26
|
Isoyama T, Abe Y, Chinzei T, Mochizuki S, Karita T, Saito I, Ono T, Kouno A, Baba K, Imachi K. Using one rotary blood pump to produce separate pulsatile circulations in the upper and lower halves of the body. Artif Organs 2000; 24:680-2. [PMID: 10971262 DOI: 10.1046/j.1525-1594.2000.06592.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Separate systemic circulations with pulsatile flow were obtained using 1 rotary blood pump as a left ventricular assist device. The outlet of the pump was divided into 2 conduits, 1 connected to the upper half of the body and the other connected to the lower half. An electric actuator that clamped the 2 outlet conduits alternately provided pulsatile flows. An in vitro experiment showed that the pulsatility phases of the upper and lower halves of the body were complementary with pulsatile flow, and an in vivo experiment showed that controlled flow distributions of continuous flows could be obtained.
Collapse
|
27
|
Abe Y, Ono T, Isoyama T, Mochizuki S, Iwasaki K, Chinzei T, Saito I, Kouno A, Imachi K. Development of a miniature undulation pump for the distributed artificial heart. Artif Organs 2000; 24:656-8. [PMID: 10971257 DOI: 10.1046/j.1525-1594.2000.06578.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Research of the distributed artificial heart is important not only to acquire the means of individual organ perfusion but also to clarify the characteristics of the organ and the mechanism of blood distribution. To investigate the distributed artificial heart, the miniature undulation pump was developed. The outer diameter and the thickness of the developed pump were 38 mm and 11 mm, respectively. The priming volume of the pump was 3.2 ml. The total size including the motor unit was 38 mm in diameter and 32 mm in length. The total weight was 67.5 g. The total volume was 27.5 ml. The pump was driven with pulse width modulation by using a 1 chip motor controller. More than 5 L/min of continuous output could be obtained. The results showed that the developed miniature undulation pump system had enough performance for individual organ perfusion.
Collapse
|
28
|
Mochizuki S, Abe Y, Chinzei T, Isoyama T, Ono T, Saito I, Guba P, Karita T, Sun YP, Kouno A, Suzuki T, Baba K, Mabuchi K, Imachi K. Results of animal experiments using an undulation pump total artificial heart: analysis of 10 day and 19 day survival. ASAIO J 2000; 46:500-4. [PMID: 10926154 DOI: 10.1097/00002480-200007000-00026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
An undulation pump is a special rotary blood pump in which rotation of a brushless DC motor is transformed to an undulating motion by a disc in the pump housing attached by means of a special link mechanism. In the blood pump, a closed line between the disc and housing moves from the inlet to the outlet by this undulating disc motion, which sucks and pushes the blood from the inlet to the outlet. Because the same phenomena occurs at both sides of the disc, a continuous flow is obtained when the motor rotational speed is constant. The pump flow pattern can be easily changed from continuous flow to pulsatile flow by controlling the motor drive current pattern. A seal membrane made of segmented polyurethane protects the blood from invading the link mechanism as well as the motor. UPTAH is fabricated with two undulation pumps and two brushless DC motors. Its size is 75 mm in diameter and 80 mm long, and it has one of the great advantage of no compliance chamber required in the system. UPTAHs were implanted under cardiopulmonary bypass (CPB) into the chest cavities of 16 goats, each weighing between 41 and 72 kg. No anticoagulant and antiplatelet agent was used after the surgery. The left atrial pressure was automatically controlled to prevent its elevation and sucking of the atrial wall into the atrial cuff. The following results were obtained: (1) UPTAHs fit well into all the goats; (2) the longest survival was 19.8 days, the cause of death was bleeding from the aortic anastomosis; (3) No thrombus was observed in the blood pump despite no anticoagulant use. Hemolysis depended upon the length of CPB during surgery. When CPB time was within 2 hours, hemolysis level returned to baseline within a few days of the surgery. UPTAH is a promising implantable TAH, because of its small size and easy controllability.
Collapse
|
29
|
Abe Y, Chinzei T, Isoyama T, Mochizuki S, Saito I, Karita T, Ono T, Kouno A, Baba K, Imachi K. Analysis of hemodynamic response with 1/R control on biventricular bypass goat. Artif Organs 2000; 24:312-5. [PMID: 10816207 DOI: 10.1046/j.1525-1594.2000.06534-3.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A conductance and arterial pressure based method (1/R control) to determine the cardiac output (CO) of a total artificial heart (TAH) was developed to provide a central nervous system with control over the output of TAH. In order to clarify the deference in hemodynamic response between natural heart and 1/R control, biventricular bypass was introduced in the goat. After 2 pneumatically driven sac-type blood pumps were connected to the natural heart, the pulmonary artery was totally clamped to acquire 100% right heart bypass, and the ascending aorta was stenosed to acquire about 60 to 90% left heart bypass; 1/R control was performed substituting the output of the right artificial heart for the CO. The results demonstrated that stable control could be achieved. A discrepancy was often seen between the pulse rate (PR) of the artificial heart and the heart rate (HR) in absolute value. However, the relative changes of PR were quite similar to that of HR for the most part, indicating that the responses of 1/R control were the duplication of natural cardiac responses in normal daily activity.
Collapse
|
30
|
Noji M, Bandoh T, Isoyama T, Nagaoka S, Fujiwara M, Takemura T. [A case of complete regression of liver metastases by treatment with Futraful supposition]. Gan To Kagaku Ryoho 2000; 27:285-8. [PMID: 10700902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
The patient was a 57-year-old man abnormalities indicated in examinations by X-ray and ultrasonography in February, 1991. X-ray and endoscopic examination revealed a Borrmann type 3 carcinoma in the posterior wall and lesser curvature of the upper body of the stomach. The liver was swollen to 3 fingerbreadths on the right mid-clavicular line. Multiple liver metastases were revealed by computed tomography (CT). Proximal gastrectomy was done. From March 24, 1991, a Futraful suppository (1,500 mg/day) was given daily. After 4 months, CT showed the reduction and partial disappearance of the low-density areas of the liver. After 2 years and 7 months, CT showed very small low-density areas, which completely disappeared by April, 1998. The patient has had a good quality of life. According to the General Rules for Gastric Cancer Study, the patient belongs to the class of complete response.
Collapse
|
31
|
Yamamoto Y, Sofikitis N, Ono K, Kaki T, Isoyama T, Suzuki N, Miyagawa I. Postmeiotic modifications of spermatogenic cells are accompanied by inhibition of telomerase activity. UROLOGICAL RESEARCH 1999; 27:336-45. [PMID: 10550521 DOI: 10.1007/s002400050160] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
We investigated whether testicular telomerase activity is due to telomerase expression in all cells or expression in a limited number of cells. Telomerase activity was assayed in highly purified fractions of spermatogonia cells plus primary spermatocytes, secondary spermatocytes plus round spermatids, secondary spermatocytes plus spermatids plus spermatozoa, round spermatids, or spermatozoa prepared from healthy or cryptorchid animals. Telomerase activity was additionally assayed in testicular tissue of prepubertal animals and animals with Sertoli cell only pathophysiology. Telomerase activity was detected in fractions containing primary spermatocytes and/or secondary spermatocytes and/or spermatids. Fractions enriched in round spermatids were positive for telomerase activity. In contrast, spermatozoa or Sertoli cell fractions were negative for telomerase activity. Using the relative telomerase activity assay and the sensitive quantitative telomerase assay to quantify telomerase activity, we showed that induction of cryptorchidism does not result in quantitative alterations in testicular tissue telomerase activity. In addition, elimination of round spermatids does not lead to significant alterations in testicular tissue telomerase activity. The present results suggest that the male gamete telomerase activity is inhibited during spermiogenesis. Furthermore, it appears that spermatogonia/primary spermatocytes are the main sources of telomerase activity in the testis.
Collapse
|
32
|
Abe Y, Chinzei T, Ono T, Mochizuki S, Saito I, Guba P, Karita T, Sun YP, Kouno A, Isoyama T, Baba K, Imachi K. Implantation of the undulation pump total artificial heart in the goat. Artif Organs 1999; 23:932-8. [PMID: 10564292 DOI: 10.1046/j.1525-1594.1999.06033.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The undulation pump total artificial heart (UPTAH) was developed by using small-size continuous-flow displacement-type blood pumps (undulation pump). To clarify and improve the problems accompanied by the implantation in the chest, 14 animal experiments were performed on goats weighing 41.3-79.2 kg. The UPTAH could be implanted in the chest of all goats and was driven with a modulation pulsatile mode. The first problem was the atrial suction effect. This problem could be prevented to some extent by developing the soft disk and by improving atrial cuffs. An automatic detection and releasing of the atrial suction effect was also tried. The next problem was acute lung edema accompanied by the postural change of the animal. Development of the automatic control of left atrial pressure could prevent this problem. Small blood leakage from a pinpoint hole in the seal membrane was the next problem. Improvement of the manufacturing procedure of the membrane prevented this. With these improvements, a 10 day survival could be obtained with this unique implantable total artificial heart.
Collapse
|
33
|
Isoyama T, Kamoshita N, Yasui K, Iwai A, Shiroki K, Toyoda H, Yamada A, Takasaki Y, Nomoto A. Lower concentration of La protein required for internal ribosome entry on hepatitis C virus RNA than on poliovirus RNA. J Gen Virol 1999; 80 ( Pt 9):2319-2327. [PMID: 10501483 DOI: 10.1099/0022-1317-80-9-2319] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Translation initiation of poliovirus and hepatitis C virus (HCV) RNA occurs by entry of ribosomes to the internal RNA sequence, called the internal ribosomal entry site (IRES). Both IRES bind to the La protein and are thought to require the protein for their translation initiation activity, although they are greatly different in both the primary and predicted secondary structures. To compare the La protein requirement for these IRES, we took advantage of I-RNA from the yeast Saccharomyces cerevisiae, which has been reported to bind to La protein and block poliovirus IRES-mediated translation initiation. In a cell-free translation system prepared from HeLa cells, yeast I-RNA inhibited translation initiation on poliovirus RNA as expected, but did not significantly inhibit translation initiation on HCV RNA. However, the translation initiation directed by either IRES was apparently inhibited by I-RNA in rabbit reticulocyte lysates, in which La protein is limiting. I-RNA-mediated inhibition of HCV IRES-dependent translation in rabbit reticulocyte lysates was reversed by exogenous addition of purified recombinant La protein of smaller amounts than necessary to reverse poliovirus IRES-dependent translation. These results suggest that HCV IRES requires lower concentrations of La protein for its function than does poliovirus IRES. Immunofluorescence studies showed that HCV infection appeared not to affect the subcellular localization of La protein, which exists mainly in the nucleus, although La protein redistributed to the cytoplasm after poliovirus infection. The data are compatible with the low requirement of La protein for HCV IRES activity.
Collapse
|
34
|
Shiroki K, Isoyama T, Kuge S, Ishii T, Ohmi S, Hata S, Suzuki K, Takasaki Y, Nomoto A. Intracellular redistribution of truncated La protein produced by poliovirus 3Cpro-mediated cleavage. J Virol 1999; 73:2193-200. [PMID: 9971802 PMCID: PMC104464 DOI: 10.1128/jvi.73.3.2193-2200.1999] [Citation(s) in RCA: 88] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/1998] [Accepted: 11/16/1998] [Indexed: 02/05/2023] Open
Abstract
The La autoantigen (also known as SS-B), a cellular RNA binding protein, may shuttle between the nucleus and cytoplasm, but it is mainly located in the nucleus. La protein is redistributed to the cytoplasm after poliovirus infection. An in vitro translation study demonstrated that La protein stimulated the internal initiation of poliovirus translation. In the present study, a part of the La protein was shown to be cleaved in poliovirus-infected HeLa cells, and this cleavage appeared to be mediated by poliovirus-specific protease 3C (3Cpro). Truncated La protein (dl-La) was produced in vitro from recombinant La protein by cleavage with purified 3Cpro at only one Gln358-Gly359 peptide bond in the 408-amino-acid (aa) sequence of La protein. The dl-La expressed in L cells was detected in the cytoplasm. However, green fluorescence protein linked to the C-terminal 50-aa sequence of La protein was localized in the nucleus, suggesting that this C-terminal region contributes to the steady-state nuclear localization of the intact La protein in uninfected cells. The dl-La retained the enhancing activity of translation initiation driven by poliovirus RNA in rabbit reticulocyte lysates. These results suggest that La protein is cleaved by 3Cpro in the course of poliovirus infection and that the dl-La is redistributed to the cytoplasm. dl-La, as well as La protein, may play a role in stimulating the internal initiation of poliovirus translation in the cytoplasm.
Collapse
|
35
|
Abe Y, Chinzei T, Isoyama T, Ono T, Mochizuki S, Saito I, Guba P, Karita T, Sun YP, Kouno A, Suzuki T, Baba K, Mabuchi K, Imachi K. Present status of the total artificial heart at the University of Tokyo. Artif Organs 1999; 23:221-8. [PMID: 10198712 DOI: 10.1046/j.1525-1594.1999.06325.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
At the University of Tokyo, various types of total artificial heart (TAH) systems have been studied since 1959. At the present time, 2 types of implantable TAH have been developed. One is an undulation pump TAH (UPTAH) and the other is a flow transformed pulsatile TAH (FTPTAH). Using the UPTAH, 14 cases of implantation were performed in goats and 10 days' survival obtained. The new type of FTPTAH is under a prototype study. To prevent ring thrombus, a polyurethane membrane valve, a jellyfish valve, has been developed. The longest in vivo experiences with this valve in the TAH blood pump have been 312 days in the left side blood pump and 414 days in the right side blood pump. Conductance and arterial pressure based control (1/R control) can realize the physiological control of the TAH. Using 1/R control, 532 days of survival could be obtained in a goat with a paracorporeal TAH. The technique required to apply this control method to a implantable TAH is under development. We have proposed a new 5 year research project of the implantable TAH entitled "Comprehensive Basic Research on the Development of a Japanese Original Implantable Total Artificial Heart" to The Ministry of Welfare.
Collapse
|
36
|
Isoyama T, Shiroki K. [Translational control in eucaryote: recent progress]. TANPAKUSHITSU KAKUSAN KOSO. PROTEIN, NUCLEIC ACID, ENZYME 1999; 44:149-56. [PMID: 10047732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
37
|
Masuda R, Tanaka I, Furuhata Y, Inoue M, Isoyama T. [Spontaneous esophageal rupture after gastrointestinal examination using barium]. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 1998; 46:1182-5. [PMID: 9884574 DOI: 10.1007/bf03217898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We experienced a case of spontaneous rupture of the esophagus after gastrointestinal examination using barium. A 48-year-old male experienced severe chest pain after vomiting following gastrointestinal examination. Chest X-ray revealed a right pneumothorax and pleural effusion by barium. We diagnosed spontaneous rupture of the esophagus and performed right thoracotomy 6 hours after onset of symptoms. At 10 cm above the diaphragm, there was a vertical perforation 3 cm in length. Following saline lavage, the ruptured esophageal wall was directly closed by the layer to layer method. The post operative course was uneventful and the patient was discharged 3 weeks after surgery. Cases of spontaneous rupture of the esophagus into the right thoracic cavity induced by gastrointestinal examination are extremely rare.
Collapse
|
38
|
Abe Y, Chinzei T, Mabuchi K, Snyder AJ, Isoyama T, Imanishi K, Yonezawa T, Matsuura H, Kouno A, Ono T, Atsumi K, Fujimasa I, Imachi K. Physiological control of a total artificial heart: conductance- and arterial pressure-based control. J Appl Physiol (1985) 1998; 84:868-76. [PMID: 9480945 DOI: 10.1152/jappl.1998.84.3.868] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
To obtain a physiological response by a total artificial heart (TAH), while eliminating the hemodynamic abnormalities commonly observed with its use, we proposed the use of a conductance- and arterial pressure-based method (1/R control) to determine TAH cardiac output. In this study, we endeavored to make use of a variable more closely tied to central nervous system (CNS) efferents, systemic conductance, to provide the CNS with more direct control over the output of the TAH. The control equation that calculates the target cardiac output of the TAH was constructed on the basis of measurement of blood pressures and TAH flow. The 1/R control method was tested in TAH-recipient goats with an automatic method by using a microcomputer. In 1/R control animals, the typical TAH pathologies, such as mild arterial hypertension and substantial systemic venous hypertension, did not occur. Cardiac output varied according to daily activity level and exercise in a manner similar to that observed in natural heart goats. These results indicate that we have determined a control method for the TAH that avoids hemodynamic abnormalities exhibited by other TAH control systems and that exhibits physiological responses to exercise and daily activities under the conditions tested. The stability of the control and the complete lack of inappropriate excursions in cardiac output is suggestive of CNS involvement in stabilizing the system.
Collapse
|
39
|
Sofikitis N, Yamamoto Y, Isoyama T, Miyagawa I. The early haploid male gamete develops a capacity for fertilization after the coalescence of the proacrosomal granules. Hum Reprod 1997; 12:2713-9. [PMID: 9455841 DOI: 10.1093/humrep/12.12.2713] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
We compared the fertilizing capacity of rabbit testicular round spermatids (i) before appearance of the proacrosomal granules (stage -1), (ii) with two to three proacrosomal granules attached to the nucleus (stage -2) and (iii) with one granule attached to the nucleus (stages -3 to -5). Testicular samples were minced and observed via confocal scanning laser microscopy, which allows intracellular observation at high magnification and the subsequent identification of acrosomal granules and round spermatids. Nuclei of round spermatids of stage -1 (group A), -2 (group B), and -3 to -5 (group C) were isolated and injected into mature rabbit oocytes. At 24 and 72 h post-injection the number of cleaved oocytes and morulae/blastocysts, respectively, were significantly lower in groups A and B than group C. These results suggest that the rabbit round spermatid develops fertilizing potential after the stage at which the coalescence of the acrosomal granules occurs.
Collapse
|
40
|
Abe Y, Chinzei T, Isoyama T, Ono T, Mochizuki S, Mabuchi K, Baba K, Matsuura H, Sun YP, Kouno A, Atsumi K, Fujimasa I, Imachi K. Development of the undulation pump total artificial heart. Artif Organs 1997; 21:665-9. [PMID: 9212936 DOI: 10.1111/j.1525-1594.1997.tb03719.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The undulation pump is a small size continuous flow displacement type blood pump that has been developed for an artificial heart. Using undulation pumps, 2 types of implantable total artificial hearts (TAHs), the undulation pump TAH (UPTAH) type 1 (UPTAH 1) and UPTAH type 2 (UPTAH 2) were developed. Both UPTAHs were designed to be small enough to implant into the chest of a goat, the experimental animal. UPTAH 1 could be reduced in size to 75 mm in diameter and 78 mm in length. The weight was 520 g. UPTAH 2 could be reduced in size to 75 mm in diameter and 80 mm in length. The weight was 650 g. UPTAH 2 could be tested in an animal experiment using an adult female goat weighing 52.3 kg. The UPTAH 2 could be implanted successfully into the goat's chest with a good fit. The goat stood after the surgery and extubation and survived for 3 h and 40 min; thus, the potential of the UPTAH for a practical implantable TAH was demonstrated.
Collapse
|
41
|
Mabuchi K, Chinzei T, Abe Y, Imanishi K, Isoyama T, Matsuura H, Tago T, Kouno A, Ono T, Imachi K, Fujimasa I. Use of a Catecholamine Sensor in the Control of an Artificial Heart System. Int J Artif Organs 1997. [DOI: 10.1177/039139889702000108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
An electrochemical sensor system to allow real-time measurement and feedback of catecholamine concentrations was developed for use in the control of artificial hearts. Electrochemical analyses were carried out using a carbon fiber working electrode, an Ag-AgCI reference electrode, and a potentiostat. The operating parameters of the pneumatically-driven artificial heart system were altered in accordance with the algorithm for changes in the catecholamine concentration. The minimum detectable concentrations of both adrenaline and noradrenaline in a mock circulatory system using a phosphate-buffered solution were approximately 1-2 ng/ml (10-8 mol/L). An artificial heart control system utilizing this set-up performed satisfactorily without delay, although sensor sensitivity decreased when placed in goat plasma instead of a phosphate-buffered solution, due to the adsorption of various substances such as plasma proteins onto the electrodes. This study demonstrated the future feasibility of a feedback control system for artificial hearts using catecholamine concentrations.
Collapse
|
42
|
Mabuchi K, Chinzei T, Abe Y, Imanishi K, Isoyama T, Matsuura H, Tago T, Kouno A, Ono T, Imachi K, Fujimasa I. Use of a catecholamine sensor in the control of an artificial heart system. Int J Artif Organs 1997; 20:37-42. [PMID: 9062830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
An electrochemical sensor system to allow real-time measurement and feedback of catecholamine concentrations was developed for use in the control of artificial hearts. Electrochemical analyses were carried out using a carbon fiber working electrode, an Ag-AgCl reference electrode, and a potentiostat. The operating parameters of the pneumatically-driven artificial heart system were altered in accordance with the algorithm for changes in the catecholamine concentration. The minimum detectable concentrations of both adrenaline and noradrenaline in a mock circulatory system using a phosphate-buffered solution were approximately 1-2 ng/ml (10(-8) mol/L). An artificial heart control system utilizing this set-up performed satisfactorily without delay, although sensor sensitivity decreased when placed in goat plasma instead of a phosphate-buffered solution, due to the adsorption of various substances such as plasma proteins onto the electrodes. This study demonstrated the future feasibility of a feedback control system for artificial hearts using catecholamine concentrations.
Collapse
|
43
|
Nagaoka S, Toyoshima H, Bandoh T, Isoyama T, Kasahara D, Kusafuka K, Takemura T, Tanaka N. Composite carcinoid-adenocarcinoma tumor of the stomach: report of a case. Surg Today 1996; 26:184-8. [PMID: 8845611 DOI: 10.1007/bf00311504] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We describe herein the case of an extremely unusual composite carcinoid-adenocarcinoma tumor of the stomach, most of which was found to be carcinoid. The carcinoid tumor component exhibited argyrophilic granules, immunohistochemical localization of chromogranin, and serotonin immunoreaction. Conversely, none of the adenocarcinoma component reacted with argyrophilia, chromogranin, or serotonin. DNA flow cytometric analysis revealed a near-diploid pattern in the carcinoid element and an aneuploid pattern in the adenocarcinoma element. The transitional zone and continuity between the two tumor components were observed. These findings suggest that the tumor originated from the endocrine system, although part of it showed nonendocrine differentiation. The patient died approximately 6 months after the onset of symptoms and an autopsy could not be performed.
Collapse
|
44
|
Imanishi K, Imachi K, Yoshito H, Isoyama T, Abe Y, Chinzei T, Mabuchi K, Kanda K, Tsutsui N, Suma K, Fujimasa I. A percutaneously accessible pulsatile left ventricular assist device: modified assist device type 5. Artif Organs 1996; 20:147-51. [PMID: 8712960 DOI: 10.1111/j.1525-1594.1996.tb00718.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, respectively. During systole, the blood is sucked from the left ventricle through the inflow valve of the cannula connected to the blood pump, and during diastole, the blood is ejected to the root of the aorta through the outflow valve. In vitro and in vivo evaluations of the pump performance were performed. The maximum flow rate of 1.9 L/min was obtained in the mock circulatory system. In our animal experiment, effective systolic unloading and diastolic augmentation were observed by activation of this system during regular sinus rhythm. In conclusion, the MAD-5 is thought to be percutaneously accessible and increases systemic and coronary flow.
Collapse
|
45
|
Isoyama T, Imachi K, Abe Y, Chinzei T, Imanishi K, Mabuchi K, Matsuura H, Fujimasa I. New version of flow-transformed pulsatile total artificial heart with no electrical switching valve. Artif Organs 1995; 19:694-6. [PMID: 8572976 DOI: 10.1111/j.1525-1594.1995.tb02405.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The flow-transformed pulsatile total artificial heart (FTPTAH) is a new pulsatile total artificial heart that consists of a single continuous flow rotary blood pump and blood flow switching valves. It can perfuse the pulmonary and the systemic circulation alternately with pulsatile flow. A new version of the FTPTAH, which consists of one undulation pump (UP), 4 jellyfish valves, and a compensatory chamber, has been proposed. The UP is a reversible continuous flow blood pump, and flow transformation is caused by switching the direction of the motor rotation so that no electrical flow switching valve is needed. A prototype model could perfuse alternately pulmonary and systemic circulation with 3.0 L/min in a mock circulation. Unoxygenated blood in the UP at the end of pulmonary circulation will be stored in the compensatory chamber by shifting a flexible membrane to the direction of the left atrium (LA); therefore, the blood is not sent to the systemic circulation.
Collapse
|
46
|
Imachi K, Chinzei T, Abe Y, Isoyama T, Mabuchi K, Ono T, Kouno A, Imanishi K, Kusakabe M, Onuma M. Development of a new apparatus to observe microcirculation chronically in continuous flow blood pump research. Artif Organs 1995; 19:725-8. [PMID: 8572983 DOI: 10.1111/j.1525-1594.1995.tb02412.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
To observe microcirculation chronically is an important key to the successful evaluation of the continuous flow blood pump. In this study, we succeeded in developing a new apparatus by which microcirculation could be observed chronically without a microscope in a conscious animal. The apparatus utilizes a charge coupled device (CCD). A thin living tissue, such as mesentery, is put directly on a highly integrated CCD and is lit up through the tissue with a light-emitting diode (LED). The vascular nets in the tissue are projected onto the CCD like a contact photograph, which is then sent to a television screen and which can be used to analyze their motion and function. A 0.5-inch CCD having 250,000 pixels was used in this study. The cover glass of the CCD was removed, and a fiber optic plate was fixed onto the surface of the CCD for the tissue to be able to contact with the apparatus surface without clearance. The CCD as well as the LED were molded with epoxy resin for electrical insulation. The apparatus was 35 mm wide and 12 mm high with a micro stand for an LED, which can be easily implanted into an animal. The apparatus was implanted into a rabbit for 12 h. The configuration of arterioles and venules, tens of micrometers in diameter, and their motions in subcutaneous tissue could be observed.
Collapse
|
47
|
Abe Y, Chinzei T, Isoyama T, Ono T, Mabuchi K, Imanishi K, Kouno A, Atsumi K, Fujimasa I, Imachi K. Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump. Artif Organs 1995; 19:691-3. [PMID: 8572975 DOI: 10.1111/j.1525-1594.1995.tb02404.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The undulation pump (formerly called the precessional displacement pump) is a continuous flow displacement-type blood pump that is being developed as an implantable total artificial heart. A new undulation pump was developed for chronic use and was examined with animal experiment and flow visualization studies. In the animal experiment using a left ventricular bypass in goats, severe hemolysis occurred. After driving for 12 h, thrombus formation inside the pump was found. In the flow visualization studies, the flow pattern showed that the flow inside the pump was a very complicated turbulent flow. Improvement of hemolysis and thrombus formation is important to realize implantable total artificial hearts using undulation pumps.
Collapse
|
48
|
Sakai K, Toyoshima H, Bandoh T, Isoyama T. Analysis of 102 Cases of Obstructing Colorectal Cancer with Reference to Location in Colon. ACTA ACUST UNITED AC 1995. [DOI: 10.3862/jcoloproctology.48.7_566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
49
|
Abe Y, Chinzei T, Imachi K, Mabuchi K, Imanishi K, Isoyama T, Matsuura H, Senih G, Nozawa H, Kouno A. Can total artificial heart animals control their TAH by themselves? One year survival of a TAH goat using a new automatic control method (1/R control). ASAIO J 1994; 40:M506-9. [PMID: 8555567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
A total artificial heart (TAH) goat survived for 360 days on the new automatic control method (1/R control), in which the cardiac output of the TAH can be controlled through the cardiovascular center by making it function by reflecting the beta-adrenergic reaction in peripheral vascular resistance. This is thought to be the only long-term, real-time, measurable parameter by which information on the activity of the cardiovascular center can be received directly by the TAH system. In this goat, the hemodynamic parameters (RAP, AoP, and so forth) were kept within physiologic limits when control was stable, and the cardiac output was automatically increased in response to exercise, not unlike that in the natural heart. There were no abnormal blood chemical or hormone data except at end stage. Based on these results 1/R can be considered a physiologic control method for a TAH.
Collapse
|
50
|
Imachi K, Chinzei T, Abe Y, Isoyama T, Mabuchi K, Imanishi K, Baba K, Kouno A, Ono T, Kusakabe M. A new apparatus for chronic observation of the microcirculation in situ to evaluate artificial organ performance. ASAIO J 1994; 40:M757-61. [PMID: 8555617 DOI: 10.1097/00002480-199407000-00101] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Chronic study of the peripheral circulation and metabolism is very important in evaluation of artificial organ performance. However, there has been no way to observe the microcirculation in situ, chronically and continuously, without restriction. In this study, the authors developed a new apparatus that could be implanted and connected to an artificial organ that would allow continuous observation of the microcirculation while the subject is awake. The apparatus uses a charge coupled device (CCD) under a new principle: thin living tissue, such as mesentery, is put directly on a highly integrated CCD and transilluminated with a light emitting diode (LED). The vascular nets in the tissue are projected onto the CCD like a contact photograph, which is sent to a television screen and can be analyzed for motion and function. A 0.5 inch CCD with 25K pixels was used in this study. The cover glass of the CCD was removed so the tissue would be able to directly contact the CCD surface. The CCD, as well as LED, were molded with hard polyurethane as electrical insulation. The apparatus is 35 mm in diameter and 10 mm high with a micro stand for lighting with the LED, which is easy to implant in a goat or calf. The resolution of this apparatus was tested by putting a micro scale on the CCD surface. Several tenths of micrometers could be seen. In an animal experiment with a rabbit, configurations of arterioles and venules and their motions could be observed continuously for a night until the electrical insulation was broken. This method might be a strong weapon in artificial organs research.
Collapse
|