time consuming and monotonous process and therefore an algorithm that could automatically carry out this task would be of great benefit. An algorithm was thus designed and developed to detect inhalation, exhalation and blister events in the audio signals, analyze the quantity of each event, the order in which the events took place and finally provide a score on the overall performance. The algorithm was tested on a dataset of 185 audio files obtained from five community dwelling asthmatic patients in real world environments. Evaluation of the algorithm on this dataset revealed that it had an accuracy of 92.8% in deciding the correct technique score compared to manual detection methods.
Collapse
|
95
|
Heaney LG, Djukanovic R, Woodcock A, Walker S, Matthews JG, Pavord ID, Bradding P, Niven R, Brightling CE, Chaudhuri R, Arron JR, Choy DF, Cowan D, Mansur A, Menzies-Gow A, Adcock I, Chung KF, Corrigan C, Coyle P, Harrison T, Johnston S, Howarth P, Lordan J, Sabroe I, Bigler J, Smith D, Catley M, May R, Pierre L, Stevenson C, Crater G, Keane F, Costello RW, Hudson V, Supple D, Hardman T. Research in progress: Medical Research Council United Kingdom Refractory Asthma Stratification Programme (RASP-UK). Thorax 2015. [PMID: 26205878 PMCID: PMC4752622 DOI: 10.1136/thoraxjnl-2015-207326] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The UK Refractory Asthma Stratification Programme (RASP-UK) will explore novel biomarker stratification strategies in severe asthma to improve clinical management and accelerate development of new therapies. Prior asthma mechanistic studies have not stratified on inflammatory phenotype and the understanding of pathophysiological mechanisms in asthma without Type 2 cytokine inflammation is limited. RASP-UK will objectively assess adherence to corticosteroids (CS) and examine a novel composite biomarker strategy to optimise CS dose; this will also address what proportion of patients with severe asthma have persistent symptoms without eosinophilic airways inflammation after progressive CS withdrawal. There will be interactive partnership with the pharmaceutical industry to facilitate access to stratified populations for novel therapeutic studies.
Collapse
|
96
|
Mac Hale E, Costello RW, Cowman S. A nurse-led intervention study: Promoting compliance with Diskus Inhaler use in asthma patients. Nurs Open 2014; 1:42-52. [PMID: 27708794 PMCID: PMC5047302 DOI: 10.1002/nop2.10] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2014] [Accepted: 09/01/2014] [Indexed: 11/11/2022] Open
Abstract
AIM To examine the impact of a nurse-led patient assessment and education programme in promoting compliance with inhaler use in asthma patients. DESIGN A quasi-experimental pre-test and post-test design. METHODS A sample of asthmatic patients (N = 21) were recruited from the population of patients attending an asthma clinic. An Inhaler Proficiency Schedule (IPS) was developed and validated. At each visit, participants were requested to demonstrate their inhaler technique. The participants were investigated as to their confidence level with self-administration of their inhaler and adherence to prescribed doses. This information was recorded on a Patient-Reported Behaviour (PRB) questionnaire. RESULTS Technique, compliance and patient confidence levels improved with nurse-led education repeated over three visits; this was sustained on measurement at 6 months following completion of the education programme.
Collapse
|
97
|
Holmes MS, Seheult JN, O'Connell P, D'Arcy S, Ehrhardt C, Healy AM, Costello RW, Reilly RB. An Acoustic-Based Method to Detect and Quantify the Effect of Exhalation into a Dry Powder Inhaler. J Aerosol Med Pulm Drug Deliv 2014; 28:247-53. [PMID: 25393346 DOI: 10.1089/jamp.2014.1169] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Dry powder inhaler (DPI) users frequently exhale into their inhaler mouthpiece before the inhalation step. This error in technique compromises the integrity of the drug and results in poor bronchodilation. This study investigated the effect of four exhalation factors (exhalation flow rate, distance from mouth to inhaler, exhalation duration, and relative air humidity) on dry powder dose delivery. Given that acoustic energy can be related to the factors associated with exhalation sounds, we then aimed to develop a method of identifying and quantifying this critical inhaler technique error using acoustic based methods. METHODS An in vitro test rig was developed to simulate this critical error. The effect of the four factors on subsequent drug delivery were investigated using multivariate regression models. In a further study we then used an acoustic monitoring device to unobtrusively record the sounds 22 asthmatic patients made whilst using a Diskus(™) DPI. Acoustic energy was employed to automatically detect and analyze exhalation events in the audio files. RESULTS All exhalation factors had a statistically significant effect on drug delivery (p<0.05); distance from the inhaler mouthpiece had the largest effect size. Humid air exhalations were found to reduce the fine particle fraction (FPF) compared to dry air. In a dataset of 110 audio files from 22 asthmatic patients, the acoustic method detected exhalations with an accuracy of 89.1%. We were able to classify exhalations occurring 5 cm or less in the direction of the inhaler mouthpiece or recording device with a sensitivity of 72.2% and specificity of 85.7%. CONCLUSIONS Exhaling into a DPI has a significant detrimental effect. Acoustic based methods can be employed to objectively detect and analyze exhalations during inhaler use, thus providing a method of remotely monitoring inhaler technique and providing personalized inhaler technique feedback.
Collapse
|
98
|
Higgins G, Buchanan P, Perriere M, Al-Alawi M, Costello RW, Verriere V, McNally P, Harvey BJ, Urbach V. Activation of P2RY11 and ATP release by lipoxin A4 restores the airway surface liquid layer and epithelial repair in cystic fibrosis. Am J Respir Cell Mol Biol 2014; 51:178-90. [PMID: 24588705 DOI: 10.1165/rcmb.2012-0424oc] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
In cystic fibrosis (CF), the airway surface liquid (ASL) height is reduced as a result of impaired ion transport, which favors bacterial colonization and inflammation of the airway and leads to progressive lung destruction. Lipoxin (LX)A4, which promotes resolution of inflammation, is inadequately produced in the airways of patients with CF. We previously demonstrated that LXA4 stimulates an ASL height increase and epithelial repair. Here we report the molecular mechanisms involved in these processes. We found that LXA4 (1 nM) induced an apical ATP release from non-CF (NuLi-1) and CF (CuFi-1) airway epithelial cell lines and CF primary cultures. The ATP release induced by LXA4 was completely inhibited by antagonists of the ALX/FPR2 receptor and Pannexin-1 channels. LXA4 induced an increase in intracellular cAMP and calcium, which were abolished by the selective inhibition of the P2RY11 purinoreceptor. Pannexin-1 and ATP hydrolysis inhibition and P2RY11 purinoreceptor knockdown all abolished the increase of ASL height induced by LXA4. Inhibition of the A2b adenosine receptor did not affect the ASL height increase induced by LXA4, whereas the PKA inhibitor partially inhibited this response. The stimulation of NuLi-1 and CuFi-1 cell proliferation, migration, and wound repair by LXA4 was inhibited by the antagonists of Pannexin-1 channel and P2RY11 purinoreceptor. Taken together, our results provide evidence for a novel role of LXA4 in stimulating apical ATP secretion via Pannexin-1 channels and P2RY11 purinoreceptors activation leading to an ASL height increase and epithelial repair.
Collapse
|
99
|
Seheult JN, Costello S, Tee KC, Bholah T, Al Bannai H, Sulaiman I, Costello RW. Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study. SPRINGERPLUS 2014; 3:496. [PMID: 25279290 PMCID: PMC4164676 DOI: 10.1186/2193-1801-3-496] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Accepted: 08/18/2014] [Indexed: 11/18/2022]
Abstract
Drug delivery from a Dry Powder Inhaler (DPI) is dependent on the peak inspiratory flow rate (PIFR) generated. Currently available methods for estimating PIFR from most DPIs are limited and mainly rely on subjective assessment. We aim to show that spirometric and Diskus™ PIFR and Inspiratory Vital Capacity (IVC) are related to the underlying respiratory condition and that spirometric PIFR can be used to assess whether Diskus™ PIFR will be adequate when using this DPI. Healthy volunteers and patients with asthma, COPD, neuromuscular disease and non-respiratory disorders were recruited (n = 85). Demographics and baseline lung function by spirometry were recorded. Flow and volume readings were taken while patients used a Diskus™ DPI, housed in an airtight container connected to a spirometer. T-tests were performed to compare mean spirometric and Diskus™ PIFR/ IVC between groups. Stepwise regression analysis of Diskus™ PIFR versus spirometric PIFR, spirometric IVC, age, gender, condition, BMI, FEV1 and FVC was performed. The Diskus™ PIFR for the COPD and Neuromuscular Disease group was more than 10 L/min lower than the Healthy or Asthma groups (p < 0.05). The mean spirometric and Diskus™ IVC of the Healthy group was significantly (>0.75 L) higher than the mean for the other three groups (p < 0.05). Diskus™ PIFR was moderately correlated with spirometric PIFR and age (Adjusted R2 = 0.58, p < 0.0001). PIFR generated using a Diskus™ DPI is dependent on the underlying disease and age. A spirometric PIFR of less than 196 L/min should prompt further investigation into the suitability of a patient for a Diskus™ DPI, with possible consideration of alternate devices.
Collapse
|
100
|
Al-Alawi M, Buchanan P, Verriere V, Higgins G, McCabe O, Costello RW, McNally P, Urbach V, Harvey BJ. Physiological levels of lipoxin A4 inhibit ENaC and restore airway surface liquid height in cystic fibrosis bronchial epithelium. Physiol Rep 2014; 2:2/8/e12093. [PMID: 25107986 PMCID: PMC4246599 DOI: 10.14814/phy2.12093] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
In cystic fibrosis (CF), the airway surface liquid (ASL) is depleted. We previously demonstrated that lipoxin A4 (LXA4) can modulate ASL height (ASLh) through actions on Cl(-) transport. Here, we report novel effects of lipoxin on the epithelial Na(+) channel ENaC in this response. ASL dynamics and ion transport were studied using live-cell confocal microscopy and short-circuit current measurements in CF (CuFi-1) and non-CF (NuLi-1) cell cultures. Low physiological concentrations of LXA4 in the picomolar range produced an increase in ASLh which was dependent on inhibition of an amiloride-sensitive Na(+) current and stimulation of a bumetanide-sensitive Cl(-) current. These ion transport and ASLh responses to LXA4 were blocked by Boc-2 an inhibitor of the specific LXA4 receptor ALX/FPR2. LXA4 affected the subcellular localization of its receptor and enhanced the localization of ALX/FPR2 at the apical membrane of CF cells. Our results provide evidence for a novel effect of low physiological concentrations of LXA4 to inhibit airway epithelial Na(+) absorption that results in an ASL height increase in CF airway epithelia.
Collapse
|