26
|
Spiotta AM, Park MS, Bellon RJ, Bohnstedt BN, Schirmer CM, De Leacy RA, Fiorella DJ, Yoo AJ, Dumont TM, Starke RM. Technical Success and Early Efficacy in 851 Patients with Saccular Intracranial Aneurysms: A Subset Analysis of SMART, a Prospective, Multicenter Registry Assessing the Embolization of Neurovascular Lesions using the Penumbra SMART COIL System. World Neurosurg 2021; 155:e323-e334. [PMID: 34419663 DOI: 10.1016/j.wneu.2021.08.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVE The Prospective, Multicenter Registry Assessing the Embolization of Neurovascular Lesions Using the Penumbra SMART COIL® System (SMART) is the largest prospective, multicenter, postmarket registry established to gather real-world experience on Penumbra (Alameda, USA) SMART COIL System, PC400, and POD embolization coils. The goal of this study is to report the technical success and efficacy of SMART COIL System coils in treating saccular intracranial aneurysms. METHODS This subgroup analysis from the SMART registry included patients with saccular intracranial aneurysms treated using ≥75% SMART COIL System or PC400 coils. Baseline and procedural data, angiographic data, and clinical outcomes were collected. Predictors of catheter kickout, packing density, and postprocedural angiographic outcome were analyzed using multivariable regression models in saccular aneurysm cases. RESULTS Between June 2016 and August 2018, the SMART registry enrolled 995 patients at 68 sites, of which 851 of 995 (85.5%) were treated for saccular aneurysms (mean age, 59.9 years). Aneurysms had a mean size of 6.8 mm, were wide neck in 63.1%, and ruptured in 31.0% of patients. Mean aneurysm packing density was 32.3%. Postprocedural Raymond-Roy Occlusion Classification (RROC) I-II was achieved in 80.3% of patients; smaller aneurysms, non-wide-neck aneurysms, and high packing density were predictive of RROC I-II. Overall, mean fluoroscopic time was 43.4 minutes, rate of reaccess attempts because of catheter kickout was 6.2%, and mean procedure time was 83.2 minutes. CONCLUSIONS SMART COIL System coils achieved good technical success and adequate occlusion in treating saccular intracranial aneurysms in a real-world setting.
Collapse
|
27
|
Vardar Z, King RM, Kraitem A, Langan ET, Peterson LM, Duncan BH, Raskett CM, Anagnostakou V, Gounis MJ, Puri AS, Ughi GJ. High-resolution image-guided WEB aneurysm embolization by high-frequency optical coherence tomography. J Neurointerv Surg 2021; 13:669-673. [PMID: 32989033 PMCID: PMC8205185 DOI: 10.1136/neurintsurg-2020-016447] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 12/30/2022]
Abstract
BACKGROUND High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates. METHODS In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device. HF-OCT and digital subtraction angiography (DSA) were performed following WEB deployment and repeated at 4, 8, and 12 weeks. Protrusion (0-present, 1-absent) and malapposition (0-malapposed, 1-neck apposition >50%) were binary coded. A device was considered 'adequately deployed' by HF-OCT and DSA if apposed and non-protruding. Aneurysm healing on DSA was reported using the 4-point WEB occlusion score: A or B grades were considered positive outcome. Neointimal coverage was quantified on HF-OCT images at 12 weeks and compared with scanning electron microscopy (SEM). RESULTS Adequate deployment on HF-OCT correlated with positive outcome (P=0.007), but no statistically significant relationship was found between good outcome and adequate deployment on DSA (P=0.289). Absence of protrusion on HF-OCT correlated with a positive outcome (P=0.006); however, malapposition alone had no significant relationship (P=0.19). HF-OCT showed a strong correlation with SEM for the assessment of areas of neointimal tissue (R²=0.96; P<0.001). More neointimal coverage of 78%±32% was found on 'adequate deployment' cases versus 31%±24% for the 'inadequate deployment' cases (P=0.001). CONCLUSION HF-OCT visualizes features that can determine adequate device deployment to prognosticate early aneurysm occlusion following WEB implantation and can be used to longitudinally monitor aneurysm healing progression.
Collapse
|
28
|
Galhotra S, Mourad J. Intraoperative view of ovarian vein coils for embolization. Am J Obstet Gynecol 2021; 225:92-93. [PMID: 33631111 DOI: 10.1016/j.ajog.2021.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/14/2021] [Accepted: 02/17/2021] [Indexed: 11/18/2022]
|
29
|
Xia JL, Li GL, Liu HE, Feng-Fei X, Gu XD. Flow-diverting device versus coil embolization for unruptured intracranial aneurysm: A meta-analysis. Medicine (Baltimore) 2021; 100:e26351. [PMID: 34128887 PMCID: PMC8213299 DOI: 10.1097/md.0000000000026351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 05/28/2021] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Both coil embolization (CE) and flow-diverting device (FDD) placement are widely used for treatment of intracranial aneurysms (IAs). The aim of this meta-analysis is to compare the relative clinical safety and efficacy of FDD and CE for the treatment of unruptured IAs. METHODS The PubMed, Embase, and Cochrane Library databases were searched for relevant studies from the date of inception through April 2020. The primary endpoint for this meta-analysis was the 6-month rate of complete occlusion, while secondary endpoints included rates of retreatment, complications, and parental arterial patency. RESULTS This meta-analysis includes 8 studies, which included 839 total patients that underwent FDD and 2734 that underwent CE. FDD group exhibited a significantly higher pooled 6-month complete occlusion rate (P = .02). The subgroup analysis demonstrated that FDD treatment was associated with significantly higher pooled 6-month complete occlusion rates in patients with large or giant IAs (P < .00001), whereas no differences in 6-month complete occlusion rates were observed between the FDD and CE groups of patients with non-large/giant IAs (P = .83). The pooled retreatment (P = .16) and complication (P = .15) rates were comparable between 2 groups. The CE group exhibited significantly higher pooled parent artery patency rate (P = .01). The funnel plots did not reveal any evidence of publication bias. CONCLUSIONS FDDs can be used to effectively and safely treat large and giant IAs, achieving higher rates of complete occlusion than CE treatment. For non-large/giant IAs, we observed comparable efficacy between FDD and CE treatments.
Collapse
|
30
|
Ko HC. Rescue balloon-assisted remodeling technique for protrusion of coil loop: A case report. Medicine (Baltimore) 2021; 100:e25783. [PMID: 34106612 PMCID: PMC8133059 DOI: 10.1097/md.0000000000025783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 04/15/2021] [Indexed: 11/26/2022] Open
Abstract
RATIONALE Among the possible complications during endovascular embolization of intracranial aneurysms, coil protrusion into the parent artery is associated with parent artery occlusion or thromboembolic of the distal arteries. There is no clearly established management strategy for coil protrusion. This report demonstrates our experience with balloon-assisted remodeling to reposition a protruded coil loop. PATIENT CONCERNS A 53-year-old man was admitted to our hospital with severe bursting headache, nausea, and vomiting. Computed tomography showed subarachnoid hemorrhage and digital subtraction angiography revealed an anterior communicating artery aneurysm. We decided to obliterate the aneurysm with endovascular embolization using detachable coils. DIAGNOSIS A small loop protruded into the parent artery during the removal of the microcatheter. INTERVENTIONS We performed successful repositioning of the protruded coil loop using balloon inflation. CONCLUSION The rescue balloon-assisted remodeling technique was useful in the management of protrusion of a small coil loop into the parent artery during endovascular coil embolization of an intracranial aneurysm. The procedure was associated with minimal complications.
Collapse
|
31
|
Abstract
Aneurysmal subarachnoid hemorrhage is a neurologic emergency that requires immediate patient stabilization and prompt diagnosis and treatment. Early measures should focus on principles of advanced cardiovascular life support. The aneurysm should be evaluated and treated in a comprehensive stroke center by a multidisciplinary team capable of endovascular and, operative approaches. Once the aneurysm is secured, the patient is best managed by a dedicated neurocritical care service to prevent and manage complications, including a syndrome of delayed neurologic decline. The goal of such specialized care is to prevent secondary injury, reduce length of stay, and improve outcomes for survivors of the disease.
Collapse
|
32
|
Lim J, Choi G, Joo KI, Cha HJ, Kim J. Embolization of Vascular Malformations via In Situ Photocrosslinking of Mechanically Reinforced Alginate Microfibers using an Optical-Fiber-Integrated Microfluidic Device. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2006759. [PMID: 33543521 DOI: 10.1002/adma.202006759] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 12/12/2020] [Indexed: 06/12/2023]
Abstract
Embolization, which is a minimally invasive endovascular treatment, is a safe and effective procedure for treating vascular malformations (e.g., aneurysms). Hydrogel microfibers obtained via spatiotemporally controllable in situ photocrosslinking exhibit great potential for embolizing aneurysms. However, this process is challenging because of the absence of biocompatible and morphologically stable hydrogels and the difficulty in continuously spinning the microfibers via in situ photocrosslinking in extreme endovascular environments such as those involving a tortuous geometry and high absorbance. A double-crosslinked alginate-based hydrogel with tantalum nanopowder (DAT) that exploits the synergistic effect of covalent crosslinking by visible-light irradiation and ionic crosslinking using Ca2+ , which is present in the blood, is developed in this study. Furthermore, an effective strategy to design and produce an optical-fiber-integrated microfluidic device (OFI-MD) that can continuously spin hydrogel microfibers via in situ photocrosslinking in extreme endovascular environments is proposed. As an embolic material, DAT exhibits promising characteristics such as radiopacity, nondissociation, nonswelling, and constant mechanical strength in blood, in addition to excellent cyto- and hemo-compatibilities. Using OFI-MD to spin DAT microfibers continuously can help fill aneurysms safely, uniformly, and completely within the endovascular simulator without generating microscopic fragments, which demonstrates its potential as an effective embolization strategy.
Collapse
|
33
|
Wang T, Richard SA, Jiao H, Li J, Lin S, Zhang C, Wang C, Xie X, You C. Institutional experience of in-stent stenosis after pipeline flow diverter implantation: A retrospective analysis of 6 isolated cases out of 118 patients. Medicine (Baltimore) 2021; 100:e25149. [PMID: 33725998 PMCID: PMC7982244 DOI: 10.1097/md.0000000000025149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 02/22/2021] [Indexed: 02/05/2023] Open
Abstract
Pipeline embolization devices (PLEDs) are flow diverting stents that have exhibited be safe and efficient in the treatment of complex aneurysms. Nevertheless, in-stent stenosis (ISS) has been reported as one of the cardinal complications associated with PLED. The association of wall malapposition and ISS in patient treated with PLED has not been reported.A retrospective study was conducted to identify patients with ISS after implantation of PLED as treatment for intracranial aneurysms from April 25, 2018 to April 24, 2019. Incidence of ISS and its associated causes such as sharp change of the PLED, distal wall malapposition, inconsistent compliance between parent artery as well as the PLED occlusion due to intimal hyperplasia and vessel tortuosity. Assessment of conservative treatment and retreatment outcomes of ISS were documented.In all, 6 ISS cases were identified by 2 independent neurointerventionalists out of 118 aneurysm patients treated with PLED. Thus, the incidence rate of ISS in patients treated with PLED was as low as 5% at our institution compared to other studies. The follow-up time for detection of ISS ranged from 6 to 12 months after implantation. Several combinations of reasons such as sharp change of the PLED, distal wall malapposition, inconsistent compliance between parent arteries as well as PLED occlusion due to intimal hyperplasia and vessel tortuosity accounted for the causes of ISS during our analysis. Conservative treatment with a combination of antiplatelet during follow-ups did not resolve the ISS in our study probably due to associated underlying factors above.
Collapse
|
34
|
Zimmer S, Maus V, Maurer C, Berlis A, Weber W, Fischer S. Widening the Indications for Intrasaccular Flow Disruption: WEB 17 in the Treatment of Aneurysm Locations Different from Those in the Good Clinical Practice Trials. AJNR Am J Neuroradiol 2021; 42:524-529. [PMID: 33509918 DOI: 10.3174/ajnr.a6946] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 10/12/2020] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND PURPOSE The safety and efficacy of the Woven EndoBridge (WEB) device has been shown in multiple good clinical practice trials, whereas aneurysm locations in these trials were restricted to bifurcation aneurysms located at the circle of Willis (MCA bifurcation, ICA bifurcation, anterior communicating artery, basilar artery tip). Our aim was to evaluate angiographic and clinical results with the WEB 17 in aneurysm locations that were excluded from the good clinical practice trials, assuming that the angiographic and clinical results are similar to those of the good clinical practice trials for aneurysms in traditional locations. MATERIALS AND METHODS We performed retrospective analysis of immediate and follow-up results of aneurysms in locations outside the good clinical practice trials in which the WEB 17 was used on an intention-to-treat approach. RESULTS Between June 2017 and May 2020, forty-seven aneurysms in 44 patients met the inclusion criteria. Aneurysm locations were the ICA posterior communicating artery in 19 (40.3%), the ICA paraophthalmic or choroidal locations in 4 (8.6%), anterior cerebral artery A2 segment in 13 (27.7%), MCA M1 segment in 2 (4.3%), posterior cerebral artery P2 segment in 2 (4.3%), PICA in 3 (6.4%), and the superior cerebellar artery in 4 (8.4%) cases. The procedure-related morbidity and mortality rates in the entire series were 0.0%. The early and late (<12 and >12 months) complete occlusion rates were 63.9% (23/36) and 77.8% (14/18), respectively. CONCLUSIONS The WEB 17 is safe and effective in aneurysm locations different from the traditional bifurcation aneurysms included in the good clinical practice trials. Further studies will help to define the entire spectrum of aneurysm morphologies and locations suitable for the WEB 17.
Collapse
|
35
|
Lobsien D, Clajus C, Behme D, Ernst M, Riedel CH, Abu-Fares O, Götz FG, Fiorella D, Klisch J. Aneurysm Treatment in Acute SAH with Hydrophilic-Coated Flow Diverters under Single-Antiplatelet Therapy: A 3-Center Experience. AJNR Am J Neuroradiol 2021; 42:508-515. [PMID: 33446495 DOI: 10.3174/ajnr.a6942] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 10/05/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND PURPOSE In certain clinical circumstances, dual-antiplatelet therapy can be problematic in patients with acute SAH. In some aneurysms, however, flow-diverting stents are the ideal therapeutic option. We report our experience with ruptured intracranial aneurysms treated with flow diverters with hydrophilic coating (p48 MW HPC and p64 MW HPC) under single-antiplatelet therapy. MATERIALS AND METHODS Patients were treated with either flow-diverter placement alone or a flow diverter and additional coiling. Due to the severity of the hemorrhage, the potential for periprocedural rehemorrhage, and the potential for additional surgical interventions, a single-antiplatelet regimen was used in all patients. RESULTS Thirteen aneurysms were treated in 10 patients. The median age was 62 years; 5 patients were male. All had acute SAH due to aneurysm rupture. Four blood-blister, 2 dissecting, and 7 berrylike aneurysms were treated. Seven aneurysms were adjunctively coiled. Eight of the 10 patients received a single-antiplatelet protocol of aspirin, 1 patient was treated with prasugrel only, and 1 patient was treated with tirofiban first and then switched to the aspirin single-antiplatelet protocol. One device-related complication occurred, a thrombosis of an overstented branch. All stents, however, remained open at DSA, CTA, or MRA follow-up. CONCLUSIONS The implantation of flow diverters with reduced thrombogenicity due to hydrophilic surface coating under single-antiplatelet therapy seems to be an option in carefully selected cases of SAH due to aneurysm rupture.
Collapse
|
36
|
Lim J, Vakharia K, Waqas M, Affana C, Siddiqui AH, Davies JM, Levy EI. Comaneci Device for Temporary Coiling Assistance for Treatment of Wide-Necked Aneurysms: Initial Case Series and Systematic Literature Review. World Neurosurg 2021; 149:e85-e91. [PMID: 33640525 DOI: 10.1016/j.wneu.2021.02.080] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Coiling of wide-necked aneurysms requires high-density packing of coils within the aneurysm, which necessitates adequate microcatheter access and navigability. The Comaneci device, introduced in the United States in 2019, is a retrievable stent that can be used as an adjunct to coiling of a wide-necked aneurysm without limiting flow. We present a case series and systematic review of use of this device. METHODS All cases involving use of the device at our institute between May 1, 2019, and April 30, 2020, were reviewed. A comprehensive systematic review of the literature was conducted using PubMed and EMBASE and a review of eligible article bibliographies. RESULTS Five patients underwent Comaneci-assisted wide-necked aneurysm coiling during the study period; 4 were treated via a radial artery approach, and 1 was treated via a femoral artery approach. Two patients presented with subarachnoid hemorrhage: 1 had a ruptured posterior inferior cerebellar artery aneurysm (Hunt-Hess 5, Fisher 4), and 1 had a ruptured middle cerebral artery aneurysm (Hunt-Hess 2, Fisher 1). Mean aneurysmal neck size was 4.4 ± 0.8mm; mean aspect ratio was 1.2 ± 0.3. Raymond-Roy 1 occlusion was achieved in all aneurysms except the posterior inferior cerebellar artery aneurysm. Systematic literature review identified 4 articles that found use of the Comaneci device to treat wide-necked aneurysms to be effective. CONCLUSIONS This device can be used with transfemoral and transradial approaches, allowing for continued flow through the parent vessel during the coiling procedure while providing a scaffold for dense coiling of the aneurysm and its neck.
Collapse
|
37
|
Ghorbani M, Lafta G, Rahbarian F, Mortazavi A. Treatment of post-traumatic direct carotid-cavernous fistulas using flow diverting stents: Is it alone satisfactory? J Clin Neurosci 2021; 86:230-234. [PMID: 33775333 DOI: 10.1016/j.jocn.2021.01.047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 01/08/2021] [Accepted: 01/28/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND Direct carotid cavernous fistula (CCF) occurs between the internal carotid artery (ICA) and the cavernous sinus. Carotid cavernous fistulas (CCFs) frequently present with chemosis, pulsatile proptosis, ocular bruit, vision loss, and occasionally intracerebral hemorrhage or seizure. In this article, we share our experience in endovascular treatment of six patients having this pathology with intracranial flow diverting stents with review of literatures. CASE DESCRIPTION All six patients had posttraumatic direct CCF, most of their signs and symptoms were visual disturbance, chemosis, orbital bruit, headache, paralysis of extraocular muscles. They were treated with flow diversion stents with or without coils or liquid embolizing material; transvenous and transarterial routes were used. Most of them underwent multiple sessions, and their conditions were improved dramatically. CONCLUSION The best and most effective method is to start the procedure by coiling to convert the high-flow fistula to an aneurysmal pouch with the smallest possible size in the cavernous sinus, and then close the defect site with one or two flow diversion devices (FDDs).
Collapse
|
38
|
Ding Y, Dai D, Rouchaud A, Janot K, Asnafi S, Kallmes DF, Kadirvel R. WEB Device Shape Changes in Elastase-Induced Aneurysms in Rabbits. AJNR Am J Neuroradiol 2021; 42:334-339. [PMID: 33303525 PMCID: PMC7872195 DOI: 10.3174/ajnr.a6899] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Accepted: 09/05/2020] [Indexed: 12/31/2022]
Abstract
BACKGROUND AND PURPOSE While WEB devices have been shown to be safe and effective for aneurysm treatment, WEB-shape modification compression has been associated with incomplete aneurysm occlusion. We explored the relationship between occlusion rates and WEB-shape modification in different WEB device types in an experimental aneurysm model. MATERIALS AND METHODS Elastase-induced aneurysms were created in rabbits and treated with dual-layer (n = 12), single-layer (n = 12), or single-layer sphere (n = 12) WEB devices. Aneurysms were followed up either at 3 or 12 months. Angiographic occlusion was graded using the WEB Occlusion Scale: grade I, complete; grade II, complete but recess filling; grade III, residual neck; or grade IV, residual aneurysm. WEB-shape modification and histologic features were also analyzed. RESULTS Grade I or II occlusion was seen in 16 (44%) aneurysms, and grade I, II, or III ("adequate") occlusion was observed in 22 (61.1%) aneurysms at follow-up. WEB-shape modification was observed in 22 (61.1%) aneurysms. WEB-shape modification was higher in single-layer (9/12) and dual-layer (10/12) devices compared with single-layer sphere devices (3/12). Aneurysms with WEB-shape modification had a higher level of thrombus organization in the dome compared with those without WEB-shape modification (68% [15/22] versus 50% [7/14]). WEB-shape modification was not correlated with angiographic or histologic outcomes but was significantly correlated with levels of fibrosis and smooth muscle cells in the aneurysm. CONCLUSIONS WEB-shape modification is not associated with incomplete aneurysm occlusion of WEB devices in the rabbit model but may be related to connective tissue formation and the healing response to WEB device implantation.
Collapse
|
39
|
Sunohara T, Imamura H, Goto M, Fukumitsu R, Matsumoto S, Fukui N, Oomura Y, Akiyama T, Fukuda T, Go K, Kajiura S, Shigeyasu M, Asakura K, Horii R, Sakai C, Sakai N. Neck Location on the Outer Convexity is a Predictor of Incomplete Occlusion in Treatment with the Pipeline Embolization Device: Clinical and Angiographic Outcomes. AJNR Am J Neuroradiol 2021; 42:119-125. [PMID: 33184073 DOI: 10.3174/ajnr.a6859] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 08/11/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND PURPOSE With the increasing use of the Pipeline Embolization Device for the treatment of aneurysms, predictors of clinical and angiographic outcomes are needed. This study aimed to identify predictors of incomplete occlusion at last angiographic follow-up. MATERIALS AND METHODS In our retrospective, single-center cohort study, 105 ICA aneurysms in 89 subjects were treated with Pipeline Embolization Devices. Patients were followed per standardized protocol. Clinical and angiographic outcomes were analyzed. We introduced a new morphologic classification based on the included angle of the parent artery against the neck location: outer convexity type (included angle, <160°), inner convexity type (included angle, >200°), and lateral wall type (160° ≤ included angle ≤200°). This classification reflects the metal coverage rate and flow dynamics. RESULTS Imaging data were acquired in 95.3% of aneurysms persistent at 6 months. Complete occlusion was achieved in 70.5%, and incomplete occlusion, in 29.5% at last follow-up. Multivariable regression analysis revealed that 60 years of age or older (OR, 5.70; P = .001), aneurysms with the branching artery from the dome (OR, 10.56; P = .002), fusiform aneurysms (OR, 10.2; P = .009), and outer convexity-type saccular aneurysms (versus inner convexity type: OR, 30.3; P < .001; versus lateral wall type: OR, 9.71; P = .001) were independently associated with a higher rate of incomplete occlusion at the last follow-up. No permanent neurologic deficits or rupture were observed in the follow-up period. CONCLUSIONS The aneurysm neck located on the outer convexity is a new, incomplete occlusion predictor, joining older age, fusiform aneurysms, and aneurysms with the branching artery from the dome. No permanent neurologic deficits or rupture was observed in the follow-up, even with incomplete occlusion.
Collapse
|
40
|
Altun I, Hu J, Albadawi H, Zhang Z, Salomao MA, Mayer JL, Jamal L, Oklu R. Blood-Derived Biomaterial for Catheter-Directed Arterial Embolization. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e2005603. [PMID: 33174305 PMCID: PMC7769968 DOI: 10.1002/adma.202005603] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 10/05/2020] [Indexed: 05/05/2023]
Abstract
Vascular embolization is a life-saving minimally invasive catheter-based procedure performed to treat bleeding vessels. Through these catheters, numerous metallic coils are often pushed into the bleeding artery to stop the blood flow. While there are numerous drawbacks to coil embolization, physician expertise, availability of these coils, and their costs further limit their use. Here, a novel blood-derived embolic material (BEM) with regenerative properties, that can achieve instant and durable intra-arterial hemostasis regardless of coagulopathy, is developed. In a large animal model of vascular embolization, it is shown that the BEM can be prepared at the point-of-care within 26 min using fresh blood, it can be easily delivered using clinical catheters to embolize renal and iliac arteries, and it can achieve rapid hemostasis in acutely injured vessels. In swine arteries, the BEM increases cellular proliferation, angiogenesis, and connective tissue deposition, suggesting vessel healing and durable vessel occlusion. The BEM has significant advantages over embolic materials used today, making it a promising new tool for embolization.
Collapse
|
41
|
Liang S, Yuan R, Lv X. A novel treatment of a patient with a giant ruptured middle cerebral artery aneurysm by acute coiling followed by scheduled Pipeline flex placement. Neuroradiol J 2020; 33:517-519. [PMID: 32673144 PMCID: PMC7788672 DOI: 10.1177/1971400920941192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE Flow diversion in the acute phase of aneurysm rupture or giant aneurysm is limited by the need for dual antiplatelet therapy and the risk of delayed aneurysm rupture. Here, the authors report a scheduled flow-diversion concept for the endovascular treatment of a giant intra-dural aneurysm. METHODS A 54-year-old female patient with a ruptured giant middle cerebral artery aneurysm underwent coiling in the acute phase following 1-month scheduled Pipeline flex placement. RESULTS The acutely ruptured giant middle cerebral artery aneurysm was treated by flow diversion scheduled at 1 month after conventional coiling. The patient tolerated this treatment strategy well without any neurological deficits after the procedure and during the 3-month follow-up. The aneurysm showed nearly complete obliteration on 3-month follow-up angiogram, and a 6- to 12-month follow-up was scheduled. CONCLUSIONS This strategy may be considered as an option in patients presenting with ruptured or unruptured giant intra-dural aneurysms.
Collapse
|
42
|
Hou K, Li G, Lv X, Xu B, Xu K, Yu J. Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter. Neuroradiol J 2020; 33:451-464. [PMID: 32851918 PMCID: PMC7788679 DOI: 10.1177/1971400920953299] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Though flow diverter is a safe and efficient modality, some patients can experience delayed aneurysmal rupture. The mechanism of delayed rupture is still obscure to us. METHODS We performed a systematic search in the PubMed database for patients with delayed rupture of intracranial aneurysms after flow diverter placement. RESULTS A total of 36 articles reporting on 60 patients were included in the final analysis. Of the 49 patients with description of presenting symptoms, six (12.2%) patients were incidentally diagnosed, 39 (87.8%) patients were admitted for aneurysmal rupture or mass effect. Multiple flow diverters were used in 38.3% (18/47) of the patients. Coil assistance was applied in 13.0% (7/54) of the patients. Delayed aneurysmal rupture led to intracranial hemorrhage or carotid-cavernous sinus fistula (CCF) in 76.8% (43/56) and 23.2% (13/56) of the patients, respectively. Of the 55 patients with description of outcome, 14 (25.5%) patients achieved good recovery, one (1.8%) patient was severely disabled, 40 (72.7%) patients died. All of the patients in the CCF group survived and experienced good recovery. CONCLUSION Increased intra-aneurysmal pressure, destabilization of the aneurysm wall by intra-aneurysmal thrombus, persistent residual intra-aneurysmal flow, characteristics of the specific aneurysm, and mechanical injury by the flow diverter might conjointly contribute to the final delayed rupture. There has been no established preventive measure to decrease the incidence of delayed rupture yet. The treatment and outcome depend on the presentation of delayed rupture. Patients presenting with aneurysm-related intracranial hemorrhage have a dismal outcome. Those presenting with CCFs usually have a satisfactory recovery.
Collapse
|
43
|
Feng GJ, Gao F, Huang XY, Hati P, Yang XP, Wu HX. Efficacy and safety of endovascular coiling vs surgical clipping for patients with ruptured carotid-ophthalmic aneurysm: A protocol for systematic review and meta-analysis. Medicine (Baltimore) 2020; 99:e23235. [PMID: 33217840 PMCID: PMC7676553 DOI: 10.1097/md.0000000000023235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Carotid-ophthalmic aneurysms are relatively rare, and represent 1% of all intracranial aneurysms. Generally, endovascular coiling and surgical clipping are the 2 most commonly used methods to treat ruptured carotid-ophthalmic aneurysms, it provides the most favorable outcome for a patient. This study aims to assess the efficiency and safety of endovascular coiling vs surgical clipping for patients with a ruptured carotid-ophthalmic aneurysm. METHODS A comprehensive systematic literature review was done in PubMed, EMBASE, Cochrane Library, Web of Science, Scopus, China National Knowledge Infrastructure (CNKI), and WanFang databases. Only randomized trials that compared endovascular coiling with surgical clipping in patients with ruptured carotid-ophthalmic aneurysm was included. Data was extracted independently by 2 review authors. Moreover, the quality of study and bias risk was evaluated by utilizing an appropriate method. Triallists will be contacted to acquire missing information. The data is presented as risk ratio and mean difference, or standardized mean difference with 95% confidence intervals. RESULTS The results from the present research shall be published in a peer-reviewed journal. CONCLUSION The present study summarizes the direct and in-direct evidence to judge the efficiency and safety of these 2 methodologies to treat ruptured carotid-ophthalmic aneurysms and attempt to find the most efficiency and safety therapeutical method. ETHICS AND DISSEMINATION The present study is a meta-analysis based on published evidence. As a result, ethics approval and patient consent are not needed.
Collapse
|
44
|
Ospel JM, Brouwer P, Dorn F, Arthur A, Jensen ME, Nogueira R, Chapot R, Albuquerque F, Majoie C, Jayaraman M, Taylor A, Liu J, Fiehler J, Sakai N, Orlov K, Kallmes D, Fraser JF, Thibault L, Goyal M. Antiplatelet Management for Stent-Assisted Coiling and Flow Diversion of Ruptured Intracranial Aneurysms: A DELPHI Consensus Statement. AJNR Am J Neuroradiol 2020; 41:1856-1862. [PMID: 32943417 DOI: 10.3174/ajnr.a6814] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 06/30/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND PURPOSE There is a paucity of data regarding antiplatelet management strategies in the setting of stent-assisted coiling/flow diversion for ruptured intracranial aneurysms. This study aimed to identify current challenges in antiplatelet management during stent-assisted coiling/flow diversion for ruptured intracranial aneurysms and to outline possible antiplatelet management strategies. MATERIALS AND METHODS The modified DELPHI approach with an on-line questionnaire was sent in several iterations to an international, multidisciplinary panel of 15 neurointerventionalists. The first round consisted of open-ended questions, followed by closed-ended questions in the subsequent rounds. Responses were analyzed in an anonymous fashion and summarized in the final manuscript draft. The statement received endorsement from the World Federation of Interventional and Therapeutic Neuroradiology, the Japanese Society for Neuroendovascular Therapy, and the Chinese Neurosurgical Society. RESULTS Data were collected from December 9, 2019, to March 13, 2020. Panel members achieved consensus that platelet function testing may not be necessary and that antiplatelet management for stent-assisted coiling and flow diversion of ruptured intracranial aneurysms can follow the same principles. Preprocedural placement of a ventricular drain was thought to be beneficial in cases with a high risk of hydrocephalus. A periprocedural dual, intravenous, antiplatelet regimen with aspirin and a glycoprotein IIb/IIIa inhibitor was preferred as a standard approach. The panel agreed that intravenous medication can be converted to oral aspirin and an oral P2Y12 inhibitor within 24 hours after the procedure. CONCLUSIONS More and better data on antiplatelet management of patients with ruptured intracranial aneurysms undergoing stent-assisted coiling or flow diversion are urgently needed. Panel members in this DELPHI consensus study preferred a periprocedural dual-antiplatelet regimen with aspirin and a glycoprotein IIb/IIIa inhibitor.
Collapse
|
45
|
Sirakov A, Bhogal P, Möhlenbruch M, Sirakov S. Endovascular treatment of patients with intracranial aneurysms: feasibility and successful employment of a new low profile visible intraluminal support (LVIS) EVO stent. Neuroradiol J 2020; 33:377-385. [PMID: 32692304 PMCID: PMC7482042 DOI: 10.1177/1971400920941402] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND AND PURPOSE Low-profile self-expandable stents have increased the number of intracranial aneurysms treated by endovascular means. The new low-profile visible intraluminal support device LVIS EVO (Microvention), the successor of LVIS Jr, is a self-expandable and retrievable microstent system, designed for implantation into intracranial arteries with a diameter up to 2.0 mm. In this retrospective study we aimed to elucidate the technical feasibility and clinical safety of the novel LVIS EVO stent for stent-assisted coil embolisation of intracranial aneurysms. MATERIALS AND METHODS A single centre technical report of the first six consecutive cases of stent-assisted coil embolisation with the novel LVIS EVO stent for the treatment of unruptured or recanalised intracranial aneurysms. Records were made of basic demographics, aneurysmal characteristics, device properties and related technical details, adverse events, clinical outcomes and occlusion rates on available radiological follow-up. RESULTS Six LVIS EVO devices were successfully implanted in all subjects to treat a total number of six intracranial aneurysms. No device-related intraprocedural complications were seen. At early clinical follow-up six out of six (100%) patients had a modified Ranking score of 0-1. Early angiographic and cross-sectional radiological follow-up, available in five out of six (83.3%) of the patients confirmed unchanged aneurysmal occlusion rates. A minor, transitory neurological deficit was recorded in one of the six (16.6%) patients. Mortality was 0%. CONCLUSIONS Preliminary experience in this subset of our patients confirms a notably improved technical behaviour of the novel LVIS EVO stent system when compared to its ancestor LVIS Jr. The enhanced visibility of the stent and the refined delivery/retrieval capabilities of the stent further increase the safety margins of the devices profile, especially in cases of tortuous anatomy.
Collapse
|
46
|
Harada T, Fujita A, Sakata J, Kohta M, Kohmura E. Endovascular Internal Trapping by Low-Concentration N-butyl-2-Cyanoacrylate for a Ruptured Giant Common Carotid Artery Pseudoaneurysm. Vasc Endovascular Surg 2020; 55:81-85. [PMID: 32873222 DOI: 10.1177/1538574420953942] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Treating carotid blowout syndrome following rupture of giant pseudoaneurysms is difficult because the destroyed parent artery precludes conventional treatment. We present a patient with a ruptured giant pseudoaneurysm that we occluded using a modified internal trapping technique with low-concentration N-butyl-2-cyanoacrylate (NBCA) and a minimum number of coils. An 80-year-old man with a history of chemoradiation therapy for oropharyngeal cancer presented with several episodes of active bleeding from the subsequent tracheostomy site. Radiological examination revealed a giant right common carotid artery (CCA) pseudoaneurysm. Endovascular internal trapping was performed using both NBCA and coils under proximal flow control. We slowly injected 9 ml of low-concentration NBCA, which subsequently filled the entire pseudoaneurysm. We then injected an additional 2 ml of NBCA into the proximal CCA to achieve complete obliteration. No re-bleeding was observed during the 6-month follow-up. Endovascular internal trapping using low-concentration NBCA was feasible to treat a giant CCA pseudoaneurysm. The injected low-concentration NBCA filled the entire pseudoaneurysm without the risk of catheter entrapment.
Collapse
|
47
|
Sticco A, Gandhi SS, Knoedler B, Marston G, Ewing A, Langan EM, Carsten CG. Current Outcomes of Blunt Vertebral Artery Injuries. Ann Vasc Surg 2020; 70:252-257. [PMID: 32768545 DOI: 10.1016/j.avsg.2020.07.045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 07/14/2020] [Accepted: 07/21/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND There is no consensus on the treatment of blunt vertebral artery injuries, and studies are limited to small case series. We assessed the natural history and current management of these injuries. METHODS We performed a retrospective study of a prospectively collected registry at a level I trauma center over a 5-year period. Additional information was gathered from patient charts and imaging review from electronic medical records. We analyzed demographics, mechanism of injury, Glasgow Coma Score, mortality, length of stay, associated injuries, Denver grading scale, neurological findings, level and laterality of injury, delay in diagnosis, treatment, and follow-up imaging. RESULTS There were 13,080 trauma admissions during this time period yielding 141 patients with blunt vertebral artery injuries from 2013 to 2018 (1.1% incidence). Mean injury severity score (ISS) was 22 with a 30-day mortality of 14 (9.9%). An ISS of greater than 15 is associated with polytrauma and increased mortality. There were 112 (79.4%) associated cervical fractures. C6 and C7 were both equally the most common locations. There was one symptomatic injury manifesting as a cerebellar ischemic infarct. The degree of arterial injury was classified by the Denver grading scale. There were 61 (43.3%) instances of Denver grade I injuries, followed by grade IV at 36 (25.5%), grade II at 34 (24.1%), grade III at 8 (5.7%), and grade V at 1 (0.7%). The level of injury was recorded as follows: V2 = 67 (47.5%), V3 = 56 (39.7%), V1 = 48 (34%), V4 = 14 (9.9%). Medical therapy included aspirin in 93 patients (66%), 31 patients (22%) received systemic anticoagulation with heparin drip, and 2 patients (1%) were administered therapeutic Lovenox. A total of 15 patients (11%) received no medical treatment. There was one intervention in our series. Our only grade V injury was coil embolized. A total of 118 patients (84%) had follow-up imaging. Seventy-eight patients (96%) with grade I and grade II injuries did not worsen, and complete radiographic resolution was found in 50 patients (62%). Grade IV injuries persisted in 22 patients (75.9%). Median time to resolution for grade I and grade II injuries was 7 and 8 days, respectively. Most follow-up scans for grade I and II injuries occurred within 50 days. CONCLUSIONS Posterior circulation stroke due to blunt vertebral artery injury is rare. In our experience, the natural course of blunt vertebral artery injury was benign and neither delay in medical treatment nor choice of antithrombotic had a significant impact on outcomes. In our series, only 3 (3.7%) grade I and II injuries worsened and were without any clinical sequelae. We suggest that routine serial imaging in grade I and II blunt vertebral injuries is not warranted.
Collapse
|
48
|
Kluckner M, Frech A. Treatment of a Type II Endoleak by Outflow Occlusion. Eur J Vasc Endovasc Surg 2020; 60:346. [PMID: 32732141 DOI: 10.1016/j.ejvs.2020.05.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 05/04/2020] [Accepted: 05/31/2020] [Indexed: 11/20/2022]
|
49
|
Pierot L, Moret J, Barreau X, Szikora I, Herbreteau D, Turjman F, Holtmannspötter M, Januel AC, Costalat V, Fiehler J, Klisch J, Gauvrit JY, Weber W, Desal H, Velasco S, Liebig T, Stockx L, Berkefeld J, Molyneux A, Byrne JV, Spelle L. Aneurysm Treatment With Woven EndoBridge in the Cumulative Population of 3 Prospective, Multicenter Series: 2-Year Follow-Up. Neurosurgery 2020; 87:357-367. [PMID: 31960052 PMCID: PMC7534535 DOI: 10.1093/neuros/nyz557] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Accepted: 11/10/2019] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Woven EndoBridge (WEB; Sequent Medical) treatment is an innovative endovascular approach for treatment of wide-neck bifurcation aneurysms. Initial studies have shown high safety with good efficacy at short term confirmed by trials conducted in United States (WEB-Intrasaccular Therapy) and in Europe (WEB Clinical Assessment of Intrasaccular Aneurysm Therapy [WEBCAST], French Observatory, and WEBCAST-2). OBJECTIVE To report the 2-yr clinical and anatomical results of WEB treatment in the combined population of 3 European trials. METHODS In a French Observatory, 2-yr clinical and anatomical data were collected. In WEBCAST and WEBCAST-2, 2-yr follow-up was optional, and data were collected when follow-up was performed. Aneurysm occlusion was evaluated using a 3-grade scale: complete occlusion, neck remnant, and aneurysm remnant. RESULTS The population for safety was 138/168 patients (82.1%), including 89 females (64.5%), with mean age of 55.5 ± 10.2 yr. The population for efficacy was 121/169 aneurysms (71.6%). Aneurysm locations were middle cerebral artery in 65/121 aneurysms (53.7%), anterior-communicating artery in 25/121 (20.7%), basilar artery in 17/121 (14.0%), and internal carotid artery terminus in 14/121 (11.6%). No clinically relevant adverse events occurred between years 1 and 2. At 2 yr, complete occlusion was observed in 62/121 (51.2%) aneurysms, neck remnant in 36/121 (29.8%) aneurysms, and aneurysm remnant in 23/121 (19.0%) aneurysms. The global retreatment rate at 2 yr was 9.3%. CONCLUSION This analysis confirms the high safety profile of WEB treatment at 2 yr. Aneurysm occlusion is generally stable at 2 yr, and the retreatment rate between 1 yr and 2 yr is low (2.0%).
Collapse
|
50
|
Al Saiegh F, Hasan D, Mouchtouris N, Zanaty M, Sweid A, Khanna O, Chalouhi N, Ghosh R, Tjoumakaris S, Gooch MR, Rosenwasser R, Jabbour P. Treatment of Acutely Ruptured Cerebral Aneurysms With the Woven EndoBridge Device: Experience Post-FDA Approval. Neurosurgery 2020; 87:E16-E22. [PMID: 32357228 PMCID: PMC8929032 DOI: 10.1093/neuros/nyaa092] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 01/30/2020] [Indexed: 09/21/2023] Open
Abstract
BACKGROUND Coil embolization of ruptured bifurcation aneurysms is challenging and often necessitates adjunctive stenting, which requires antiplatelet therapy in the setting of subarachnoid hemorrhage (SAH). The Woven EndoBridge (WEB; Terumo) device is an alternative self-expanding 3D mesh that does not require antiplatelet agents. However, its use has been mostly reserved for unruptured aneurysms. OBJECTIVE To assess the safety and feasibility of ruptured aneurysm treatment with the WEB. METHODS Retrospective analysis of 9 SAH patients with 11 aneurysms that were treated with the WEB device at 2 institutions after FDA approval. RESULTS Hunt and Hess grades were III and IV in 4 (44%) each and V in 1 (11%). All patients were treated within 24 h of hospitalization, and a single WEB was used in all but one aneurysm. Aneurysms treated were 3 basilar tip, 2 anterior communicating artery, 2 posterior inferior cerebellarartery, 1 middle cerebral artery, 1 carotid-ophthalmic artery, 1 posterior communicating artery, and 1 vertebrobasilar junction. Mean aneurysm height and width were 6.2 ± 2.2 mm (range: 3-10) and 5.6 ± 3.0 mm (range: 3.3-14), respectively. Mean dome-to-neck ratio was 1.7 ± 0.8 (range: 1.0-3.8). There was one intraoperative rupture that occurred because of device dislodgement and was managed with embolization. There were no treatment-related mortalities and no re-rupture after securement of the aneurysms with the WEB. CONCLUSION Our preliminary experience indicates that the WEB device can be used safely for ruptured aneurysms of various sizes in the anterior and posterior circulation. Larger series with long-term follow-up are necessary to confirm our findings.
Collapse
|