51
|
Espinosa G, Golzarri JI, Rickards J, Gammage RB. Study of gel materials as radioactive 222Rn gas detectors. RADIATION PROTECTION DOSIMETRY 2006; 119:425-9. [PMID: 16709716 DOI: 10.1093/rpd/nci512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Commercial hair gel material (polyvinyl pyrolydone triethanolamine carbopol in water) and bacteriological agar (phycocolloid extracted from a group of red-purple algae, usually Gelidium sp.) have been studied as radioactive radon gas detectors. The detection method is based on the diffusion of the radioactive gas in the gel material, and the subsequent measurement of trapped products of the natural decay of radon by gamma spectrometry. From the several radon daughters with gamma radiation emission (214Pb, 214Bi, 214Po, 210Pb, 210Po), two elements, 214Pb (0.352 MeV) and 214Bi (0.609 MeV), were chosen for the analysis in this work; in order to determine the best sensitivity, corrections were made for the short half-life of the analysed isotopes. For the gamma spectrometry analysis, a hyperpure germanium solid state detector was used, associated with a PC multichannel analyser card with Maestro and Microsoft Excel software. The results show the viability of the method: a linear response in a wide radon concentration range (450-10,000 Bq m(-3)), reproducibility of data, easy handling and low cost of the gel material. This detection methodology opens new possibilities for measurements of radon and other radioactive gases.
Collapse
|
52
|
Viti V, d'Errico F, Pacilio M, Luciani AM, Palma A, Grande S, Ranghiasci C, Adorante N, Guidoni L, Rosi A, Ranade M, de Pasquale F, Barone P, Sebastiani G. Optical imaging of dose distributions in Fricke gels. RADIATION PROTECTION DOSIMETRY 2006; 120:148-50. [PMID: 16614085 DOI: 10.1093/rpd/ncj005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Ferrous-sulphate infused gels, or 'Fricke gels', encounter great interest in the field of radiation dosimetry, due to their potential for 3D radiation dose mapping. Typically, magnetic resonance (MR) relaxation rates are determined in these systems in order to derive the absorbed dose. However, when large concentration gradients are present, diffusion effects before and during the MR imaging may not be negligible. In these cases, optical techniques may represent a viable alternative. This paper describes research aimed at measuring 3D dose distributions in a Fricke-xylenol orange gel by measuring optical density with a CCD camera. This method is inexpensive and fast. A series of early experiments is described, in which optical density profiles were measured with a commercial microdensitometer for film dosimetry. The light box of the device was modified to work at 567 nm, close to the maximum absorbance of the ferric ion-xylenol orange complex. Under these conditions, the gel shows linearity with dose and high sensitivity.
Collapse
|
53
|
Luciani AM, Palma A, Adorante N, Barone P, Grande S, Ranghiasci C, Rosi A, Guidoni L, Viti V. Optical images of dose distributions in Gel-Fricke: dosimetric performances of the gel. RADIATION PROTECTION DOSIMETRY 2006; 122:455-6. [PMID: 17186949 DOI: 10.1093/rpd/ncl486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The purpose of this work was to examine the dosimetric performances of the radiochromic Fricke-Agarose-Xylenol Orange gel by optical measurements in order to perform dose reconstructions, in view of a future development for 3-D maps. Optical images and dose-response curves of the gel were obtained by a CCD-based device, originally designed for reading radiochromic films, that was modified to meet the optical properties of the dosemeter. With a resolution of 0.18 x 0.18 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.1 Gy. With a resolution of 1.98 x 1.98 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 0.3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.015 Gy. The comparison with alanine dosemeters in the dose range 7-10 Gy showed agreement within a few per cent and the same agreement was observed for the comparison with TLD in the range 1-3 Gy.
Collapse
|
54
|
Abstract
BACKGROUND Transfusion-associated graft-versus-host disease is believed to be a preventable complication of blood transfusion in susceptible high-risk patients. Irradiation of allogeneic blood components is considered to be a safe and effective method inhibiting the proliferative capacity of lymphocytes. Physical factors that influence dose delivery include source and sample geometry, homogeneity of the dose distribution within the irradiation volume, and factors that influence dose absorption within the sample. STUDY DESIGN AND METHODS Polymer gel dosimetry was used to evaluate the three-dimensional dose distribution for blood bags, platelet (PLT) bags, and syringes in typical geometries. RESULTS The qualitative dose distribution within a cylindrical phantom determined with the polymer gel was in good agreement with the distribution in water determined with a DOSE-MAP film dosimetry system. Dose uniformity in blood bags and syringes was acceptable. Low signal strength and volume averaging hamper determination of the dose in PLT bags. CONCLUSION Geometrical considerations in routine blood product irradiation may be evaluated with the use of polymer gel dosimetry. The procedures, however, are highly technical and are susceptible to low signal-to-noise and volume averaging considerations under certain geometrical configurations. Under clinical conditions, a reasonably uniform dose can be delivered to blood and blood components in a freestanding irradiator.
Collapse
|
55
|
Saur S, Strickert T, Wasboe E, Frengen J. Fricke gel as a tool for dose distribution verification: optimization and characterization. Phys Med Biol 2005; 50:5251-61. [PMID: 16264251 DOI: 10.1088/0031-9155/50/22/003] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
With the introduction of conformal techniques in radiation therapy, gel dosimetry plays an important role as a 3D dose verification system. There are two main types of gels in use for dosimetry: Fricke gels and polymer gels. The advantages of polymer gels are improved dose response and stability with no diffusion problems. However, the more complicated fabrication procedure and the greater cost compared to Fricke gels makes polymer gels less attractive in routine clinical use. Dose resolution has recently been introduced as a concept for comparing and optimizing the performance of different types of gel dosimeters. This parameter has not yet been investigated for Fricke gels. In this study, the effect on the dose resolution and the diffusion from different gelatine- and Fe2+-concentrations and different pH was evaluated. Increasing the concentration of gelatine from 6 wt% to 10 wt% influenced the diffusion coefficient the most, while reducing the pH from 2.0 to 1.5 had the largest effect on the dose resolution. For a gel consisting of 10 wt% gelatine, 1.0 mM Fe2+ and pH 1.5 the diffusion coefficient was found to be 1.5 mm2 h-1 and the dose resolution was about 4.1% (at 95% confidence level), for a dose of 40 Gy. By evaluating different dose gradients by the gamma-method, the diffusion was shown to have no clinically relevant impact on the dose distribution and plan acceptance within 3 h of irradiation. The results indicate a potential use of Fricke gels for IMRT verification.
Collapse
|
56
|
Gifford KA, Horton JL, Jackson EF, Steger TR, Heard MP, Mourtada F, Lawyer AA, Ibbott GS. Comparison of Monte Carlo calculations around a Fletcher Suit Delclos ovoid with radiochromic film and normoxic polymer gel dosimetry. Med Phys 2005; 32:2288-2294. [PMID: 16121584 DOI: 10.1118/1.1944247] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2004] [Revised: 05/03/2005] [Accepted: 05/04/2005] [Indexed: 11/07/2022] Open
Abstract
The Fletcher Suit Delclos (FSD) ovoids employed in intracavitary brachytherapy (ICB) for cervical cancer contain shields to reduce dose to the bladder and rectum. Many treatment planning systems (TPS) do not include the shields and other ovoid structures in the dose calculation. Instead, TPSs calculate dose by summing the dose contributions from the individual sources and ignoring ovoid structures such as the shields. The goal of this work was to calculate the dose distribution with Monte Carlo around a Selectron FSD ovoid and compare these calculations with radiochromic film (RCF) and normoxic polymer gel dosimetry. Monte Carlo calculations were performed with MCNPX 2.5.c for a single Selectron FSD ovoid with and without shields. RCF measurements were performed in a plane parallel to and displaced laterally 1.25 cm from the long axis of the ovoid. MAGIC gel measurements were performed in a polymethylmethacrylate phantom. RCF and MAGIC gel were irradiated with four 33 microGy m2 h(-1) Cs-137 pellets for a period of 24 h. Results indicated that MCNPX calculated dose to within +/- 2% or 2 mm for 98% of points compared with RCF measurements and to within +/- 3% or 3 mm for 98% of points compared with MAGIC gel measurements. It is concluded that MCNPX 2.5.c can calculate dose accurately in the presence of the ovoid shields, that RCF and MAGIC gel can demonstrate the effect of ovoid shields on the dose distribution and the ovoid shields reduce the dose by as much as 50%.
Collapse
|
57
|
de Jong JJD, Tiemersma-Wegman TD, van Esch JH, Feringa BL. Dynamic Chiral Selection and Amplification Using Photoresponsive Organogelators. J Am Chem Soc 2005; 127:13804-5. [PMID: 16201797 DOI: 10.1021/ja055268a] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The ability to select, amplify, and lock dynamic equilibria is of great interest into understanding and applying chiral systems in Nature. The dynamic equilibrium between P and M helicity of a nonchiral diarylethene switch 3 could selectively be coaggregated in the gel state by complementary chiral switches 1 and 2 (that itself is also subjected to the same equilibrium between P and M helicity). Enantiomeric excess as high as 94% was observed during this dual task for 1 and 2 (arranging itself and 3 in only one conformation during aggregation). Interestingly, opposite chiral induction was observed, although the conformation of both 1 and 2 is R.
Collapse
|
58
|
Trapp JV, Leach MO, Webb S. Preliminary dose response study of a gel dosimeter using 2-Hydroxyethyl Methacrylate (HEMA). ACTA ACUST UNITED AC 2005; 28:172-4. [PMID: 16250471 DOI: 10.1007/bf03178711] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
In this work we present a gel dosimeter based on 2-Hydroxyethyl Methacrylate (HEMA). The gel dosimeter is manufactured in normal atmospheric oxygen (normoxic) and undergoes a measurable change after irradiation. The gel is shown to provide a signal to noise ratio of up to at least 35 and have a linear change in transverse relaxation rate up to 70 Gy when measured with magnetic resonance imaging.
Collapse
|
59
|
Venning AJ, Mather ML, Baldock C. Investigation of vacuum pumping on the dose response of the MAGAS normoxic polymer gel dosimeter. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2005; 28:105-10. [PMID: 16060316 DOI: 10.1007/bf03178700] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The effect of vacuum pumping on the dose response of the MAGAS polymer gel dosimeter has been investigated. A delay of several days post-manufacture before irradiation was previously necessary due to the slow oxygen scavenging of ascorbic acid. The MAGAS polymer gel dosimeter was vacuum pumped before gelation to remove dissolved oxygen. The MAGAS polymer gel dosimeter was poured into glass screw-top vials, which were irradiated at various times, post-manufacture to a range of doses. Magnetic resonance imaging techniques were used to determine the R2-dose response and R2-dose sensitivity of the MAGAS polymer gel. The results were compared with a control batch of MAGAS polymer gel that was not vacuum pumped. It was shown that vacuum pumping on the MAGAS polymer gel solution immediately prior to sealing in glass screw-top vials initially increases the R2-dose response and R2-dose sensitivity of the dosimeter. An increase in the R2-dose response and R2-dose sensitivity was observed with increasing time between manufacture and irradiation. Over the range of post-manufacture irradiation times investigated, the greatest R2-dose response and R2-dose sensitivity occurred at 96 hours.
Collapse
|
60
|
van Doom T, Bhat M, Rutten TP, Tran T, Costanzo A. A fast, high spatial resolution optical tomographic scanner for measurement of absorption in gel dosimetry. ACTA ACUST UNITED AC 2005; 28:76-85. [PMID: 16060313 DOI: 10.1007/bf03178697] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
A fast tomographic optical density measurement system has been constructed and evaluated for application in Fricke 3D gel dosimetry. Although the potential for full three-dimensional radiation dosimetry with Fricke gel dosimeters has been extensively reported, its application has been limited due to a lack of fast optical density measurement systems. In this work, the emphasis of the design has been to achieve a short scan time through the use of precision optics and minimal moving parts. The system has been demonstrated in the laboratory to be able to achieve better than 1mm resolution and a scanning time per tomographic slice of 2.4 seconds. Full volumetric sampling of a 10 cm diameter by 7cm long cylinder can be achieved in 3 minutes. When applied with a Fricke based gel dosimeter a linear response between reconstructed CT number and absolute dose was better than 3%.
Collapse
|
61
|
MacDougall ND, Miquel ME, Wilson DJ, Keevil SF, Smith MA. Evaluation of the dosimetric performance of BANG3® polymer gel. Phys Med Biol 2005; 50:1717-26. [PMID: 15815092 DOI: 10.1088/0031-9155/50/8/007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
New radiotherapy techniques call for three-dimensional dosimetric methods with high spatial resolution. Radiation sensitive gels read out using MRI T(2) mapping provide an extremely promising option, and commercially available BANG polymer gels provide a convenient route into gel dosimetry. Gel dosimetry is dependent on the ability to calibrate gel response against radiation dose. This in turn is dependent on the reproducibility of response both between gels irradiated to the same dose and for a single gel sample over time. This study aims to evaluate the performance of a commercially available BANG gel. Our experimental arrangement gave excellent precision of radiation delivery (<0.2%) and reproducibility of T(2) measurement (<0.5%). Seven groups of 10 test tubes containing BANG3 gel were irradiated in 0.5 Gy steps between 0 and 3 Gy. A further four groups of four samples were irradiated in 2 Gy steps between 4 and 10 Gy. The gel samples were identical and derived from the same manufacturing batch. MR imaging was carried out four days after irradiation and then at weekly intervals for four weeks. Short-term variation in gel response can readily be corrected using reference samples. Longer term systematic drift of the gel calibration curve was observed relative to reference samples prepared in-house for quality assurance purposes. This implies that read-out of the calibration gels and dosimetry phantom must be performed at the same time after irradiation, or errors of up to 25% may be incurred. Precision of gel response did not change significantly over time. The observation of significantly different T(2) values both prior to irradiation and following irradiation to the same dose (variation up to 15%) illustrates the current difficulties associated with BANG3 gel calibration and constrains the practical utility of these commercially available gels for clinical radiation dosimetry.
Collapse
|
62
|
Brindha S, Venning AJ, Hill B, Baldock C. Experimental study of attenuation properties of normoxic polymer gel dosimeters. Phys Med Biol 2005; 49:N353-61. [PMID: 15566179 DOI: 10.1088/0031-9155/49/20/n01] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The change in linear attenuation coefficient with absorbed dose has been investigated for aqueous polyacrylamide, gelatine and tetrakis (PAGAT) and aqueous methacrylic acid, gelatine and tetrakis (MAGAT) normoxic polymer gel dosimeters using tetrakis (hydroxy methyl) phosphonium chloride as the antioxidant. The measured linear attenuation coefficient increased linearly with absorbed dose up to 15 Gy for PAGAT gels and 10 Gy for MAGAT gels. Computerized tomography (CT) numbers or Hounsfield units (H) were calculated from the linear attenuation coefficients and compared with values obtained using a CT scanner. Both calculated and measured CT numbers followed a similar pattern when fitted with a biexponential curve. The CT numbers obtained from linear attenuation measurements were found to be greater than that obtained with the CT scanner for both PAGAT and MAGAT polymer gels. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters measured on a CT scanner were calculated to be (0.85 +/- 0.08) H Gy(-1) and (0.31 +/- 0.03) H Gy(-1), respectively. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters from attenuation measurements were found to be (1.10 +/- 0.66) H Gy(-1) and (0.34 +/- 0.01) H Gy(-1), respectively.
Collapse
|
63
|
Karaiskos P, Petrokokkinos L, Tatsis E, Angelopoulos A, Baras P, Kozicki M, Papagiannis P, Rosiak JM, Sakelliou L, Sandilos P, Vlachos L. Dose verification of single shot gamma knife applications using VIPAR polymer gel and MRI. Phys Med Biol 2005; 50:1235-50. [PMID: 15798319 DOI: 10.1088/0031-9155/50/6/013] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This work describes an experimental procedure with potential to assess the overall accuracy associated with gamma knife clinical applications, from patient imaging and dosimetry planning to patient positioning and dose delivery using the automated positioning system of a Leksell Gamma Knife model C. The VIPAR polymer gel-MRI dosimetry method is employed due to its inherent three-dimensional feature and linear dose response over the range of gamma knife applications. Different polymer gel vials were irradiated with single shot gamma knife treatment plans using each of the four available collimator helmets to deliver a maximum dose of 30 Gy. Percentage relative dose results are presented not only in the form of one-dimensional profiles but also planar isocontours and isosurfaces in three dimensions. Experimental results are compared with corresponding Gammaplan treatment planning system calculations as well as acceptance test radiochromic film measurements. A good agreement, within the experimental uncertainty, is observed between measured and expected dose distributions. This experimental uncertainty is of the order of one imaging pixel in the MRI gel readout session (<1 mm) and allows for the verification of single shot gamma knife applications in terms of acceptance specifications for precision in beam alignment and accuracy. Averaging net R(2) results in the dose plateau of the 4 mm and 18 mm collimator irradiated gel vials, which were MR scanned in the same session, provides a crude estimate of the 4 mm output factor which agrees within errors with the default value of 0.870.
Collapse
|
64
|
Anedda A, Carbonaro CM, Clemente F, Corpino R, Ricci PC. Time Resolved Ultraviolet Photoluminescence of Mesoporous Silica. J Phys Chem B 2004; 109:1239-42. [PMID: 16851086 DOI: 10.1021/jp0471397] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We studied the optical properties of sol-gel synthesized porous silica excited by synchrotron radiation in the 4-10 eV range. The spectral and temporal characteristics of the ultraviolet photoluminescence at about 3.7 eV are reported. The UV emission results from the contribution of two different centers: the first one centered at 3.7 eV with a decay time of 2.0 ns and the second one peaked at 3.9 eV with a decay time of 20 ns. We propose to assign the observed luminescence to different interacting surface silanols.
Collapse
|
65
|
Oldham M, Kim L. Optical-CT gel-dosimetry. II: Optical artifacts and geometrical distortion. Med Phys 2004; 31:1093-104. [PMID: 15191297 PMCID: PMC1592131 DOI: 10.1118/1.1655710] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
There is a clear need for technology that enables accurate, high-resolution, three-dimensional (3D) measurement of intricate dose distributions associated with modern radiation treatments. A potential candidate has emerged in the form of water-equivalent "3D gel dosimetry" utilizing optical-computed-tomography (optical-CT). In a previous paper we presented basic physical characterization of an in-house prototype optical-CT scanning system. The present paper builds on that work by investigating sources of optical artifacts and geometric distortion in optical-CT scanning. Improvements in scanner design are described. Correction strategies were developed to compensate for reflection and refraction, imperfections in the water-bath, signal drift, and other effects. Refraction and reflection were identified as the principal factors causing inaccurate reconstruction of absolute attenuation coefficients. A correction specific to a given flask was developed utilizing prescans of the flask when filled with water-bath fluid, thereby isolating the refractive and reflective components for that flask. Residual artifacts were corrected by fitting a theoretical model to the well-behaved portion of these prescans and extrapolating to regions of lost data, enabling reconstruction of absolute optical-CT attenuation coefficients to within 4% of corresponding spectrophotometer values. Needle phantoms are introduced to quantify geometric distortion under a range of conditions. Radial distortion of reconstructed needle positions was reduced to < 0.3 mm (0.27% of the field of view) through adjustment of the water-bath refractive index. Geometric distortion in polymer gel due to radiation-induced refractive index changes was found to be negligible under the conditions examined. The influence of scattered light on reconstructed attenuation coefficients was investigated by repeat optical-CT scans while varying the aperture of a scatter-rejecting collimator. Significant depression of reconstructed attenuation coefficients was observed, particularly under conditions of poor scatter rejection collimation. The general conclusion is that the first-generation optical-CT technique can be made insensitive to geometrical distortion, but can be susceptible to scatter effects. For accurate reconstruction of absolute attenuation coefficients, correction strategies are essential.
Collapse
|
66
|
Watanabe Y, Mooij R, Perera GM, Maryanski MJ. Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry. Med Phys 2004; 31:975-84. [PMID: 15191281 DOI: 10.1118/1.1688210] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Heterogeneity corrections in dose calculations are necessary for radiation therapy treatment plans. Dosimetric measurements of the heterogeneity effects are hampered if the detectors are large and their radiological characteristics are not equivalent to water. Gel dosimetry can solve these problems. Furthermore, it provides three-dimensional (3D) dose distributions. We used a cylindrical phantom filled with BANG-3 polymer gel to measure 3D dose distributions in heterogeneous media. The phantom has a cavity, in which water-equivalent or bone-like solid blocks can be inserted. The irradiated phantom was scanned with an magnetic resonance imaging (MRI) scanner. Dose distributions were obtained by calibrating the polymer gel for a relationship between the absorbed dose and the spin-spin relaxation rate of the magnetic resistance (MR) signal. To study dose distributions we had to analyze MR imaging artifacts. This was done in three ways: comparison of a measured dose distribution in a simulated homogeneous phantom with a reference dose distribution, comparison of a sagittally scanned image with a sagittal image reconstructed from axially scanned data, and coregistration of MR and computed-tomography images. We found that the MRI artifacts cause a geometrical distortion of less than 2 mm and less than 10% change in the dose around solid inserts. With these limitations in mind we could make some qualitative measurements. Particularly we observed clear differences between the measured dose distributions around an air-gap and around bone-like material for a 6 MV photon beam. In conclusion, the gel dosimetry has the potential to qualitatively characterize the dose distributions near heterogeneities in 3D.
Collapse
|
67
|
Fragoso M, Love PA, Verhaegen F, Nalder C, Bidmead AM, Leach M, Webb S. The dose distribution of low dose rate Cs-137 in intracavitary brachytherapy: comparison of Monte Carlo simulation, treatment planning calculation and polymer gel measurement. Phys Med Biol 2004; 49:5459-74. [PMID: 15724536 DOI: 10.1088/0031-9155/49/24/005] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
In this study, the dose distribution delivered by low dose rate Cs-137 brachytherapy sources was investigated using Monte Carlo (MC) techniques and polymer gel dosimetry. The results obtained were compared with a commercial treatment planning system (TPS). The 20 mm and the 30 mm diameter Selectron vaginal applicator set (Nucletron) were used for this study. A homogeneous and a heterogeneous-with an air cavity-polymer gel phantom was used to measure the dose distribution from these sources. The same geometrical set-up was used for the MC calculations. Beyond the applicator tip, differences in dose as large as 20% were found between the MC and TPS. This is attributed to the presence of stainless steel in the applicator and source set, which are not considered by the TPS calculations. Beyond the air cavity, differences in dose of around 5% were noted, due to the TPS assuming a homogeneous water medium. The polymer gel results were in good agreement with the MC calculations for all the cases investigated.
Collapse
|
68
|
Xu Y, Wuu CS, Maryanski MJ. Performance of a commercial optical CT scanner and polymer gel dosimeters for 3-D dose verification. Med Phys 2004; 31:3024-33. [PMID: 15587656 DOI: 10.1118/1.1803674] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Performance analysis of a commercial three-dimensional (3-D) dose mapping system based on optical CT scanning of polymer gels is presented. The system consists of BANG 3 polymer gels (MGS Research, Inc., Madison, CT), OCTOPUS laser CT scanner (MGS Research, Inc., Madison, CT), and an in-house developed software for optical CT image reconstruction and 3-D dose distribution comparison between the gel, film measurements and the radiation therapy treatment plans. Various sources of image noise (digitization, electronic, optical, and mechanical) generated by the scanner as well as optical uniformity of the polymer gel are analyzed. The performance of the scanner is further evaluated in terms of the reproducibility of the data acquisition process, the uncertainties at different levels of reconstructed optical density per unit length and the effects of scanning parameters. It is demonstrated that for BANG 3 gel phantoms held in cylindrical plastic containers, the relative dose distribution can be reproduced by the scanner with an overall uncertainty of about 3% within approximately 75% of the radius of the container. In regions located closer to the container wall, however, the scanner generates erroneous optical density values that arise from the reflection and refraction of the laser rays at the interface between the gel and the container. The analysis of the accuracy of the polymer gel dosimeter is exemplified by the comparison of the gel/OCT-derived dose distributions with those from film measurements and a commercial treatment planning system (Cadplan, Varian Corporation, Palo Alto, CA) for a 6 cm x 6 cm single field of 6 MV x rays and a 3-D conformal radiotherapy (3DCRT) plan. The gel measurements agree with the treatment plans and the film measurements within the "3%-or-2 mm" criterion throughout the usable, artifact-free central region of the gel volume. Discrepancies among the three data sets are analyzed.
Collapse
|
69
|
Abstract
Phantoms are commonly used in medical imaging for quality assurance, calibration, research and teaching. They may include test patterns or simulations of organs, but in either case a tissue substitute medium is an important component of the phantom. The aim of this work was to identify materials suitable for use as tissue substitutes for the relatively new medical imaging modality terahertz pulsed imaging. Samples of different concentrations of the candidate materials TX151 and napthol green dye were prepared, and measurements made of the frequency-dependent absorption coefficient (0.5 to 1.5 THz) and refractive index (0.5 to 1.0 THz). These results were compared qualitatively with measurements made in a similar way on samples of excised human tissue (skin, adipose tissue and striated muscle). Both materials would be suitable for phantoms where the dominant mechanism to be simulated is absorption (approximately 100 cm(-1) at 1 THz) and where simulation of the strength of reflections from boundaries is not important; for example, test patterns for spatial resolution measurements. Only TX151 had a frequency-dependent refractive index close to that of tissue, and could therefore be used to simulate the layered structure of skin, the complexity of microvasculature or to investigate frequency-dependent interference effects that have been noted in terahertz images.
Collapse
|
70
|
Vergote K, De Deene Y, Vanden Bussche E, De Wagter C. On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters. Phys Med Biol 2004; 49:4507-22. [PMID: 15552414 DOI: 10.1088/0031-9155/49/19/005] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
When irradiating a polymer gel dosimeter to relatively high doses, edge enhancing effects (overshoots) may be noticed near dose gradients, resulting in a loss of spatial dose integrity. These overshoots are believed to be a consequence of monomers diffusing into the high-dose region, where they react with long-living macroradicals. Macroradicals may also be responsible for the temporal chemical instability of post-irradiation polymerization that occurs in the polymer gel dosimeter. In this study, a mathematical model is proposed that simulates the edge enhancing effect. The model is based on the hypothesis that the macroradicals are responsible for both the temporal instability and loss of spatial dose integrity. All input parameters for the model are obtained from independent experiments. The edge enhancing effect is studied both experimentally and theoretically for polymer gel dosimeters with various gelatin concentrations. The change in the edge enhancement is also investigated over post-irradiation time. Comparisons between polymer gel measurements and simulations confirm the hypothesis that there is a strong relation between the spatial and temporal instabilities.
Collapse
|
71
|
Trapp JV, Warrington AP, Partridge M, Philps A, Glees J, Tait D, Ahmed R, Leach MO, Webb S. Measurement of the three-dimensional distribution of radiation dose in grid therapy. Phys Med Biol 2004; 49:N317-23. [PMID: 15552424 DOI: 10.1088/0031-9155/49/19/n01] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A single large dose of megavoltage x-rays delivered through a grid is currently being utilized by some centres for palliative radiotherapy treatments of large tumours. In this note, we investigate the dosimetry of grid therapy using two-dimensional film dosimetry and three-dimensional gel dosimetry. It is shown that the radiation dose is attenuated more rapidly with depth in a grid field than an open field, and that even shielded regions receive approximately 25% of the dose to the unshielded areas.
Collapse
|
72
|
Pantelis E, Karlis AK, Kozicki M, Papagiannis P, Sakelliou L, Rosiak JM. Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy. Phys Med Biol 2004; 49:3495-514. [PMID: 15379028 DOI: 10.1088/0031-9155/49/15/013] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The water equivalence and stable relative energy response of polymer gel dosimeters are usually taken for granted in the relatively high x-ray energy range of external beam radiotherapy based on qualitative indices such as mass and electron density and effective atomic number. However, these favourable dosimetric characteristics are questionable in the energy range of interest to brachytherapy especially in the case of lower energy photon sources such as 103Pd and 125I that are currently utilized. In this work, six representative polymer gel formulations as well as the most commonly used experimental set-up of a LiF TLD detector-solid water phantom are discussed on the basis of mass attenuation and energy absorption coefficients calculated in the energy range of 10 keV-10 MeV with regard to their water equivalence as a phantom and detector material. The discussion is also supported by Monte Carlo simulation results. It is found that water equivalence of polymer gel dosimeters is sustained for photon energies down to about 60 keV and no corrections are needed for polymer gel dosimetry of 169Yb or 192Ir sources. For 125I and 103Pd sources, however, a correction that is source-distance dependent is required. Appropriate Monte Carlo results show that at the dosimetric reference distance of 1 cm from a source, these corrections are of the order of 3% for 125I and 2% for 103Pd. These have to be compared with corresponding corrections of up to 35% for 125I and 103Pd and up to 15% even for the 169Yb energies for the experimental set-up of the LiF TLD detector-solid water phantom.
Collapse
|
73
|
Hurley C, De Deene Y, Meder R, Pope JM, Baldock C. The effect of water molecular self-diffusion on quantitative high-resolution MRI polymer gel dosimetry. Phys Med Biol 2004; 48:3043-58. [PMID: 14529209 DOI: 10.1088/0031-9155/48/18/306] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In polymer gel dosimetry, magnetic resonance imaging (MRI) is used to determine the spin-spin relaxation rate (R2) which in turn can be correlated with absorbed dose to provide a map of the spatial distribution of the absorbed dose in the irradiated dosimeter. High accuracy, precision and reproducibility of these dose maps are essential. Moreover, for dose verification around brachytherapy sources used for intravascular brachytherapy, a high spatial resolution is required (typically 0.01-0.1 mm). To achieve these microscopic resolutions, strong imaging gradients are applied. The Brownian motion of water molecules in the presence of these strong magnetic field gradients causes an attenuation of the MR signal. When using a multiple spin-echo sequence, this may result in a significant deviation in the measured R2. The diffusion-related change in R2 at high resolutions was investigated experimentally and correlated with predictions that were obtained numerically and algebraically. Diffusion weighting is determined by the self-diffusion coefficient D, and imaging parameters, quantified by the b-factor. The b-factor was calculated for a multiple spin-echo sequence for different gradient strengths and gradient pulse durations. The variations in R2 that were observed when changing the matrix size and slice thickness are explained. It is shown that a linear correlation between the matrix size and the variation in R2 is based on the diffusion weighting caused by the read-out gradients and slice selective gradients. In conclusion, the essence of taking into account molecular self-diffusion to quantify variations in the measured dose-R2 response when using high-resolution MRI in polymer gel dosimetry is emphasized.
Collapse
|
74
|
Ko DS. Photobleaching time distribution of a single tetramethylrhodamine molecule in agarose gel. J Chem Phys 2004; 120:2530-1. [PMID: 15268396 DOI: 10.1063/1.1636726] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
75
|
Healy BJ, Zahmatkesh MH, Nitschke KN, Baldock C. Effect of saccharide additives on response of ferrous-agarose-xylenol orange radiotherapy gel dosimeters. Med Phys 2003; 30:2282-91. [PMID: 14528948 DOI: 10.1118/1.1597771] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Glucose, sucrose, starch, and locust bean gum have been used as additives to the ferrous-agarose-xylenol orange (FAX) gel dosimeter. The saccharide enhanced dosimeters were found to have a higher dose sensitivity over a standard FAX gel as measured by both optical density change and magnetic resonance imaging (MRI). With optical density measurement, OD-dose sensitivity increases were up to 55% for glucose, 122% for sucrose and 43% for starch, while locust bean gum did not give a consistent response. With MRI, R1-dose sensitivity increases were up to 178% with sucrose addition. The FAX gel with sucrose was studied in greatest detail. The OD-dose sensitivity dependence on cooling rate was reduced for the sucrose FAX gel over the standard FAX gel, which has significant implications for uniform dose sensitivity in large gel phantoms. The thermal oxidation rate in the sucrose FAX gel was up to 2.3 times higher than in the standard gel. The OD-dose sensitivity of oxygenated sucrose FAX gels was 4.3 times greater than standard FAX gels, while continued enhancement in OD-dose sensitivity with increased sucrose concentrations beyond 2.0 g/l was found only for the oxygenated sucrose FAX gels. Both the molar absorption coefficient of the ferric ion-xylenol orange complex at 543 nm and gel pH were not affected by the presence of sucrose, with the implication that the higher OD-dose sensitivity of gels with saccharides is due to increased chain reaction production of ferric ions.
Collapse
|
76
|
Fournier C, Brons S, Taucher-Scholz G. Quantification of chemiluminescent signals using photon-sensitive films or a CCD camera. Biotechniques 2003; 35:284-90. [PMID: 12951769 DOI: 10.2144/03352bi01] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
77
|
Heufelder J, Stiefel S, Pfaender M, Lüdemann L, Grebe G, Heese J. Use of BANG polymer gel for dose measurements in a 68 MeV proton beam. Med Phys 2003; 30:1235-40. [PMID: 12852548 DOI: 10.1118/1.1575557] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
BANG polymer gel dosimetry using magnetic resonance imaging (MRI) was applied to an ophthalmologic 68 MeV proton beam. The object was to examine the use of BANG gel for the verification of proton fields in eye tumor therapy and to explore the applicability of polymer gel dosimetry in proton therapy under practical aspects. The gel phantoms were irradiated with monoenergetic and modulated proton beams. MRI analysis was carried out at clinical 1.5 and 3 T MR scanners. At constant LET, results show a linear relationship between spin-spin relaxation rates and dose. However, depth dose curves in BANG gel reveal a quenching of the Bragg maximum due to LET effects. The dose response of the gel for monoenergetic protons and spread-out depth dose distributions can be calculated based on ionization chamber measurements. Experiment and calculations show good agreement and indicate that BANG polymer gels might become a valuable tool in proton therapy quality assurance.
Collapse
|
78
|
Vergote K, De Deene Y, Claus F, De Gersem W, Van Duyse B, Paelinck L, Achten E, De Neve W, De Wagter C. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions. Radiother Oncol 2003; 67:119-28. [PMID: 12758248 DOI: 10.1016/s0167-8140(02)00376-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND AND PURPOSE When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. MATERIALS AND METHODS The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. RESULTS Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. CONCLUSIONS For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations.
Collapse
|
79
|
Oldham M, Siewerdsen JH, Kumar S, Wong J, Jaffray DA. Optical-CT gel-dosimetry I: basic investigations. Med Phys 2003; 30:623-34. [PMID: 12722814 PMCID: PMC1616153 DOI: 10.1118/1.1559835] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Comprehensive verification of the intricate dose distributions associated with advanced radiation treatments is now an immediate and substantial problem. The task is challenging using traditional dosimeters because of restrictions to point measurements (ion chambers, diodes, TLD, etc.) or planar measurements (film). In essence, rapid advances in the technology to deliver radiation treatments have not been paralleled by corresponding advances in the ability to verify these treatments. A potential solution has emerged in the form of water equivalent three dimensional (3D) gel-dosimetry. In this paper we present basic characterization and performance studies of a prototype optical-CT scanning system developed in our laboratory. An analysis of the potential role or scope of gel dosimetry, in relation to other dosimeters, and to verification across the spectrum of therapeutic techniques is also given. The characterization studies enabled the determination of nominal operating conditions for optical-CT scanning. "Finger" phantoms are introduced as a powerful and flexible tool for the investigation of optical-CT performance. The modulation-transfer function (MTF) of the system is determined to be better than 10% out to 1 mm(-1), confirming sub-mm imaging ability. System performance is demonstrated by the acquisition of a 1 x 1 x 1 mm3 dataset through the dose distribution delivered by an x-ray lens that focuses x rays in the energy range 40-80 KeV. This 3D measurement would be extremely difficult to achieve with other dosimetry techniques and highlights some of the strengths of gel dosimetry. Finally, an optical Monte Carlo model is introduced and shown to have potential to model light transport through gel-dosimetry systems, and to provide a tool for the study and optimization of optical-CT gel dosimetry. The model utilizes Mie scattering theory and requires knowledge of the variation of the particle size distribution with dose. The latter was determined here using the technique of dynamic-light-scattering.
Collapse
|
80
|
Pappas E, Angelopoulos A, Kipouros P, Vlachos L, Xenofos S, Seimenis I. Evaluation of the performance of VIPAR polymer gels using a variety of x-ray and electron beams. Phys Med Biol 2003; 48:N65-73. [PMID: 12696803 DOI: 10.1088/0031-9155/48/5/401] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The aim of this investigation was the evaluation of the usefulness of N-vinyl pyrrolidone argon (VIPAR) polymer gel dosimetry for relative dose measurements using the majority of types and energies of radiation beams used in clinical practice. For this reason, VIPAR polymer gels were irradiated with the following beams: 6 and 23 MV photons (maximum dose: 15 Gy) and 6, 9, 12, 15, 18 and 21 MeV electrons (90% dose: 15 Gy). Using 6 MV x-rays, a linear gel dose response was verified for doses up to 20 Gy. Assuming linearity of response for the rest of the photon and electron beams used in this study, percentage depth dose measurements were derived. For all beams used and the range of relative doses studied, a satisfying agreement was observed between percentage depth dose measurements performed using the VIPAR gel-MRI method and an ion chamber, validating the assumption that a linear gel dose response holds for all photon and electron beams studied. VIPAR gels, therefore, can be used for relative dose distribution measurements using photons or electrons of any typical energy used in external radiotherapy applications. It is also demonstrated that two-dimensional dose distribution measurements through an irradiated (9 MeV electrons, 3 cm x 3 cm cone) VIPAR gel volume can be easily obtained.
Collapse
|
81
|
MacDougall ND, Pitchford WG, Smith MA. Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry''. Phys Med Biol 2003; 48:L19-22. [PMID: 12630749 DOI: 10.1088/0031-9155/48/4/101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
82
|
De Deene Y, De Wagter C, Baldock C. Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and fricke MRI gel dosimetry'. Phys Med Biol 2003; 48:L15-8. [PMID: 12608618 DOI: 10.1088/0031-9155/48/3/101] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
83
|
Silva NA, Nicolucci P, Baffa O. Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom. Med Phys 2003; 30:17-20. [PMID: 12557973 DOI: 10.1118/1.1527039] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The spatial accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry is limited by diffusion of ferric ions. This paper describes a honeycomb structure to limit diffusion of Fe3+ ions in a three-dimensional phantom. Such a phantom containing the dosimeter gel was irradiated to a known dose distribution. Maps of dose distributions were produced from the MR images acquired at 2 and 24 hours after the dose was given. The dose distribution maps verified that the honeycomb structure precludes ion diffusion from one honeycomb cell to another, thus improving the usefulness of MRI Fricke-gel dosimetry.
Collapse
|
84
|
Rintoul L, Lepage M, Baldock C. Radiation dose distribution in polymer gels by Raman spectroscopy. APPLIED SPECTROSCOPY 2003; 57:51-57. [PMID: 14610936 DOI: 10.1366/000370203321165205] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The Raman spectroscopy of polymer gel dosimeters has been investigated with a view to developing a novel dosimetry technique that is capable of determining radiation dose within a micrometer of spatial resolution. The polymer gel dosimeter, known as the PAG dosimeter, is typically made up of acrylamide, N,N'-methylene-bis--acrylamide, gelatin, and water. A polyacrylamide network within the gelatin matrix forms in response to an absorbed dose. The loss of monomers may be monitored by corresponding changes to the Raman spectrum. Principal component analysis offers a simple method of quantifying the absorbed radiation dose from the Raman spectrum of the polymer gel. The background luminescence in the spectrum increased significantly with dose and is shown to originate in the glass of the sample vial. The competing effects of elastic scatter, which increases with dose due to the formation of polymer, and sample absorption were quantified and found to introduce errors of up to 5% under certain conditions. Raman spectra as a function of distance from the air-surface interface have been measured for samples that were subjected to doses delivered by a clinical linear accelerator. The depth dose profile thus obtained compared favorably with "gold standard" ion-chamber measurements.
Collapse
|
85
|
Mather ML, De Deene Y, Whittaker AK, Simon GP, Rutgers R, Baldock C. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters. Phys Med Biol 2002; 47:4397-409. [PMID: 12539980 DOI: 10.1088/0031-9155/47/24/307] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.
Collapse
|
86
|
Nyirady J, Lucas C, Yusuf M, Mignone P, Wisniewski S. The stability of tretinoin in tretinoin gel microsphere 0.1%. Cutis 2002; 70:295-8. [PMID: 12469785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
Abstract
Topical tretinoin is highly effective and widely used in the treatment of acne vulgaris. In studies to determine the degree of tretinoin photo degradation (isomerization), 2 tretinoin formulations, tretinoin gel microsphere 0.1% and tretinoin gel 0.025%, alone or in combination with erythromycin-benzoyl peroxide topical gel, were exposed to fluorescent light, incandescent light, or darkness for up to 24 hours. Results of the investigations revealed that after 24 hours of exposure to fluorescent light, 98% of the initial tretinoin in the tretinoin gel microsphere 0.1% formulation remained unchanged. When tretinoin gel microsphere 0.1% was combined with erythromycin-benzoyl peroxide topical gel and exposed to fluorescent light, 99% and 87% of the tretinoin was recovered after 4 and 24 hours, respectively, indicating only a limited amount of degradation. In contrast, exposure of tretinoin gel 0.025% to 24 hours of fluorescent light resulted in up to 69% tretinoin degradation and up to 89% degradation when the gel was combined with the erythromycin-benzoyl peroxide topical gel. The data suggest that the tretinoin gel microsphere 0.1% formulation offers marked protection against tretinoin photo degradation, even in the presence of a strong oxidizing agent such as benzoyl peroxide.
Collapse
|
87
|
Cehreli MC, Canay S. Comparison of post-gel shrinkage strains in light-polymerized composite resins. J Prosthet Dent 2002; 88:461-6. [PMID: 12473993 DOI: 10.1067/mpr.2002.129080] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM Polymerization shrinkage is associated with light-polymerized and polyacid-modified composites. PURPOSE This in vitro study compared the polymerization shrinkage of a light-polymerized hybrid composite, a posterior composite, and a polyacid-modified composite. MATERIAL AND METHODS Five disk-shaped specimens (1 cm in diameter and 2 mm in thickness) were prepared in a mold from each of the following test materials: a light-polymerized hybrid composite (3M Valux Plus), a posterior composite (Filtek P60), and a polyacid-modified composite (Dyract AP). The hybrid composite served as the control material. A linear strain gauge was placed at the center of each specimen. After the specimens were light-polymerized for 60 seconds under 400-mW/cm(2) light intensity, microstrains were recorded with the strain indicator continuously every 4 seconds for 120 seconds. The data were evaluated with 1-way analysis of variance (P<.05) followed by a post hoc least significant difference test. RESULTS During the first 20 seconds of light polymerization, all materials exhibited tensile strains between 6 and 55 mu epsilon that quickly converted into compressive strains and continued rising after the light source was removed. The strains for all materials increased at a declining rate until they reached a constant level between 148 and 180 seconds. The polymerization shrinkage recorded for Filtek P60 was the lowest (-190.56 mu epsilon), followed by 3M Valux Plus (-303.94 mu epsilon) and Dyract AP (-345.64 mu epsilon) (P<.05). The dimensional change between Filtek P60 and Dyract AP and between Filtek P60 and 3M Valux Plus was significant (P=.001). However, the difference between Dyract AP and 3M Valux Plus specimens was not significant (P=.208). CONCLUSION Within the limitations of this study, the light-polymerized posterior composite tested demonstrated less polymerization shrinkage than the polyacid-modified and hybrid composites tested. Polymerization shrinkage velocity significantly affected the magnitude of strains.
Collapse
|
88
|
MacDougall ND, Pitchford WG, Smith MA. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry. Phys Med Biol 2002; 47:R107-21. [PMID: 12433119 DOI: 10.1088/0031-9155/47/20/201] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-51)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al 1998 Radiother: Oncol. 48 283-91, Farajollahi et al 2000 Br. J. Radiol. 72 1085-92, McJury et al 1999b Phys. Med. Biol. 44 2431-44, Murphy et al 2000b Phys. Med. Biol. 45 835-45, Oldham et al 2001 Med. Phys. 28 1436-45) and 5% for Fricke gel (Chan and Ayyangar 1995b Med. Phys. 22 1171-5). Evidence also points to accuracy worsening at lower dose levels for both gels. The precision data should be viewed with caution as repeated MR measurements were not performed with the same samples. The only precision data for Fricke gels was 1.5% (Johansson Back et al 1998 Phys. Med. Biol. 43 261-76), but for zero dose. In conclusion, despite the amount of published data, sparse research has been undertaken which provides clear evidence of the accuracy and precision for both gels. That which has been published has used higher doses than would be routine in radiotherapy. The basic radiation dosimeter qualities of accuracy and precision have yet to be fully quantified for polymer and Fricke gels at clinically relevant dose levels.
Collapse
|
89
|
Abstract
The overall performance of polymer gel dosimeters for three-dimensional radiation dosimetry is determined by the temporal and spatial stability of the gels, dose sensitivity and image quality with respect to both systematic and stochastic deviations. The dose resolution (D(p)delta) is determined by the dose sensitivity and the signal-to-noise ratio (SNR) in the dose images. The dose sensitivity can be altered by changing the chemical composition of the polymer gel. The SNR is determined by the scanner and the imaging sequence. In the dose verification of conformal radiotherapy treatments the chosen number of slices may reach a number of 10-20. For these experiments, to obtain a sufficient SNR within a reasonable measurement time using a certain MR scanner, the imaging sequence should be optimized. A few other studies have emphasized the importance of optimizing the imaging sequence with respect to dose resolution (D(p)delta) or SNR but do not give quantitative values for the optimal sequence parameters for scanning a polymer gel dosimeter in three dimensions. In this paper, it is proved that a multiple spin-echo sequence is preferable to a single spin-echo sequence. It is also shown that when using a multiple spin-echo sequence it is not the inter-echo time that should be optimized but the number of echoes. An algebraical expression is derived for the dose resolution in terms of sequence parameters. A mathematical formalism and look-up tables are provided that can be used to optimize both a single and a slice-selective multiple spin-echo sequence to acquire a set of dose images at various locations. The use of the optimization protocol is illustrated by some examples. The optimization protocol enables the user to derive the optimal sequence parameters to acquire a set of dose maps obtained by quantitative T2 imaging for each polymer gel dosimeter within the shortest time possible.
Collapse
|
90
|
De Deene Y, Venning A, Hurley C, Healy BJ, Baldock C. Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. Phys Med Biol 2002; 47:2459-70. [PMID: 12171334 DOI: 10.1088/0031-9155/47/14/307] [Citation(s) in RCA: 125] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In this study the stability of different polymer gel dosimeters is investigated. Further to a previous chemical stability study on a (6%T, 50%C) PAG gel, the change in slope and intercept of the linear part of the R2-dose plot is recorded with time for different gel formulations. In addition to this R2-dose-response stability study, the dose edge of a half-blocked field was recorded with time. Three different PAG type polymer gels, a hydroxyethyl acrylate (HEA) gel and two different normoxic polymer gels were investigated. In the PAG type polymer gels, the relative concentration of gelatin and comonomers was varied in order to study the influence of the different components, that constitute the dosimeter, on the stability. It is shown that the R2-dose-response stability is largely determined by the chemical composition of the gel dosimeters. All the PAG gel dosimeters and the normoxic gel dosimeters are found to preserve the integrity of the dose distribution up to 22 days after irradiation. The half-life of the change in dose sensitivity of a MAGIC gel is found to be 18 h compared to 5.7 h for a (6%T, 50%C) PAG gel. A maximum relative decrease in dose sensitivity of 21% was noted for the MAGIC gel compared to an increase of 50% for a (6%T, 50%C) PAG gel. A loss of integrity of the dose distribution was found in the HEA gel.
Collapse
|
91
|
Keller PF, Verin V, Ziegler T, Mermillod B, Popowski Y, Delafontaine P. Gamma-Irradiation Markedly Inhibits the Hydrated Collagen Gel Contraction by Arterial Smooth Muscle Cells. J Investig Med 2001; 49:258-64. [PMID: 11352183 DOI: 10.2310/6650.2001.33970] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Vessel wall responses to percutaneous transluminal coronary angioplasty include neointimal proliferation and arterial remodeling. The contraction of a collagen gel is a good in vitro model of wound repair and vascular remodeling. Because irradiation is an important new therapeutic modality capable of preventing restenosis, the purpose of this study was to evaluate the effect of irradiation on the contraction of a collagen gel by smooth muscle cells (SMCs), on SMCs viability, and on DNA synthesis. METHODS We studied the effect of different doses of gamma-irradiation (0 [control], 6, 12, and 18 Gy) on the contraction of a collagen gel seeded with SMCs (calf carotid arteries) during a period of 15 days. RESULTS Maximal gel diameter reduction (from 35 to 6.8 mm, +/-0.5 mm in control) was markedly inhibited in the 6-, 12-, and 18-Gy groups (35 to 13.7 mm, +/-0.8 mm; 35 to 15.5 mm, +/-0.9 mm; and 35 to 16.1 mm, +/-0.9 mm, respectively; P<0.0001). The irradiated gels showed a dose-dependent reduction in the SMC proliferation rate (P<0.0001) and an increase in the number of nonviable SMCs (P<0.002) 15 days after irradiation. CONCLUSIONS Gamma-irradiation produces a significant dose-dependent inhibition of the contraction of collagen gels seeded with arterial SMCs. This effect is related to a significant decrease in SMC viability and a decrease in SMC proliferation rate. These findings shed light on mechanisms whereby irradiation may positively affect arterial remodeling after percutaneous transluminal coronary angioplasties.
Collapse
|
92
|
Olberg S, Skretting A, Bruland O, Olsen DR. Dose distribution measurements by MRI of a phantom containing lung tissue equivalent compartments made of ferrous sulphate gel. Phys Med Biol 2000; 45:2761-70. [PMID: 11049170 DOI: 10.1088/0031-9155/45/10/303] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Gel dosimetry based on magnetic resonance imaging (MRI) has previously been shown to provide verification of calculated dose distributions in soft tissue equivalent homogeneous phantoms. This study demonstrates how measurements of dose distribution can also be achieved in a phantom containing porous, lung-equivalent, Fricke gel. A phantom was made of Fe2+ infused low-density gel and conventional ferrous sulphate gel, filled in separate compartments in a Perspex container. Absorbed dose measurements were accomplished by MR imaging and by calibrating the proton spin-lattice relaxation rate (R1) versus absorbed dose by means of TLD measurements. This study shows that the production of lung-equivalent low-density (LD) dosimeter gel (mean CT number of -610 HU) is feasible. The MR signal detected in the LD gel dosimeter was substantially more noisy (i.e. displayed larger random fluctuations) than the signal from conventional gel, as expected. A deviation between calculated (TPS) and measured dose of about 3% (6 MV) and 4-7% (15 MV) was found in the LD region of the phantom. These results correspond well with data from other studies of dose distribution in lung-equivalent phantoms. The Fe2+ infused LD gel therefore seems suitable for measurement of absorbed dose distribution in phantoms that contain lung tissue compartments.
Collapse
|
93
|
de Pasquale F, Sebastiani G, Egger E, Guidoni L, Luciani AM, Marzola P, Manfredi R, Pacilio M, Piermattei A, Viti V, Barone P. Bayesian estimation of relaxation times T(1) in MR images of irradiated Fricke-agarose gels. Magn Reson Imaging 2000; 18:721-31. [PMID: 10930782 DOI: 10.1016/s0730-725x(00)00149-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The authors present a novel method for processing T(1)-weighted images acquired with Inversion-Recovery (IR) sequence. The method, developed within the Bayesian framework, takes into account a priori knowledge about the spatial regularity of the parameters to be estimated. Inference is drawn by means of Markov Chains Monte Carlo algorithms. The method has been applied to the processing of IR images from irradiated Fricke-agarose gels, proposed in the past as relative dosimeter to verify radiotherapeutic treatment planning systems. Comparison with results obtained from a standard approach shows that signal-to noise ratio (SNR) is strongly enhanced when the estimation of the longitudinal relaxation rate (R1) is performed with the newly proposed statistical approach. Furthermore, the method allows the use of more complex models of the signal. Finally, an appreciable reduction of total acquisition time can be obtained due to the possibility of using a reduced number of images. The method can also be applied to T(1) mapping of other systems.
Collapse
|
94
|
Ertl A, Berg A, Zehetmayer M, Frigo P. High-resolution dose profile studies based on MR imaging with polymer BANG(TM) gels in stereotactic radiation techniques. Magn Reson Imaging 2000; 18:343-9. [PMID: 10745144 DOI: 10.1016/s0730-725x(99)00131-9] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
High-resolution dose profiles produced by the Leksell Gamma Knife were obtained in BANG(TM) polymer gel, using a 3 T whole-body scanner upgraded by a magnetic resonance microscopy unit. The gel was contained in 22.3 mm diameter flasks that were inserted into a solid, tissue-equivalent head phantom irradiated by fields of by 8 and 14 mm collimators. Dose profiles were obtained from a linear dose-response curve (R(2) vs. Dose). Excellent agreement was obtained when the gel data were compared to film dosimetry and calculated data.
Collapse
|
95
|
Farajollahi AR, Bonnett DE, Ratcliffe AJ, Aukett RJ, Mills JA. An investigation into the use of polymer gel dosimetry in low dose rate brachytherapy. Br J Radiol 1999; 72:1085-92. [PMID: 10700826 DOI: 10.1259/bjr.72.863.10700826] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
An investigation has been carried out into the properties of the BANG polymer gel and its use in the dosimetry of low dose rate brachytherapy. It was discovered that the response of the gel was reproducible and linear to 10 Gy. The gel was found to be tissue equivalent with a response independent of energy to within experimental accuracy (standard error of measurement +/- 5%). The slope of the calibration curve was found to increase from 0.28 +/- 0.01 s-1 Gy-1 to 0.50 +/- 0.02 s-1 Gy-1 for an increase in monomer concentration from 6 to 9%. Absorbed dose distributions for a straight applicator containing 36 137Cs sources were measured using the gel and the results compared with measurements made with thermoluminescent dosemeters (TLDs) and calculated values. Good agreement was found for the relative measurements. The root mean square residual percentage errors were 3%, 1% and 4% for the gel and the two groups of TLDs, respectively. There were some significant differences in absolute values of absorbed dose in the gel, possibly owing to the effects of oxygen. Measurements of a complex gynaecological insert were also made and compared with isodose curves from a planning system (Helax TMS), and in areas unaffected by oxygen diffusion the isodose levels from 100 to 50% agreed to within less than 0.5 mm.
Collapse
|
96
|
Bäck SA, Medin J, Magnusson P, Olsson P, Grusell E, Olsson LE. Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements. Phys Med Biol 1999; 44:1983-96. [PMID: 10473209 DOI: 10.1088/0031-9155/44/8/310] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.
Collapse
|
97
|
Gambarini G, Arrigoni S, Cantone MC, Molho N, Facchielli L, Sichirollo AE. Dose-response curve slope improvement and result reproducibility of ferrous-sulphate-doped gels analysed by NMR imaging. Phys Med Biol 1999; 39:703-17. [PMID: 15552079 DOI: 10.1088/0031-9155/39/4/004] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Ferrous sulphate gel analysed by relaxation time measurements with NMR imaging is considered a useful dosimeter for 3D determinations of absorbed dose. A protocol for the gel preparation with agarose SeaPlaque that leads to a dosimeter with very high dose sensitivity is described. The dose-response curve slope is about 0.2 s(-1) Gy(-1) and the G factor turns out to be approximately 185 ions per 100 eV of absorbed energy. A method for making the measurements and analysing the results that brings about good result reproducibility is suggested. A thorough experimental study of the dependence of the dosimeter response on the elapsed time from preparation to irradiation and from irradiation to NMR measurement has revealed good reproducibility. The above characteristic of the gel system is very interesting, because it shows the possibility of utilizing the dosimeter for absolute dose determinations with satisfactory reliability.
Collapse
|
98
|
Oldham M, McJury M, Baustert IB, Webb S, Leach MO. Improving calibration accuracy in gel dosimetry. Phys Med Biol 1998; 43:2709-20. [PMID: 9814511 DOI: 10.1088/0031-9155/43/10/002] [Citation(s) in RCA: 89] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10 x 10 cm2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (Dmax), and the other to 4.5 Gy at Dmax. The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233 +/- 0.001 s(-1) Gy(-1) and an intercept of 1.106 +/- 0.005 Gy. For higher doses, nonlinear behaviour was observed.
Collapse
|
99
|
Rousselle I, Castelain B, Coche-Dequeant B, Sarrazin T, Rousseau J. [Dosimetric quality control in stereotactic radiotherapy with the aid of radiosensitivity]. Cancer Radiother 1998; 2:139-45. [PMID: 9749108 DOI: 10.1016/s1278-3218(98)89084-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Typical dosimeters used in stereotactic radiation therapy, such as ionization chambers, films, and thermoluminescent diodes, allow basic physical measurements. They are, however, neither well suited to discern small target volumes with high dose gradient, nor suitable for three-dimensional (3D) dose measurements. Gel dosimetry is becoming more and more interesting, owing to magnetic resonance imaging (MRI). It permits isocenter position planning verification of accuracy and the precision of the 3D dose mapping in the brain (when irradiated in realistic conditions), especially when several different targets are concerned. Many authors have assessed stereotactic radiation therapy quality control using different gels, and different irradiation procedures. This paper consists of the review of these different methods to assess quality control. Gel dosimetry cannot provide absolute dose measurements. However, gels can be used to check the 3D dose mapping with a high degree of detail. In our experiment, the difference between the stereotactic frame center and the isocenter is about 1 mm. The difference between the theoretical isodoses obtained by the treatment planning system and the experimental isodoses obtained by the MRI gray level calibration is also about 1 mm, the order of magnitude of the MRI pixel size.
Collapse
|
100
|
de Queiroz AA, Castro SC, Higa OZ. Adsorption of plasma proteins to DMAA hydrogels obtained by ionizing radiation and its relationship with blood compatibility. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 1997; 8:335-47. [PMID: 9105974 DOI: 10.1163/156856297x00137] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The interaction of plasma proteins such as albumin, gamma-globulin, and fibrinogen with the surface of graft copolymers DMAA-G-PTFE, DMAA-G-PETFE, and DMAA-G-PE obtained by radiation graft polymerization was studied. The adsorption of serum proteins was affected by the hydrophilicity of the graft copolymers. Increased albumin adsorption and decreased fibrinogen and gamma-globulin adsorption with increasing grafting levels was shown. A certain range of degrees of grafting showed an improved blood compatibility of the polymeric surfaces due to the existence of a hydrophilic/hydrophobic balance on the polymers. The results suggest that the DMAA-G-PTFE, DMAA-G-PETFE, and DMAA-G-PE graft copolymers can be used as biomaterials for long-term use in cardiovascular systems.
Collapse
|