26
|
Schulze Greiving VC, de Boer HL, Bomer JG, van den Berg A, Le Gac S. Integrated microfluidic biosensing platform for simultaneous confocal microscopy and electrophysiological measurements on bilayer lipid membranes and ion channels. Electrophoresis 2017; 39:496-503. [PMID: 29193178 DOI: 10.1002/elps.201700346] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 11/04/2017] [Accepted: 11/05/2017] [Indexed: 01/19/2023]
Abstract
Combining high-resolution imaging and electrophysiological recordings is key for various types of experimentation on lipid bilayers and ion channels. Here, we propose an integrated biosensing platform consisting of a microfluidic cartridge and a dedicated chip-holder to conduct such dual measurements on suspended lipid bilayers, in a user-friendly manner. To illustrate the potential of the integrated platform, we characterize lipid bilayers in terms of thickness and fluidity while simultaneously monitoring single ion channel currents. For that purpose, POPC lipid bilayers are supplemented with a fluorescently-tagged phospholipid (NBD-PE, 1% mol) for Fluorescence Recovery After Photobleaching (FRAP) measurements and a model ion channel (gramicidin, 1 nM). These combined measurements reveal that NBD-PE has no effect on the lipid bilayer thickness while gramicidin induces thinning of the membrane. Furthermore, the presence of gramicidin does not alter the lipid bilayer fluidity. Surprisingly, in lipid bilayers supplemented with both probes, a reduction in gramicidin open probability and lifetime is observed compared to lipid bilayers with gramicidin only, suggesting an influence of NBD-PE on the gramicidin ion function. Altogether, our proposed microfluidic biosensing platform in combination with the herein presented multi-parametric measurement scheme paves the way to explore the interdependent relationship between lipid bilayer properties and ion channel function.
Collapse
|
27
|
Virumbrales-Muñoz M, Ayuso JM, Olave M, Monge R, de Miguel D, Martínez-Lostao L, Le Gac S, Doblare M, Ochoa I, Fernandez LJ. Multiwell capillarity-based microfluidic device for the study of 3D tumour tissue-2D endothelium interactions and drug screening in co-culture models. Sci Rep 2017; 7:11998. [PMID: 28931839 PMCID: PMC5607255 DOI: 10.1038/s41598-017-12049-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 08/31/2017] [Indexed: 12/12/2022] Open
Abstract
The tumour microenvironment is very complex, and essential in tumour development and drug resistance. The endothelium is critical in the tumour microenvironment: it provides nutrients and oxygen to the tumour and is essential for systemic drug delivery. Therefore, we report a simple, user-friendly microfluidic device for co-culture of a 3D breast tumour model and a 2D endothelium model for cross-talk and drug delivery studies. First, we demonstrated the endothelium was functional, whereas the tumour model exhibited in vivo features, e.g., oxygen gradients and preferential proliferation of cells with better access to nutrients and oxygen. Next, we observed the endothelium structure lost its integrity in the co-culture. Following this, we evaluated two drug formulations of TRAIL (TNF-related apoptosis inducing ligand): soluble and anchored to a LUV (large unilamellar vesicle). Both diffused through the endothelium, LUV-TRAIL being more efficient in killing tumour cells, showing no effect on the integrity of endothelium. Overall, we have developed a simple capillary force-based microfluidic device for 2D and 3D cell co-cultures. Our device allows high-throughput approaches, patterning different cell types and generating gradients without specialised equipment. We anticipate this microfluidic device will facilitate drug screening in a relevant microenvironment thanks to its simple, effective and user-friendly operation.
Collapse
|
28
|
Le Gac S, Nordhoff V. Microfluidics for mammalian embryo culture and selection: where do we stand now? Mol Hum Reprod 2016; 23:213-226. [DOI: 10.1093/molehr/gaw061] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Accepted: 09/02/2016] [Indexed: 12/26/2022] Open
|
29
|
Priwitaningrum DL, Blondé JBG, Sridhar A, van Baarlen J, Hennink WE, Storm G, Le Gac S, Prakash J. Tumor stroma-containing 3D spheroid arrays: A tool to study nanoparticle penetration. J Control Release 2016; 244:257-268. [PMID: 27616660 DOI: 10.1016/j.jconrel.2016.09.004] [Citation(s) in RCA: 101] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 09/05/2016] [Accepted: 09/07/2016] [Indexed: 12/14/2022]
Abstract
Nanoparticle penetration through tumor tissue after extravasation is considered as a key issue for tumor distribution and therapeutic effects. Most tumors possess abundant stroma, a fibrotic tissue composed of cancer-associated fibroblasts (CAFs) and extracellular matrix (ECM), which acts as a barrier for nanoparticle penetration. There is however a lack of suitable in vitro systems to study the tumor stroma penetration of nanoparticles. In the present study, we developed and thoroughly characterized a 3D co-culture spheroidal array to mimic tumor stroma and investigated the penetration of silica and PLGA nanoparticles in these spheroids. First, we examined human breast tumor patient biopsies to characterize the content and organization of stroma and found a high expression of alpha-smooth muscle actin (α-SMA; 40% positive area) and collagen-1 (50% positive area). Next, we prepared homospheroids of 4T1 mouse breast cancer cells or 3T3 mouse fibroblasts alone as well as heterospheroids combining 3T3 and 4T1 cells in different ratios (1:1 and 5:1) using a microwell array platform. Confocal live imaging revealed that fibroblasts distributed and reorganized within 48h in heterospheroids. Furthermore, immunohistochemical staining and gene expression analysis showed a proportional increase of α-SMA and collagen in heterospheroids with higher fibroblast ratios attaining 35% and 45% positive area at 5:1 (3T3:4T1) ratio, in a good match with the clinical breast tumor stroma. Subsequently, we studied the penetration of high and low negatively charged fluorescent silica nanoparticles (30nm; red and 100 or 70nm; green; zeta potential: -40mV and -20mV) and as well as Cy5-conjugated pegylated PLGA nanoparticles (200nm, -7mV) in both homo- and heterospheroid models. Fluorescent microscopy on spheroid cryosections after incubation with silica nanoparticles showed that 4T1 homospheroids allowed a high penetration of about 75-80% within 24h, with higher penetration in case of the 30nm nanoparticles. In contrast, spheroids with increasing fibroblast amounts significantly inhibited NP penetration. Silica nanoparticles with a less negative zeta potential exhibited lesser penetration compared to highly negative charged nanoparticles. Subsequently, similar experiments were conducted using Cy5-conjugated pegylated PLGA nanoparticles and confocal laser scanning microscopy; an increased nanoparticle penetration was found in 4T1 homospheroids until 48h, but significantly lower penetration in heterospheroids. Furthermore, we also developed human homospheroids (MDA-MB-231 or Panc-1 tumor cells) and heterospheroids (MDA-MB-231/BJ-hTert and Panc-1/pancreatic stellate cells) and performed silica nanoparticle (30 and 100nm) penetration studies. As a result, heterospheroids had significantly a lesser penetration of the nanoparticles compared to homospheroids. In conclusion, our data demonstrate that tumor stroma acts as a strong barrier for nanoparticle penetration. The 30-nm nanoparticles with low zeta potential favor deeper penetration. Furthermore, the herein proposed 3D co-culture platform that mimics the tumor stroma, is ideally suited to systematically investigate the factors influencing the penetration characteristics of newly developed nanomedicines to allow the design of nanoparticles with optimal penetration characteristics.
Collapse
|
30
|
Picollet-D’hahan N, Dolega ME, Liguori L, Marquette C, Le Gac S, Gidrol X, Martin DK. A 3D Toolbox to Enhance Physiological Relevance of Human Tissue Models. Trends Biotechnol 2016; 34:757-769. [DOI: 10.1016/j.tibtech.2016.06.012] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 06/17/2016] [Accepted: 06/28/2016] [Indexed: 01/21/2023]
|
31
|
Sinha R, Le Gac S, Verdonschot N, van den Berg A, Koopman B, Rouwkema J. Endothelial cell alignment as a result of anisotropic strain and flow induced shear stress combinations. Sci Rep 2016; 6:29510. [PMID: 27404382 PMCID: PMC4941569 DOI: 10.1038/srep29510] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Accepted: 06/20/2016] [Indexed: 12/23/2022] Open
Abstract
Endothelial cells (ECs) are continuously exposed in vivo to cyclic strain and shear stress from pulsatile blood flow. When these stimuli are applied in vitro, ECs adopt an appearance resembling their in vivo state, most apparent in their alignment (perpendicular to uniaxial strain and along the flow). Uniaxial strain and flow perpendicular to the strain, used in most in vitro studies, only represent the in vivo conditions in straight parts of vessels. The conditions present over large fractions of the vasculature can be better represented by anisotropic biaxial strains at various orientations to flow. To emulate these biological complexities in vitro, we have developed a medium-throughput device to screen for the effects on cells of variously oriented anisotropic biaxial strains and flow combinations. Upon the application of only strains for 24 h, ECs (HUVECs) aligned perpendicular to the maximum principal strain and the alignment was stronger for a higher maximum:minimum principal strain ratio. A 0.55 Pa shear stress, when applied alone or with strain for 24 h, caused cells to align along the flow. Studying EC response to such combined physiological mechanical stimuli was not possible with existing platforms and to our best knowledge, has not been reported before.
Collapse
|
32
|
Dembahri Z, Le Gac S, Tobal K, Chirani N, Rolando C, Benmouna F, Benmouna M. Polymer phase transition in n-lauryl methacrylate monoliths. POLYM INT 2016. [DOI: 10.1002/pi.5123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
33
|
Lajoinie G, De Cock I, Coussios CC, Lentacker I, Le Gac S, Stride E, Versluis M. In vitro methods to study bubble-cell interactions: Fundamentals and therapeutic applications. BIOMICROFLUIDICS 2016; 10:011501. [PMID: 26865903 PMCID: PMC4733084 DOI: 10.1063/1.4940429] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 01/05/2016] [Indexed: 05/08/2023]
Abstract
Besides their use as contrast agents for ultrasound imaging, microbubbles are increasingly studied for a wide range of therapeutic applications. In particular, their ability to enhance the uptake of drugs through the permeabilization of tissues and cell membranes shows great promise. In order to fully understand the numerous paths by which bubbles can interact with cells and the even larger number of possible biological responses from the cells, thorough and extensive work is necessary. In this review, we consider the range of experimental techniques implemented in in vitro studies with the aim of elucidating these microbubble-cell interactions. First of all, the variety of cell types and cell models available are discussed, emphasizing the need for more and more complex models replicating in vivo conditions together with experimental challenges associated with this increased complexity. Second, the different types of stabilized microbubbles and more recently developed droplets and particles are presented, followed by their acoustic or optical excitation methods. Finally, the techniques exploited to study the microbubble-cell interactions are reviewed. These techniques operate over a wide range of timescales, or even off-line, revealing particular aspects or subsequent effects of these interactions. Therefore, knowledge obtained from several techniques must be combined to elucidate the underlying processes.
Collapse
|
34
|
Aβhoff SJ, Sukas S, Yamaguchi T, Hommersom CA, Le Gac S, Katsonis N. Superstructures of chiral nematic microspheres as all-optical switchable distributors of light. Sci Rep 2015; 5:14183. [PMID: 26400584 PMCID: PMC4585848 DOI: 10.1038/srep14183] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 08/20/2015] [Indexed: 11/09/2022] Open
Abstract
Light technology is based on generating, detecting and controlling the wavelength, polarization and direction of light. Emerging applications range from electronics and telecommunication to health, defence and security. In particular, data transmission and communication technologies are currently asking for increasingly complex and fast devices, and therefore there is a growing interest in materials that can be used to transmit light and also to control the distribution of light in space and time. Here, we design chiral nematic microspheres whose shape enables them to reflect light of different wavelengths and handedness in all directions. Assembled in organized hexagonal superstructures, these microspheres of well-defined sizes communicate optically with high selectivity for the colour and chirality of light. Importantly, when the microspheres are doped with photo-responsive molecular switches, their chiroptical communication can be tuned, both gradually in wavelength and reversibly in polarization. Since the kinetics of the "on" and "off" switching can be adjusted by molecular engineering of the dopants and because the photonic cross-communication is selective with respect to the chirality of the incoming light, these photo-responsive microspheres show potential for chiroptical all-optical distributors and switches, in which wavelength, chirality and direction of the reflected light can be controlled independently and reversibly.
Collapse
|
35
|
Braakhuis HM, Kloet SK, Kezic S, Kuper F, Park MVDZ, Bellmann S, van der Zande M, Le Gac S, Krystek P, Peters RJB, Rietjens IMCM, Bouwmeester H. Progress and future of in vitro models to study translocation of nanoparticles. Arch Toxicol 2015; 89:1469-95. [PMID: 25975987 PMCID: PMC4551544 DOI: 10.1007/s00204-015-1518-5] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Accepted: 04/01/2015] [Indexed: 10/28/2022]
Abstract
The increasing use of nanoparticles in products likely results in increased exposure of both workers and consumers. Because of their small size, there are concerns that nanoparticles unintentionally cross the barriers of the human body. Several in vivo rodent studies show that, dependent on the exposure route, time, and concentration, and their characteristics, nanoparticles can cross the lung, gut, skin, and placental barrier. This review aims to evaluate the performance of in vitro models that mimic the barriers of the human body, with a focus on the lung, gut, skin, and placental barrier. For these barriers, in vitro models of varying complexity are available, ranging from single-cell-type monolayer to multi-cell (3D) models. Only a few studies are available that allow comparison of the in vitro translocation to in vivo data. This situation could change since the availability of analytical detection techniques is no longer a limiting factor for this comparison. We conclude that to further develop in vitro models to be used in risk assessment, the current strategy to improve the models to more closely mimic the human situation by using co-cultures of different cell types and microfluidic approaches to better control the tissue microenvironments are essential. At the current state of the art, the in vitro models do not yet allow prediction of absolute transfer rates but they do support the definition of relative transfer rates and can thus help to reduce animal testing by setting priorities for subsequent in vivo testing.
Collapse
|
36
|
Yang Y, Rho HS, Swennenhuis JF, Stevens M, Tibbe AGJ, Le Gac S, Gardeniers H, Terstappen LWMM. Abstract 367: Microfluidic devices for the interrogation of single circulating tumor cells. Cancer Res 2015. [DOI: 10.1158/1538-7445.am2015-367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Introduction: Genetic and phenotypic characterization of Circulating Tumor Cells (CTC) offer the opportunity for a “real time liquid biopsy”. However, heterogeneity and rarity of CTC command the need for individual cell characterization. Following an enrichment procedure of CTC from blood, the identification, isolation and manipulation of single CTC for further analysis without cell loss remains challenging. Here, we present microfluidic devices for parallel single cell whole genome amplification (psc WGA) and parallel probing of drug response of single cancer cells (psc probing).
Method: Microfluidic devices were designed using AUTOCAD software, and fabricated using PDMS multilayer soft-lithography. Cells from the SKBR-3 and MCF-7 breast cancer cell lines were used in the devices and identified using fluorescence microscopy after immunofluorescence staining. For pscWGA, the GE Single Cell GenomiPhi DNA Amplification kit was used under isothermal conditions.
Results: In the 1st scWGA device, single cancer cells were addressed in 16 individual reaction chambers, subsequently lyzed, and their DNA amplified on a chip. We successfully amplified DNA of single cancer cells in a ca. 23 nanoliter reaction volume. 1,000-fold amplified DNAs were validated using qPCR targeting a set of genes on different chromosomes. For WGA of CTC present in a large number of other cells, we developed a 2nd scWGA platform by combining a self-sorting microwell cell sorter and a microfluidic device. After filtration of a cell suspension using a microwell plate, cancer cells were identified using fluorescence microscopy at the bottom of the plate. Cells of interest were subsequently punched into the open-well structures of the microfluidic device for further analysis. The lysis and WGA reaction buffers were loaded using peristaltic pumping of integrated micro-valves. After cell lysis, DNA was amplified in the open-well reaction chamber. For validation ∼ 100 ng of DNA was pipetted out of the well. We also developed microfluidic devices to study drug-dose response of single cancer cells. This device is capable of capturing single cells, dosing various concentrations of drugs and exposing the cells to the drugs. We optimized the capturing efficiency using different sizes of beads (3 μm, 6 μm, and 15 μm) as well as MCF-7 cells. We demonstrated that single cancer cells could be exposed to different drug candidates in the reagent chambers and their response measured.
Conclusion: We successfully developed various microfluidic devices for individual cell characterization to be applied for CTC analysis. For genetic make-up, whole genome amplification of single cells either in suspension or in a self-sorting microwell plate was demonstrated. On-chip cell lysis and DNA amplification were performed and validated by qPCR targeting specific genes. In addition microfluidic devices were designed and tested to investigate single cell response to cancer drugs.
Citation Format: Yoonsun Yang, Hoon Suk Rho, Joost F. Swennenhuis, Michiel Stevens, Arjan GJ Tibbe, Séverine Le Gac, Han Gardeniers, Leon WMM Terstappen. Microfluidic devices for the interrogation of single circulating tumor cells. [abstract]. In: Proceedings of the 106th Annual Meeting of the American Association for Cancer Research; 2015 Apr 18-22; Philadelphia, PA. Philadelphia (PA): AACR; Cancer Res 2015;75(15 Suppl):Abstract nr 367. doi:10.1158/1538-7445.AM2015-367
Collapse
|
37
|
Kieslinger DC, Hao Z, Vergouw CG, Kostelijk EH, Lambalk CB, Le Gac S. In vitro development of donated frozen-thawed human embryos in a prototype static microfluidic device: a randomized controlled trial. Fertil Steril 2015; 103:680-6.e2. [DOI: 10.1016/j.fertnstert.2014.12.089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 11/25/2014] [Accepted: 12/03/2014] [Indexed: 12/27/2022]
|
38
|
Bomer JG, Prokofyev AV, van den Berg A, Le Gac S. Wafer-scale fabrication of glass-FEP-glass microfluidic devices for lipid bilayer experiments. LAB ON A CHIP 2014; 14:4461-4464. [PMID: 25284632 DOI: 10.1039/c4lc00921e] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We report a wafer-scale fabrication process for the production of glass-FEP-glass microdevices using UV-curable adhesive (NOA81) as gluing material, which is applied using a novel "spin & roll" approach. Devices are characterized for the uniformity of the gluing layer, presence of glue in the microchannels, and alignment precision. Experiments on lipid bilayers with electrophysiological recordings using a model pore-forming polypeptide are demonstrated.
Collapse
|
39
|
Harink B, Le Gac S, Barata D, van Blitterswijk C, Habibovic P. Microfluidic platform with four orthogonal and overlapping gradients for soluble compound screening in regenerative medicine research. Electrophoresis 2014; 36:475-84. [DOI: 10.1002/elps.201400286] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 09/19/2014] [Accepted: 09/24/2014] [Indexed: 11/10/2022]
|
40
|
Harink B, Le Gac S, Barata D, van Blitterswijk C, Habibovic P. Microtiter plate-sized standalone chip holder for microenvironmental physiological control in gas-impermeable microfluidic devices. LAB ON A CHIP 2014; 14:1816-1820. [PMID: 24752761 DOI: 10.1039/c4lc00190g] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We present a microtiter plate-sized standalone chip holder for precise control of physiological conditions inside closed microfluidic cell culture systems, made from gas-impermeable materials. Specifically, we demonstrate the suitability of the holder to support cell growth in a glass chip, to allow time-lapse imaging of live cells and the creation of a hypoxic environment, all relevant for applications in regenerative medicine research.
Collapse
|
41
|
Sukas S, Schreuder E, de Wagenaar B, Swennenhuis J, van den Berg A, Terstappen L, Le Gac S. A novel side electrode configuration integrated in fused silica microsystems for synchronous optical and electrical spectroscopy. LAB ON A CHIP 2014; 14:1821-1825. [PMID: 24756127 DOI: 10.1039/c3lc51433a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We present a novel electrode configuration consisting of coplanar side electrode pairs integrated at the half height of the microchannels for the creation of a homogeneous electric field distribution as well as for synchronous optical and electrical measurements. For the integration of such electrodes in fused silica microsystems, a dedicated microfabrication method was utilized, whereby an intermediate bonding layer was applied to lower the temperature for fusion bonding to avoid thereby metal degradation and subsequently to preserve the electrode structures. Finally, we demonstrate the applicability of our devices with integrated electrodes for single cell electrical lysis and simultaneous fluorescence and impedance measurements for both cell counting and characterization.
Collapse
|
42
|
Prokofyev A, Stimberg V, Bomer J, de Boer H, van A, Berg D, Le Gac S. Multiplexed Microfluidic Device for Parallel Electrophysiological Measurements on Independent Planar Lipid Bilayers. Biophys J 2014. [DOI: 10.1016/j.bpj.2013.11.3496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
43
|
Stimberg VC, Bomer Hans JG, de Boer L, van den Berg A, Le Gac S. Probing Simultaneously Membrane Dynamics and Protein Activity in Suspended Bilayers in a Microfluidic Format. Biophys J 2014. [DOI: 10.1016/j.bpj.2013.11.536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
44
|
Hemkemeyer SA, Schwarzer C, Boiani M, Ehmcke J, Le Gac S, Schlatt S, Nordhoff V. Effects of embryo culture media do not persist after implantation: a histological study in mice. Hum Reprod 2013; 29:220-33. [PMID: 24324026 DOI: 10.1093/humrep/det411] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
STUDY QUESTION Is post-implantation embryonic development after blastocyst transfer affected by exposure to different assisted reproduction technology (ART) culture media? SUMMARY ANSWER Fetal development and placental histology of ART embryos cultured in vitro in different ART media was not impaired compared with embryos grown in vivo. WHAT IS KNOWN ALREADY The application of different in vitro culture (IVC) media for human ART has an effect on birthweight of newborns. In the mouse model, differences in blastocyst formation were reported after culture in different ART media. Moreover, abnormalities in the liver and heart have been detected as a result of suboptimal IVC conditions. STUDY DESIGN, SIZE, DURATION Fertilized oocytes from inbred and outbred breeding schemes were retrieved and either immediately transferred to foster mothers or incubated in control or human ART culture media up to the blastocyst stage prior to transfer. Placental and fetal anatomy and particularly bone development were evaluated. PARTICIPANTS/MATERIALS, SETTING, METHODS B6C3F1 female mice were used as oocyte donors after ovulation induction. C57Bl/6 and CD1 males were used for mating and CD1 females as foster mothers for embryo transfer. Fertilized oocytes were recovered from mated females and incubated in sequential human ART media (ISM1/ISM2 and HTF/Multiblast), in control media [KSOM(aa) and Whitten's medium] or grown in utero without IVC (zygote control). As in vivo, control B6C3F1 females were superovulated and left untreated. Fetuses and placentae were isolated by Caesarean section and analysed at 18.5 days post-coitum (dpc) for placenta composition and at 15.5 dpc for body weight, crown-rump length (CRL), fetal organ development, morphological development, total bone length and extent of bone ossification. MAIN RESULTS AND THE ROLE OF CHANCE No major differences in the number of implantation sites or in histological appearance of the placentae were detected. CRL of KSOM(aa) fetuses was higher compared with zygote control and Whitten's medium. Histological analysis of tissue sections revealed no gross morphological differences compared with the in vitro groups or in vivo controls. Furthermore, no changes in skeletal development and degree of ossification were observed. However, fibula and tibia of ISM1/ISM2 fetuses were longer than the respective ones from in vivo fetuses. LIMITATIONS, REASONS FOR CAUTION Findings in the mouse embryo and fetus may not be fully transferable to humans. In addition to skeletal development and placentation, there may be other parameters, e.g. on the molecular level which respond to IVC in ART media. Some comparisons have limited statistical power. WIDER IMPLICATIONS OF THE FINDINGS Our data suggest that once implantation is achieved, subsequent post-implantation development unfolds normally, resulting in healthy fetuses. With mouse models, we gather information for the safety of human ART culture media. Our mouse study is reassuring for the safety of ART conditions on human embryonic development, given the lack of bold detrimental effects observed in the mouse model. STUDY FUNDING/COMPETING INTEREST(S) This work was supported by the Deutsche Forschungsgemeinschaft (BO 2540/4-1 and SCHL 394/9-1) and by the Nederlandse Organisatie voor Wetenschappelijk Onderzoek (S.L.G.); Bilateral grant NWO-DFG 63-258. None of the authors has any conflict of interest to declare. TRIAL REGISTRATION NUMBER Not applicable.
Collapse
|
45
|
Harink B, Le Gac S, Truckenmüller R, van Blitterswijk C, Habibovic P. Regeneration-on-a-chip? The perspectives on use of microfluidics in regenerative medicine. LAB ON A CHIP 2013; 13:3512-28. [PMID: 23877890 DOI: 10.1039/c3lc50293g] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
The aim of regenerative medicine is to restore or establish normal function of damaged tissues or organs. Tremendous efforts are placed into development of novel regenerative strategies, involving (stem) cells, soluble factors, biomaterials or combinations thereof, as a result of the growing need caused by continuous population aging. To satisfy this need, fast and reliable assessment of (biological) performance is sought, not only to select the potentially interesting candidates, but also to rule out poor ones at an early stage of development. Microfluidics may provide a new avenue to accelerate research and development in the field of regenerative medicine as it has proven its maturity for the realization of high-throughput screening platforms. In addition, microfluidic systems offer other advantages such as the possibility to create in vivo-like microenvironments. Besides the complexity of organs or tissues that need to be regenerated, regenerative medicine brings additional challenges of complex regeneration processes and strategies. The question therefore arises whether so much complexity can be integrated into microfluidic systems without compromising reliability and throughput of assays. With this review, we aim to investigate whether microfluidics can become widely applied in regenerative medicine research and/or strategies.
Collapse
|
46
|
Stimberg VC, Bomer JG, van Uitert I, van den Berg A, Le Gac S. High yield, reproducible and quasi-automated bilayer formation in a microfluidic format. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2013; 9:1076-1085. [PMID: 23139010 DOI: 10.1002/smll.201201821] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Revised: 08/27/2012] [Indexed: 05/28/2023]
Abstract
A microfluidic platform is reported for various experimentation schemes on cell membrane models and membrane proteins using a combination of electrical and optical measurements, including confocal microscopy. Bilayer lipid membranes (BLMs) are prepared in the device upon spontaneous and instantaneous thinning of the lipid solution in a 100-μm dry-etched aperture in a 12.5-μm thick Teflon foil. Using this quasi-automated approach, a remarkable 100% membrane formation yield is reached (including reflushing in 4% of the cases), and BLMs are stable for up to 36 h. Furthermore, the potential of this platform is demonstrated for (i) the in-depth characterization of BLMs comprising both synthetic and natural lipids (1,2-diphytanoyl-sn-glycero-3-phosphocholine (DPhPC) and L-α-phosphatidylcholine (L-α-PC)/cholesterol, respectively) in terms of seal resistance, capacitance, surface area, specific capacitance, and membrane hydrophobic thickness; (ii) confocal microscopy imaging of phase separation in sphingomyelin/L-α-PC/cholesterol ternary membranes; (iii) electrical measurements of individual nanopores (α-hemolysin, gramicidin); and (iv) indirect assessment of the alteration of membrane properties upon exposure to chemical stimuli using the natural nanopore gramicidin as a sensor.
Collapse
|
47
|
Naito T, Arayanarakool R, Le Gac S, Yasui T, Kaji N, Tokeshi M, van den Berg A, Baba Y. Temperature-driven self-actuated microchamber sealing system for highly integrated microfluidic devices. LAB ON A CHIP 2013; 13:452-458. [PMID: 23235490 DOI: 10.1039/c2lc41030c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We present here a novel microchamber sealing valve that is self-actuated by a pressure change during the temperature change in the thermal activation of reactions. Actuation of our valve requires only the use of the same heating device as employed for the reactions. A thermoplastic UV-curable polymer is used as a device material; the polymer allows realization of the temperature-driven valve actuation as well as the fabrication of multi-layered devices. The self-actuated valve achieves effective sealing of the microchamber for the polymerase chain reaction (PCR) even at 90 °C, which is essential for developing highly parallel PCR array devices without the need for complicated peripherals to control the valve operation.
Collapse
|
48
|
Esteves TC, van Rossem F, Nordhoff V, Schlatt S, Boiani M, Le Gac S. A microfluidic system supports single mouse embryo culture leading to full-term development. RSC Adv 2013. [DOI: 10.1039/c3ra44453h] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
|
49
|
Abstract
Electroporation is a powerful technique to increase the permeability of cell membranes and subsequently introduce foreign materials into cells. Pores are created in the cell membrane upon application of an electric field (kV/cm). Most applications employ bulk electroporation, at the scale of 1 mL of cells (ca. one million cells). However, recent progresses have shown the interest to miniaturize the technique to a single cell. Single cell electroporation is achieved either using microelectrodes which are placed in close vicinity to one cell, or in a microfluidic format. We focus here on this second approach, where individual cells are trapped in micrometer-size structures within a microchip, exposed in situ to a high electric field and loaded with either a dye (proof-of-principle experiments) or a plasmid. Specifically, we present one device that includes an array of independent electroporation sites for customized and successive poration of nine cells. The different steps of the single cell electroporation protocol are detailed including cell sample preparation, cell trapping, actual cell poration and on-chip detection of pore formation. Electroporation is illustrated here with the transport of dyes through the plasma membrane, the transfection of cells with GFP-encoding plasmids, and the study of the ERK1 signaling pathway using a GFP-ERK1 protein construct expressed by the cells after their transfection with the corresponding plasmid. This last example highlights the power of microfluidics with the implementation of various steps of a process (cell poration, culture, imaging) performed at the single cell level, on a single device.
Collapse
|
50
|
Stimberg V, van den Berg A, Le Gac S. Multiplexed Microfluidic Device for Bilayer Experimentation and Drug Screening Assays on Membrane Proteins. Biophys J 2012. [DOI: 10.1016/j.bpj.2011.11.182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|