51
|
Rzucidlo J, Jaspan V, Shah B, Paone D, Pushkar I, Kapitman A, Ibrahim H, Hisamoto K, Neuburger P, Saric M, Staniloae C, Vainrib A, Bamira D, Jilaihawi H, Querijero M, Williams M. LONG TERM MORTALITY AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT IN PATINTS WITH CHRONIC KIDNEY DISEASE NOT ON HEMODIALYSIS. J Am Coll Cardiol 2020. [DOI: 10.1016/s0735-1097(20)32064-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
52
|
Williams DM, Nampi RG, Saric M, Grossi EA, Sherrid MV, Swistel DG. On-pump intracardiac echocardiography during septal myectomy for hypertrophic cardiomyopathy. JTCVS Tech 2020; 2:60-66. [PMID: 34317753 PMCID: PMC8298854 DOI: 10.1016/j.xjtc.2020.01.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 12/03/2019] [Accepted: 01/03/2020] [Indexed: 11/02/2022] Open
|
53
|
Shah B, Villablanca PA, Vemulapalli S, Manandhar P, Amoroso NS, Saric M, Staniloae C, Williams MR. Outcomes After Transcatheter Mitral Valve Repair in Patients With Renal Disease. Circ Cardiovasc Interv 2020; 12:e007552. [PMID: 30704286 DOI: 10.1161/circinterventions.118.007552] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Renal disease is associated with poor prognosis despite guideline-directed cardiovascular therapy, and outcomes by sex in this population remain uncertain. METHODS AND RESULTS Patients (n=5213) who underwent a MitraClip procedure in the National Cardiovascular Data Registry Transcatheter Valve Therapy registry were evaluated for the primary composite outcome of all-cause mortality, stroke, and new requirement for dialysis by creatinine clearance (CrCl). Centers for Medicare and Medicaid Services-linked data were available in 63% of patients (n=3300). CrCl was <60 mL/min in 77% (n=4010) and <30 mL/min in 23% (n=1183) of the cohort. Rates of primary outcome were higher with lower CrCl (>60 mL/min, 1.4%; 30-<60 mL/min, 2.7%; <30 mL/min, 5.2%; dialysis, 7.8%; P<0.001), and all low CrCl groups were independently associated with the primary outcome (30-<60 mL/min: adjusted odds ratio, 2.32; 95% CI, 1.38-3.91; <30 mL/min: adjusted odds ratio, 4.44; 95% CI, 2.63-7.49; dialysis: adjusted hazards ratio, 4.52; 95% CI, 2.08-9.82) when compared with CrCl >60 mL/min. Rates of 1-year mortality were higher with lower CrCl (>60 mL/min, 13.2%; 30-<60 mL/min, 18.8%; <30 mL/min, 29.9%; dialysis, 32.3%; P<0.001), and all low CrCl groups were independently associated with 1-year mortality (30-<60 mL/min: adjusted hazards ratio, 1.50; 95% CI, 1.13-1.99; <30 mL/min: adjusted hazards ratio, 2.38; 95% CI, 1.78-3.20; adjusted hazards ratio: dialysis, 2.44; 95% CI, 1.66-3.57) when compared with CrCl >60 mL/min. CONCLUSIONS The majority of patients who undergo MitraClip have renal disease. Preprocedural renal disease is associated with poor outcomes, particularly in stage 4 or 5 renal disease where 1-year mortality is observed in nearly one-third. Studies to determine how to further optimize outcomes in this population are warranted.
Collapse
|
54
|
McLeod JM, Fowler SJ, Cerrone M, Aizer A, Chinitz LA, Raad R, Saric M. Multimodality Imaging of Danon Disease in a Patient with a Novel LAMP2 Mutation. CASE (PHILADELPHIA, PA.) 2019; 3:235-238. [PMID: 31709377 PMCID: PMC6833129 DOI: 10.1016/j.case.2019.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
•Danon disease is a rare X-linked genetic disorder of the LAMP2 gene. •Danon cardiomyopathy has a high incidence of preexcitation and severe LVH. •LAMP2 mutation–associated cardiomyopathy can mimic sarcomeric HCM. •Multimodality imaging is key to a successful diagnosis of Danon disease.
Collapse
|
55
|
Jilaihawi H, Zhao Z, Du R, Staniloae C, Saric M, Neuburger PJ, Querijero M, Vainrib A, Hisamoto K, Ibrahim H, Collins T, Clark E, Pushkar I, Bamira D, Benenstein R, Tariq A, Williams M. Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2019; 12:1796-1807. [DOI: 10.1016/j.jcin.2019.05.056] [Citation(s) in RCA: 113] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/06/2019] [Accepted: 05/21/2019] [Indexed: 10/26/2022]
|
56
|
Vainrib AF, Bamira D, Aizer A, Chinitz LA, Loulmet D, Benenstein RJ, Saric M. Photorealistic imaging of left atrial appendage occlusion/exclusion. Echocardiography 2019; 36:1601-1604. [PMID: 31385344 DOI: 10.1111/echo.14438] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 06/27/2019] [Accepted: 06/30/2019] [Indexed: 11/30/2022] Open
Abstract
Recent improvements in 3D TEE post processing rendering techniques referred to as TrueVue (Philips Medical Systems, Andover, MA, USA). It allows for novel photorealistic imaging of cardiac structures including left atrial appendage (LAA) and its closure devices. Here we present TrueVue images of the LAA prior to and after LAA exclusion/occlusion using various percutaneous and surgical techniques. TrueVue may improve delineation of LAA anatomy prior to occlusion as well as visualization of occluder device position within the LAA.
Collapse
|
57
|
Rodés-Cabau J, Williams MR, Wijeysundera HC, Kereiakes DJ, Paradis JM, Staniloae C, Saric M, Radhakrishnan S, Wilson RF, Kubo SH. Transcatheter Aortic Valve Replacement With the HLT Meridian Valve. Circ Cardiovasc Interv 2019; 12:e008053. [DOI: 10.1161/circinterventions.119.008053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background:
While most self-expanding transcatheter valves are repositionable, only one fully retrievable valve is currently available. The Meridian valve is a new self-expanding valve with full retrievability properties. The objective of our study was to evaluate the early feasibility, preliminary safety, and efficacy of transcatheter aortic valve replacement with the HLT Meridian valve (HLT, Inc).
Methods:
This was a multicenter early feasibility study including patients with severe aortic stenosis at high surgical risk undergoing transfemoral transcatheter aortic valve replacement with the 25-mm Meridian valve. All serious adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiography data were assessed by an independent echocardiography core laboratory.
Results:
A total of 25 patients (mean age, 85±6 years; 80% of men) were included. The valve was successfully implanted in 22 (88%) patients (annulus too large and extreme horizontal aorta in 2 and 1 unsuccessful cases, respectively). Valve retrieval because of an initial nonadequate positioning was attempted and successfully performed in 10 (40%) patients. Echocardiography post-transcatheter aortic valve replacement showed a low mean residual gradient (10±4 mm Hg) and the absence of moderate-severe aortic regurgitation (none-trace and mild aortic regurgitation in 76% and 24% of patients, respectively). Mortality at 30 days was 8%, with no cases of disabling stroke, valve embolization, or major/life-threatening bleeding complications. At 6-month follow-up, the cumulative mortality rate was 12%, with no changes in echocardiographic parameters and no cases of valve dysfunction. The majority of patients (89%) were in New York Heart Association class I-II at 6 months.
Conclusions:
Transcatheter aortic valve replacement with the Meridian valve was feasible and associated with acceptable early and 6-month clinical results. Valve retrieval after full valve deployment was successfully performed in all attempted cases, and valve performance was excellent, with low residual gradients, no cases of moderate-severe aortic regurgitation, and none-trace residual aortic regurgitation in the majority of patients.
Clinical Trial Registration:
URL:
https://www.clinicaltrials.gov
. Unique identifier: NCT02838680 (RADIANT-Canada); NCT02799823 (RADIANT-US).
Collapse
|
58
|
Ahluwalia M, Sehgal S, Vainrib AF, Applebaum R, Latson L, Williams MR, Saric M. Klippel-Feil syndrome: A very unusual cause of severe aortic regurgitation visualized by multimodality imaging. Echocardiography 2019; 36:1586-1589. [PMID: 31246314 DOI: 10.1111/echo.14417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 05/30/2019] [Accepted: 06/02/2019] [Indexed: 10/26/2022] Open
Abstract
A 51-year-old man with Klippel-Feil syndrome (KFS) and immunodeficiency syndrome, status postintravenous immunoglobulin therapy, presented with shortness of breath. He was found to have severe aortic regurgitation in the setting of a trileaflet aortic valve with thickened leaflets and mild prolapse of the right coronary cusp with left ventricular dilation and borderline left ventricular ejection fraction. Although various cardiac anomalies have been described in KPS, otherwise unexplained severe aortic regurgitation has not been previously reported to the best of our knowledge. The patient underwent an uncomplicated surgical aortic valve replacement with a 25-mm Medtronic Avalus pericardial tissue valve resulting in symptomatic improvement. Intra-operative management and transesophageal echocardiography can be particularly challenging in KFS patients. We describe the first reported case of severe aortic regurgitation in KPS, review the cardiac anomalies associated with the syndrome, and highlight the clinical challenges in intra-operative management of these patients.
Collapse
|
59
|
Altszuler D, Vainrib AF, Bamira DG, Benenstein RJ, Aizer A, Chinitz LA, Saric M. Left Atrial Occlusion Device Implantation: the Role of the Echocardiographer. Curr Cardiol Rep 2019; 21:66. [PMID: 31183616 DOI: 10.1007/s11886-019-1151-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE OF REVIEW Atrial fibrillation is the most common arrhythmia worldwide and is a major risk factor for embolic stroke. For patients with atrial fibrillation who are unable to tolerate systemic anticoagulation, left atrial appendage (LAA) occlusion has been shown to mitigate stroke risk. In this article, we describe the vital role of the echocardiographer in intraprocedural guidance of percutaneous LAA occlusion procedures as well as in the pre- and post-procedure assessment of these patients. RECENT FINDINGS A few percutaneously delivered devices for LAA exclusion from the systemic circulation are available in contemporary practice. These devices employ an either exclusive endocardial LAA occlusion approach, such as the Watchman (Boston Scientific, Maple Grove, MN) and Amulet (St. Jude Medical, Minneapolis, MN), or both an endocardial and pericardial (epicardial) approach such as the Lariat procedure (SentreHEART, Palo Alto, CA). Two- and three-dimension transesophageal echocardiography is critical for patient selection, procedure planning, procedural guidance, and ensuring satisfactory immediate as well as long-term LAA occlusion/exclusion efficacy. This review will provide an overview of the role of the echocardiographer in all aspects of LAA occlusion/exclusion procedures for the most commonly used commercially available devices in current practice.
Collapse
|
60
|
|
61
|
Stachel M, Halpern D, Saric M. MANAGEMENT OF DYNAMIC SUBPULMONIC LEFT VENTRICULAR OUTFLOW TRACT OBSTRUCTION IN A PATIENT WITH DEXTRO-TRANSPOSITION OF THE GREAT ARTERIES FOLLOWING ATRIAL SWITCH REPAIR. J Am Coll Cardiol 2019. [DOI: 10.1016/s0735-1097(19)32900-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
62
|
Shah T, Razzouk L, Saric M, Skolnick A, Loulmet D, Halpern D. PERSISTENT ALCAPA PHYSIOLOGY AFTER ALCAPA REPAIR. J Am Coll Cardiol 2019. [DOI: 10.1016/s0735-1097(19)33475-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
63
|
|
64
|
Liu Q, Vainrib AF, Aizer A, Dodson JA, Reynolds HR, Cerfolio RJ, Saric M. Multimodality Imaging of a Rare Case of Bronchogenic Cyst Presenting as New-Onset Atrial Fibrillation in a Young Woman. ACTA ACUST UNITED AC 2018; 2:254-257. [PMID: 30582085 PMCID: PMC6302153 DOI: 10.1016/j.case.2018.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Bronchogenic cyst is a rare cause of new-onset atrial fibrillation. Cysts are often discovered incidentally on diagnostic imaging. Multimodality imaging is critical for effectively diagnosing bronchogenic cysts.
Collapse
|
65
|
Vainrib AF, Bamira D, Benenstein RJ, Aizer A, Chinitz LA, Saric M. Echocardiographic Guidance of the Novel WaveCrest Left Atrial Appendage Occlusion Device. ACTA ACUST UNITED AC 2018; 2:297-300. [PMID: 30582095 PMCID: PMC6302034 DOI: 10.1016/j.case.2018.07.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
The WaveCrest device is a novel LAA occluder with unique features. Two-dimensional and 3D TEE and fluoroscopy are essential for successful implantation. Air between layers of WaveCrest ePTFE fabric may obscure visualization on TEE.
Collapse
|
66
|
Sherrid MV, Riedy K, Rosenzweig B, Ahluwalia M, Arabadjian M, Saric M, Balaram S, Swistel DG, Reynolds HR, Kim B. Hypertrophic cardiomyopathy with dynamic obstruction and high left ventricular outflow gradients associated with paradoxical apical ballooning. Echocardiography 2018; 36:47-60. [PMID: 30548699 DOI: 10.1111/echo.14212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 10/11/2018] [Accepted: 10/13/2018] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Acute left ventricular (LV) apical ballooning with normal coronary angiography occurs rarely in obstructive hypertrophic cardiomyopathy (OHCM); it may be associated with severe hemodynamic instability. METHODS, RESULTS We searched for acute LV ballooning with apical hypokinesia/akinesia in databases of two HCM treatment programs. Diagnosis of OHCM was made by conventional criteria of LV hypertrophy in the absence of a clinical cause for hypertrophy and mitral-septal contact. Among 1519 patients, we observed acute LV ballooning in 13 (0.9%), associated with dynamic left ventricular outflow tract (LVOT) obstruction and high gradients, 92 ± 37 mm Hg, 10 female (77%), age 64 ± 7 years, LVEF 31.6 ± 10%. Septal hypertrophy was mild compared to that of the rest of our HCM cohort, 15 vs 20 mm (P < 0.00001). An elongated anterior mitral leaflet or anteriorly displaced papillary muscles occurred in 77%. Course was complicated by cardiogenic shock and heart failure in 5, and refractory heart failure in 1. High-dose beta-blockade was the mainstay of therapy. Three patients required urgent surgical relief of LVOT obstruction, 2 for refractory cardiogenic shock, and one for refractory heart failure. In the three patients, surgery immediately normalized refractory severe LV dysfunction, and immediately reversed cardiogenic shock and heart failure. All have normal LV systolic function at 45-month follow-up, and all have survived. CONCLUSIONS Acute LV apical ballooning, associated with high dynamic LVOT gradients, may punctuate the course of obstructive HCM. The syndrome is important to recognize on echocardiography because it may be associated with profound reversible LV decompensation.
Collapse
|
67
|
Garshick MS, Mulliken J, Schoenfeld M, Riedy K, Guo Y, Zhong J, Dodson JA, Saric M, Skolnick AH. Average e' velocity on transthoracic echocardiogram is a novel predictor of left atrial appendage sludge or thrombus in patients with atrial fibrillation. Echocardiography 2018; 35:1939-1946. [PMID: 30315597 PMCID: PMC10723071 DOI: 10.1111/echo.14148] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Revised: 08/21/2018] [Accepted: 09/09/2018] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Studies have demonstrated the value of transthoracic echocardiogram (TTE) diastolic parameters in predicting left atrial appendage (LAA) thrombus; however, these studies have been small. We aim to clarify the relationship between TTE diastolic parameters, in particular average e', and LAA thrombus or sludge. METHODS A case-control review was conducted of subjects with non-valvular atrial fibrillation (n = 2263) who had undergone TEE (transesophageal echocardiogram) and had a TTE within 1 year of TEE. Cases of LAA sludge or thrombus were matched to controls by age, sex, left ventricular ejection fraction (LVEF), and anticoagulation status. RESULTS Forty-three subjects (mean age 73 ± 12, 65% male, LVEF 47%, 44% on anticoagulation) with LAA sludge or thrombus were identified. Compared to matched controls, average TTE e' (7.3 ± 2.1 cm/s vs 8.7 ± 2.1 cm/s, P < 0.001) and the E:e' ratio (15 ± 7 cm/s vs 12 ± 5 cm/s; P = 0.005) were significant predictors of LAA sludge or thrombus. Average TTE e' value of >11 cm/s had 100% sensitivity for ruling out LAA sludge or thrombus. CONCLUSION In individuals with atrial fibrillation, average e' >11 cm/s on TTE is a promising independent predictor of the absence of LAA sludge or thrombus on TEE.
Collapse
|
68
|
Quien MM, Vainrib AF, Freedberg RS, Bamira DG, Benenstein RJ, Williams MR, Saric M. Advanced Imaging Techniques for Mitral Regurgitation. Prog Cardiovasc Dis 2018; 61:390-396. [PMID: 30321560 DOI: 10.1016/j.pcad.2018.10.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 10/10/2018] [Indexed: 11/16/2022]
Abstract
Mitral regurgitation (MR) is one of the most commonly encountered valvular lesions in clinical practice. MR can be either primary (degenerative) or secondary (functional) depending on the etiology of MR and the pathology of the mitral valve (MV). Echocardiography is the primary diagnostic tool for MR and is key in determining this etiology as well as MR severity. While clinicians usually turn to 2 Dimensional echocardiography as first-line imaging, 3 Dimensional echocardiography (3DE) has continually shown to be superior in terms of describing MV anatomy and pathology. This review article elaborates on 3DE techniques, modalities, and advances in software. Furthermore, the article demonstrates how 3DE has reformed MR evaluation and has played a vital role in determining patient management.
Collapse
|
69
|
Shah B, McDonald D, Paone D, Redel-Traub G, Jangda U, Guo Y, Saric M, Donnino R, Staniloae C, Robin T, Benenstein R, Vainrib A, Williams MR. Outcomes after transcatheter aortic valve replacement in patients with low versus high gradient severe aortic stenosis in the setting of preserved left ventricular ejection fraction. J Interv Cardiol 2018; 31:849-860. [PMID: 30203608 DOI: 10.1111/joic.12561] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 08/17/2018] [Accepted: 08/20/2018] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) for low gradient (LG) severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) remains an area of clinical uncertainty. METHODS Retrospective review identified 422 patients who underwent TAVR between September 4, 2014 and July 1, 2016. Procedural indication other than severe AS (n = 22) or LVEF <50% (n = 98) were excluded. Outcomes were defined by valve academic research consortium two criteria when applicable and compared between LG (peak velocity <4.0 m/s and mean gradient <40 mmHg; n = 73) and high gradient (HG) (n = 229) groups. The LG group was further categorized as low stroke volume index (SVI) (n = 41) or normal SVI (n = 32). Median follow-up was 747 days [interquartile range 220-1013]. RESULTS Baseline thirty-day mortality risk (LG 6.2% [3.8-8.1] vs HG 5.7% [4.1-7.4], P = 0.43) did not differ between groups. Short-term outcomes, including procedural success rate (86.1% vs 88.8%, P = 0.53), peri-procedural complications (intra-procedural heart block: 6.8% vs 7.9%, P = 0.99; permanent pacemaker placement: 11.0% vs 13.6%, P = 0.69; moderate paravalvular regurgitation: 2.7% vs 1.3%, P = 0.60), and all-cause in-hospital mortality (2.7% vs 0.9%, P = 0.25) did not differ between LG and HG groups. On long-term follow-up, all-cause mortality also did not differ between LG and HG groups (6.8% vs 10.0%, plog-rank = 0.33) or between the LG low SVI (9.8%), LG normal SVI (3.1%), and HG (10.0%) groups (plog-rank = 0.39). CONCLUSION Patients with preserved LVEF undergoing TAVR for severe AS with LG, including LG with low SVI, have no significant difference in adverse outcomes when compared to patients with HG.
Collapse
|
70
|
Du R, Jilaihawi H, Staniloae C, Vapheas E, Zhao ZG, Wang M, Saric M, Neuburger P, Querijero M, Vainrib A, Hisamoto K, Amoroso N, Collins T, Clark E, Pushkar I, Robin T, Sin D, Shah B, Taylor Z, Lee H, Bamira D, Vidal S, Benenstein R, Williams M. TCT-497 Predictors of Post-Dilatation after Self-Expanding Transcatheter Aortic Valve Replacement: Large Single Center Experience. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.2167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
71
|
Zhao ZG, Williams M, Staniloae C, Vapheas E, Du R, Wang M, Saric M, Neuburger P, Querijero M, Vainrib A, Hisamoto K, Amoroso N, Collins T, Clark E, Pushkar I, Sin D, Shah B, Taylor Z, Lee H, Vidal S, Robin T, Bamira D, Benenstein R, Jilaihawi H. TCT-121 A Highly Predictive Model for New Permanent Pacemaker Implantation after Transcatheter Aortic Valve Replacement with Contemporary Self-Expanding Valves: Importance of the Membranous Septum Length. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
72
|
Zhao ZG, Jilaihawi H, Staniloae C, Vapheas E, Du R, Wang M, Saric M, Neuburger P, Querijero M, Vainrib A, Hisamoto K, Amoroso N, Collins T, Clark E, Pushkar I, Robin T, Sin D, Shah B, Taylor Z, Lee H, Vidal S, Bamira D, Benenstein R, Williams M. TCT-494 Influence of High Device Positioning on Outcomes after Transcatheter Aortic Valve Replacement with Contemporary Self-Expanding Valves. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
73
|
Vidal S, Williams M, Lee H, Staniloae C, Vapheas E, Zhao ZG, Du R, Wang M, Saric M, Neuburger P, Querijero M, Vainrib A, Hisamoto K, Amoroso N, Collins T, Clark E, Pushkar I, Robin T, Sin D, Taylor Z, Shah B, Bamira D, Benenstein R, Jilaihawi H. TCT-172 Aortic Valvar Complex and Cardiac Anatomy: Gender-Related Differences in Patients Undergoing Transcatheter Aortic Valve Replacement. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
74
|
Ngai C, Freedberg RS, Latson L, Argilla M, Benenstein RJ, Vainrib AF, Donnino R, Saric M. Multimodality imaging of scimitar syndrome in adults: A report of four cases. Echocardiography 2018; 35:1684-1691. [DOI: 10.1111/echo.14124] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 07/24/2018] [Accepted: 07/26/2018] [Indexed: 12/01/2022] Open
|
75
|
Quien MM, Saric M. Ultrasound imaging artifacts: How to recognize them and how to avoid them. Echocardiography 2018; 35:1388-1401. [PMID: 30079966 DOI: 10.1111/echo.14116] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Accepted: 07/10/2018] [Indexed: 12/13/2022] Open
Abstract
Echocardiography has become a critical tool in clinical cardiology in evaluating cardiac physiology and diagnosing cardiac disease states. However, imaging artifacts are commonly encountered and often lead to misdiagnoses of life-threatening diseases, such as aortic dissection and ventricular thrombus. It is, thus, critical for clinicians to understand these artifacts to avoid these misdiagnoses and protect patients from undue intervention. Artifacts can be broken down into two categories: those from violation of ultrasound system assumptions and those from interference by external equipment and devices. This review article discusses the most commonly encountered artifacts by category, explains their physical mechanisms, elaborates on their most common presentations, and instructs clinicians on how to avoid their misinterpretation.
Collapse
|