51
|
Nicosia A, Iacopino S, Nigro G, Zucchelli G, Tomasi L, D'Agostino C, Ziacchi M, Piacenti M, De Filippo P, Sgarito G, Foti R, Campisi G, Pepi P, Palmisano P. Performance of transcatheter pacing system use in Relation to Patient Age. Eur Heart J 2021. [DOI: 10.1093/eurheartj/ehab724.0408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Real-world safety data on the use of transcatheter pacing systems in particularly young and elderly patients is still limited.
Purpose
The aim of this analysis was to investigate the effect of age on the safety and efficacy of leadless pacemaker implant.
Methods
From May 2016 through July 2019, 577 patients were implanted with a leadless single chamber pacemaker according to current pacing indication in 15 Italian cardiologic centers. The population was divided into age quartiles for evaluation, including: 1) <70 years, 2) 70–77 years, 3) 78–83 years, and 4) ≥83 years. Procedural data, complications, electrical parameters were collected at baseline and during the follow up.
Results
Procedural-related complication occurrence was very low (<1.0%) and similar in the four subgroups according to age. No cardiac tamponade was reported. Among the groups, no difference was observed in procedural time, fluoroscopy time duration and electrical parameters (mean pacing impedance: 750±192 and 599±156, mean pacing threshold: 0.7±0.5 and 0.7±0.6, and mean right ventricular sensing 10.7±6.1 and 11.5±4.8 at implant and last follow up, respectively). Figure 1 showed the distribution of age in the patient population.
Conclusion
The reported data demonstrated a high degree of safety during leadless implant across all patient ages. Procedural complications and device electrical measurements were similar among the different ages.
Funding Acknowledgement
Type of funding sources: None.
Collapse
|
52
|
Russo V, Pafundi PC, Rapacciuolo A, de Divitiis M, Volpicelli M, Ruocco A, Rago A, Uran C, Nappi F, Attena E, Chianese R, Esposito F, Del Giorno G, D'Andrea A, Ducceschi V, Russo G, Ammendola E, Carbone A, Covino G, Manzo G, Montella GM, Nigro G, D'Onofrio A. Cardiac pacing procedures during coronavirus disease 2019 lockdown in Southern Italy: insights from Campania Region. J Cardiovasc Med (Hagerstown) 2021; 22:857-859. [PMID: 33399343 DOI: 10.2459/jcm.0000000000001156] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
53
|
Rapacciuolo A, Iacopino S, D'Onofrio A, Curnis A, Pisanò EC, Biffi M, Della Bella P, Dello Russo A, Caravati F, Zanotto G, Calvi V, Rovaris G, Senatore G, Nicolis D, Santamaria M, Giammaria M, Maglia G, Duca A, Ammirati G, Romano SA, Piacenti M, Celentano E, Bisignani G, Vaccaro P, Miracapillo G, Bertini M, Nigro G, Giacopelli D, Gargaro A, Bisceglia C. Cardiac resynchronization therapy defibrillators in patients with permanent atrial fibrillation. ESC Heart Fail 2021; 8:5204-5212. [PMID: 34514741 PMCID: PMC8712818 DOI: 10.1002/ehf2.13599] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 07/22/2021] [Accepted: 08/19/2021] [Indexed: 11/16/2022] Open
Abstract
Aims There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. Methods and results We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse‐probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow‐up of 24 months, total mortality did not differ between AF and SR groups (propensity‐score‐weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82–2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted‐HR, 1.99 [1.21–3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66–2.53], P = 0.45). During follow‐up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42–256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8–6.7) per 100 patient‐years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9–3.3) per 100 patient‐years. Conclusions Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.
Collapse
|
54
|
Montevecchi G, Masino F, Versari A, Ricci A, Nigro G, Antonelli A. Effect of Kaolin/Defoliation Combined with Dry Ice on Lambrusco Red Wine Production to Constrain the Effects of Climate Change. S AFR J ENOL VITIC 2021. [DOI: 10.21548/42-2-4436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Since viticulture is affected considerably by climate change, it is imperative to encourage research on newstrategies in order to constrain these critical effects on the composition of berries and the quality of wines.A multi-strategy approach composed of (i) kaolin application on foliage, (ii) late tree defoliation and (iii)cryomaceration of grapes with dry ice was evaluated in the production of Lambrusco Salamino wines.Physical, chemical and sensory analyses were carried out on the sample set, including the control wines.In general, cryomaceration with dry ice proved to be a winning choice to lower alcoholic strength (roughly5%). In addition, the wines showed an increase in anthocyanin content by approximately 17%, while thecontent of catechins, flavanols and hydroxycinnamic acids decreased. Consistent with the increase in theanthocyanin content, an increase in colour indices and sensory colour intensity scores was observed. As forthe aromatic profile, 2-phenylethanol showed an increase of approximately 18% in the treated wines while,in parallel, a lower content of C6 alcohols and volatile fatty acids was observed. The multiple adaptationstrategies put in place in the present study show an alternative way to mitigate the severe effects of climatechange on wine production, and to face changing consumer demands.
Collapse
|
55
|
Bianchi V, Bisignani G, Nigro G, Migliore F, Tola G, Viani S, Rossi P, Biffi M, Palmisano P, Checchi L, Licciardello G, Francia P, Leidi C, Lovecchio M, D'Onofrio A. B-AB11-03 OMISSION OF DEFIBRILLATION TESTING DURING S-ICD IMPLANTATION IN CLINICAL PRACTICE: FOLLOW UP ANALYSIS. Heart Rhythm 2021. [DOI: 10.1016/j.hrthm.2021.06.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
56
|
Russo V, Viani S, Migliore F, Nigro G, Biffi M, Tola G, Bisignani G, Dello Russo A, Sartori P, Rordorf R, Ottaviano L, Perego GB, Checchi L, Segreti L, Bertaglia E, Lovecchio M, Valsecchi S, Bongiorni MG. Lead Abandonment and Subcutaneous Implantable Cardioverter-Defibrillator (S-ICD) Implantation in a Cohort of Patients With ICD Lead Malfunction. Front Cardiovasc Med 2021; 8:692943. [PMID: 34395560 PMCID: PMC8356671 DOI: 10.3389/fcvm.2021.692943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 07/06/2021] [Indexed: 11/17/2022] Open
Abstract
Background: When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction. Methods: We analyzed all consecutive patients who underwent S-ICD implantation after abandonment of malfunctioning leads and compared their outcomes with those of patients who underwent extraction and subsequent reimplantation of a single-chamber transvenous ICD (T-ICD). Results: Forty-three patients underwent S-ICD implantation after abandonment of malfunctioning leads, while 62 patients underwent extraction and subsequent reimplantation of a new T-ICD. The two groups were comparable. In the extraction group, no major complications occurred during extraction, while the procedure failed and an S-ICD was implanted in 4 patients. During a median follow-up of 21 months, 3 major complications or deaths occurred in the S-ICD group and 11 in the T-ICD group (HR 1.07; 95% CI 0.29–3.94; P = 0.912). Minor complications were 4 in the S-ICD group and 5 in the T-ICD group (HR 2.13; 95% CI 0.49–9.24; P = 0.238). Conclusions: In the event of ICD lead malfunction, extraction avoids the potential long-term risks of abandoned leads. Nonetheless the strategy of lead abandonment and S-ICD implantation was feasible and safe, with no significant increase in adverse outcomes, and may represent an option in selected clinical settings. Further studies are needed to fully understand the potential risks of lead abandonment. Clinical Trial Registration: URL: ClinicalTrials.gov Identifier: NCT02275637
Collapse
|
57
|
Rago A, Pezzullo E, Malvezzi Caracciolo d'Aquino M, Scognamiglio G, Caso VM, Martone F, Attena E, Parisi V, D'Onofrio A, Golino P, Nigro G, Russo V. Non Vitamin K Antagonist Oral Anticoagulants in Atrial Fibrillation Patients Scheduled for Electrical Cardioversion: A Real-Life Propensity Score Matched Study. J Blood Med 2021; 12:413-420. [PMID: 34113202 PMCID: PMC8187032 DOI: 10.2147/jbm.s299265] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 05/20/2021] [Indexed: 11/23/2022] Open
Abstract
Aim The aim of the present study was to assess the safety and effectiveness of non-vitamin K antagonist oral anticoagulants (NOACs) versus vitamin K antagonists (VKAs) in atrial fibrillation (AF) patients undergoing electrical cardioversion (EC). Methods A propensity score-matched analysis was performed in order to identify two homogeneous groups including AF patients on NOACs and VKAs treatment scheduled for EC. The primary safety endpoint was major bleeding. The composite of stroke, transient ischemic attack (TIA) and systemic embolism (SE) was the primary effectiveness endpoint. The discontinuation rate of anticoagulant therapy was assessed. Results A total of 495 AF patients on NOACs therapy and scheduled for EC were compared to 495 VKAs recipients. No statistically significant differences in the incidence of both major bleeding (1.01% versus 1.4%; P= 0.5) and thromboembolic events (0.6% versus 0.8%; P= 0.7) were observed during a mean follow-up of 15 ± 3 months. The discontinuation rate of NOACs was significantly lower compared to VKAs (1.6% versus 3.6%, P=0.04). Conclusion We showed a safe and effective clinical profile of NOACs among AF patients scheduled for electrical cardioversion in real-life setting. Patients on NOACs therapy showed a lower discontinuation rate compared to those on VKAs.
Collapse
|
58
|
Brignole M, Russo V, Arabia F, Oliveira M, Pedrote A, Aerts A, Rapacciuolo A, Boveda S, Deharo JC, Maglia G, Nigro G, Giacopelli D, Gargaro A, Tomaino M. Cardiac pacing in severe recurrent reflex syncope and tilt-induced asystole. Eur Heart J 2021; 42:508-516. [PMID: 33279955 PMCID: PMC7857694 DOI: 10.1093/eurheartj/ehaa936] [Citation(s) in RCA: 61] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/26/2020] [Accepted: 11/03/2020] [Indexed: 12/16/2022] Open
Abstract
Aim The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial. Methods and results We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS). The primary endpoint was the time to first recurrence of syncope. Patients and independent outcome assessors were blinded to the assigned treatment. After a median follow-up of 11.2 months, syncope occurred in significantly fewer patients in the pacing group than in the control group [10 (16%) vs. 34 (53%); hazard ratio, 0.23; P = 0.00005]. The estimated syncope recurrence rate at 1 year was 19% (pacing) and 53% (control) and at 2 years, 22% (pacing) and 68% (control). A combined endpoint of syncope or presyncope occurred in significantly fewer patients in the pacing group [23 (37%) vs. 40 (63%); hazard ratio, 0.44; P = 0.002]. Minor device-related adverse events were reported in five patients (4%). Conclusion In patients aged 40 years or older, affected by severe recurrent reflex syncope and tilt-induced asystole, dual-chamber pacemaker with CLS is highly effective in reducing the recurrences of syncope. Our findings support the inclusion of tilt testing as a useful method to select candidates for cardiac pacing. Study registration ClinicalTrials.gov identifier NCT02324920, Eudamed number CIV-05-013546.
Collapse
|
59
|
Ducceschi V, Carbone A, Botto G, Nigro G, Lavalle C, Infusino T, Maglia G, Nicolis D, Zingarini G, Del Giorno G, Brasca F, Rago A, Auricchio C, Malacrida M, Sangiuolo R. Optimized radiofrequency lesions through local impedance guidance for effective cavo-tricuspid isthmus ablation in typical right atrial flutter: data from the CHARISMA registry. Europace 2021. [DOI: 10.1093/europace/euab116.059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background
Radiofrequency (RF) catheter ablation of the cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL). However, whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective remains to be established.
Purpose
We aimed to investigate the ability of LI to predict ablation efficacy in patients (pts) with RAFL and to characterize the CTI in terms of LI.
Methods
Consecutive pts undergoing RAFL ablation from the CHARISMA registry were enrolled at 9 centers. A novel RF ablation catheter with dedicated algorithm (DirectSense - DS -) was used to measure LI at the distal electrode of this catheter. RF applications (RFC) were targeted to a minimum LI drop of 10 Ω within 30 seconds and were stopped when a maximum cutoff LI drop of <40 Ω was observed. Successful single RFC was defined according with a split in two separate potentials (SPL), reduction of voltage (RedV) by at least 50% or changes at unipolar EGM (UPC). Agreement among criteria was evaluated. Ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus.
Results
A total of 279 ablation spot lesions were delivered in 30 pts (mean RFC 9 ± 6 lesions per pt): 106 (38%) at anterior, 115 (41%) at mid and 58 (21%) at posterior portions of the CTI. BDB was obtained in all cases and no complications were observed. The median RFC delivery time was 30 [19–45] seconds per lesion. 132 (47%), 150 (54%) and 86 (31%) ablation spots were effective according with SPL, RedV and UPC, respectively. Complete agreement of all the criteria was reached in 70% of the cases. The mean LI was 104.4 ± 11Ω prior to ablation and 92.1 ± 11Ω after ablation (p < 0.0001, mean absolute LI drop 12.2 ± 7Ω, mean time to LI drop 13 ± 8 seconds). Effective ablation spots showed a higher LI drop compared with ineffective sites at each single criteria (16.6 ± 7Ω vs 8.3 ± 4Ω for SPL, p < 0.0001; 16.1 ± 6Ω vs 7.8 ± 5Ω at for RedV, p < 0.0001; 19 ± 6Ω vs 9.2 ± 4Ω for UPC, p < 0.0001) and LI drop values significantly increase according to the number of criteria satisfied (ranging from 7.5Ω % -no criteria- to 19.1 -all criteria-). A 15Ω cut-off value for LI (AUC 0.91, sensitivity = 67%, specificity = 92%, p < 0.0001) was associated with the achievement of all criteria with an OR of 21.9 (95%CI: 11.1 to 43.5, p < 0.0001) and a positive predictive value of 76%. Starting LI and LI drop seem to be higher at mid-septal areas.
Conclusion
In our preliminary experience, a LI-guided approach of CTI seems to be safe and effective in RAFL ablation. The magnitude of LI drop was associated with effective lesion formation and conduction block and could be used as a marker of ablation efficacy.
Collapse
|
60
|
Francia P, Adduci C, Angeletti A, Ottaviano L, Perrotta L, De Vivo S, Bongiorni MG, Migliore F, Russo AD, De Filippo P, Caravati F, Nigro G, Palmisano P, Viani S, D'Onofrio A, Lovecchio M, Valsecchi S, Ziacchi M. Acute shock efficacy of the subcutaneous implantable cardioverter-defibrillator according to the implantation technique. J Cardiovasc Electrophysiol 2021; 32:1695-1703. [PMID: 33969578 DOI: 10.1111/jce.15081] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 04/19/2021] [Accepted: 05/01/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.
Collapse
|
61
|
Palmisano P, Ziacchi M, Ammendola E, D'Onofrio A, Dell'Era G, Laffi M, Biffi M, Nigro G, Bianchi W, Prenna E, Angeletti A, Guido A, Stronati G, Gaggioli G, Dello Russo A, Accogli M, Guerra F. Rate and impact on patient outcome and healthcare utilization of complications requiring surgical revision: Subcutaneous versus transvenous implantable defibrillator therapy. J Cardiovasc Electrophysiol 2021; 32:1712-1723. [PMID: 33969569 DOI: 10.1111/jce.15080] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/21/2021] [Accepted: 05/01/2021] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Comparison data on management of device-related complications and their impact on patient outcome and healthcare utilization between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (TV-ICD) are lacking. We designed this prospective, multicentre, observational registry to compare the rate, nature, and impact of long-term device-related complications requiring surgical revision on patient outcome and healthcare utilization between patients undergoing S-ICD or TV-ICD implantation. METHODS AND RESULTS A total of 1099 consecutive patients who underwent S-ICD or TV-ICD implantation were enrolled. Propensity matching for baseline characteristics yielded 169 matched pairs. Rate, nature, management, and impact on patient outcome of device-related complications were analyzed and compared between two groups. During a mean follow-up of 30 months, device-related complications requiring surgical revision were observed in 20 patients: 3 in S-ICD group (1.8%) and 17 in TV-ICD group (10.1%; p = .002). Compared with TV-ICD patients, S-ICD patients showed a significantly lower risk of lead-related complications (0% vs. 5.9%; p = .002) and a similar risk of pocket-related complications (0.6 vs. 2.4; p = .215) and device infection (0.6% vs. 1.2%; p = 1.000). Complications observed in S-ICD patients resulted in a significantly lower number of complications-related rehospitalizations (median 0 vs. 1; p = .013) and additional hospital treatment days (1.0 ± 1.0 vs. 6.5 ± 4.4 days; p = .048) compared with TV-ICD patients. CONCLUSIONS Compared with TV-ICD, S-ICD is associated with a lower risk of complications, mainly due to a lower risk of lead-related complications. The management of S-ICD complications requires fewer and shorter rehospitalizations.
Collapse
|
62
|
Russo V, Bottino R, D'Andrea A, Silverio A, Di Maio M, Golino P, Nigro G, Valsecchi O, Attena E, Canonico ME, Galasso G, Parodi G, Scudiero F. Chronic Oral Anticoagulation and Clinical Outcome in Hospitalized COVID-19 Patients. Cardiovasc Drugs Ther 2021; 36:705-712. [PMID: 33988835 PMCID: PMC8120255 DOI: 10.1007/s10557-021-07194-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/14/2021] [Indexed: 01/08/2023]
Abstract
PURPOSE The clinical course of COVID-19 may be complicated by acute respiratory distress syndrome (ARDS) and thromboembolic events, which are associated with high risk of mortality. Although previous studies reported a lower rate of death in patients treated with heparin, the potential benefit of chronic oral anticoagulation therapy (OAT) remains unknown. We aimed to investigate the association between OAT with the risk of ARDS and mortality in hospitalized patients with COVID-19. METHODS This is a multicenter retrospective Italian study including consecutive patients hospitalized for COVID-19 from March 1 to April 22, 2020, at six Italian hospitals. Patients were divided into two groups according to the chronic assumption of oral anticoagulants. RESULTS Overall, 427 patients were included; 87 patients (19%) were in the OAT group. Of them, 54 patients (13%) were on treatment with non-vitamin k oral anticoagulants (NOACs) and 33 (8%) with vitamin-K antagonists (VKAs). OAT patients were older and had a higher rate of hypertension, diabetes, and coronary artery disease compared to No-OAT group. The rate of ARDS at admission (26% vs 28%, P=0.834), or developed during the hospitalization (9% vs 10%, P=0.915), was similar between study groups; in-hospital mortality (22% vs 26%, P=0.395) was also comparable. After balancing for potential confounders by using the propensity score matching technique, no differences were found in term of clinical outcome between OAT and No-OAT patients CONCLUSION: Oral anticoagulation therapy, either NOACs or VKAs, did not influence the risk of ARDS or death in patients hospitalized with COVID-19.
Collapse
|
63
|
Russo V, Rapacciuolo A, Pafundi PC, de Divitiis M, Volpicelli M, Ruocco A, Rago A, Uran C, Nappi F, Attena E, Chianese R, Esposito F, Del Giorno G, D’Andrea A, Ducceschi V, Russo G, Ammendola E, Carbone A, Covino G, Manzo G, Montella GM, D’Onofrio A, Nigro G. Cardiac implantable electronic devices replacements in patients followed by remote monitoring during COVID-19 lockdown. EUROPEAN HEART JOURNAL - DIGITAL HEALTH 2021; 2:171-174. [PMID: 37155653 PMCID: PMC7928967 DOI: 10.1093/ehjdh/ztaa018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 12/02/2020] [Accepted: 12/30/2020] [Indexed: 01/25/2023]
Abstract
Aims Following coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess the admission rate for cardiac implantable electronic devices (CIEDs) replacement procedures in Campania, the 3rd-most-populous region of Italy, during COVID-19 lockdown. Methods and results Data were sourced from 16 referral hospitals in Campania from 10 March to 4 May 2020 (lockdown period) and during the same period in 2019. We retrospectively evaluated consecutive patients hospitalized for CIEDs replacement procedures during the two observational periods. The number and type of CIEDs replacement procedures among patients followed by remote monitoring (RM), the admission rate, and the type of hospital admission between the two observational periods were compared. In total, 270 consecutive patients were hospitalized for CIEDs replacement procedures over the two observation periods. Overall CIEDs replacement procedures showed a reduction rate of 41.2% during COVID-19 lockdown. Patients were equally distributed for sex (P = 0.581), and both age [median 76 years (IQR: 68–83) vs. 79 years (IQR: 68–83); P = 0.497]. Cardiac implantable electronic devices replacement procedures in patients followed by RM significantly increased (IR: +211%; P < 0.001), mainly driven by the remarkable increase rate trend of both PM (IR: +475%; P < 0.001) and implantable cardiac defibrillator replacement procedures (IR: +67%, P = 0.01), during COVID-19 lockdown compared with 2019 timeframe. Conclusions We showed a significant increase trend rate of replacement procedures among CIEDs patients followed by RM, suggesting the hypothesis of its increased use to closely monitoring and to optimize the hospital admission time during COVID-19 lockdown.
Collapse
|
64
|
Paoli D, Pallotti F, Nigro G, Aureli A, Perlorca A, Mazzuti L, Di Carlo D, Turriziani O, Lenzi A, Lombardo F. Sperm cryopreservation during the SARS-CoV-2 pandemic. J Endocrinol Invest 2021; 44:1091-1096. [PMID: 33040303 PMCID: PMC7547554 DOI: 10.1007/s40618-020-01438-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 09/26/2020] [Indexed: 12/12/2022]
Abstract
PURPOSE Sperm cryopreservation is fundamental in the management of patients undergoing gonadotoxic treatments. Concerns have risen in relation to SARS-CoV-2 and its potential for testicular involvement, since SARS-CoV-2-positive cryopreserved samples may have unknown effects on fertilization and embryo safety. This study therefore aimed to analyze the safety of sperm cryopreservation for cancer patients after the onset of the pandemic in Italy, through assessment of the risk of SARS-CoV-2 exposure and viral RNA testing of semen samples. METHODS We recruited 10 cancer patients (mean age 30.5 ± 9.6 years) referred to our Sperm Bank during the Italian lockdown (from March 11th to May 4th 2020) who had not undergone a nasopharyngeal swab for SARS-CoV-2 testing. Patients were administered a questionnaire on their exposure to COVID-19, and semen samples were taken. Before cryopreservation, SARS-CoV-2 RNA was extracted from a 150 µl aliquot of seminal fluid in toto using QIAamp viral RNA kit (Qiagen) and amplified by a real time RT PCR system (RealStar SARS-CoV2 RT PCR, Altona Diagnostics) targeting the E and S genes. RESULTS The questionnaire and medical interview revealed that all patients were asymptomatic and had had no previous contact with COVID-19 infected patients. All semen samples were negative for SARS-CoV-2 RNA. CONCLUSION This preliminary assessment suggests that a thorough evaluation (especially in the setting of a multidisciplinary team) and molecular confirmation of the absence of SARS-CoV-2 in seminal fluid from asymptomatic cancer patients may assist in ensuring the safety of sperm cryopreservation.
Collapse
|
65
|
Russo V, Pafundi PC, Caturano A, Dendramis G, Ghidini AO, Santobuono VE, Sciarra L, Notarstefano P, Rucco MA, Attena E, Floris R, Romeo E, Sarubbi B, Nigro G, D'Onofrio A, Calò L, Nesti M. Electrophysiological Study Prognostic Value and Long-Term Outcome in Drug-Induced Type 1 Brugada Syndrome: The IBRYD Study. JACC Clin Electrophysiol 2021; 7:1264-1273. [PMID: 33933405 DOI: 10.1016/j.jacep.2021.03.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 03/11/2021] [Accepted: 03/14/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVES This study aimed to retrospectively assess long-term outcome and the prognostic role of electrophysiological study (EPS) for risk stratification of drug-induced type 1 Brugada syndrome (BrS) patients. BACKGROUND BrS is a hereditary cardiac disease, predisposing to sudden cardiac death. Few real-world data are available on long-term outcomes of drug-induced type 1 BrS patients, and questions about risk stratification still remain unanswered. METHODS The IBRYD (Italian Brugada Syndrome) study is a multicenter observational retrospective study. A total of 226 drug-induced type 1 BrS patients were enrolled from 9 Italian tertiary referral institutions. Primary endpoint was a composite of appropriate implantable cardioverter-defibrillator (ICD) therapy and sudden cardiac death. The authors further assessed clinical predictors to ICD implantation, as well as for arrhythmia induction at EPS, along with EPS as potential risk factor for the outcomes of interest. RESULTS 142 patients (62.8%) received an ICD due to syncope and/or inducible ventricular tachyarrhythmias at EPS. During a median follow-up of 106 months, 11 patients (4.9%) experienced primary outcome events. The ICD therapy median annual incidence over 8 years was 0.38% (interquartile range: 0% to 1.47%). Ventricular tachyarrhythmia inducibility during EPS was not predictive of arrhythmic events in ICD recipients versus non-ICD patients and in symptomatic versus asymptomatic subgroups, showing a low positive predictive value (9.6% and 8.9%, respectively) versus a high negative predictive value (96.6% and 95%, respectively). The authors reported 29 ICD-related complications and 4.9% inappropriate shocks. CONCLUSIONS Drug-induced type 1 BrS patients have a very low arrhythmic risk. Clinical decision for implantation is supported by syncope and/or EPS positivity, though they fail to stratify high-risk patients. A better risk-to-benefit ratio should be pursued, considering both arrhythmic risk and ICD-related complications.
Collapse
|
66
|
Ramadan MS, Russo V, Nigro G, Durante-Mangoni E, Zampino R. Interplay between Heart Disease and Metabolic Steatosis: A Contemporary Perspective. J Clin Med 2021; 10:jcm10081569. [PMID: 33917867 PMCID: PMC8068259 DOI: 10.3390/jcm10081569] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 03/26/2021] [Accepted: 04/03/2021] [Indexed: 12/12/2022] Open
Abstract
The liver-heart axis is a growing field of interest owing to rising evidence of complex bidirectional interplay between the two organs. Recent data suggest non-alcoholic fatty liver disease (NAFLD) has a significant, independent association with a wide spectrum of structural and functional cardiac diseases, and seems to worsen cardiovascular disease (CVD) prognosis. Conversely, the effect of cardiac disease on NAFLD is not well studied and data are mostly limited to cardiogenic liver disease. We believe it is important to further investigate the heart-liver relationship because of the tremendous global health and economic burden the two diseases pose, and the impact of such investigations on clinical decision making and management guidelines for both diseases. In this review, we summarize the current knowledge on NAFLD diagnosis, its systemic manifestations, and associations with CVD. More specifically, we review the pathophysiological mechanisms that govern the interplay between NAFLD and CVD and evaluate the relationship between different CVD treatments and NAFLD progression.
Collapse
|
67
|
Renon F, Rago A, Liccardo B, D'Andrea A, Riegler L, Golino P, Nigro G, Russo V. Direct Oral Anticoagulants Plasma Levels Measurement: Clinical Usefulness from Trials and Real-World Data. Semin Thromb Hemost 2021; 47:150-160. [PMID: 33636746 DOI: 10.1055/s-0041-1723770] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Measurement of direct oral anticoagulants (DOACs) activity is not routinely necessary. Indeed, evaluation of DOACs plasmatic concentration is discouraged for the majority of patients, due to the lack of outcome data supporting this approach. Nevertheless, DOAC measurements may be useful in emergency situations such as serious bleeding events, need for urgent invasive procedures, and acute ischemic stroke or in managing anticoagulation in "special populations" not adequately studied in clinical trials, for example the very elderly or those at the extremes of body weight. The aim of this review is to describe and summarize the methods for DOACs activity evaluation and the settings in which their plasma level measurement may be indicated, analyzing indications from scientific societies and evidence from clinical trials, as well as real world data on the usefulness of DOACs plasma levels "monitoring."
Collapse
|
68
|
Russo V, Cassini R, Caso V, Donno C, Laezza A, Naddei M, Fiorelli A, Golino P, Nigro G. Nursing Teleconsultation for the Outpatient Management of Patients with Cardiovascular Disease during COVID-19 Pandemic. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18042087. [PMID: 33669951 PMCID: PMC7924875 DOI: 10.3390/ijerph18042087] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 02/15/2021] [Accepted: 02/16/2021] [Indexed: 02/06/2023]
Abstract
Introduction: During the COVID-19 outbreak, non-urgent clinic visits or cardiac interventional procedures were postponed to a later date, and the implementation of telemedicine has guaranteed continuity of care for patients with chronic diseases. The aim of our study was to describe the medical interventions following nursing teleconsultation for the outpatient management of patients with cardiovascular diseases during the COVID-19 pandemic. Materials and Methods: All patients who did not attend the follow-up visit from 4 to 15 April 2020 at our institution and who were re-scheduled due to the COVID-19 lockdown were selected to be enrolled in the study. Each patient was followed by a semi-structured telephonic interview performed by a nurse. The outcomes of our study were to assess the patients' adherence to nursing teleconsultation and the usefulness of nursing teleconsultation to detect clinical conditions in need of medical intervention. Results: In total, 203 patients (81%) underwent nursing teleconsultation in a mean time of 7 ± 3 days from the outpatient visit lost due to the COVID-19 lockdown. Furthermore, 53 patients (26%) showed poor adherence to nursing teleconsultation. Among the 150 patients (mean age 67 ± 10 years; 68% male) who completed the telephonic interview, the nursing teleconsultation revealed the need of medical intervention in 69 patients (46%), who were more likely at very high cardiovascular risk (77% vs. 48%; p < 0.0003) and who showed a higher prevalence of dyslipidemia (97% vs. 64%; p < 0.0001) and coronary artery disease (75% vs. 48%, p < 0.0008) compared to those not in need of any intervention. The up-titration of the lipid-lowering drugs (n: 32, 74%) was the most frequent medical intervention following the nursing teleconsultation. The mean time between the nursing teleconsultation and the date of the rescheduled in-person follow-up visit was 164 ± 36 days. Conclusions: Nursing teleconsultation is a simple and well-tolerated strategy that ensures the continuity of care and outpatient management for patients with cardiovascular diseases during the COVID-19 pandemic.
Collapse
|
69
|
Romeo E, D'Alto M, Cappelli M, Nigro G, Correra A, Colonna D, Sarubbi B, Golino P. Retrieval of a leadless transcatheter pacemaker from the right pulmonary artery: A case report. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:952-954. [PMID: 33283282 DOI: 10.1111/pace.14135] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 11/03/2020] [Accepted: 11/29/2020] [Indexed: 11/29/2022]
Abstract
This case report describes a procedure of retrieval of a leadless transcatheter pacemaker from the right pulmonary artery 3 days after device implantation. An 80-year-old man affected by ischemic cardiomyopathy and sinus node dysfunction was implanted with a leadless transcatheter pacemaker in the low septum of the right ventricle. Three days after the procedure, the leadless pacemaker migrated into a side branch of the right pulmonary artery. The device was successfully removed using two snares hooked to a tine via the proximal retrieval feature.
Collapse
|
70
|
Russo V, Papa AA, Lioncino M, Rago A, Di Fraia F, Palladino A, Politano L, Golino P, Nigro G. Prevalence of atrial fibrillation in myotonic dystrophy type 1: A systematic review. Neuromuscul Disord 2021; 31:281-290. [PMID: 33573883 DOI: 10.1016/j.nmd.2021.01.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 12/22/2020] [Accepted: 01/02/2021] [Indexed: 12/26/2022]
Abstract
Cardiac involvement is recorded in about 80% of patients affected by myotonic dystrophy type 1 (DM1). The prevalence of cardiac conduction abnormalities is well described. Data regarding the prevalence of atrial fibrillation (AF) are still conflicting. The primary objective of this review was to assess the prevalence of AF in DM1. The secondary aim was to examine the association of clinical features with AF, to detect predisposing and/or influencing prognosis factors. A systematic search was developed in MEDLINE, EMBASE, Cochrane Register of Controlled Trials and Web of Science databases, to identify original reports between January 1, 2002 and January 30, 2020, assessing the prevalence of AF in DM1 population. Retrospective/prospective cohort studies and case series describing the prevalence of atrial fibrillation evaluated by periodic electrocardiogram (ECG) and/or ECG Holter 24 h, external loop recording (ELR) and implantable devices interrogation in DM1 patients were included. Case reports, simple reviews, commentaries and editorials were excluded. Thirteen reports fulfilled eligibility criteria and were included in our systematic review. According to the results from all the evaluated studies, the mean prevalence of AF in DM1 patients was 10.9% (n = 404) in 3677 DM1 patients. Male sex, conduction defects, echocardiographic findings of prolonged atrial electromechanical delay seem to be strongly associated with atrial fibrillation, representing factors favoring its onset. DM1 patients who develop AF seem to have a higher risk of cardiovascular and non-cardiovascular death. Further studies are needed to assess the prevalence of AF in DM1 patients and to investigate ECG abnormalities and other clinical features associated with this condition.
Collapse
|
71
|
Biffi M, Bongiorni MG, D'Onofrio A, Manzo M, Pieragnoli P, Palmisano P, Ottaviano L, Perego GB, Pangallo A, Lavalle C, Bonfantino V, Nigro G, Landolina ME, Katsouras G, Diemberger I, Viani S, Bianchi V, Lovecchio M, Valsecchi S, Ziacchi M. Is 40 Joules Enough to Successfully Defibrillate With Subcutaneous Implantable Cardioverter-Defibrillators? JACC Clin Electrophysiol 2021; 7:767-776. [PMID: 33516714 DOI: 10.1016/j.jacep.2020.11.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 11/02/2020] [Accepted: 11/04/2020] [Indexed: 01/17/2023]
Abstract
OBJECTIVES This study evaluated the efficacy of conversion test performed at 40 J (defibrillation margin ≥40 J), and factors potentially associated with test failure were identified. BACKGROUND Current subcutaneous implantable cardioverter-defibrillator (S-ICD) devices deliver a maximum of 80 J. Functional defibrillation testing is recommended at S-ICD implantation, and it is usually conducted by delivering a shock energy of 65 J to ensure a safety defibrillation margin ≥15 J. Although high rates of successful conversion were reported at 65 J, limited data exist on the defibrillation margin extent. METHODS Ventricular fibrillation was induced and conversion test was performed by delivering a 40-J shock in 308 patients. Success was defined as termination of ventricular fibrillation by the first shock delivered in standard polarity. The S-ICD system positioning was evaluated with the PRAETORIAN score using bidirectional chest X-rays. RESULTS The generator was positioned in an intermuscular pocket in 301 patients (98%) and the lead was implanted by means of a 2-incision technique. The PRAETORIAN score was <90 (low risk of conversion failure) in 293 (95%) patients. Overall, ventricular fibrillation termination occurred in 259 (84%) patients with 40 J. Male gender (odds ratio [OR]: 3.79; 95% confidence interval [CI]: 1.09 to 13.14; p = 0.036), body mass index (OR: 1.09; 95% CI: 1.01 to 1.19; p = 0.036), dilated cardiomyopathy with reduced ejection fraction (OR: 0.42; 95% CI: 0.20 to 0.87; p = 0.019), and PRAETORIAN score >50 (OR: 2.93; 95% CI: 1.26 to 6.83; p = 0.013) were independently associated with conversion failure. CONCLUSIONS The authors showed a high rate of defibrillation success with 40-J shocks in S-ICD systems implanted by means of modern surgical techniques. The variables associated with shock failure were male gender, higher body mass index, and suboptimal device position according to the PRAETORIAN score.
Collapse
|
72
|
Palmisano P, Dell'Era G, Pellegrino PL, Ammendola E, Ziacchi M, Guerra F, Aspromonte V, Laffi M, Pimpini L, Santoro F, Boggio E, Guido A, Patti G, Brunetti ND, Nigro G, Biffi M, Russo AD, Gaggioli G, Accogli M. Causes of syncopal recurrences in patients treated with permanent pacing for bradyarrhythmic syncope: Findings from the SYNCOPACED registry. Heart Rhythm 2021; 18:770-777. [PMID: 33465512 DOI: 10.1016/j.hrthm.2021.01.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/06/2021] [Accepted: 01/07/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Few studies have examined the causes of syncope/collapse recurrences in patients with a previously implanted pacemaker for bradyarrhythmic syncope. OBJECTIVE The purpose of this study was to assess the causes of syncope/collapse recurrences after pacemaker implantation for bradyarrhythmic syncope in a large patient population. METHODS The SYNCOpal recurrences in patients treated with permanent PACing for bradyarrhythmic syncope (SYNCOPACED) registry was a prospective multicenter observational registry enrolling 1364 consecutive patients undergoing pacemaker implantation for bradyarrhythmic syncope. During follow-up, the time to the first syncope/collapse recurrence was recorded. Patients with syncope/collapse recurrences underwent a predefined diagnostic workup aimed at establishing the mechanism of syncope/collapse. RESULTS During a median follow-up of 50 months, 213 patients (15.6%) reported at least 1 syncope/collapse recurrence. The risk of syncope/collapse recurrence was highest in patients who underwent implantation for cardioinhibitory vasovagal syncope (26.4%), followed by unexplained syncope and chronic bifascicular block (21.5%), cardioinhibitory carotid sinus syndrome (17.2%), atrial fibrillation needing pacing (15.5%), atrioventricular block (13.6%), and sinus node disease (12.5%) (P = .017). The most frequent cause of syncope/collapse recurrence was reflex syncope (27.7%), followed by orthostatic hypotension (26.3%), pacemaker or lead malfunction (5.6%), structural cardiac disease (5.2%), and atrial and ventricular tachyarrhythmias (4.7% and 3.8%, respectively). In 26.8% of cases, the mechanism of syncope/collapse remained unexplained. CONCLUSION In patients receiving a pacemaker for bradyarrhythmic syncope, reflex syncope and orthostatic hypotension are the most frequent mechanisms of syncope/collapse recurrence after implantation. Pacing system malfunction, structural cardiac diseases, and tachyarrhythmias are rare mechanisms. The mechanism remains unexplained in >25% of patients.
Collapse
|
73
|
Russo V, Di Maio M, Mottola FF, Pagnano G, Attena E, Verde N, Di Micco P, Silverio A, Scudiero F, Nunziata L, Fele N, D'Andrea A, Parodi G, Albani S, Scacciatella P, Nigro G, Severino S. Clinical characteristics and prognosis of hospitalized COVID-19 patients with incident sustained tachyarrhythmias: A multicenter observational study. Eur J Clin Invest 2020; 50:e13387. [PMID: 32813877 PMCID: PMC7460920 DOI: 10.1111/eci.13387] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 08/03/2020] [Accepted: 08/17/2020] [Indexed: 12/15/2022]
Abstract
INTRODUCTION Little is still known about the prognostic impact of incident arrhythmias in hospitalized patients with COVID-19. The aim of this study was to evaluate the incidence and predictors of sustained tachyarrhythmias in hospitalized patients with COVID-19, and their potential association with disease severity and in-hospital mortality. MATERIALS AND METHODS This was a retrospective multicenter observation study including consecutive patients with laboratory confirmed COVID-19 admitted to emergency department of ten Italian Hospitals from 15 February to 15 March 2020. The prevalence and the type of incident sustained arrhythmias have been collected. The correlation between the most prevalent arrhythmias and both baseline characteristics and the development of ARDS and in-hospital mortality has been evaluated. RESULTS 414 hospitalized patients with COVID-19 (66.9 ± 15.0 years, 61.1% male) were included in the present study. During a median follow-up of 28 days (IQR: 12-45), the most frequent incident sustained arrhythmia was AF (N: 71; 17.1%), of which 50 (12.1%) were new-onset and 21 (5.1%) were recurrent, followed by VT (N: 14, 3.4%) and supraventricular arrhythmias (N: 5, 1.2%). Incident AF, both new-onset and recurrent, did not affect the risk of severe adverse events including ARDS and death during hospitalization; in contrast, incident VT significantly increased the risk of in-hospital mortality (RR: 2.55; P: .003). CONCLUSIONS AF is the more frequent incident tachyarrhythmia; however, it not seems associated to ARDS development and death. On the other hand, incident VT is a not frequent but independent predictor of in-hospital mortality among hospitalized COVID-19 patients.
Collapse
|
74
|
Bottino R, Carbone A, Liccardo B, D'Andrea A, Rago A, Papa AA, Spaccarotella C, Golino P, Nigro G, Russo V. Edoxaban (LIXIANA ®) in the treatment of venous thromboembolism. Future Cardiol 2020; 17:779-791. [PMID: 33231106 DOI: 10.2217/fca-2020-0139] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Standard therapy for venous thromboembolism (VTE) includes the use of heparins and vitamin K antagonists. Randomized clinical trials have shown that non-vitamin K oral anticoagulants are as effective and safe as standard therapy in VTE treatment, with an improved pharmacological profile. Edoxaban, a direct inhibitor of factor Xa, has demonstrated noninferiority to standard therapy for the treatment of VTE, preserving a high safety profile even in long-term therapy, in frail patients and in severe clinical presentations. The present paper focuses on the role of edoxaban in VTE treatment, from general population to cancer patients, presenting the available data from randomized clinical trials and real world, to discuss edoxaban use in clinical practice.
Collapse
|
75
|
Russo V, Pafundi PC, Rapacciuolo A, D'Andrea A, de Devitiis M, Volpicelli M, Ruocco A, Nigro G, D'Onofrio A. Arrhythmogenic syncope leading to cardiac rhythm management procedures during COVID-19 lockdown. Expert Rev Med Devices 2020; 17:1207-1210. [PMID: 33090884 DOI: 10.1080/17434440.2020.1841632] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Introduction: Following the coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess admission rate for syncope leading to cardiac rhythm management (CRM) procedures in Campania, the third-most-populous region of Italy, during COVID-19 lockdown. Methods: Data were sourced from 14 referral hospitals in Campania from 10th March to 4 May 2020 (lockdown period) and during the same period in 2019. Among consecutive patients hospitalized for CRM procedures during the two observational periods, we retrospectively evaluated those admitted for arrhythmogenic syncope. Admission rate and the type of hospital admission between the two observational periods were compared. Results: Among 951 consecutive patients hospitalized for CRM procedures, 204 were admitted for arrhythmogenic syncope leading to CRM procedures. A significant increase in admission was shown in 2020 compared to 2019 (26.4% vs. 18.3%; P = 0.003). Moreover, regarding the type of admission to hospitals, attendance at the emergency department (ED) significantly increased (83.5% vs. 56.1%; P < 0.001); conversely, a significant decrease in urgent unplanned hospitalizations (6.2% vs. 35.5%; P < 0.001) was observed during COVID-19 lockdown. Conclusions: The hospitalization for arrhythmogenic syncope leading to CRM procedures increased during COVID-19 lockdown.
Collapse
|