26
|
Tironi F, Azzola F, Barbaro B, Corbella S, Taschieri S, Savadori P, Francetti LA. CAD/CAM Titanium Meshes for GBR: A Case Series with Preliminary Histologic Analysis. INT J PERIODONT REST 2024; 44:1-12. [PMID: 38787705 DOI: 10.11607/prd.6558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
Titanium has been proposed as a mesh material for guided bone regeneration (GBR) since the 1990s. To overcome difficulties in shaping and adapting meshes to the defect, digital techniques were introduced to digitally print meshes capable of fitting the bone perfectly, reproduced through the patient's CT scan. Five patients were included in this case series, and their CBCT data were acquired and sent to the producer of the titanium meshes. 3D regenerative surgery was performed with titanium meshes and a mix of demineralized bovine bone matrix (DBBM) and autogenous bone (1:1 ratio). Radiographic measures were evaluated on paraxial sections of the CBCT through a dedicated software. When possible, regenerated bone samples were obtained at implant insertion. Four out of five regenerated areas healed without local or systemic complications. One mesh was removed after 2 months and 2 weeks due to exposure. The mean vertical bone gain was 4.3 ± 1.5 mm (range: 2.5 to 7 mm). Two histologic samples were obtained. In sample 1, bone tissue area and graft material area were 44.4% and 12.5%, respectively; in sample 2, the same parameters were 15.6% and 16.9%, respectively.
Collapse
|
27
|
Perez A, Martinelli-Klay CP, Lombardi T. Increased Peri-implant Bone Formation Around Simultaneously Grafted Hydrophilic Microrough Titanium Implants: An Exploratory Human Histometric Analysis in Four Patients. INT J PERIODONT REST 2024; 44:1-11. [PMID: 38787707 DOI: 10.11607/prd.6562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/09/2023]
Abstract
This pilot case series histologically and histometrically investigated the influence of implant surface hydrophilicity on early osseointegration and peri-implant bone formation around simultaneously grafted immediate implants. Hydrophilic test (SLAactive) or hydrophobic control (SLA) implants were immediately placed in maxillary molar extraction sites and simultaneously grafted with mineralized cancellous bone allograft (MCBA). Core biopsy samples were obtained at 3 weeks postplacement and histometrically compared for bone-to-implant contact, quantity of graft material, new bone formation, tissue reaction, and inflammatory scores. Test implants showed a more pronounced implant-bone apposition, peri-implant bone formation, and bone aggregate than control implants. Trabecular bone formation and maturation were also qualitatively advanced around test implants. These results indicate that the combination of implant surface and bone graft may affect periimplant bone formation.
Collapse
|
28
|
Giudice A, Attanasio F, Bennardo F, Antonelli A, Vercellotti T. Usefulness of Wedge-Shaped Implants in the Full-Arch Rehabilitation of Severe Maxillary Atrophy: A Case Report. INT J PERIODONT REST 2024; 44:1-9. [PMID: 38787710 DOI: 10.11607/prd.6453] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
The management of marked horizontal bone atrophy represents a critical challenge for traditional implantology procedures. For this purpose, clinicians have developed several protocols and procedures to allow the most suitable and accurate surgical and prosthetic implant rehabilitation. Despite the development of guided bone regeneration methods and the use of small-diameter implants, the rehabilitation of thin bone areas is a clinical dilemma for the medium- and long-term survival of implant-prosthetic therapies. This clinical case evaluates the use of wedge-shaped implants for the full-arch rehabilitation of an atrophic maxilla with a thin ridge. This treatment choice allowed a minimally invasive rehabilitation, avoiding regenerative bone surgery, while respecting biologic and prosthetic limits. Furthermore, evaluation of the implant stability quotient and marginal bone loss values during the first year of follow-up allowed analysis of the behavior of this rehabilitation in fullarch maxillary cases.
Collapse
|
29
|
Yang M, Ma Y, Han W, Qu Z. The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation. PLoS One 2024; 19:e0304091. [PMID: 38781146 PMCID: PMC11115217 DOI: 10.1371/journal.pone.0304091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 05/06/2024] [Indexed: 05/25/2024] Open
Abstract
OBJECTIVE To date, it remains a challenge to conduct maxillary sinus floor elevation (MSFE) owing to heterogeneity of anatomical structures and limited operative visibility of the maxillary sinus. The aim of this study is to investigate the safety of MSFE and the accuracy of implant placement using dynamic navigation. METHODS Forty-two implants were placed in thirty-five patients requiring implantation in posterior maxilla with dynamic navigation. They were assigned to either lateral window sinus floor elevation (LWSFE) group (n = 22) or transcrestal sinus floor elevation (TSFE) group (n = 20) according to the residual alveolar bone height (RBH). Platform deviation, apex deviation and angular deviation between actual and planned implant placement were measured in precision evaluation software. Three deviations of two groups were compared via SPSS 22.0 software. RESULTS Neither accidental bleeding nor perforation of Schneiderian membrane occurred in any patients. The actual window position of LWSFE was consistent with the preoperative design. There were no significant differences in platform, apex and angular deviations between the two groups (P > 0.05). CONCLUSION In this study the dynamic navigation harvested clinically acceptable safety of MSFE and accuracy for implant placement in posterior maxillary region. The dynamic navigation would provide the clinician with assistance in achieving precise preoperative planning and reducing complications in surgical procedures. The granular bone grafts used in the LWSFE did not significantly affection on the accuracy of the simultaneous implant placement under the guidance of dynamic navigation.
Collapse
|
30
|
Lee J, Lim YJ, Ahn JS, Kim B, Baek YW, Lim BS. Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study. PLoS One 2024; 19:e0290595. [PMID: 38776308 PMCID: PMC11111012 DOI: 10.1371/journal.pone.0290595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 12/27/2023] [Indexed: 05/24/2024] Open
Abstract
Non-invasive objective implant stability measurements are needed to determine the appropriate timing of prosthetic fitting after implant placement. We compared the early implant stability results obtained using resonance frequency analysis (RFA) and damping capacity analysis (DCA) depending on the implant length and bone density. Total 60, 4.0 mm diameter implants of various lengths (7.3 mm, 10 mm, and 13 mm) were used. In Group I, low-density bone was described using 15 PCF (0.24 g/cm3) polyurethane bone blocks, and in Group II, 30 PCF (0.48 g/cm3) polyurethane bone blocks were used to describe medium density bone. RFA was performed using an Osstell® Beacon+; DCA was performed using Anycheck®. Measurements were repeated five times for each implant. Statistical significance was set at P <0.05. In Group I, bone density and primary implant stability were positively correlated, while implant length and primary implant stability were positively correlated. In Group II, the implant stability quotient (ISQ) and implant stability test (IST) values in did not change significantly above a certain length. Primary implant stability was positively correlated with bone density and improved with increasing implant length at low bone densities. Compared with the Osstell® Beacon+, the simplicity of Anycheck® was easy to use and accessible.
Collapse
|
31
|
Nagata K, Okubo M, Saito K, Nakashizu T, Atsumi M, Kawana H. Verification of the accuracy of dynamic navigation for conventional and mouthpiece methods: in vivo study. BMC Oral Health 2024; 24:596. [PMID: 38778269 PMCID: PMC11112779 DOI: 10.1186/s12903-024-04327-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 05/03/2024] [Indexed: 05/25/2024] Open
Abstract
BACKGROUND Dynamic navigation for implant placement is becoming popular under the concept of top-down treatment. The purpose of this study is to verify the accuracy of a dynamic navigation system for implant placement. METHODS Implant placement was performed on 38 patients using 50 implant fixtures. Patients in group C were treated using a conventional method, in which thermoplastic clips were fixed to the teeth, and patients in group M were treated using thermoplastic clips fixed to a mouthpiece attached to the teeth. The groups were compared to verify whether an accuracy difference existed. A treatment planning support program for dental implants was used to superimpose the postoperative computed tomography data on the preoperative implant design data to measure the entry point, apex point, and angular deviation. RESULTS The accuracy of group C was 1.36 ± 0.51 mm for entry point, 1.30 ± 0.59 mm for apex point, and 3.20 ± 0.74° for angular deviation. The accuracy of group M was 1.06 ± 0.31 mm for the entry point, 1.02 ± 0.30 mm for the apex point, and 2.91 ± 0.97° for angular deviation. Significant differences were observed in the entry and apex points between the two groups. CONCLUSIONS The results indicate that group M exhibited better accuracy than group C, indicating that the stability of the thermoplastic clip is important for ensuring the accuracy of the dynamic navigation system. No previous studies have verified the accuracy of this system using the mouthpiece method, and additional data is required to confirm its accuracy for dental implant placement. The mouthpiece method improves the accuracy of implant placement and provides a safer implant treatment than the conventional method. TRIAL REGISTRATION University hospital Medical Information Network Clinical Trials Registry (UMIN-CTR), Registration Number: UMIN000051949, URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view_his.cgi on August 21, 2023.
Collapse
|
32
|
Wang SH, Fuh LJ, Chen MYC, Tsai MT, Huang HL, Peng SL, Hsu JT. Preoperative assessment of bone density for dental implantation: a comparative study of three different ROI methods. Head Face Med 2024; 20:33. [PMID: 38760840 PMCID: PMC11100211 DOI: 10.1186/s13005-024-00434-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 05/10/2024] [Indexed: 05/19/2024] Open
Abstract
BACKGROUND Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.
Collapse
|
33
|
Solderer A, Hicklin SP, Aßenmacher M, Ender A, Schmidlin PR. Influence of an allogenic collagen scaffold on implant sites with thin supracrestal tissue height: a randomized clinical trial. Clin Oral Investig 2024; 28:313. [PMID: 38748295 PMCID: PMC11096242 DOI: 10.1007/s00784-024-05716-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Accepted: 05/08/2024] [Indexed: 05/18/2024]
Abstract
OBJECTIVES This randomized clinical trial focused on patients with thin peri-implant soft-tissue height (STH) (≤ 2.5 mm) and investigated the impact of an allogenic collagen scaffold (aCS) on supracrestal tissue height and marginal bone loss (MBL). MATERIAL & METHODS Forty patients received bone level implants and were randomly assigned to the test group with simultaneous tissue thickening with aCS or the control group. After three months, prosthetic restoration occurred. STH measurements were taken at baseline (T0) and reopening surgery (TR), with MBL assessed at 12 months (T1). Descriptive statistics were calculated for continuous variables, and counts for categorical variables (significance level, p = 0.05). RESULTS At T1, 37 patients were available. At T0, control and test groups had mean STH values of 2.3 ± 0.3 mm and 2.1 ± 0.4 mm. TR revealed mean STH values of 2.3 ± 0.2 mm (control) and 2.6 ± 0.7 mm (test), with a significant tissue thickening of 0.5 ± 0.6 mm in the test group (p < 0.03). At T1, control and test groups showed MBL mean values of 1.1 ± 0.8 mm and 1.0 ± 0.6 mm, with a moderate but significant correlation with STH thickening (-0.34), implant position (0.43), history of periodontitis (0.39), and smoking status (0.27). CONCLUSION The use of an aCS protocol resulted in soft tissue thickening but did not reach a threshold to reliably reduce MBL compared to the control group within the study's limitations. CLINICAL RELEVANCE Peri-implant STH is crucial for maintaining peri-implant marginal bone stability. Marginal bone stability represents a crucial factor in prevention of peri-implantitis development. German register of clinical trial registration number DRKS00033290.
Collapse
|
34
|
Younis H, Lv C, Xu B, Zhou H, Du L, Liao L, Zhao N, Long W, Elayah SA, Chang X, He L. Accuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study. Head Face Med 2024; 20:30. [PMID: 38745297 PMCID: PMC11092008 DOI: 10.1186/s13005-024-00433-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 04/29/2024] [Indexed: 05/16/2024] Open
Abstract
BACKGROUND Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique's advantages and disadvantages. MATERIALS AND METHODS Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. RESULTS The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). CONCLUSION Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. TRIAL REGISTRATION This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.
Collapse
|
35
|
Wu Q, Lou Y, Sun J, Xie C, Wu J, Yu H. Accuracy of the novel digital non-cross-arch surgical guides with integration of tooth undercut retention and screw-bone support for implant placement in mandibular free-end. BMC Oral Health 2024; 24:550. [PMID: 38734597 PMCID: PMC11088151 DOI: 10.1186/s12903-024-04329-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 05/03/2024] [Indexed: 05/13/2024] Open
Abstract
BACKGROUND Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.
Collapse
|
36
|
Wang YL, Zhang YF. [Effects and techniques of soft tissue augmentation in immediate implant treatment]. ZHONGHUA KOU QIANG YI XUE ZA ZHI = ZHONGHUA KOUQIANG YIXUE ZAZHI = CHINESE JOURNAL OF STOMATOLOGY 2024; 59:517-522. [PMID: 38637008 DOI: 10.3760/cma.j.cn112144-20240227-00090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Immediate implant placement can reduce the number of treatments and the time without teeth, but it carries a higher aesthetic risk. Soft tissue augmentation can reduce the risk of gingival recession to a certain extent, improve the predictability and long-term stability of immediate implant aesthetics, and is currently a hot research topic. A comprehensive understanding of the evidence-based medicine and surgical techniques using soft tissue augmentation in immediate implant surgery can assist in clinical diagnosis, treatment decisions and improve treatment outcomes. This article elucidates the changes in soft and hard tissues after immediate implant placement, aesthetic risks, and risk factors. It also discusses the advantages, timing, material selection, and commonly used clinical techniques of soft tissue transplantation in immediate implantation, aiming to provide reference for clinical doctors to improve the effectiveness of immediate implantation.
Collapse
|
37
|
Ruppin JM, Stimmelmayr M. High insertion torque versus regular insertion torque: early crestal bone changes on dental implants in relation to primary stability-a retrospective clinical study. Int J Implant Dent 2024; 10:22. [PMID: 38700739 PMCID: PMC11068710 DOI: 10.1186/s40729-024-00540-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 04/23/2024] [Indexed: 05/06/2024] Open
Abstract
The aim of the presented retrospective study was to evaluate the early crestal bone changes around an implant type designed for high primary stability. A total number of 111 implants placed clinically were evaluated regarding insertion torque, bone density, implant stability quotient (ISQ) and early crestal bone loss from standardized digital radiographs. The implants were allocated in two groups: the "regular torque " group contained all implants that achieved less than 50 Ncm as final insertion torque (n = 63) and the "high torque" group contained the implants that achieved 50-80 Ncm (n = 48). To avoid possible damage either to the implant´s inner connection or to the bone by application of excessive force, a limit of 80 Ncm was set for all surgeries. All implants underwent submerged healing for three months. ISQ measurements and standardized digital radiographs were taken at day of insertion and at day of second stage surgery. The bone loss was measured on the mesial and distal aspect of the implant. The data evaluation showed the following results: Mean bone loss was 0.27 ± 0.30 mm for the high torque group and 0.24 ± 0.27 mm for the regular torque group. The difference was not statistically significant (p = 0.552). In the two groups, no complications nor implant loss occurred. For the evaluated implant type, there was no significant difference in crestal bone changes and complication rate between high and regular insertion torque in the early healing period.
Collapse
|
38
|
Won C. Restoring Severely Atrophic Edentulous Ridge of Mandible Using Self-Expanding Tissue Expander-A Case Report. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:759. [PMID: 38792943 PMCID: PMC11123316 DOI: 10.3390/medicina60050759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2024] [Revised: 04/20/2024] [Accepted: 04/30/2024] [Indexed: 05/26/2024]
Abstract
This report describes the use of Self Inflating Tissue Expanders (SITEs) to rehabilitate severely atrophic edentulous mandibular ridges, enabling successful bone grafting and implant placement. The treatment resulted in stable and complication-free implants over a seven-year follow-up, demonstrating SITEs' effectiveness in providing sufficient bone volume and soft tissue coverage for dental implants.
Collapse
|
39
|
Liang L, Wu X, Yan Q, Shi B. Are short implants (≤8.5 mm) reliable in the rehabilitation of completely edentulous patients: A systematic review and meta-analysis. J Prosthet Dent 2024; 131:826-832. [PMID: 35469646 DOI: 10.1016/j.prosdent.2022.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 02/16/2022] [Accepted: 02/16/2022] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM Limited data are available regarding the reliability of short implants (≤8.5 mm) in patients with resorbed completely edentulous jaws. PURPOSE The purpose of this systematic review and meta-analysis was to compare the clinical outcomes of short implants (intervention) versus long implants (≥10 mm, comparison) in the rehabilitation of completely edentulous jaws. MATERIAL AND METHODS The PubMed, Embase, and Cochrane CENTRAL databases were searched for randomized controlled trials (RCTs) comparing short and long implants supporting fixed or removable prostheses in completely edentulous jaws. Outcome measures included implant survival, marginal bone loss (MBL), and biological and technical complications. The risks of bias within and across the studies were assessed, and meta-analyses, sensitivity analyses, and subgroup analyses by types of prostheses, jaw locations, and follow-up length were performed. RESULTS A total of 4 RCTs with 158 participants were included. No significant difference was found between short implants and long implants regarding implant survival (RR=1.01, 95% CI: 0.97 to 1.05, P=.710, I2=70%) or MBL (MD=-0.19 mm, 95% CI: -0.39 to 0.02, P=.070, I2=94%). In subgroup analyses, when supporting fixed prostheses, short implants showed significantly less MBL than long implants (P<.001). In the mandible, short implants showed higher implant survival (P=.008) and less MBL (P<.001). Participants receiving long implants combined with bone augmentation procedures reported more postsurgery pain. CONCLUSIONS For completely edentulous jaws, short implants provide a reliable treatment alternative, as survival and MBL were not different when compared with those of long implants. However, additional high-level evidence is still needed to determine the long-term clinical outcomes of short implants in completely edentulous jaws.
Collapse
|
40
|
Schönegg D, Essig H, Al-Haj Husain A, Weber FE, Valdec S. Patient-specific beta-tricalcium phosphate scaffold for customized alveolar ridge augmentation: a case report : Case Report: patient-specific β-TCP scaffold for alveolar ridge CBR. Int J Implant Dent 2024; 10:21. [PMID: 38691252 PMCID: PMC11063008 DOI: 10.1186/s40729-024-00541-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Accepted: 04/23/2024] [Indexed: 05/03/2024] Open
Abstract
BACKGROUND Beta-tricalcium phosphate (β-TCP) is a biocompatible ceramic material widely used in the field of oral regeneration. Due to its excellent biological and mechanical properties, it is increasingly utilized for alveolar ridge augmentation or guided bone regeneration (GBR). With recent advances in computer-aided design and manufacturing (CAD/CAM), β-TCP can now be used in the form of digitally designed patient-specific scaffolds for customized bone regeneration (CBR) of advanced defects in a two-stage implant therapy concept. In this case report following the CARE case report guidelines, we present a novel application of a patient-specific β-TCP scaffold in pre-implant mandibular alveolar ridge augmentation. CASE PRESENTATION A 63-year-old female patient with significant horizontal bone loss in the posterior mandible was treated with a custom β-TCP scaffold in the context of a two-stage backward-planned implant therapy. Cone-beam computed tomography nine months after augmentation showed successful integration of the scaffold into the surrounding bone, allowing implant placement. Follow-up until two years after initial surgery showed excellent oral and peri-implant health. CONCLUSIONS This case highlights the potential of patient-specific β-TCP scaffolds for alveolar ridge augmentation and their advantage over traditional techniques, including avoidance of xeno-, allo-, and autografts. The results provide encouraging evidence for their use in clinical practice. Patient-specific β-TCP scaffolds may be a promising alternative for clinicians seeking to provide their patients with safe, predictable, and effective alveolar ridge augmentation results in customized bone regeneration procedures.
Collapse
|
41
|
Zhang L, Zhou C, Jiang J, Chen X, Wang Y, Xu A, He F. Clinical outcomes and risk factor analysis of dental implants inserted with lateral maxillary sinus floor augmentation: A 3- to 8-year retrospective study. J Clin Periodontol 2024; 51:652-664. [PMID: 38246602 DOI: 10.1111/jcpe.13947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 12/11/2023] [Accepted: 01/05/2024] [Indexed: 01/23/2024]
Abstract
AIM To evaluate the 3- to 8-year outcomes of dental implants placed with lateral sinus floor augmentation (LSFA) and to identify factors affecting implant survival. MATERIALS AND METHODS This retrospective study was performed by screening all implants placed with LSFA procedures, which were conducted between January 2012 and December 2016. Subantral bone gain (SABG) and apical bone height (ABH) were assessed using panoramic radiographs. The cumulative survival rate of implants was analysed using life-table analysis and Kaplan-Meier survival curves. The influential risk factors affecting survival were assessed using univariate log-rank tests and multivariable mixture cure rate model. Implant complications were recorded. RESULTS Based on the established criteria, a total of 449 patients (760 implants) were included in this study. In the 3- to 8-year follow-up (mean ± SD, 5.81 ± 1.33 years), 15 implants in 14 patients failed, with a CRS of 96.81% on an implant basis and 95.07% on a patient basis. A history of periodontitis and poor compliance with supportive periodontal treatment was associated with a significantly higher risk of implant failure at both implant and patient levels. Significant decreases in ABH occurred during each yearly interval except for 3 years. A similar trend has been observed for SABG at 1, 2, 6 and 8 years. The total complication rate was 31.84% on implant basis, with peri-implant mucositis (21.58%) being the most frequent biologic complication and porcelain cracking (5.00%) being the most common technical complication. CONCLUSIONS Implant with LSFA is a reliable treatment option in atrophic maxilla. A history of periodontitis without regular supportive periodontal treatment was identified as a predictor for implant failure. Slight but significant shrinkage of vertically augmented bone can be observed after implant placement.
Collapse
|
42
|
Block MS. REPLY: Transitioning From Teeth to Implants: A Narrative Review. J Oral Maxillofac Surg 2024; 82:516. [PMID: 38697690 DOI: 10.1016/j.joms.2024.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 01/31/2024] [Indexed: 05/05/2024]
|
43
|
Mozer PS, Guentsch A. An in vitro analysis of the accuracy of static and robot-assisted implant surgery. Clin Oral Implants Res 2024; 35:487-497. [PMID: 38189471 DOI: 10.1111/clr.14233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 11/26/2023] [Accepted: 12/19/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVES Robot-assisted implant surgery (RAIS) is purported to improve the accuracy of implant placement. The objective of this study was to compare RAIS with static computer-assisted implant surgery (sCAIS) in a controlled environment. MATERIALS AND METHODS A total of n = 102 implants were placed in the same modified typodont (n = 17 repeated simulated implant surgeries with each n = 3 implants per group) using robot-assisted or static computer-assisted implant surgery. The final implant positions were digitized utilizing cone-beam tomography and compared with the planned position. The angular deviation was the primary outcome parameter. 3D deviations at the implant platform level and the apex were secondary outcome parameters. Accuracy in terms of trueness and precision were assessed. Means, standard deviation, and 95%-confidence intervals were analyzed statistically. RESULTS The overall angular deviation was 2.66 ± 1.83° for the robotic system and 0.68 ± 0.38° for guided surgery using static guides (p < .001), the 3D-deviation of the implant platform at crest level was for sCAIS 0.79 ± 0.28 mm and RAIS 1.51 ± 0.53 mm (p < .001) and at the apex for sCAIS 0.82 ± 0.26 mm and for RAIS 1.97 ± 0.79 mm (p < .001), respectively. CONCLUSIONS Robotically guided implant surgery was less accurate in terms of trueness (planned vs. actual position) and precision (deviations among implants) than traditional static computer-assisted implant surgery in this in vitro study.
Collapse
|
44
|
Chen J, Bu L, Xu G. Identifying an optimal approach for the placement of pterygoid implants: A 3D finite element analysis. J Prosthet Dent 2024; 131:917.e1-917.e13. [PMID: 38443244 DOI: 10.1016/j.prosdent.2024.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 02/14/2024] [Accepted: 02/15/2024] [Indexed: 03/07/2024]
Abstract
STATEMENT OF PROBLEM A consensus on the optimal approach to the placement of pterygoid implants is lacking. PURPOSE The purpose of this finite element analysis study was to determine the optimal approach to the placement of pterygoid implants by comparing biomechanical behavior. MATERIAL AND METHODS An edentulous and moderately atrophic maxilla with the anatomic structure of the pterygomaxillary region was constructed. Complete arch restorations with 4 standard anterior implants and pterygoid implants in 3 approaches were simulated: L70, long pterygoid implants (4.1×18 mm) inclined at 70 degrees relative to the Frankfort horizontal plane with anchorage in the pterygoid process; L45, long pterygoid implants (4.1×20 mm) inclined at 45 degrees with anchorage in the pterygoid process; and S45, shorter pterygoid implants (4.1×13 mm) inclined 45 degrees without apical anchorage. The L70, L45, and S45 groups were classified as D or S depending on the bone quality: D3 (dense trabecular bone) or D4 (sparse trabecular bone). A total of 6 finite element models were built. The bone failure theory, based on the von Mises theory, was used to judge yielding of the trabecular bone. The von Mises stress (σVM) distribution was measured in the cortical bone, the trabecular bone, and on the implant surface. Deformation (DF) distribution was obtained for the entire bone (DFB) and bone surrounding the pterygoid implant (DFP). RESULTS L70 showed a lower maximum σVM value (maxσVM), more uniform σVM distribution in the cortical bone, trabecular bone, and on the implant surface and a lower maximum DFp value (maxDFp), especially in the D4 bone. The biomechanical behaviors were similar in L45 and S45 with no stress distribution in the pterygoid process. In the D4 bone, L70, L45, and S45 exceeded the limited stress of the bone failure theory by 50%, 130%, and 130%, while all values were under the limit in D3 bone. CONCLUSIONS The approach of pterygoid implants inclined at 70 degrees relative to the Frankfort plane with anchorage in the pterygoid process was optimal, providing improved biomechanical behavior. Clinically, in the case of D4 bone, the inclined angulation of pterygoid implants should be 70 degrees to minimize the risk of failure.
Collapse
|
45
|
Liu Y, Lan D, Gao J, Deng C, Man Y. Guided bone regeneration for peri-implant augmentation: A retrospective study comparing two surgical techniques with a mean follow-up of 26 months. Clin Oral Implants Res 2024; 35:573-584. [PMID: 38467593 DOI: 10.1111/clr.14254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 01/31/2024] [Accepted: 02/24/2024] [Indexed: 03/13/2024]
Abstract
OBJECTIVES To introduce a modified guided bone regeneration (GBR) technique using intact periosteum and deproteinized bovine bone mineral (DBBM) for peri-implant augmentation and compare the clinical outcomes with those of conventional GBR. MATERIALS AND METHODS Patients who received peri-implant augmentation in posterior sites between 2015 and 2021 were reviewed in this study. Group A was treated with a modified GBR technique, and Group B was treated with conventional GBR. For group comparison, propensity score matching was performed with a sensitivity analysis. The implant survival rate, dimensional changes in hard tissue, marginal bone loss (MBL), and peri-implant parameters were evaluated. RESULTS In total, 114 implants from 98 patients were included. The implant survival rates were 95.74% in Group A and 95.00% in Group B during the follow-up period. At 6 months, the median horizontal thickness was recorded at 0.87 mm (IQ1-IQ3 = 0.00-1.75 mm) in Group A, exhibiting a relatively lower value compared to the corresponding measurement of 0.98 mm (IQ1-IQ3 = 0.00-1.89 mm) in Group B (p = .937). Vertical height displayed no statistically significant intergroup difference between the two groups (p = .758). The mean follow-up period was 25.83 ± 12.93 months after loading in Group A and 27.47 ± 21.29 months in Group B (p = .761). MBL and peri-implant parameters were comparable between the two groups. CONCLUSIONS Within the limitations of this study, the modified GBR technique using intact periosteum and DBBM grafting might be a viable alternative to correct bone defects around implants in molar and premolar sites.
Collapse
|
46
|
Gehrke P, Rashidpour M, Sader R, Weigl P. A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies. Int J Implant Dent 2024; 10:20. [PMID: 38691258 PMCID: PMC11063012 DOI: 10.1186/s40729-024-00543-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 04/23/2024] [Indexed: 05/03/2024] Open
Abstract
PURPOSE The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs). METHODS Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes. RESULTS 16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature. CONCLUSIONS The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Collapse
|
47
|
He J, Liu Y, Lin Z, Li Y, Li C, Zhou L. Feasibility of implant placement in healed mandibular molar sites: A retrospective cone beam computed tomography study. J Prosthet Dent 2024; 131:904.e1-904.e10. [PMID: 38472073 DOI: 10.1016/j.prosdent.2024.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 01/31/2024] [Accepted: 02/02/2024] [Indexed: 03/14/2024]
Abstract
STATEMENT OF PROBLEM Implant placement in the mandibular molar sites plays a crucial role in the restoration of edentulous mandibles. However, the evaluation of bone quantity before implant surgery using cone beam computed tomography (CBCT) is lacking. PURPOSE The purpose of this clinical study was to evaluate CBCT images of edentulous patients to analyze the feasibility of implant placement in healed mandibular molar sites. MATERIAL AND METHODS The CBCT data of 138 patients were analyzed in the sagittal plane for measurements of mandibular bone height (MBH), superior bone height (SBH), inferior bone height (IBH), buccal bone width (BBW), lingual bone width (LBW), and alveolar bone widths (ABWs). The edentulous sites were categorized according to the bone quantity and complexity of the implant surgery. Multivariate analysis of variance (MANOVA) was used to analyze the site, sex, and age-related variations. An independent t test was used to compare the difference of bone dimension in different sites and between sexes. One-way ANOVA followed by post hoc tests were used to analyze the difference between different age groups. Categorical variables were presented as number of events and percentages. The chi-squared test was used to compare categorical variables (α=.05). RESULTS A total of 534 sites of interest were recorded, including 274 hemimandibles. A significant difference in BBW was found between the first and second molar sites. Men had higher MBH, SBH, IBH, and BBW than women. The distribution of implant surgical complexity in the conventional group was 63.5%, while the buccolingual tilted implant group accounted for 17.0%, and the complicated group accounted for 19.5%. Of the 274 hemimandibles, an implant could be placed directly at molar sites in 88% of situations. CONCLUSIONS The BBW at the mandibular second molar site was greater than that at the first molar site. The amount of available bone in the SBH and BBW was greater in men than in women at the healed molar sites. Age did not significantly affect the complexity of the implant surgery. Implants can be placed directly in healed mandibular molar sites in most patients who require a complete arch mandibular implant-supported restoration.
Collapse
|
48
|
Lafzi A, Kadkhodazadeh M, Farahmand A, Sabet JM, Amid R, Moscowchi A. Time management in multistep periodontal and implant treatments: a practical guide. GENERAL DENTISTRY 2024; 72:61-66. [PMID: 38640008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
In addition to the proper selection of techniques, appropriate treatment sequencing and prioritization are prerequisites for successful periodontal and implant procedures. The aim of this study was to provide evidence-based time frames for various procedures pertaining to periodontal and implant treatment. A literature review was conducted to collect data on tissue healing; in areas in which data were lacking, the viewpoints of experienced clinicians were solicited to establish a consensus. This review reports recommended time frames for the healing processes associated with surgical crown-lengthening procedures (both functional and esthetic), fresh socket management, alveolar ridge management, soft tissue management, sinus floor augmentation, implant loading, and peri-implant defect management.
Collapse
|
49
|
Addy LD. An introduction to dental implants. Br Dent J 2024; 236:753-757. [PMID: 38789751 DOI: 10.1038/s41415-024-7430-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 05/26/2024]
Abstract
The use of implants to replace missing teeth is now commonplace and practised by clinicians worldwide in both general and specialist practice. There is an abundance of evidence on the general success of implant treatment. As well as reviewing the history of dental implants, this narrative review will discuss the merits and successful placement of tissue-level verses bone-level implants. Furthermore, the article will evaluate the concept and benefits of platform switching for implant treatment. Finally, with the increased placement of implants, this narrative paper will review how different titanium surfaces impact on the risk of peri-implantitis.
Collapse
|
50
|
Qian Y, Zhao Y, Lu Y, Bao S, Zhu W, Chen Q, Si M. Clinical and radiographic outcomes of lateral sinus floor elevation with simultaneous hydrophilic implants placement: A retrospective study of 2-5 years. Clin Oral Implants Res 2024; 35:534-546. [PMID: 38366692 DOI: 10.1111/clr.14249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 01/13/2024] [Accepted: 02/05/2024] [Indexed: 02/18/2024]
Abstract
AIMS To investigate the clinical and radiographic outcomes of a chemically modified sandblasted large-grit acid-etched implant (hydrophilic) in lateral sinus floor elevation (LSFE), compared with a conventional one (hydrophobic). MATERIALS AND METHODS A retrospective study design was adopted. Patients who received LSFE with simultaneous implant placement were recruited. According to different types of implant surfaces, patients were divided into two groups (the hydrophilic group and the hydrophobic group). Implant survival rate (SR), endo-sinus bone stability on the radiographs, mean probing depths, percentage of bleeding on probing, marginal bone loss, and patient satisfaction were evaluated. RESULTS A total of 106 patients with 180 implants (hydrophilic:101, hydrophobic:79) in 119 maxillary sinuses were included. The follow-up period ranged from 2 to 5 years. Three hydrophobic implants and one hydrophilic implant in four different patients failed. The SR of the hydrophilic group was higher than that of the hydrophobic group but without a significant difference (p > .05). The change and change rate of endo-sinus bone height (ΔESBH and RΔESBH) and bone volume (ΔESBV and RΔESBV) in the hydrophilic group were less than those in the hydrophobic group, with a significant difference at 6 months after implantation. No other significant difference was found between the two groups. CONCLUSION Within the limitations of this study, both hydrophilic and hydrophobic implants were suitable for LSFE with predictable clinical outcomes. Meanwhile, hydrophilic implants could contribute to the grafted endo-sinus bone stability during healing time.
Collapse
|