51
|
Gades NM, Jacobson DJ, McGree ME, St Sauver JL, Lieber MM, Nehra A, Girman CJ, Klee GG, Jacobsen SJ. The associations between serum sex hormones, erectile function, and sex drive: the Olmsted County Study of Urinary Symptoms and Health Status among Men. J Sex Med 2008; 5:2209-20. [PMID: 18624959 DOI: 10.1111/j.1743-6109.2008.00924.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
INTRODUCTION Testosterone replacement therapy has been used in the treatment of sexual dysfunction; however, its use remains controversial, and the effectiveness and long-term health implications are unknown. AIM To evaluate the association between sex hormone serum levels, erectile function, and sexual drive in a population-based sample of men. METHODS A stratified random sample of men residing in Olmsted County, Minnesota, completed a questionnaire containing questions from the Brief Male Sexual Function Inventory (BMSFI), and participated in a clinical exam, which included serum hormone measurements. MAIN OUTCOME MEASURES Levels of sexual drive (libido) and erectile function as assessed by the BMSFI and serum testosterone, bioavailable testosterone, and estradiol measurements. RESULTS Out of 414 men, 294 had a regular sexual partner and androgen measurements at the 14th year of follow-up. Total testosterone and erectile function were significantly correlated even after adjustment for age (r = 0.12, P = 0.04). Conversely, total testosterone was not significantly correlated with sex drive (r = 0.08, P = 0.17). Bioavailable testosterone was significantly correlated with both erectile function and sex drive (r = 0.16, P = 0.01 and r = 0.20, P = 0.001, respectively). However, these associations disappeared after age adjustment (r = 0.04 and r = 0.09). CONCLUSIONS These cross-sectional results suggest the relationship between sex hormones and sexual function is complex, and that the age-related decline in sexual function may be due to age-related declines in levels of bioavailable testosterone rather than total testosterone levels.
Collapse
|
52
|
Nakagawa T, Kollmeyer TM, Morlan BW, Anderson SK, Bergstralh EJ, Davis BJ, Asmann YW, Klee GG, Ballman KV, Jenkins RB. A tissue biomarker panel predicting systemic progression after PSA recurrence post-definitive prostate cancer therapy. PLoS One 2008; 3:e2318. [PMID: 18846227 PMCID: PMC2565588 DOI: 10.1371/journal.pone.0002318] [Citation(s) in RCA: 146] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2007] [Accepted: 03/12/2008] [Indexed: 12/14/2022] Open
Abstract
Background Many men develop a rising PSA after initial therapy for prostate cancer. While some of these men will develop a local or metastatic recurrence that warrants further therapy, others will have no evidence of disease progression. We hypothesized that an expression biomarker panel can predict which men with a rising PSA would benefit from further therapy. Methodology/Principal Findings A case-control design was used to test the association of gene expression with outcome. Systemic (SYS) progression cases were men post-prostatectomy who developed systemic progression within 5 years after PSA recurrence. PSA progression controls were matched men post-prostatectomy with PSA recurrence but no evidence of clinical progression within 5 years. Using expression arrays optimized for paraffin-embedded tissue RNA, 1021 cancer-related genes were evaluated–including 570 genes implicated in prostate cancer progression. Genes from 8 previously reported marker panels were included. A systemic progression model containing 17 genes was developed. This model generated an AUC of 0.88 (95% CI: 0.84–0.92). Similar AUCs were generated using 3 previously reported panels. In secondary analyses, the model predicted the endpoints of prostate cancer death (in SYS cases) and systemic progression beyond 5 years (in PSA controls) with hazard ratios 2.5 and 4.7, respectively (log-rank p-values of 0.0007 and 0.0005). Genes mapped to 8q24 were significantly enriched in the model. Conclusions/Significance Specific gene expression patterns are significantly associated with systemic progression after PSA recurrence. The measurement of gene expression pattern may be useful for determining which men may benefit from additional therapy after PSA recurrence.
Collapse
|
53
|
Gerszten RE, Accurso F, Bernard GR, Caprioli RM, Klee EW, Klee GG, Kullo I, Laguna TA, Roth FP, Sabatine M, Srinivas P, Wang TJ, Ware LB. Challenges in translating plasma proteomics from bench to bedside: update from the NHLBI Clinical Proteomics Programs. Am J Physiol Lung Cell Mol Physiol 2008; 295:L16-22. [PMID: 18456800 DOI: 10.1152/ajplung.00044.2008] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The emerging scientific field of proteomics encompasses the identification, characterization, and quantification of the protein content or proteome of whole cells, tissues, or body fluids. The potential for proteomic technologies to identify and quantify novel proteins in the plasma that can function as biomarkers of the presence or severity of clinical disease states holds great promise for clinical use. However, there are many challenges in translating plasma proteomics from bench to bedside, and relatively few plasma biomarkers have successfully transitioned from proteomic discovery to routine clinical use. Key barriers to this translation include the need for "orthogonal" biomarkers (i.e., uncorrelated with existing markers), the complexity of the proteome in biological samples, the presence of high abundance proteins such as albumin in biological samples that hinder detection of low abundance proteins, false positive associations that occur with analysis of high dimensional datasets, and the limited understanding of the effects of growth, development, and age on the normal plasma proteome. Strategies to overcome these challenges are discussed.
Collapse
|
54
|
Rhodes T, McGree ME, Jacobson DJ, Girman CJ, St Sauver JL, Lieber MM, Klee GG, Jacobsen SJ. LONGITUDINAL CHANGES OF BENIGN PROSTATE SPECIFIC ANTIGEN AND PRO-PROSTATE SPECIFIC ANTIGEN OVER 8 YEARS AND THEIR RELATIONSHIP WITH LONGITUDINAL CHANGES IN UROLOGIC MEASURES IN A COMMUNITY-BASED SAMPLE OF MEN. J Urol 2008. [DOI: 10.1016/s0022-5347(08)61687-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
55
|
Sarma AV, Jacobson DJ, McGree ME, St Sauver JL, Rhodes T, Lieber MM, Klee GG, Jacobsen SJ. RACIAL DIFFERENCES IN SERUM BPSA AND [-2]proPSA CONCENTRATIONS: THE OLMSTED COUNTY STUDY OF URINARY SYMPTOMS AND HEALTH STATUS AMONG MEN AND THE FLINT MEN'S HEALTH STUDY. J Urol 2008. [DOI: 10.1016/s0022-5347(08)61691-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
56
|
Ellington AA, Malik AR, Klee GG, Kullo IJ. Response to Resistin, Glomerular Filtration Rate, and Insulin Resistance. Hypertension 2008. [DOI: 10.1161/hypertensionaha.107.102053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
57
|
Klee GG, Schryver PG, Saenger AK, Larson TS. Effects of analytic variations in creatinine measurements on the classification of renal disease using estimated glomerular filtration rate (eGFR). Clin Chem Lab Med 2008; 45:737-41. [PMID: 17579525 DOI: 10.1515/cclm.2007.168] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND This study uses the Isotope Dilution Mass Spectrometer-Traceable Modification of Diet in Renal Disease (MDRD) equation to evaluate the effects of analytic variation of serum creatinine on estimated glomerular filtration rate (eGFR). The equation was inverted to provide critical creatinine levels corresponding to eGFRs equal to 15, 30, and 60 mL/min/1.73 m(2). METHODS eGFRs were calculated for two populations of patients representing clinic outpatients and hospitalized inpatients. Simulation studies evaluated the effects of analytic bias for these populations. Differences between creatinine tests ordered on consecutive blood draws were analyzed for within-subject eGFR variation. Finally, propagation of error techniques established the relationship between creatinine imprecision and eGFR imprecision. RESULTS eGFR of 60 mL/min/1.73 m(2) corresponds to creatinine levels of 80-156 micromol/L. A 20-micromol/L negative shift of creatinine approximately doubles the percentage of patients classified in various stages of decreased renal function, whereas a positive shift approximately halves the percentage. The central 95% limits for within-subject variation of eGFR are 33% for outpatients, 38% for inpatients and 40% across the groups. eGFR imprecision is approximately 15%-20% higher than creatinine imprecision. CONCLUSIONS Small analytic changes in serum creatinine create major shifts in the distributions of eGFR, which can cause large differences in the classification of patients. The within-subject variations in eGFR over time, especially between hospital and clinic measurements, can be large. Therefore, tight control of laboratory analysis is important.
Collapse
|
58
|
Klee EW, Finlay JA, McDonald C, Attewell JR, Hebrink D, Dyer R, Love B, Vasmatzis G, Li TM, Beechem JM, Klee GG. Bioinformatics methods for prioritizing serum biomarker candidates. Clin Chem 2007; 52:2162-4. [PMID: 18061989 DOI: 10.1373/clinchem.2006.072868] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
59
|
Ellington AA, Malik AR, Klee GG, Turner ST, Rule AD, Mosley TH, Kullo IJ. Association of plasma resistin with glomerular filtration rate and albuminuria in hypertensive adults. Hypertension 2007; 50:708-14. [PMID: 17785630 DOI: 10.1161/hypertensionaha.107.095257] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Resistin, a recently discovered proinflammatory cytokine, has been variably associated with insulin resistance, inflammation, and renal dysfunction. We investigated the association of plasma resistin with estimated glomerular filtration rate and albuminuria in 1575 hypertensive adults without known coronary heart disease or stroke (857 blacks and 718 non-Hispanic whites). Resistin was measured by a solid phase sandwich immunoassay, estimated glomerular filtration rate was estimated from serum creatinine, and albuminuria was expressed as urine albumin:creatinine ratio. After adjustment for coronary heart disease risk factors (age, sex, body mass index, smoking history, systolic blood pressure, diabetes, and total and high-density lipoprotein cholesterol) and use of renin-angiotensin blockers and statins, higher plasma resistin levels were associated with lower estimated glomerular filtration rate in both ethnic groups (each P<0.0001); the association remained significant after further adjustment for a marker of insulin resistance (homeostasis model assessment for insulin resistance) and a marker of inflammation (plasma C-reactive protein) and was seen in subjects with and without diabetes (each P<0.0001) in both ethnic groups. Higher plasma resistin levels were associated with a higher urine albumin:creatinine ratio in black subjects with diabetes (P<0.0001) and non-Hispanic white subjects with diabetes (P=0.032), independent of coronary heart disease risk factors, hypertension medication use, and statin use; the association remained significant after additional adjustment for homeostasis model assessment for insulin resistance and C-reactive protein. In adults with hypertension, higher circulating resistin levels were associated with a lower estimated glomerular filtration rate and with increased urine albumin:creatinine ratio in the presence of concomitant diabetes. This association was independent of coronary heart disease risk factors and markers of insulin resistance and inflammation.
Collapse
|
60
|
Bondar OP, Barnidge DR, Klee EW, Davis BJ, Klee GG. LC-MS/MS Quantification of Zn-α2 Glycoprotein: A Potential Serum Biomarker for Prostate Cancer. Clin Chem 2007; 53:673-8. [PMID: 17317883 DOI: 10.1373/clinchem.2006.079681] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground: Zn-α2 glycoprotein (ZAG) is a relatively abundant glycoprotein that has potential as a biomarker for prostate cancer. We present a high-flow liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for measuring serum ZAG concentrations by proteolytic cleavage of the protein and quantification of a unique peptide.Methods: We selected the ZAG tryptic peptide 147EIPAWVPEDPAAQITK162 as the intact protein for quantification and used a stable isotope-labeled synthetic peptide with this sequence as an internal standard. Standards using recombinant ZAG in bovine serum albumin, 50 g/L, and a pilot series of patient sera were denatured, reduced, alkylated, and digested with trypsin. The concentration of ZAG was calculated from a dose–response curve of the ratio of the relative abundance of the ZAG tryptic peptide to internal standard.Results: The limit of detection for ZAG in serum was 0.08 mg/L, and the limit of quantification was 0.32 mg/L with a linear dynamic range of 0.32 to 10.2 mg/L. Replicate digests from pooled sera run during a period of 3 consecutive days showed intraassay imprecision (CV) of 5.0% to 6.3% and interassay imprecision of 4.4% to 5.9%. Mean (SD) ZAG was higher in 25 men with prostate cancer [7.59 (2.45) mg/L] than in 20 men with nonmalignant prostate disease [6.21 (1.65) mg/L, P = 0.037] and 6 healthy men [3.65 (0.71) mg/L, P = 0.0007].Conclusions: This LC-MS/MS assay is reproducible and can be used to evaluate the clinical utility of ZAG as a cancer biomarker.
Collapse
|
61
|
Finlay JA, Klee EW, McDonald C, Attewell JR, Hebrink D, Dyer R, Love B, Vasmatzis G, Li TM, Beechem JM, Klee GG. A Systematic Method for Selection of Promising Serum Protein Biomarkers to Improve Prostate Cancer (PCa1) Detection. Clin Chem 2006; 52:2159-62. [DOI: 10.1373/clinchem.2006.072959] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
62
|
Nair KS, Rizza RA, O'Brien P, Dhatariya K, Short KR, Nehra A, Vittone JL, Klee GG, Basu A, Basu R, Cobelli C, Toffolo G, Dalla Man C, Tindall DJ, Melton LJ, Smith GE, Khosla S, Jensen MD. DHEA in elderly women and DHEA or testosterone in elderly men. N Engl J Med 2006; 355:1647-59. [PMID: 17050889 DOI: 10.1056/nejmoa054629] [Citation(s) in RCA: 370] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Dehydroepiandrosterone (DHEA) and testosterone are widely promoted as antiaging supplements, but the long-term benefits, as compared with potential harm, are unknown. METHODS We performed a 2-year, placebo-controlled, randomized, double-blind study involving 87 elderly men with low levels of the sulfated form of DHEA and bioavailable testosterone and 57 elderly women with low levels of sulfated DHEA. Among the men, 29 received DHEA, 27 received testosterone, and 31 received placebo. Among the women, 27 received DHEA and 30 received placebo. Outcome measures included physical performance, body composition, bone mineral density (BMD), glucose tolerance, and quality of life. RESULTS As compared with the change from baseline to 24 months in the placebo group, subjects who received DHEA for 2 years had an increase in plasma levels of sulfated DHEA by a median of 3.4 microg per milliliter (9.2 micromol per liter) in men and by 3.8 microg per milliliter (10.3 micromol per liter) in women. Among men who received testosterone, the level of bioavailable testosterone increased by a median of 30.4 ng per deciliter (1.1 nmol per liter), as compared with the change in the placebo group. A separate analysis of men and women showed no significant effect of DHEA on body-composition measurements. Neither hormone altered the peak volume of oxygen consumed per minute, muscle strength, or insulin sensitivity. Men who received testosterone had a slight increase in fat-free mass, and men in both treatment groups had an increase in BMD at the femoral neck. Women who received DHEA had an increase in BMD at the ultradistal radius. Neither treatment improved the quality of life or had major adverse effects. CONCLUSIONS Neither DHEA nor low-dose testosterone replacement in elderly people has physiologically relevant beneficial effects on body composition, physical performance, insulin sensitivity, or quality of life. (ClinicalTrials.gov number, NCT00254371 [ClinicalTrials.gov].).
Collapse
|
63
|
Rana R, Vlahakis NE, Daniels CE, Jaffe AS, Klee GG, Hubmayr RD, Gajic O. B-type natriuretic peptide in the assessment of acute lung injury and cardiogenic pulmonary edema*. Crit Care Med 2006; 34:1941-6. [PMID: 16691132 DOI: 10.1097/01.ccm.0000220492.15645.47] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE The role of plasma B-type natriuretic peptide (BNP) in critically ill patients with acute pulmonary edema is controversial. We postulated that a low BNP level would exclude cardiac dysfunction as the principal cause of pulmonary edema and therefore help in the diagnosis of acute lung injury. DESIGN A retrospective derivation cohort was followed by a prospective validation cohort of consecutive patients with acute pulmonary edema admitted to three intensive care units. BNP was measured within 24 hrs from onset. Critical care experts blinded to BNP results integrated clinical data with the course of disease and response to therapy and served as the reference standard. SETTING Three intensive care units at the tertiary center. PATIENTS Consecutive critically ill patients with acute pulmonary edema. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS In a derivation cohort of 84 patients, a BNP threshold of <or=250 pg/mL had a specificity of 87% and sensitivity of 48% for the diagnosis of acute lung injury. High specificity of BNP (90%, likelihood ratio of 3.9) was confirmed in a validation cohort of 120 consecutive patients, 52 (43%) of whom had acute lung injury. Notably, 32% of patients with acute lung injury had concomitant cardiac dysfunction. The median time from the onset of pulmonary edema to BNP testing was 3 hrs. The accuracy of BNP (area under receiver operator curve, 0.71) was comparable with pulmonary artery occlusion pressure (area under receiver operator curve, 0.66) and superior to ejection fraction (area under receiver operator curve, 0.60) in subgroups of patients in whom these tests were performed. The accuracy of BNP improved when patients with renal insufficiency were excluded (area under receiver operator curve, 0.82). CONCLUSION When measured early after the onset of acute pulmonary edema, a BNP level of <250 pg/mL supports the diagnosis of acute lung injury. The high rate of cardiac and renal dysfunction in critically ill patients limits the discriminative role of BNP. No level of BNP could completely exclude cardiac dysfunction.
Collapse
|
64
|
Davis BJ, Klee GG, Burch PA, Hillman DW, Zhao C, Szumlanski CL, Young CY, Lieber MM, Blute ML, Tindall DJ. 861: Serum Human Glandular Kallikrein 2 and Pro-Human Glandular Kallikrein 2 Concentration Correlates with Survival in Patients with Hormone Refractory Prostate Cancer. J Urol 2006. [DOI: 10.1016/s0022-5347(18)33097-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
65
|
Klee GG, Killeen AA. College of American Pathologists 2003 fresh frozen serum proficiency testing studies. Arch Pathol Lab Med 2005; 129:292-3. [PMID: 15737018 DOI: 10.5858/2005-129-292-coapff] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
66
|
Steele BW, Wang E, Klee GG, Thienpont LM, Soldin SJ, Sokoll LJ, Winter WE, Fuhrman SA, Elin RJ. Analytic bias of thyroid function tests: analysis of a College of American Pathologists fresh frozen serum pool by 3900 clinical laboratories. Arch Pathol Lab Med 2005; 129:310-7. [PMID: 15737023 DOI: 10.5858/2005-129-310-abotft] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT In proficiency testing surveys, there are differences in the values reported by users of various analytic methods. Two contributors to this variation are calibrator bias and matrix effects of proficiency testing materials. OBJECTIVES (1) To quantify the biases of the analytic methods used to measure thyroid-stimulating hormone, thyroxine, triiodothyronine, free thyroxine, and free triiodothyronine levels; (2) to determine if these biases are within allowable limits; and (3) to ascertain if proficiency testing materials correctly identify these biases. DESIGN A fresh frozen serum specimen was mailed as part of the 2003 College of American Pathologists Ligand and Chemistry surveys. The means and SDs for each analytic method were determined for this sample as well as for a proficiency testing sample from both surveys. In the fresh frozen serum sample, target values for thyroxine and triiodothyronine were determined by isotope dilution/liquid chromatography/tandem mass spectrometry. All other target values in the study were the median of the means obtained for the various analytic methods. MAIN OUTCOME MEASURES Calibration biases were calculated by comparing the mean of each analytic method with the appropriate target values. These biases were evaluated against limits based on intra- and interindividual biological variation. Matrix effects of proficiency testing materials were assessed by comparing the rank of highest to lowest analytic method means (Spearman rank test) for each analyte. PARTICIPANTS Approximately 3900 clinical laboratories were enrolled in the College of American Pathologists Chemistry and Ligand surveys. RESULTS The number of methods in the Ligand Survey that failed to meet the goals for bias was 7 of 17 for thyroid-stimulating hormone and 11 of 13 for free thyroxine. The failure rates were 12 of 16 methods for thyroxine, 8 of 11 for triiodothyronine, and 9 of 11 for free triiodothyronine. The means of the analytic method for the proficiency testing material correlated significantly (P < .05) only with the fresh frozen serum means for thyroxine and thyroid-stimulating hormone in the Chemistry Survey and free triiodothyronine in the Ligand Survey. CONCLUSIONS A majority of the methods used in thyroid function testing have biases that limit their clinical utility. Traditional proficiency testing materials do not adequately reflect these biases.
Collapse
|
67
|
Bock JL, Endres DB, Elin RJ, Wang E, Rosenzweig B, Klee GG. Comparison of fresh frozen serum to traditional proficiency testing material in a College of American Pathologists survey for ferritin, folate, and vitamin B12. Arch Pathol Lab Med 2005; 129:323-7. [PMID: 15737025 DOI: 10.5858/2005-129-323-coffst] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT Comparison of different analytical methods in proficiency surveys may be affected by the artificial nature of the survey material. OBJECTIVE To compare intermethod differences in proficiency survey results between 2 types of survey material, conventional proficiency testing material (PTM) and fresh frozen human serum (FFS), for 3 markers of anemia: ferritin, folate, and vitamin B12. DESIGN Data were gathered from a 2003 survey event in the College of American Pathologists Ligand ("K") Series, in which the specimens to be tested by each participating laboratory included 1 vial of FFS and 2 vials of PTM with different analyte concentrations. The more than 1600 laboratories subscribing to the survey were not advised as to the nature of the specimens. MAIN OUTCOME MEASURES The bias of each method relative to the median of method means for each analyte and each type of survey material, and the interlaboratory coefficient of variation for each method. RESULTS For each of the 3 analytes, moderate to large method biases were observed. For ferritin, method biases correlated strongly between comparable PTM and FFS specimens (Spearman r = 0.863, P < .001), whereas virtually no correlation was found for folate (r = -0.224, P = .48), and a marginally significant correlation existed for B12 (r = 0.55, P = .049). CONCLUSIONS With ferritin, proficiency survey performance of PTM is similar to that of FFS, implying that method biases relate mainly to calibration. With folate and to a lesser extent with B12, PTM and FFS exhibit different method biases, implying that the biases reflect analyte heterogeneity and/or matrix effects.
Collapse
|
68
|
Klee GG, Schreiber WE. MUC1 gene-derived glycoprotein assays for monitoring breast cancer (CA 15-3, CA 27.29, BR): are they measuring the same antigen? Arch Pathol Lab Med 2005; 128:1131-5. [PMID: 15387710 DOI: 10.5858/2004-128-1131-mggafm] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT There are 2 general types of assays measuring MUC1 gene-derived glycoprotein: assays for cancer antigen (CA) 15-3, which are sandwich assays, and assays for CA 27.29, which are competitive assays. These 2 types of assays measure slightly different parts of this tandem-repeat molecule. Across-method assay differences hinder the exchange of patient test values among integrated health care networks and among countries. OBJECTIVE This report evaluates the method differences among these assays to determine if the differences between these assays are mainly related to variations in calibration or differences in analyte specificity. DESIGN Data from 22 College of American Pathologists survey challenges were analyzed to compare 10 commercial assay methods for these 2 related analytes. In addition, data from 58 patient samples were analyzed to compare 3 of these assays. RESULTS The linear correlation coefficients comparing the within-method medians of these proficiency test distributions were very high (>0.99) for all of the methods; however, the regression slopes varied from 0.836 to 1.095. The regression slopes for the patient specimens varied similarly, but the correlation coefficients were lower. CONCLUSIONS This study indicates that many of the test value differences for these measurements are due to differences in assay calibration rather than differences in the specificity of the assay measurement systems. Survey test data potentially could be used to help harmonize these assay differences.
Collapse
|
69
|
Steele BW, Wang E, Palmer-Toy DE, Killeen AA, Elin RJ, Klee GG. Total Long-term Within-Laboratory Precision of Cortisol, Ferritin, Thyroxine, Free Thyroxine, and Thyroid-Stimulating Hormone Assays Based on a College of American Pathologists Fresh Frozen Serum Study: Do Available Methods Meet Medical Needs for Precision? Arch Pathol Lab Med 2005; 129:318-22. [PMID: 15737024 DOI: 10.5858/2005-129-318-tlwpoc] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractContext.—It is important that the total long-term precision of laboratory methods meet the medical needs of the patients being served.Objectives.—To determine the long-term within- and between-laboratory variation of cortisol, ferritin, thyroxine, free thyroxine, and thyroid-stimulating hormone measurements using commonly available methods and to determine if these variations are within accepted medical needs.Design.—Two vials of pooled frozen serum were mailed 6 months apart to laboratories participating in 2 separate College of American Pathologists surveys. The data from those laboratories that analyzed an analyte in both surveys were used to determine for each method the total variance and the within- and between-laboratory components.Setting.—The study included the A mailing of the 2003 College of American Pathologists Ligand Survey and the C mailing of the Chemistry Survey.Main Outcome Measures.—For each analyte, total variance was partitioned into within- and between-laboratory components for each analytic method. The within-laboratory variations were then compared with imprecision criteria based on biological variation.Participants.—The laboratories that reported results on the same analyte using the same method in both surveys.Results.—For each analyte, the median of the long-term within-laboratory variances of each peer group was 78% to 95% of its total-survey variance, and the median long-term within-laboratory coefficients of variation varied from 5.1% to 7.6%. The number of methods that met within-laboratory imprecision goals based on biological criteria were 5 of 5 for cortisol; 5 of 7 for ferritin; 0 of 7 for thyroxine and free thyroxine; and 8 of 8 for thyroid-stimulating hormone.Conclusions.—For all analytes tested, the total within-laboratory component of variance was the major source of variability in this study. In addition, there are several methods, especially for thyroxine and free thyroxine, that may not meet analytic goals in terms of their imprecision.
Collapse
|
70
|
Schreiber WE, Endres DB, McDowell GA, Palomaki GE, Elin RJ, Klee GG, Wang E. Comparison of Fresh Frozen Serum to Proficiency Testing Material in College of American Pathologists Surveys: α-Fetoprotein, Carcinoembryonic Antigen, Human Chorionic Gonadotropin, and Prostate-Specific Antigen. Arch Pathol Lab Med 2005; 129:331-7. [PMID: 15737027 DOI: 10.5858/2005-129-331-coffst] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Context.—Most proficiency testing materials (PTM) contain an artificial matrix that may cause immunoassays to perform differently with this material than with clinical samples. We hypothesized that matrix effects would be reduced by using fresh frozen serum (FFS).
Objective.—To compare the performance of an FFS pool to standard PTM for measurement of α-fetoprotein, carcinoembryonic antigen, human chorionic gonadotropin (hCG), and prostate-specific antigen (PSA).
Design.—One FFS specimen and 4 different admixtures of PTM were distributed in the 2003 College of American Pathologists K/KN-A (for α-fetoprotein, carcinoembryonic antigen, hCG, and total and free PSA) and C-C (hCG only) Surveys.
Participants.—The number of laboratories that participated in the surveys varied from a low of 288 (free PSA, K/KN-A Survey) to a high of 2659 (hCG, C-C Survey).
Main Outcome Measures.—Method imprecision and method bias were compared between the FFS specimen and the standard PTM specimen with the closest value. Method imprecision was determined by calculating the coefficients of variation for each method and for all methods combined. Bias was defined as the proportional difference between peer-group mean and the median of all method means.
Results.—The FFS specimen gave significantly higher imprecision than PTM for the analytes α-fetoprotein, carcinoembryonic antigen, total PSA, and free PSA. For hCG, no substantial imprecision differences were observed in both surveys. Bias was significantly greater for the α-fetoprotein, carcinoembryonic antigen, and total PSA assays and significantly lower for the hCG and free PSA assays when comparing the FFS with the PTM.
Conclusions.—Fresh frozen serum did not provide consistently lower imprecision or bias than standard PTM in a survey of commonly ordered tumor markers.
Collapse
|
71
|
Palmer-Toy DE, Wang E, Winter WE, Soldin SJ, Klee GG, Howanitz JH, Elin RJ. Comparison of Pooled Fresh Frozen Serum to Proficiency Testing Material in College of American Pathologists Surveys: Cortisol and Immunoglobulin E. Arch Pathol Lab Med 2005; 129:305-9. [PMID: 15737022 DOI: 10.5858/2005-129-305-copffs] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Context.—The College of American Pathologists (CAP) provides proficiency testing (PT) surveys to laboratories around the world.
Objectives.—To compare diagnostic assay methods for serum/plasma cortisol and immunoglobulin (Ig) E in terms of their bias and precision, to determine how well CAP PT specimens simulate human serum, and to reassess proficiency test grading criteria in light of these findings.
Design.—A participant-blinded, prospective trial. One vial of pooled fresh frozen serum (FFS) and 4 different admixtures of PT material (PTM) were sent to laboratories participating in PT surveys.
Participants.—Laboratories providing cortisol (>1000) or IgE (>230) results among the subscribers to the CAP surveys, Ligand (General) 2003, set K/KN-A and Chemistry 2003, set C-C.
Main Outcome Measures.—The main outcome measures were (1) bias among laboratories using the same method (peer groups), defined relative to the median of method means (MedMM); (2) imprecision as measured by the SD and coefficient of variation (CV) about each method mean; and (3) total error across laboratories for the FFS cortisol results, defined as |Bias Relative to Reference Method| + 2 SD.
Results.—Cortisol method biases, relative to MedMM, ranged from −22% to 9% for the FFS challenge and from −24% to 36% for comparable PTM challenges. The method biases, relative to the reference method, ranged from −3% to 19% for the FFS challenge. The cortisol method CVs ranged from 4.2% to 13.6% for the FFS challenge and from 4.7% to 12.7% for comparable PTM challenges. Total error across laboratories ranged from 1.4 to 6.9 μg/dL (39 to 190 nmol/L) for the FFS challenge. Immunoglobulin E method biases, relative to MedMM, ranged from −8% to 9% for the FFS challenge and from −7% to 5% for comparable PTM challenges. The IgE method CVs ranged from 3.6% to 6.7% for the FFS challenge and from 3.4% to 9.8% for comparable PTM challenges.
Conclusions.—The bias for cortisol results was less with FFS than with PTM, but imprecision was comparable. The FFS MedMM was 8.5% higher than the reference value. Fresh frozen serum and PTM bias and imprecision for IgE methods were each less than 10%. Because some of the methods demonstrated greater bias when analyzing PTM than FFS, peer group grading of both these analytes is appropriate.
Collapse
|
72
|
Knight GJ, Palomaki GE, Klee GG, Schreiber WE, Cole LA. A Comparison of Human Chorionic Gonadotropin– Related Components in Fresh Frozen Serum With the Proficiency Testing Material Used by the College of American Pathologists. Arch Pathol Lab Med 2005; 129:328-30. [PMID: 15737026 DOI: 10.5858/2005-129-328-acohcg] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractContext.—As part of a College of American Pathologists (CAP) proficiency testing survey, a comparison is made between human chorionic gonadotropin (hCG) results from an actual patient pool and a similarly targeted artificial sample. The goal is to gain insight into the possible source(s) of bias attributable to the proficiency testing material (PTM) with a view toward creating more appropriate survey materials.Objective.—To compare hCG and related variants in a pool of fresh frozen sera (FFS) with that found in PTM.Design.—The 2003 CAP K/KN-A Survey included a FFS specimen along with admixtures of PTM. The FFS (K-02) and 1 PTM admixture (K-01) had similar mean hCG values. Five hCG-related analytes were measured on these 2 samples by a reference laboratory.Participants.—Approximately 1800 clinical laboratories and diagnostic test kit manufacturers participated in the K/ KN-A Survey.Main Outcome Measures.—Method imprecision (coefficient of variation) and method bias (relative difference between peer group mean and all-method median) were computed for the 2 samples. Differences were evaluated with respect to hCG-related analytes levels.Results.—All-method hCG results were 12.9 mIU/mL (12.9 IU/L) for the PTM material and 21.6 mIU/mL (21.6 IU/L) for the FFS material. Method biases for 14 manufacturers were greater for PTM than for FFS (−40% to +35% and −16% to +23%). Twelve of 14 methods had higher coefficients of variation on PTM. Total hCG and free β hCG measurements by the reference laboratory were 14.1 mIU/ mL (14.1 IU/L) for the PTM material and 18.5 mIU/mL (18.5 U/L) for the FFS material (FFS), and 2.4 (PTM) and 0.7 (FFS) mIU/mL (2.4 and 0.7 IU/L), respectively. On a molar basis, free β represented 17% and 4% of the total hCG, respectively. Levels of hyperglycosylated hCG, nicked hCG, and β core fragment were not measurable in either sample.Conclusions.—It is unlikely that the hCG added to the PTM is the source of the increased bias and variability. The main difference is a 3-fold increase in free β found in the PTM, but methods previously found to strongly react with free β were not systematically elevated. The biases between manufacturers found for the FFS specimen are likely attributable to calibration differences.
Collapse
|
73
|
Heufelder AE, Klee GG, Wynne AG, Gharib H. Familial dysalbuminemic hyperthyroxinemia: cumulative experience in 29 consecutive patients. Endocr Pract 2005; 1:4-8. [PMID: 15251607 DOI: 10.4158/ep.1.1.4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE The syndrome of familial dysalbuminemic hyperthyroxinemia (FDH), an inherited abnormality characterized by the presence of a variant serum albumin with preferential affinity for T4, is recognized with increasing frequency as a cause of elevated total and free T4 serum values in clinically euthyroid patients with normal TSH levels. Hyperthyroxinemia caused by this syndrome is occasionally confused with hyperthyroidism or thyroid hormone resistance syndromes, which may prompt unnecessary treatment. To better define the clinical and biochemical characteristics of patients with FDH, we undertook a retrospective analysis of the experience at our institution with this condition. PATIENTS We reviewed our cumulative experience in 29 consecutive patients with FDH diagnosed between 1970 and 1991. RESULTS FDH was diagnosed in 18 males and 11 females (mean age, 42.7 years) on the basis of clinical euthyroidism, increased total T4 and increased/normal free T4 serum values, normal T3 and TSH serum values, increased T4 binding to serum albumin, and low/normal T4 binding to T4-binding globulin and serum prealbumin. Clinical thyroid examination revealed no abnormalities except for goitre in five patients, and the results of radioiodine uptake studies were normal. Patients with subsequently documented FDH were referred for evaluation of "unusual" findings on thyroid function tests or FDH was detected on routine thyroid function tests or identified on family screening. Euthyroid hyperthyroxinemia in combination with a family history compatible with FDH correctly suggested FDH in seven patients. CONCLUSIONS Clinical euthyroidism in conjunction with a normal basal sensitive TSH value in a hyperthyroxinemic patient differentiates euthyroid hyperthyroxinemia from thyrotoxicosis, obviating unnecessary therapy. Detection of excessive thyroxine binding to serum albumin establishes the diagnosis of FDH and allows it to be differentiated from thyroid hormone resistance syndromes. After a diagnosis of FDH has been established, family screening is advisable. Hyperthyroxinemia in clinically euthyroid patients ("euthyroid hyperthyroxinemia") is recognized with increasing frequency and should prompt a careful diagnostic evaluation. The differential diagnosis of this condition may be difficult because it includes various common and unusual syndromes, including quantitative or qualitative changes in thyroid hormone-binding proteins, circulating antibodies against thyroid hormones, resistance to thyroid hormones, influences from drugs, and acute somatic or psychiatric illness (1). The recently recognized syndrome of familial dysalbuminemic hyperthyroxinemia (FDH), an inherited abnormality with autosomal dominant transmission, is characterized by the presence of a variant serum albumin with preferential affinity for T4 (2-4). Typically, FDH is detected incidentally or patients are referred to endocrinologists on the basis of "unusual" results on routine thyroid function testing, revealing consistently elevated total T4 and elevated or normal free T4 values in a clinically euthyroid patient with normal TSH levels (1,5). Unfortunately, hyperthyroxinemia due to FDH may be confused with hyperthyroidism or thyroid hormone resistance syndromes, prompting repeated unnecessary laboratory testing and possibly even inappropriate treatment (1,3,6,7). Herein, we describe the clinical and biochemical characteristics of 29 consecutive patients with documented FDH.
Collapse
|
74
|
Jatoi A, Egner J, Loprinzi CL, Sloan JA, Novotny PJ, Dakhil SR, Mailliard JA, Klee GG, Krook JE. Investigating the utility of serum cytokine measurements in a multi-institutional cancer anorexia/weight loss trial. Support Care Cancer 2005; 12:640-4. [PMID: 15278681 DOI: 10.1007/s00520-004-0624-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND Interleukin-1 beta (IL-1beta), tumor necrosis factor alpha (TNFalpha), and interleukin-6 (IL-6) have been implicated in the cancer anorexia/weight loss syndrome. However, previous smaller studies have yielded conflicting results as to whether circulating, serum concentrations of these cytokines are in fact elevated. As the translational component of a large multi-institutional trial, this study assessed the clinical value of serum concentrations of these cytokines in patients with this syndrome. METHODS Patients with incurable cancer with anorexia and/or weight loss were eligible. All underwent weekly weight measurements and appetite assessment for the first month and then monthly assessments thereafter. Serum was obtained at baseline and at 1 month, and all three cytokines were measured with the Immunolite assay. RESULTS A total of 118 patients participated. At baseline, 99%, 54%, and 47% of patients' samples had undetectable IL-1beta, TNFalpha, and IL-6, respectively. Similar results were obtained at 1 month. No correlations were observed between serum cytokine concentrations and changes in weight or appetite. Baseline serum IL-6 predicted a diminished survival but only after adjustment for age and cancer site. CONCLUSION Serum concentrations of IL-1beta, TNFalpha, and IL-6, as measured in this study, provide data of limited clinical value for patients with the cancer anorexia/weight loss syndrome.
Collapse
|
75
|
Gomez EA, Ehresmann DD, Ledebuhr LK, Eastvold ML, Singh RJ, Klee GG, Grebe SKG. Development and Validation of an Automated Chemiluminometric Immunoassay for Human Intrinsic Factor Antibodies in Serum. Clin Chem 2005; 51:232-5. [PMID: 15613720 DOI: 10.1373/clinchem.2004.043133] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|