101
|
Vazquez de Prada JA, Jiang L, Handschumacher MD, Xie SW, Rivera JM, Schwammenthal E, Guerrero JL, Weyman AE, Levine RA, Picard MH. Quantification of pericardial effusions by three-dimensional echocardiography. J Am Coll Cardiol 1994; 24:254-9. [PMID: 8006275 DOI: 10.1016/0735-1097(94)90571-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVES The purpose of this study was to examine the accuracy of three-dimensional echocardiography for the quantification of asymmetric pericardial effusion volume and to compare this new technique with two-dimensional echocardiography. BACKGROUND Quantification of pericardial effusion by two-dimensional echocardiography relies on a symmetric distribution of the fluid. Three-dimensional echocardiography can quantitate volume without these limitations, but its accuracy for pericardial effusion volume has not yet been assessed. METHODS In six open chest dogs, 41 different asymmetrically distributed pericardial effusions of known volume were created by serial infusions of fluid through a pericardial catheter. The hearts were imaged using an automated echocardiographic method that integrates three-dimensional spatial and imaging data. The surfaces of the pericardial sac and heart were then reconstructed, and the volumes of pericardial effusions were calculated. Two-dimensional echocardiography was performed simultaneously, and volumes were calculated using the prolate ellipsoid method. Asymmetric distribution of the fluid was obtained by applying localized hydrostatic pressure to the pericardium. RESULTS The volumes of pericardial effusion quantified using three-dimensional echocardiography correlated well with actual volumes (y = 1.0x - 1.4, SEE = 7.7 ml, r = 0.98). Two-dimensional echocardiography had an acceptable correlation (y = 1.0x + 2.3, SEE = 23 ml, r = 0.84), but a marked degree of variation from the true value was observed for any individual measurement. CONCLUSIONS Three-dimensional echocardiography accurately quantifies pericardial effusion volume in vivo, even when the fluid is distributed asymmetrically, whereas two-dimensional echocardiography is less reliable. This new technique may be of clinical value in quantitating pericardial effusion, especially in the serial evaluation of asymmetric or loculated effusions.
Collapse
|
102
|
Collen D, Stassen JM, Yasuda T, Refino C, Paoni N, Keyt B, Roskams T, Guerrero JL, Lijnen HR, Gold HK. Comparative thrombolytic properties of tissue-type plasminogen activator and of a plasminogen activator inhibitor-1-resistant glycosylation variant, in a combined arterial and venous thrombosis model in the dog. Thromb Haemost 1994; 72:98-104. [PMID: 7974384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
rt-PA-K, a variant of recombinant tissue-type plasminogen activator (rt-PA) with substitution of amino acids 296 to 299 with alanine (KHRR296-299AAAA) has increased fibrin-specificity and reduced sensitivity to plasminogen activator inhibitor-1; rt-PA-T, with threonine 103 replaced by asparagine has an additional glycosylation site and a reduced clearance; and rt-PA-N, with asparagine 117 mutagenized to glutamine lacks the high mannose carbohydrate side chain. We have investigated whether combination of these properties in a single molecule might yield an improved thrombolytic agent. The thrombolytic potency and fibrin-specificity of the combination mutant rt-PA-TNK was compared with that of rt-PA in a combined venous whole blood clot model and platelet-rich arterial eversion graft thrombosis model in dogs given intravenous heparin and aspirin. Infusion of 0.125 to 1.0 mg/kg over 60 min in groups of 4 to 5 dogs produced dose-dependent fibrin-specific venous clot lysis. The thrombolytic potency (percent lysis per mg compound administered per kg body weight) of rt-PA-TNK was significantly higher than that of rt-PA as evidenced by a higher maximal rate of lysis of 480 +/- 100% versus 140 +/- 40% within the 2 h observation period per mg of compound administered per kg body weight (mean +/- SEM, p = 0.004) and a significantly lower dose of 0.08 +/- 0.01 versus 0.21 +/- 0.04 mg/kg body weight at which the maximal rate of lysis was obtained (p = 0.004).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
103
|
Davidoff R, Picard MH, Force T, Thomas JD, Guerrero JL, McGlew S, Weyman AE. Spatial and temporal variability in the pattern of recovery of ventricular geometry and function after acute occlusion and reperfusion. Am Heart J 1994; 127:1231-41. [PMID: 8172051 DOI: 10.1016/0002-8703(94)90041-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Myocardial ischemia and infarction are known to cause changes in both ventricular shape and function. Little is known about the recovery of ventricular geometry after transient myocardial ischemia and its relationship to recovery of function. To examine the pattern of recovery of ventricular geometry following transient coronary artery occlusion and to assess the relationship of this to the return of systolic function, we used echocardiography to study 13 dogs following 15-minute occlusion of the left anterior descending coronary artery. During ischemia, total endocardial surface area (ESA) increased from 32.55 +/- 1.77 to 45.36 +/- 3.18 cm2 (p = 0.001). The most striking increase was at the apex, where circumference increased from 5.04 +/- 0.24 at baseline to 7.86 +/- 0.43 cm at the end of occlusion (p = 0.0001), an increase of 58%. During reperfusion, ventricular geometry rapidly returned toward normal (baseline), with recovery of 80% of the increase in ESA evident by 15 minutes of reperfusion. Recovery of systolic function was substantially slower (p < 0.005 for all periods of observation during the 2 hours of reperfusion). During reperfusion, recovery of ventricular geometry and function was not uniform throughout the ischemic bed. The apex recovered most slowly, with the centroid of the area of abnormal contraction progressively moving along the long axis of the left ventricle toward the apex. There was also a progressive decrease in the radius of the area of dysfunction, from 2.0 +/- 0.15 at end occlusion to 0.13 +/- 0.07 cm at 120 minutes of reperfusion (p = 0.0001). There was no difference in blood flow between the apical and anterior segments during ischemia or reperfusion. Reperfusion favorably reduced the ischemic zone dilation before recovery of active systolic function and geometric recovery thus may be important in determining ultimate functional recovery. In addition, recovery of function proceeded inward towards the center of the ischemic territory and in a wavefront from the base to apex. This heterogeneous and asymmetric recovery suggests that sampling at one point within the ischemic zone may not reflect the true temporal pattern of recovery.
Collapse
|
104
|
Morrissey RL, Siu SC, Guerrero JL, Newell JB, Weyman AE, Picard MH. Automated assessment of ventricular volume and function by echocardiography: validation of automated border detection. J Am Soc Echocardiogr 1994; 7:107-15. [PMID: 8185955 DOI: 10.1016/s0894-7317(14)80116-8] [Citation(s) in RCA: 57] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
To determine the utility of a new on-line echocardiographic automated border detection (ABD) algorithm in assessing ventricular volume and ejection fraction, an optimal model was studied. This open-chest canine model allowed continuous measurement of actual left ventricular volume. In four dogs, true end-systolic and end-diastolic volume and ejection fraction were compared with those obtained by two-dimensional echocardiography with an automated method calculated from a border detection algorithm to define left ventricular endocardium and the single-plane Simpson method to calculate volume. Left ventricular volumes that used manual, off-line tracings of the left ventricle by two-dimensional echocardiograms and the single-plane Simpson method were compared. The automated echocardiographic volumes correlated with true volumes (y = 0.7x + 8.9; standard error of the estimate = 13.5 cc; r = 0.81). A significant mean underestimation of 11 +/- 15 cc was noted (p < 0.0001). Volumes obtained from the manual tracings of left ventricular endocardial contours also correlated well with true volumes (y = 0.89x + 4; standard error of the estimate = 6.7 cc; r = 0.96). However, the 3 +/- 7 underestimation was significantly lower than the error of the ABD method (p = 0.00005). Both on-line ABD and off-line ejection fractions correlated well with true ejection fractions (r = 0.94 and 0.96, respectively). There was no statistically significant difference between the mean errors of the ABD or manually derived ejection fractions. In the setting of optimal left ventricular imaging, the on-line and rapid features of this automated method make it potentially useful for quickly obtaining left ventricular volumes and ejection fraction.
Collapse
|
105
|
Rivera JM, Siu SC, Handschumacher MD, Lethor JP, Guerrero JL, Vlahakes GJ, Mitchell JD, Weyman AE, King ME, Levine RA. Three-dimensional reconstruction of ventricular septal defects: validation studies and in vivo feasibility. J Am Coll Cardiol 1994; 23:201-8. [PMID: 8277082 DOI: 10.1016/0735-1097(94)90521-5] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVES The purpose of this study was to demonstrate the feasibility of in vivo three-dimensional reconstruction of ventricular septal defects and to validate its quantitative accuracy for defect localization in excised hearts (used to permit comparison of three-dimensional and direct measurements without cardiac contraction). BACKGROUND Appreciating the three-dimensional spatial relations of ventricular septal defects could be useful in planning surgical and catheter approaches. Currently, however, echocardiography provides only two-dimensional views, requiring mental integration. A recently developed system automatically combines two-dimensional echocardiographic images with their spatial locations to produce a three-dimensional construct. METHODS Surgically created ventricular septal defects of varying size and location were imaged and reconstructed, along with the left and right ventricles, in the beating heart of six dogs to demonstrate the in vivo feasibility of producing a coherent image of the defect that portrays its relation to surrounding structures. Two additional gel-filled excised hearts with defects were completely reconstructed. Quantitative localization of the defects relative to other structures (ventricular apexes and valve insertions) was then validated for seven defects in excised hearts. The right septal margins of the exposed defects were also traced and compared with their reconstructed areas and circumferences. RESULTS The three-dimensional images provided coherent images and correct spatial appreciation of the defects (two inlet, two trabecular, one outlet and one membranous Gerbode in vivo; one inlet and one apical in excised hearts). The distances between defects and other structures in the excised hearts agreed well with direct measures (y = 1.05x-0.18, r = 0.98, SEE = 0.30 cm), as did reconstructed areas (y = 1.0x-0.23, r = 0.98, SEE = 0.21 cm2) and circumferences (y = 0.97x + 0.13, r = 0.97, SEE = 0.3 cm). CONCLUSIONS Three-dimensional reconstruction of ventricular septal defects can be achieved in the beating heart and provides an accurate appreciation of defect size and location that could be of value in planning interventions.
Collapse
|
106
|
Kohmura C, Gold HK, Yasuda T, Holt R, Nedelman MA, Guerrero JL, Weisman HF, Collen D. A chimeric murine/human antibody Fab fragment directed against the platelet GPIIb/IIIa receptor enhances and sustains arterial thrombolysis with recombinant tissue-type plasminogen activator in baboons. ARTERIOSCLEROSIS AND THROMBOSIS : A JOURNAL OF VASCULAR BIOLOGY 1993; 13:1837-42. [PMID: 8241105 DOI: 10.1161/01.atv.13.12.1837] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Inhibition of the platelet glycoprotein (GP) IIb/IIIa receptor with the murine monoclonal antibody 7E3 abolishes ex vivo platelet aggregation, reduces thrombogenicity, and sustains arterial recanalization with recombinant tissue-type plasminogen activator (rt-PA). A chimeric murine/human Fab fragment of 7E3 (c7E3-Fab) has a markedly reduced immunogenicity, but its potency as an adjunct for thrombolysis with rt-PA has not been evaluated. The effects of a single intravenous bolus injection of aspirin (17 mg/kg) or c7E3-Fab (0.45 mg/kg) on thrombolysis and reocclusion induced with rt-PA were studied in groups of six baboons with femoral arterial thrombosis and superimposed high-grade stenosis. This dose of c7E3-Fab blocked 96 +/- 1% of the platelet GPIIb/IIIa receptors and abolished ADP-induced platelet aggregation. Bolus intravenous injections of rt-PA (0.25 mg/kg) were repeated at 15-minute intervals until reperfusion occurred (maximum of four injections). In the aspirin group, reperfusion was obtained within 51 +/- 16 minutes (mean +/- SD) but was rapidly followed by reocclusion within 6 +/- 9 minutes and by cyclic reflow and reocclusion. In the c7E3-Fab group, reperfusion was obtained within 25 +/- 8 minutes (P < .01 versus aspirin group) and was associated with a delayed reocclusion of 63 +/- 63 minutes (P < .05 versus aspirin group). Template bleeding times remained unchanged in the aspirin/rt-PA group but were markedly prolonged (to > 30 minutes) in the c7E3-Fab/rt-PA group.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
107
|
Siu SC, Rivera JM, Guerrero JL, Handschumacher MD, Lethor JP, Weyman AE, Levine RA, Picard MH. Three-dimensional echocardiography. In vivo validation for left ventricular volume and function. Circulation 1993; 88:1715-23. [PMID: 8403317 DOI: 10.1161/01.cir.88.4.1715] [Citation(s) in RCA: 117] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
BACKGROUND Current two-dimensional quantitative echocardiographic methods of volume assessment require image acquisition from standardized scanning planes. Left ventricular volume and ejection fraction are then calculated by assuming ventricular symmetry and geometry. These assumptions may not be valid in distorted ventricles. Three-dimensional echocardiography can quantify left ventricular volume without the limitations imposed by the assumptions of two-dimensional methods. We have developed a three-dimensional system that automatically integrates two-dimensional echocardiographic images and their positions in real time and calculates left ventricular volume directly from traced endocardial contours without geometric assumptions. METHODS AND RESULTS To study the accuracy of this method in quantifying left ventricular volume and performance in vivo, a canine model was developed in which instantaneous left ventricular volume can be measured directly with an intracavitary balloon connected to an external column. Ten dogs were studied at 84 different cavity volumes (4 to 85 cm3) and in conditions of altered left ventricular shape produced by either coronary occlusion or right ventricular volume overload. To demonstrate clinical feasibility, 19 adult human subjects were then studied by this method for quantification of stroke volume. Left ventricular volume, stroke volume, and ejection fraction calculated by three-dimensional echocardiography correlated well with directly measured values (r = .98, .96, .96 for volume, stroke volume, and ejection fraction, respectively) and agreed closely with them (mean difference, -0.78 cm3, -0.60 cm3, -0.32%). In humans, there was a good correlation (r = .94, SEE = 4.29 cm3) and agreement (mean difference, -0.98 +/- 4.2 cm3) between three-dimensional echocardiography and Doppler-derived stroke volumes. CONCLUSIONS Three-dimensional echocardiography allows accurate assessment of left ventricular volume and systolic function.
Collapse
|
108
|
Harringer W, Fernandez-del Castillo C, Rattner DW, Guerrero JL, Warshaw AL, Vlahakes GJ. Evaluation and validation of microsphere technique for determination of pancreatic blood flow. THE AMERICAN JOURNAL OF PHYSIOLOGY 1993; 265:G587-94. [PMID: 8214079 DOI: 10.1152/ajpgi.1993.265.3.g587] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The purpose of this study was to evaluate the radiolabeled microsphere technique for pancreatic blood flow measurements. Using a canine model with an isolated pancreatic circulation, we assessed the shunting of 11- and 15-microns-diam microspheres in the pancreas, correlated pancreatic blood flow measurements obtained with the microsphere technique with those made with an ultrasonic flow probe, and determined the effects of high doses of microspheres on pancreatic blood flow and its measurement. Microspheres of 11 microns demonstrate significant shunting through the pancreatic microcirculation with underestimation of pancreatic blood flow of approximately 10% compared with results obtained with 15-microns microspheres. There is a close linear relationship between flow results obtained with 15-microns microspheres and with an ultrasonic flow probe for both the resting (r = 0.85) and the secretin-stimulated pancreas (r = 0.97). Left atrial injections of very large doses of 15-microns microspheres (50 x 10(6)) caused an acute transient reduction of pancreatic blood flow (to 39% of baseline flow) with a return to baseline values within 2 min. The accuracy of flow results and absence of physiological changes after repeated injections support the use of 15-microns microspheres for pancreatic blood flow measurements.
Collapse
|
109
|
Flachskampf FA, Rodriguez L, Chen C, Guerrero JL, Weyman AE, Thomas JD. Analysis of mitral inertance: a factor critical for early transmitral filling. J Am Soc Echocardiogr 1993; 6:422-32. [PMID: 8217209 DOI: 10.1016/s0894-7317(14)80241-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The upslope of the transmitral E wave depends on the combined influence of the rate of change of the atrioventricular gradient and the inertial mass of blood within the mitral apparatus (inertance). To use observed transmitral velocity to predict the atrioventricular pressure (delta p) difference requires knowledge of the magnitude of mitral inertance (M, inertial mass divided by effective orifice area), closely related to the length over which blood accelerates and decelerates on passing through the valve. To define the magnitude and determining factors for mitral inertance in typical valvular geometries, we used an in vitro model in which a known atrioventricular gradient (delta p, range 3.8 to 39 mm Hg) was applied instantaneously to orifices (areas of 0.5, 1, 1.5, 2, and 2.5 cm2) and conduits (volume 2.5 to 24 ml). Continuous wave Doppler spectra were recorded and the slope (dv/dt) of the tangent to the upslope was measured manually. From slope and pressure difference, inertance was calculated as delta p/(dv/dt). In 103 combinations of pressure gradients and orifices or conduits, inertance ranged between 1.9 and 12.7 gm/cm2. Linear regression showed that inertance M was highly correlated with orifice diameter D (M = 3.17 D; r = 0.84; p < 0.0001) and, in the conduits, with diameter and length L (M = 4.1 D + 0.7 L-1.8; r = 0.87; p < 0.0001). Inertance was not significantly related to the pressure gradient. In conclusion, inertance depends mainly on the mitral apparatus geometry and most strongly on orifice diameter. Knowledge of mitral inertance should help to extract quantitative data on atrioventricular pressure difference from the upslope of the transmitral E wave.
Collapse
|
110
|
Aragam JR, Main J, Guerrero JL, Vlahakes GJ, Southern JF, Adams MS, Weyman AE, Levine RA. Doppler color flow mapping of epicardial coronary arteries: initial observations. J Am Coll Cardiol 1993; 21:478-87. [PMID: 8426014 DOI: 10.1016/0735-1097(93)90692-t] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES We addressed the hypothesis that blood flow could be imaged by Doppler color flow mapping of the coronary arteries and characteristic patterns described in normal and diseased vessels. BACKGROUND Echocardiographic imaging of the epicardial coronary arteries has been suggested as a useful adjunct to their intraoperative evaluation. Addition of Doppler color flow mapping could potentially enhance this evaluation by displaying the flow disturbance produced by anatomic lesions whose physiologic significance may otherwise be uncertain. In experimental models, such displays could also potentially provide insights into the pathophysiology of coronary blood flow and stenosis. METHODS Epicardial coronary arteries were examined with a high resolution 7-MHz linear phased-array transducer both in vivo and in vitro. 1) The coronary arteries were studied in the beating hearts of 10 open chest dogs in which experimental stenoses were also created; the maximal extent of the arterial tree in which flow could be seen in the most ideal setting was also examined in four additional excised perfused canine hearts. 2) Six excised human coronary arteries were perfused in a pulsatile manner to determine whether abnormal flow patterns could be prospectively identified and subsequently correlated with pathologic evidence of stenosis. RESULTS All normal coronary artery segments studied showed homogeneous flow without evidence of flow disturbance. In the excised heart, flow could be visualized to the distal extent of the epicardial vessels; in the open chest model, visualization of the proximal 5 to 6 cm was comparable, although surrounding structures limited access to the terminal portions of the vessels. The stenotic lesions created in the canine hearts (n = 9) showed recognizable alterations in the flow pattern: localized aliasing, proximal blood flow acceleration, distal flow disturbance and recirculatory flow. In the excised human arteries, these features identified 12 lesions, all of which corresponded to areas of > or = 50% lumen narrowing by pathologic examination. CONCLUSION Blood flow in the epicardial coronary arteries can be imaged by Doppler color flow mapping and characteristic flow patterns described in normal and diseased vessels.
Collapse
|
111
|
Flachskampf FA, Weyman AE, Guerrero JL, Thomas JD. Calculation of atrioventricular compliance from the mitral flow profile: analytic and in vitro study. J Am Coll Cardiol 1992; 19:998-1004. [PMID: 1552125 DOI: 10.1016/0735-1097(92)90284-t] [Citation(s) in RCA: 56] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The quantitative assessment of ventricular diastolic function is an important goal of Doppler echocardiography. Hydrodynamic analysis predicts that the net compliance (Cn) of the left atrium and ventricle can be quantitatively predicted from the deceleration rate (dv/dt) of the mitral velocity profile by the simple expression: Cn = - A/rho dv/dt, where A is effective mitral valve area and rho is blood density. This formula was validated using an in vitro model of transmitral filling where mitral valve area ranged from 0.5 to 2.5 cm2 and net compliance from 0.012 to 0.023 cm3/(dynes/cm2) (15 to 30 cm3/mm Hg). In 34 experiments in which compliance was held constant throughout the filling period, net atrioventricular compliance was accurately calculated from the E wave downslope and mitral valve area (r = 0.95, p less than 0.0001). In a second group of experiments, chamber compliance was allowed to vary as a function of chamber pressure. When net compliance decreased during diastole (as when the ventricle moved to a steeper portion of its pressure-volume curve), the transorifice velocity profile was concave downward, whereas when net compliance increased, the velocity profile was concave upward. Application of the preceding formula to these curved profiles allowed instantaneous compliance to be calculated throughout the filling period (r = 0.93, p less than 0.001). Numeric application of a mathematic model of mitral filling demonstrated the accuracy of this approach in both restrictive and nonrestrictive orifices.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
112
|
Page RD, Harringer W, Hodakowski GT, Guerrero JL, LaRaia PJ, Austen WG, Vlahakes GJ. Determinants of maximal right ventricular function. J Heart Lung Transplant 1992; 11:90-8. [PMID: 1540618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
After heart transplantation, right ventricular failure can occur because of increased afterload. Previous studies have suggested that the maximal pressure the right ventricle can develop is determined primarily by right ventricular perfusion pressure. However, the interaction of the left ventricle and the pericardium as functional co-determinants of maximal right ventricular function is unknown. This study was undertaken to determine the interaction of the pericardium, left ventricular pressure, and right coronary artery perfusion pressure as potential determinants of maximal right ventricular function. In an acute canine preparation, with progressive pulmonary artery constriction, maximal generated right ventricular pressure was determined over a range of left ventricular systolic pressures. Additional groups of dogs were studied with the right coronary artery cannulated and were maintained at constant perfusion pressure. In all preparations, the maximal pressure the right ventricle could generate was linearly related to left ventricular systolic pressure. Having a closed pericardium markedly enhanced this effect; some effect was present with an open pericardium, although the magnitude of the influence of left ventricular pressure on maximal right ventricular pressure was much less. Maintaining constancy of right coronary artery perfusion pressure, either at high or low values, did not alter these findings nor did it alter the influence of the pericardium. These results suggest that right ventricular perfusion may not be the sole determinant of maximal right ventricular function. Furthermore, with the pericardium open, such as in the posttransplantation state, the left ventricular contribution to maximal right ventricular function may be diminished, increasing vulnerability for right ventricular failure caused by increased afterload.
Collapse
|
113
|
Hodakowski GT, Page RD, Harringer W, Jacobs EE, LaRaia PJ, Svizzero T, Guerrero JL, Austen WG, Vlahakes GJ. Ultra-pure polymerized bovine hemoglobin blood substitute: effects on the coronary circulation. BIOMATERIALS, ARTIFICIAL CELLS, AND IMMOBILIZATION BIOTECHNOLOGY : OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY FOR ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY 1992; 20:669-72. [PMID: 1391493 DOI: 10.3109/10731199209119699] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The effects of stroma-free hemoglobin (SFHgb) on the coronary circulation remain unclear. An intact canine model utilizing intracoronary adenosine to abolish the confounding effect of autoregulation was used to study maximal myocardial oxygen delivery during progressive hemodilution with polymerized bovine SFHgb. The circumflex coronary artery was instrumented with a flow probe, hydraulic constrictor, and proximal and distal catheters for adenosine infusion and distal pressure measurement, respectively. This preparation was used to generate diastolic coronary pressure-flow relations during maximal vasodilation. Maximal coronary conductance and maximal myocardial oxygen delivery were determined in two groups of 7 dogs each following hemodilution, first with 6% hetastarch (Control), followed by further hemodilution with ultra-pure, polymerized, bovine SFHgb. After hemodilution with SFHgb, maximal coronary flow increased slightly without evidence of coronary vasoconstriction. Since hemodilution with this material increases oxygen carrying capacity, maximal oxygen delivery is greater than Control, despite the very low canine hematocrit. These findings suggest: 1) SFHgb can provide adequate oxygen delivery to the myocardium despite extreme degrees of hemodilution, and 2) in this intact model, there is no evidence of adverse coronary vasomotion.
Collapse
|
114
|
Picard MH, Sanfilippo AJ, Newell JB, Rodriguez L, Guerrero JL, Weyman AE. Quantitative relation between increased intrapericardial pressure and Doppler flow velocities during experimental cardiac tamponade. J Am Coll Cardiol 1991; 18:234-42. [PMID: 2050927 DOI: 10.1016/s0735-1097(10)80245-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
To establish whether a quantitative relation exists between pericardial pressure and respiratory variation in intracardiac blood flow velocities, a spontaneously breathing closed chest canine model of pericardial tamponade was created. In seven dogs, pericardial pressure was sequentially increased in stages from a mean of -4 +/- 1 to 10 +/- 2 mm Hg while aortic and pulmonary Doppler flow velocities, pleural pressure changes (respiratory effort), blood pressure and cardiac output were measured. The variation in the Doppler-detected peak transaortic velocity (AV) during inspiration (IV) increased linearly from -5 +/- 3% at baseline (pericardial pressure -4 mm Hg) to -32 +/- 9% at a pericardial pressure of 10 mm Hg [IVAV = -2 (pericardial pressure)--13.1; r = 0.78, p less than 10(-6)]. The inspiratory variation in the peak transpulmonary velocity increased from 13 +/- 3% at baseline to 71 +/- 19% at a pericardial pressure of 10 mm Hg. The inspiratory variation in the pulmonary Doppler peak velocity (IVPV) was dependent on both pericardial pressure and degree of respiratory effort [IVPV = 3.8 (pericardial pressure) + 2.6 (respiratory effort) + 10.9; r = 0.88, p less than 10(-8)]. Thus, quantitative relations exist between increases in intrapericardial pressure and increases in inspiratory variation of peak aortic and pulmonary flow velocities. Additionally, pulmonary artery flow velocity is influenced more than aortic velocity by intrathoracic pressure.
Collapse
|
115
|
Chen C, Rodriguez L, Guerrero JL, Marshall S, Levine RA, Weyman AE, Thomas JD. Noninvasive estimation of the instantaneous first derivative of left ventricular pressure using continuous-wave Doppler echocardiography. Circulation 1991; 83:2101-10. [PMID: 2040059 DOI: 10.1161/01.cir.83.6.2101] [Citation(s) in RCA: 98] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND The complete continuous-wave Doppler mitral regurgitant velocity curve should allow reconstruction of the ventriculoatrial (VA) pressure gradient from mitral valve closure to opening, including left ventricular (LV) isovolumic contraction, ejection, and isovolumic relaxation. Assuming that the left atrial pressure fluctuation is relatively minor in comparison with the corresponding LV pressure changes during systole, the first derivative of the Doppler-derived VA pressure gradient curve (Doppler dP/dt) might be used to estimate the LV dP/dt curve, previously measurable only at catheterization (catheter dP/dt). METHODS AND RESULTS This hypothesis was examined in an in vivo mitral regurgitant model during 30 hemodynamic stages in eight dogs. Contractility and relaxation were altered by inotropic stimulation and hypothermia. The Doppler mitral regurgitant velocity spectrum was recorded along with simultaneously acquired micromanometer LV and left atrial pressures. The regurgitant velocity profiles were digitized and converted to VA pressure gradient curves using the simplified Bernoulli equation. The instantaneous dP/dt of the VA pressure gradient curve was then derived. The instantaneous Doppler-derived VA pressure gradients, instantaneous Doppler dP/dt, dP/dtmax, and -dP/dtmax were compared with corresponding catheter measurements. This method of estimating dP/dtmax from the instantaneous dP/dt curve was also compared with a previously proposed Doppler method of estimating dP/dtmax using the Doppler-derived mean rate of LV pressure rise over the time period between velocities of 1 and 3 m/sec on the ascending slope of the Doppler velocity spectrum. Both instantaneous Doppler-derived VA pressure gradients (r = 0.95, p less than 0.0001) and Doppler dP/dt (r = 0.92, p less than 0.0001) correlated well with corresponding measurements by catheter during systolic contraction and isovolumic relaxation (pooled data). The Doppler dP/dtmax (1,266 +/- 701 mm Hg/sec) also correlated well (r = 0.94) with the catheter dP/dtmax (1,200 +/- 573 mm Hg/sec). There was no difference between the two methods for measurement of dP/dtmax (p = NS). Although Doppler -dP/dtmax was slightly lower than the catheter measurement (961 +/- 511 versus 1,057 +/- 540 mm Hg/sec, p less than 0.01), the correlation between measurements by Doppler and catheter was excellent (r = 0.93, p less than 0.0001). The alternative method of mean isovolumic pressure rise (896 +/- 465 mm Hg/sec) underestimated the catheter dP/dtmax (1,200 +/- 573 mm Hg/sec) significantly (on average, 25%; p less than 0.001). CONCLUSIONS The present study demonstrated an accurate and reliable noninvasive Doppler method for estimating instantaneous LV dP/dt, dP/dtmax, and -dP/dtmax.
Collapse
|
116
|
Gold HK, Yasuda T, Jang IK, Guerrero JL, Fallon JT, Leinbach RC, Collen D. Animal models for arterial thrombolysis and prevention of reocclusion. Erythrocyte-rich versus platelet-rich thrombus. Circulation 1991; 83:IV26-40. [PMID: 2040069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Experimental animal models for erythrocyte-rich (ER) and platelet-rich (PR) arterial thrombosis were developed in dogs and rabbits and used for the evaluation of the effect of antithrombin and antiplatelet agents on thrombolysis with recombinant tissue-type plasminogen activators (rt-PA). The canine models consist of a whole blood clot produced in the left anterior descending coronary artery (ER thrombus) or a 1-cm everted (inside-out) segment graft in the circumflex coronary artery that predisposes to occlusion with PR material (PR thrombus). The rabbit models consist of a femoral arterial whole blood clot (ER thrombus) or a femoral arterial eversion graft (PR thrombus). The whole blood clot models are sensitive to recanalization with rt-PA but are consistently associated with reocclusion, notwithstanding the concomitant use of heparin and/or aspirin. Clot lysis is accelerated and reocclusion is prevented by the administration of F(ab')2 fragments of a monoclonal antibody 7E3 directed against the platelet glycoprotein IIb/IIIa receptor; of Argatroban, a synthetic thrombin inhibitor; or of kistrin, a glycoprotein IIb/IIIa-blocking polypeptide from the Malayan pit viper venom. The PR thrombus models are very resistant to recanalization with rt-PA, but this resistance can be overcome by the concomitant use of the platelet glycoprotein IIb/IIIa-blocking antibody. Thus, selective platelet glycoprotein IIb/IIIa inhibitors are more effective than aspirin, heparin, or both in accelerating arterial thrombolysis with rt-PA; in preventing reocclusion after clot lysis; and in overcoming the resistance of PR thrombus to dispersion with rt-PA. These experimental animal models may be useful in the development of improved thrombolytic strategies using plasminogen activators in conjunction with specifically targeted antiplatelet and anticoagulant agents.
Collapse
|
117
|
O'Shea JP, Southern JF, D'Ambra MN, Magro C, Guerrero JL, Marshall JE, Vlahakes GV, Levine RA, Weyman AE. Effects of prolonged transesophageal echocardiographic imaging and probe manipulation on the esophagus--an echocardiographic-pathologic study. J Am Coll Cardiol 1991; 17:1426-9. [PMID: 2016462 DOI: 10.1016/s0735-1097(10)80158-5] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Transesophageal echocardiography is being increasingly utilized in the operating room and intensive care and ambulatory settings. However, to date no data are available concerning possible trauma of the transesophageal echocardiographic technique to the esophagus due to probe insertion, manipulation or direct ultrasound energy transmission. To test the hypothesis that transesophageal manipulations caused no traumatic or thermal injury to the esophageal mucosa, 12 animals were studied with continuous transesophageal echocardiography for a period of variable duration (mean 4.6 h +/- 51 min). The study group consisted of four monkeys (mean weight 5.7 +/- 0.6 kg and eight mongrel dogs (mean weight 29.8 +/- 1.4 kg). The eight dogs were studied during right heart bypass with full heparinization for 6.6 +/- 0.2 h, whereas the four monkeys were studied for 60 to 90 min in the absence of cardiopulmonary bypass and anticoagulation. Immediately after completion of transesophageal echocardiography in each case, the esophagus was entirely excised. Detailed macroscopic and microscopic examination of the esophagus revealed no significant mucosal or thermal injury. This preliminary animal study suggests that transesophageal echocardiography is safe for the esophageal mucosa in animals as small as 5 kg in weight, despite prolonged use and in the presence of systemic anticoagulation.
Collapse
|
118
|
Garabedian HD, Gold HK, Leinbach RC, Svizzero TA, Finkelstein DM, Guerrero JL, Collen D. Bleeding time prolongation and bleeding during infusion of recombinant tissue-type plasminogen activator in dogs: potentiation by aspirin and reversal with aprotinin. J Am Coll Cardiol 1991; 17:1213-22. [PMID: 1706738 DOI: 10.1016/0735-1097(91)90856-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Thrombolytic therapy is associated with a bleeding tendency that may be exacerbated by adjunctive antiplatelet agents. The effect of recombinant tissue-type plasminogen activator (rt-PA) alone or in combination with aspirin on serial measurements of template bleeding time, ex vivo platelet aggregation and coagulation factors and the frequency of bleeding was studied in dogs. During infusion of rt-PA (15, 30 or 60 micrograms/kg per min for 90 min), a dose-related increase in bleeding time was observed. In a randomized blinded study of 25 dogs, the baseline bleeding time (mean +/- SD) was 3.5 +/- 1 min in control animals and 4 +/- 2 min after oral aspirin (15 mg/kg body weight). Infusion of rt-PA (15 micrograms/kg per min for 90 min) prolonged the bleeding time to a maximum of 15 +/- 12 min. In contrast, combined aspirin and rt-PA therapy produced an increase to greater than 30 min during infusion, reverting to 13 +/- 10 min within 2 h after cessation of infusion. Recurrent continuous bleeding from incision sites occurred in one of six dogs given aspirin alone, two of seven given rt-PA alone and all six dogs given both aspirin and rt-PA (p = 0.02). Bleeding time greater than 9 min correlated significantly with bleeding frequency (p less than 0.0001), with a sensitivity of 100% and a specificity of 87%. Intravenous bolus injection of aprotinin (20,000 kallikrein inhibitor units/kg body weight) in six dogs given both rt-PA and aspirin produced a decrease in bleeding time from greater than 30 min to 9.5 +/- 9 min and resulted in cessation of bleeding. Thus, bleeding and bleeding time prolongation in this canine model are potentiated by a marked interactive effect of rt-PA and aspirin that is rapidly reversible. Template bleeding times may provide a useful quantitative index for monitoring the bleeding tendency associated with thrombolytic therapy.
Collapse
|
119
|
Yasuda T, Gold HK, Leinbach RC, Saito T, Guerrero JL, Jang IK, Holt R, Fallon JT, Collen D. Lysis of plasminogen activator-resistant platelet-rich coronary artery thrombus with combined bolus injection of recombinant tissue-type plasminogen activator and antiplatelet GPIIb/IIIa antibody. J Am Coll Cardiol 1990; 16:1728-35. [PMID: 2123910 DOI: 10.1016/0735-1097(90)90327-l] [Citation(s) in RCA: 87] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Resistance of coronary occlusive thrombus to thrombolytic therapy, found in some patients with acute myocardial infarction, may be due to the presence of platelet-rich coronary clot. Reperfusion therapy in such patients may require the development and evaluation of alternative strategies in animal models. Therefore, platelet-rich coronary artery thrombus was developed by excision, eversion (inside out) and reanastomosis of a 1 cm segment of the left circumflex coronary artery in anesthetized dogs maintained on heparin antiocoagulation. Blood flow was restored in 25 of 27 dogs. Thrombotic occlusion of the everted segment graft with primarily platelet-rich thrombus or thrombus containing platelet-rich and erythrocyte-rich zones, persisting for at least 30 min, occurred within 4.5 +/- 3.5 min (mean +/- SD) in 20 of these 25 dogs. In 5 of these 20 dogs (group I, control), stable occlusion, as monitored with an ultrasound flow probe and coronary angiography, was maintained during a 2 h observation period. In group II (n = 5), intravenous bolus injections of recombinant tissue-type plasminogen activator (rt-PA) at a dose of 0.45 mg/kg body weight at four 15 min intervals did not cause reperfusion in four dogs and produced cyclic reperfusion and reocclusion in one dog. In group III (n = 5), a single intravenous bolus injection of 0.8 mg/kg of the F(ab')2 fragment of a murine monoclonal antibody (7E3) against the human platelet GPIIb/IIIa receptor [7E3-F(ab')2] produced stable reperfusion in two of the five dogs, whereas occlusion persisted in the other three. In group IV (n = 5), injection of 7E3-F(ab')2 (0.8 mg/kg) followed by rt-PA (0.45 mg/kg) caused stable reperfusion without reocclusion in all dogs (p less than 0.05 versus rt-PA alone and p less than 0.01 versus control). This study confirms that platelet-rich occlusive coronary thrombus is very resistant to lysis with intravenous rt-PA. However, this resistance may be overcome by the combined use of a reduced dose of rt-PA and the antiplatelet GPIIb/IIIa receptor antibody 7E3. The results indicate that platelet-rich thrombus resistant to thrombolytic agents may be dispersed pharmacologically without resort to mechanical recanalization. The present dog model may be useful in investigating specific strategies for the dispersion of resistant platelet-rich coronary thrombus.
Collapse
|
120
|
Yasuda T, Gold HK, Yaoita H, Leinbach RC, Guerrero JL, Jang IK, Holt R, Fallon JT, Collen D. Comparative effects of aspirin, a synthetic thrombin inhibitor and a monoclonal antiplatelet glycoprotein IIb/IIIa antibody on coronary artery reperfusion, reocclusion and bleeding with recombinant tissue-type plasminogen activator in a canine preparation. J Am Coll Cardiol 1990; 16:714-22. [PMID: 2117620 DOI: 10.1016/0735-1097(90)90364-u] [Citation(s) in RCA: 102] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The comparative effects of intravenous aspirin, the synthetic thrombin inhibitor (2R,4R)-4-methyl-1-[N2-(3-methyl-1,2,3,4-tetrahydro-8- quinolinesulfonyl)-L-arginyl]-2-piperidinecarboxylic acid monohydrate (Argatroban) and F(ab')2 fragments of monoclonal antibody 7E3 against platelet glycoprotein IIb/IIIa (7E3-F[ab']2) on thrombolysis, reocclusion and bleeding associated with 0.45 mg/kg body weight bolus injections of recombinant tissue-type plasminogen activator (rt-PA) were studied in a canine coronary artery thrombosis model. Coronary patency was monitored for 2 h both by flow probe and by coronary angiography. Four groups were studied: Group I = pretreated with 17 mg/kg intravenous aspirin (n = 6), Group II = pretreated with 200 micrograms/kg per min intravenous Argatroban for 60 min (n = 5), Group III = pretreated with aspirin and Argatroban (n = 5) and Group IV = pretreated with 0.8 mg/kg intravenous 7E3-F(ab')2 (n = 5). In Group I, reflow occurred in four of six dogs, but did not persist; reflow was induced in Group II in four of five dogs, persisting in one; in Group III, reflow occurred in all five dogs, persisting in four; in Group IV reflow was achieved in four of five dogs, persisting in two. The frequency of persistent reflow in Group III was significantly higher than in the combined Groups I and II (p = 0.012), whereas the time to reflow was significantly shorter in the groups receiving Argatroban than in the aspirin group (median 25 versus 55 min, p = 0.04). There were no significant differences between Groups III and IV.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
121
|
Flachskampf FA, Weyman AE, Guerrero JL, Thomas JD. Influence of orifice geometry and flow rate on effective valve area: an in vitro study. J Am Coll Cardiol 1990; 15:1173-80. [PMID: 2312974 DOI: 10.1016/0735-1097(90)90260-v] [Citation(s) in RCA: 90] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Fluid dynamics suggests that orifice geometry is a determinant of discharge properties and, therefore, should influence empiric constants in formulas (such as the Gorlin formula) to calculate stenotic valve area. An in vitro study utilizing a model of transmitral flow was conducted to investigate how the discharge coefficient changes with 1) orifice eccentricity (ratio of long to short diameter), 2) absolute area, 3) the presence of a nozzle-like inlet, and 4) varying flow. Twenty-three orifices with areas varying between 0.3 and 2.5 cm2 and eccentricities from 1:1, or circular, to 5:1, or elliptic, were tested. The calculated discharge coefficients ranged between 0.675 and 0.93. For a given area, the discharge coefficient decreased by a mean value (+/- SD) of 5.5 +/- 1.3% between circular orifices and 5:1 ellipses. Discharge coefficients increased by a mean of 8.9 +/- 3.5% from 0.3 to 2.5 cm2 area within each eccentricity class. A gradually tapering inlet (nozzle) raised the discharge coefficient by 8.8 +/- 3.9%, leading to a discharge coefficient between 0.81 and 0.93 for round orifices. The discharge coefficient did not change appreciably with flow. The concept of the discharge coefficient and its role in assessing restrictive orifices in general by hydraulic formulas (for example, the Gorlin and pressure half-time calculations) are discussed.
Collapse
|
122
|
Quyyumi AA, Iaffaldano R, Guerrero JL, Ryan CA, Powell WJ, Axelrod L. Prostacyclin and pathogenesis of hemodynamic abnormalities of diabetic ketoacidosis in rats. Diabetes 1989; 38:1585-94. [PMID: 2511053 DOI: 10.2337/diab.38.12.1585] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The pathogenesis of the hemodynamic abnormalities of diabetic ketoacidosis (DKA) is not well understood. Previous studies suggest that prostacyclin (PGI2) production by adipose tissue is increased in DKA. We investigated the role of PGI2 in the pathogenesis of the reduced vascular resistance in DKA. Rats with streptozocin-induced DKA were anesthetized with pentobarbital sodium, and flow was measured with an electromagnetic probe on the infradiaphragmatic aorta. The plasma level of 6-keto-PGF1 alpha (stable derivative of PGI2) was higher (mean +/- SE 0.91 +/- 0.05 ng/ml) and vascular resistance lower (4.9 +/- 0.2 mmHg.ml-1.min-1.100 g-1 [resistance units, RU]) in 67 rats with DKA than in 21 normal rats (0.34 +/- 0.03 ng/ml, P less than .01, and 9.0 +/- 0.7 RU, P less than .01, respectively). Inhibition of cyclooxygenase activity with either indomethacin or meclofenamic acid reduced the plasma 6-keto-PGF1 alpha level but failed to raise vascular resistance. Infusions of PGI2 in rats with DKA demonstrated that the vasculature was responsive to PGI2. Inhibition of cyclooxygenase activity not only reduced PGI2 production but also suppressed renin release. When the effects of the renin-angiotensin system were excluded by bilateral nephrectomy, indomethacin caused a significant increase (P less than .05) in vascular resistance. Thus, the failure of cyclooxygenase inhibitors to raise vascular resistance in DKA was a result of concurrent suppression of vasodilator (PGI2) and vasoconstrictor (renin-angiotensin system) mechanisms that are activated in DKA. Insulin administration increased vascular resistance (P less than .01) and decreased the level of plasma 6-keto-PGF1 alpha (P less than .01). Combined administration of PGI2 and insulin did not alter vascular resistance, suggesting that the increase in vascular resistance with insulin was predominantly due to the reduction of circulating PGI2. Thus, vascular resistance is decreased in DKA primarily as a result of the vasodilator effects of PGI2 produced by adipose tissue. The activation of the renin-angiotensin system represents a partial compensation. The increase in PGI2 production may contribute to the hypotension and mortality of DKA.
Collapse
|
123
|
Force T, Malis CD, Guerrero JL, Varadarajan GS, Bonventre JV, Weber PC, Leaf A. n-3 fatty acids increase postischemic blood flow but do not reduce myocardial necrosis. THE AMERICAN JOURNAL OF PHYSIOLOGY 1989; 257:H1204-10. [PMID: 2801980 DOI: 10.1152/ajpheart.1989.257.4.h1204] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The effects of a fish oil-supplemented diet on infarct size and regional myocardial blood flow were examined in a rat model of acute ischemia followed by reperfusion. Thirty-five rats were fed a diet containing 20% by weight: fish oil (FO), rich in n-3 polyunsaturated fatty acids; corn oil (CO), with predominantly n-6 polyunsaturated fatty acids; or beef tallow (BT), containing large amounts of saturated fatty acids. After 6-12 wk on the diet, animals underwent 40 min of left coronary artery occlusion followed by 2 h of reperfusion. Regional transmural myocardial blood flow was determined with radioactive microspheres at 30 min of occlusion and again 30 min after reperfusion. Infarct size was determined with triphenyltetrazolium chloride. Blood flow was virtually undetectable within the ischemic zone in all groups during occlusion. With reperfusion, however, ischemic zone absolute blood flow and relative flow (normalized to nonischemic zone flow) were significantly greater in the fish oil group [2.4 +/- 0.25 ml.min-1.g-1, 44 +/- 4% vs. 1.7 +/- 0.3, 29 +/- 5% for CO (P less than 0.05 vs. FO), and 1.4 +/- 0.3, 29 +/- 5% for BT (P less than 0.05 vs. FO)]. Despite differences in reperfusion blood flow, average percent transmural extent of infarction was nearly identical (68 +/- 4, 68 +/- 5, and 64 +/- 3%) and overall infarct size was similar (38 +/- 3, 36 +/- 4, and 29 +/- 3%) for FO, CO, and BT groups, respectively. In conclusion, dietary supplementation with fish oils increases postischemic blood flow but has no effect on extent of myocardial infarction in this ischemia-reperfusion model in rats.
Collapse
|
124
|
Yasuda T, Gold HK, Fallon JT, Leinbach RC, Garabedian HD, Guerrero JL, Collen D. A canine model of coronary artery thrombosis with superimposed high grade stenosis for the investigation of rethrombosis after thrombolysis. J Am Coll Cardiol 1989; 13:1409-14. [PMID: 2495318 DOI: 10.1016/0735-1097(89)90319-7] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
A canine model was developed to investigate coronary artery thrombolysis and reocclusion in the setting of endothelial cell damage and fixed stenosis, which simulate anatomic features occurring in patients with acute myocardial infarction. In open chest dogs, endothelial cell damage was produced in the left anterior descending coronary artery by external compression with blunt forceps, greater than 90% stenosis was obtained by an external constrictor and thrombosis was induced by instillation of thrombin and fresh blood in an isolated arterial segment. In the absence of stenosis, intravenous infusion of 750,000 U of streptokinase over 1 h caused reperfusion in five of six dogs in 34 +/- 25 min (mean +/- SD). Urokinase, 600,000 U intravenously over 30 min followed by 600,000 U over 30 min by the intracoronary route, induced reperfusion in three of four dogs in 65 +/- 23 min. Recombinant two chain tissue-type plasminogen activator (rt-PA) (G11021), infused intravenously at a rate of 15 micrograms/kg per min for 30 min or until reflow, induced reperfusion in all 12 dogs in 28 +/- 13 min. In the absence of coronary artery stenosis, spontaneous reocclusion did not occur within 2 h after the end of the infusion. In the presence of the coronary artery constrictor, which reduced the blood flow to 40 +/- 10% of baseline, streptokinase, urokinase and rt-PA caused coronary thrombolysis to proceed at comparable or only slightly slower rates. Cyclical reocclusion during or after the end of infusion of these thrombolytic agents, caused by platelet-rich thrombus, was almost invariably observed, generally within 30 min after the onset of reperfusion.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
125
|
Ziskind AA, Gold HK, Yasuda T, Kanke M, Guerrero JL, Fallon JT, Saito T, Collen D. Synergistic combinations of recombinant human tissue-type plasminogen activator and human single-chain urokinase-type plasminogen activator. Effect on thrombolysis and reocclusion in a canine coronary artery thrombosis model with high-grade stenosis. Circulation 1989; 79:393-9. [PMID: 2492455 DOI: 10.1161/01.cir.79.2.393] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The synergistic effects of recombinant human tissue-type plasminogen activator (rt-PA) and single-chain urokinase-type plasminogen activator (scu-PA) on coronary arterial thrombolysis were investigated in open-chest dogs with thrombosis of the left anterior descending coronary artery and a superimposed high-grade stenosis. A 90% stenosis was generated by external constriction, reducing blood flow to 40 +/- 10% of baseline. Localized thrombosis was produced by endothelial cell injury and instillation of thrombin and fresh blood. Intravenous infusion for 60 minutes of either 30 micrograms/kg/min rt-PA alone or 10 micrograms/kg/min scu-PA alone consistently produced coronary artery recanalization (six of eight dogs and five of five dogs, respectively) but was almost always associated with reocclusion during or shortly after the end of the infusion (four of six dogs and five of five dogs, respectively). Infusion of either 15 micrograms/kg/min rt-PA or 5 micrograms/kg/min scu-PA for 60 minutes did not cause coronary artery recanalization (none of four dogs in each group). Combined infusion of 7.5 micrograms/kg/min rt-PA and 2.5 micrograms/kg/min scu-PA for 60 minutes (one fourth of the minimum thrombolytic dose of each agent) induced coronary artery recanalization (six of six dogs) but was also associated with early reocclusion (six of six dogs). Combined infusion of 3.75 micrograms/kg/min rt-PA and 1.25 micrograms/kg/min scu-PA for 60 minutes did not consistently cause recanalization (one of four dogs). Combined infusion of 15 micrograms/kg/min rt-PA and 5 micrograms/kg/min scu-PA for 60 minutes caused recanalization in all of six dogs but was associated with reocclusion in all six.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
126
|
Choong CY, Abascal VM, Thomas JD, Guerrero JL, McGlew S, Weyman AE. Combined influence of ventricular loading and relaxation on the transmitral flow velocity profile in dogs measured by Doppler echocardiography. Circulation 1988; 78:672-83. [PMID: 3409503 DOI: 10.1161/01.cir.78.3.672] [Citation(s) in RCA: 327] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The relation of the Doppler transmitral flow velocity profile to left ventricular loading conditions and diastolic properties remains poorly described. We studied seven adult mongrel dogs with an open-chest right heart bypass model in which left atrial pressure, representing preload, was varied by controlling blood flow into the pulmonary artery and left ventricular systolic pressure, representing afterload, was controlled independently by pumping blood into or from the femoral arteries. Heart rate was kept constant by crushing the sinus node and pacing the right atrium. Mitral inflow velocity profiles were measured by pulsed-wave Doppler echocardiography at multiple left atrial and left ventricular systolic pressures. In individual dogs, the peak E-wave velocity increased linearly with increasing left atrial V-wave pressure at constant left ventricular systolic pressure and decreased with increasing left ventricular systolic pressure at constant left atrial pressure. Stepwise multiple linear regression analysis of data pooled from all experimental stages in all dogs identified left atrial V-wave pressure, the time constant of relaxation (TL), and left ventricular systolic pressure, in order of decreasing significance, as predictors of the peak E-wave velocity (n = 82, multiple r = 0.87, p less than 0.0001). Multivariate analysis with the same three factors in individual dogs yielded higher r values (mean r = 0.89; range, 0.85-0.97), suggesting the presence of important interdog differences that were not accounted for by these three factors alone. When the values of codeterminant hemodynamic factors were kept within narrower limits, correlations between peak E-wave velocity and left atrial V-wave pressure (n = 35, multiple r = 0.83, p less than 0.0001), TL (n = 76, multiple r = -0.54, p less than 0.0001) and left ventricular systolic pressure (n = 20, multiple r = -0.59, p less than 0.005) improved substantially. In the pooled data, the relation of the peak E-wave velocity to left atrial V-wave pressure was shifted downward by an increase in TL (reduced relaxation rate), and the relation of the peak E-wave velocity to TL was shifted upward by an increase in left atrial V-wave pressure. Multivariate analysis also selected left atrial V-wave pressure and TL as the two most significant correlates of the velocity-time integral and deceleration rate of the E wave.(ABSTRACT TRUNCATED AT 400 WORDS)
Collapse
|
127
|
Camazine B, Shannon RP, Guerrero JL, Graham RM, Powell WJ. Neurogenic histaminergic vasodilation in canine skeletal muscle: mediation by alpha 2-adrenoceptor stimulation. Circ Res 1988; 62:871-83. [PMID: 3359574 DOI: 10.1161/01.res.62.5.871] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This study examines the neurogenic effect of alpha 2-adrenoceptor stimulation on skeletal muscle vascular resistance and its relation to the level of background sympathetic activity. The isolated, separately perfused, neurally intact canine gracilis muscle preparation was used since it permits deliberate and quantifiable alterations in background sympathetic activity, as measured by skeletal muscle vascular resistance. Systemic intravenous UK-14304, a highly selective alpha 2-adrenoceptor agonist, produced a precipitous, neurogenic vasodilation that lowered vascular resistance below the subsequently denervated resistance, thus indicating that an active vasodilation was involved. The overall magnitude of the vasodilation was much greater in animals that had been hemorrhaged to elevate background sympathetic activity than in animals that had been transfused to lower background activity. The neurogenic vasodilation was unaffected by baroreceptor and cardiopulmonary receptor denervation and by prior cholinergic-receptor blockade of the gracilis muscle. Prior H1- and H2-histaminergic-receptor blockade, on the other hand, eliminated the active vasodilation but not a vasodilation down to the subsequently denervated resistance. Prior alpha 1-adrenoceptor blockade lowered resistance down to the subsequently denervated resistance and greatly attenuated the active vasodilation. The present study demonstrates that withdrawal of sympathetic activity by alpha 2-adrenoceptor stimulation produces an active vasodilation resulting from histamine release in skeletal muscle as well as a passive vasodilation resulting from lysis of peripheral vasoconstrictor tone.
Collapse
|
128
|
Yasuda T, Gold HK, Fallon JT, Leinbach RC, Guerrero JL, Scudder LE, Kanke M, Shealy D, Ross MJ, Collen D, Coller BS. Monoclonal antibody against the platelet glycoprotein (GP) IIb/IIIa receptor prevents coronary artery reocclusion after reperfusion with recombinant tissue-type plasminogen activator in dogs. J Clin Invest 1988; 81:1284-91. [PMID: 2832448 PMCID: PMC329660 DOI: 10.1172/jci113446] [Citation(s) in RCA: 187] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Localized thrombosis was produced in the left anterior descending (LAD) coronary artery of open chest dogs by constricting a segment so as to produce greater than 90% stenosis (reducing blood flow to 40 +/- 10% of baseline), and placing a thrombus in the segment immediately proximal to the stenosis by inducing endothelial cell injury and instilling a mixture of blood and thrombin. Intravenous infusion of recombinant tissue-type plasminogen activator (rt-PA) at a rate of 15-30 micrograms/kg per min for 30 or 60 min in eight dogs induced coronary artery reperfusion within 23 +/- 7 min (mean +/- SD), but reocclusion occurred despite heparin anticoagulation in all but one of these dogs within 7 +/- 5 min. Intravenous injection of 0.8 mg/kg of the F(ab')2 fragment of a monoclonal antibody (7E3) directed against the platelet GPIIb/IIIa receptor, prevented reocclusion in 10/10 dogs during an observation period of 2 h (P less than 0.001 vs. rt-PA alone). The antibody abolished ADP-induced platelet aggregation and markedly prolonged the bleeding time. Intravenous aspirin or dipyridamole prevented reocclusion for 1 h or more in only 2/7 and 1/6 dogs, respectively. We conclude that the monoclonal antibody is very effective in preventing reocclusion after successful thrombolysis of occluded coronary arteries with rt-PA.
Collapse
|
129
|
Gold HK, Coller BS, Yasuda T, Saito T, Fallon JT, Guerrero JL, Leinbach RC, Ziskind AA, Collen D. Rapid and sustained coronary artery recanalization with combined bolus injection of recombinant tissue-type plasminogen activator and monoclonal antiplatelet GPIIb/IIIa antibody in a canine preparation. Circulation 1988; 77:670-7. [PMID: 3124974 DOI: 10.1161/01.cir.77.3.670] [Citation(s) in RCA: 320] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The effects of bolus injections of recombinant single-chain tissue-type plasminogen activator (rt-PA) and of F(ab')2 fragments of a murine monoclonal antibody (7E3) against the human platelet GPIIb/IIIa receptor [7E3-F(ab')2] on coronary arterial thrombolysis and reocclusion was studied in a canine preparation of coronary artery thrombosis superimposed on high-grade stenosis. Bolus intravenous injections of rt-PA at a dose of 0.45 mg/kg, repeated at 15 min intervals until reperfusion occurred (maximum of four injections) caused reperfusion in five of seven dogs within 100 min (33 +/- 15 min, mean +/- SD). Reperfusion was rapidly followed (generally within 10 min) by reocclusion and then by periods of cyclical reflow and reocclusion. A single intravenous injection of 7E3-F(ab')2 alone at 0.8 mg/kg caused reperfusion within 100 min in two of six dogs (19 and 37 min) without subsequent reocclusion. Single bolus injections of different amounts (0.1 to 0.8 mg/kg) of 7E3-F(ab')2 were then combined with bolus injections of 0.45 mg/kg of rt-PA. Stable reperfusion without reocclusion was accomplished with 0.8 or 0.6 mg/kg 7E3-F(ab')2 and a single injection of 0.45 mg/kg rt-PA within 6 +/- 3 min (n = 6, p less than .01) and 8 +/- 5 min (n = 5, p less than .02), respectively. None of these animals suffered reocclusion of the coronary artery. Lower doses (0.1 to 0.2 mg/kg) of 7E3-F(ab')2 did not significantly shorten the time to reperfusion and did not prevent reocclusion.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
130
|
Rediker DE, Guerrero JL, Block DS, Southern JF, Fallon JT, Block PC. Limits of mitral valve apparatus distensibility: observations from balloon mitral valvotomy in a canine model. Am Heart J 1987; 114:1513-5. [PMID: 3687703 DOI: 10.1016/0002-8703(87)90557-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
131
|
O'Keefe RJ, Domalik-Wawrzynski L, Guerrero JL, Rosow CE, Lowenstein E, Powell WJ. Local and neurally mediated effects of sufentanil on canine skeletal muscle vascular resistance. J Pharmacol Exp Ther 1987; 242:699-706. [PMID: 2886649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The present study examines both the local and neurally mediated effects of sufentanil, a new synthetic opioid, on the vascular resistance of the isolated, separately perfused canine gracilis muscle. Infusions (50 micrograms/min) of sufentanil into the gracilis arteries of nine denervated gracilis muscles did not produce a direct vascular effect. Because morphine has been previously shown to produce a central sympatholytic effect, the neural effect of sufentanil was examined in 12 innervated muscles under conditions of either low or high background sympathetic activity produced by either hemorrhage or transfusion of the dog. After i.v. sufentanil (20 micrograms/kg), all dogs experienced a rapid parallel fall in gracilis vascular resistance (GVR) and mean arterial pressure. The GVR decreased under conditions of high and low sympathetic activity. With low sympathetic tone, the GVR decreased from a control value of 24.1 +/- 4.4 S.E.M. to 6.6 +/- 0.8 resistance units (RU), a value below the subsequently denervated level (13.2 +/- 2.5 RU) (P less than .05). In hemorrhaged animals with elevated control sympathetic tone, resistance declined from 38.4 +/- 9.1 to 26.1 +/- 4.4 RU (P less than .05) but did not reach the denervated level (12.4 +/- 2.7 RU). Local intra-arterial pharmacologic blockade of the gracilis muscle was performed in animals with low sympathetic tone. Intra-arterial atropine did not effect the neurogenic vasodilatory response to sufentanil, whereas prazosin abolished it. Intra-arterial H1 and H2 receptor blockade prevented the decline of GVR secondary to sufentanil below the denervated level. Thus, vasodilation associated with sufentanil administration is mediated solely through neurogenic mechanisms.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
132
|
Kaul S, Pandian NG, Guerrero JL, Gillam LD, Okada RD, Weyman AE. Effects of selectively altering collateral driving pressure on regional perfusion and function in occluded coronary bed in the dog. Circ Res 1987; 61:77-85. [PMID: 3608113 DOI: 10.1161/01.res.61.1.77] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
To determine whether selectively altering the coronary perfusion pressure in the adjacent nonoccluded vessel has any influence on the occluded bed, the effects of alterations in the perfusion pressure of the left anterior descending coronary artery on the perfusion and function of the acutely occluded left circumflex coronary (LC) arterial bed were studied in 10 anesthetized open-chest dogs. Radiolabelled microsphere-assessed regional myocardial perfusion and endocardial excursion determined by two-dimensional echocardiography were measured during control conditions prior to mid-LC occlusion with left anterior descending coronary arterial pressure (LADP) equal to aortic pressure (AoP) (Stage 0) and to 3 randomly performed postocclusion stages. At each postocclusion stage, the perfusion territory of the occluded LC bed (area at risk) was measured in vivo using myocardial contrast two-dimensional echocardiography. During Stage 1 (LADP = AoP), area at risk was 5.1 +/- 0.9 cm2 (x +/- 1 SD) and transmural blood flow to the LC arterial bed decreased from 0.96 +/- 0.50 ml/min/g (Stage 0) to 0.16 +/- 0.12 ml/min/g (p less than 0.01), while endocardial excursion decreased from 28.0 +/- 9.0% to 2.0 +/- 10.0% (p less than 0.01). During Stage 2 (LADP greater than AoP), area at risk decreased to 4.4 +/- 1.0 cm2 compared with Stage 1 (p less than 0.01), and transmural blood flow, endocardial:epicardial blood flow ratio, and endocardial excursion increased to 0.51 +/- 0.39 ml/min/g, 0.64 +/- 0.20, and 14 +/- 6%, respectively (p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
133
|
Guyer DE, Foale RA, Gillam LD, Wilkins GT, Guerrero JL, Weyman AE. An echocardiographic technique for quantifying and displaying the extent of regional left ventricular dyssynergy. J Am Coll Cardiol 1986; 8:830-5. [PMID: 3760356 DOI: 10.1016/s0735-1097(86)80424-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A convenient noninvasive method of mapping the left ventricular endocardial surface has been developed that can be used to display regional dysfunction and calculate the total area of abnormal endocardial excursion from data obtained in two orthogonal apical and three or more short-axis cross-sectional echocardiographic images. Visually identified regions of abnormal systolic function are plotted on end-diastolic, planar endocardial surface maps, and the extent of dysfunction can be expressed either as an absolute area or as a fraction of the total endocardial surface area involved. The extent of the left ventricular surface moving abnormally, calculated with this echocardiographic mapping technique, was compared with two histochemical measures of infarct size in a series of 11 closed chest dogs with acute circumflex coronary artery occlusions. Overall extent of abnormally moving left ventricular wall correlated closely with both the fraction of the endocardial area overlying infarct (r = 0.92, p less than or equal to 0.001) and the fraction of the myocardial volume infarcted (r = 0.86, p less than or equal to 0.001). This suggests that the echocardiographic mapping technique can be used to accurately quantify the global extent of abnormal systolic function in the presence of regional wall motion abnormalities.
Collapse
|
134
|
Guyer DE, Gibson TC, Gillam LD, King ME, Wilkins GT, Guerrero JL, Weyman AE. A new echocardiographic model for quantifying three-dimensional endocardial surface area. J Am Coll Cardiol 1986; 8:819-29. [PMID: 3760355 DOI: 10.1016/s0735-1097(86)80423-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A new technique for quantitatively mapping the three-dimensional left ventricular endocardial surface was developed, using measurements from standard cross-sectional echocardiographic images. To validate the accuracy of this echocardiographic mapping technique in an animal model, the endocardial areas of 15 excised canine ventricles were calculated using measurements made from echocardiographic studies of the hearts and compared with areas determined with latex casts of the same ventricles. Close correlation (r = 0.87, p less than 0.001) between these two measures of endocardial area provided preliminary confirmation of the accuracy of the maps. To further characterize the mapping algorithm, it was translated into computer format and used to map the surfaces of idealized hemiellipsoids. Areas measured with this mapping technique closely approximated the actual areas of idealized surfaces with a wide spectrum of shapes; maps were particularly accurate for ellipsoids with shapes similar to those of undistorted human ventricles. Also, the accuracies of area calculations were relatively insensitive to deviation from the assumed positions of the echocardiographic short-axis planes. Finally, although the accuracy of the mapping technique improved as data from more transverse planes were added, the procedure proved reliable for estimating surface areas when data from only three planes were used. These studies confirm the accuracy of the echocardiographic mapping technique, and they suggest that the resulting planar plots might be useful as templates for localizing and quantifying the overall extent of abnormal wall motion.
Collapse
|
135
|
Stewart WJ, Jiang L, Mich R, Pandian N, Guerrero JL, Weyman AE. Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations. J Am Coll Cardiol 1985; 6:653-62. [PMID: 4031277 DOI: 10.1016/s0735-1097(85)80127-3] [Citation(s) in RCA: 164] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Doppler echocardiographic methods for measuring volumetric flow through the aortic, pulmonary and mitral valves provide the cardiologist with several potentially interchangeable noninvasive methods for determining cardiac output. In addition, comparison of flow differences through individual valves offers the potential to quantitate shunt flow and regurgitant volumes. To date, however, no study has compared the relative accuracies of each of these flow measurements in a controlled experimental setting. Therefore, in this study, Doppler echocardiography was used to measure aortic, pulmonary and mitral valve flows in seven open chest dogs on right atrial bypass where forward cardiac output was precisely controlled with a roller pump. Correlations with roller pump output were better for Doppler measurements of aortic (r = 0.98, SD = 0.3) and mitral (r = 0.97, SD = 0.3) than for pulmonary (r = 0.93, SD = 0.5) valve flow. Interobserver reproducibility was also better for aortic (r = 0.94) and mitral (r = 0.97) than for pulmonary (r = 0.88) valve flow measurements. All valves showed flow-related increases in cross-sectional area, but the slope of this response was variable: 0.05, 0.16 and 0.21 for the aortic, the pulmonary and the mitral valve, respectively. Increased forward flow through the aortic valve, therefore, was manifested primarily by an increase in velocity, whereas increasing flow through the pulmonary and mitral valves produced more significant area changes with correspondingly smaller increases in the velocity component. Recalculation of Doppler-determined outputs, assuming a fixed valve area for the entire range of flows, resulted in a decreased correlation with roller pump output. Both velocity and valve area should be measured at each flow rate for greatest accuracy in volumetric flow calculations.
Collapse
|
136
|
Gillam LD, Kaul S, Fallon JT, Levine RA, Hedley-Whyte ET, Guerrero JL, Weyman AE. Functional and pathologic effects of multiple echocardiographic contrast injections on the myocardium, brain and kidney. J Am Coll Cardiol 1985; 6:687-94. [PMID: 4031282 DOI: 10.1016/s0735-1097(85)80132-7] [Citation(s) in RCA: 59] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Myocardial contrast echocardiography can define in vivo the area at risk for necrosis after coronary occlusion. However, if this technique is to be used, it cannot be intrinsically toxic to the heart or other critical organs. To determine the functional and pathologic effects of contrast echocardiography, six intracoronary, six intrarenal and six intracarotid artery injections of 2 to 6 cc of a commonly employed contrast agent (agitated Renografin-saline solution) were performed in five dogs. A sixth dog served as a sham to assess any deleterious effects of the model preparation. Two-dimensional echocardiographic images and electrocardiograms were recorded during intracoronary injections, and heart rate, blood pressure, left ventricular end-diastolic pressure and rate of rise of left ventricular pressure (dP/dt) were continuously monitored. At 24 hours, echocardiographic and hemodynamic measurements were repeated, the dogs were killed and the heart, brain and kidneys were removed and prepared for light microscopic examination. Quantitative analysis of left ventricular wall motion was performed on control, peak contrast, post-contrast and 24 hour studies. With each intracoronary injection, there were transient decreases in blood pressure (p = 0.05 versus control) and increases in left ventricular end-diastolic pressure (p = 0.04 versus control). These were associated with depression of wall motion in contrast-enhanced regions (p = 0.01 versus control) and ST-T segment changes on the electrocardiogram. No significant change in heart rate or left ventricular dP/dt was noted. All variables normalized with the clearance of the contrast effect and remained normal to 24 hours. Light microscopic examination revealed no myocardial or cerebral changes attributable to the contrast agent injections.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
137
|
Ascah KJ, Stewart WJ, Jiang L, Guerrero JL, Newell JB, Gillam LD, Weyman AE. A Doppler-two-dimensional echocardiographic method for quantitation of mitral regurgitation. Circulation 1985; 72:377-83. [PMID: 3891135 DOI: 10.1161/01.cir.72.2.377] [Citation(s) in RCA: 59] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A noninvasive method to accurately quantitate the severity of mitral insufficiency would be of major clinical value. In theory, in the absence of confounding variables, regurgitant mitral flow should represent the difference between forward mitral blood flow and aortic blood flow. Since Doppler-two-dimensional echocardiographic (D2DE) methods for measuring transvalvular mitral and aortic flow have been validated, it should be possible to use mitral and aortic flows derived by this method to calculate regurgitant mitral flow. To assess the validity and accuracy of this combined approach for quantitation of regurgitant flow, we developed an open-chest canine preparation in which we could simulate, vary, and accurately measure degrees of mitral regurgitation. Seven animals were anesthetized and prepared to allow controlled right heart output. Mitral regurgitation was than simulated by placing a flexible conduit incorporating a one-way valve and electromagnetic flowmeter between the left ventricular apex and left atrium. Flow through the tube (effective mitral regurgitation) was varied between 0.2 and 1.8 liters/min and forward cardiac output ranged between 0.5 and 4 liters/min. Transmitral and transaortic flows were calculated by previously reported Doppler methods. Doppler-derived estimates of forward flow through the aortic valve correlated well with the flow measured by flowmeter (r = .92), and regurgitant flow and regurgitant fraction calculated by the D2DE approach also compared well with those measured by flowmeter (r = .84 and .83, respectively). This study demonstrates that mitral regurgitant flow and regurgitant fraction calculated by the D2DE method provide an acceptable measure of both absolute regurgitant flow and the regurgitant fraction in the experimental setting.
Collapse
|
138
|
Gold HK, Fallon JT, Yasuda T, Leinbach RC, Khaw BA, Newell JB, Guerrero JL, Vislosky FM, Hoyng CF, Grossbard E. Coronary thrombolysis with recombinant human tissue-type plasminogen activator. Circulation 1984; 70:700-7. [PMID: 6541103 DOI: 10.1161/01.cir.70.4.700] [Citation(s) in RCA: 85] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The thrombolytic potency and myocardial infarct--sparing potential of recombinant tissue-type plasminogen activator (rt-PA) were studied in electrocardiographically monitored, open-chest, anesthetized dogs. Localized coronary thrombosis was produced in the left anterior descending artery by endothelial injury and instillation of thrombin and fresh blood. After 2 hr of stable thrombotic occlusion, rt-PA was infused intravenously. At a dose of 4.3 micrograms/kg/min, time to reperfusion was greater than 40 min (n = 3). However, at higher infusion rates a linear, dose-dependent time to coronary reperfusion was obtained (r = .88): at 10 micrograms/kg/min reperfusion occurred after 31 +/- 2 min (n = 3), at 15 micrograms/kg/min it was at 26 +/- 7 min (n = 4), and at 25 micrograms/kg/min, lysis was accomplished within 13 +/- 3 min (n = 3). Thrombolysis was not associated with alterations in either plasma hemostatic factors (fibrinogen, plasminogen, and alpha 2-antiplasmin) or in systemic blood pressures. Epicardial electrographic measurements revealed a significant reduction in ST elevation in all reperfused hearts. A randomized, blinded study was also carried out with 15 micrograms/kg/min of rt-PA saline in 18 dogs with 30 min of coronary thrombosis. Reperfusion in the treated group occurred after 28 +/- 3 min. No evidence of thrombolysis was noted in the saline-treated group within 240 min. Size of myocardial infarction was determined by triphenyl tetrazolium chloride staining and planimetry. Infarction involved 2.5 +/- 0.5% of the left ventricular wall in the group receiving rt-PA, but 16 +/- 3% of the left ventricle in the saline-treated group (p = .001). It is concluded that intravenous infusion of rt-PA results in rapid, dose-dependent coronary thrombolysis without systemic fibrinolytic activation and that early lysis of coronary thrombi is associated with substantial salvage of myocardial tissue.
Collapse
|
139
|
O'Gara PT, Guerrero JL, Feldman B, Fallon JT, Block PC. Effect of dextran and aspirin on platelet adherence after transluminal angioplasty of normal canine coronary arteries. Am J Cardiol 1984; 53:1695-8. [PMID: 6203397 DOI: 10.1016/0002-9149(84)90604-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The effect of low-molecular-weight dextran and aspirin on platelet deposition after transluminal coronary angioplasty was studied in a normal canine model. Eighteen anesthetized, open-chest dogs were separated into 4 groups. All dogs received 3,000 units of intravenous heparin 10 to 20 minutes before the procedure. Dogs in Group 1 served as controls and were given no further treatment. Dogs in Group 2 received low-molecular-weight dextran by continuous intravenous infusion at a rate of 20 ml/hour for 1 hour before balloon inflation. Dogs in Group 3 were given 500 ml of low-molecular-weight dextran as an intravenous bolus over 1 hour, beginning 4 hours before the procedure. Dogs in Group 4 were fed 20 mg/kg of aspirin 3 hours before angioplasty. The dogs were killed 10 minutes after angioplasty and the arterial segments subjected to balloon inflation submitted for electron microscopic analysis. An additional group of 10 dogs was used to assess the bleeding times and platelet counts from control and drug-treated dogs. Drug treatment was associated with significant prolongation of the bleeding time and reduction in platelet number. Extensive endothelial desquamation in the area of balloon angioplasty was observed in all dogs. However, no appreciable qualitative difference in either the degree or extent of rapid platelet deposition to the exposed subendothelium was discernible between the control and any of the treatment groups. These results do not confirm previous observations with low-molecular-weight dextran. Further work on the initial and long-term platelet response after endothelial injury should be undertaken in a primate atherosclerotic model.
Collapse
|
140
|
Solares R, Villegas F, Guerrero JL, Olivares A, Herrera G. [Biomechanics of the fibula. Preliminary report]. LA PRENSA MEDICA MEXICANA 1974; 39:453-60. [PMID: 4457866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|