26
|
Mulkern RV, Tempany CM. In memoriam: Ferenc A. Jolesz (1946-2014). Magn Reson Med 2015; 74:301-2. [PMID: 26077435 DOI: 10.1002/mrm.25777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Revised: 04/24/2015] [Accepted: 04/24/2015] [Indexed: 11/07/2022]
|
27
|
Mitsouras D, Mulkern RV, Maier SE. Multicomponent T2 relaxation studies of the avian egg. Magn Reson Med 2015; 75:2156-64. [PMID: 26037128 DOI: 10.1002/mrm.25762] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 04/09/2015] [Accepted: 04/15/2015] [Indexed: 11/08/2022]
Abstract
PURPOSE To investigate the tissue-like multiexponential T2 signal decays in avian eggs. METHODS Transverse relaxation studies of raw, soft-boiled and hard-boiled eggs were performed at 3 Tesla using a three-dimensional Carr-Purcell-Meiboom-Gill imaging sequence. Signal decays over a TE range of 11 to 354 ms were fitted assuming single- and multicomponent signal decays with up to three separately decaying components. Fat saturation was used to facilitate spectral assignment of observed decay components. RESULTS Egg white, yolk and the centrally located latebra all demonstrate nonmonoexponential T2 decays. Specifically, egg white exhibits two-component decays with intermediate and long T2 times. Meanwhile, yolk and latebra are generally best characterized with triexponential decays, with short, intermediate and very long T2 decay times. Fat saturation revealed that the intermediate component of yolk could be attributed to lipids. Cooking of the egg profoundly altered the decay curves. CONCLUSION Avian egg T2 decay curves cover a wide range of decay times. Observed T2 components in yolk and latebra as short as 10 ms, may prove valuable for testing clinical sequences designed to measure short T2 components, such as myelin-associated water in the brain. Thus we propose that the egg can be a versatile and widely available MR transverse relaxation phantom.
Collapse
|
28
|
Fedorov A, Penzkofer T, Hirsch MS, Flood TA, Vangel MG, Masry P, Tempany CM, Mulkern RV, Fennessy FM. The role of pathology correlation approach in prostate cancer index lesion detection and quantitative analysis with multiparametric MRI. Acad Radiol 2015; 22:548-55. [PMID: 25683501 PMCID: PMC4429788 DOI: 10.1016/j.acra.2014.12.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Revised: 12/30/2014] [Accepted: 12/31/2014] [Indexed: 12/15/2022]
Abstract
Rationale and Objectives Development of imaging biomarkers often relies on their correlation with histopathology. Our aim was to compare two approaches for correlating pathology to multiparametric magnetic resonance (MR) imaging (mpMRI) for localization and quantitative assessment of prostate cancer (PCa) index tumor using whole mount (WM) pathology (WMP) as the reference. Materials and Methods Patients (N = 30) underwent mpMRI that included diffusion-weighted imaging and dynamic contrast-enhanced (DCE) MRI at 3 T before radical prostatectomy (RP). RP specimens were processed using WM technique (WMP) and findings summarized in a standard surgical pathology report (SPR). Histology index tumor volumes (HTVs) were compared to MR tumor volumes (MRTVs) using two approaches for index lesion identification on mpMRI using annotated WMP slides as the reference (WMP) and using routine SPR as the reference. Consistency of index tumor localization, tumor volume, and mean values of the derived quantitative parameters (mean apparent diffusion coefficient [ADC], Ktrans, and ve) were compared. Results Index lesions from 16 of 30 patients met the selection criteria. There was WMP/SRP agreement in index tumor in 13 of 16 patients. ADC-based MRTVs were larger (P < .05) than DCE-based MRTVs. ADC MRTVs were smaller than HTV (P < .005). There was a strong correlation between HTV and MRTV (Pearson r > 0.8; P < .05). No significant differences were observed in the mean values of Ktrans and ADC between the WMP and SPR. Conclusions WMP correlation is superior to SPR for accurate localization of all index lesions. The use of WMP is however not required to distinguish significant differences of mean values of quantitative MRI parameters within tumor volume.
Collapse
|
29
|
Mulkern RV, Ricci KI, Vajapeyam S, Chenevert TL, Malyarenko DI, Kocak M, Poussaint TY. Pediatric brain tumor consortium multisite assessment of apparent diffusion coefficient z-axis variation assessed with an ice-water phantom. Acad Radiol 2015; 22:363-9. [PMID: 25435183 DOI: 10.1016/j.acra.2014.10.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 10/09/2014] [Accepted: 10/11/2014] [Indexed: 11/16/2022]
Abstract
RATIONALE AND OBJECTIVES Magnetic resonance diffusion imaging can characterize physiologic characteristics of pediatric brain tumors used to assess therapy response. The purpose of this study was to assess the variability of the apparent diffusion coefficient (ADC) along z-axis of scanners in the multicenter Pediatric Brain Tumor Consortium (PBTC). MATERIALS AND METHODS Ice-water diffusion phantoms for each PBTC site were distributed with a specific diffusion imaging protocol. The phantom was scanned four successive times to 1) confirm water in the tube reached thermal equilibrium and 2) allow for assessment of intra-examination ADC repeatability. ADC profiles across slice positions for each vendor and institution combination were characterized using linear regression modeling with a quadratic fit. RESULTS Eleven sites collected data with a high degree of compliance to the diffusion protocol for each scanner. The mean ADC value at slice position zero for vendor A was 1.123 × 10(-3) mm(2)/s, vendor B was 1.0964 × 10(-3) mm(2)/s, and vendor C was 1.110 × 10(-3) mm(2)/s. The percentage coefficient of variation across all sites was 0.309% (standard deviation = 0.322). The ADC values conformed well to a second-order polynomial along the z-axis, (ie, following a linear model pattern with quadratic fit) for vendor-institution combinations and across vendor-institution combinations as shown in the longitudinal model. CONCLUSIONS Assessment of the variability of diffusion metrics is essential for establishing the validity of using these quantitative metrics in multicenter trials. The low variability in ADC values across vendors and institutions and validates the use of ADC as a quantitative tumor marker in pediatric multicenter trials.
Collapse
|
30
|
Yamauchi FI, Penzkofer T, Fedorov A, Fennessy FM, Chu R, Maier SE, Tempany CMC, Mulkern RV, Panych LP. Prostate cancer discrimination in the peripheral zone with a reduced field-of-view T(2)-mapping MRI sequence. Magn Reson Imaging 2015; 33:525-30. [PMID: 25687187 DOI: 10.1016/j.mri.2015.02.006] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Revised: 01/15/2015] [Accepted: 02/08/2015] [Indexed: 10/24/2022]
Abstract
OBJECTIVES To evaluate the performance of T2 mapping in discriminating prostate cancer from normal prostate tissue in the peripheral zone using a practical reduced field-of-view MRI sequence requiring less than 3 minutes of scan time. MATERIALS AND METHODS Thirty-six patients with biopsy-proven peripheral zone prostate cancer without prior treatment underwent routine multiparametric MRI at 3.0T with an endorectal coil. An Inner-Volume Carr-Purcell-Meiboom-Gill imaging sequence that required 2.8 minutes to obtain data for quantitative T2 mapping covering the entire prostate gland was added to the routine multiparametric protocol. Suspected cancer (SC) and suspected healthy (SH) tissue in the peripheral zone were identified in consensus by three radiologists and were correlated with available biopsy results. Differences in mean T2 values in SC and SH regions-of-interest (ROIs) were tested for significance using unpaired Student's two-tailed t-test. The area under the receiver operating characteristic curve was used to assess the optimal threshold T2 value for cancer discrimination. RESULTS ROI analyses revealed significantly (p<0.0001) shorter T2 values in SC (85.4±12.3ms) compared to SH (169.6±38.7ms). An estimated T2 threshold of 99ms yielded a sensitivity of 92% and a specificity of 97% for prostate cancer discrimination. CONCLUSIONS Quantitative values derived from this clinically practical T2-mapping sequence allow high precision discrimination between healthy and cancerous peripheral zone in the prostate.
Collapse
|
31
|
Gholipour A, Estroff JA, Barnewolt CE, Robertson RL, Grant PE, Gagoski B, Warfield SK, Afacan O, Connolly SA, Neil JJ, Wolfberg A, Mulkern RV. Fetal MRI: A Technical Update with Educational Aspirations. CONCEPTS IN MAGNETIC RESONANCE. PART A, BRIDGING EDUCATION AND RESEARCH 2014; 43:237-266. [PMID: 26225129 PMCID: PMC4515352 DOI: 10.1002/cmr.a.21321] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Fetal magnetic resonance imaging (MRI) examinations have become well-established procedures at many institutions and can serve as useful adjuncts to ultrasound (US) exams when diagnostic doubts remain after US. Due to fetal motion, however, fetal MRI exams are challenging and require the MR scanner to be used in a somewhat different mode than that employed for more routine clinical studies. Herein we review the techniques most commonly used, and those that are available, for fetal MRI with an emphasis on the physics of the techniques and how to deploy them to improve success rates for fetal MRI exams. By far the most common technique employed is single-shot T2-weighted imaging due to its excellent tissue contrast and relative immunity to fetal motion. Despite the significant challenges involved, however, many of the other techniques commonly employed in conventional neuro- and body MRI such as T1 and T2*-weighted imaging, diffusion and perfusion weighted imaging, as well as spectroscopic methods remain of interest for fetal MR applications. An effort to understand the strengths and limitations of these basic methods within the context of fetal MRI is made in order to optimize their use and facilitate implementation of technical improvements for the further development of fetal MR imaging, both in acquisition and post-processing strategies.
Collapse
|
32
|
Balasubramanian M, Mulkern RV, Wells WM, Sundaram P, Orbach DB. Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow. Magn Reson Med 2014; 74:1145-55. [PMID: 25273917 DOI: 10.1002/mrm.25445] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Revised: 07/25/2014] [Accepted: 08/15/2014] [Indexed: 11/06/2022]
Abstract
PURPOSE Reliably detecting MRI signals in the brain that are more tightly coupled to neural activity than blood-oxygen-level-dependent fMRI signals could not only prove valuable for basic scientific research but could also enhance clinical applications such as epilepsy presurgical mapping. This endeavor will likely benefit from an improved understanding of the behavior of ionic currents, the mediators of neural activity, in the presence of the strong magnetic fields that are typical of modern-day MRI scanners. THEORY Of the various mechanisms that have been proposed to explain the behavior of ionic volume currents in a magnetic field, only one-magnetohydrodynamic flow-predicts a slow evolution of signals, on the order of a minute for normal saline in a typical MRI scanner. METHODS This prediction was tested by scanning a volume-current phantom containing normal saline with gradient-echo-planar imaging at 3 T. RESULTS Greater signal changes were observed in the phase of the images than in the magnitude, with the changes evolving on the order of a minute. CONCLUSION These results provide experimental support for the MHD flow hypothesis. Furthermore, MHD-driven cerebrospinal fluid flow could provide a novel fMRI contrast mechanism.
Collapse
|
33
|
Penzkofer T, Tuncali K, Fedorov A, Song SE, Tokuda J, Fennessy FM, Vangel MG, Kibel AS, Mulkern RV, Wells WM, Hata N, Tempany CMC. Transperineal in-bore 3-T MR imaging-guided prostate biopsy: a prospective clinical observational study. Radiology 2014; 274:170-80. [PMID: 25222067 DOI: 10.1148/radiol.14140221] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE To determine the detection rate, clinical relevance, Gleason grade, and location of prostate cancer ( PCa prostate cancer ) diagnosed with and the safety of an in-bore transperineal 3-T magnetic resonance (MR) imaging-guided prostate biopsy in a clinically heterogeneous patient population. MATERIALS AND METHODS This prospective retrospectively analyzed study was HIPAA compliant and institutional review board approved, and informed consent was obtained. Eighty-seven men (mean age, 66.2 years ± 6.9) underwent multiparametric endorectal prostate MR imaging at 3 T and transperineal MR imaging-guided biopsy. Three subgroups of patients with at least one lesion suspicious for cancer were included: men with no prior PCa prostate cancer diagnosis, men with PCa prostate cancer who were undergoing active surveillance, and men with treated PCa prostate cancer and suspected recurrence. Exclusion criteria were prior prostatectomy and/or contraindication to 3-T MR imaging. The transperineal MR imaging-guided biopsy was performed in a 70-cm wide-bore 3-T device. Overall patient biopsy outcomes, cancer detection rates, Gleason grade, and location for each subgroup were evaluated and statistically compared by using χ(2) and one-way analysis of variance followed by Tukey honestly significant difference post hoc comparisons. RESULTS Ninety biopsy procedures were performed with no serious adverse events, with a mean of 3.7 targets sampled per gland. Cancer was detected in 51 (56.7%) men: 48.1% (25 of 52) with no prior PCa prostate cancer , 61.5% (eight of 13) under active surveillance, and 72.0% (18 of 25) in whom recurrence was suspected. Gleason pattern 4 or higher was diagnosed in 78.1% (25 of 32) in the no prior PCa prostate cancer and active surveillance groups. Gleason scores were not assigned in the suspected recurrence group. MR targets located in the anterior prostate had the highest cancer yield (40 of 64, 62.5%) compared with those for the other parts of the prostate (P < .001). CONCLUSION In-bore 3-T transperineal MR imaging-guided biopsy, with a mean of 3.7 targets per gland, allowed detection of many clinically relevant cancers, many of which were located anteriorly.
Collapse
|
34
|
Shinmoto H, Oshio K, Tamura C, Soga S, Okamura T, Yamada K, Kaji T, Mulkern RV. Diffusion-weighted imaging of prostate cancer using a statistical model based on the gamma distribution. J Magn Reson Imaging 2014; 42:56-62. [DOI: 10.1002/jmri.24761] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Accepted: 09/02/2014] [Indexed: 01/24/2023] Open
|
35
|
Mulkern RV, Balasubramanian M, Mitsouras D. On the lorentzian versus Gaussian character of time-domain spin-echo signals from the brain as sampled by means of gradient-echoes: Implications for quantitative transverse relaxation studies. Magn Reson Med 2014; 74:51-62. [PMID: 25078089 DOI: 10.1002/mrm.25365] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2014] [Revised: 06/19/2014] [Accepted: 06/24/2014] [Indexed: 11/09/2022]
Abstract
PURPOSE To determine whether Lorentzian or Gaussian intra-voxel frequency distributions are better suited for modeling data acquired with gradient-echo sampling of single spin-echoes for the simultaneous characterization of irreversible and reversible relaxation rates. Clinical studies (e.g., of brain iron deposition) using such acquisition schemes have typically assumed Lorentzian distributions. THEORY AND METHODS Theoretical expressions of the time-domain spin-echo signal for intra-voxel Lorentzian and Gaussian distributions were used to fit data from a human brain scanned at both 1.5 Tesla (T) and 3T, resulting in maps of irreversible and reversible relaxation rates for each model. The relative merits of the Lorentzian versus Gaussian model were compared by means of quality of fit considerations. RESULTS Lorentzian fits were equivalent to Gaussian fits primarily in regions of the brain where irreversible relaxation dominated. In the multiple brain regions where reversible relaxation effects become prominent, however, Gaussian fits were clearly superior. CONCLUSION The widespread assumption that a Lorentzian distribution is suitable for quantitative transverse relaxation studies of the brain should be reconsidered, particularly at 3T and higher field strengths as reversible relaxation effects become more prominent. Gaussian distributions offer alternate fits of experimental data that should prove quite useful in general. Magn Reson Med 74:51-62, 2015. © 2014 Wiley Periodicals, Inc.
Collapse
|
36
|
Akhondi-Asl A, Afacan O, Mulkern RV, Warfield SK. T(2)-relaxometry for myelin water fraction extraction using wald distribution and extended phase graph. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2014; 17:145-52. [PMID: 25320793 PMCID: PMC4209472 DOI: 10.1007/978-3-319-10443-0_19] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
Abstract
Quantitative assessment of myelin density in the white matter is an emerging tool for neurodegenerative disease related studies such as multiple sclerosis and Schizophrenia. For the last two decades, T2 relaxometry based on multi-exponential fitting to a single slice multi-echo sequence has been the most common MRI technique for myelin water fraction (MWF) mapping, where the short T2 is associated with myelin water. However, modeling the spectrum of the relaxations as the sum of large number of impulse functions with unknown amplitudes makes the accuracy and robustness of the estimated MWF's questionable. In this paper, we introduce a novel model with small number of parameters to simultaneously characterize transverse relaxation rate spectrum and B1 inhomogeneity at each voxel. We use mixture of three Wald distributions with unknown mixture weights, mean and shape parameters to represent the distribution of the relative amount of water in between myelin sheets, tissue water, and cerebrospinal fluid. The parameters of the model are estimated using the variable projection method and are used to extract the MWF at each voxel. In addition, we use Extended Phase Graph (EPG) method to compensate for the stimulated echoes caused by B1 inhomogeneity. To validate our model, synthetic and real brain experiments were conducted where we have compared our novel algorithm with the non-negative least squares (NNLS) as the state-of-the-art technique in the literature. Our results indicate that we can estimate MWF map with substantially higher accuracy as compared to the NNLS method.
Collapse
|
37
|
Hegde JV, Mulkern RV, Panych LP, Fennessy FM, Fedorov A, Maier SE, Tempany CMC. Multiparametric MRI of prostate cancer: an update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J Magn Reson Imaging 2013; 37:1035-54. [PMID: 23606141 DOI: 10.1002/jmri.23860] [Citation(s) in RCA: 170] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2011] [Accepted: 09/04/2012] [Indexed: 12/15/2022] Open
Abstract
Magnetic resonance (MR) examinations of men with prostate cancer are most commonly performed for detecting, characterizing, and staging the extent of disease to best determine diagnostic or treatment strategies, which range from biopsy guidance to active surveillance to radical prostatectomy. Given both the exam's importance to individual treatment plans and the time constraints present for its operation at most institutions, it is essential to perform the study effectively and efficiently. This article reviews the most commonly employed modern techniques for prostate cancer MR examinations, exploring the relevant signal characteristics from the different methods discussed and relating them to intrinsic prostate tissue properties. Also, a review of recent articles using these methods to enhance clinical interpretation and assess clinical performance is provided. J. Magn. Reson. Imaging 2013;37:1035-1054. © 2013 Wiley Periodicals, Inc.
Collapse
|
38
|
Maier SE, Mitsouras D, Mulkern RV. Avian egg latebra as brain tissue water diffusion model. Magn Reson Med 2013; 72:501-9. [PMID: 24105853 DOI: 10.1002/mrm.24941] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Revised: 07/18/2013] [Accepted: 08/13/2013] [Indexed: 11/08/2022]
Abstract
PURPOSE Simplified models of non-monoexponential diffusion signal decay are of great interest to study the basic constituents of complex diffusion behavior in tissues. The latebra, a unique structure uniformly present in the yolk of avian eggs, exhibits a non-monoexponential diffusion signal decay. This model is more complex than simple phantoms based on differences between water and lipid diffusion, but is also devoid of microscopic structures with preferential orientation or perfusion effects. METHODS Diffusion scans with multiple b-values were performed on a clinical 3 Tesla system in raw and boiled chicken eggs equilibrated to room temperature. Diffusion encoding was applied over the ranges 5-5,000 and 5-50,000 s/mm(2). A low read-out bandwidth and chemical shift was used for reliable lipid/water separation. Signal decays were fitted with exponential functions. RESULTS The latebra, when measured over the 5-5,000 s/mm(2) range, exhibited independent of preparation clearly biexponential diffusion, with diffusion parameters similar to those typically observed in in vivo human brain. For the range 5-50,000 s/mm(2), there was evidence of a small third, very slow diffusing water component. CONCLUSION The latebra of the avian egg contains membrane structures, which may explain a deviation from a simple monoexponential diffusion signal decay, which is remarkably similar to the deviation observed in brain tissue.
Collapse
|
39
|
Ramon-Krauel M, Salsberg SL, Ebbeling CB, Voss SD, Mulkern RV, Apura MM, Cooke EA, Sarao K, Jonas MM, Ludwig DS. A low-glycemic-load versus low-fat diet in the treatment of fatty liver in obese children. Child Obes 2013; 9:252-60. [PMID: 23705885 PMCID: PMC3675832 DOI: 10.1089/chi.2013.0022] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Fatty liver is highly prevalent among obese children and represents a major risk factor for chronic liver diseases and severe metabolic complications. METHODS We randomly assigned 17 obese children 8-17 years of age with fatty liver to either an experimental low-glycemic-load or conventional low-fat diet for 6 months. Participants in both groups received nutrition education and behavioral counseling of equal intensity. The primary outcome was hepatic lipid content measured by proton magnetic resonance spectroscopy. Secondary outcomes included change in visceral fat, BMI, anthropometrics, alanine aminotransferase (ALT), and insulin resistance. RESULTS A total of 16 participants completed the study. Reported glycemic load decreased in the low-glycemic-load group and reported dietary fat decreased in the low-fat group. At baseline, liver fat was 23.8% [standard deviation (SD) 12.2] in the low-glycemic-load group and 29.3% (14.1) in the low-fat group. Liver fat decreased substantially in both groups at 6 months expressed as absolute percentage change, with no between-group differences [-8.8 (standard error (SE) 4.1) vs. -10.5 (3.7)%, respectively, p=0.76 for group×time interaction]. Secondary outcomes also improved on both diets, with no between-group differences. Baseline and change in ALT were strongly associated with hepatic fat content. CONCLUSIONS Weight-reducing diets focused either on glycemic load or dietary fat improved hepatic steatosis over 6 months. Additional research is needed to determine whether these diets differ in effectiveness over the long term. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00480922.
Collapse
|
40
|
Panych LP, Roebuck JR, Chen NK, Tang Y, Madore B, Tempany CM, Mulkern RV. Investigation of the PSF-choice method for reduced lipid contamination in prostate MR spectroscopic imaging. Magn Reson Med 2013; 68:1376-82. [PMID: 22648701 DOI: 10.1002/mrm.24132] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of this work was to evaluate a previously proposed approach that aims to improve the point spread function (PSF) of MR spectroscopic imaging (MRSI) to avoid corruption by lipid signal arising from neighboring voxels. Retrospective spatial filtering can be used to alter the PSF; however, this either reduces spatial resolution or requires extending the acquisition in k-space at the cost of increased imaging time. Alternatively, the method evaluated here, PSF-choice, can modify the PSF localization to reduce the contamination from adjacent lipids by conforming the signal response more closely to the desired MRSI voxel grid. This is done without increasing scan time or degrading SNR of important metabolites. PSF-choice achieves improvements in spatial localization through modifications to the radiofrequency excitation pulses. An implementation of this method is reported for MRSI of the prostate, where it is demonstrated that, in 13 of 16 pilot prostate MRSI scans, intravoxel spectral contamination from lipid was significantly reduced when using PSF-choice. Phantom studies were also performed that demonstrate, compared with MRSI with standard Fourier phase encoding, out-of-voxel signal contamination of spectra was significantly reduced in MRSI with PSF-choice.
Collapse
|
41
|
Gambarota G, Bondon A, Le Floch M, Mulkern RV, Saint-Jalmes H. Selective spectral modulation of strongly coupled spins with an echo top refocusing pulse in PRESS sequences. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 228:76-80. [PMID: 23357429 DOI: 10.1016/j.jmr.2012.12.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Revised: 12/20/2012] [Accepted: 12/21/2012] [Indexed: 06/01/2023]
Abstract
The double spin echo is the basis of the point resolved spectroscopy (PRESS) sequence. In this study we sought to investigate the effects of a broadband 180° pulse - incorporated in the PRESS sequence at the location of the first echo (gPRESS) - on the citrate resonances, chosen as a model of strongly coupled spin system. A significant signal modulation generated by the additional 180° pulse was predicted with simulations and observed experimentally in the citrate resonances. No effects were observed on the singlet resonance of glycine and the weakly coupled resonances of lactate. The phenomenon observed in gPRESS was attributed to the off-diagonal Hamiltonian elements responsible for a coherence transfer occurring throughout the evolution periods. The results of this study show that it is necessary to assess the effects of broadband 180° pulses on strongly coupled spin systems, since these pulses can selectively modify the spectral shape of strongly coupled resonances.
Collapse
|
42
|
Freiman M, Afacan O, Mulkern RV, Warfield SK. Improved multi B-value diffusion-weighted MRI of the body by simultaneous model estimation and image reconstruction (SMEIR). MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2013; 16:1-8. [PMID: 24505737 PMCID: PMC4029838 DOI: 10.1007/978-3-642-40760-4_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Diffusion-weighted MRI images acquired with multiple b-values have the potential to improve diagnostic accuracy by increasing the conspicuity of lesions and inflammatory activity with background suppression. Unfortunately, the inherently low signal-to-noise ratio (SNR) of DW-MRI reduces enthusiasm for using these images for diagnostic purposes. Moreover, lengthy acquisition times limit our ability to improve the quality of multi b-value DW-MRI images by multiple excitations acquisition and signal averaging at each b-value. To offset these limitations, we propose the Simultaneous Model Estimation and Image Reconstruction (SMEIR) for DW-MRI, which substantially improves the quality of multi b-value DW-MRI images without increasing acquisition times. Our model introduces the physiological signal decay model of DW-MRI as a constraint in the reconstruction of the DW-MRI images. An in-vivo experiment using 6 low-quality DW-MRI datasets of a healthy subject showed that SMEIR reconstruction of low-quality data improved SNR by 55% in the liver and by 41% in the kidney without increasing acquisition times. We also demonstrated the clinical impact of our SMEIR reconstruction by increasing the conspicuity of inflamed bowel regions in DW-MRI of 12 patients with Crohn's disease. The contrast-to-noise ratio (CNR) of the inflamed regions in the SMEIR images was higher by 12.6% relative to CNR in the original DW-MRI images.
Collapse
|
43
|
Hegde JV, Chen MH, Mulkern RV, Fennessy FM, D'Amico AV, Tempany CMC. Preoperative 3-Tesla multiparametric endorectal magnetic resonance imaging findings and the odds of upgrading and upstaging at radical prostatectomy in men with clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 2012; 85:e101-7. [PMID: 23040223 DOI: 10.1016/j.ijrobp.2012.08.032] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2012] [Revised: 08/16/2012] [Accepted: 08/20/2012] [Indexed: 01/01/2023]
Abstract
PURPOSE To investigate whether 3-T esla (3T) multiparametric endorectal MRI (erMRI) can add information to established predictors regarding occult extraprostatic or high-grade prostate cancer (PC) in men with clinically localized PC. METHODS AND MATERIALS At a single academic medical center, this retrospective study's cohort included 118 men with clinically localized PC who underwent 3T multiparametric erMRI followed by radical prostatectomy, from 2008 to 2011. Multivariable logistic regression analyses in all men and in 100 with favorable-risk PC addressed whether erMRI evidence of T3 disease was associated with prostatectomy T3 or Gleason score (GS) 8-10 (in patients with biopsy GS ≤7) PC, adjusting for age, prostate-specific antigen level, clinical T category, biopsy GS, and percent positive biopsies. RESULTS The accuracy of erMRI prediction of extracapsular extension and seminal vesicle invasion was 75% and 95%, respectively. For all men, erMRI evidence of a T3 lesion versus T2 was associated with an increased odds of having pT3 disease (adjusted odds ratio [AOR] 4.81, 95% confidence interval [CI] 1.36-16.98, P=.015) and pGS 8-10 (AOR 5.56, 95% CI 1.10-28.18, P=.038). In the favorable-risk population, these results were AOR 4.14 (95% CI 1.03-16.56), P=.045 and AOR 7.71 (95% CI 1.36-43.62), P=.021, respectively. CONCLUSIONS Three-Tesla multiparametric erMRI in men with favorable-risk PC provides information beyond that contained in known preoperative predictors about the presence of occult extraprostatic and/or high-grade PC. If validated in additional studies, this information can be used to counsel men planning to undergo radical prostatectomy or radiation therapy about the possible need for adjuvant radiation therapy or the utility of adding hormone therapy, respectively.
Collapse
|
44
|
Freiman M, Voss SD, Mulkern RV, Perez-Rossello JM, Callahan MJ, Warfield SK. In vivo assessment of optimal b-value range for perfusion-insensitive apparent diffusion coefficient imaging. Med Phys 2012; 39:4832-9. [PMID: 22894409 DOI: 10.1118/1.4736516] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess the optimal b-values range for perfusion-insensitive apparent diffusion coefficient (ADC) imaging of abdominal organs using short-duration DW-MRI acquisitions with currently available ADC estimation methods. METHODS DW-MRI data of 15 subjects were acquired with eight b-values in the range of 5-800 s∕mm(2). The reference-standard, a perfusion insensitive, ADC value (ADC(IVIM)), was computed using an intravoxel incoherent motion (IVIM) model with all acquired diffusion-weighted images. Simulated DW-MRI data was generated using an IVIM model with b-values in the range of 0-1200 s∕mm(2). Monoexponential ADC estimates were calculated using: (1) Two-point estimator (ADC(2)); (2) least squares three-point (ADC(3)) estimator and; (3) Rician noise model estimator (ADC(R)). The authors found the optimal b-values for perfusion-insensitive ADC calculations by minimizing the relative root mean square error (RRMS) between the ADC(IVIM) and the monoexponential ADC values for each estimation method and organ. RESULTS Low b-value = 300 s∕mm(2) and high b-value = 1200 s∕mm(2) minimized the RRMS between the estimated ADC and the reference-standard ADC(IVIM) to less than 5% using the ADC(3) estimator. By considering only the in vivo DW-MRI data, the combination of low b-value = 270 s∕mm(2) and high b-value of 800 s∕mm(2) minimized the RRMS between the estimated ADC and the reference-standard ADC(IVIM) to <7% using the ADC(3) estimator. For all estimators, the RRMS between the estimated ADC and the reference standard ADC correlated strongly with the perfusion-fraction parameter of the IVIM model (r = [0.78-0.83], p ≤ 0.003). CONCLUSIONS The perfusion compartment in DW-MRI signal decay correlates strongly with the RRMS in ADC estimates from short-duration DW-MRI. The impact of the perfusion compartment on ADC estimations depends, however, on the choice of b-values and estimation method utilized. Likewise, perfusion-related errors can be reduced to <7% by carefully selecting the b-values used for ADC calculations and method of estimation.
Collapse
|
45
|
Freiman M, Perez-Rossello JM, Callahan MJ, Bittman M, Mulkern RV, Bousvaros A, Warfield SK. Characterization of fast and slow diffusion from diffusion-weighted MRI of pediatric Crohn's disease. J Magn Reson Imaging 2012; 37:156-63. [PMID: 22927342 DOI: 10.1002/jmri.23781] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 07/20/2012] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To characterize fast and slow diffusion components in diffusion-weighted magnetic resonance imaging (DW-MRI) of pediatric Crohn's disease (CD). Overall diffusivity reduction as measured by the apparent diffusion coefficient (ADC) in patients with CD has been previously demonstrated. However, the ADC reduction may be due to changes in either fast or slow diffusion components. In this study we distinguished between the fast and slow diffusion components in the DW-MRI signal decay of pediatric CD. MATERIALS AND METHODS We acquired MRI from 24 patients, including MR enterography (MRE) and DW-MRI with 8 b-values (0-800 s/mm(2)). We characterized fast and slow diffusivity by intravoxel incoherent motion (IVIM) model parameters (f, D*, D), and overall diffusivity by ADC values. We determined which model best described the DW-MRI signal decay. We assessed the influence of the IVIM model parameters on the ADC. We evaluated differences in model parameter values between the enhancing and nonenhancing groups. RESULTS The IVIM model described the observed data significantly better than the ADC model (P = 0.0088). The ADC was correlated with f (r = 0.67, P = 0.0003), but not with D (r = 0.39, P = 0.062) and D* (r = -0.39, P = 0.057). f values were significantly lower (P < 0.003) and D* values were significantly higher (P = 0.03) in the enhancing segments, while D values were not significantly different between the groups (P = 0.14). CONCLUSION For this study population the IVIM model provides a better description of the DW-MRI signal decay than the ADC model. The reduced ADC is related to changes in the fast diffusion rather than to changes in the slow diffusion.
Collapse
|
46
|
Fennessy FM, Fedorov A, Gupta SN, Schmidt EJ, Tempany CM, Mulkern RV. Practical considerations in T1 mapping of prostate for dynamic contrast enhancement pharmacokinetic analyses. Magn Reson Imaging 2012; 30:1224-33. [PMID: 22898681 DOI: 10.1016/j.mri.2012.06.011] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Revised: 06/08/2012] [Accepted: 06/16/2012] [Indexed: 12/23/2022]
Abstract
There are many challenges in developing robust imaging biomarkers that can be reliably applied in a clinical trial setting. In the case of dynamic contrast-enhanced (DCE) MRI, one such challenge is to obtain accurate precontrast T(1) maps for subsequent use in two-compartment pharmacokinetic models commonly used to fit the MR enhancement time courses. In the prostate, a convenient and common approach for this task has been to use the same 3D spoiled gradient-echo sequence used to collect the DCE data, but with variable flip angles (VFAs) to collect data suitable for T(1) mapping prior to contrast injection. However, inhomogeneous radiofrequency conditions within the prostate have been found to adversely affect the accuracy of this technique. Herein we demonstrate the sensitivity of DCE pharmacokinetic parameters to precontrast T(1) values and examine methods to improve the accuracy of T(1) mapping with flip angle-corrected VFA SPGR methods, comparing T(1) maps from such methods with "gold standard" reference T(1) maps generated with saturation recovery experiments performed with fast spin-echo (FSE) sequences.
Collapse
|
47
|
Freiman M, Voss SD, Mulkern RV, Perez-Rossello JM, Callahan MJ, Warfield SK. Reliable assessment of perfusivity and diffusivity from diffusion imaging of the body. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2012; 15:1-9. [PMID: 23285528 DOI: 10.1007/978-3-642-33415-3_1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Diffusion-weighted MRI of the body has the potential to provide important new insights into physiological and microstructural properties. The intra-voxel incoherent motion (IVIM) model relates the observed DW-MRI signal decay to parameters that reflect perfusivity (D*) and its volume fraction (f), and diffusivity (D). However, the commonly used voxel-wise fitting of the IVIM model leads to parameter estimates with poor precision, which has hampered their practical usage. In this work, we increase the estimates' precision by introducing a model of spatial homogeneity, through which we obtain estimates of model parameters for all of the voxels at once, instead of solving for each voxel independently. Furthermore, we introduce an efficient iterative solver which utilizes a model-based bootstrap estimate of the distribution of residuals and a binary graph cut to generate optimal model parameter updates. Simulation experiments show that our approach reduces the relative root mean square error of the estimated parameters by 80% for the D* parameter and by 50% for the f and D parameters. We demonstrated the clinical impact of our model in distinguishing between enhancing and nonenhancing ileum segments in 24 Crohn's disease patients. Our model detected the enhanced segments with 91%/92% sensitivity/specificity which is better than the 81%/85% obtained by the voxel-independent approach.
Collapse
|
48
|
Freiman M, Voss SD, Mulkern RV, Perez-Rossello JM, Warfield SK. Quantitative body DW-MRI biomarkers uncertainty estimation using unscented wild-bootstrap. ACTA ACUST UNITED AC 2011; 14:74-81. [PMID: 21995015 DOI: 10.1007/978-3-642-23629-7_10] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2023]
Abstract
We present a new method for the uncertainty estimation of diffusion parameters for quantitative body DW-MRI assessment. Diffusion parameters uncertainty estimation from DW-MRI is necessary for clinical applications that use these parameters to assess pathology. However, uncertainty estimation using traditional techniques requires repeated acquisitions, which is undesirable in routine clinical use. Model-based bootstrap techniques, for example, assume an underlying linear model for residuals rescaling and cannot be utilized directly for body diffusion parameters uncertainty estimation due to the non-linearity of the body diffusion model. To offset this limitation, our method uses the Unscented transform to compute the residuals rescaling parameters from the non-linear body diffusion model, and then applies the wild-bootstrap method to infer the body diffusion parameters uncertainty. Validation through phantom and human subject experiments shows that our method identify the regions with higher uncertainty in body DWI-MRI model parameters correctly with realtive error of -36% in the uncertainty values.
Collapse
|
49
|
Yikilmaz A, Koc A, Coskun A, Ozturk MK, Mulkern RV, Lee EY. Evaluation of pneumonia in children: comparison of MRI with fast imaging sequences at 1.5T with chest radiographs. Acta Radiol 2011; 52:914-9. [PMID: 21816896 DOI: 10.1258/ar.2011.100429] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Although there has been a study aimed at magnetic resonance imaging (MRI) evaluation of pneumonia in children at a low magnetic field (0.2T), there is no study which assessed the efficacy of MRI, particularly with fast imaging sequences at 1.5T, for evaluating pneumonia in children. PURPOSE To investigate the efficacy of chest MRI with fast imaging sequences at 1.5T for evaluating pneumonia in children by comparing MRI findings with those of chest radiographs. MATERIAL AND METHODS This was an Institutional Review Board-approved, HIPPA-compliant prospective study of 40 consecutive pediatric patients (24 boys, 16 girls; mean age 7.3 years ± 6.6 years) with pneumonia, who underwent PA and lateral chest radiographs followed by MRI within 24 h. All MRI studies were obtained in axial and coronal planes with two different fast imaging sequences: T1-weighted FFE (Fast Field Echo) (TR/TE: 83/4.6) and T2-weigthed B-FFE M2D (Balanced Fast Field Echo Multiple 2D Dimensional) (TR/TE: 3.2/1.6). Two experienced pediatric radiologists reviewed each chest radiograph and MRI for the presence of consolidation, necrosis/abscess, bronchiectasis, and pleural effusion. Chest radiograph and MRI findings were compared with Kappa statistics. RESULTS All consolidation, lung necrosis/abscess, bronchiectasis, and pleural effusion detected with chest radiographs were also detected with MRI. There was statistically substantial agreement between chest radiographs and MRI in detecting consolidation (k = 0.78) and bronchiectasis (k = 0.72) in children with pneumonia. The agreement between chest radiographs and MRI was moderate for detecting necrosis/abscess (k = 0.49) and fair for detecting pleural effusion (k = 0.30). CONCLUSION MRI with fast imaging sequences is comparable to chest radiographs for evaluating underlying pulmonary consolidation, bronchiectasis, necrosis/abscess, and pleural effusion often associated with pneumonia in children.
Collapse
|
50
|
Gambarota G, Tanner M, van der Graaf M, Mulkern RV, Newbould RD. 1H-MRS of hepatic fat using short TR at 3T: SNR optimization and fast T2 relaxometry. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2011; 24:339-45. [PMID: 21892734 DOI: 10.1007/s10334-011-0278-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2011] [Revised: 08/11/2011] [Accepted: 08/11/2011] [Indexed: 01/02/2023]
Abstract
OBJECT To increase the signal-to-noise ratio (SNR) efficiency of hepatic fat signals in proton magnetic resonance spectroscopy (1H MRS) at 3 T, in order to improve the quantitation of hepatic fat and allow fast, single breath-hold T2 relaxometry of hepatic water and fat. MATERIALS AND METHODS Since the T1 of lipid protons is relatively short, we hypothesized that it could be possible to increase the lipid SNR efficiency by choosing a TR shorter than that typically employed (≥1.5 s). The lipid SNR per unit-time was calculated using published values of lipid (CH2)n protons' T1 at 3 T. 1H MRS PRESS spectra were acquired from VOIs located in the right lobe of the liver in 28 healthy volunteers. At the short TR of 0.6 s, fast T2 relaxometry with the acquisition of 16 echo times (30, 40, ..., 180 ms), was performed in a single breath-hold measurement using a modified PRESS sequence. RESULTS Good agreement was observed between simulated and experimental data, with the shortening of TR to 0.6 s yielding an ~50% SNR improvement of hepatic lipid (CH2)n resonances, compared to the SNR at TR=2 s. The T2 relaxation time of water and lipid (CH2)n protons at 3 T was 25.8±1.1 ms and 55.4±3.9 ms, respectively, across five healthy volunteers. CONCLUSION The short-TR approach allows for an improved SNR efficiency of lipids and for fast T2 relaxometry of hepatic water and fat, with a detailed coverage of the T2 relaxation decay curve, within a single breath-hold experiment.
Collapse
|