526
|
Inhibitory and bactericidal action of the bio corrosion agents «INCORGAS» and «AMDOR». Bioelectrochemistry 2013; 97:154-61. [PMID: 24210782 DOI: 10.1016/j.bioelechem.2013.09.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2012] [Revised: 07/11/2013] [Accepted: 09/28/2013] [Indexed: 11/23/2022]
Abstract
Inhibiting action of A, B and M-X compositions against hydrosulfide corrosion of carbon steel, hydrogen diffusion through the steel membrane has been studied along with their bactericidal effect with respect to sulfate-reducing bacteria of Desulfomicrobium type. Bactericidal properties of the compositions have been studied in the Postgate medium. Corrosion tests have been made in the NACE medium saturated by hydrogen sulfide and carbon dioxide separately and together by methods of gravimetrical measurements and linear polarization resistance (LRP). Potentiodynamic polarization and electrochemical diffusion method have been used. Steel protection is determined in the inhibited solutions by combined action of corrosion products film and inhibitor. Presence of sulfate-reducing bacteria in medium increases hydrogen diffusion flux through the steel membrane by 2-3 times and essentially stimulates effect of the inhibitors. The inhibiting compositions decrease quantity of sulfate-reducing bacteria (SRB) by 95-98%. The obtained results testify about predominately bacteriostatic action of the inhibiting compositions, which has influence on the enzymatic systems of SRB cells responsible directly for the sulfate reduction because of substantially decreasing the biogenic hydrogen sulfide concentration in the system.
Collapse
|
527
|
Comparison of different in vitro tests for biocompatibility screening of Mg alloys. Acta Biomater 2013; 9:8740-5. [PMID: 23429234 DOI: 10.1016/j.actbio.2013.02.020] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Revised: 01/21/2013] [Accepted: 02/12/2013] [Indexed: 12/13/2022]
Abstract
Standard cell culture tests according to ISO 10993 have only limited value for the biocompatibility screening of degradable biomaterials such as Mg alloys. The correlation between in vitro and in vivo results is poor. Standard cytotoxicity tests mimic the clinical situation to only a limited extent, since in vivo proteins and macromolecules in the blood and interstitial liquid will influence the corrosion behaviour and, hence, biocompatibility of Mg alloys to a significant extent. We therefore developed a modified cytotoxicity test simulating the in vivo conditions by use of bovine serum as the extraction vehicle instead of the cell culture medium routinely used in standard cytotoxicity testing according to ISO 10993-5. The modified extraction test was applied to eight experimental Mg alloys. Cytotoxicity was assayed by inhibition of cell metabolic activity (XTT test). When extraction of the alloy samples was performed in serum instead of cell culture medium the metabolic activity was significantly less inhibited for six of the eight alloys. The reduction in apparent cytotoxicity under serum extraction conditions was most pronounced for MgZn1 (109% relative metabolic activity with serum extracts vs. 26% in Dulbecco's modified Eagle's medium (DMEM)), for MgY4 (103% in serum vs. 32% in DMEM) and for MgAl3Zn1 (84% vs. 17%), resulting in a completely different cytotoxicity ranking of the tested materials when serum extraction was used. We suppose that this test system has the potential to enhance the predictability of in vivo corrosion behaviour and biocompatibility of Mg-based materials for biodegradable medical devices.
Collapse
|
528
|
Zhou WR, Zheng YF, Leeflang MA, Zhou J. Mechanical property, bio corrosion and in vitro biocompatibility evaluations of Mg-Li-(Al)-(RE) alloys for future cardiovascular stent application. Acta Biomater 2013; 9:8488-98. [PMID: 23385218 DOI: 10.1016/j.actbio.2013.01.032] [Citation(s) in RCA: 115] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Revised: 01/18/2013] [Accepted: 01/28/2013] [Indexed: 11/21/2022]
Abstract
Mg-Li-based alloys were investigated for future cardiovascular stent application as they possess excellent ductility. However, Mg-Li binary alloys exhibited reduced mechanical strengths due to the presence of lithium. To improve the mechanical strengths of Mg-Li binary alloys, aluminum and rare earth (RE) elements were added to form Mg-Li-Al ternary and Mg-Li-Al-RE quarternary alloys. In the present study, six Mg-Li-(Al)-(RE) alloys were fabricated. Their microstructures, mechanical properties and biocorrosion behavior were evaluated by using optical microscopy, X-ray diffraction, scanning electronic microscopy, tensile tests, immersion tests and electrochemical measurements. Microstructure characterization indicated that grain sizes were moderately refined by the addition of rare earth elements. Tensile testing showed that enhanced mechanical strengths were obtained, while electrochemical and immersion tests showed reduced corrosion resistance caused by intermetallic compounds distributed throughout the magnesium matrix in the rare-earth-containing Mg-Li alloys. Cytotoxicity assays, hemolysis tests as well as platelet adhesion tests were performed to evaluate in vitro biocompatibilities of the Mg-Li-based alloys. The results of cytotoxicity assays clearly showed that the Mg-3.5Li-2Al-2RE, Mg-3.5Li-4Al-2RE and Mg-8.5Li-2Al-2RE alloys suppressed vascular smooth muscle cell proliferation after 5day incubation, while the Mg-3.5Li, Mg-8.5Li and Mg-8.5Li-1Al alloys were proven to be tolerated. In the case of human umbilical vein endothelial cells, the Mg-Li-based alloys showed no significantly reduced cell viabilities except for the Mg-8.5Li-2Al-2RE alloy, with no obvious differences in cell viability between different culture periods. With the exception of Mg-8.5Li-2Al-2RE, all of the other Mg-Li-(Al)-(RE) alloys exhibited acceptable hemolysis ratios, and no sign of thrombogenicity was found. These in vitro experimental results indicate the potential of Mg-Li-(Al)-(RE) alloys as biomaterials for future cardiovascular stent application and the worthiness of investigating their biodegradation behaviors in vivo.
Collapse
|
529
|
Biofunctionalized anti-corrosive silane coatings for magnesium alloys. Acta Biomater 2013; 9:8671-7. [PMID: 23313945 DOI: 10.1016/j.actbio.2012.12.025] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2012] [Revised: 11/21/2012] [Accepted: 12/18/2012] [Indexed: 11/21/2022]
Abstract
Biodegradable magnesium alloys are advantageous in various implant applications, as they reduce the risks associated with permanent metallic implants. However, a rapid corrosion rate is usually a hindrance in biomedical applications. Here we report a facile two step procedure to introduce multifunctional, anti-corrosive coatings on Mg alloys, such as AZ31. The first step involves treating the NaOH-activated Mg with bistriethoxysilylethane to immobilize a layer of densely crosslinked silane coating with good corrosion resistance; the second step is to impart amine functionality to the surface by treating the modified Mg with 3-amino-propyltrimethoxysilane. We characterized the two-layer anticorrosive coating of Mg alloy AZ31 by Fourier transform infrared spectroscopy, static contact angle measurement and optical profilometry, potentiodynamic polarization and AC impedance measurements. Furthermore, heparin was covalently conjugated onto the silane-treated AZ31 to render the coating haemocompatible, as demonstrated by reduced platelet adhesion on the heparinized surface. The method reported here is also applicable to the preparation of other types of biofunctional, anti-corrosive coatings and thus of significant interest in biodegradable implant applications.
Collapse
|
530
|
Effect of biologically relevant ions on the corrosion products formed on alloy AZ31B: an improved understanding of magnesium corrosion. Acta Biomater 2013; 9:8761-70. [PMID: 23535231 DOI: 10.1016/j.actbio.2013.03.026] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Revised: 02/04/2013] [Accepted: 03/18/2013] [Indexed: 11/21/2022]
Abstract
Simulated physiological solutions mimicking human plasma have been utilized to study the in vitro corrosion of biodegradable metals. However, corrosion and corrosion product formation are different for different solutions with varied responses and, hence, the prediction of in vivo degradation behavior is not feasible based on these studies alone. This paper reports the role of physiologically relevant salts and their concentrations on the corrosion behavior of a magnesium alloy (AZ31B) and subsequent corrosion production formation. Immersion tests were performed for three different concentrations of Ca(2+), HPO4(2-), HCO3(-) to identify the effect of each ion on the corrosion of AZ31B assessed at 1, 3 and 10 days. Time-lapse morphological characterization of the samples was performed using X-ray computed tomography and scanning electron microscopy. The chemical composition of the surface corrosion products was determined by electron dispersive X-ray spectroscopy and X-ray diffraction. The results show that: (1) calcium is not present in the corrosion product layer when only Cl(-) and OH(-) anions are available; (2) the presence of phosphate induces formation of a densely packed amorphous magnesium phosphate corrosion product layer when HPO4(2-) and Cl(-) are present in solution; (3) octacalcium phosphate and hydroxyapatite (HAp) are deposited on the surface of the magnesium alloy when HPO4(2-) and Ca(2+) are present together in NaCl solution (this coating limits localized corrosion and increases general corrosion resistance); (4) addition of HCO3(-) accelerates the overall corrosion rate, which increases with increasing bicarbonate concentration; (5) the corrosion rate decreases due to the formation of insoluble HAp on the surface when HCO3(-), Ca(2+), and HPO4(2-) are present together.
Collapse
|
531
|
A layer-by-layer approach to natural polymer-derived bioactive coatings on magnesium alloys. Acta Biomater 2013; 9:8690-703. [PMID: 23707500 DOI: 10.1016/j.actbio.2013.05.013] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Revised: 05/13/2013] [Accepted: 05/14/2013] [Indexed: 01/26/2023]
Abstract
The development of polyelectrolyte multilayered coatings on magnesium alloy substrates that can be used for controlled delivery of growth factors and required biomolecules from the surface of these degradable implants could have a significant impact in the field of bone tissue regeneration. The current work reports on the fabrication of multilayered coatings of alginate and poly-L-lysine on alkaline- and fluoride-pretreated AZ31 substrates using a layer-by-layer (LbL) technique under physiological conditions. Furthermore, these coatings were surface functionalized by chemical cross-linking and fibronectin immobilization, and the resultant changes in surface properties have been shown to influence the cellular activity of these multilayered films. The physicochemical characteristics of these coated substrates have been investigated using attenuated total reflectance Fourier transform infrared spectroscopy, atomic force microscopy, scanning electron microscopy and energy-dispersive X-ray spectroscopy. Cytocompatibility studies using MC3T3-E1 osteoblasts show that the fluoride-pretreated, cross-linked and fibronectin-immobilized LbL-coated substrates are more bioactive and less cytotoxic than the hydroxide-pretreated, cross-linked and fibronectin-immobilized LbL-coated samples. The in vitro degradation results show that the multilayered coatings of these natural polysaccharide- and synthetic polyamino acid-based polyelectrolytes do not alter the degradation kinetics of the substrates; however, the pretreatment conditions have a significant impact on the overall coating degradation behavior. These preliminary results collectively show the potential use of LbL coatings on magnesium-based degradable scaffolds to improve their surface bioactivity.
Collapse
|
532
|
Cui W, Beniash E, Gawalt E, Xu Z, Sfeir C. Biomimetic coating of magnesium alloy for enhanced corrosion resistance and calcium phosphate deposition. Acta Biomater 2013; 9:8650-9. [PMID: 23816653 DOI: 10.1016/j.actbio.2013.06.031] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Revised: 06/15/2013] [Accepted: 06/20/2013] [Indexed: 11/29/2022]
Abstract
Degradable metals have been suggested as biomaterials with revolutionary potential for bone-related therapies. Of these candidate metals, magnesium alloys appear to be particularly attractive candidates because of their non-toxicity and outstanding mechanical properties. Despite their having been widely studied as orthopedic implants for bone replacement/regeneration, their undesirably rapid corrosion rate under physiological conditions has limited their actual clinical application. This study reports the use of a novel biomimetic peptide coating for Mg alloys to improve the alloy corrosion resistance. A 3DSS biomimetic peptide is designed based on the highly acidic, bioactive bone and dentin extracellular matrix protein, phosphophoryn. Surface characterization techniques (scanning electron microscopy, energy dispersive X-ray spectroscopy and diffuse-reflectance infrared spectroscopy) confirmed the feasibility of coating the biomimetic 3DSS peptide onto Mg alloy AZ31B. The 3DSS peptide was also used as a template for calcium phosphate deposition on the surface of the alloy. The 3DSS biomimetic peptide coating presented a protective role of AZ31B in both hydrogen evolution and electrochemical corrosion tests.
Collapse
|
533
|
Wu W, Chen S, Gastaldi D, Petrini L, Mantovani D, Yang K, Tan L, Migliavacca F. Experimental data confirm numerical modeling of the degradation process of magnesium alloys stents. Acta Biomater 2013; 9:8730-9. [PMID: 23128160 DOI: 10.1016/j.actbio.2012.10.035] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2012] [Revised: 09/29/2012] [Accepted: 10/28/2012] [Indexed: 11/30/2022]
Abstract
Biodegradable magnesium alloy stents (MAS) could present improved long-term clinical performances over commercial bare metal or drug-eluting stents. However, MAS were found to show limited mechanical support for diseased vessels due to fast degradation. Optimizing stent design through finite element analysis (FEA) is an efficient way to improve such properties. Following previous FEA works on design optimization and degradation modeling of MAS, this work carried out an experimental validation for the developed FEA model, thus proving its practical applicability of simulating MAS degradation. Twelve stent samples of AZ31B were manufactured according to two MAS designs (an optimized one and a conventional one), with six samples of each design. All the samples were balloon expanded and subsequently immersed in D-Hanks' solution for a degradation test lasting 14 days. The experimental results showed that the samples of the optimized design had better corrosion resistance than those of the conventional design. Furthermore, the degradation process of the samples was dominated by uniform and stress corrosion. With the good match between the simulation and the experimental results, the work shows that the FEA numerical modeling constitutes an effective tool for design and thus the improvement of novel biodegradable MAS.
Collapse
|
534
|
Ostrowski N, Lee B, Enick N, Carlson B, Kunjukunju S, Roy A, Kumta PN. Corrosion protection and improved cytocompatibility of biodegradable polymeric layer-by-layer coatings on AZ31 magnesium alloys. Acta Biomater 2013; 9:8704-13. [PMID: 23684762 DOI: 10.1016/j.actbio.2013.05.010] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Revised: 04/17/2013] [Accepted: 05/08/2013] [Indexed: 10/26/2022]
Abstract
Composite coatings of electrostatically assembled layer-by-layer anionic and cationic polymers combined with an Mg(OH)2 surface treatment serve to provide a protective coating on AZ31 magnesium alloy substrates. These ceramic conversion coating and layer-by-layer polymeric coating combinations reduced the initial and long-term corrosion progression of the AZ31 alloy. X-ray diffraction and Fourier transform infrared spectroscopy confirmed the successful application of coatings. Potentiostatic polarization tests indicate improved initial corrosion resistance. Hydrogen evolution measurements over a 2 week period and magnesium ion levels over a 1 week period indicate longer range corrosion protection and retention of the Mg(OH)2 passivation layer in comparison to the uncoated substrates. Live/dead staining and DNA quantification were used as measures of biocompatibility and proliferation while actin staining and scanning electron microscopy were used to observe the cellular morphology and integration with the coated substrates. The coatings simultaneously provided improved biocompatibility, cellular adhesion and proliferation in comparison to the uncoated alloy surface utilizing both murine pre-osteoblast MC3T3 cells and human mesenchymal stem cells. The implementation of such coatings on magnesium alloy implants could serve to improve the corrosion resistance and cellular integration of these implants with the native tissue while delivering vital drugs or biological elements to the site of implantation.
Collapse
|
535
|
Doepke A, Kuhlmann J, Guo X, Voorhees RT, Heineman WR. A system for characterizing Mg corrosion in aqueous solutions using electrochemical sensors and impedance spectroscopy. Acta Biomater 2013; 9:9211-9. [PMID: 23871945 DOI: 10.1016/j.actbio.2013.07.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Revised: 07/08/2013] [Accepted: 07/09/2013] [Indexed: 11/28/2022]
Abstract
Understanding Mg corrosion is important to the development of biomedical implants made from Mg alloys. Mg corrodes readily in aqueous environments, producing H2, OH- and Mg2+. The rate of formation of these corrosion products is especially important in biomedical applications where they can affect cells and tissue near the implant. We have developed a corrosion characterization system (CCS) that allows realtime monitoring of the solution soluble corrosion products OH-, Mg2+, and H2 during immersion tests commonly used to study the corrosion of Mg materials. Instrumentation was developed to allow the system to also record electrochemical impedance spectra simultaneously in the same solution to monitor changes in the Mg samples. We demonstrated application of the CCS by observing the corrosion of Mg (99.9%) in three different corrosion solutions: NaCl, HEPES buffer, and HEPES buffer with NaCl at 37°C for 48 h. The solution concentrations of the corrosion products measured by sensors correlated with the results using standard weight loss measurements to obtain corrosion rates. This novel approach gives a better understanding of the dynamics of the corrosion process in realtime during immersion tests, rather than just providing a corrosion rate at the end of the test, and goes well beyond the immersion tests that are commonly used to study the corrosion of Mg materials. The system has the potential to be useful in systematically testing and comparing the corrosion behavior of different Mg alloys, as well as protective coatings.
Collapse
|
536
|
In vitro degradation and biocompatibility of Fe-Pd and Fe-Pt composites fabricated by spark plasma sintering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 35:43-53. [PMID: 24411350 DOI: 10.1016/j.msec.2013.10.023] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Revised: 10/12/2013] [Accepted: 10/21/2013] [Indexed: 11/23/2022]
Abstract
In order to obtain biodegradable Fe-based materials with similar mechanical properties as 316L stainless steel and faster degradation rate than pure iron, Fe-5 wt.%Pd and Fe-5 wt.%Pt composites were prepared by spark plasma sintering with powders of pure Fe and Pd/Pt, respectively. The grain size of Fe-5 wt.%Pd and Fe-5 wt.%Pt composites was much smaller than that of as-cast pure iron. The metallic elements Pd and Pt were uniformly distributed in the matrix and the mechanical properties of these materials were improved. Uniform corrosion of Fe-Pd and Fe-Pt composites was observed in both electrochemical tests and immersion tests, and the degradation rates of Fe-Pd and Fe-Pt composites were much faster than that of pure iron. It was found that viabilities of mouse fibroblast L-929 cells and human umbilical vein endothelial cells (ECV304) cultured in extraction mediums of Fe-Pd and Fe-Pt composites were close to that of pure iron. After 4 days' culture, the viabilities of L-929 and ECV304 cells in extraction medium of experimental materials were about 80%. The result of direct contact cytotoxicity also indicated that experimental materials exhibited no inhibition on vascular endothelial process. Meanwhile, iron ions released from experimental materials could inhibit proliferation of vascular smooth muscle cells (VSMC), which may be beneficial for hindering vascular restenosis. Furthermore, compared with that of as-cast pure iron, the hemolysis rates of Fe-Pd and Fe-Pt composites were slightly higher, but still within the range of 5%, which is the criteria for good blood compatibility. The numbers of platelet adhered on the surface of Fe-Pd and Fe-Pt composites were lower than that of pure iron, and the morphology of platelets kept spherical. To sum up, the Fe-5 wt.%Pd and Fe-5 wt.%Pt composites exhibited good mechanical properties and degradation behavior, closely approaching the requirements for biodegradable metallic stents.
Collapse
|
537
|
Stipanicev M, Turcu F, Esnault L, Rosas O, Basseguy R, Sztyler M, Beech IB. Corrosion of carbon steel by bacteria from North Sea offshore seawater injection systems: laboratory investigation. Bioelectrochemistry 2013; 97:76-88. [PMID: 24169516 DOI: 10.1016/j.bioelechem.2013.09.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 09/17/2013] [Accepted: 09/25/2013] [Indexed: 11/29/2022]
Abstract
Influence of sulfidogenic bacteria, from a North Sea seawater injection system, on the corrosion of S235JR carbon steel was studied in a flow bioreactor; operating anaerobically for 100days with either inoculated or filtrated seawater. Deposits formed on steel placed in reactors contained magnesium and calcium minerals plus iron sulfide. The dominant biofilm-forming organism was an anaerobic bacterium, genus Caminicella, known to produce hydrogen sulfide and carbon dioxide. Open Circuit Potentials (OCP) of steel in the reactors was, for nearly the entire test duration, in the range -800<E(OCP)/mV (vs. SCE)<-700. Generally, the overall corrosion rate, expressed as 1/(Rp/Ω), was lower in the inoculated seawater though they varied significantly on both reactors. Initial and final corrosion rates were virtually identical, namely initial 1/(Rp/Ω)=2×10(-6)±5×10(-7) and final 1/(Rp/Ω)=1.1×10(-5)±2.5×10(-6). Measured data, including electrochemical noise transients and statistical parameters (0.05<Localized Index<1; -5<Skewness<-5; Kurtosis>45), suggested pitting on steel samples within the inoculated environment. However, the actual degree of corrosion could neither be directly correlated with the electrochemical data and nor with the steel corrosion in the filtrated seawater environment. Further laboratory tests are thought to clarify the noticed apparent discrepancies.
Collapse
|
538
|
Liang L, Yang W, Guan X, Li J, Xu Z, Wu J, Huang Y, Zhang X. Kinetics and mechanisms of pH-dependent selenite removal by zero valent iron. WATER RESEARCH 2013; 47:5846-5855. [PMID: 23899877 DOI: 10.1016/j.watres.2013.07.011] [Citation(s) in RCA: 113] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2013] [Revised: 06/29/2013] [Accepted: 07/06/2013] [Indexed: 06/02/2023]
Abstract
The kinetics of Se(IV) removal by zero valent iron (ZVI) open to the air as a function of pH and the involved mechanisms were investigated in this study. The specific rate constants of Se(IV) removal by ZVI decreased from 92.87 to 6.87 L h(-1) m(-2) as pH increased from 4.0 to 7.0. The positive correlation between the removal rate of Se(IV) and the generation rate of Fe(II) and the depression of Se(IV) removal in the presence of 1,10-phenanthroline indicated that both ZVI and adsorbed Fe(II) on ZVI surface contributed to the reductive removal of Se(IV). The soft X-ray STXM measurement confirmed the adsorption of Fe(II) on the surface of ZVI and freshly formed ferric (hydr)oxides. Se(IV) was removed by adsorption followed by reduction to Se(0) on ZVI surface at pH 4.0-7.0, as revealed by XANES spectra. A core-shell structure was observed when ZVI reacted with Se(IV)-containing solution for 3 h at pH 6.0. Se(IV) was reduced to Se(0) and co-precipitated with the freshly formed Fe(III), forming the shell surrounding the iron core. After reaction for 24 h, the generated Se(0) was surrounded by multiple layers of Fe(III) oxides/hydroxides. SEM images and XRD patterns revealed that the corrosion products of ZVI at pH 6.0 transformed from amorphous iron hydroxides to lepidocrocite (γ-FeOOH) as reaction proceeded. The final corrosion products of ZVI contained both lepidocrocite and goethite at pH 5.0 while they were X-ray amorphous at pH 4.0 and 7.0.
Collapse
|
539
|
Pikaar I, Rozendal RA, Rabaey K, Yuan Z. In-situ caustic generation from sewage: the impact of caustic strength and sewage composition. WATER RESEARCH 2013; 47:5828-5835. [PMID: 23938119 DOI: 10.1016/j.watres.2013.07.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 06/21/2013] [Accepted: 07/05/2013] [Indexed: 06/02/2023]
Abstract
Periodic caustic dosage is a commonly used method by the water industry to elevate pH levels and deactivate sewer biofilms responsible for hydrogen sulfide generation. Caustic (NaOH) can be generated in-situ from sewage using a divided electrochemical cell, which avoids the need for transport, handling and storage of concentrated caustic solutions. In this study, we investigated the impact of caustic strength in the cathode compartment and the impact of sodium concentration in sewage on the Coulombic efficiency (CE) for caustic generation. The CE was found to be independent of the caustic strength produced in the range of up to ~3 wt%. Results showed that a caustic solution of ~3 wt% could be produced directly from sewage at a CE of up to 75 ± 0.5%. The sodium concentration in sewage had a significant impact on the CE for caustic generation as well as on the energy requirements of the system, with a higher sodium concentration leading to a higher CE and lower energy consumption. The proton, calcium, magnesium and ammonium concentrations in sewage affected the CE for caustic generation, especially at low sodium concentrations. Economical assessment based on the experimental results indicated that sulfide control in sewers using electrochemically-generated caustic from sewage is an economically attractive strategy.
Collapse
|
540
|
Chen H, Zhang E, Yang K. Microstructure, corrosion properties and bio-compatibility of calcium zinc phosphate coating on pure iron for biomedical application. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 34:201-6. [PMID: 24268250 DOI: 10.1016/j.msec.2013.09.010] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2013] [Revised: 08/19/2013] [Accepted: 09/09/2013] [Indexed: 01/08/2023]
Abstract
In order to improve the biocompatibility and the corrosion resistance in the initial stage of implantation, a phosphate (CaZn2(PO4)2·2H2O) coating was obtained on the surface of pure iron by a chemical reaction method. The anti-corrosion property, the blood compatibility and the cell toxicity of the coated pure iron specimens were investigated. The coating was composed of some fine phosphate crystals and the surface of coating was flat and dense enough. The electrochemical data indicated that the corrosion resistance of the coated pure iron was improved with the increase of phosphating time. When the specimen was phosphated for 30min, the corrosion resistance (Rp) increased to 8006 Ω. Compared with that of the naked pure iron, the anti-hemolysis property and cell compatibility of the coated specimen was improved significantly, while the anti-coagulant property became slightly worse due to the existence of element calcium. It was thought that phosphating treatment might be an effective method to improve the biocompatibility of pure iron for biomedical application.
Collapse
|
541
|
Peng CY, Ferguson JF, Korshin GV. Effects of chloride, sulfate and natural organic matter (NOM) on the accumulation and release of trace-level inorganic contaminants from corroding iron. WATER RESEARCH 2013; 47:5257-5269. [PMID: 23863395 DOI: 10.1016/j.watres.2013.06.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Revised: 05/23/2013] [Accepted: 06/02/2013] [Indexed: 06/02/2023]
Abstract
This study examined effects of varying levels of anions (chloride and sulfate) and natural organic matter (NOM) on iron release from and accumulation of inorganic contaminants in corrosion scales formed on iron coupons exposed to drinking water. Changes of concentrations of sulfate and chloride were observed to affect iron release and, in lesser extent, the retention of representative inorganic contaminants (vanadium, chromium, nickel, copper, zinc, arsenic, cadmium, lead and uranium); but, effects of NOM were more pronounced. DOC concentration of 1 mg/L caused iron release to increase, with average soluble and total iron concentrations being four and two times, respectively, higher than those in the absence of NOM. In the presence of NOM, the retention of inorganic contaminants by corrosion scales was reduced. This was especially prominent for lead, vanadium, chromium and copper whose retention by the scales decreased from >80% in the absence of NOM to <30% in its presence. Some of the contaminants, notably copper, chromium, zinc and nickel retained on the surface of iron coupons in the presence of DOC largely retained their mobility and were released readily when ambient water chemistry changed. Vanadium, arsenic, cadmium, lead and uranium retained by the scales were largely unsusceptible to changes of NOM and chloride levels. Modeling indicated that the observed effects were associated with the formation of metal-NOM complexes and effects of NOM on the sorption of the inorganic contaminants on solid phases that are typical for iron corrosion in drinking water.
Collapse
|
542
|
Gao Y, Korshin G. Effects of NOM properties on copper release from model solid phases. WATER RESEARCH 2013; 47:4843-4852. [PMID: 23850209 DOI: 10.1016/j.watres.2013.04.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 04/26/2013] [Accepted: 04/29/2013] [Indexed: 06/02/2023]
Abstract
This study examined impacts of concentrations and properties of natural organic matter (NOM) on copper release from characteristic copper solid model phases such as tenorite CuO and malachite Cu2(OH)2CO3. Unaltered Aldrich humic acid (AHA) and standard Suwannee River fulvic acid (SRFA) strongly increased copper release from the model phases but NOM alteration by chlorination or ozonation gradually suppressed or, at higher oxidant doses, eliminated these effects. The nature of NOM changes induced by chlorination and ozonation was examined using differential absorbance spectroscopy (DAS) and high-performance size-exclusion chromatography (HPSEC). The data of these methods show that NOM molecules with higher apparent molecular weight (AMW), higher aromaticities and contributions of protonation-active phenolic and carboxylic groups play a key role in adsorption and colloidal dispersion of the model solids. The data also show that metal release from model phases was well correlated with a number of spectroscopic parameters characterizing NOM properties, notably SUVA254, spectral slopes of NOM absorbance, and differential absorbance at wavelength of 280 nm and 350 nm that is indicative of the contributions of carboxylic and phenolic functional groups. Changes of ζ-potential of the model solid phases were the strongest predictor of the enhancement of copper release especially in the system controlled by malachite. While effects of NOM on the ζ-potential of tenorite and malachite were prominent for unaltered NOM, its oxidation by chlorine and ozone was accompanied by a gradual decrease and ultimately disappearance of its surface activity.
Collapse
|
543
|
Zigman T, Davila S, Dobric I, Antoljak T, Augustin G, Rajacic D, Kovac T, Ehrenfreund T. Intraoperative measurement of bone electrical potential: a piece in the puzzle of understanding fracture healing. Injury 2013; 44 Suppl 3:S16-9. [PMID: 24060011 DOI: 10.1016/s0020-1383(13)70191-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Bone electrical potentials change with the force applied. Also, fracture alters the bone electrical potential, so it becomes more electronegative. These potentials have an important role in fracture healing, bone growth and remodelling. Literature data on the influence of fracture operative treatment on bone electrical potentials, and possible consequences of this influence, are sparse. The objective of this study was to establish a method of intraoperative bone potential measurement, and to try to find a correlation between electrical potential and fracture type, osteosynthesis method and prognosis. PATIENTS AND METHODS 52 patients with a pertrochanteric fracture were included in the study. Bone electrical potentials were measured intraoperatively using a thin Kirschner wire introduced through bone cortex at the selected point and pointed to opposite cortex, not penetrating it. Kirschner wires were connected using clamps to multimeter (YF-78 Multimeter) device. Neutral electrode (inductive rubber) was placed behind ipsilateral gluteus. RESULTS Near the fracture site potentials of -199 up to -267 mV were recorded. Mean measured potential of bone plate after fixation was -240 mV. Bone potentials correlated with the subtype of fracture and early mobilisation of patients. CONCLUSIONS Bone potentials, caused by fracture, can be measured intraoperatively; the operative procedure appears to influence their generation. Measured potentials depend on the fracture type, and could be correlated with prognosis.
Collapse
|
544
|
Wogan ME, Webster-Hoffmeyer KS, Grgicak CM. Corrosion behaviour of four handguns in aqueous environments: corrosion product characterization and effects on estimating the time since deposition. Sci Justice 2013; 53:363-70. [PMID: 23937948 DOI: 10.1016/j.scijus.2013.04.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2012] [Revised: 04/25/2013] [Accepted: 04/30/2013] [Indexed: 10/26/2022]
Abstract
When a firearm has been disposed of in a body of water and becomes corroded, its appearance is altered and determining a time-since-immersion may be of import to the investigation. Therefore, in this study, the corrosion and mass loss of four handgun slides over a period of 180days were examined. Solid-state characterization of the metals and their corrosion products via SEM/EDX and powder X-ray Diffraction (pXRD) was performed. The pXRDs were analyzed against the NIST Powder Diffraction Database to determine the crystalline phases. Filings from the SS416 standard, Llama and Ruger handgun slide predominantly consisted of iron alloys. After 180-days in solution, pXRD indicated that the adherent corrosion products consisted of 1) γ-FeOOH and 2) iron oxide (Fe3O4 or Fe2O3). Additionally, pXRD analysis indicated that the adherent corrosion products of the SS416 standard also consisted of CrO3. Metal filings from the Raven and Jennings handgun slides were a mixture of iron-nickel-zinc and EDX and pXRD analyses of the corrosion products, when submersed in deionized water, indicated that the products consisted of: 1) γ-FeOOH, 2) iron oxide (Fe3O4 or Fe2O3), and 3) ZnFe2O4 or ZnO; where the Jennings adherent rust contained ZnFe2O4 and the Raven adherent rust contained ZnO. Further, pXRD of the corrosion products from these alloys, when submersed in 25 PSU (Practical Salinity Unit) solution, indicated that the products consisted of: 1) ZnO, 2) Zn(OH)2, 3) α-Ni(OH)2, and 4) NaCl. The data thus indicated that both metal composition and the presence of chloride ions had significant impacts on rates and products of corrosion and suggest that the presence of Cl(-) changes not only the rate of corrosion, but also the corroding species itself. While mechanisms and rates of the chloride driven corrosion processes offer explanations as to the different oxides and hydroxides observed between immersion conditions, they do not offer an explanation for the differences observed between handguns. Therefore, utilizing a general approach where surface area coverage of corrosion products is the sole consideration is not sufficient to determine time-since-immersion. Attempts to determine a time-since-immersion would require a priori knowledge of the mechanism of corrosion for a given metal mixture within a specified environment. The results described herein give indications as to the possible corrosion mechanism driving the process in high and low Cl(-) environments and show the necessity of including the metal composition, rust composition and ion concentration in any models that attempt to elucidate the time-since-immersion of handguns for forensic applications.
Collapse
|
545
|
Talha M, Behera CK, Sinha OP. A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:3563-75. [PMID: 23910251 DOI: 10.1016/j.msec.2013.06.002] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2012] [Revised: 05/30/2013] [Accepted: 06/04/2013] [Indexed: 10/26/2022]
Abstract
The field of biomaterials has become a vital area, as these materials can enhance the quality and longevity of human life. Metallic materials are often used as biomaterials to replace structural components of the human body. Stainless steels, cobalt-chromium alloys, commercially pure titanium and its alloys are typical metallic biomaterials that are being used for implant devices. Stainless steels have been widely used as biomaterials because of their very low cost as compared to other metallic materials, good mechanical and corrosion resistant properties and adequate biocompatibility. However, the adverse effects of nickel ions being released into the human body have promoted the development of "nickel-free nitrogen containing austenitic stainless steels" for medical applications. Nitrogen not only replaces nickel for austenitic structure stability but also much improves steel properties. Here we review the harmful effects associated with nickel and emphatically the advantages of nitrogen in stainless steel, as well as the development of nickel-free nitrogen containing stainless steels for medical applications. By combining the benefits of stable austenitic structure, high strength, better corrosion and wear resistance and superior biocompatibility in comparison to the currently used austenitic stainless steel (e.g. 316L), the newly developed nickel-free high nitrogen austenitic stainless steel is a reliable substitute for the conventionally used medical stainless steels.
Collapse
|
546
|
Cui WF, Jin L, Zhou L. Surface characteristics and electrochemical corrosion behavior of a pre-anodized microarc oxidation coating on titanium alloy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:3775-9. [PMID: 23910276 DOI: 10.1016/j.msec.2013.05.011] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2012] [Revised: 02/12/2013] [Accepted: 05/03/2013] [Indexed: 10/26/2022]
Abstract
A porous bioactive titania coating on biomedical β titanium alloy was prepared by pre-anodization followed by micro arc oxidation technology. The effects of pre-anodization on the phase constituent, morphology and electrochemical corrosion behavior of the microarc oxidation coating were investigated. The results show that pre-anodization has less influence on the phase constituent and the surface morphology of the microarc oxidation coating, but improves the inner layer density of the microarc oxidation coating. The decrease of plasma discharge strength due to the presence of the pre-anodized oxide film contributes to the formation of the compact inner layer. The pre-anodized microarc oxidation coating effectively inhibits the penetration of the electrolyte in 0.9% NaCl solution and thus increases the corrosion resistance of the coated titanium alloy in physiological solution.
Collapse
|
547
|
Zhou WR, Zheng YF, Leeflang MA, Zhou J. Mechanical property, bio corrosion and in vitro biocompatibility evaluations of Mg-Li-(Al)-(RE) alloys for future cardiovascular stent application. Acta Biomater 2013. [PMID: 23385218 DOI: 10.1016/j.actbio.2013.01.032.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Mg-Li-based alloys were investigated for future cardiovascular stent application as they possess excellent ductility. However, Mg-Li binary alloys exhibited reduced mechanical strengths due to the presence of lithium. To improve the mechanical strengths of Mg-Li binary alloys, aluminum and rare earth (RE) elements were added to form Mg-Li-Al ternary and Mg-Li-Al-RE quarternary alloys. In the present study, six Mg-Li-(Al)-(RE) alloys were fabricated. Their microstructures, mechanical properties and biocorrosion behavior were evaluated by using optical microscopy, X-ray diffraction, scanning electronic microscopy, tensile tests, immersion tests and electrochemical measurements. Microstructure characterization indicated that grain sizes were moderately refined by the addition of rare earth elements. Tensile testing showed that enhanced mechanical strengths were obtained, while electrochemical and immersion tests showed reduced corrosion resistance caused by intermetallic compounds distributed throughout the magnesium matrix in the rare-earth-containing Mg-Li alloys. Cytotoxicity assays, hemolysis tests as well as platelet adhesion tests were performed to evaluate in vitro biocompatibilities of the Mg-Li-based alloys. The results of cytotoxicity assays clearly showed that the Mg-3.5Li-2Al-2RE, Mg-3.5Li-4Al-2RE and Mg-8.5Li-2Al-2RE alloys suppressed vascular smooth muscle cell proliferation after 5day incubation, while the Mg-3.5Li, Mg-8.5Li and Mg-8.5Li-1Al alloys were proven to be tolerated. In the case of human umbilical vein endothelial cells, the Mg-Li-based alloys showed no significantly reduced cell viabilities except for the Mg-8.5Li-2Al-2RE alloy, with no obvious differences in cell viability between different culture periods. With the exception of Mg-8.5Li-2Al-2RE, all of the other Mg-Li-(Al)-(RE) alloys exhibited acceptable hemolysis ratios, and no sign of thrombogenicity was found. These in vitro experimental results indicate the potential of Mg-Li-(Al)-(RE) alloys as biomaterials for future cardiovascular stent application and the worthiness of investigating their biodegradation behaviors in vivo.
Collapse
|
548
|
Kim JH, Cha JY, Hwang CJ. In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets. Korean J Orthod 2013; 42:297-306. [PMID: 23323244 PMCID: PMC3542450 DOI: 10.4041/kjod.2012.42.6.297] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2012] [Revised: 06/22/2012] [Accepted: 08/02/2012] [Indexed: 11/18/2022] Open
Abstract
Objective This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. Methods Four bracket brands were tested for dimensional accuracy, (manufacturing errors in angulation and torque), cytotoxicity, composition, elution, and corrosion: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). Results The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. Conclusions The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.
Collapse
|
549
|
Vijayaraghavan V, Sabane AV, Tejas K. Hypersensitivity to titanium: a less explored area of research. J Indian Prosthodont Soc 2012; 12:201-7. [PMID: 24293916 PMCID: PMC3508103 DOI: 10.1007/s13191-012-0139-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2012] [Accepted: 06/22/2012] [Indexed: 11/29/2022] Open
Abstract
Titanium is considered as an excellent biocompatible metal and it is used in implant dentistry. Literature suggests that Ti can induce clinically relevant hypersensitivity and other immune dysfunctions in certain patients chronically exposed to this reactive metal. At the same time, no standard patch test for Ti has so far been developed, and positive reactions to Ti have therefore only rarely been demonstrated with skin testing. This article reports about the corrosion of dental implants, their significance when hypersensitivity is present, and the literature available till date regarding hypersensitivity of titanium.
Collapse
|
550
|
Hussein MHM, El-Hady MF, Shehata HAH, Hegazy MA, Hefni HHH. Preparation of Some Eco-friendly Corrosion Inhibitors Having Antibacterial Activity from Sea Food Waste. J SURFACTANTS DETERG 2012; 16:233-242. [PMID: 23420292 PMCID: PMC3573188 DOI: 10.1007/s11743-012-1395-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2012] [Accepted: 07/17/2012] [Indexed: 10/31/2022]
Abstract
Chitosan is one of the important biopolymers and it is extracted from exoskeletons of crustaceans in sea food waste. It is a suitable eco-friendly carbon steel corrosion inhibitor in acid media; the deacetylation degree of prepared chitosan is more than 85.16 %, and the molecular weight average is 109 kDa. Chitosan was modified to 2-N,N-diethylbenzene ammonium chloride N-oxoethyl chitosan (compound I), and 12-ammonium chloride N-oxododecan chitosan (compound II) as soluble water derivatives. The corrosion inhibition efficiency for carbon steel of compound (I) in 1 M HCl at varying temperature is higher than for chitosan and compound (II). However, the antibacterial activity of chitosan for Enterococcus faecalis, Escherichia coli, Staphylococcus aureus, and Candida albicans is higher than for its derivatives, and the minimum inhibition concentration and minimum bacterial concentration of chitosan and its derivatives were carried out with the same strain.
Collapse
|