26
|
Lee RC, Ekaette E, Kelly KL, Craighead P, Newcomb C, Dunscombe P. Implications of Cancer Staging Uncertainties in Radiation Therapy Decisions. Med Decis Making 2016; 26:226-38. [PMID: 16751321 DOI: 10.1177/0272989x06288684] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Introduction . Radiation therapy (RT) for cancer is a critical medical procedure that occurs in a complex environment involving numerous health professionals, hardware, software, and equipment. Uncertainties and potential incidents can lead to inappropriate administration of radiation to patients, with sometimes catastrophic consequences such as premature death or appreciably impaired quality of life. The authors evaluate the impact of incorrectly staging (i.e., estimation of extent of cancer) breast cancer patients and resulting inappropriate treatment decisions. Methods . The authors employ analytic and simulation methods in an influence-diagram framework to estimate the probability of incorrect staging and treatment decisions. As inputs, they use a combination of literature information on the accuracy and precision of pathology and tests as well as expert judgment. Sensitivity and value-of-information analyses are conducted to identify important uncertainties. Results and conclusions . The authors find a small but nontrivial probability that breast cancer patients will be incorrectly staged and thus may be subjected to inappropriate treatment. Results are sensitive to a number of variables, and some routinely used tests for metastasis have very limited information value. This work has implications for the methods used in cancer staging, and the methods are generalizable for quantitative risk assessment of treatment errors.
Collapse
|
27
|
Chiou SY, Lee RC, Chi KH, Chia-Hsien Cheng J, Chiang JH, Chang CY. The triple-phase CT image appearance of post-irradiated livers. Acta Radiol 2016; 42:526-31. [PMID: 11552892 DOI: 10.1080/028418501127347115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Objective To evaluate the sequential CT appearance of the liver after hepatic irradiation and to investigate the correlation between CT findings and radiation-induced hepatic injury. Material and Methods: The triple-phase CT images of 18 patients with hepatocellular carcinomas (HCC) after hepatic irradiation were retrospectively reviewed (in total 41 CT studies). The high-dose region within the liver was defined as the area receiving more than 90% of the prescribed irradiation dose. The mean radiation dose was 55.5 Gy. Density changes and patterns of enhancement in the high-dose region were classified as three types: type I, constant low-density change in all phases; type II, low-density change in both pre-contrast and arterial phases, and iso-density change in the portal phase; type III, low- or iso-density change in the pre-contrast phase, low- or high-density change in the arterial phase, and persistent high-density change in the portal phase. The interval between completion of radiotherapy and the CT examinations ranged from 9 to 469 days, with a mean of 147 days. Results: Nine of the 41 CT studies presented with type I, 9 with type II, and 16 with type III CT findings. The mean interval between completion of radiotherapy and the appearance of types I, II, and III CT findings were 74, 183, and 220 days, respectively. The interval was significantly shorter for type I findings than for type II and type III. The difference in interval was not significant between type II and type III. A type I finding with constant low-density change in the high-dose region of the liver was the most common pattern of CT findings within the first 3 months after hepatic irradiation. Either types II or III findings were frequently seen after 3 months. Conclusion: The sequential CT appearance and the density changes may indicate correlation with the pathogenesis of veno-occlusive disease.
Collapse
|
28
|
Simon JC, Lucas SA, Staninec M, Tom H, Chan KH, Darling CL, Cozin MJ, Lee RC, Fried D. Near-IR transillumination and reflectance imaging at 1,300 nm and 1,500-1,700 nm for in vivo caries detection. Lasers Surg Med 2016; 48:828-836. [PMID: 27389018 DOI: 10.1002/lsm.22549] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2016] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Several studies suggest that near-IR imaging methods at wavelengths longer than 1,300 nm have great potential for caries detection. In this study, the diagnostic performance of both near-IR transillumination and near-IR reflectance was assessed on teeth scheduled for extraction due to orthodontic treatment (n = 109 teeth on 40 test subjects). METHODS Three intra-oral near-IR imaging probes were fabricated for the acquisition of in vivo images using a high definition InGaAs camera and near-IR broadband light sources. Two transillumination probes provided occlusal and approximal images using 1,300 nm light which manifests the highest transparency in enamel. A third reflectance probe utilized cross-polarization and operated at wavelengths greater than 1,500 nm where water absorption is higher which reduces the reflectivity of sound tissues, significantly increasing lesion contrast. Teeth were collected after extraction and sectioned and examined with polarized light microscopy and microradiography which served as the gold standard. In addition, radiographs were taken of the teeth and the diagnostic performance of near-IR imaging was compared with radiography. RESULTS Near-IR imaging was significantly more sensitive (P < 0.05) than radiography for the detection of lesions on both occlusal and proximal surfaces. CONCLUSION Near-IR imaging methods are ideally suited for screening all tooth surfaces for carious lesions. Lasers Surg. Med. 48:828-836, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
|
29
|
|
30
|
Lee RC, Staninec M, Le O, Fried D. Infrared Methods for Assessment of the Activity of Natural Enamel Caries Lesions. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2016; 22:6803609. [PMID: 27642246 PMCID: PMC5021449 DOI: 10.1109/jstqe.2016.2542481] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
New diagnostic methods are needed for the accurate assessment of caries lesion activity to establish the need for surgical treatment. Detection of the highly mineralized surface layer that forms near the surface of the lesions as a result of remineralization is important for diagnosis of the lesion activity. Previous studies have demonstrated that novel imaging methods can be used to detect remineralization of artificial enamel caries lesions. In this paper, the activity of natural enamel caries lesions was assessed in-vitro via detection of the surface layer with PS-OCT and dehydration rate measurements with NIR reflectance and thermal imaging modalities. An automated approach for detecting the surface layer with PS-OCT yielded high sensitivity (= 0.79) and high specificity (= 0.93) with moderate correlation (R2 = 0.5920) with histology. Significant differences in dehydration rate measurements were found between the active and the arrested lesions using both the NIR reflectance and thermal imaging modalities. These results demonstrate that these novel imaging methods are ideally suited for nondestructive, noninvasive and quantitative measurement of lesion activity during a single clinical examination in real-time.
Collapse
|
31
|
Chan KH, Tom H, Lee RC, Kang H, Simon JC, Staninec M, Darling CL, Pelzner RB, Fried D. Clinical monitoring of smooth surface enamel lesions using CP-OCT during nonsurgical intervention. Lasers Surg Med 2016; 48:915-923. [PMID: 26955902 DOI: 10.1002/lsm.22500] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/22/2016] [Indexed: 11/10/2022]
Abstract
INTRODUCTION Studies have shown that cross-polarization optical coherence tomography (CP-OCT) can be used to image the internal structure of carious lesions in vivo. The objective of this study was to show that CP-OCT can be used to monitor changes in the internal structure of early active carious lesions on smooth surfaces during non-surgical intervention with fluoride. METHODS Lesions on the smooth surfaces of teeth were imaged using CP-OCT on 17 test subjects. Lesion structural changes were monitored during fluoride varnish application at 6-week intervals for 30 weeks. The lesion depth (Ld ), integrated reflectivity (ΔR), and surface zone thickness (Sz ) were monitored. RESULTS A distinct transparent surface zone that may be indicative of lesion arrestment was visible in CP-OCT images on 62/63 lesions before application of fluoride varnish. The lesion depth and internal structure were resolved for all the lesions. The overall change in the mean values for Ld , ΔR, and Sz for all the lesions was minimal and was not significant during the study (P > 0.05). Only 5/63 lesions manifested a significant increase in Sz during intervention. CONCLUSION Even though it appears that most of the lesions manifested little change with fluoride varnish application in the 30 weeks of the study, CP-OCT was able to measure the depth and internal structure of all the lesions including the thickness of the important transparent surface zone located at the surface of the lesions, indicating that CP-OCT is ideally suited for monitoring lesion severity in vivo. Lasers Surg. Med. 48:915-923, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
|
32
|
Lee RC, Darling CL, Fried D. Assessment of remineralized dentin lesions with thermal and near-infrared reflectance imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2016; 9692:96920B. [PMID: 27006522 PMCID: PMC4799994 DOI: 10.1117/12.2218661] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Accurate detection and measurement of the highly mineralized surface layer that forms on caries lesions is important for the diagnosis of lesion activity. Previous studies have demonstrated that optical imaging methods can be used to measure the degree of remineralization on enamel lesions. The purpose of this study was to determine if thermal and near-IR reflectance imaging could be used to assess the remineralization process in simulated dentin lesions. Artificial bovine (n=15) dentin lesions were prepared by immersion in a demineralization solution for 24 hours and they were subsequently placed in an acidic remineralization solution for up to 12 days. The samples were dehydrated using an air spray for 30 seconds and imaged using thermal and InGaAs cameras. The area enclosed by the time-temperature curve, ΔQ, from thermal imaging decreased significantly with longer periods of remineralization. However, near-IR reflectance intensity differences, ΔI, before and after dehydration failed to show any significant relationship with the degree of remineralization. This study shows that thermal imaging can be used for the assessment of the remineralization of dentin lesions.
Collapse
|
33
|
Tam W, Lee RC, Lin B, Simon JC, Fried D. Assessment of simulated lesions on primary teeth with near-infrared imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2016; 9692:96920V. [PMID: 26997743 PMCID: PMC4793935 DOI: 10.1117/12.2218660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Previous studies have demonstrated that the structural changes on enamel due to demineralization and remineralization can be exploited through optical imaging methods such as QLF, thermal and NIR imaging. The purpose of this study is to investigate whether PS-OCT and NIR reflectance imaging can be utilized to assess lesion structure in artificial enamel lesions on the smooth surfaces of primary teeth exposed to fluoride. The smooth coronal surfaces of primary teeth (n=25) were divided into 4 windows: sound, demineralization, demineralization with remineralization and APF with demineralization. Windows were treated with either acidulated phosphate fluoride (APF) for 1 minute, a demineralization solution for 4 days, and/or an acidic remineralization solution for 12 days. The samples were imaged using PS-OCT, QLF and NIR reflectance at 1400-1700 nm wavelengths. This study demonstrated that both PS-OCT and NIR reflectance imaging were suitable for assessing lesion structure in the smooth surfaces of primary dentition.
Collapse
|
34
|
Simon JC, A Lucas S, Lee RC, Darling CL, Staninec M, Vaderhobli R, Pelzner R, Fried D. Near-infrared imaging of secondary caries lesions around composite restorations at wavelengths from 1300-1700-nm. Dent Mater 2016; 32:587-95. [PMID: 26876234 DOI: 10.1016/j.dental.2016.01.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 08/24/2015] [Accepted: 01/18/2016] [Indexed: 10/22/2022]
Abstract
BACKGROUND AND OBJECTIVES Current clinical methods for diagnosing secondary caries are unreliable for identifying the early stages of decay around restorative materials. The objective of this study was to access the integrity of restoration margins in natural teeth using near-infrared (NIR) reflectance and transillumination images at wavelengths between 1300 and 1700-nm and to determine the optimal NIR wavelengths for discriminating composite materials from dental hard tissues. MATERIALS AND METHODS Twelve composite margins (n=12) consisting of class I, II and V restorations were chosen from ten extracted teeth. The samples were imaged in vitro using NIR transillumination and reflectance, polarization sensitive optical coherence tomography (PS-OCT) and a high-magnification digital microscope. Samples were serially sectioned into 200-μm slices for histological analysis using polarized light microscopy (PLM) and transverse microradiography (TMR). Two independent examiners evaluated the presence of demineralization at the sample margin using visible detection with 10× magnification and NIR images presented digitally. Composite restorations were placed in sixteen sound teeth (n=16) and imaged at multiple NIR wavelengths ranging from λ=1300 to 1700-nm using NIR transillumination. The image contrast was calculated between the composite and sound tooth structure. RESULTS Intensity changes in NIR images at wavelengths ranging from 1300 to 1700-nm correlate with increased mineral loss measured using TMR. NIR reflectance and transillumination at wavelengths coincident with increased water absorption yielded significantly higher (P<0.001) contrast between sound enamel and adjacent demineralized enamel. In addition, NIR reflectance exhibited significantly higher (P<0.01) contrast between sound enamel and adjacent composite restorations than visible reflectance. SIGNIFICANCE This study shows that NIR imaging is well suited for the rapid screening of secondary caries lesions.
Collapse
|
35
|
Adams ZW, Moreland A, Cohen JR, Lee RC, Hanson RF, Danielson CK, Self-Brown S, Briggs EC. Polyvictimization: Latent profiles and mental health outcomes in a clinical sample of adolescents. PSYCHOLOGY OF VIOLENCE 2016; 6:145-155. [PMID: 26958417 PMCID: PMC4779364 DOI: 10.1037/a0039713] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
OBJECTIVE Exposure to multiple traumatic events (polyvictimization) is a reliable predictor of deleterious health outcomes and risk behaviors in adolescence. The current study extends the literature on the prevalence and consequences of adolescent trauma exposure by (a) empirically identifying and characterizing trauma exposure profiles in a large, ethnically diverse, multi-site, clinical sample of adolescents, and (b) evaluating relations among identified profiles with demographic characteristics and clinical correlates. METHOD Data from the National Child Traumatic Stress Network Core Data Set were used to identify and characterize victimization profiles using latent class analysis in a sample of 3,485 adolescents (ages 13-18, 63% female, 35.7% White, 23.2% Black/African American, 35.0% Hispanic/Latino). Multiple measures of psychological distress and risk behaviors were evaluated as covariates of trauma exposure classes. RESULTS Five trauma exposure classes, or profiles, were identified. Four classes-representing approximately half the sample-were characterized by polyvictimization. Polyvictimization classes were differentiated on number of trauma types, whether emotional abuse occurred, and whether emotional abuse occurred over single or multiple developmental epochs. Unique relations with demographic characteristics and mental health outcomes were observed. DISCUSSION Results suggest polyvictimization is not a unidimensional phenomenon but a diverse set of trauma exposure experiences with unique correlates among youth. Further research on prevention of polyvictimization and mechanisms linking chronic trauma exposure, gender, and ethnicity to negative outcomes is warranted.
Collapse
|
36
|
Lee RC, Darling CL, Fried D. Assessment of remineralization via measurement of dehydration rates with thermal and near-IR reflectance imaging. J Dent 2015; 43:1032-42. [PMID: 25862275 DOI: 10.1016/j.jdent.2015.03.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Accepted: 03/19/2015] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES Previous studies have demonstrated that the optical changes due to the loss of water from porous lesions can be exploited to assess lesion severity with QLF, thermal and near-IR imaging. Since arrested lesions are less permeable to water due to the highly mineralized surface layer, changes in the rate of water loss can be related to changes in lesion structure. The purpose of this study was to investigate whether the rate of water loss correlates with the degree of remineralization and whether that rate can be measured using thermal and near-IR reflectance imaging. METHODS Artificial bovine enamel lesions (n=30) were prepared by immersion in a demineralization solution for either 8 and 24 h and they were subsequently placed in an acidic remineralization solution for different periods. The samples were dehydrated using an air spray for 30s and surfaces were imaged using a thermal camera and an InGaAs camera at 1300-1700 nm wavelengths. RESULTS The area enclosed by the time-temperature curve, ΔQ, from thermal imaging showed significant differences (P<0.05) between the lesion window and other windows. Near-IR reflectance intensity differences, ΔI, before and after dehydration decreased with longer periods of remineralization. Only near-IR reflectance imaging was capable of detecting significant differences (P<0.05) between the different periods of remineralization. CONCLUSIONS This study demonstrated that both thermal and near-IR reflectance imaging were suitable for the detection of remineralization in simulated caries lesions and near-IR wavelengths longer than 1400 nm are well suited for the assessment of remineralization.
Collapse
|
37
|
Lee RC, Darling CL, Fried D. Assessment of remineralization in simulated enamel lesions via dehydration with near-IR reflectance imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2015; 9306. [PMID: 25914494 DOI: 10.1117/12.2083655] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Previous studies have demonstrated that near-IR imaging can be used to nondestructively monitor the severity of enamel lesions. Arrested lesions typically have a highly mineralized surface layer that reduces permeability and limits diffusion into the lesion. The purpose of this study was to investigate whether the rate of water loss correlates with the degree of remineralization using near-IR reflectance imaging. Artificial bovine (n=15) enamel lesions were prepared by immersion in a demineralization solution for 24 hours and they were subsequently placed in an acidic remineralization solution for different periods. The samples were dehydrated using an air spray for 30 seconds and surfaces were imaged using an InGaAs camera at 1300-1700 nm wavelengths. Near-IR reflectance intensity differences before and after dehydration decreased with longer periods of remineralization. This study demonstrated that near-IR reflectance imaging was suitable for the detection of remineralization in simulated caries lesions and near-IR wavelengths longer than 1400 nm are well suited for the assessment of remineralization.
Collapse
|
38
|
Lee RC, Kang H, Darling CL, Fried D. Automated assessment of the remineralization of artificial enamel lesions with polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:2950-62. [PMID: 25401009 PMCID: PMC4230881 DOI: 10.1364/boe.5.002950] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/25/2014] [Accepted: 07/28/2014] [Indexed: 05/03/2023]
Abstract
Accurate measurement of the highly mineralized transparent surface layer that forms on caries lesions is important for diagnosis of the lesion activity because chemical intervention can slow or reverse the caries process via remineralization. Previous in-vitro and in-vivo studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can nondestructively image the subsurface lesion structure and the highly mineralized transparent surface zone of caries lesions. The purpose of this study was to develop an approach to automatically process 3-dimensional PS-OCT images and to accurately assess the remineralization process in simulated enamel lesions. Artificial enamel lesions were prepared on twenty bovine enamel blocks using two models to produce varying degree of demineralization and remineralization. The thickness of the transparent surface layer and the integrated reflectivity of the subsurface lesion were measured using PS-OCT. The automated transparent surface layer detection algorithm was able to successfully detect the transparent surface layers with high sensitivity ( = 0.92) and high specificity ( = 0.97). The estimated thickness of the transparent surface layer showed a strong correlation with polarized light microscopy (PLM) measurements of all regions (R(2) = 0.90). The integrated reflectivity, ΔR, and the integrated mineral loss, ΔZ, showed a moderate correlation (R(2) = 0.32). This study demonstrates that PS-OCT can automatically measure the changes in artificial enamel lesion structure and severity upon exposure to remineralization solutions.
Collapse
|
39
|
Kiser LJ, Stover CS, Navalta CP, Dorado J, Vogel JM, Abdul-Adil JK, Kim S, Lee RC, Vivrette R, Briggs EC. Effects of the child-perpetrator relationship on mental health outcomes of child abuse: it's (not) all relative. CHILD ABUSE & NEGLECT 2014; 38:1083-1093. [PMID: 24661693 DOI: 10.1016/j.chiabu.2014.02.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2013] [Revised: 02/25/2014] [Accepted: 02/28/2014] [Indexed: 06/03/2023]
Abstract
The present study was conducted to better understand the influence of the child-perpetrator relationship on responses to child sexual and physical trauma for a relatively large, ethnically diverse sample of children and youth presenting for clinical evaluation and treatment at child mental health centers across the United States. This referred sample includes 2,133 youth with sexual or physical trauma as their primary treatment focus. Analyses were conducted to ascertain whether outcomes were dependent on the perpetrator's status as a caregiver vs. non-caregiver. Outcome measures included psychiatric symptom and behavior problem rating scales. For sexual trauma, victimization by a non-caregiver was associated with higher posttraumatic stress, internalizing and externalizing behavior problems, depression, and dissociation compared to youth victimized by a caregiver. For physical trauma, victimization by a non-caregiver was also associated with higher posttraumatic symptoms and internalizing behavior problems. The total number of trauma types experienced and age of physical or sexual trauma onset also predicted several outcomes for both groups, although in disparate ways. These findings are consistent with other recent studies demonstrating that perpetration of abuse by caregivers results in fewer symptoms and problems than abuse perpetrated by a non-caregiving relative. Thus, clinicians should not make a priori assumptions that children and adolescents who are traumatized by a parent/caregiver would have more severe symptoms than youth who are traumatized by a non-caregiver. Further exploration of the role of the perpetrator and other trauma characteristics associated with the perpetrator role is needed to advance our understanding of these findings and their implications for clinical practice.
Collapse
|
40
|
Lee RC, Darling CL, Fried D. Automated detection of remineralization in simulated enamel lesions with PS-OCT. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2014; 8929:89290E. [PMID: 25075267 DOI: 10.1117/12.2045676] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Previous in vitro and in vivo studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can be used to nondestructively image the subsurface structure and measure the thickness of the highly mineralized transparent surface zone of caries lesions. There are structural differences between active lesions and arrested lesions, and the surface layer thickness may correlate with activity of the lesion. The purpose of this study was to develop a method that can be used to automatically detect and measure the thickness of the transparent surface layer in PS-OCT images. Automated methods of analysis were used to measure the thickness of the transparent layer and the depth of the bovine enamel lesions produced using simulated caries models that emulate demineralization in the mouth. The transparent layer thickness measured with PS-OCT correlated well with polarization light microscopy (PLM) measurements of all regions (r2=0.9213). This study demonstrates that PS-OCT can automatically detect and measure thickness of the transparent layer formed due to remineralization in simulated caries lesions.
Collapse
|
41
|
Greeson JKP, Briggs EC, Layne CM, Belcher HME, Ostrowski SA, Kim S, Lee RC, Vivrette RL, Pynoos RS, Fairbank JA. Traumatic childhood experiences in the 21st century: broadening and building on the ACE studies with data from the National Child Traumatic Stress Network. JOURNAL OF INTERPERSONAL VIOLENCE 2014; 29:536-556. [PMID: 24144720 DOI: 10.1177/0886260513505217] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The study objectives were to (a) examine the association between total number of trauma types experienced and child/adolescent behavioral problems and (b) determine whether the number of trauma types experienced predicted youth behavioral problems above and beyond demographic characteristics, using a diverse set of 20 types of trauma. Data came from the National Child Traumatic Stress Network's (NCTSN) Core Data Set (CDS), which includes youth assessed and treated for trauma across the United States. Participants who experienced at least one type of trauma were included in the sample (N = 11,028; age = 1½-18 years; 52.3% girls). Random effects models were used to account for possible intraclass correlations given treatment services were provided at different NCTSN centers. Logistic regression analyses were used to investigate associations among demographic characteristics, trauma, and emotional and behavioral problems as measured by the Child Behavior Checklist (CBCL). Significant dose-response relations were found between total number of trauma types and behavior problems for all CBCL scales, except Sleep, one of the subscales only administered to 1½- to 5-year-olds. Thus, each additional trauma type endorsed significantly increased the odds for scoring above the clinical threshold. Results provide further evidence of strong associations between diverse traumatic childhood experiences and a diverse range of behavior problems, and underscore the need for a trauma-informed public health and social welfare approach to prevention, risk reduction, and early intervention for traumatized youth.
Collapse
|
42
|
Staninec M, Douglas SM, Darling CL, Chan K, Kang H, Lee RC, Fried D. Non-destructive clinical assessment of occlusal caries lesions using near-IR imaging methods. Lasers Surg Med 2011; 43:951-9. [PMID: 22109697 PMCID: PMC3241877 DOI: 10.1002/lsm.21139] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/21/2011] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Enamel is highly transparent in the near-IR (NIR) at wavelengths near 1,300 nm, and stains are not visible. The purpose of this study was to use NIR transillumination and optical coherence tomography (OCT) to estimate the severity of caries lesions on occlusal surfaces both in vivo and on extracted teeth. METHODS Extracted molars with suspected occlusal lesions were examined with OCT and polarization sensitive OCT (PS-OCT), and subsequently sectioned and examined with polarized light microscopy (PLM) and transverse microradiography (TMR). Teeth in test subjects with occlusal caries lesions that were not cavitated or visible on radiographs were examined using NIR transillumination at 1,310 nm using a custom built probe attached to an indium gallium arsenide (InGaAs) camera and a linear OCT scanner. After imaging, cavities were prepared using dye staining to guide caries removal and physical impressions of the cavities were taken. RESULTS The lesion severity determined from OCT and PS-OCT scans in vitro correlated with the depth determined using PLM and TMR. Occlusal caries lesions appeared in NIR images with high contrast in vivo. OCT scans showed that most of the lesions penetrated to dentin and spread laterally below the sound enamel. CONCLUSION This study demonstrates that both NIR transillumination and OCT are promising new methods for the clinical diagnosis of occlusal caries.
Collapse
|
43
|
Staninec M, Douglas SM, Darling CL, Chan K, Kang H, Lee RC, Fried D. Non-destructive clinical assessment of occlusal caries lesions using near-IR imaging methods. Lasers Surg Med 2011. [PMID: 22109697 DOI: 10.1002/lsm.v43.10] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
OBJECTIVE Enamel is highly transparent in the near-IR (NIR) at wavelengths near 1,300 nm, and stains are not visible. The purpose of this study was to use NIR transillumination and optical coherence tomography (OCT) to estimate the severity of caries lesions on occlusal surfaces both in vivo and on extracted teeth. METHODS Extracted molars with suspected occlusal lesions were examined with OCT and polarization sensitive OCT (PS-OCT), and subsequently sectioned and examined with polarized light microscopy (PLM) and transverse microradiography (TMR). Teeth in test subjects with occlusal caries lesions that were not cavitated or visible on radiographs were examined using NIR transillumination at 1,310 nm using a custom built probe attached to an indium gallium arsenide (InGaAs) camera and a linear OCT scanner. After imaging, cavities were prepared using dye staining to guide caries removal and physical impressions of the cavities were taken. RESULTS The lesion severity determined from OCT and PS-OCT scans in vitro correlated with the depth determined using PLM and TMR. Occlusal caries lesions appeared in NIR images with high contrast in vivo. OCT scans showed that most of the lesions penetrated to dentin and spread laterally below the sound enamel. CONCLUSION This study demonstrates that both NIR transillumination and OCT are promising new methods for the clinical diagnosis of occlusal caries.
Collapse
|
44
|
Cook LS, Neilson HK, Lee RC. Reply. Am J Obstet Gynecol 2010. [DOI: 10.1016/j.ajog.2010.04.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
45
|
Dunscombe PB, Ekaette EU, Lee RC, Cooke DL. Taxonometric applications in radiotherapy incident analysis. Int J Radiat Oncol Biol Phys 2008; 71:S200-3. [PMID: 18406929 DOI: 10.1016/j.ijrobp.2007.06.085] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2007] [Revised: 06/01/2007] [Accepted: 06/02/2007] [Indexed: 11/19/2022]
Abstract
Recent publications in both the scientific and the popular press have highlighted the risks to which patients expose themselves when entering a healthcare system. Patient safety issues are forcing us to, not only acknowledge that incidents do occur, but also actively develop the means for assessing and managing the risks of such incidents. To do this, we ideally need to know the probability of an incident's occurrence, the consequences or severity for the patient should it occur, and the basic causes of the incident. A structured approach to the description of failure modes is helpful in terms of communication, avoidance of ambiguity, and, ultimately, decision making for resource allocation. In this report, several classification schemes or taxonomies for use in risk assessment and management are discussed. In particular, a recently developed approach that reflects the activity domains through which the patient passes and that can be used as a basis for quantifying incident severity is described. The estimation of incident severity, which is based on the concept of the equivalent uniform dose, is presented in some detail. We conclude with a brief discussion on the use of a defined basic-causes table and how adding such a table to the reports of incidents can facilitate the allocation of resources.
Collapse
|
46
|
Lee RC, Zou D, Demetrick DJ, Difrancesco LM, Fassbender K, Stewart D. Costs associated with diffuse large B-cell lymphoma patient treatment in a Canadian integrated cancer care center. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2008; 11:221-30. [PMID: 18380634 DOI: 10.1111/j.1524-4733.2007.00227.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
OBJECTIVE The objective of this study was to provide a detailed comparative microcosting analysis for two cancer treatment pathways to contribute evidence for resource allocation and operational decision-making in a Canadian cancer care context. METHODS We estimated direct medical costs (in 2004 CAN$) of the entire pathway of care for diffuse large B-cell lymphoma (DLBCL) patients in a large Canadian cancer treatment center. Patient samples were defined as those who received R-CHOP (rituximab plus cyclophosphamide, doxorubicin, vincristine, and prednisone; n = 85) or CHOP (i.e., without rituximab; n = 86) as first-line treatment. All subsequent treatments including palliative care for these patient samples were assessed. Hospitalization costs and unit costs of medical resources were collected from integrated medical organizations. Individual patient resource consumption was assessed via medical chart review. RESULTS For first-line treatment, drug cost was the largest contributor to total cost, followed by hospitalization cost. Rituximab was the largest contributor to mean cost differences between R-CHOP and CHOP treatments. For treatments subsequent to first-line treatment, no significant cost differences were found. Hospitalization and transplantation costs were the two largest constituents of total costs subsequent to first-line treatment, followed by drug cost. Patients with advanced stage disease cost significantly more than patients with limited stage disease. CONCLUSION This is the first detailed microcosting study that has employed consistent local data to estimate total medical costs for DLBCL patients in Canada. This information is useful for resource allocation planning and operational decisions, because it provides more substantive, relevant evidence as compared to aggregated, literature or extrapolated information.
Collapse
|
47
|
Ekaette E, Lee RC, Cooke DL, Iftody S, Craighead P. Probabilistic fault tree analysis of a radiation treatment system. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2007; 27:1395-1410. [PMID: 18093042 DOI: 10.1111/j.1539-6924.2007.00976.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Inappropriate administration of radiation for cancer treatment can result in severe consequences such as premature death or appreciably impaired quality of life. There has been little study of vulnerable treatment process components and their contribution to the risk of radiation treatment (RT). In this article, we describe the application of probabilistic fault tree methods to assess the probability of radiation misadministration to patients at a large cancer treatment center. We conducted a systematic analysis of the RT process that identified four process domains: Assessment, Preparation, Treatment, and Follow-up. For the Preparation domain, we analyzed possible incident scenarios via fault trees. For each task, we also identified existing quality control measures. To populate the fault trees we used subjective probabilities from experts and compared results with incident report data. Both the fault tree and the incident report analysis revealed simulation tasks to be most prone to incidents, and the treatment prescription task to be least prone to incidents. The probability of a Preparation domain incident was estimated to be in the range of 0.1-0.7% based on incident reports, which is comparable to the mean value of 0.4% from the fault tree analysis using probabilities from the expert elicitation exercise. In conclusion, an analysis of part of the RT system using a fault tree populated with subjective probabilities from experts was useful in identifying vulnerable components of the system, and provided quantitative data for risk management.
Collapse
|
48
|
Cooke DL, Dunscombe PB, Lee RC. Using a survey of incident reporting and learning practices to improve organisational learning at a cancer care centre. Qual Saf Health Care 2007; 16:342-8. [PMID: 17913774 PMCID: PMC2464979 DOI: 10.1136/qshc.2006.018754] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To motivate improvements in an organisational system by measuring staff perceptions of the organisation's ability to learn from incidents and by analysing their personal experience of incidents. METHODS Respondents were questioned on the components of the incident learning system from both a personal and an organisational perspective. The respondents (n = 125) were radiotherapists, nurses, dosimetrists, doctors, and other staff at a major academic cancer centre. Responses were analysed in terms of per cent positive responses and response rate, differences between "frontline" and "support" staff, and the respondent's experience with incidents. RESULTS Respondents were more familiar with and more positive about incident identification and reporting--the first two stages of incident learning. Their overall perception of incident learning was most influenced by the investigation and learning components of the system. Respondents in frontline positions were more positive than those in support positions about responding to, identifying and reporting incidents. Respondents reported having experienced a mean of three incidents per year, of which two were reported and two out of three of the reported incidents were investigated, and a median of two incidents being experienced and reported, but none investigated. Most incidents experienced were not captured by the organisation's existing incident reporting system. CONCLUSION The survey tool was effective in measuring the ability of the organisation to learn from incidents. Implications of the survey results for improving organisational learning are discussed.
Collapse
|
49
|
Dunscombe PB, Iftody S, Ploquin N, Ekaette EU, Lee RC. The Equivalent Uniform Dose as a severity metric for radiation treatment incidents. Radiother Oncol 2007; 84:64-6. [PMID: 17586076 DOI: 10.1016/j.radonc.2007.05.024] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2007] [Revised: 05/18/2007] [Accepted: 05/19/2007] [Indexed: 10/23/2022]
Abstract
In allocating resources within a risk management program, ideally we would like to know both the probabilities and consequences of potential incidents. We simulate, on a treatment planning computer, several commonly reported incidents in radiation treatment and explore their consequences for the EUDs of targets and organs at risk.
Collapse
|
50
|
Despa F, Orgill DP, Lee RC. Stability of cellular proteins under supraphysiological temperatures. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:5440-3. [PMID: 17271577 DOI: 10.1109/iembs.2004.1404520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
We present quantitative analyses of the kinetics of cellular components confronted with the destabilizing effect of irreversible thermal denaturation. We examine the dependence of the thermal denaturation on the heating rate, relative stability, population and lifetime of the states involved in transition and crowding effects. We propose a mechanism for self-stabilization of proteins during unfolding in tightly packed fibers and membranes. Speaking in terms of vulnerability to thermal denaturation, our results suggest that the thermal alteration of the plasma membrane is likely to be the most significant cause of the tissue necrosis.
Collapse
|