51
|
Stan E, Muresan CO, Dumache R, Ciocan V, Ungureanu S, Mihailescu A, Daescu E, Duda-Seiman C, Menghiu G, Hutanu D, Enache A. From Jane Doe to Sofia: DNA Extraction Protocol from Bones and Teeth without Liquid Nitrogen for Identifying Skeletal Remains. Int J Mol Sci 2024; 25:5114. [PMID: 38791155 PMCID: PMC11120754 DOI: 10.3390/ijms25105114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/04/2024] [Accepted: 05/06/2024] [Indexed: 05/26/2024] Open
Abstract
DNA analysis plays a crucial role in forensic investigations, helping in criminal cases, missing persons inquiries, and archaeological research. This study focuses on the DNA concentration in different skeletal elements to improve human identification efforts. Ten cases of unidentified skeletal remains brought to the Institute of Forensic Medicine in Timisoara, Romania, underwent DNA analysis between 2019 and 2023. The results showed that teeth are the best source for DNA extraction as they contain the highest concentration of genetic material, at 3.68 ng/µL, compared to the petrous temporal bone (0.936 ng/µL) and femur bone (0.633 ng/µL). These findings highlight the significance of teeth in forensic contexts due to their abundant genetic material. Combining anthropological examination with DNA analysis enhances the understanding and precision of identifying human skeletal remains, thus advancing forensic science. Selecting specific skeletal elements, such as the cochlea or teeth, emerges as crucial for reliable genetic analyses, emphasizing the importance of careful consideration in forensic identification procedures. Our study concludes that automated DNA extraction protocols without liquid nitrogen represent a significant advancement in DNA extraction technology, providing a faster, more efficient, and less labor-intensive method for extracting high-quality DNA from damaged bone and tooth samples.
Collapse
|
52
|
Nakagawa T, Doi M, Nishi K, Sugahara T. Cross-species amplification from non-human primate DNAs in commercial human DNA assay kits. Leg Med (Tokyo) 2024; 68:102369. [PMID: 38325235 DOI: 10.1016/j.legalmed.2023.102369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 10/04/2023] [Accepted: 11/23/2023] [Indexed: 02/09/2024]
Abstract
Species specificity of commercial human DNA quantification kits and short tandem repeat (STR) profiling kits was examined using primate DNA samples. These samples comprised 33 individuals from eight primate species, each with gender and kinship data, including human (Homo sapiens), chimpanzee (Pan troglodytes), gorilla (Gorilla gorilla), and orangutan (Pongo pygmaeus) of Hominidae family, and Japanese macaque (Macaca fuscata), long-tailed macaque (Macaca fascicularis), hamadryas baboon (Papio hamadryas), and savannah monkey (Chlorocebus sp.) of Cercopithecidae family. The findings revealed varying levels of cross-species amplifications in all non-human DNA samples that correlated with their evolutionary proximity to humans, both kit types. Moreover, cross-species amplification, including female DNA samples, was observed in a Y-chromosomal STR profiling kit. Additionally, species specificity differed among the commercial kits examined. The cross-species amplification data presented in this study offer valuable assistance in interpreting the results of individual human identification in forensic cases involving non-human primates.
Collapse
|
53
|
Yu J, Jin X, Du W, Bai Y, Zhou X, Gao M, Li S, Qin J, Chen X, Liu Y, Yu J, Chen C, Xie Q, Xie S, Kong X, Zhan W, Yu Y, Li K, Ji Q, Chen F, Chen P. Unveiling facial kinship: The BioKinVis dataset for facial kinship verification and genetic association studies. Electrophoresis 2024; 45:794-804. [PMID: 38161244 DOI: 10.1002/elps.202300169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 12/01/2023] [Accepted: 12/13/2023] [Indexed: 01/03/2024]
Abstract
Facial image-based kinship verification represents a burgeoning frontier within the realms of computer vision and biomedicine. Recent genome-wide association studies have underscored the heritability of human facial morphology, revealing its predictability based on genetic information. These revelations form a robust foundation for advancing facial image-based kinship verification. Despite strides in computer vision, there remains a discernible gap between the biomedical and computer vision domains. Notably, the absence of family photo datasets established through biological paternity testing methods poses a significant challenge. This study addresses this gap by introducing the biological kinship visualization dataset, encompassing 5773 individuals from 2412 families with biologically confirmed kinship. Our analysis delves into the distribution and influencing factors of facial similarity among parent-child pairs, probing the potential association between forensic short tandem repeat polymorphisms and facial similarity. Additionally, we have developed a machine learning model for facial image-based kinship verification, achieving an accuracy of 0.80 in the dataset. To facilitate further exploration, we have established an online tool and database, accessible at http://120.55.161.230:88/.
Collapse
|
54
|
Alwi AR, Mahat NA, Mohd Salleh F, Ishar SM, Kamaluddin MR, A Rashid MR, Syed Hassan SNRK. Genetic diversity and forensic statistical support for the 12 X-STR markers in the Malaysian Indian population using Qiagen Investigator® Argus X-12 QS kit. Leg Med (Tokyo) 2024; 68:102416. [PMID: 38325234 DOI: 10.1016/j.legalmed.2024.102416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 01/14/2024] [Accepted: 01/26/2024] [Indexed: 02/09/2024]
Abstract
X-chromosome short tandem repeats (X-STRs) are useful for human identification, especially in complex kinship scenarios. Since forensic statistical parameters vary among populations and the X-STRs population data for the diverse population of Peninsular Malaysia's are unavailable, this attempt for Indians (n = 201) appears forensically relevant to support the 12 X-STRs markers' evidential value for human identification in Malaysia. The Qiagen Investigator® Argus X-12 QS kit showed that DXS10135 was the most polymorphic locus with high genetic diversity, polymorphism information richness, heterozygosity, and exclusion power. Based on allele frequencies, the strength of discrimination and mean exclusion chance (MECKrüger, MECKishida, MECDesmarais, and MECDesmaraisDuo) values for the Malaysian Indians were ≥0.999997790686228. As for haplotype frequencies, the overall discrimination power and mean exclusion probability (MECKrüger, MECKishida, MECDesmarais, and MECDesmaraisDuo) were ≥0.9999984801951. The genetic distance, neighbor-joining phylogenetic tree, and principal component analysis also supported the evidential value of the 12 X-STRs markers for forensic practical caseworks in Malaysia.
Collapse
|
55
|
So MH, Lee JE, Lee HY. Strategies to deal with genetic analyzer-specific DNA methylation measurements. Electrophoresis 2024; 45:906-915. [PMID: 38488745 DOI: 10.1002/elps.202300185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 02/25/2024] [Accepted: 03/02/2024] [Indexed: 05/23/2024]
Abstract
Targeted bisulfite sequencing using single-base extension (SBE) can be used to measure DNA methylation via capillary electrophoresis on genetic analyzers in forensic labs. Several accurate age prediction models have been reported using this method. However, using different genetic analyzers with different software settings can generate different methylation values, leading to significant errors in age prediction. To address this issue, the study proposes and compares four methods as follows: (1) adjusting methylation values using numerous actual body fluid DNA samples, (2) adjusting methylation values using control DNAs with varying methylation ratios, (3) constructing new age prediction models for each genetic analyzer type, and (4) constructing new age prediction models that could be applied to all types of genetic analyzers. To test the methods for adjusting values using actual body fluid DNA samples, previously reported adjusting equations were used for blood/saliva DNA age prediction markers (ELOVL2, FHL2, KLF14, MIR29B2CHG/C1orf132, and TRIM59). New equations were generated for semen DNA age prediction markers (TTC7B, LOC401324/cg12837463, and LOC729960/NOX4) by drawing polynomial regression lines between the results of the three types of genetic analyzers (3130, 3500, and SeqStudio). The same method was applied to obtain adjustment equations using 11 control DNA samples. To develop new age prediction models for each genetic analyzer type, linear regression analysis was conducted using DNA methylation data from 150 blood, 150 saliva, and 62 semen samples. For the genetic analyzer-independent models, control DNAs were used to formulate equations for calibrating the bias of the data from each genetic analyzer, and linear regression analysis was performed using calibrated body fluid DNA data. In the comparison results, the genetic analyzer-specific models showed the highest accuracy. However, genetic analyzer-independent models through bias adjustment also provided accurate age prediction results, suggesting its use as an alternative in situations with multiple constraints.
Collapse
|
56
|
Ghemrawi M, Fernandez-Tejero N, Vaquero L, Wanna A, Carmel JH, McCord B. An examination of differences in epigenetic methylation of saliva type samples based on collection method. Electrophoresis 2024; 45:897-905. [PMID: 38385810 DOI: 10.1002/elps.202300240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 01/04/2024] [Accepted: 01/08/2024] [Indexed: 02/23/2024]
Abstract
In the context of forensic casework, it is imperative to both establish a DNA profile from biological specimens and accurately identify the specific bodily fluid source. To achieve this, DNA methylation markers have been developed for the differentiation of blood, semen, vaginal epithelial secretions, and saliva samples. Saliva, alternatively referred to as oral fluid, is recognized for its heterogeneous cellular composition, characterized by a mixture of epithelial, leukocytic, and bacterial cells. Consequently, our research has revealed variations in methylation percentages that correlate with the method employed for collecting saliva samples. To investigate these concepts, we scrutinized four CpG markers situated within or in proximity to the BCAS4, SLC12A8, SOX2OT, and FAM43A genes. Subsequently, we designed primers based on bioinformatically transformed reference sequences for these markers and rigorously assessed their quality by examining dimer and hairpin formation, melting temperature, and specificity. These loci were identified as saliva markers based on either buccal swabs or spit collection. Yet, there has been minimal or no research conducted to explore the variations in methylation between different collection methods. For this study, buccal, lip, tongue, spit, and nasal swabs were collected from 20 individuals (N = 100). Mock forensic samples, which include chewing gum (N = 10) and cigarettes (N = 10), were also tested. DNA was extracted, bisulfite converted, then amplified using in-house designed assays, and pyrosequenced. The methylation levels were compared to other body fluids (semen, blood, vaginal epithelia, and menstrual blood [N = 32]). A total of 608 pyrosequencing results demonstrated that sampling location and collection method can greatly influence the level of methylation, highlighting the importance of examining multiple collection/deposition methods for body fluids when developing epigenetic markers.
Collapse
|
57
|
Konrad H, Hartung B, Poetsch M. (Un)Reliable detection of menstrual blood in forensic casework - evaluation of the Seratec® PMB test with mock samples. Int J Legal Med 2024; 138:781-786. [PMID: 38030939 PMCID: PMC11003878 DOI: 10.1007/s00414-023-03138-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 11/20/2023] [Indexed: 12/01/2023]
Abstract
The identification of the type of body fluid in crime scene evidence may be crucial, so that the efforts are high to reduce the complexity of these analyses and to minimize time and costs. Reliable immunochromatographic rapid tests for specific and sensitive identification of blood, saliva, urine and sperm secretions are already routinely used in forensic genetics. The recently introduced Seratec® PMB test is said to detect not only hemoglobin, but also differentiate menstrual blood from other secretions containing blood (cells) by detecting D-dimers. In our experimental set-up, menstrual blood could be reliably detected in mock forensic samples. Here, the result was independent of sample age and extraction buffer volume. It was also successfully demonstrated that all secretions without blood cells were negative for both, hemoglobin (P) and D-dimer (M). However, several blood cell-containing secretions/tissues comprising blood (injury), nasal blood, postmortem blood and wound crust also demonstrated positive results for D-dimer (M) and were therefore false positives. For blood (injury) and nasal blood, this result was reproduced for different extraction buffer volumes. The results of this study clearly demonstrate that the Seratec® PMB test is neither useful nor suitable for use in forensic genetics because of the great risk of false positive results which can lead to false conclusions, especially in sexual offense or violent acts.
Collapse
|
58
|
Bali GK, Cuenca D, Wallin J. Effects and considerations of multiplexing ForenSeq Kintelligence libraries with a negative control. Electrophoresis 2024; 45:852-866. [PMID: 38449358 DOI: 10.1002/elps.202300285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 02/06/2024] [Accepted: 02/21/2024] [Indexed: 03/08/2024]
Abstract
The negative template control or negative amplification control has been an essential component of the forensic DNA analysis workflow that helps monitor contamination. As such, the inclusion of a negative control in forensic DNA analysis has been a requirement for all laboratories audited under the FBI's Quality Assurance Standards. As massively parallel sequencing (MPS) becomes more conventional in forensic laboratories, considerations for the inclusion of a negative control in every sequencing run can be evaluated. Although the inclusion of a negative control in library preparation and the first sequencing run has a practical function, there is less utility for its inclusion in all subsequent sequencing runs for that library preparation. Although this is universal to all MPS assays, it is most relevant for an assay that has a low sample multiplexing capacity, such as the ForenSeq Kintelligence Kit (Qiagen/Verogen, Inc.). The ForenSeq Kintelligence Kit is an investigative genetic genealogy (IGG) sequencing-based assay that targets 10,230 forensically relevant single-nucleotide polymorphisms. The manufacturer recommends multiplexing 3 libraries per sequencing run, which includes controls. The purpose of this study was to investigate the effect of the inclusion of a negative control in every Kintelligence sequencing run. We observed that the library generated from a negative amplification control will take 7%-14% of the run output. The loss of sequencing space taken by a negative control decreased the available output for DNA-containing samples, leading in some cases to allele or locus dropout and accompanying higher numbers of sixth to seventh order unknown associations in GEDmatch PRO.
Collapse
|
59
|
Chiao A, Ge J. Determining lineages between individuals with high-density mitochondrial and Y-chromosomal single-nucleotide polymorphisms. Electrophoresis 2024; 45:843-851. [PMID: 38010138 DOI: 10.1002/elps.202300142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 10/19/2023] [Accepted: 11/12/2023] [Indexed: 11/29/2023]
Abstract
Genetic genealogy has been more frequently used in forensic investigations in identifying criminals. However, the current genetic genealogy applications usually do not consider lineage markers (including both Y and mitochondrial deoxyribonucleic acid (DNA)), which is probably because not all distant relatives share the same lineage markers. In addition, there is no study to show how to use lineage markers and what methods or thresholds should be applied in genetic genealogy. In this study, we developed a method to quickly determine if two single-nucleotide polymorphism (SNP) profiles are from the same paternal or material lineages by using a mismatch frequency of the SNPs in Y-chromosomal or mitochondrial DNA. For both Y and mitochondrial SNPs, profile pairs from the same or different lineages can be decided with high accuracies (i.e., 0.380% or 0.157% error rates with Y and mitochondrial DNA, respectively). With kinship coefficient filtering based on autosomal SNPs, the accuracies of determining maternal and paternal lineage can be further improved (i.e., 0.120% or 0.057% error rates with Y and mitochondrial DNA, respectively, using a threshold of kinship coefficient >0). This study shows that lineage markers can be very powerful tools with high accuracies to determine lineages, which could help solve cases and reduce costs for genetic genealogy investigations.
Collapse
|
60
|
Luo Y, Zhang J, Ni M, Mei Z, Ye Q, Guo B, Fang L, Feng D, Wang L, Yan J, Wang G. Pilot validation of on-field STR typing and human identity testing by MinION nanopore sequencing. Electrophoresis 2024; 45:885-896. [PMID: 38356010 DOI: 10.1002/elps.202300234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/19/2024] [Accepted: 01/24/2024] [Indexed: 02/16/2024]
Abstract
Nanopore sequencing technology has broad application prospects in forensic medicine due to its small size, portability, fast speed, real-time result analysis capabilities, single-molecule sequencing abilities, and simple operation. Here, we demonstrate for the first time that nanopore sequencing platforms can be used to identify individuals in the field. Through scientific and reasonable design, a nanopore MinION MK1B device and other auxiliary devices are integrated into a portable detection box conducive to individual identification at the accident site. Individual identification of 12 samples could be completed within approximately 24 h by jointly detecting 23 short tandem repeat (STR) loci. Through double-blinded experiments, the genotypes of 49 samples were successfully determined, and the accuracy of the STR genotyping was verified by the gold standard. Specifically, the typing success rate for 1150 genotypes was 95.3%, and the accuracy rate was 86.87%. Although this study focused primarily on demonstrating the feasibility of full-process testing, it can be optimistically predicted that further improvements in bioinformatics workflows and nanopore sequencing technology will help enhance the feasibility of Oxford Nanopore Technologies equipment for real-time individual identification at accident sites.
Collapse
|
61
|
Bonsu DNO, Higgins D, Simon C, Henry JM, Austin JJ. Metal-DNA interactions: Exploring the impact of metal ions on key stages of forensic DNA analysis. Electrophoresis 2024; 45:779-793. [PMID: 37638716 DOI: 10.1002/elps.202300070] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 06/15/2023] [Accepted: 08/18/2023] [Indexed: 08/29/2023]
Abstract
Forensic DNA analysis continues to be hampered by the complex interactions between metals and DNA. Metal ions may cause direct DNA damage, inhibit DNA extraction and polymerase chain reaction (PCR) amplification or both. This study evaluated the impact of metal ions on DNA extraction, quantitation, and short tandem repeat profiling using cell-free and cellular (saliva) DNA. Of the 11 metals assessed, brass exhibited the strongest PCR inhibitory effects, for both custom and Quantifiler Trio quantitation assays. Metal ion inhibition varied across the two quantitative PCR assays and the amount of DNA template used. The Quantifiler Trio internal PCR control (IPC) only revealed evidence of PCR inhibition at higher metal ion concentrations, limiting the applicability of IPC as an indicator of the presence of metal inhibitor in a sample. Notably, ferrous ions were found to significantly decrease the extraction efficiency of the DNA-IQ DNA extraction system. The amount of DNA degradation and inhibition in saliva samples caused by metal ions increased with a dilution of the sample, suggesting that the saliva matrix provides protection from metal ion effects.
Collapse
|
62
|
Han J, Zhuang B, Zou L, Wang D, Jiang L, Wei YL, Zhao L, Zhao L, Li C. A developmental validation of the Quick TargSeq 1.0 integrated system for automated DNA genotyping in forensic science for reference samples. Electrophoresis 2024; 45:814-828. [PMID: 38459798 DOI: 10.1002/elps.202300187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 03/10/2024]
Abstract
Analysis of short tandem repeats (STRs) is a global standard method for human identification. Insertion/Deletion polymorphisms (DIPs) can be used for biogeographical ancestry inference. Current DNA typing involves a trained forensic worker operating several specialized instruments in a controlled laboratory environment, which takes 6-8 h. We developed the Quick TargSeq 1.0 integrated system (hereinafter abbreviated to Quick TargSeq) for automated generation of STR and DIP profiles from buccal swab samples and blood stains. The system fully integrates the processes of DNA extraction, polymerase chain reaction (PCR) amplification, and electrophoresis separation using microfluidic biochip technology. Internal validation studies were performed using RTyper 21 or DIP 38 chip cartridges with single-source reference samples according to the Scientific Working Group for DNA Analysis Methods guidelines. These results indicated that the Quick TargSeq system can process reference samples and generate STR or DIP profiles in approximately 2 h, and the profiles were concordant with those determined using traditional STR or DIP analysis methods. Thus, reproducible and concordant DNA profiles were obtained from reference samples. Throughout the study, no lane-to-lane or run-to-run contamination was observed. The Quick TargSeq system produced full profiles from buccal swabs with at least eight swipes, dried blood spot cards with two 2-mm disks, or 10 ng of purified DNA. Potential PCR inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect the amplification reactions of the instrument. The overall success rate and concordance rate of 153 samples were 94.12% and 93.44%, respectively, which is comparable to other commercially available rapid DNA instruments. A blind test initiated by a DNA expert group showed that the system can correctly produce DNA profiles with 97.29% genotype concordance with standard bench-processing methods, and the profiles can be uploaded into the national DNA database. These results demonstrated that the Quick TargSeq system can rapidly generate reliable DNA profiles in an automated manner and has the potential for use in the field and forensic laboratories.
Collapse
|
63
|
Li Z, Liu N, Yuan F, Guan Z, Liu J, Liu F, Ren J, Yan J, Zhang G. Development of a novel panel for blood identification based on blood-specific CpG-linked SNP markers. Int J Legal Med 2024; 138:1205-1219. [PMID: 37853302 DOI: 10.1007/s00414-023-03105-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 09/27/2023] [Indexed: 10/20/2023]
Abstract
Blood-containing mixtures often appear in murder and robbery cases, and their identification plays a significant role in solving crimes. In recent years, the co-detection of DNA methylation markers (CpG) and single nucleotide polymorphism (SNP) markers has been shown to be a promising tool for the identification of semen and its donor. However, similar research on blood stains that are frequently found at crime scenes has not yet been reported. In this study, we employed blood-specific CpG-linked SNP markers (CpG-SNP) for blood-specific genotyping and the linking of blood and its donor. The tissue-specific CpG markers were screened from the literature and further verified by combining bisulfite conversion with amplification-refractory mutation system (ARMS) technology. Meanwhile, adjacent SNP markers with a minor allele frequency (MAF) greater than 0.1 were selected within 400 bp upstream and downstream of the CpG markers. SNP genotyping was performed using SNaPshot technology on a capillary electrophoresis (CE) platform. Finally, a multiplex panel, including 19 blood-specific CpG linked to 23 SNP markers, as well as 1 semen-specific CpG, 1 vaginal secretion-specific CpG, and 1 saliva-specific CpG marker, was constructed successfully. The panel showed good tissue specificity and blood stains stored at room temperature for up to nine months and moderately degraded (4 < DI < 10) could be effectively identified. Moreover, it could also be detected when blood content in the mixed stains was as low as 1%. In addition, 15 ng of DNA used for bisulfite conversion was required for obtaining a complete profile. The cumulative discrimination power of the panel among the Han population of northern China could reach 0.999983. This is the first investigation conducted for the simultaneous identification of blood and its donor regardless of other body fluids included in mixed stains. The successful construction of the panel will play a vital role in the comprehensive analysis of blood-containing mixtures in forensic practice.
Collapse
|
64
|
C Zapico S, Matos S, Conte J. Assessment of the efficiency of DNA isolation and profiling applying a temperature-driven method in human remains. Electrophoresis 2024; 45:805-813. [PMID: 38247192 DOI: 10.1002/elps.202300273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/02/2024] [Accepted: 01/10/2024] [Indexed: 01/23/2024]
Abstract
The identification of human remains is of utmost importance in a variety of scenarios. One of the primary identification methods is DNA. DNA extraction from human remains could be difficult, particularly in situations where the remains have been exposed to environmental conditions and other insults. Several studies tried to improve extraction by applying different approaches. ForensicGEM Universal (MicroGem) is a single-tube approach to DNA extraction and a temperature-driven method that could have some advantages with respect to previous techniques, among them, reducing the risk of contamination, not requiring specialized equipment, or several steps to perform. The aim of this study was to assess, for the first time, the efficiency of DNA extraction and quality of STR profiles applying the MicroGem protocol and modifications of this protocol from tooth samples in comparison with automatic extraction (AE). Our results indicated that AE and MicroGem performed similar, though with variability depending on the MicroGem modifications, increasing the DNA yield and STR profile quality when DNA is concentrated with Microcon. These findings demonstrated the efficiency of this methodology for DNA extraction from human remains while also providing a simple and quick technique suitable to apply in a variety of forensic scenarios.
Collapse
|
65
|
Filoglu G, Sımsek SZ, Ersoy G, Can K, Bulbul O. Epigenetic-based age prediction in blood samples: Model development. J Forensic Sci 2024; 69:869-879. [PMID: 38308398 DOI: 10.1111/1556-4029.15478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 01/19/2024] [Accepted: 01/22/2024] [Indexed: 02/04/2024]
Abstract
Aging is a complex process influenced by genetic, epigenetic, and environmental factors that lead to tissue deterioration and frailty. Epigenetic mechanisms, such as DNA methylation, play a significant role in gene expression regulation and aging. This study presents a new age estimation model developed for the Turkish population using blood samples. Eight CpG sites in loci TOM1L1, ELOVL2, ASPA, FHL2, C1orf132, CCDC102B, cg07082267, and RASSF5 were selected based on their correlation with age. Methylation patterns of these sites were analyzed in blood samples from 100 volunteers, grouped into age categories (20-35, 36-55, and ≥56). Sensitivity analysis indicated a reliable performance with DNA inputs ≥1 ng. Statistical modeling, utilizing Multiple Linear Regression, underscores the reliability of the primary 6-CpG model, excluding cg07082267 and TOM1L1. This model demonstrates strong correlations with chronological age (r = 0.941) and explains 88% of the age variance with low error rates (MAE = 4.07, RMSE = 5.73 years). Validation procedures, including a training-test split and fivefold cross-validation, consistently confirm the model's accuracy and consistency. The study indicates minimal variation in error scores across age cohorts and no significant gender differences. The developed model showed strong predictive accuracy, with the ability to estimate age within certain prediction intervals. This study contributes to the age prediction by using DNA methylation patterns, which can have disparate applications, including forensic and clinical assessments.
Collapse
|
66
|
Liu Y, Liu T, Chen R, Hao S, Li S, Tang Z, Xia M, Li X, Cheng C, Li Q, Li H. Developmental validation of a novel 8-dye fluorescent typing system with 59 Y-STRs and 3 Y-indels for forensic applications. Electrophoresis 2024; 45:829-842. [PMID: 38010597 DOI: 10.1002/elps.202300046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 06/30/2023] [Accepted: 11/06/2023] [Indexed: 11/29/2023]
Abstract
An 8-dye fluorescence-labeling forensic Y-chromosomal short tandem repeats (Y-STRs) kit, the 62-plex Y-STR multiplex amplification system, was developed and optimized. The system was validated by testing PCR conditions, stutter ratios (SR) and peak height ratios, sensitivity, mixture samples, precision and accuracy, species-specificity, and inhibition studies according to the Scientific Working Group on DNA Analysis Methods guidelines. PCR-based studies showed that the recommended PCR conditions were optimized for this kit. In the sensitivity study, a full profile was obtained from template DNA with a quantity of u125 pg. Consistent profiles were obtained from three different laboratories. The SRs in all loci were less than 15%, and nice balance and suitable average peak height were shown. No peaks were detected in the profiles of common animal species and microorganisms. In the male-male mixture studies, all loci were observed at a ratio of 1:8, and in the male-female mixture study, all alleles could be profiled at a ratio of 1:500 if the male DNA inputs were ≥0.5 ng/µL. An inhibitor study demonstrated that the kit had varying degrees of resistance to the presence of common inhibitors. Population study demonstrated the 62-plex Y-STR Kit improved the power of discrimination in unrelated Chinese Han males (n = 192). When haplotype diversity was 1, the probability of discrimination power of the 62-plex Y-STR Kit was 0.9948, which is suitable for forensic investigations. The results show that the developed 8-dye fluorescence labeling 62 loci system is sensitive, robust, convenient, and highly informative for forensic applications.
Collapse
|
67
|
Otagiri T, Sato N, Shiozaki T, Harayama Y, Matsumoto M, Kobayashi K, Asamura H. An optimal skeletal element for DNA testing: Evaluation of DNA quantity and quality from various bone types in routine forensic practice. Leg Med (Tokyo) 2024; 68:102415. [PMID: 38280273 DOI: 10.1016/j.legalmed.2024.102415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 12/19/2023] [Accepted: 01/18/2024] [Indexed: 01/29/2024]
Abstract
For human identification, the quality and quantity of DNA must be sufficient for amplification and analysis. When DNA extraction from bone tissues and teeth is required, the optimal skeletal elements should be selected as samples for DNA extraction because DNA yield differs among elements. Recently, some studies have reported that a high quantity of high-quality DNA can be extracted from the small cancellous bones of the hands and feet. In this study, we evaluated the effectiveness of small cancellous bones in the human identification of skeletal remains in routine forensic genetic casework. Cancellous bones [phalanges, (meta)carpal bones, and (meta)tarsal bones)] and the cortical bones (femur and petrous bones) and teeth, which have generally been recommended as samples, were collected from the same individuals that needed identifying using DNA analysis in our laboratory. The quantity of DNA from small cancellous bones tended to be higher than that from cortical bones, and the quality from the former was as high as that from the latter. This study showed that in routine forensic casework, the small cancellous bones of the hands and feet should be actively selected as samples for DNA testing.
Collapse
|
68
|
Fan Q, Li L, Yang H, Xu D, Wang Y, Jin B, Du B. Development and validation of a new multiplex panel using SNaPshot-based DIP-TriSNP markers for forensic DNA mixtures. Electrophoresis 2024; 45:867-876. [PMID: 38651903 DOI: 10.1002/elps.202300215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 01/28/2024] [Accepted: 03/10/2024] [Indexed: 04/25/2024]
Abstract
Short tandem repeat analysis is challenging when dealing with unbalanced mixtures in forensic cases due to the presence of stutter peaks and large amplicons. In this research, we propose a novel genetic marker called DIP-TriSNP, which combines deletion/insertion polymorphism (DIP) with tri-allelic single nucleotide polymorphism in less than 230 bp length of human genome. Based on multiplex PCR and SNaPShot, a panel, including 14 autosomal DIP-TriSNPs and one Y chromosomal DIP-SNP, had been developed and applied to genotyping 102 unrelated Han Chinese individuals in Sichuan of China and simulated a mixture study. The panel sensitivity can reach as low as 0.1 ng DNA template, and the minor contributor of DNA can be detected with the highest ratio of 19:1, as indicated by the obtained results. In the Sichuan Han population, the cumulative probability of informative genotypes reached 0.997092, with a combined power of discrimination of 0.999999998801. The panel was estimated to detect more than two alleles in at least one locus in 99.69% of mixtures of the Sichuan Han population. In conclusion, DIP-TriSNPs have shown promising as an innovative DNA marker for identifying the minor contributor in unbalanced DNA mixtures, offering advantages such as short amplifications, increased polymorphism, and heightened sensitivity.
Collapse
|
69
|
Wang X, Muenzler M, King J, Liu M, Li H, Budowle B, Ge J. A complete pipeline enables haplotyping and phasing macrohaplotype in long sequencing reads for polyploidy samples and a multi-source DNA mixture. Electrophoresis 2024; 45:877-884. [PMID: 38196015 DOI: 10.1002/elps.202300143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 11/19/2023] [Accepted: 11/30/2023] [Indexed: 01/11/2024]
Abstract
Macrohaplotype combines multiple types of phased DNA variants, increasing forensic discrimination power. High-quality long-sequencing reads, for example, PacBio HiFi reads, provide data to detect macrohaplotypes in multiploidy and DNA mixtures. However, the bioinformatics tools for detecting macrohaplotypes are lacking. In this study, we developed a bioinformatics software, MacroHapCaller, in which targeted loci (i.e., short TRs [STRs], single nucleotide polymorphisms, and insertion and deletions) are genotyped and combined with novel algorithms to call macrohaplotypes from long reads. MacroHapCaller uses physical phasing (i.e., read-backed phasing) to identify macrohaplotypes, and thus it can detect multi-allelic macrohaplotypes for a given sample. MacroHapCaller was validated with data generated from our designed targeted PacBio HiFi sequencing pipeline, which sequenced ∼8-kb amplicon regions harboring 20 core forensic STR loci in human benchmark samples HG002 and HG003. MacroHapCaller also was validated in whole-genome long-read sequencing data. Robust and accurate genotyping and phased macrohaplotypes were obtained with MacroHapCaller compared with the known ground truth. MacroHapCaller achieved a higher or consistent genotyping accuracy and faster speed than existing tools HipSTR and DeepVar. MacroHapCaller enables efficient macrohaplotype analysis from high-throughput sequencing data and supports applications using discriminating macrohaplotypes.
Collapse
|
70
|
Castagnola MJ, Medina-Paz F, Zapico SC. Uncovering Forensic Evidence: A Path to Age Estimation through DNA Methylation. Int J Mol Sci 2024; 25:4917. [PMID: 38732129 PMCID: PMC11084977 DOI: 10.3390/ijms25094917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 04/27/2024] [Accepted: 04/28/2024] [Indexed: 05/13/2024] Open
Abstract
Age estimation is a critical aspect of reconstructing a biological profile in forensic sciences. Diverse biochemical processes have been studied in their correlation with age, and the results have driven DNA methylation to the forefront as a promising biomarker. DNA methylation, an epigenetic modification, has been extensively studied in recent years for developing age estimation models in criminalistics and forensic anthropology. Epigenetic clocks, which analyze DNA sites undergoing hypermethylation or hypomethylation as individuals age, have paved the way for improved prediction models. A wide range of biomarkers and methods for DNA methylation analysis have been proposed, achieving different accuracies across samples and cell types. This review extensively explores literature from the past 5 years, showing scientific efforts toward the ultimate goal: applying age prediction models to assist in human identification.
Collapse
|
71
|
Salvo NM, Olsen GH, Berg T, Janssen K. Biogeographical Ancestry Analyses Using the ForenSeq TM DNA Signature Prep Kit and Multiple Prediction Tools. Genes (Basel) 2024; 15:510. [PMID: 38674444 PMCID: PMC11050699 DOI: 10.3390/genes15040510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 04/15/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
The inference of biogeographical ancestry (BGA) can assist in police investigations of serious crime cases and help to identify missing people and victims of mass disasters. In this study, we evaluated the typing performance of 56 ancestry-informative SNPs in 177 samples using the ForenSeq™ DNA Signature Prep Kit on the MiSeq FGx system. Furthermore, we compared the prediction accuracy of the tools Universal Analysis Software v1.2 (UAS), the FROG-kb, and GenoGeographer when inferring the ancestry of 503 Europeans, 22 non-Europeans, and 5 individuals with co-ancestry. The kit was highly sensitive with complete aiSNP profiles in samples with as low as 250pg input DNA. However, in line with others, we observed low read depth and occasional drop-out in some SNPs. Therefore, we suggest not using less than the recommended 1ng of input DNA. FROG-kb and GenoGeographer accurately predicted both Europeans (99.6% and 91.8% correct, respectively) and non-Europeans (95.4% and 90.9% correct, respectively). The UAS was highly accurate when predicting Europeans (96.0% correct) but performed poorer when predicting non-Europeans (40.9% correct). None of the tools were able to correctly predict individuals with co-ancestry. Our study demonstrates that the use of multiple prediction tools will increase the prediction accuracy of BGA inference in forensic casework.
Collapse
|
72
|
Cai M, Lei F, Liu Y, Wang X, Wang H, Xie W, Yang Z, Yang S, Zhu B. Joint application of A-InDels and miniSTRs for forensic personal, full and half sibling identifications, and genetic differentiation analyses in two populations from China. BMC Genomics 2024; 25:329. [PMID: 38566035 PMCID: PMC10986087 DOI: 10.1186/s12864-024-10187-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 03/04/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND Previously, a novel multiplex system of 64 loci was constructed based on capillary electrophoresis platform, including 59 autosomal insertion/deletions (A-InDels), two Y-chromosome InDels, two mini short tandem repeats (miniSTRs), and an Amelogenin gene. The aim of this study is to evaluate the efficiencies of this multiplex system for individual identification, paternity testing and biogeographic ancestry inference in Chinese Hezhou Han (CHH) and Hubei Tujia (CTH) groups, providing valuable insights for forensic anthropology and population genetics research. RESULTS The cumulative values of power of discrimination (CDP) and probability of exclusion (CPE) for the 59 A-InDels and two miniSTRs were 0.99999999999999999999999999754, 0.99999905; and 0.99999999999999999999999999998, 0.99999898 in CTH and CHH groups, respectively. When the likelihood ratio thresholds were set to 1 or 10, more than 95% of the full sibling pairs could be identified from unrelated individual pairs, and the false positive rates were less than 1.2% in both CTH and CHH groups. Biogeographic ancestry inference models based on 35 populations were constructed with three algorithms: random forest, adaptive boosting and extreme gradient boosting, and then 10-fold cross-validation analyses were applied to test these three models with the average accuracies of 86.59%, 84.22% and 87.80%, respectively. In addition, we also investigated the genetic relationships between the two studied groups with 33 reference populations using population statistical methods of FST, DA, phylogenetic tree, PCA, STRUCTURE and TreeMix analyses. The present results showed that compared to other continental populations, the CTH and CHH groups had closer genetic affinities to East Asian populations. CONCLUSIONS This novel multiplex system has high CDP and CPE in CTH and CHH groups, which can be used as a powerful tool for individual identification and paternity testing. According to various genetic analysis methods, the genetic structures of CTH and CHH groups are relatively similar to the reference East Asian populations.
Collapse
|
73
|
Kanthaswamy S. Review: Wildlife forensic genetics-Biological evidence, DNA markers, analytical approaches, and challenges. Anim Genet 2024; 55:177-192. [PMID: 38123142 DOI: 10.1111/age.13390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 12/02/2023] [Accepted: 12/03/2023] [Indexed: 12/23/2023]
Abstract
Wildlife-related crimes are the second most prevalent lawbreaking offense globally. This illicit trade encompasses hunting, breeding and trafficking. Besides diminishing many species and their habitats and ecosystems, hindering the economic development of local communities that depend on them, undermining the rule of law and financing terrorism, various cross-species transmissions (zoonoses) of pathogens, including COVID-19, can be attributed to wildlife crimes. Wildlife forensics applies interdisciplinary scientific analyses to support law enforcement in investigating wildlife crimes. Its main objectives are to identify the taxonomic species in question, determine if a crime has been committed, link a suspect to the crime and support the conviction and prosecution of the perpetrator. This article reviews wildlife crime and its implications, wildlife forensic science investigation, common forms of wildlife biological evidence, including DNA, wildlife DNA techniques and challenges in wildlife forensic genetics. The article also reviews the contributions of genetic markers such as short tandem repeat (STR) and mitochondrial DNA (mtDNA) markers, which provide the probative genetic data representing the bulk of DNA evidence for solving wildlife crime. This review provides an overview of wildlife DNA databases, which are critical for searching and matching forensic DNA profiles and sequences and establishing how frequent forensic DNA profiles and sequences are in a particular population or geographic region. As such, this review will contain an in-depth analysis of the current status of wildlife forensic genetics, and it will be of general interest to wildlife and conservation biologists, law enforcement officers, and academics interested in combating crimes against wildlife using animal forensic DNA methods.
Collapse
|
74
|
McDonald C, Taylor D, Linacre A. PCR in Forensic Science: A Critical Review. Genes (Basel) 2024; 15:438. [PMID: 38674373 PMCID: PMC11049589 DOI: 10.3390/genes15040438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 03/26/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
The polymerase chain reaction (PCR) has played a fundamental role in our understanding of the world, and has applications across a broad range of disciplines. The introduction of PCR into forensic science marked the beginning of a new era of DNA profiling. This era has pushed PCR to its limits and allowed genetic data to be generated from trace DNA. Trace samples contain very small amounts of degraded DNA associated with inhibitory compounds and ions. Despite significant development in the PCR process since it was first introduced, the challenges of profiling inhibited and degraded samples remain. This review examines the evolution of the PCR from its inception in the 1980s, through to its current application in forensic science. The driving factors behind PCR evolution for DNA profiling are discussed along with a critical comparison of cycling conditions used in commercial PCR kits. Newer PCR methods that are currently used in forensic practice and beyond are examined, and possible future directions of PCR for DNA profiling are evaluated.
Collapse
|
75
|
Liu X, Yang C, Chen X, Han X, Liu H, Zhang X, Xu Q, Yang X, Liu C, Chen L, Liu C. A novel 193-plex MPS panel integrating STRs and SNPs highlights the application value of forensic genetics in individual identification and paternity testing. Hum Genet 2024; 143:371-383. [PMID: 38499885 DOI: 10.1007/s00439-024-02658-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 02/13/2024] [Indexed: 03/20/2024]
Abstract
Massively parallel sequencing (MPS) has emerged as a promising technology for targeting multiple genetic loci simultaneously in forensic genetics. Here, a novel 193-plex panel was designed to target 28 A-STRs, 41 Y-STRs, 21 X-STRs, 3 sex-identified loci, and 100 A-SNPs by employing a single-end 400 bp sequencing strategy on the MGISEQ-2000™ platform. In the present study, a series of validations and sequencing of 1642 population samples were performed to evaluate the overall performance of the MPS-based panel and its practicality in forensic application according to the SWGDAM guidelines. In general, the 193-plex markers in our panel showed good performance in terms of species specificity, stability, and repeatability. Compared to commercial kits, this panel achieved 100% concordance for standard gDNA and 99.87% concordance for 14,560 population genotypes. Moreover, this panel detected 100% of the loci from 0.5 ng of DNA template and all unique alleles at a 1:4 DNA mixture ratio (0.2 ng minor contributor), and the applicability of the proposed approach for tracing and degrading DNA was further supported by case samples. In addition, several forensic parameters of STRs and SNPs were calculated in a population study. High CPE and CPD values greater than 0.9999999 were clearly demonstrated and these results could be useful references for the application of this panel in individual identification and paternity testing. Overall, this 193-plex MPS panel has been shown to be a reliable, repeatable, robust, inexpensive, and powerful tool sufficient for forensic practice.
Collapse
|