26
|
Boso G, Ke D, Korzh B, Bouilloux J, Lange N, Zbinden H. Time-resolved singlet-oxygen luminescence detection with an efficient and practical semiconductor single-photon detector. BIOMEDICAL OPTICS EXPRESS 2016; 7:211-24. [PMID: 26819830 PMCID: PMC4722905 DOI: 10.1364/boe.7.000211] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 12/17/2015] [Accepted: 12/17/2015] [Indexed: 05/03/2023]
Abstract
In clinical applications, such as PhotoDynamic Therapy, direct singlet-oxygen detection through its luminescence in the near-infrared range (1270 nm) has been a challenging task due to its low emission probability and the lack of suitable single-photon detectors. Here, we propose a practical setup based on a negative-feedback avalanche diode detector that is a viable alternative to the current state-of-the art for different clinical scenarios, especially where geometric collection efficiency is limited (e.g. fiber-based systems, confocal microscopy, scanning systems etc.). The proposed setup is characterized with Rose Bengal as a standard photosensitizer and it is used to measure the singlet-oxygen quantum yield of a new set of photosensitizers for site-selective photodynamic therapy.
Collapse
|
27
|
Pera V, Brooks DH, Niedre M. Multiplexed fluorescence tomography with spectral and temporal data: demixing with intrinsic regularization. BIOMEDICAL OPTICS EXPRESS 2016; 7:111-131. [PMID: 26819822 PMCID: PMC4722896 DOI: 10.1364/boe.7.000111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 11/25/2015] [Accepted: 12/01/2015] [Indexed: 06/05/2023]
Abstract
We consider the joint use of spectral and temporal data for multiplexed fluorescence molecular tomography to enable high-throughput imaging of multiple fluorescent targets in bulk tissue. This is a challenging problem due to the narrow near-infrared diagnostic window and relatively broad emission spectra of common fluorophores, and the distortion ("redshift") that the fluorophore signals undergo as they propagate through tissue. We show through a Cramér-Rao lower bound analysis that demixing with spectral-temporal data could result in an order of magnitude improvement in performance over either modality alone. To cope with the resulting large data set, we propose a novel two-stage algorithm that decouples the demixing and tomographic reconstruction operations. In this work we concentrate on the demixing stage. We introduce an approach which incorporates ideas from sparse subspace clustering and compressed sensing and does not require a regularization parameter. We report on simulations in which we simultaneously demixed four fluorophores with closely overlapping spectral and temporal profiles in a 25 mm diameter cross-sectional area with a root-mean-square error of less than 3% per fluorophore, as well as on studies of sensitivity of the method to model mismatch.
Collapse
|
28
|
Yao R, Pian Q, Intes X. Wide-field fluorescence molecular tomography with compressive sensing based preconditioning. BIOMEDICAL OPTICS EXPRESS 2015; 6:4887-98. [PMID: 26713202 PMCID: PMC4679262 DOI: 10.1364/boe.6.004887] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 10/15/2015] [Accepted: 10/15/2015] [Indexed: 05/18/2023]
Abstract
Wide-field optical tomography based on structured light illumination and detection strategies enables efficient tomographic imaging of large tissues at very fast acquisition speeds. However, the optical inverse problem based on such instrumental approach is still ill-conditioned. Herein, we investigate the benefit of employing compressive sensing-based preconditioning to wide-field structured illumination and detection approaches. We assess the performances of Fluorescence Molecular Tomography (FMT) when using such preconditioning methods both in silico and with experimental data. Additionally, we demonstrate that such methodology could be used to select the subset of patterns that provides optimal reconstruction performances. Lastly, we compare preconditioning data collected using a normal base that offers good experimental SNR against that directly acquired with optimal designed base. An experimental phantom study is provided to validate the proposed technique.
Collapse
|
29
|
Li J, Bower AJ, Vainstein V, Gluzman-Poltorak Z, Chaney EJ, Marjanovic M, Basile LA, Boppart SA. Effect of recombinant interleukin-12 on murine skin regeneration and cell dynamics using in vivo multimodal microscopy. BIOMEDICAL OPTICS EXPRESS 2015; 6:4277-87. [PMID: 26600994 PMCID: PMC4646538 DOI: 10.1364/boe.6.004277] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Revised: 09/20/2015] [Accepted: 09/29/2015] [Indexed: 05/04/2023]
Abstract
Interleukin-12 (IL-12) is a pro-inflammatory cytokine known for its role in immunity, and previous studies have shown that IL-12 provides mitigation of radiation injury. In this study, we utilize a multimodal microscopy system equipped with second harmonic generation (SHG) and fluorescence lifetime imaging microscopy (FLIM) to examine the effect of IL-12 on collagen structure and cellular metabolic activity in vivo during skin wound healing. This preliminary study illustrates the highly dynamic and heterogeneous in vivo microenvironment of the wounded skin. In addition, results suggest that IL-12 triggers a significantly more rapid and greater cellular metabolic response in the wounded animals. These results can elucidate insights into the response mechanism of IL-12 in both wound healing and acute radiation syndrome.
Collapse
|
30
|
Levitt JA, Morton PE, Fruhwirth GO, Santis G, Chung PH, Parsons M, Suhling K. Simultaneous FRAP, FLIM and FAIM for measurements of protein mobility and interaction in living cells. BIOMEDICAL OPTICS EXPRESS 2015; 6:3842-54. [PMID: 26504635 PMCID: PMC4605044 DOI: 10.1364/boe.6.003842] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 08/16/2015] [Accepted: 08/18/2015] [Indexed: 05/23/2023]
Abstract
We present a novel integrated multimodal fluorescence microscopy technique for simultaneous fluorescence recovery after photobleaching (FRAP), fluorescence lifetime imaging (FLIM) and fluorescence anisotropy imaging (FAIM). This approach captures a series of polarization-resolved fluorescence lifetime images during a FRAP recovery, maximizing the information available from a limited photon budget. We have applied this method to analyse the behaviour of GFP-labelled coxsackievirus and adenovirus receptor (CAR) in living human epithelial cells. Our data reveal that CAR exists in oligomeric states throughout the cell, and that these complexes occur in conjunction with high immobile fractions of the receptor at cell-cell junctions. These findings shed light on previously unknown molecular associations between CAR receptors in intact cells and demonstrate the power of combined FRAP, FLIM and FAIM microscopy as a robust method to analyse complex multi-component dynamics in living cells.
Collapse
|
31
|
Mu Y, Niedre M. Fast single photon avalanche photodiode-based time-resolved diffuse optical tomography scanner. BIOMEDICAL OPTICS EXPRESS 2015; 6:3596-3609. [PMID: 26417526 PMCID: PMC4574682 DOI: 10.1364/boe.6.003596] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Revised: 08/17/2015] [Accepted: 08/17/2015] [Indexed: 06/05/2023]
Abstract
Resolution in diffuse optical tomography (DOT) is a persistent problem and is primarily limited by high degree of light scatter in biological tissue. We showed previously that the reduction in photon scatter between a source and detector pair at early time points following a laser pulse in time-resolved DOT is highly dependent on the temporal response of the instrument. To this end, we developed a new single-photon avalanche photodiode (SPAD) based time-resolved DOT scanner. This instrument uses an array of fast SPADs, a femto-second Titanium Sapphire laser and single photon counting electronics. In combination, the overall instrument temporal impulse response function width was 59 ps. In this paper, we report the design of this instrument and validate its operation in symmetrical and irregularly shaped optical phantoms of approximately small animal size. We were able to accurately reconstruct the size and position of up to 4 absorbing inclusions, with increasing image quality at earlier time windows. We attribute these results primarily to the rapid response time of our instrument. These data illustrate the potential utility of fast SPAD detectors in time-resolved DOT.
Collapse
|
32
|
Kim B, Lee SH, Yoon CJ, Gho YS, Ahn GO, Kim KH. In vivo visualization of skin inflammation by optical coherence tomography and two-photon microscopy. BIOMEDICAL OPTICS EXPRESS 2015; 6:2512-2521. [PMID: 26203377 PMCID: PMC4505705 DOI: 10.1364/boe.6.002512] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 06/01/2015] [Accepted: 06/09/2015] [Indexed: 05/23/2023]
Abstract
Inflammation is a non-specific immune response to injury intended to protect biological tissue from harmful stimuli such as pathogens, irritants, and damaged cells. In vivo optical tissue imaging has been used to provide spatial and dynamic characteristics of inflammation within the tissue. In this paper, we report in vivo visualization of inflammation in the skin at both cellular and physiological levels by using a combination of label-free two-photon microscopy (TPM) and optical coherence tomography (OCT). Skin inflammation was induced by topically applying lipopolysaccharide (LPS) on the mouse ear. Temporal OCT imaging visualized tissue swelling, vasodilation, and increased capillary density 30 min and 1 hour after application. TPM imaging showed immune cell migration within the inflamed skin. Combined OCT and TPM was applied to obtain complementary information from each modality in the same region of interest. The information provided by each modality were consistent with previous reports about the characteristics of inflammation. Therefore, the combination of OCT and TPM holds potential for studying inflammation of the skin.
Collapse
|
33
|
Campos-Delgado DU, Navarro OG, Arce-Santana ER, Jo JA. Extended output phasor representation of multi-spectral fluorescence lifetime imaging microscopy. BIOMEDICAL OPTICS EXPRESS 2015; 6:2088-105. [PMID: 26114031 PMCID: PMC4473746 DOI: 10.1364/boe.6.002088] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Revised: 05/01/2015] [Accepted: 05/04/2015] [Indexed: 05/23/2023]
Abstract
In this paper, we investigate novel low-dimensional and model-free representations for multi-spectral fluorescence lifetime imaging microscopy (m-FLIM) data. We depart from the classical definition of the phasor in the complex plane to propose the extended output phasor (EOP) and extended phasor (EP) for multi-spectral information. The frequency domain properties of the EOP and EP are analytically studied based on a multiexponential model for the impulse response of the imaged tissue. For practical implementations, the EOP is more appealing since there is no need to perform deconvolution of the instrument response from the measured m-FLIM data, as in the case of EP. Our synthetic and experimental evaluations with m-FLIM datasets of human coronary atherosclerotic plaques show that low frequency indexes have to be employed for a distinctive representation of the EOP and EP, and to reduce noise distortion. The tissue classification of the m-FLIM datasets by EOP and EP also improves with low frequency indexes, and does not present significant differences by using either phasor.
Collapse
|
34
|
Hernández IC, Buttafava M, Boso G, Diaspro A, Tosi A, Vicidomini G. Gated STED microscopy with time-gated single-photon avalanche diode. BIOMEDICAL OPTICS EXPRESS 2015; 6:2258-67. [PMID: 26114044 PMCID: PMC4473759 DOI: 10.1364/boe.6.002258] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 05/15/2015] [Accepted: 05/17/2015] [Indexed: 05/12/2023]
Abstract
Stimulated emission depletion (STED) microscopy provides fluorescence imaging with sub-diffraction resolution. Experimentally demonstrated at the end of the 90s, STED microscopy has gained substantial momentum and impact only in the last few years. Indeed, advances in many fields improved its compatibility with everyday biological research. Among them, a fundamental step was represented by the introduction in a STED architecture of the time-gated detection, which greatly reduced the complexity of the implementation and the illumination intensity needed. However, the benefits of the time-gated detection came along with a reduction of the fluorescence signal forming the STED microscopy images. The maximization of the useful (within the time gate) photon flux is then an important aspect to obtain super-resolved images. Here we show that by using a fast-gated single-photon avalanche diode (SPAD), i.e. a detector able to rapidly (hundreds picoseconds) switch-on and -off can improve significantly the signal-to-noise ratio (SNR) of the gated STED image. In addition to an enhancement of the image SNR, the use of the fast-gated SPAD reduces also the system complexity. We demonstrate these abilities both on calibration and biological sample. The experiments were carried on a gated STED microscope based on a STED beam operating in continuous-wave (CW), although the fast-gated SPAD is fully compatible with gated STED implementations based on pulsed STED beams.
Collapse
|
35
|
Haidar DA, Leh B, Zanello M, Siebert R. Spectral and lifetime domain measurements of rat brain tumors. BIOMEDICAL OPTICS EXPRESS 2015; 6:1219-33. [PMID: 25909006 PMCID: PMC4399661 DOI: 10.1364/boe.6.001219] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2015] [Revised: 02/20/2015] [Accepted: 02/22/2015] [Indexed: 05/12/2023]
Abstract
During glioblastoma surgery, delineation of the brain tumor margins is difficult because the infiltrated and normal tissues have the same visual appearance. We use a fiber-optical fluorescence probe for spectroscopic and time domain measurements to assist surgeon in differentiating the healthy and the infiltrated tissues. First study was performed on rats that were previously injected with tumorous cells. Measurements of endogenous tissue fluorescence were performed on fresh and fixed rat tumor brain slices. Spectral characteristics, fluorescence redox ratios and fluorescence lifetime measurements were analyzed. The study aimed at defining an optical index that can act as an indicator for discriminating healthy from tumorous tissue.
Collapse
|
36
|
Chen L, Alexandrov Y, Kumar S, Andrews N, Dallman MJ, French PMW, McGinty J. Mesoscopic in vivo 3-D tracking of sparse cell populations using angular multiplexed optical projection tomography. BIOMEDICAL OPTICS EXPRESS 2015; 6:1253-1261. [PMID: 25909009 PMCID: PMC4399664 DOI: 10.1364/boe.6.001253] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 12/23/2014] [Accepted: 12/25/2014] [Indexed: 05/29/2023]
Abstract
We describe an angular multiplexed imaging technique for 3-D in vivo cell tracking of sparse cell distributions and optical projection tomography (OPT) with superior time-lapse resolution and a significantly reduced light dose compared to volumetric time-lapse techniques. We demonstrate that using dual axis OPT, where two images are acquired simultaneously at different projection angles, can enable localization and tracking of features in 3-D with a time resolution equal to the camera frame rate. This is achieved with a 200x reduction in light dose compared to an equivalent volumetric time-lapse single camera OPT acquisition with 200 projection angles. We demonstrate the application of this technique to mapping the 3-D neutrophil migration pattern observed over ~25.5 minutes in a live 2 day post-fertilisation transgenic LysC:GFP zebrafish embryo following a tail wound.
Collapse
|
37
|
Walsh AJ, Skala MC. Optical metabolic imaging quantifies heterogeneous cell populations. BIOMEDICAL OPTICS EXPRESS 2015; 6:559-73. [PMID: 25780745 PMCID: PMC4354590 DOI: 10.1364/boe.6.000559] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 01/07/2015] [Accepted: 01/09/2015] [Indexed: 05/20/2023]
Abstract
The genetic and phenotypic heterogeneity of cancers can contribute to tumor aggressiveness, invasion, and resistance to therapy. Fluorescence imaging occupies a unique niche to investigate tumor heterogeneity due to its high resolution and molecular specificity. Here, heterogeneous populations are identified and quantified by combined optical metabolic imaging and subpopulation analysis (OMI-SPA). OMI probes the fluorescence intensities and lifetimes of metabolic enzymes in cells to provide images of cellular metabolism, and SPA models cell populations as mixed Gaussian distributions to identify cell subpopulations. In this study, OMI-SPA is characterized by simulation experiments and validated with cell experiments. To generate heterogeneous populations, two breast cancer cell lines, SKBr3 and MDA-MB-231, were co-cultured at varying proportions. OMI-SPA correctly identifies two populations with minimal mean and proportion error using the optical redox ratio (fluorescence intensity of NAD(P)H divided by the intensity of FAD), mean NAD(P)H fluorescence lifetime, and OMI index. Simulation experiments characterized the relationships between sample size, data standard deviation, and subpopulation mean separation distance required for OMI-SPA to identify subpopulations.
Collapse
|
38
|
Bonomini V, Zucchelli L, Re R, Ieva F, Spinelli L, Contini D, Paganoni A, Torricelli A. Linear regression models and k-means clustering for statistical analysis of fNIRS data. BIOMEDICAL OPTICS EXPRESS 2015; 6:615-30. [PMID: 25780751 PMCID: PMC4354588 DOI: 10.1364/boe.6.000615] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Revised: 01/17/2015] [Accepted: 01/22/2015] [Indexed: 05/10/2023]
Abstract
We propose a new algorithm, based on a linear regression model, to statistically estimate the hemodynamic activations in fNIRS data sets. The main concern guiding the algorithm development was the minimization of assumptions and approximations made on the data set for the application of statistical tests. Further, we propose a K-means method to cluster fNIRS data (i.e. channels) as activated or not activated. The methods were validated both on simulated and in vivo fNIRS data. A time domain (TD) fNIRS technique was preferred because of its high performances in discriminating cortical activation and superficial physiological changes. However, the proposed method is also applicable to continuous wave or frequency domain fNIRS data sets.
Collapse
|
39
|
Puszka A, Di Sieno L, Mora AD, Pifferi A, Contini D, Planat-Chrétien A, Koenig A, Boso G, Tosi A, Hervé L, Dinten JM. Spatial resolution in depth for time-resolved diffuse optical tomography using short source-detector separations. BIOMEDICAL OPTICS EXPRESS 2015; 6:1-10. [PMID: 25657869 PMCID: PMC4317114 DOI: 10.1364/boe.6.000001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Revised: 11/07/2014] [Accepted: 11/07/2014] [Indexed: 05/20/2023]
Abstract
Diffuse optical tomography for medical applications can require probes with small dimensions involving short source-detector separations. Even though this configuration is seen at first as a constraint due to the challenge of depth sensitivity, we show here that it can potentially be an asset for spatial resolution in depth. By comparing two fiber optic probes on a test object, we first show with simulations that short source-detector separations improve the spatial resolution down to a limit depth. We then confirm these results in an experimental study with a state-of-the-art setup involving a fast-gated single-photon avalanche diode allowing maximum depth sensitivity. We conclude that short source-detector separations are an option to consider for the design of probes so as to improve image quality for diffuse optical tomography in reflectance.
Collapse
|
40
|
Quarto G, Spinelli L, Pifferi A, Torricelli A, Cubeddu R, Abbate F, Balestreri N, Menna S, Cassano E, Taroni P. Estimate of tissue composition in malignant and benign breast lesions by time-domain optical mammography. BIOMEDICAL OPTICS EXPRESS 2014; 5:3684-98. [PMID: 25360382 PMCID: PMC4206334 DOI: 10.1364/boe.5.003684] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 09/10/2014] [Accepted: 09/11/2014] [Indexed: 05/03/2023]
Abstract
The optical characterization of malignant and benign breast lesions is presented. Time-resolved transmittance measurements were performed in the 630-1060 nm range by means of a 7-wavelength optical mammograph, providing both imaging and spectroscopy information. A total of 62 lesions were analyzed, including 33 malignant and 29 benign lesions. The characterization of breast lesions was performed applying a perturbation model based on the high-order calculation of the pathlength of photons inside the lesion, which led to the assessment of oxy- and deoxy-hemoglobin, lipids, water and collagen concentrations. Significant variations between tumor and healthy tissue were observed in terms of both absorption properties and constituents concentration. In particular, benign lesions and tumors show a statistically significant discrimination in terms of absorption at several wavelengths and also in terms of oxy-hemoglobin and collagen content.
Collapse
|
41
|
Martens MA, Boesmans W, Vanden Berghe P. Calcium imaging at kHz frame rates resolves millisecond timing in neuronal circuits and varicosities. BIOMEDICAL OPTICS EXPRESS 2014; 5:2648-2661. [PMID: 25136492 PMCID: PMC4132995 DOI: 10.1364/boe.5.002648] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 07/10/2014] [Accepted: 07/11/2014] [Indexed: 06/03/2023]
Abstract
We have configured a widefield fast imaging system that allows imaging at 1000 frames per second (512x512 pixels). The system was extended with custom processing tools including a time correlation method to facilitate the analysis of static subcellular compartments (e.g. neuronal varicosities) with enhanced contrast, as well as a dynamic intensity processing (DIP) algorithm that aids in data size reduction and fast visualization and interpretation of timing and directionality in neuronal circuits. This system, together with our custom developed processing tools enables efficient detection of fast physiological events, such as action potential dependent calcium steps. We show, using a specific blocker of nerve communication, that with this setup it is possible to discriminate between a pre and post synaptic event in an all optical way.
Collapse
|
42
|
Jelzow A, Wabnitz H, Tachtsidis I, Kirilina E, Brühl R, Macdonald R. Separation of superficial and cerebral hemodynamics using a single distance time-domain NIRS measurement. BIOMEDICAL OPTICS EXPRESS 2014; 5:1465-82. [PMID: 24877009 PMCID: PMC4026903 DOI: 10.1364/boe.5.001465] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 03/13/2014] [Accepted: 03/24/2014] [Indexed: 05/09/2023]
Abstract
In functional near-infrared spectroscopy (fNIRS) superficial hemodynamics can mask optical signals related to brain activity. We present a method to separate superficial and cerebral absorption changes based on the analysis of changes in moments of time-of-flight distributions and a two-layered model. The related sensitivity factors were calculated from individual optical properties. The method was validated on a two-layer liquid phantom. Absorption changes in the lower layer were retrieved with an accuracy better than 20%. The method was successfully applied to in vivo data and compared to the reconstruction of homogeneous absorption changes.
Collapse
|
43
|
Zhao L, Abe K, Rajoria S, Pian Q, Barroso M, Intes X. Spatial light modulator based active wide-field illumination for ex vivo and in vivo quantitative NIR FRET imaging. BIOMEDICAL OPTICS EXPRESS 2014; 5:944-60. [PMID: 24688826 PMCID: PMC3959842 DOI: 10.1364/boe.5.000944] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 01/20/2014] [Accepted: 01/31/2014] [Indexed: 05/20/2023]
Abstract
Fluorescence lifetime imaging is playing an increasing role in drug development by providing a sensitive method to monitor drug delivery and receptor-ligand interactions. However, the wide dynamic range of fluorescence intensity emitted by ex vivo and in vivo samples presents challenges in retrieving information over the whole subject accurately and quantitatively. To overcome this challenge, we developed an active wide-field illumination (AWFI) strategy based on a spatial light modulator that acquires optimal fluorescence signals by enhancing the dynamic range, signal to noise ratio, and estimation of lifetime-based parameters. We demonstrate the ability of AWFI to estimate Förster resonance energy transfer (FRET) donor fraction from dissected organs with high accuracy (standard deviation <6%) over the whole field of view, in contrast with the homogenous wide-field illumination. We further report its successful application to quantitative FRET imaging in a live mouse. AWFI allows improved detection of weak signals and enhanced quantitative accuracy in ex vivo and in vivo molecular fluorescence quantitative imaging. The technique allows for robust quantitative estimation of the bio-distribution of molecular probes and lifetime-based parameters over an extended imaging field exhibiting a large range of fluorescence intensities and at a high acquisition speed (less than 1 min).
Collapse
|
44
|
Mazurenka M, Di Sieno L, Boso G, Contini D, Pifferi A, Mora AD, Tosi A, Wabnitz H, Macdonald R. Non-contact in vivo diffuse optical imaging using a time-gated scanning system. BIOMEDICAL OPTICS EXPRESS 2013; 4:2257-68. [PMID: 24156081 PMCID: PMC3799683 DOI: 10.1364/boe.4.002257] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Revised: 09/21/2013] [Accepted: 09/22/2013] [Indexed: 05/19/2023]
Abstract
We report on the design and first in vivo tests of a novel non-contact scanning imaging system for time-domain near-infrared spectroscopy. Our system is based on a null source-detector separation approach and utilizes polarization-selective detection and a fast-gated single-photon avalanche diode to record late photons only. The in-vivo tests included the recording of hemodynamics during arm occlusion and two brain activation tasks. Localized and non-localized changes in oxy- and deoxyhemoglobin concentration were detected for motor and cognitive tasks, respectively. The tests demonstrate the feasibility of non-contact imaging of absorption changes in deeper tissues.
Collapse
|
45
|
Re R, Contini D, Turola M, Spinelli L, Zucchelli L, Caffini M, Cubeddu R, Torricelli A. Multi-channel medical device for time domain functional near infrared spectroscopy based on wavelength space multiplexing. BIOMEDICAL OPTICS EXPRESS 2013; 4:2231-46. [PMID: 24156079 PMCID: PMC3799681 DOI: 10.1364/boe.4.002231] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 09/12/2013] [Accepted: 09/17/2013] [Indexed: 05/03/2023]
Abstract
We have designed a compact dual wavelength (687 nm, 826 nm) multi-channel (16 sources, 8 detectors) medical device for muscle and brain imaging based on time domain functional near infrared spectroscopy. The system employs the wavelength space multiplexing approach to reduce wavelength cross-talk and increase signal-to-noise ratio. System performances have been tested on homogeneous and heterogeneous tissue phantoms following specifically designed protocols for photon migration instruments. Preliminary in vivo measurements have been performed to validate the instrument capability to monitor hemodynamic parameters changes in the arm muscle during arterial occlusion and in the adult head during a motor task experiment.
Collapse
|
46
|
Gohar AV, Cao R, Jenkins P, Li W, Houston JP, Houston KD. Subcellular localization-dependent changes in EGFP fluorescence lifetime measured by time-resolved flow cytometry. BIOMEDICAL OPTICS EXPRESS 2013; 4:1390-400. [PMID: 24010001 PMCID: PMC3756581 DOI: 10.1364/boe.4.001390] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2013] [Revised: 07/11/2013] [Accepted: 07/15/2013] [Indexed: 05/23/2023]
Abstract
Intracellular protein transport and localization to subcellular regions are processes necessary for normal protein function. Fluorescent proteins can be fused to proteins of interest to track movement and determine localization within a cell. Currently, fluorescence microscopy combined with image processing is most often used to study protein movement and subcellular localization. In this contribution we evaluate a high-throughput time-resolved flow cytometry approach to correlate intracellular localization of human LC3 protein with the fluorescence lifetime of enhanced green fluorescent protein (EGFP). Subcellular LC3 localization to autophagosomes is a marker of the cellular process called autophagy. In breast cancer cells expressing native EGFP and EGFP-LC3 fusion proteins, we measured the fluorescence intensity and lifetime of (i) diffuse EGFP (ii) punctate EGFP-LC3 and (iii) diffuse EGFP-ΔLC3 after amino acid starvation to induce autophagy-dependent LC3 localization. We verify EGFP-LC3 localization with low-throughput confocal microscopy and compare to fluorescence intensity measured by standard flow cytometry. Our results demonstrate that time-resolved flow cytometry can be correlated to subcellular localization of EGFP fusion proteins by measuring changes in fluorescence lifetime.
Collapse
|
47
|
Puszka A, Hervé L, Planat-Chrétien A, Koenig A, Derouard J, Dinten JM. Time-domain reflectance diffuse optical tomography with Mellin-Laplace transform for experimental detection and depth localization of a single absorbing inclusion. BIOMEDICAL OPTICS EXPRESS 2013; 4:569-83. [PMID: 23577292 PMCID: PMC3617719 DOI: 10.1364/boe.4.000569] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2012] [Revised: 01/07/2013] [Accepted: 01/08/2013] [Indexed: 05/18/2023]
Abstract
We show how to apply the Mellin-Laplace transform to process time-resolved reflectance measurements for diffuse optical tomography. We illustrate this method on simulated signals incorporating the main sources of experimental noise and suggest how to fine-tune the method in order to detect the deepest absorbing inclusions and optimize their localization in depth, depending on the dynamic range of the measurement. To finish, we apply this method to measurements acquired with a setup including a femtosecond laser, photomultipliers and a time-correlated single photon counting board. Simulations and experiments are illustrated for a probe featuring the interfiber distance of 1.5 cm and show the potential of time-resolved techniques for imaging absorption contrast in depth with this geometry.
Collapse
|
48
|
Elliott JT, Milej D, Gerega A, Weigl W, Diop M, Morrison LB, Lee TY, Liebert A, St. Lawrence K. Variance of time-of-flight distribution is sensitive to cerebral blood flow as demonstrated by ICG bolus-tracking measurements in adult pigs. BIOMEDICAL OPTICS EXPRESS 2013; 4:206-18. [PMID: 23413183 PMCID: PMC3567707 DOI: 10.1364/boe.4.000206] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 10/22/2012] [Accepted: 11/20/2012] [Indexed: 05/03/2023]
Abstract
Variance of time-of-flight distributions have been shown to be more sensitive to cerebral blood flow (CBF) during dynamic-contrast enhanced monitoring of neurotrauma patients than attenuation. What is unknown is the degree to which variance is affected by changes in extracerebral blood flow. Furthermore, the importance of acquiring the arterial input function (AIF) on quantitative analysis of the data is not yet clear. This animal study confirms that variance is both sensitive and specific to changes occurring in the brain when measurements are acquired on the surface of the scalp. Furthermore, when the variance data along with the measured AIF is analyzed using a nonparametric deconvolution method, the recovered change in CBF is in good agreement with CT perfusion values.
Collapse
|
49
|
Zhang W, Wu L, Li J, Yi X, Wang X, Lu Y, Chen W, Zhou Z, Zhang L, Zhao H, Gao F. Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology. BIOMEDICAL OPTICS EXPRESS 2013; 4:331-48. [PMID: 23412647 PMCID: PMC3567719 DOI: 10.1364/boe.4.000331] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 01/21/2013] [Accepted: 01/23/2013] [Indexed: 05/14/2023]
Abstract
A combined time-domain fluorescence and hemoglobin diffuse optical tomography (DOT) system and the image reconstruction methods are proposed for enhancing the reliability of breast-dedicated optical measurement. The system equipped with two pulsed laser diodes at wavelengths of 780 nm and 830 nm that are specific to the peak excitation and emission of the FDA-approved ICG agent, and works with a 4-channel time-correlated single photon counting device to acquire the time-resolved distributions of the light re-emissions at 32 boundary sites of tissues in a tandem serial-to-parallel mode. The simultaneous reconstruction of the two optical (absorption and scattering) and two fluorescent (yield and lifetime) properties are achieved with the respective featured-data algorithms based on the generalized pulse spectrum technique. The performances of the methodology are experimentally assessed on breast-mimicking phantoms for hemoglobin- and fluorescence-DOT alone, as well as for fluorescence-guided hemoglobin-DOT. The results demonstrate the efficacy of improving the accuracy of hemoglobin-DOT based on a priori fluorescence localization.
Collapse
|
50
|
Zucchelli L, Contini D, Re R, Torricelli A, Spinelli L. Method for the discrimination of superficial and deep absorption variations by time domain fNIRS. BIOMEDICAL OPTICS EXPRESS 2013; 4:2893-910. [PMID: 24409389 PMCID: PMC3862167 DOI: 10.1364/boe.4.002893] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 11/08/2013] [Accepted: 11/12/2013] [Indexed: 05/03/2023]
Abstract
A method for the discrimination of superficial and deep absorption variations by time domain functional near infrared spectroscopy is presented. The method exploits the estimate of the photon time-dependent pathlength in different domains of the sampled medium and makes use of an approach based on time-gating of the photon distribution of time-of-flights. Validation of the method is performed in the two-layer geometry to focus on muscle and head applications. Numerical simulations varied the thickness of the upper layer, the interfiber distance, the shape of the instrument response function and the photon counts. Preliminary results from in vivo data are also shown.
Collapse
|