101
|
Rani M, Shim WJ, Han GM, Jang M, Song YK, Hong SH. Hexabromocyclododecane in polystyrene based consumer products: an evidence of unregulated use. CHEMOSPHERE 2014; 110:111-119. [PMID: 24630246 DOI: 10.1016/j.chemosphere.2014.02.022] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 01/09/2014] [Accepted: 02/02/2014] [Indexed: 06/03/2023]
Abstract
Polystyrene (PS) is made flame retardant by combining with hexabromocyclododecane (HBCD). HBCD can release from consumer products during their production, use or disposal. As a result, it has become a ubiquitous contaminant in the environment with a high potential for bioaccumulation. Therefore, to evaluate the extent of exposure to HBCD from PS, we determined the concentration of HBCD in a variety of products (n=34) made from three types of commonly used PS: expanded PS (EPS), extruded PS foam (XPS), and extruded PS. The concentration of HBCD was highest in EPS, with a mean value and range of 475643±16710ngg(-1) and 106-960000ngg(-1), respectively. PS related to building construction and laboratory uses had a significantly higher concentration of HBCD (3300-905000ngg(-1)), except XPS styroboard (191±100ngg(-1)). Lower concentrations were measured in most food-related products (24.3-199ngg(-1)). However, a relatively high concentration of HBCD was detected in an ice box (960000±29000ngg(-1)), aquaculture buoy (53500±2100ngg(-1)), and disposable tray (8430±730ngg(-1)) used in fish market, raising concern for public health. Our data demonstrate a wide variation in the concentration of HBCD, suggesting a lack of proper controls for the addition of HBCD to PS products. Other brominated flame retardants (BFRs) were also detected in a majority of the XPS products (TBBPA=3.83-545ngg(-1), BTBPE=44-216ngg(-1) and DBDPE=215-4200ngg(-1)). Thus, HBCD is being added to PS along with other BFRs that cannot be ignored.
Collapse
|
102
|
Dmitrienko SG, Kochuk EV, Apyari VV, Tolmacheva VV, Zolotov YA. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review. Anal Chim Acta 2014; 850:6-25. [PMID: 25441155 DOI: 10.1016/j.aca.2014.08.023] [Citation(s) in RCA: 161] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Revised: 08/07/2014] [Accepted: 08/11/2014] [Indexed: 01/12/2023]
Abstract
Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed.
Collapse
|
103
|
Kankaanpää A, Ariniemi K, Heinonen M, Kuoppasalmi K, Gunnar T. Use of illicit stimulant drugs in Finland: a wastewater study in ten major cities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 487:696-702. [PMID: 24331163 DOI: 10.1016/j.scitotenv.2013.11.095] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 11/15/2013] [Accepted: 11/17/2013] [Indexed: 05/15/2023]
Abstract
Estimations of drug use at the national level are generally based on various sources of information, such as drug seizures, socio-scientific studies, toxicological data and hospital records. Nevertheless, all of these approaches have limitations that cannot be overcome, even if conclusions are drawn from combined data retrieved from different sources. Drug epidemiology through wastewater analysis has the potential to provide unique perspectives, internationally comparable data, and up-to-date information on the use of both traditional illicit drugs and new psychoactive substances (NPSs). In Finland, no large-scale studies on regional illicit drug consumption, based on a wastewater approach, have been reported. In this study, 24-h influent composite samples were collected during two 1-week study periods from ten different wastewater treatment plants in May and November-December 2012. The cities included in the study represent the geographical areas throughout Finland and cover 40% of the Finnish population. The samples were analyzed with an in-house validated, ultra high-performance liquid-chromatography mass spectrometric (UHPLC-MS/MS) method for various common illicit drugs and some NPS type stimulant drugs. The results were also compared with available statistics, information on drug seizures and laboratory-confirmed toxicological data, as well as other studies available based on wastewater analysis. The data show that illicit stimulant drug use is more common in the larger cities of Southern Finland. Amphetamine was the most commonly used drug in all 10 cities during both collection periods (excluding the collection period in May in Lappeenranta). Cocaine consumption remains very low in Finland in comparison to other European countries; it was concentrated in the biggest cities in Southern Finland. This study shows interesting temporal and spatial differences in drug use in Finland, as well as the possibilities of using wastewater analytics to reveal local hotspots of NPS consumption.
Collapse
|
104
|
Xu F, Yang T, Fang D, Xu Q, Chen Y. An investigation of heat shock protein 27 and P-glycoprotein mediated multi-drug resistance in breast cancer using liquid chromatography-tandem mass spectrometry-based targeted proteomics. J Proteomics 2014; 108:188-97. [PMID: 24882106 DOI: 10.1016/j.jprot.2014.05.016] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2014] [Revised: 05/13/2014] [Accepted: 05/21/2014] [Indexed: 12/20/2022]
Abstract
UNLABELLED One missing puzzle piece to study heat shock protein 27 (HSP27) in P-glycoprotein (P-gp) mediated multi-drug resistance (MDR) was the amount of HSP27 and the extent of its phosphorylation in the biological context. Liquid chromatography-tandem mass spectrometry (LC/MS/MS)-based targeted proteomics allows researchers to monitor associated proteins and their modification simultaneously and quantitatively. In this study, a targeted proteomics assay was first developed and validated for the quantification of HSP27 and its phosphorylated forms. Using this assay, the level of HSP27 was determined in non-tumoral cells MCF-10A, parental drug-sensitive cancer cells MCF-7/WT and drug-resistant cancer cells MCF-7/ADR. A decrease of HSP27 expression was observed in P-gp overexpressed MCF-7/ADR cells. A quantitative time-course analysis of both HSP27 and P-gp in doxorubicin (DOX)-treated MCF-7/WT cells also implied that HSP27 may participate in the P-gp modulation. Furthermore, stoichiometry of site-specific HSP27 phosphorylation indicated that DOX treatment rapidly induced the HSP27 phosphorylation at Ser82. Moreover, conventional analytical methods were also performed for a comparison. BIOLOGICAL SIGNIFICANCE LC/MS/MS-based targeted proteomics turns out to be a promising quantification approach for the study of proteins in the preclinical and clinical environment. Unfortunately, rare studies applied this technology to detect multiple associated proteins or protein modification in one experiment. This study demonstrated the potential of LC/MS/MS-based targeted proteomics to understand the cell events in a more accurate context of biological system. By the quantitative time-course analysis of HSP27 and its phosphorylated forms at sites of Ser15 and Ser82, the possible role of HSP27 in P-gp mediated MDR was suggested. Further development of targeted proteomics in future may provide more insight into signal transduction pathways upon perturbation of a protein network or changes to a panel of proposed biomarkers in a given disease state.
Collapse
|
105
|
Mao Y, Wang J, Zhao Y, Yan R, Li H, Chen CS, Lee RJ, Byrd JC, Lee LJ, Muthusamy N, Phelps MA. Quantification of OSU-2S, a novel derivative of FTY720, in mouse plasma by liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2014; 98:160-5. [PMID: 24927402 DOI: 10.1016/j.jpba.2014.05.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Revised: 05/01/2014] [Accepted: 05/06/2014] [Indexed: 02/03/2023]
Abstract
OSU-2S is a novel anti-cancer and immune modulatory agent designed specifically to avert the immunosuppressive effects and related toxicities observed in clinical studies with its predecessor analog, FTY720. To characterize its preclinical pharmacokinetics, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of OSU-2S in mouse plasma. Ethyl acetate extraction of samples containing OSU-2S and the internal standard, Sph-17, was followed by separation with a 6min gradient (water/0.1% formic acid and methanol/0.1% formic acid) on a reverse-phase C18 column at room temperature. Selected reaction monitoring was used for detection on a triple quadrupole mass spectrometer with positive ionization. The assay was linear over the concentration range 3-3000ng/mL with accuracy ranging from 103 to 111%, and both within- and between-run precision (CV%) ≤11%. All stability samples were within ±15% of nominal values, and replicates were within 15% CV. The assay was successfully applied to a mouse pharmacokinetic study of OSU-2S with intravenous and intraperitoneal administration. OSU-2S non-compartmental pharmacokinetic parameters, area under the concentration-time curve, clearance, and elimination half-life were estimated at 1522hμg/L, 3.06L/h/kg and 15.6h, respectively, for intravenous injection. Systemic availability after intraperitoneal injection was approximately 46%. These data demonstrate the OSU-2S compound displays acceptable pharmacokinetic properties for further in vivo pharmacologic evaluation, which can be facilitated by the validated LC-MS/MS assay.
Collapse
|
106
|
Cai MQ, Wei XQ, Du CH, Ma XM, Jin MC. Novel amphiphilic polymeric ionic liquid-solid phase micro-extraction membrane for the preconcentration of aniline as degradation product of azo dye Orange G under sonication by liquid chromatography-tandem mass spectrometry. J Chromatogr A 2014; 1349:24-9. [PMID: 24857038 DOI: 10.1016/j.chroma.2014.05.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 04/24/2014] [Accepted: 05/02/2014] [Indexed: 10/25/2022]
Abstract
A novel amphiphilic polymeric ionic liquid membrane containing a hydrophilic bromide anion and a hydrophobic carbonyl group was synthesized in dimethylformamide (DMF) systems using the ionic liquid 1-butyl-3-vinylimidazolium bromide (BVImBr) and the methylmethacrylate (MMA) as monomers. The prepared amphiphilic ploy-methylmethacrylate-1-butyl-3-vinylimidazolium bromide (MMA-BVImBr) was characterized by a scanning electron microscope and an infrared spectrum instrument. The results of solid-phase micro-extraction membrane (SPMM) experiments showed that the adsorption capacity of membrane was about 0.76μgμg(-1) for aniline. Based on this, a sensitive method for the determination of trace aniline, as a degradation product of azo dye Orange G under sonication, was developed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The calibration curve showed a good linearity ranging from 0.5 to 10.0μgL(-1) with a correlation coefficient value of 0.9998. The limit of quantification was 0.5μgL(-1). The recoveries ranged from 90.6% to 96.1%. The intra- and inter-day relative standard deviations were less than 8.3% and 10.9%. The developed SPMM-LC-MS/MS method was used successfully for preconcentration of trace aniline produced during the sonication of Orange G solution.
Collapse
|
107
|
Yong S, Chen Y, Lee TK, Lee HK. Determination of total thyroxine in human serum by hollow fiber liquid-phase microextraction and liquid chromatography-tandem mass spectrometry. Talanta 2014; 126:163-9. [PMID: 24881548 DOI: 10.1016/j.talanta.2014.03.058] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Revised: 03/24/2014] [Accepted: 03/25/2014] [Indexed: 12/19/2022]
Abstract
Determination of total thyroxine in human serum using hollow fiber liquid-phase microextraction (HF-LPME) has been accomplished for the first time. HF-LPME serves as an inexpensive sample pretreatment and the cleanup method that is nearly solvent-free. Thyroxine was extracted through a water immiscible organic solvent immobilized in the wall pores of a polypropylene hollow fiber into 20μl of an aqueous acceptor phase inside the lumen of the hollow fiber. This technique produced extracts that had comparable cleanness with those obtained using solid-phase extraction (SPE). Serum samples with endogenous thyroxine were spiked with isotopically-labeled thyroxine and analyzed by liquid chromatography-tandem mass spectrometry after HF-LPME extraction. Extraction parameters including the organic phase, acid/base concentration of acceptor phase, stirring speed and extraction time were optimized. The calibration range was found to be linear over 1-1000ng/g with the limit of detection (LOD) of 0.3 ng/g. For quantification of total thyroxine in human serum, 6 subsamples were prepared and the results indicated very good precision with a relative standard deviation of <1.3%. The difference from the SPE method was less than 1.2%, with independent t-test showing insignificant bias. Two reference materials of human serum were analyzed, and our obtained values were compared with the reference values. The results showed very good precision with RSD around 0.2% and the deviation from the reference values were -3.1% and -2.1%. The newly developed method is precise, accurate, inexpensive, and environmentally friendly.
Collapse
|
108
|
Bähre H, Kaever V. Measurement of 2',3'-cyclic nucleotides by liquid chromatography-tandem mass spectrometry in cells. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 964:208-11. [PMID: 24656940 DOI: 10.1016/j.jchromb.2014.02.046] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Revised: 02/26/2014] [Accepted: 02/28/2014] [Indexed: 02/01/2023]
Abstract
Recently, the occurrence of 2',3'-cyclic nucleoside monophosphates (2',3'-cNMPs) in addition to 3',5'-cNMPs in mammalian tissues was reported. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of four 2',3'-cyclic nucleotides, i.e., 2',3'-cAMP, 2',3'-cCMP, 2',3'-cGMP, 2',3'-cUMP, in cell samples. Chromatographic separation was achieved using a Zorbax eclipse XCB-C18 (50 mm×4.6 mm; 1.8 μm column; Agilent) connected to a QTRAP5500 system (AB Sciex) operating in positive ionization mode. Calibration curves were constructed in the range 0.41 fmol/μL to 1666.6 fmol/μL for 2',3'-cAMP, 2',3'-cCMP, and 2',3'-cGMP, and 3.3-1666.6 fmol/μL for 2',3'-cUMP, respectively, showing squared correlation coefficients >0.9992. Accuracy and inter- and intra-day precision lay within the required ranges of <20% for LLOQ and <15% for higher concentration levels. The method was applied to the analysis of nucleotides in two different cell lines (Hek293T and HuT-78).
Collapse
|
109
|
Tu X, Lu Y, Zhong D, Zhang Y, Chen X. A sensitive LC-MS/MS method for quantifying clofarabine triphosphate concentrations in human peripheral blood mononuclear cells. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 964:202-7. [PMID: 24529342 DOI: 10.1016/j.jchromb.2014.01.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2013] [Revised: 12/19/2013] [Accepted: 01/12/2014] [Indexed: 11/16/2022]
Abstract
Clofarabine triphosphate is an intracellular active metabolite of clofarabine. In the present study, we developed and validated a rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) for quantifying clofarabine triphosphate concentrations in human peripheral blood mononuclear cells (PBMCs). PBMCs were isolated from blood using the Ficoll gradient centrifugation method. Chromatographic separation was performed on a CN column using an isocratic mobile phase comprising acetonitrile/5mM ammonium acetate with 0.001% ammonium hydroxide (20/80, v/v) at a flow rate of 0.60 mL/min. Detection was carried out by MS/MS in the multiple reaction monitoring mode using a negative electrospray ionization interface. The method was validated in concentration ranges of 1.25-100 ng/10(7) cells with acceptable accuracy and precision using 50 μL of cell extract. Clofarabine triphosphate was stable in a series of stability studies with bench-top, auto-sampler, and repeated freeze-thaw cycles. The validated method was successfully used to measure the concentrations of clofarabine triphosphate in PBMCs from cancer patients treated with clofarabine.
Collapse
|
110
|
Wang D, Zhou X, Wang L, Wang S, Sun XL. Quantification of free sialic acid in human plasma through a robust quinoxalinone derivatization and LC-MS/MS using isotope-labeled standard calibration. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 944:75-81. [PMID: 24291723 DOI: 10.1016/j.jchromb.2013.11.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 11/03/2013] [Accepted: 11/07/2013] [Indexed: 10/26/2022]
Abstract
We report an accurate quantification of free sialic acid (SA) in human plasma using LC-MS/MS method with isotope-labeled standard calibration (ILSC) and robust derivatization. Specifically, derivatization of SA with a stable and inexpensive 3,4-diaminotoluene (DAT) provides a stable product of SA with high MS response, proving a convenient and cost-effective LC-MS/MS analysis of free SA. In addition, the use of (13)C3-SA as calibration standard ensured the accuracy for the measurement. This assay used ultra high performance liquid chromatography (UHPLC) for separation of native/labeled SA and IS from matrix interference, and employed mass spectrometry in multiple reaction monitoring (MRM) mode for sensitive and selective detection. We have achieved a lower limit of quantification (LLOQ) of 20ng/mL and a total running time of 4.2min, which is the most sensitive and quick measurement for free SA in biomatrices.
Collapse
|
111
|
Carmella SG, Chen M, Zarth A, Hecht SS. High throughput liquid chromatography-tandem mass spectrometry assay for mercapturic acids of acrolein and crotonaldehyde in cigarette smokers' urine. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 935:36-40. [PMID: 23934173 PMCID: PMC3925436 DOI: 10.1016/j.jchromb.2013.07.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2013] [Revised: 07/05/2013] [Accepted: 07/07/2013] [Indexed: 01/07/2023]
Abstract
3-Hydroxypropylmercapturic acid (3-HPMA) and 3-hydroxy-1-methylpropylmercapturic acid (HMPMA) are urinary metabolites of the toxicants acrolein and crotonaldehyde, respectively. Virtually all human urine samples contain these metabolites, resulting from the action of glutathione-S-transferases on acrolein and crotonaldehyde, which are lipid peroxidation products, environmental and dietary contaminants, and constituents of cigarette smoke. We have developed a high throughput liquid chromatography-tandem mass spectrometry method for quantitative analysis of 3-HPMA and HMPMA in large numbers of small urine samples, as would be required in molecular epidemiology and clinical studies relating levels of these metabolites to cancer risk. Solid-phase extraction on mixed mode reverse phase-anion exchange 96-well plates provided sufficient purification for LC-MS/MS analysis, which was performed by auto-injection using a 96-well format, and resulted in clean, readily interpretable chromatograms, with detection limits of 4.5pmol/mL urine for 3-HPMA and 3.5pmol/mL urine for HMPMA. Accuracy was 92% for 3-HPMA and 97% for HMPMA while inter-day precision was 9.1% (coefficient of variation) for 3-HPMA and 11.0% for HMPMA. The method was applied to more than 2600 urine samples from smokers; mean levels of 3-HPMA and HMPMA were 4800±5358 (S.D.)pmol/mL and 3302±3341pmol/mL, respectively.
Collapse
|
112
|
Yang T, Xu F, Xu J, Fang D, Yu Y, Chen Y. Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 936:18-24. [PMID: 23968647 DOI: 10.1016/j.jchromb.2013.07.023] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Revised: 07/05/2013] [Accepted: 07/23/2013] [Indexed: 10/26/2022]
Abstract
P-glycoprotein (P-gp) is the most frequently proposed factor for multi-drug resistance. It is traditionally measured using antibody-based methods. While these techniques can provide relative quantification values for P-gp levels, the important information that is usually missing is its amount in the biological system. In this study, a novel and advanced liquid chromatography-tandem mass spectrometry (LC/MS/MS)-based targeted proteomics assay was developed and validated for the determination of P-gp in the breast cancer drug sensitive cell line MCF-7/WT and the drug resistant cell line MCF-7/ADR. Three tryptic peptides (434STTVQLMQR442, 674GSQAQDR680 and 368IIDNKPSIDSYSK380) can specifically represent P-gp. Among these peptides, 434STTVQLMQR442 was selected as the surrogate analyte for quantification, and a stable isotope-labeled synthetic peptide with the same sequence was used as an internal standard. The calibration range was validated from 10 to 1000ng/mL. The intra- and inter-day precisions were within 5.9% and 3.7%, respectively. The accuracy for the quality control (QC) samples was within 8.0%. Using this assay, the amounts of P-gp were accurately quantified as 3.53fg/cell (∼2.08×10(-2)amol/cell) in the MCF-7/WT cells and 34.5fg/cell (∼2.02×10(-1)amol/cell) in the MCF-7/ADR cells. This outcome was then compared with those obtained by conventional analytical methods including confocal microscopy, western blotting and flow cytometry. The comparative results show that not only is the LC/MS/MS-based targeted proteomics assay able to monitor the protein levels in a more accurate manner, but the large discrepancy observed between the other methods was most likely due to the lack of specificity and the semi-quantitative nature of the conventional assays.
Collapse
|
113
|
Buiarelli F, Gallo V, Di Filippo P, Pomata D, Riccardi C. Development of a method for the analysis of underivatized amino acids by liquid chromatography/tandem mass spectrometry: application on Standard Reference Material 1649a (urban dust). Talanta 2013; 115:966-72. [PMID: 24054689 DOI: 10.1016/j.talanta.2013.07.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Revised: 07/02/2013] [Accepted: 07/04/2013] [Indexed: 10/26/2022]
Abstract
A liquid chromatography-tandem mass spectrometry analytical procedure has been developed for the detection and quantitative determination of underivatized amino acids at low concentrations in a Standard Reference Material-urban dust. In order to minimize interferences of other compounds, an accelerated solvent extraction followed by a solid phase extraction on two different cartridges was applied prior to LC-MS-MS. Fourteen amino acids were separated by high resolution liquid chromatography, detected and quantified by multiple reaction monitoring on a triple quadrupole. The proposed methodology has been applied for the first time on Standard Reference Material 1649a (urban dust) from the National Institute of Standards and Technology, that does not report certification values for these compounds. This methodology avoids the derivatization step and allows the amino acid quantification in a complex matrix, such as that of atmospheric particulate matter, and represent a good method suitable to analyze this class of compounds in atmospheric aerosol. The selected strategy demonstrated to be fit-for-purpose, by applying it to a real atmospheric sample with the aim to verify the efficacy of the study and to provide information about the organic matter content.
Collapse
|
114
|
Zembrzuska J, Matusiewicz H, Polkowska-Motrenko H, Chajduk E. Simultaneous quantitation and identification of organic and inorganic selenium in diet supplements by liquid chromatography with tandem mass spectrometry. Food Chem 2013; 142:178-87. [PMID: 24001829 DOI: 10.1016/j.foodchem.2013.05.004] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Revised: 11/19/2012] [Accepted: 05/02/2013] [Indexed: 10/26/2022]
Abstract
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for selenium speciation in dietary supplements. Chromatographic separation was performed on a TSK-Gel ODS-100V column using a mixture of 5mM ammonium acetate water solution and methanol as a mobile phase. Conditions chosen for this process allowed to separate all investigated chemical compounds of selenium: seleno-l-methionine, methyl-seleno-l-cysteine, l-selenocystine, methaneseleninic acid, selenite and selenate. A tandem mass spectrometer with an ion trap operating in negative or positive ion mode according to the selenium form being determined was used as a detector. Three extraction procedures: water extraction, enzymatic hydrolysis and sequential extraction were used for preparation of samples for the determination of the actual forms of selenium in diet supplements. The developed method was used for analysis of six dietary supplements containing selenium bought in a pharmacy and supermarket. Apart from speciation analysis of selenium content in supplements total selenium content was determined using instrumental neutron activation analysis (INAA). All expected forms of selenium except for selenite were determined using LC-MS/MS technique. It should be stressed that amounts of selenate were smaller than expected.
Collapse
|
115
|
Gajula R, Maddela R, Babu Ravi V, Inamadugu JK, Pilli NR. A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for duloxetine in human plasma: Its pharmacokinetic application. J Pharm Anal 2013; 3:36-44. [PMID: 29403794 PMCID: PMC5760945 DOI: 10.1016/j.jpha.2012.09.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2012] [Accepted: 09/18/2012] [Indexed: 11/08/2022] Open
Abstract
This paper describes a simple, rapid and sensitive liquid chromatography–tandem mass spectrometry assay for the determination of duloxetine in human plasma. A duloxetine stable labeled isotope (duloxetine d5) was used as an internal standard. Analyte and the internal standard were extracted from 100 μL of human plasma via solid phase extraction technique using Oasis HLB cartridges. The chromatographic separation was achieved on a C18 column by using a mixture of acetonitrile–5 mM ammonium acetate buffer (83:17, v/v) as the mobile phase at a flow rate of 0.9 mL/min. The calibration curve obtained was linear (r2≥0.99) over the concentration range of 0.05–101 ng/mL. Multiple-reaction monitoring mode (MRM) was used for quantification of ion transitions at m/z 298.3/154.1 and 303.3/159.1 for the drug and the internal standard, respectively. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The proposed method was found to be applicable to clinical studies.
Collapse
|
116
|
Sagratini G, Fernández-Franzón M, De Berardinis F, Font G, Vittori S, Mañes J. Simultaneous determination of eight underivatised biogenic amines in fish by solid phase extraction and liquid chromatography-tandem mass spectrometry. Food Chem 2011; 132:537-43. [PMID: 26434328 DOI: 10.1016/j.foodchem.2011.10.054] [Citation(s) in RCA: 93] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2010] [Revised: 06/05/2011] [Accepted: 10/17/2011] [Indexed: 10/15/2022]
Abstract
Biogenic amines on fish tissue are formed as a result of bacterial contamination and spoilage during storage. A new method based on liquid chromatography (LC) and tandem mass spectrometry (MS/MS) using a triple quadrupole (QqQ) analyser was developed for the analysis of eight biogenic amines (cadaverine, histamine, phenylethylamine, putrescine, spermine, spermidine, tyramine and tryptamine) in fish tissues. Sample preparation was performed by extraction with trichloroacetic acid 5% and solid phase extraction clean up with STRATA X cartridge. The MS/MS method was validated and compared with a method based on the analysis of dansyl derivatives by LC and fluorescence detector (FD). MS/MS achieved higher sensitivity (from 0.02mgkg(-1) for spermidine and phenylethylamine to 0.2mgkg(-1) for spermine) when compared to FD (from 1mgkg(-1) for putrescine and tyramine to 4mgkg(-1) for histamine); MS/MS method showed higher precision too, with intraday relative standard deviations (RSDs) from 1% to 4% with respect to those obtained with FD method (from 3% to 17%). Recovery study was conducted at two different fortification levels and the average ranged from 71% to 93% for all of the studied compounds with RSDs lower than 18%. Matrix-matched standards were used to counteract matrix effect observed in MS/MS determination. The applicability of the method was demonstrated by the analysis of biogenic amines in fish obtained from commercials of Valencia.
Collapse
|
117
|
Regueiro J, Rossignoli AE, Álvarez G, Blanco J. Automated on-line solid-phase extraction coupled to liquid chromatography-tandem mass spectrometry for determination of lipophilic marine toxins in shellfish. Food Chem 2011; 129:533-540. [PMID: 30634263 DOI: 10.1016/j.foodchem.2011.04.054] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2010] [Revised: 03/12/2011] [Accepted: 04/19/2011] [Indexed: 10/18/2022]
Abstract
Automated on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for fast determination of lipophilic marine toxins in shellfish samples. The direct coupling of an on-line SPE column to LC-MS/MS was accomplished using column switching techniques. Suitable chromatographic separation was performed on a reversed-phase C18 column under alkaline conditions (pH 11). The selected reversed-phase C18 SPE column allowed rapid and efficient on-line desalting of hydrolysed shellfish samples, avoiding signal suppression during mass spectrometry detection. Furthermore, the on-line SPE procedure allowed reducing matrix effects observed in raw and hydrolysed shellfish extracts. The proposed method was evaluated in terms of linearity, precision, accuracy and limits of detection (LODs). Quantitative recovery (97-102%) and satisfactory inter-day precision (RSD<8%) were achieved for all target compounds. LODs in the sub-μgkg-1 level (0.37-0.68μgkg-1) were obtained for all toxins except for okadaic acid, which showed a value of 2.75μgkg-1. Several mussel samples from North-western Spain were finally analysed in order to demonstrate the applicability of the method. Okadaic acid was the predominant toxin in all samples, although other lipophilic toxins were also detected.
Collapse
|