26
|
ElHadidy AM, Peldszus S, Van Dyke MI. Effect of hydraulically reversible and hydraulically irreversible fouling on the removal of MS2 and φX174 bacteriophage by an ultrafiltration membrane. WATER RESEARCH 2014; 61:297-307. [PMID: 24967952 DOI: 10.1016/j.watres.2014.05.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 04/02/2014] [Accepted: 05/03/2014] [Indexed: 05/13/2023]
Abstract
The effect of membrane fouling on the removal of enteric virus surrogates MS2 and φX174 bacteriophage by an ultrafiltration membrane was assessed under simulated full-scale drinking water treatment operating conditions. Filtration experiments of up to 8 days using either river or lake water ascertained how the membrane fouling layer affected virus removal. Organic carbon fractionation techniques identified potential foulants, including biopolymers, in the feed water and in the permeate. Hydraulically irreversible fouling could greatly improve the removal of both viruses at moderate and severe fouling conditions by up to 2.5 logs. Hydraulically reversible fouling increased virus removal only slightly, and increased removal of >0.5 log for both phage were only obtained under severe fouling conditions. The increase in virus removal due to irreversible and reversible fouling differed between the two water sources. As the degree of fouling increased, differences between the removal of the two phage decreased. Maintenance cleaning partially removed membrane foulants, however virus removal following maintenance cleaning was lower than that of the fouled membrane, it remained higher than that of the clean membrane.
Collapse
|
27
|
Wang H, Narihiro T, Straub AP, Pugh CR, Tamaki H, Moor JF, Bradley IM, Kamagata Y, Liu WT, Nguyen TH. MS2 bacteriophage reduction and microbial communities in biosand filters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:6702-6709. [PMID: 24857308 DOI: 10.1021/es500494s] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This study evaluated the role of physical and biological filter characteristics on the reduction of MS2 bacteriophage in biosand filters (BSFs). Three full-scale concrete Version 10 BSFs, each with a 55 cm sand media depth and a 12 L charge volume, reached 4 log10 reduction of MS2 within 43 days of operation. A consistently high reduction of MS2 between 4 log10 and 7 log10 was demonstrated for up to 294 days. Further examining one of the filters revealed that an average of 2.8 log10 reduction of MS2 was achieved within the first 5 cm of the filter, and cumulative virus reduction reached an average of 5.6 log10 after 240 days. Core sand samples from this filter were taken for protein, carbohydrate, and genomic extraction. Higher reduction of MS2 in the top 5 cm of the sand media (0.56 log10 reduction per cm vs 0.06 log10 reduction per cm for the rest of the filter depth) coincided with greater diversity of microbial communities and increased concentrations of carbohydrates. In the upper layers, "Candidatus Nitrosopumilus maritimus" and "Ca. Nitrospira defluvii" were found as dominant populations, while significant amounts of Thiobacillus-related OTUs were detected in the lower layers. Proteolytic bacterial populations such as the classes Sphingobacteria and Clostridia were observed over the entire filter depth. Thus, this study provides the first insight into microbial community structures that may play a role in MS2 reduction in BSF ecosystems. Overall, besides media ripening and physical reduction mechanisms such as filter depth and long residence time (45 min vs 24 ± 8.5 h), the establishment of chemolithotrophs and proteolytic bacteria could greatly enhance the reduction of MS2.
Collapse
|
28
|
Park JA, Kang JK, Kim JH, Kim SB, Yu S, Kim TH. Transport and removal of bacteriophages MS2 and PhiX174 in steel slag-amended soils: column experiments and transport model analyses. ENVIRONMENTAL TECHNOLOGY 2014; 35:1199-1207. [PMID: 24701916 DOI: 10.1080/09593330.2013.865061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The aim of this study was to investigate the removal of bacteriophages MS2 and PhiX174 in soils amended with converter furnace steel slag. Column experiments were performed to examine the bacteriophage removal in slag-amended (slag content: 0%, 25%, and 50%) loam soils. For comparison, column experiments were also conducted with Escherichia coli. In addition, chloride (Cl) was used as a conservative tracer to determine transport characteristics. Results showed mass recoveries of Cl of 98.6 +/- 3.5%, indicating that the experiments were conducted successfully. The mass recovery of MS2 was 86.7% in no slag (100% soil), decreasing to 0% in slag contents of 25% and 50%. The mass recovery of PhiX174 decreased from 87.8% to 51.5% with increasing slag content from 0% to 50%. In the case of E. coli, the mass recoveries decreased from 47.0% to 10.5% with increasing slag content from 0% to 50%. In the transport models analyses, the HYDRUS-1D code was used to quantify the sorption parameters from breakthrough curves. For the 100% soil column, a one-site kinetic sorption model was fitted to the data, whereas a two-site kinetic sorption model was fitted for slag-amended (25% and 50% slag) soil data. Results demonstrate that the addition of steel slag to soil enhances the removal of bacteriophages due to the presence of FeO in the steel slag. However, CaO could not contribute to the bacteriophage removal in our experimental conditions because the effluent pH (7.7-8.9) in slag-amended (25% and 50% slag) soils was not high enough to promote the bacteriophage inactivation.
Collapse
|
29
|
van der Laan H, van Halem D, Smeets PWMH, Soppe AIA, Kroesbergen J, Wubbels G, Nederstigt J, Gensburger I, Heijman SGJ. Bacteria and virus removal effectiveness of ceramic pot filters with different silver applications in a long term experiment. WATER RESEARCH 2014; 51:47-54. [PMID: 24388830 DOI: 10.1016/j.watres.2013.11.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 10/31/2013] [Accepted: 11/10/2013] [Indexed: 05/03/2023]
Abstract
In 2012 more than 4 million people used a ceramic pot filter (CPF) as household water treatment system for their daily drinking water needs. In the normal production protocol most low cost filters are impregnated with a silver solution to enhance the microbial removal efficiency. The aim of this study was to determine the role of silver during the filtration and subsequent storage. Twenty-two CPFs with three different silver applications (non, only outside and both sides) were compared in a long-term loading experiment with Escherichia coli (K12 and WR1) and MS2 bacteriophages in natural challenge water under highly controlled laboratory circumstances. No significant difference in Log Removal Values were found between the filters with different silver applications. The results show that the storage time in the receptacle is the dominant parameter to reach E. coli inactivation by silver, and not the contact time during the filtration phase. The hypothesis that the absence of silver would enhance the virus removal, due to biofilm formation on the ceramic filter element, could not be confirmed. The removal effectiveness for viruses is still of major concern for the CPF. This study suggests that the ceramic pot filter characteristics, such as burnt material content, do not determine E. coli removal efficacies, but rather the contact time with silver during storage is the dominant parameter to reach E. coli inactivation.
Collapse
|
30
|
Cooper C, Slagley J, Lohaus J, Escamilla E, Bliss C, Semler D, Felker D, Smith D, Ott D. Comparison of high-volume air sampling equipment for viral aerosol sampling during emergency response. JOURNAL OF EMERGENCY MANAGEMENT (WESTON, MASS.) 2014; 12:161-170. [PMID: 24828912 DOI: 10.5055/jem.2014.0170] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVE This study compared the performance of two high-volume bioaerosol air samplers for viable virus to an accepted standard low-volume sampler. In typical bioaerosol emergency response scenarios, highvolume sampling is essential for the low infective concentrations and large air volumes involved. DESIGN Two high-volume air samplers (XMX/2LMIL and DFU-1000) were evaluated alongside a lowvolume sample (BioSampler). Low and high concentrations (9.3-93.2 agent containing particles per liter of air [ACPLA]) of male-specific coliphage 2 (MS2) virus were released into a 12 m3 aerosol test chamber and collected using the air samplers. The collection media from the samplers were then processed and viable virus was assessed via plaque assay. SETTING Aerosol test chamber. SUBJECTS, PARTICIPANTS None. INTERVENTIONS Collection media and flow rate were modified for the XMX/2L-MIL sampler for viable analysis. MAIN OUTCOME MEASURES Concentration estimates in units of plaque forming units per liter of air (PFU/liter) assessed by the samplers as compared to the levels inside the chamber as evaluated with a slit to agar plate in units of ACPLA. Comparison was made via one-way analysis of variance. RESULTS Both the XMX/2L-MIL and DFU-1000 achieved collection effectiveness equal to or greater than the low-volume air sampler for the evaluated MS2 concentrations. The XMX/2L-MIL reliably collected quantifiable low concentrations of MS2, but the DFU-1000 was unable to do so. CONCLUSIONS For emergency response to suspected bioaerosols, the evaluated high-volume samplers are as effective as the standard low-flow sampler and should be considered in conducting a health risk assessment. If low concentrations are expected, then high-flow samplers using liquid collection are preferred.
Collapse
|
31
|
Young-Rojanschi C, Madramootoo C. Intermittent versus continuous operation of biosand filters. WATER RESEARCH 2014; 49:1-10. [PMID: 24316177 DOI: 10.1016/j.watres.2013.11.011] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Revised: 11/08/2013] [Accepted: 11/10/2013] [Indexed: 06/02/2023]
Abstract
The biosand filter is a household-scale point-of-use water filtration system based on slow sand filtration, but modified for intermittent operation. Studies on slow sand filters show that intermittent operation reduces filter effectiveness. However, continuous versus intermittent operation of biosand filters has never been compared. Eight 10-cm diameter columns were constructed to represent field biosand filters. Five were operated intermittently with a 24-h residence period, while the remaining three were operated continuously. Continuous operation of the filters resulted in significantly better reduction of Escherichia coli (3.71 log10 versus 1.67 log10), bacteriophage MS2 (2.25 log10 versus 0.85 log10), and turbidity (96% versus 87%). Dissolved oxygen levels at 5 and 10 cm of media depth in intermittent filters reached an average of 0 mg/L by 24 h of residence time on day 60 of the experiment. A simple numerical model was developed to describe E. coli removal during ripening from days 0-58 for continuously operated versus intermittent filters. This research confirms that although biosand filters were developed for intermittent operation, the filters perform significantly better when operated continuously. However, both operational modes resulted in a significant reduction of microbial indicators.
Collapse
|
32
|
Lu R, Mosiman D, Nguyen TH. Mechanisms of MS2 bacteriophage removal by fouled ultrafiltration membrane subjected to different cleaning methods. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:13422-13429. [PMID: 24175731 DOI: 10.1021/es403426t] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
An ultrafiltration unit with a polyvinylidene fluoride (PVDF) membrane of 40 nm nominal pore size was used to study bacteriophage MS2 removal under different membrane conditions: pristine membrane, membrane fouled by soluble microbial product (SMP) extracted from membrane bioreactor (MBR) feedwater, backwashed membrane, and chemically cleaned membrane. The order of MS2 removal by these membranes was as follows: fouled membrane > backwashed membrane > chemically cleaned membrane ≈ pristine membrane. A linear correlation between membrane relative permeability and MS2 removal was found. Mass balance analysis showed a high percentage of MS2 in the concentrate for the fouled membrane as compared with the pristine membrane. Quartz crystal microbalance (QCM) results showed faster kinetics of MS2 adhesion to the pristine membrane than to the SMP-fouled membrane. In agreement with QCM results, an attractive force between MS2 and the pristine membrane was detected using an atomic force microscope (AFM), whereas a repulsive force was detected for the interaction between MS2 and the fouled membrane. The presence of SMP on the membrane surface led to higher rejection of MS2 due to both pore blocking and repulsion between MS2 and the SMP layer. Chemical cleaning removed most of the SMP foulant and as a result led to a lower MS2 removal.
Collapse
|
33
|
Carratalà A, Rodriguez-Manzano J, Hundesa A, Rusiñol M, Fresno S, Cook N, Girones R. Effect of temperature and sunlight on the stability of human adenoviruses and MS2 as fecal contaminants on fresh produce surfaces. Int J Food Microbiol 2013; 164:128-34. [PMID: 23673057 DOI: 10.1016/j.ijfoodmicro.2013.04.007] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 04/05/2013] [Accepted: 04/08/2013] [Indexed: 11/23/2022]
Abstract
Determining the stability, or persistence in an infectious state, of foodborne viral pathogens attached to surfaces of soft fruits and salad vegetables is essential to underpin risk assessment studies in food safety. Here, we evaluate the effect of temperature and sunlight on the stability of infectious human adenoviruses type 2 and MS2 bacteriophages on lettuce and strawberry surfaces as representative fresh products. Human adenoviruses have been selected because of their double role as viral pathogens and viral indicators of human fecal contamination. Stability assays were performed with artificially contaminated fresh samples kept in the dark or under sunlight exposure at 4 and 30°C over 24h. The results indicate that temperature is the major factor affecting HAdV stability in fresh produce surfaces, effecting decay between 3 and 4 log after 24h at 30°C. The inactivation times to achieve a reduction between 1 and 4-log are calculated for each experimental condition. This work provides useful information to be considered for improving food safety regarding the transmission of foodborne viruses through supply chains.
Collapse
|
34
|
Yavarmanesh M, Abbaszadegan M, Alum A, Mortazavi A, Habibi Najafi MB, Bassami MR, Nassiri MR. Impact of milk components on recovery of viral RNA from MS2 bacteriophage. FOOD AND ENVIRONMENTAL VIROLOGY 2013; 5:103-109. [PMID: 23430411 DOI: 10.1007/s12560-013-9107-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Accepted: 02/12/2013] [Indexed: 06/01/2023]
Abstract
Noroviruses are responsible for approximately 44 % of outbreaks involving dairy products for which causative agents are reported. Recovery of viruses from milk and dairy products is a difficult task. The role of different components of milk in the recovery of viral RNA was evaluated in this study. Four model milk formulations (A-D) were prepared by mixing different combinations of lactose, whey protein, casein, and fat in water. Each model formulation was spiked with five concentrations of bacteriophage MS2. The phenol-guanidine thiocyanate-chloroform protocol was used for extracting viral RNA from the model milk formulations and then extracted RNA was measured by a nanodrop spectrophotometer in ng/μl. The results showed that casein and whey protein had the highest negative impact on RNA yield, especially when the number of MS2 was less than 1.3 pfu/ml. The highest RNA recovery was obtained from the model milk formulation containing all four components; lactose, whey protein, casein, and fat. The amount of extracted RNA was closely correlated with the dry matter content of each formulation and the spiked concentration of coliphage using response surface modeling (R²:0.93). It was determined that milk fat is the most effective component in facilitating RNA extraction and the highest RNA yield can be achieved via elimination of whey protein and casein from milk by centrifugation at 40,000×g for 60 min. To achieve the highest viral RNA recovery efficiency by the proposed method, milk fat must be recombined with the supernatant of the centrifuged sample and then homogenized before performing the extraction protocol.
Collapse
|
35
|
Tanneru CT, Rimer JD, Chellam S. Sweep flocculation and adsorption of viruses on aluminum flocs during electrochemical treatment prior to surface water microfiltration. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:4612-8. [PMID: 23565986 DOI: 10.1021/es400291e] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Bench-scale experiments were performed to evaluate virus control by an integrated electrochemical-microfiltration (MF) process from turbid (15 NTU) surface water containing moderate amounts of dissolved organic carbon (DOC, 5 mg C/L) and calcium hardness (50 mg/L as CaCO3). Higher reductions in MS2 bacteriophage concentrations were obtained by aluminum electrocoagulation and electroflotation compared with conventional aluminum sulfate coagulation. This was attributed to electrophoretic migration of viruses, which increased their concentrations in the microenvironment of the sacrificial anode where coagulant precursors are dissolved leading to better destabilization during electrolysis. In all cases, viruses were not inactivated implying measured reductions were solely due to their removal. Sweep flocculation was the primary virus destabilization mechanism. Direct evidence for virus enmeshment in flocs was provided by two independent methods: quantitative elution using beef extract at elevated pH and quantitating fluorescence from labeled viruses. Atomic force microscopy studies revealed a monotonically increasing adhesion force between viruses immobilized on AFM tips and floc surfaces with electrocoagulant dosage, which suggests secondary contributions to virus uptake on flocs from adsorption. Virus sorption mechanisms include charge neutralization and hydrophobic interactions with natural organic matter removed during coagulation. This also provided the basis for interpreting additional removal of viruses by the thick cake formed on the surface of the microfilter following electrocoagulation. Enhancements in virus removal as progressively more aluminum was electrolyzed therefore embodies contributions from (i) better encapsulation onto greater amounts of fresh Al(OH)3 precipitates, (ii) increased adsorption capacity associated with higher available coagulant surface area, (iii) greater virus-floc binding affinity due to effective charge neutralization and hydrophobic interactions, and/or (iv) additional removal by a dynamic membrane if a thick cake layer of flocs is deposited.
Collapse
|
36
|
Schijven JF, van den Berg HHJL, Colin M, Dullemont Y, Hijnen WAM, Magic-Knezev A, Oorthuizen WA, Wubbels G. A mathematical model for removal of human pathogenic viruses and bacteria by slow sand filtration under variable operational conditions. WATER RESEARCH 2013. [PMID: 23490102 DOI: 10.1016/j.watres.2014.07.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Slow sand filtration (SSF) in drinking water production removes pathogenic microorganisms, but detection limits and variable operational conditions complicate assessment of removal efficiency. Therefore, a model was developed to predict removal of human pathogenic viruses and bacteria as a function of the operational conditions. Pilot plant experiments were conducted, in which bacteriophage MS2 and Escherichia coli WR1 were seeded as model microorganisms for pathogenic viruses and bacteria onto the filters under various temperatures, flow rates, grain sizes and ages of the Schmutzdecke. Removal of MS2 was 0.082-3.3 log10 and that of E. coli WR1 0.94-4.5 log10 by attachment to the sand grains and additionally by processes in the Schmutzdecke. The contribution of the Schmutzdecke to the removal of MS2 and E. coli WR1 increased with its ageing, with sticking efficiency and temperature, decreased with grain size, and was modelled as a logistic growth function with scale factor f0 and rate coefficient f1. Sticking efficiencies were found to be microorganism and filter specific, but the values of f0 and f1 were independent of microorganism and filter. Cross-validation showed that the model can be used to predict log removal of MS2 and ECWR1 within ±0.6 log. Within the range of operational conditions, the model shows that removal of microorganisms is most sensitive to changes in temperature and age of the Schmutzdecke.
Collapse
|
37
|
Schijven JF, van den Berg HHJL, Colin M, Dullemont Y, Hijnen WAM, Magic-Knezev A, Oorthuizen WA, Wubbels G. A mathematical model for removal of human pathogenic viruses and bacteria by slow sand filtration under variable operational conditions. WATER RESEARCH 2013; 47:2592-2602. [PMID: 23490102 DOI: 10.1016/j.watres.2013.02.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Revised: 02/15/2013] [Accepted: 02/18/2013] [Indexed: 06/01/2023]
Abstract
Slow sand filtration (SSF) in drinking water production removes pathogenic microorganisms, but detection limits and variable operational conditions complicate assessment of removal efficiency. Therefore, a model was developed to predict removal of human pathogenic viruses and bacteria as a function of the operational conditions. Pilot plant experiments were conducted, in which bacteriophage MS2 and Escherichia coli WR1 were seeded as model microorganisms for pathogenic viruses and bacteria onto the filters under various temperatures, flow rates, grain sizes and ages of the Schmutzdecke. Removal of MS2 was 0.082-3.3 log10 and that of E. coli WR1 0.94-4.5 log10 by attachment to the sand grains and additionally by processes in the Schmutzdecke. The contribution of the Schmutzdecke to the removal of MS2 and E. coli WR1 increased with its ageing, with sticking efficiency and temperature, decreased with grain size, and was modelled as a logistic growth function with scale factor f0 and rate coefficient f1. Sticking efficiencies were found to be microorganism and filter specific, but the values of f0 and f1 were independent of microorganism and filter. Cross-validation showed that the model can be used to predict log removal of MS2 and ECWR1 within ±0.6 log. Within the range of operational conditions, the model shows that removal of microorganisms is most sensitive to changes in temperature and age of the Schmutzdecke.
Collapse
|
38
|
Poma HR, Rajal VB, Blanco Fernández MD, Barril PA, Giordano MO, Masachessi G, Martínez LC, Isa MB, Freire MC, López Riviello G, Cisterna D, Nates SV, Mbayed VA. Evaluation of concentration efficiency of the Pseudomonas aeruginosa phage PP7 in various water matrixes by different methods. ENVIRONMENTAL MONITORING AND ASSESSMENT 2013; 185:2565-76. [PMID: 22763654 PMCID: PMC5705224 DOI: 10.1007/s10661-012-2731-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Accepted: 06/11/2012] [Indexed: 05/17/2023]
Abstract
Enteric viruses monitoring in surface waters requires the concentration of viruses before detection assays. The aim of this study was to evaluate different methods in terms of recovery efficiencies of bacteriophage PP7 of Pseudomonas aeruginosa, measured by real-time PCR, using it as a viral control process in water analysis. Different nucleic acid extraction methods (silica-guanidinium thiocyanate, a commercial kit (Qiagen Viral RNA Kit) and phenol-chloroform with alcohol precipitation) exhibited very low recovery efficiencies (0.08-4.18 %), being the most efficient the commercial kit used for subsequent experiments. To evaluate the efficiency of three concentration methods, PBS (as model for clean water) and water samples from rivers were seeded to reach high (HC, 10(6) pfu ml(-1)) and low concentrations (LC, 10(4) pfu ml(-1)) of PP7. Tangential ultrafiltration proved to be more efficient (50.36 ± 12.91, 17.21 ± 9.22 and 12.58 ± 2.35 % for HC in PBS and two river samples, respectively) than adsorption-elution with negatively charged membranes (1.00 ± 1.34, 2.79 ± 2.62 and 0.05 ± 0.08 % for HC in PBS and two river samples, respectively) and polyethylene glycol precipitation (15.95 ± 7.43, 4.01 ± 1.12 and 3.91 ± 0.54 %, for HC in PBS and two river samples, respectively), being 3.2-50.4 times more efficient than the others for PBS and 2.7-252 times for river samples. Efficiencies also depended on the initial virus concentration and aqueous matrixes composition. In consequence, the incorporation of an internal standard like PP7 along the process is useful as a control of the water concentration procedure, the nucleic acid extraction, the presence of inhibitors and the variability of the recovery among replicas, and for the calculation of the sample limit of detection. Thus, the use of a process control, as presented here, is crucial for the accurate quantification of viral contamination.
Collapse
|
39
|
Michen B, Fritsch J, Aneziris C, Graule T. Improved virus removal in ceramic depth filters modified with MgO. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:1526-33. [PMID: 23286835 DOI: 10.1021/es303685a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Ceramic filters, working on the depth filtration principle, are known to improve drinking water quality by removing human pathogenic microorganisms from contaminated water. However, these microfilters show no sufficient barrier for viruses having diameters down to 20 nm. Recently, it was shown that the addition of positively charged materials, for example, iron oxyhydroxide, can improve virus removal by adsorption mechanisms. In this work, we modified a common ceramic filter based on diatomaceous earth by introducing a novel virus adsorbent material, magnesium oxyhydroxide, into the filter matrix. Such filters showed an improved removal of about 4-log in regard to bacteriophages MS2 and PhiX174. This is explained with the electrostatic enhanced adsorption approach that is the favorable adsorption of negatively charged viruses onto positively charged patches in an otherwise negatively charged filter matrix. Furthermore, we provide theoretical evidence applying calculations according to Derjaguin-Landau-Verwey-Overbeek theory to strengthen our experimental results. However, modified filters showed a significant variance in virus removal efficiency over the course of long-term filtration experiments with virus removal increasing with filter operation time (or filter aging). This is explained by transformational changes of MgO in the filter upon contact with water. It also demonstrates that filter history is of great concern when filters working on the adsorption principles are evaluated in regard to their retention performance as their surface characteristics may alter with use.
Collapse
|
40
|
Chen L, Wei J, Wang W, Wang C. Combination of microalgae cultivation with membrane processes for the treatment of municipal wastewater. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2013; 68:2374-2381. [PMID: 24334885 DOI: 10.2166/wst.2013.509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The treatment of wastewater by microalgae cultivation has attracted more and more attention. However, the way to harvest microalgae cells from the wastewater and the treatment of the large quantity of residual solution have become critical issues. In this work, a new approach for the treatment of municipal wastewater is presented. The combination of flocculation for removing mainly microalgae and thereafter membrane filtration for chemical oxygen demand (COD) and conductivity reduction of the residual solution after flocculation is discussed. The COD concentration of the wastewater decreased from 260 to 84 mg/L after flocculation by chitosan. Five ultrafiltration (UF) membranes and two nanofiltration (NF) membranes were used for filtration to find a suitable membrane for COD and conductivity reduction. Among the five UF membranes, GR82PE showed the best performance, whose permeate flux and COD retention at 4 bar were 189.66 L/(m(2)·h) and 43.03%, respectively. NF membranes showed higher COD and conductivity retentions than UF membranes. The COD retention of Desal5-DK reached 98.3% at 20 bar. Lastly, the flux recovery after the filtration test of each membrane is also discussed.
Collapse
|
41
|
Schaar H, Sommer R, Schürhagl R, Yillia P, Kreuzinger N. Microorganism inactivation by an ozonation step optimized for micropollutant removal from tertiary effluent. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2013; 68:311-318. [PMID: 23863422 DOI: 10.2166/wst.2013.212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper demonstrates the additional benefit of the microbicidal efficacy of an ozonation plant implemented for micropollutant removal from tertiary effluent. Due to the low amount of viruses and protozoa in the tertiary effluent, bacteriophage MS2 and spores of Bacillus subtilis were dosed as surrogates. At specific ozone consumptions of 0.6 and 0.9 g O3/g dissolved organic carbon (DOC) a 2-log colony forming unit (CFU) reduction was achieved for indigenous Escherichia coli and enterococci, and the limits of the European bathing water directive for the excellent quality of inland waters were met. Higher removal was impeded by the shielding effect of suspended solids in the effluent, which implies the combination of ozonation with a preceding filtration step if higher microbicidal performances are required. The surrogate virus MS2 was reduced by 4-5 log while no significant inactivation was detected for B. subtilis spores. Additionally, the impact of ozonation on the biochemical oxygen demand (BOD) was studied. The BOD5 measurement was not adversely affected despite the reduced concentration of microorganisms after ozonation. The intrinsic increase in BOD5 averaged 15% at 0.6-0.7 g O3/g DOC. The impact of the projected increase on the surface water quality is generally not considered a problem but has to be assessed on a case-by-case approach.
Collapse
|
42
|
Brown J, Chai R, Wang A, Sobsey MD. Microbiological effectiveness of mineral pot filters in Cambodia. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2012; 46:12055-12061. [PMID: 23030639 DOI: 10.1021/es3027852] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Mineral pot filters (MPFs) are household water treatment (HWT) devices that are manufactured and distributed by the private sector, with millions of users in Southeast Asia. Their effectiveness in reducing waterborne microbes has not been previously investigated. We purchased three types of MPFs available on the Cambodian market for systematic evaluation of bacteria, virus, and protozoan surrogate microbial reduction in laboratory challenge experiments following WHO recommended performance testing protocols. Results over the total 1500 L testing period per filter indicate that the devices tested were highly effective in reducing Esherichia coli (99.99%+), moderately effective in reducing bacteriophage MS2 (99%+), and somewhat effective against Bacillus atrophaeus, a spore-forming bacterium we used as a surrogate for protozoa (88%+). Treatment mechanisms for all filters included porous ceramic and activated carbon filtration. Our results suggest that these commercially available filters may be at least as effective against waterborne pathogens as other, locally available treatment options such as ceramic pot filters or boiling. More research is needed on the role these devices may play as interim solutions to the problem of unsafe drinking water in Cambodia and globally.
Collapse
|
43
|
Maguire-Boyle SJ, Liga MV, Li Q, Barron AR. Alumoxane/ferroxane nanoparticles for the removal of viral pathogens: the importance of surface functionality to nanoparticle activity. NANOSCALE 2012; 4:5627-5632. [PMID: 22864822 DOI: 10.1039/c2nr31117h] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A bi-functional nano-composite coating has been created on a porous Nomex® fabric support as a trap for aspirated virus contaminated water. Nomex® fabric was successively dip-coated in solutions containing cysteic acid functionalized alumina (alumoxane) nanoparticles and cysteic acid functionalized iron oxide (ferroxane) nanoparticles to form a nanoparticle coated Nomex® (NPN) fabric. From SEM and EDX the nanoparticle coating of the Nomex® fibers is uniform, continuous, and conformal. The NPN was used as a filter for aspirated bacteriophage MS2 viruses using end-on filtration. All measurements were repeated to give statistical reliability. The NPN fabrics show a large decrease as compared to Nomex® alone or alumoxane coated Nomex®. An increase in the ferroxane content results in an equivalent increase in virus retention. This suggests that it is the ferroxane that has an active role in deactivating and/or binding the virus. Heating the NPN to 160 °C results in the loss of cysteic acid functional groups (without loss of the iron nanoparticle's core structure) and the resulting fabric behaves similar to that of untreated Nomex®, showing that the surface functionalization of the nanoparticles is vital for the surface collapse of aspirated water droplets and the absorption and immobilization of the MS2 viruses. Thus, for virus immobilization, it is not sufficient to have iron oxide nanoparticles per se, but the surface functionality of a nanoparticle is vitally important in ensuring efficacy.
Collapse
|
44
|
Pei L, Rieger M, Lengger S, Ott S, Zawadsky C, Hartmann NM, Selinka HC, Tiehm A, Niessner R, Seidel M. Combination of crossflow ultrafiltration, monolithic affinity filtration, and quantitative reverse transcriptase PCR for rapid concentration and quantification of model viruses in water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2012; 46:10073-10080. [PMID: 22917471 DOI: 10.1021/es302304t] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We present a rapid and effective adsorption-elution method based on monolithic affinity filtration (MAF) for the concentration and purification of waterborne viruses. The MAF column consists of a hydrolyzed macroporous epoxy-based polymer. High recoveries were achieved by columns for the bacterial virus (bacteriophage) MS2 110 (±19)%, as model organism, as well as for human adenoviruses 42.4 (±3.4)% and murine noroviruses 42.6 (±1.9)%. This new concentration and purification method was combined with crossflow ultrafiltration (CUF). Because of the adsorption of the examined viruses to the macroporous surface of the MAF column at pH 3, concentrated matrix components by CUF can be removed. Bacteriophages MS2 were spiked in tap water and concentrated with the new CUF-MAF concentration method by a volumetric factor of 10(4) within 33 min. Furthermore, the detection limit for quantification of bacteriophage MS2 by quantitative reverse transcriptase PCR (qRT-PCR) could be improved from 79.47 to 0.0056 GU mL(-1) by a factor of 1.4 × 10(4). In a first study, we have shown that this method could also be applied for river water containing naturally MS2 and MS2-like phages.
Collapse
|
45
|
Woo MH, Grippin A, Anwar D, Smith T, Wu CY, Wander JD. Effects of relative humidity and spraying medium on UV decontamination of filters loaded with viral aerosols. Appl Environ Microbiol 2012; 78:5781-7. [PMID: 22685135 PMCID: PMC3406129 DOI: 10.1128/aem.00465-12] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2012] [Accepted: 05/30/2012] [Indexed: 11/20/2022] Open
Abstract
Although respirators and filters are designed to prevent the spread of pathogenic aerosols, a stockpile shortage is anticipated during the next flu pandemic. Contact transfer and reaerosolization of collected microbes from used respirators are also a concern. An option to address these potential problems is UV irradiation, which inactivates microbes by dimerizing thymine/uracil in nucleic acids. The objective of this study was to determine the effects of transmission mode and environmental conditions on decontamination efficiency by UV. In this study, filters were contaminated by different transmission pathways (droplet and aerosol) using three spraying media (deionized water [DI], beef extract [BE], and artificial saliva [AS]) under different humidity levels (30% [low relative humidity {LRH}], 60% [MRH], and 90% [HRH]). UV irradiation at constant intensity was applied for two time intervals at each relative humidity condition. The highest inactivation efficiency (IE), around 5.8 logs, was seen for DI aerosols containing MS2 on filters at LRH after applying a UV intensity of 1.0 mW/cm(2) for 30 min. The IE of droplets containing MS2 was lower than that of aerosols containing MS2. Absorption of UV by high water content and shielding of viruses near the center of the aggregate are considered responsible for this trend. Across the different media, IEs in AS and in BE were much lower than in DI for both aerosol and droplet transmission, indicating that solids present in AS and BE exhibited a protective effect. For particles sprayed in a protective medium, RH is not a significant parameter.
Collapse
|
46
|
Moser MJ, DiFrancesco RA, Gowda K, Klingele AJ, Sugar DR, Stocki S, Mead DA, Schoenfeld TW. Thermostable DNA polymerase from a viral metagenome is a potent RT-PCR enzyme. PLoS One 2012; 7:e38371. [PMID: 22675552 PMCID: PMC3366922 DOI: 10.1371/journal.pone.0038371] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2011] [Accepted: 05/04/2012] [Indexed: 02/03/2023] Open
Abstract
Viral metagenomic libraries are a promising but previously untapped source of new reagent enzymes. Deep sequencing and functional screening of viral metagenomic DNA from a near-boiling thermal pool identified clones expressing thermostable DNA polymerase (Pol) activity. Among these, 3173 Pol demonstrated both high thermostability and innate reverse transcriptase (RT) activity. We describe the biochemistry of 3173 Pol and report its use in single-enzyme reverse transcription PCR (RT-PCR). Wild-type 3173 Pol contains a proofreading 3′-5′ exonuclease domain that confers high fidelity in PCR. An easier-to-use exonuclease-deficient derivative was incorporated into a PyroScript RT-PCR master mix and compared to one-enzyme (Tth) and two-enzyme (MMLV RT/Taq) RT-PCR systems for quantitative detection of MS2 RNA, influenza A RNA, and mRNA targets. Specificity and sensitivity of 3173 Pol-based RT-PCR were higher than Tth Pol and comparable to three common two-enzyme systems. The performance and simplified set-up make this enzyme a potential alternative for research and molecular diagnostics.
Collapse
|
47
|
Boudaud N, Machinal C, David F, Fréval-Le Bourdonnec A, Jossent J, Bakanga F, Arnal C, Jaffrezic MP, Oberti S, Gantzer C. Removal of MS2, Qβ and GA bacteriophages during drinking water treatment at pilot scale. WATER RESEARCH 2012; 46:2651-64. [PMID: 22421032 DOI: 10.1016/j.watres.2012.02.020] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 01/27/2012] [Accepted: 02/11/2012] [Indexed: 05/04/2023]
Abstract
The removal of MS2, Qβ and GA, F-specific RNA bacteriophages, potential surrogates for pathogenic waterborne viruses, was investigated during a conventional drinking water treatment at pilot scale by using river water, artificially and independently spiked with these bacteriophages. The objective of this work is to develop a standard system for assessing the effectiveness of drinking water plants with respect to the removal of MS2, Qβ and GA bacteriophages by a conventional pre-treatment process (coagulation-flocculation-settling-sand filtration) followed or not by an ultrafiltration (UF) membrane (complete treatment process). The specific performances of three UF membranes alone were assessed by using (i) pre-treated water and (ii) 0.1 mM sterile phosphate buffer solution (PBS), spiked with bacteriophages. These UF membranes tested in this work were designed for drinking water treatment market and were also selected for research purpose. The hypothesis serving as base for this study was that the interfacial properties for these three bacteriophages, in terms of electrostatic charge and the degree of hydrophobicity, could induce variations in the removal performances achieved by drinking water treatments. The comparison of the results showed a similar behaviour for both MS2 and Qβ surrogates whereas it was particularly atypical for the GA surrogate. The infectious character of MS2 and Qβ bacteriophages was mostly removed after clarification followed by sand filtration processes (more than a 4.8-log reduction) while genomic copies were removed at more than a 4.0-log after the complete treatment process. On the contrary, GA bacteriophage was only slightly removed by clarification followed by sand filtration, with less than 1.7-log and 1.2-log reduction, respectively. After the complete treatment process achieved, GA bacteriophage was removed with less than 2.2-log and 1.6-log reduction, respectively. The effectiveness of the three UF membranes tested in terms of bacteriophages removal showed significant differences, especially for GA bacteriophage. These results could provide recommendations for drinking water suppliers in terms of selection criteria for membranes. MS2 bacteriophage is widely used as a surrogate for pathogenic waterborne viruses in Europe and the United States. In this study, the choice of MS2 bacteriophage as the best surrogate to be used for assessment of the effectiveness of drinking water treatment in removal of pathogenic waterborne viruses in worst conditions is clearly challenged. It was shown that GA bacteriophage is potentially a better surrogate as a worst case than MS2. Considering GA bacteriophage as the best surrogate in this study, a chlorine disinfection step could guaranteed a complete removal of this model and ensure the safety character of drinking water plants.
Collapse
|
48
|
Tanneru CT, Chellam S. Mechanisms of virus control during iron electrocoagulation--microfiltration of surface water. WATER RESEARCH 2012; 46:2111-20. [PMID: 22326196 DOI: 10.1016/j.watres.2012.01.032] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2011] [Revised: 01/21/2012] [Accepted: 01/23/2012] [Indexed: 05/03/2023]
Abstract
Results from a laboratory-scale study evaluating virus control by a hybrid iron electrocoagulation - microfiltration process revealed only 1.0-1.5 log MS2 bacteriophage reduction even at relatively high iron dosages (≈ 13 mg/L as Fe) for natural surface water containing moderate natural organic matter (NOM) concentrations (4.5 mg/L dissolved organic carbon, DOC). In contrast, much greater reductions were measured (6.5-log at pH 6.4 and 4-log at pH 7.5) at similar iron dosages for synthetic water that was devoid of NOM. Quantitative agreement with Faraday's law with 2-electron transfer and speciation with phenanthroline demonstrated electrochemical generation of soluble ferrous iron. Near quantitative extraction of viruses by dissolving flocs formed in synthetic water provided direct evidence of their removal by sorption and enmeshment onto iron hydroxide flocs. In contrast, only approximately 1% of the viruses were associated with the flocs formed in natural water consistent with the measured poor removals. 1-2 logs of virus inactivation were also observed in the electrochemical cell for synthetic water (no NOM) but not for surface water (4.5 mg/L DOC). Sweep flocculation was the dominant destabilization mechanism since the ζ potential did not reach zero even when 6-log virus reductions were achieved. Charge neutralization only played a secondary role since ζ potential → 0 with increasing iron electrocoagulant dosage. Importantly, virus removal from synthetic water decreased when Suwanee River Humic Acid was added. Therefore, NOM present in natural waters appears to reduce the effectiveness of iron electrocoagulation pretreatment to microfiltration for virus control by complexing ferrous ions. This inhibits (i) Fe(2+) oxidation, precipitation, and virus destabilization and (ii) virus inactivation through reactive oxygen species intermediates or by direct interactions with Fe(2+) ions.
Collapse
|
49
|
Kim JH, Park JA, Kim SB. Mg/Al layered double hydroxide for bacteriophage removal in aqueous solution. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2012; 66:761-767. [PMID: 22766864 DOI: 10.2166/wst.2012.239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The objective of this study was to investigate the removal of bacteriophages in Mg/Al layered double hydroxide (LDH). Batch experiments were performed with bacteriophage MS2 in a powder form of Mg/Al LDH under various LDH doses. Column experiments were also performed under flow-through condition with bacteriophages MS2 and phiX174 in Mg/Al LDH immobilized on sand surfaces. Batch tests demonstrated that the powder form of Mg/Al LDH was effective in removing MS2 with the removal capacity of 2.2 × 10(8) plaque forming unit (pfu)/g under the given experimental conditions (LDH dose = 2 g/L; initial MS2 concentration = 4.61 × 10(5) pfu/mL). Column experiments showed that the log removal of phiX174 was 4.40 in columns containing 100% Mg/Al LDH-coated sand while it was 0.05 in 100% quartz sand. These findings indicated that Mg/Al LDH-coated sand was effective in removing bacteriophages compared with sand. A more than 4 log removal (=5.44) of MS2 was achieved in 100% Mg/Al LDH-coated sand. This study demonstrates the potential application of Mg/Al LDH for virus removal in water treatment.
Collapse
|
50
|
Lore MB, Sebastian JM, Brown TL, Viner AS, McCullough NV, Hinrichs SH. Performance of conventional and antimicrobial-treated filtering facepiece respirators challenged with biological aerosols. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2012; 9:69-80. [PMID: 22206440 DOI: 10.1080/15459624.2011.640273] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This study evaluated the filtration performance of four commercially available models of National Institute of Occupational Safety and Health (NIOSH)-certified filtering facepiece respirators (FFR) against both biological and inert aerosols at a flow rate of 85 L/min. Conventional N95 and P100 FFRs and two antimicrobial (AM)-treated FFRs (an N95 and a P95, both with iodine-based AM treatments) were tested for both physical penetration (PEN(P)) and viable penetration (PEN(V)) with three different bioaerosols, including MS2 bacteriophage virus, and the spores and vegetative cells of Bacillus atrophaeus bacteria, in addition to inert sodium chloride (NaCl) aerosol. For each FFR model, the PEN(P) measured with NaCl was predictive of its MS2 PEN(P), and it was observed that spores and bacteria aerosols were also filtered similarly to the inert aerosol. For both conventional FFRs, up to a 1-log reduction in PEN(V) in comparison with PEN(P) was observed and attributed to the experimental variability of the test system. For both models of AM-FFRs, no statistically significant differences between PEN(V) and PEN(P) for any of the three different bioaerosol challenges were observed. Thus, no bioaerosol filtration enhancement over the conventional FFRs was detected for either iodine-based AM-FFR. In the absence of any standardized test methods, we recommend that future studies evaluating the filtration performance of AM-treated FFRs incorporate the experimental best practices described herein.
Collapse
|