26
|
Song W, Yin W, Zhang Z, He P, Yang X, Zhang X. A DNA functionalized porphyrinic metal-organic framework as a peroxidase mimicking catalyst for amperometric determination of the activity of T4 polynucleotide kinase. Mikrochim Acta 2019; 186:149. [PMID: 30712077 DOI: 10.1007/s00604-019-3269-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Accepted: 01/18/2019] [Indexed: 11/27/2022]
Abstract
An electrochemical method is described for the sensitive detection of the activity of the enzyme T4 polynucleotide kinase (PNK) by using a DNA functionalized porphyrinic metal-organic framework (L/(Fe-P)n-MOF). In the presence of PNK, the hairpin oligonucleotide (HP1) becomes phosphorylated, and the trigger is released by lambda exonuclease (λ exo). The trigger DNA hybridizes with hairpin probe (immobilized on the gold electrode) to form a nicking endonuclease cleavage site. Thus, a single-strand capture probe is employed to hybridize with L/(Fe-P)n-MOF. The (Fe-P)n-MOF is a peroxidase mimicking material with high catalytic efficiency. By using this amplification strategy, an electrochemical signal is procured that allows for the determination of T4 PNK in the 1.0 mU·mL-1 to 1.0 U·mL-1 with a detection limit of 0.62 mU·mL-1. The method is selective and can be used to screen for enzyme inhibitors. Conceivably, the (Fe-P)n-MOF can also be used to detect other analytes via its peroxidase-mimicking activity. Graphical abstract Schematic presentation of T4 polynucleotide kinase (PNK) detection. Two hairpin DNAs (HP) and a porphyrinic metal-organic framework with peroxidase-mimicking activity are used. The detection limit is 0.62 mU mL-1 with enzyme assisted signal amplification. This method is selective and can be used to screen for enzyme inhibitors.
Collapse
|
27
|
Vukomanovic M, Torrents E. High time resolution and high signal-to-noise monitoring of the bacterial growth kinetics in the presence of plasmonic nanoparticles. J Nanobiotechnology 2019; 17:21. [PMID: 30709404 PMCID: PMC6357367 DOI: 10.1186/s12951-019-0459-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 01/21/2019] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Emerging concepts for designing innovative drugs (i.e., novel generations of antimicrobials) frequently include nanostructures, new materials, and nanoparticles (NPs). Along with numerous advantages, NPs bring limitations, partly because they can limit the analytical techniques used for their biological and in vivo validation. From that standpoint, designing innovative drug delivery systems requires advancements in the methods used for their testing and investigations. Considering the well-known ability of resazurin-based methods for rapid detection of bacterial metabolisms with very high sensitivity, in this work we report a novel optimization for tracking bacterial growth kinetics in the presence of NPs with specific characteristics, such as specific optical properties. RESULTS Arginine-functionalized gold composite (HAp/Au/arginine) NPs, used as the NP model for validation of the method, possess plasmonic properties and are characterized by intensive absorption in the UV/vis region with a surface plasmon resonance maximum at 540 nm. Due to the specific optical properties, the NP absorption intensively interferes with the light absorption measured during the evaluation of bacterial growth (optical density; OD600). The results confirm substantial nonspecific interference by NPs in the signal detected during a regular turbidity study used for tracking bacterial growth. Instead, during application of a resazurin-based method (Presto Blue), when a combination of absorption and fluorescence detection is applied, a substantial increase in the signal-to-noise ratio is obtained that leads to the improvement of the accuracy of the measurements as verified in three bacterial strains tested with different growth rates (E. coli, P. aeruginosa, and S. aureus). CONCLUSIONS Here, we described a novel procedure that enables the kinetics of bacterial growth in the presence of NPs to be followed with high time resolution, high sensitivity, and without sampling during the kinetic study. We showed the applicability of the Presto Blue method for the case of HAp/Au/arginine NPs, which can be extended to various types of metallic NPs with similar characteristics. The method is a very easy, economical, and reliable option for testing NPs designed as novel antimicrobials.
Collapse
|
28
|
Kahanda D, Singh N, Boothman DA, Slinker JD. Following anticancer drug activity in cell lysates with DNA devices. Biosens Bioelectron 2018; 119:1-9. [PMID: 30098460 PMCID: PMC6217983 DOI: 10.1016/j.bios.2018.07.059] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 07/20/2018] [Accepted: 07/28/2018] [Indexed: 11/19/2022]
Abstract
There is a great need to track the selectivity of anticancer drug activity and to understand the mechanisms of associated biological activity. Here we focus our studies on the specific NQO1 bioactivatable drug, ß-lapachone, which is in several Phase I clinical trials to treat human non-small cell lung, pancreatic and breast cancers. Multi-electrode chips with electrochemically-active DNA monolayers are used to track anticancer drug activity in cellular lysates and correlate cell death activity with DNA damage. Cells were prepared from the triple-negative breast cancer (TNBC) cell line, MDA-MB-231 (231) to be proficient or deficient in expression of the NAD(P)H:quinone oxidoreductase 1 (NQO1) enzyme, which is overexpressed in most solid cancers and lacking in control healthy cells. Cells were lysed and added to chips, and the impact of β-lapachone (β-lap), an NQO1-dependent DNA-damaging drug, was tracked with DNA electrochemical signal changes arising from drug-induced DNA damage. Electrochemical DNA devices showed a 3.7-fold difference in the electrochemical responses in NQO1+ over NQO1- cell lysates, as well as 10-20-fold selectivity to catalase and dicoumarol controls that deactivate DNA damaging pathways. Concentration-dependence studies revealed that 1.4 µM β-lap correlated with the onset of cell death from viability assays and the midpoint of DNA damage on the chip, and 2.5 µM β-lap correlated with the midpoint of cell death and the saturation of DNA damage on the chip. Results indicate that these devices could inform therapeutic decisions for cancer treatment.
Collapse
|
29
|
Campuzano S, Yáñez-Sedeño P, Pingarrón JM. Molecular Biosensors for Electrochemical Detection of Infectious Pathogens in Liquid Biopsies: Current Trends and Challenges. SENSORS 2017; 17:s17112533. [PMID: 29099764 PMCID: PMC5712848 DOI: 10.3390/s17112533] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Revised: 10/18/2017] [Accepted: 11/01/2017] [Indexed: 01/10/2023]
Abstract
Rapid and reliable diagnosis of infectious diseases caused by pathogens, and timely initiation of appropriate treatment are critical determinants to promote optimal clinical outcomes and general public health. Conventional in vitro diagnostics for infectious diseases are time-consuming and require centralized laboratories, experienced personnel and bulky equipment. Recent advances in electrochemical affinity biosensors have demonstrated to surpass conventional standards in regards to time, simplicity, accuracy and cost in this field. The tremendous potential offered by electrochemical affinity biosensors to detect on-site infectious pathogens at clinically relevant levels in scarcely treated body fluids is clearly stated in this review. The development and application of selected examples using different specific receptors, assay formats and electrochemical approaches focusing on the determination of specific circulating biomarkers of different molecular (genetic, regulatory and functional) levels associated with bacterial and viral pathogens are critically discussed. Existing challenges still to be addressed and future directions in this rapidly advancing and highly interesting field are also briefly pointed out.
Collapse
|
30
|
Peterson RD, Wilund KR, Cunningham BT, Andrade JE. Comparison of Methods Study between a Photonic Crystal Biosensor and Certified ELISA to Measure Biomarkers of Iron Deficiency in Chronic Kidney Disease Patients. SENSORS 2017; 17:s17102203. [PMID: 28946680 PMCID: PMC5677296 DOI: 10.3390/s17102203] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 09/21/2017] [Accepted: 09/22/2017] [Indexed: 12/30/2022]
Abstract
The total analytical error of a photonic crystal (PC) biosensor in the determination of ferritin and soluble transferrin receptor (sTfR) as biomarkers of iron deficiency anemia in chronic kidney disease (CKD) patients was evaluated against certified ELISAs. Antigens were extracted from sera of CKD patients using functionalized iron-oxide nanoparticles (fAb-IONs) followed by magnetic separation. Immuno-complexes were recognized by complementary detection Ab affixed to the PC biosensor surface, and their signals were followed using the BIND instrument. Quantification was conducted against actual protein standards. Total calculated error (TEcalc) was estimated based on systematic (SE) and random error (RE) and compared against total allowed error (TEa) based on established quality specifications. Both detection platforms showed adequate linearity, specificity, and sensitivity for biomarkers. Means, SD, and CV were similar between biomarkers for both detection platforms. Compared to ELISA, inherent imprecision was higher on the PC biosensor for ferritin, but not for sTfR. High SE or RE in the PC biosensor when measuring either biomarker resulted in TEcalc higher than the TEa. This did not influence the diagnostic ability of the PC biosensor to discriminate CKD patients with low iron stores. The performance of the PC biosensor is similar to certified ELISAs; however, optimization is required to reduce TEcalc.
Collapse
|
31
|
Bustamante López SC, Meissner KE. Characterization of carrier erythrocytes for biosensing applications. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:91510. [PMID: 28384789 DOI: 10.1117/1.jbo.22.9.091510] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 03/09/2017] [Indexed: 06/07/2023]
Abstract
Erythrocyte abundance, mobility, and carrying capacity make them attractive as a platform for blood analyte sensing as well as for drug delivery. Sensor-loaded erythrocytes, dubbed erythrosensors, could be reinfused into the bloodstream, excited noninvasively through the skin, and used to provide measurement of analyte levels in the bloodstream. Several techniques to load erythrocytes, thus creating carrier erythrocytes, exist. However, their cellular characteristics remain largely unstudied. Changes in cellular characteristics lead to removal from the bloodstream. We hypothesize that erythrosensors need to maintain native erythrocytes’ (NEs) characteristics to serve as a long-term sensing platform. Here, we investigate two loading techniques and the properties of the resulting erythrosensors. For loading, hypotonic dilution requires a hypotonic solution while electroporation relies on electrical pulses to perforate the erythrocyte membrane. We analyze the resulting erythrosensor signal, size, morphology, and hemoglobin content. Although the resulting erythrosensors exhibit morphological changes, their size was comparable with NEs. The hypotonic dilution technique was found to load erythrosensors much more efficiently than electroporation, and the sensors were loaded throughout the volume of the erythrosensors. Finally, both techniques resulted in significant loss of hemoglobin. This study points to the need for continued development of loading techniques that better preserve NE characteristics.
Collapse
|
32
|
Sinibaldi A, Sampaoli C, Danz N, Munzert P, Sonntag F, Centola F, Occhicone A, Tremante E, Giacomini P, Michelotti F. Bloch Surface Waves Biosensors for High Sensitivity Detection of Soluble ERBB2 in a Complex Biological Environment. BIOSENSORS-BASEL 2017; 7:bios7030033. [PMID: 28817097 PMCID: PMC5618039 DOI: 10.3390/bios7030033] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/11/2017] [Accepted: 08/15/2017] [Indexed: 01/24/2023]
Abstract
We report on the use of one-dimensional photonic crystals to detect clinically relevant concentrations of the cancer biomarker ERBB2 in cell lysates. Overexpression of the ERBB2 protein is associated with aggressive breast cancer subtypes. To detect soluble ERBB2, we developed an optical set-up which operates in both label-free and fluorescence modes. The detection approach makes use of a sandwich assay, in which the one-dimensional photonic crystals sustaining Bloch surface waves are modified with monoclonal antibodies, in order to guarantee high specificity during the biological recognition. We present the results of exemplary protein G based label-free assays in complex biological matrices, reaching an estimated limit of detection of 0.5 ng/mL. On-chip and chip-to-chip variability of the results is addressed too, providing repeatability rates. Moreover, results on fluorescence operation demonstrate the capability to perform high sensitive cancer biomarker assays reaching a resolution of 0.6 ng/mL, without protein G assistance. The resolution obtained in both modes meets international guidelines and recommendations (15 ng/mL) for ERBB2 quantification assays, providing an alternative tool to phenotype and diagnose molecular cancer subtypes.
Collapse
|
33
|
Bally L, Thabit H, Hovorka R. Closed-loop for type 1 diabetes - an introduction and appraisal for the generalist. BMC Med 2017; 15:14. [PMID: 28114938 PMCID: PMC5260117 DOI: 10.1186/s12916-017-0794-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 01/12/2017] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Rapid progress over the past decade has been made with the development of the 'Artificial Pancreas', also known as the closed-loop system, which emulates the feedback glucose-responsive functionality of the pancreatic beta cell. The recent FDA approval of the first hybrid closed-loop system makes the Artificial Pancreas a realistic therapeutic option for people with type 1 diabetes. In anticipation of its advent into clinical care, we provide a primer and appraisal of this novel therapeutic approach in type 1 diabetes for healthcare professionals and non-specialists in the field. DISCUSSION Randomised clinical studies in outpatient and home settings have shown improved glycaemic outcomes, reduced risk of hypoglycaemia and positive user attitudes. User input and interaction with existing closed-loop systems, however, are still required. Therefore, management of user expectations, as well as training and support by healthcare providers are key to ensure optimal uptake, satisfaction and acceptance of the technology. An overview of closed-loop technology and its clinical implications are discussed, complemented by our extensive hands-on experience with closed-loop system use during free daily living. CONCLUSIONS The introduction of the artificial pancreas into clinical practice represents a milestone towards the goal of improving the care of people with type 1 diabetes. There remains a need to understand the impact of user interaction with the technology, and its implication on current diabetes management and care.
Collapse
|
34
|
Abstract
Bacteria live in an ever changing environment and, to adapt their physiology, they have to sense the changes. Our current understanding of the mechanisms and elements involved in the detection and processing of these environmental signals grant us access to an array of genetic components able to process such information. As engineers can use different electronic components to build a circuit, we can rewire the cellular components to create digital logic and analogue gene circuits that will program cell behaviour in a designed manner in response to a specific stimulus. Here we present the methods and protocols for designing and implementing synthetic cell-based biosensors that use engineered genetic logic and analogue amplifying circuits to significantly increase selectivity and sensitivity, for example, for heavy metal ions in an aqueous environment. The approach is modular and can be readily applied to improving the sensing limit and performance of a range of microbial cell-based sensors to meet their real world detection requirement.
Collapse
|
35
|
Esfandiari L, Wang S, Wang S, Banda A, Lorenzini M, Kocharyan G, Monbouquette HG, Schmidt JJ. PCR-Independent Detection of Bacterial Species-Specific 16S rRNA at 10 fM by a Pore-Blockage Sensor. BIOSENSORS-BASEL 2016; 6:bios6030037. [PMID: 27455337 PMCID: PMC5039656 DOI: 10.3390/bios6030037] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 07/08/2016] [Accepted: 07/15/2016] [Indexed: 11/16/2022]
Abstract
A PCR-free, optics-free device is used for the detection of Escherichia coli (E. coli) 16S rRNA at 10 fM, which corresponds to ~100-1000 colony forming units/mL (CFU/mL) depending on cellular rRNA levels. The development of a rapid, sensitive, and cost-effective nucleic acid detection platform is sought for the detection of pathogenic microbes in food, water and body fluids. Since 16S rRNA sequences are species specific and are present at high copy number in viable cells, these nucleic acids offer an attractive target for microbial pathogen detection schemes. Here, target 16S rRNA of E. coli at 10 fM concentration was detected against a total RNA background using a conceptually simple approach based on electromechanical signal transduction, whereby a step change reduction in ionic current through a pore indicates blockage by an electrophoretically mobilized bead-peptide nucleic acid probe conjugate hybridized to target nucleic acid. We investigated the concentration detection limit for bacterial species-specific 16S rRNA at 1 pM to 1 fM and found a limit of detection of 10 fM for our device, which is consistent with our previous finding with single-stranded DNA of similar length. In addition, no false positive responses were obtained with control RNA and no false negatives with target 16S rRNA present down to the limit of detection (LOD) of 10 fM. Thus, this detection scheme shows promise for integration into portable, low-cost systems for rapid detection of pathogenic microbes in food, water and body fluids.
Collapse
|
36
|
Kamakoti V, Panneer Selvam A, Radha Shanmugam N, Muthukumar S, Prasad S. Flexible Molybdenum Electrodes towards Designing Affinity Based Protein Biosensors. BIOSENSORS 2016; 6:E36. [PMID: 27438863 PMCID: PMC5039655 DOI: 10.3390/bios6030036] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2016] [Revised: 07/01/2016] [Accepted: 07/11/2016] [Indexed: 12/25/2022]
Abstract
Molybdenum electrode based flexible biosensor on porous polyamide substrates has been fabricated and tested for its functionality as a protein affinity based biosensor. The biosensor performance was evaluated using a key cardiac biomarker; cardiac Troponin-I (cTnI). Molybdenum is a transition metal and demonstrates electrochemical behavior upon interaction with an electrolyte. We have leveraged this property of molybdenum for designing an affinity based biosensor using electrochemical impedance spectroscopy. We have evaluated the feasibility of detection of cTnI in phosphate-buffered saline (PBS) and human serum (HS) by measuring impedance changes over a frequency window from 100 mHz to 1 MHz. Increasing changes to the measured impedance was correlated to the increased dose of cTnI molecules binding to the cTnI antibody functionalized molybdenum surface. We achieved cTnI detection limit of 10 pg/mL in PBS and 1 ng/mL in HS medium. The use of flexible substrates for designing the biosensor demonstrates promise for integration with a large-scale batch manufacturing process.
Collapse
|
37
|
Vaidyanathan S, Cherng JY, Sun AC, Chen CY. Bacteria-Templated NiO Nanoparticles/Microstructure for an Enzymeless Glucose Sensor. Int J Mol Sci 2016; 17:ijms17071104. [PMID: 27409615 PMCID: PMC4964480 DOI: 10.3390/ijms17071104] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 06/24/2016] [Accepted: 06/28/2016] [Indexed: 11/16/2022] Open
Abstract
The bacterial-induced hollow cylinder NiO (HCNiO) nanomaterial was utilized for the enzymeless (without GOx) detection of glucose in basic conditions. The determination of glucose in 0.05 M NaOH solution with high sensitivity was performed using cyclic voltammetry (CV) and amperometry (i-t). The fundamental electrochemical parameters were analyzed and the obtained values of diffusion coefficient (D), heterogeneous rate constant (ks), electroactive surface coverage (Г), and transfer coefficient (alpha-α) are 1.75 × 10(-6) cm²/s, 57.65 M(-1)·s(-1), 1.45 × 10(-10) mol/cm², and 0.52 respectively. The peak current of the i-t method shows two dynamic linear ranges of calibration curves 0.2 to 3.5 µM and 0.5 to 250 µM for the glucose electro-oxidation. The Ni(2+)/Ni(3+) couple with the HCNiO electrode and the electrocatalytic properties were found to be sensitive to the glucose oxidation. The green chemistry of NiO preparation from bacteria and the high catalytic ability of the oxyhydroxide (NiOOH) is the good choice for the development of a glucose sensor. The best obtained sensitivity and limit of detection (LOD) for this sensor were 3978.9 µA mM(-1)·cm(-2) and 0.9 µM, respectively.
Collapse
|
38
|
Zhao Y, Wang H, Zhang P, Sun C, Wang X, Wang X, Yang R, Wang C, Zhou L. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay. Sci Rep 2016; 6:21342. [PMID: 26884128 PMCID: PMC4756364 DOI: 10.1038/srep21342] [Citation(s) in RCA: 108] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 01/21/2016] [Indexed: 12/20/2022] Open
Abstract
The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 10(4) CFU mL(-1) or 10(5) CFU mL(-1) for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R(2)) of 0.916-0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥ 80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water.
Collapse
|
39
|
Liu YJ, Mandelis A, Guo X. An absolute calibration method of an ethyl alcohol biosensor based on wavelength-modulated differential photothermal radiometry. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:115003. [PMID: 26628164 DOI: 10.1063/1.4935308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this work, laser-based wavelength-modulated differential photothermal radiometry (WM-DPTR) is applied to develop a non-invasive in-vehicle alcohol biosensor. WM-DPTR features unprecedented ethanol-specificity and sensitivity by suppressing baseline variations through a differential measurement near the peak and baseline of the mid-infrared ethanol absorption spectrum. Biosensor signal calibration curves are obtained from WM-DPTR theory and from measurements in human blood serum and ethanol solutions diffused from skin. The results demonstrate that the WM-DPTR-based calibrated alcohol biosensor can achieve high precision and accuracy for the ethanol concentration range of 0-100 mg/dl. The high-performance alcohol biosensor can be incorporated into ignition interlocks that could be fitted as a universal accessory in vehicles in an effort to reduce incidents of drinking and driving.
Collapse
|
40
|
Coelho C, Branco R, Natal-da-Luz T, Sousa JP, Morais PV. Evaluation of bacterial biosensors to determine chromate bioavailability and to assess ecotoxicity of soils. CHEMOSPHERE 2015; 128:62-69. [PMID: 25655820 DOI: 10.1016/j.chemosphere.2014.12.026] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Revised: 11/07/2014] [Accepted: 12/08/2014] [Indexed: 06/04/2023]
Abstract
Chromate can be considered a potent environmental contaminant and consequently, an understanding of chromate availability and toxicity to soil biology is essential for effective ecological assessment of metal impact in soils. This study shows the response of two bacterial bioreporters, pCHRGFP1 Escherichiacoli and pCHRGFP2 Ochrobactrumtritici, to increasing concentrations of chromate in two different soils. The bioreporters, carrying the regulatory gene chrB transcriptionally fused to the gfp reporter system, exhibited different features. In both, the fluorescence signal and the chromate concentration could be linearly correlated but E. coli biosensor functioned within the range of 0.5-2 μM and O. tritici biosensor within 2-10 μM chromate. The bioreporters were validated through comparative measurements using the chemical chromate methods of diphenylcarbazide and ionic chromatography. The bacterial sensors were used for the estimation of bioavailable fraction of chromate in a natural soil and OECD artificial soil, both spiked with chromate in increasing concentrations of 0-120 mg Cr(VI) kg(-1) of soil. OECD soil showed a faster chromate decrease comparing to the natural soil. The toxicity of soils amended with chromate was also evaluated by ecotoxicological tests through collembolan reproduction tests using Folsomia candida as test organism. Significant correlations were found between collembolans reproduction and chromate concentration in soil (lower at high chromate concentrations) measured by biosensors. Data obtained showed that the biosensors tested are sensitive to chromate presence in soil and may constitute a rapid and efficient method to measure chromate availability in soils.
Collapse
|
41
|
Olcer Z, Esen E, Muhammad T, Ersoy A, Budak S, Uludag Y. Fast and sensitive detection of mycotoxins in wheat using microfluidics based Real-time Electrochemical Profiling. Biosens Bioelectron 2014; 62:163-9. [PMID: 24998314 DOI: 10.1016/j.bios.2014.06.025] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2014] [Revised: 06/03/2014] [Accepted: 06/10/2014] [Indexed: 11/17/2022]
Abstract
The objective of the study has been the development of a new sensing platform, called Real-time Electrochemical Profiling (REP) that relies on real-time electrochemical immunoassay detection. The proposed REP platform consists of new electrode arrays that are easy to fabricate, has a small imprint allowing microfluidic system integration, enables multiplexed amperometric measurements and performs well in terms of electrochemical immunoassay detection as shown through the deoxynivalenol detection assays. The deoxynivalenol detection has been conducted according to an optimised REP assay protocol using deoxynivalenol standards at varying concentrations and a standard curve was obtained (y=-20.33ln(x)+124.06; R(2)=0.97) with a limit of detection of 6.25 ng/ml. As both ELISA and REP detection methods use horse radish peroxidase as the label and 3.3',5.5'-Tetramethylbenzidine as the substrate, the performance of the REP platform as an ELISA reader has also been investigated and a perfect correlation between the deoxynivalenol concentration and the current response was obtained (y=-14.56ln(x)+101.02; R(2)=0.99). The calibration curves of both assays have been compared to conventional ELISA tests for confirmation. After assay optimisation using toxin spiked buffer, the deoxynivalenol detection assay has also been performed to detect toxins in wheat grain.
Collapse
|
42
|
Abstract
Measurement of intracellular pH can be readily accomplished using tools and methods described in this chapter. We present a discussion of technical considerations of various ratiometric pH-sensitive probes including dyes and genetically encoded sensors. These probes can be used to measure pH across physical scales from macroscopic whole-mount tissues down to organelles and subcellular domains. We describe protocols for loading pH-sensitive probes into single cells or tissues and discuss ratiometric image acquisition and analysis.
Collapse
|
43
|
Abraham AA, Fei R, Coté GL, Grunlan MA. Self-cleaning membrane to extend the lifetime of an implanted glucose biosensor. ACS APPLIED MATERIALS & INTERFACES 2013; 5:12832-8. [PMID: 24304009 PMCID: PMC3927323 DOI: 10.1021/am4040653] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The lifetime and efficacy of a subcutaneously implanted glucose biosensor could be greatly improved by a self-cleaning membrane capable of periodic physical removal of adhered cells associated with the foreign body reaction. Previously, we reported a thermoresponsive double network nanocomposite (DNNC) membrane composed of poly(N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane nanoparticles. When the membrane was thermally cycled above and below its volume phase transition temperature (VPTT, ~33-35 °C), the associated deswelling and reswelling, respectively, led to in vitro cell release. Herein, this membrane design was tailored to meet the specific demands of a subcutaneously implanted glucose biosensor, and critical functional properties were assessed. First, N-vinylpyrrolidone (NVP) comonomer increased the VPTT to ~38 °C so that the membrane would be swollen and thus more permeable to glucose in the "off-state" (i.e., no heating) while residing in the subcutaneous tissue (~35 °C). Second, glucose diffusion kinetics though the DNNC membrane was experimentally measured in its deswollen and reswollen states. A cylindrical DNNC membrane with dimensions considered suitable for implantation (1.5 × 5 mm, diameter × length) was used to model the glucose diffusion lag time. In addition, the DNNC cylinder was used to observe dimensional changes associated with deswelling and reswelling. Noncytotoxicity was confirmed and self-cleaning was assessed in vitro in terms of thermally driven cell release to confirm the potential of the DNNC membrane to control biofouling.
Collapse
|
44
|
Couture M, Liang Y, Poirier Richard HP, Faid R, Peng W, Masson JF. Tuning the 3D plasmon field of nanohole arrays. NANOSCALE 2013; 5:12399-12408. [PMID: 24162773 DOI: 10.1039/c3nr04002j] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Modern photonics is being revolutionized through the use of nanostructured plasmonic materials, which confine light to sub-diffraction limit resolution providing universal, sensitive, and simple transducers for molecular sensors. Understanding the mechanisms by which light interacts with plasmonic crystals is essential for developing application-focussed devices. The strong influence of grating coupling on electromagnetic field distribution, frequency and degeneracy of plasmon bands has now been characterized using hexagonal nanohole arrays. An equation for nanohole arrays was derived to demonstrate the strong influence of incidence and rotation angle on optical properties of 2D plasmonic crystals such as nanohole arrays. Consequently, we report experimental data that are in strong agreement with finite difference time-domain (FDTD) simulations that clearly demonstrate the influence of the grating coupling conditions on the optical properties (such as plasmon degeneracy and bandwidth), and on the distribution of the plasmon field around nanohole arrays (including tuneable penetration depths and highly localized fields). The tuneable 3D plasmon field allowed for controlled sensing properties and by increasing the angle of incidence to 30 degrees, the resonance wavelength was tuned from 1000 to 600 nm, and the sensitivity was enhanced by nearly 300% for a protein assay using surface plasmon resonance (SPR) and by 40% with surface-enhanced Raman scattering (SERS) sensors.
Collapse
|
45
|
de Araújo Júnior JM, de Menezes Júnior JMP, de Albuquerque AAM, Almeida ODM, de Araújo FMU. Assessment and certification of neonatal incubator sensors through an inferential neural network. SENSORS 2013; 13:15613-32. [PMID: 24248278 PMCID: PMC3871086 DOI: 10.3390/s131115613] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 10/12/2013] [Accepted: 10/12/2013] [Indexed: 12/05/2022]
Abstract
Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal.
Collapse
|
46
|
Dungan K, Graessle K, Sagrilla C. The effect of congestive heart failure on sensor accuracy among hospitalized patients with type 2 diabetes. Diabetes Technol Ther 2013; 15:817-24. [PMID: 24050738 PMCID: PMC3781123 DOI: 10.1089/dia.2013.0094] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Congestive heart failure (CHF) features disturbances in the interstitial environment that may affect the accuracy of subcutaneous continuous glucose monitoring (CGM). SUBJECTS AND METHODS A pooled analysis of two studies of hospitalized patients with type 2 diabetes randomized to intravenous or subcutaneous insulin was conducted. One study enrolled patients with CHF exacerbation, whereas history of CHF was an exclusion criterion in the other. All patients wore a professional CGM device for at least 24 h. Intravenous insulin was administered according to the institution's nursing-run protocol (duration of 12 and 48 h in non-CHF and CHF protocols, respectively). Subcutaneous insulin was delivered similarly in both groups. RESULTS Subjects with CHF (n=43) had higher admission glucose and hemoglobin A1c compared with non-CHF subjects (n=32), but the sensor glucose values were similar. Overall mean absolute relative difference (MARD) was similar between CHF and non-CHF subjects (0.11 vs. 0.08, respectively; P=0.12). MARD was higher in the 100-149 mg/dL (P=0.003) and >199 mg/dL (P = 0.02) strata among CHF subjects. Static glucose and continuous glucose error grid analyses favored the non-CHF group. In multivariable analyses, only glucose coefficient of variation and log sensor time were independent predictors of elevated overall MARD >0.10. After adjustment for other factors, only increasing log sensor time was a significant predictor of elevated MARD in the 100-149 mg/dL strata. CONCLUSIONS Among hospitalized subjects with type 2 diabetes, CHF exacerbation is not associated with lower sensor accuracy after adjustment for other factors, but this requires confirmation over a wider glucose range.
Collapse
|
47
|
Obermaier K, Schmelzeisen-Redeker G, Schoemaker M, Klötzer HM, Kirchsteiger H, Eikmeier H, del Re L. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment. J Diabetes Sci Technol 2013; 7:824-32. [PMID: 23911163 PMCID: PMC3879746 DOI: 10.1177/193229681300700404] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. MATERIALS AND METHODS Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. RESULTS The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. CONCLUSIONS Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and presented separately for clinically different categories, e.g., hypoglycemia, exercise, or night and day.
Collapse
|
48
|
Mensh BD, Wisniewski NA, Neil BM, Burnett DR. Susceptibility of interstitial continuous glucose monitor performance to sleeping position. J Diabetes Sci Technol 2013; 7:863-70. [PMID: 23911167 PMCID: PMC3879750 DOI: 10.1177/193229681300700408] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Developing a round-the-clock artificial pancreas requires accurate and stable continuous glucose monitoring. The most widely used continuous glucose monitors (CGMs) are percutaneous, with the sensor residing in the interstitial space. Inaccuracies in percutaneous CGM readings during periods of lying on the devices (e.g., in various sleeping positions) have been anecdotally reported but not systematically studied. METHODS In order to assess the impact of sleep and sleep position on CGM performance, we conducted a study in human subjects in which we measured the variability of interstitial CGM data at night as a function of sleeping position. Commercially available sensors were placed for 4 days in the abdominal subcutaneous tissue in healthy, nondiabetic volunteers (four sensors per person, two per side). Nocturnal sleeping position was determined from video recordings and correlated to sensor data. RESULTS We observed that, although the median of the four sensor readings was typically 70-110 mg/dl during sleep, individual sensors intermittently exhibited aberrant glucose readings (>25 mg/dl away from median) and that these aberrant readings were strongly correlated with subjects lying on the sensors. We expected and observed that most of these aberrant sleep-position-related CGM readings were sudden decreases in reported glucose values, presumably due to local blood-flow decreases caused by tissue compression. Curiously, in rare cases, the aberrant CGM readings were elevated values. CONCLUSIONS These findings highlight limitations in our understanding of interstitial fluid physiology in the subcutaneous space and have significant implications for the utilization of sensors in the construction of an artificial pancreas.
Collapse
|
49
|
Freckmann G, Pleus S, Link M, Zschornack E, Klötzer HM, Haug C. Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel. J Diabetes Sci Technol 2013; 7:842-53. [PMID: 23911165 PMCID: PMC3879748 DOI: 10.1177/193229681300700406] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND This study is aimed at comparing the performance of three continuous glucose monitoring (CGM) systems following the Clinical and Laboratory Standards Institute's POCT05-A guideline, which provides recommendations for performance evaluation of CGM systems. METHODS A total of 12 subjects with type 1 diabetes were enrolled in this study. Each subject wore six CGM systems in parallel, two sensors of each CGM system [FreeStyle Navigator™ (Navigator), MiniMed Guardian® REAL-Time with Enlite sensor (Guardian), DexCom™ Seven® Plus 3rd generation (Seven Plus)]. Each sensor was used for the lifetime specified by the manufacturer. To follow POCT05-A recommendations, glucose excursions were induced on two separate occasions, and venous and capillary blood glucose (BG) concentrations were obtained every 15 min for five consecutive hours. Capillary BG concentrations were measured at least once per hour during the day and once at night. Parameters investigated were CGM-to-BG differences [mean absolute relative difference (MARD)] and sensor-to-sensor differences [precision absolute relative difference (PARD)]. RESULTS Compared with capillary BG reference readings, the Navigator showed the lowest MARD, with 12.1% overall and 24.6% in the hypoglycemic range; for the Guardian and the Seven Plus, MARD was 16.2%/34.9% and 16.3%/32.7%, respectively. PARD also was lowest for the Navigator (9.6%/9.8%), followed by the Seven Plus (16.7%/25.5%) and the Guardian (18.1%/20.2%). During induced glucose excursions, MARD between CGM and BG was, again, lowest for the Navigator (14.3%), followed by the Seven Plus (15.8%) and the Guardian (19.2%). CONCLUSIONS In this study, two sensors of each of the three CGM systems were compared in a setting following POCT05-A recommendations. The Navigator CGM system achieved more accurate results than the Guardian or the Seven Plus with respect to MARD and PARD. Performance in the hypoglycemic range was markedly worse for all CGM systems when compared with BG results.
Collapse
|
50
|
Arya SK, Pui TS, Wong CC, Kumar S, Rahman ARA. Effects of the electrode size and modification protocol on a label-free electrochemical biosensor. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:6770-6777. [PMID: 23651210 DOI: 10.1021/la401109r] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In the present work, the effect of a surface modification protocol along with the electrode size has been investigated for developing an efficient, label-free electrochemical biosensing method for diagnosis of traumatic brain injury (TBI) biomarkers. A microdisk electrode array (MDEA) and a macroelectrode with a comb structure (MECS) were modified with an anti-GFAP (GFAP = glial fibrillary acidic protein) antibody using two protocols for optimum and label-free detection of GFAP, a promising acute-phase TBI biomarker. For the MDEA, an array of six microdisks with a 100 μm diameter and, for the MECS, a 3.2 mm × 5.5 mm electrode 5 μm wide with 10 μm spaced comb fingers were modified using an optimized protocol for dithiobis(succinimidyl propionate) (DSP) self-assembled monolayer formation. Anti-GFAP was covalently bound, and the remaining free DSP groups were blocked using ethanolamine (Ea). Sensors were exposed to solutions with different GFAP concentrations, and a label-free electrochemical impedance spectroscopy (EIS) technique was used to determine the concentration. EIS results confirmed that both types of Ea/anti-GFAP/DSP/Au electrodes modified with an optimized DSP-based protocol can accurately detect GFAP in the range of 1 pg mL(-1) to 100 ng mL(-1) with a detection limit of 1 pg mL(-1). However, the cross-use of the MDEA protocol on the MECS and vice versa resulted in very low sensitivity or poor signal resolution, underscoring the importance of proper matching of the electrode size and type and the surface modification protocol.
Collapse
|