51
|
Gan HQ, Wang Q, Zhang H, Liu X, Deng HM, Song HP, Wang ZQ, Li QJ. [Effects of RGD peptides-grafted porous tantalum on morphological change of MG63 osteoblasts-tantalum conjunctive interface and expression of osteogenesis factors]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2018; 50:176-182. [PMID: 29483743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To investigate the effects of the Arg-Gly-Asp polypeptedes (RGD) peptides-modified porous tantalum surface on osteoblasts morphology and expressions of osteogenesis factors, and to evaluate RGD peptides promotes junctura ossium of tantalum-bone interface in vivo. METHODS RGD peptides of different concentrations (1 g/L, 5 g/L, and 10 g/L) were loaded to porous tantalum slices with a diameter of 10 mm and a thickness of 3 mm by physical absorption. The 3rd generation of MG63 cells were co-cultured with tantalum and divided into 4 groups: Ta-cells (control) group, 1 g/L cells/Ta/RGD group, 5 g/L cells/Ta/RGD group, and 10 g/L cells/Ta/RGD group. Porous tantalum compo-sites and osteoblasts-tantalum interface were observed by scanning electron microscopy. The adhesion rate of osteoblasts was detected and immunocytochemistry was used to detect the expressions of filamentous actin (F-actin), osteocalcin (OC) and fibronectin (FN). RESULTS The scanning electron microscope (SEM) revealed that osteoblasts distributed on the surface of porous tantalum and secreted extracellular matrix on outside and inner of micro-pores. The osteoblasts adhesion rate on porous tantalum modified with RGD was higher than that in the unmodified porous tantalum at the end of 24, 48, and 72 hours. The best adhesion effect was got in 5 g/L cells/Ta/RGD group at hour 48 [(68.07±3.80) vs. (23.40±4.39), P<0.05]. The results of immunocytochemistry showed that the expressions intensity of F-actin, OC and FN in osteoblasts on porous tantalum modified groups with RGD were stronger than that in the unmodified groups, and the expressions of 5 g/L cells/Ta/RGD group were significantly higher than those in the 10 g/L group and 1 g/L group [OC: (18.08±0.08) vs. (15.14±0.19), P<0.05; (18.08±0.08) vs. (14.04±0.61), P<0.05. FN: (24.60±0.98) vs. (15.90±0.53), P<0.05; (24.60±0.98) vs. (15.30±0.42), P<0.05. F-actin: (29.20±1.31) vs. (24.50±1.51), P<0.05; (29.20±1.31) vs. (16.92±0.40), P<0.05]. Correspondingly F-actin in osteoblasts was showed in longitudinal arrangement, and the expressions intensity was stronger than those OC and FN. CONCLUSION The RGD peptides is beneficial to enhance adhesion of osteoblast, spreading and reorganization of cytoskeleton on porous tantalum surface and improve the interface morphology, further promoting osteoblasts-tantalum conjunctive interface osseointegration.
Collapse
|
52
|
Bohl DD, Brown NM, McDowell MA, Levine BR, Sporer SM, Paprosky WG, Della Valle CJ. Do Porous Tantalum Metaphyseal Cones Improve Outcomes in Revision Total Knee Arthroplasty? J Arthroplasty 2018; 33:171-177. [PMID: 28844630 DOI: 10.1016/j.arth.2017.07.033] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2016] [Revised: 07/17/2017] [Accepted: 07/20/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Some authors have advocated for use of porous tantalum metaphyseal cones to manage bone defects during revision total knee arthroplasty (TKA). The purpose of this study is to compare results with porous metaphyseal cones to results with traditional hybrid stem fixation in revision TKA. METHODS Forty-nine patients undergoing revision TKA with femoral and/or tibial metaphyseal cones (39 tibial only, 3 femoral only, 7 both) were matched by surgical indication to 49 patients undergoing revision TKA with a traditional hybrid stem (non-cone) technique. Clinical and radiographic outcomes were compared at a minimum of two-year follow-up (mean 3.5 years) with adjustment for baseline characteristics. RESULTS Pre-revision bone defects and most baseline demographics were similar between the cone and non-cone cohorts suggesting appropriate matching. Patients in the non-cone cohort had greater pre- to post-operative increases in Knee Society Score (37.2 ± 18.6 vs 28.4 ± 17.8, P = .010) and Knee Society Functional Score (30.4 ± 24.3 vs 13.1 ± 27.6, P = .003). The cohorts did not differ with respect to complications, subsequent reoperation, subsequent revision, patient satisfaction, tibial overhang, the presence of radio-sclerotic lines, cortical hypertrophy around the stems, or tibial subsidence. CONCLUSION In this series, metaphyseal cones were not associated with superior outcomes at short-term follow-up. Given the increased cost associated with use of cones compared to traditional techniques, this study cannot support the routine use of metaphyseal cones in revision TKA. Longer-term follow-up will be necessary to determine if construct durability differs over the long term.
Collapse
|
53
|
Chen Z, Zheng L, Cao W, Chen X, Chen R, Li R, Shung K, Zhou Q. High-Frequency Ultrasonic Imaging with Lead-free (Na,K)(Nb,Ta)O 3 Single Crystal. ULTRASONIC IMAGING 2017; 39:348-356. [PMID: 28395599 DOI: 10.1177/0161734617701069] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Lead-free (Na,K)(Nb,Ta)O3 (KNNT) piezoelectric single crystal has been successfully grown using the top-seeded solution growth technique. The electromechanical coupling factors are very high ( k33 = 0.827, kt = 0.646), and the dielectric loss tangent is as low as 0.004. Acoustic impedance was calculated to be 26.5 MRayl. From the single crystal, a single element transducer was fabricated. The transducer achieved a 57.6% -6 dB bandwidth and 32.3 µm axial resolution at the center frequency of 45.4 MHz, which can identify the cornea of porcine eyeball with high resolution. Comparison between KNNT single crystal and lead-based single crystal was discussed. The results suggest that this single crystal transducer is an excellent candidate to replace lead-containing transducer for high-frequency ultrasonic imaging applications.
Collapse
|
54
|
Wang H, Wang Q, Zhang H, Shi W, Lai Z, Cui Y, Li Q, Wang Z. [Repair of segmental bone defects in rabbits' radius with domestic porous tantalum encapsulated with pedicled fascial flap]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2017; 31:1200-1207. [PMID: 29806321 PMCID: PMC8498136 DOI: 10.7507/1002-1892.201611048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Revised: 09/01/2017] [Indexed: 11/03/2022]
Abstract
Objective To investigate the effect of domestic porous tantalum encapsulated with pedicled fascial flap on repairing of segmental bone defect in rabbits' radius. Methods A total of 60 New Zealand white rabbits (aged 6- 8 months and weighing 2.5-3.0 kg) were randomly divided into the experimental group and control group (30 rabbits each group). A 1.5 cm segmental bone defect in right radius was established as the animal model. The porous tantalums encapsulated with pedicled fascial flaps (30 mm×20 mm) were implanted in the created bone defect in the experimental group, and the porous tantalums were only implanted in the control group. X-ray films were observed at the day after operation and at 4, 8, and 16 weeks after operation. Specimens were taken out at 4, 8, and 16 weeks after operation for HE staining and toluidine blue staining observation. The maximum load force and bending strength were detected by three point bending biomechanical test, and the Micro-CT analysis and quantitative analysis of the new bone volume fraction (BV/TV) were performed at 16 weeks after operation to compare the bone defect repair ability in vivo in 2 groups. Results All incisions healed by first intention without wound infection. At 4, 8, and 16 weeks after operation, the X-ray films showed that the implants were well maintained without apparent displacement. As followed with time, the combination between the implants and host bone became more and more closely, and the fracture line gradually disappeared. HE staining and toluidine blue staining showed that new bone mass and maturity gradually increased at the interface and inside materials in 2 groups, and the new bone gradually growed from the interface to internal pore. At 16 weeks after operation, the three point bending biomechanical test showed that the maximum load force and bending strength in the experimental were (96.54±7.21) N and (91.26±1.76) MPa respectively, showing significant differences when compared with the control group [(82.65±5.65) N and (78.53±1.16) MPa respectively] ( t=3.715, P=0.004; t=14.801, P=0.000). And Micro-CT analysis exhibited that there were a large amount of new bone at the interface and the surface of implant materials and inside the materials. The new bone BV/TV in the experimental group (32.63%±3.56%) was significantly higher than that in control group (25.07%±4.34%) ( t=3.299, P=0.008). Conclusion Domestic porous tantalum encapsulated with pedicled fascial flap can increase local blood supply, strengthen material bone conduction ability, and promote the segmental bone defect repair.
Collapse
|
55
|
Filella M, Rodríguez-Murillo JC. Less-studied TCE: are their environmental concentrations increasing due to their use in new technologies? CHEMOSPHERE 2017; 182:605-616. [PMID: 28525874 DOI: 10.1016/j.chemosphere.2017.05.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 04/10/2017] [Accepted: 05/03/2017] [Indexed: 05/23/2023]
Abstract
The possible environmental impact of the recent increase in use of a group of technology-critical elements (Nb, Ta, Ga, In, Ge and Te) is analysed by reviewing published concentration profiles in environmental archives (ice cores, ombrotrophic peat bogs, freshwater sediments and moss surveys) and evaluating temporal trends in surface waters. No increase has so far been recorded. The low potential direct emissions of these elements, resulting from their absolute low production levels, make it unlikely that the increasing use of these elements in modern technology has any noticeable effect on their environmental concentrations on a global scale. This holds particularly true for those of these elements that are probably emitted in relatively high amounts from other human activities (i.e., coal combustion and non-ferrous smelting), such as In, the most studied element of the group.
Collapse
|
56
|
Buchmann J, Guggenheim J, Zhang E, Scharfenorth C, Spannekrebs B, Villringer C, Laufer J. Characterization and modeling of Fabry-Perot ultrasound sensors with hard dielectric mirrors for photoacoustic imaging. APPLIED OPTICS 2017; 56:5039-5046. [PMID: 29047652 DOI: 10.1364/ao.56.005039] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A Fabry-Perot ultrasound sensor with nonhygroscopic dielectric mirrors made out of Ta2O5 and SiO2 for use in photoacoustic tomography is described. The sensor offers flat frequency response up to 36 MHz, low noise-equivalent pressure (70 Pa), and near-omnidirectional response up to 20 MHz as well as optical transparency for near-infrared illumination. A numerical model was developed to predict its frequency response, and the results were validated experimentally. An image of the human palm was acquired to demonstrate in vivo imaging capabilities.
Collapse
|
57
|
Bryndahl F, Eriksson L, Legrell PE, Isberg A. Bilateral TMJ Disk Displacement Induces Mandibular Retrognathia. J Dent Res 2016; 85:1118-23. [PMID: 17122165 DOI: 10.1177/154405910608501210] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Unilateral non-reducing TMJ disk displacement has been shown to retard mandibular growth on the ipsilateral side, with facial asymmetry a sequela. We hypothesized that bilateral affliction would impair mandibular growth bilaterally, generating mandibular retrognathia. Non-reducing TMJ disk displacement was surgically created in 10 growing New Zealand White rabbits. Ten additional rabbits served as a sham-operated control group. Facial growth was followed in serial cephalograms, with tantalum implants, during a period corresponding to childhood and adolescence in man. The results verified that bilateral non-reducing TMJ disk displacement retarded mandibular growth bilaterally, the extent corresponding to mandibular retrognathia in man. Maxillary growth was also retarded, but to a lesser degree. Growth impairment fluctuated over time, the most striking retardation occurring during periods of general growth acceleration. This should be taken into consideration when orthodontic treatment, aimed at stimulating mandibular growth, is initiated in adolescent individuals with non-reducing TMJ disk displacement.
Collapse
|
58
|
Ivaldo N, Mangano T, Caione G, Rossoni M, Ligas A. Customized tantalum-augmented reverse shoulder arthroplasty for glenoid bone defect and excessive medialization: description of the technique. Musculoskelet Surg 2016; 100:13-18. [PMID: 27900710 DOI: 10.1007/s12306-016-0404-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Accepted: 04/07/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND Glenoid bone defect and excessive medialization could represent challenging issues during reverse shoulder arthroplasty, especially in the setting of revision surgery. Although a solution is offered by the Boileau's BIO-RSA technique in primary cases, only autologous iliac crest bone graft and homologous graft from bone banks are available for revision surgeries, with known disadvantages and risk of graft resorption and implant failure. MATERIALS AND METHODS We describe in this work a new technique based on a customized porous tantalum device to be used in salvage situations, aimed at lateralization of the glenoid component of a reverse shoulder arthroplasty. Between 2014 and 2015, five patients received a customized tantalum-augmented RSA at our institution. The augments we applied are actually on the market for acetabular bone loss management: these were opportunely prepared and fixed to the metal back of the glenoid component before implantation. RESULTS In the five cases treated, no major or minor complications have been recorded to date. Despite the short follow-up, all the implants are still in situ. All of the patients referred complete subjective satisfaction and return to their daylife activities without pain within 4 months after surgery. CONCLUSIONS The customized tantalum-augmented RSA technique represents in our experience a useful and safe solution in managing glenoid bone loss and medialization. Adaptability to virtually every device in the market should be regarded as important point of strength of this technique.
Collapse
|
59
|
Sivasubramanian H, Kini SG, Ang KY, Sathappan SS. Use of tantalum cones in primary arthroplasty of acute proximal tibial fractures. Acta Orthop Belg 2016; 82:593-598. [PMID: 29119902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Metaphyseal tantalum cones in primary total knee arthroplasty and their functional outcome is described using 3 case reports over 6 years. 3 knees in 3 elderly individuals (mean age of 70.4 years), with pre-existing osteoarthritis and complex proximal tibial fractures, were operated on. Ambulation with walking frame was achieved from post-operation day 1, with weight-bearing as tolerated. Mean range of motion was 122° and Mean Knee Society Score was 88. All showed improvement in pre-operative limb alignment. Radiological fracture union was achieved on an average of 3 months. All were independent ambulators and pain-free at the latest follow-up. Our case series shows that tantalum cones are associated with significant improvements in clinical scores, patient symptoms, range of movement, early weight-bearing and low rates of complications in complex proximal tibial fractures with poor bone stock.
Collapse
|
60
|
Fu WM, Yang L, Wang BJ, Xu JK, Wang JL, Qin L, Zhao DW. Porous tantalum seeded with bone marrow mesenchymal stem cells attenuates steroid-associated osteonecrosis. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2016; 20:3490-3499. [PMID: 27608912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
OBJECTIVE Bone marrow mesenchymal stem cells (BMMSCs) have been widely applied in osteonecrosis. However, lack of biomechanical support limited application of BMMSCs. And porous tantalum (PTA) has been identified as a cell-friendly scaffold for bone regeneration. Herein, we aimed to investigate the efficacy of PTA seeded with BMMSCs in the treatment of osteonecrosis. MATERIALS AND METHODS After the production of PTA seeded with BMMSCs, MTT and GFP were performed to identify the proliferation and adhesion of BMMSCs respectively, which was further examined by scanning electron microscopy (SEM). And real-time PCR was also used to determine mRNA level of osteogenic markers, including Alp, OCN, OPN, Col I and Runx-2 in BMMSCs. Nineteen adult rabbits were applied for building steroid-associated osteonecrosis (SAON) models. Bone formation rate (BFR) and mineral apposition rate (MAR) were determined. And Goldner Trichrome Staining was used in these SAON models, which further confirmed the efficacy of PTA seeded with BMMSCs in SAON. RESULTS PTA seeded with BMMSCs showed excellent biocompatibility. Additionally, SEM assay showed that BMMSCs adhered tightly and spread fully in the pores of PTA. Next, the expression of ALP and OPN mRNA in BMMSCs were significantly (p < 0.05) higher in the PTA-treated group compared to those in the PTA-untreated group. Furthermore, compared to those treated by only PTA, the dynamic bone formation in rabbits treated by PTA seeded with BMMSCs was significantly increased (p < 0.001) at both week 3rd and week 6th. CONCLUSIONS The product, PTA seeded with BMMSCs, was successfully produced, and was determined as high efficacy for treatment of steroid-associated osteonecrosis. PTA seeded with BMMSCs may afford a promising option for treating osteonecrosis.
Collapse
|
61
|
WARD PH, WEPMAN JM. XLIII Pharyngeal Implants for Reduction of Air Space in Velopharyngeal Insufficiency. Ann Otol Rhinol Laryngol 2016; 73:443-57. [PMID: 14196686 DOI: 10.1177/000348946407300215] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
62
|
Fontaine AB, Koelling K, Passos SD, Cearlock J, Hoffman R, Spigos DG. Polymeric Surface Modifications of Tantalum Stents. J Endovasc Ther 2016; 3:276-83. [PMID: 8800230 DOI: 10.1177/152660289600300306] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: To compare two kinds of polymer-coated tantalum stents with bare tantalum stents (control) to determine if the coatings can improve thromboresistance. Methods: Twenty-seven Fontaine-Dake stents were balloon expanded in three 8-mm × 80-cm.polytetrafluoroethylene (PTFE) grafts; 9 stents were bare tantalum (T); 9 were coated with polyetherurethane (PL); and 9 were coated with parylene (PA). There were 9 stents placed in each graft as follows: 3 tantalum, 3 polyetherurethane, and 3 parylene. In swine whose platelets had been radiolabeled with indium 111, the ends of each stented graft were connected to 14F femoral and venous sheaths to create an ex vivo fistula. Each graft was exposed to blood for 30, 60, and 120 minutes. At the end of each test period, the stented grafts were disconnected from the sheaths, flushed with saline until clear, and then flushed with formalin. The stents were removed from the grafts, and a radionuclide well counter recorded radionuclide counts from each stent type at each period of blood contact. These values were converted to platelet density per 1000 mUm2. Stents were then photographed and scanned with electron microscopy (EM) for qualitative analysis. Possible significant differences in platelet adhesion with the three types of stents (both between stent groups and within stent groups) were examined using a two-tailed Student's f-test. Results: There were significantly fewer platelets adsorbed on PA versus T at all time periods (p < 0.005); on PL versus T at 60 and 120 minutes (p < 0.005); and on PA versus PL at 30 and 120 minutes (p < 0.0005). There was no significant difference in platelet density within each stent group (p = 0.1). Mean platelet density (number of platelets per 1000 mUm2 ± SD) was as follows: at 30 minutes: T = 1891 ± 965; PL = 373 ± 193; and PA = 27 ± 3; at 60 minutes: T = 6226 ± 1621; PL = 1573 ± 793; and PA = 1185 ± 710; at 120 minutes: T = 5307 ± 591; PL = 3164 ± 318; and PA = 180 ± 100. Gross inspection of the 120-minute groups demonstrated focal areas of thrombus on T, less on PL, and none on PA. Scanning EM demonstrated extensive platelet accumulation covering T at all time periods, less on PL, and even less on PA. Conclusions: Polymeric surface modification of tantalum stents with parylene and/or polyetherurethane can improve the acute thromboresistance of these devices; parylene appears to be the more thromboresistant of the two coatings.
Collapse
|
63
|
Tang ZY, Li P, Cha XF. [Short-term effects on reconstruction of Paprosky type III severe acetabulum bone defect with tantalum metal block]. ZHONGGUO GU SHANG = CHINA JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY 2015; 28:1137-1140. [PMID: 26911125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To investigate methods and short-term effects on tantalum metal block for reconstruction of Paprosky type III severe acetabulum bone defect. METHODS Twelve patients (12 hips) with Paprosky type III severe acetabulum bone defect,treated with tantalum metal block in revision of total hip arthroplasty, were retrospectively analyzed from March 2009 to December 2012. Among the patients, there were 5 males and 7 females aged from 45 to 78 years old with an average of 64 years old; the courses of disease ranged from 3 to 32 months with an average of 16 months. According to classification of Paprosky, all patients were Paprosky type III acetabulum bone defect. All patients were used tantalum metal block in revision of total hip arthroplasty, and large diameter biological acetabulum cups were used in combination. Operative time,blood loss and postoperative complications were recorded and compared, Harris score were used to evaluate clinical effects. RESULTS Eleven patients ( 11 hips) were followed up from 9 to 36 months with an average of 25 months, 1 case was lost to follow-up for dying in car accident. The incisions were healed at stage I . Operative time ranged from 2 to 6 h with an average of 3 h; blood loss was 300 to 1 600 ml with an average of 900 ml. No deep venous thrombosis, periprosthetic femoral fracture and infection, sciatic nerve injury occurred after operation. Harris score were improved from (46.25 ± 8.99) before operation to (83.75 ± 6.76) after operation. There was significant difference in Harris score before and after operation (t = 3.14, P = 0.00 < 0.05), and 7 cases got excellent results, 2 good and 2 moderate. CONCLUCSION: Tantalum metal block is suitable for revision of Paprosky III acetabulum bone defect, could repair different kinds of acetabulum cup defect, could fill up inclusive defect of inner wall combined with particulate bone graft, induce bone growth pressured between metal block and metal cup, provide a new further choose for the treatment of Paprosky type III severe acetabulum bone defect.
Collapse
|
64
|
Lee JW, Wen HB, Battula S, Akella R, Collins M, Romanos GE. Outcome after placement of tantalum porous engineered dental implants in fresh extraction sockets: a canine study. Int J Oral Maxillofac Implants 2015; 30:134-42. [PMID: 25615921 DOI: 10.11607/jomi.3692] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE This study evaluated the stability and histologic proof of osseoincorporation of Trabecular Metal (TM) dental implants, which feature a tantalum-based porous midsection. MATERIALS AND METHODS A total of 48 TM implants (test group) and Tapered Screw-Vent implants (control group) were immediately placed bilaterally into mandibular extraction sockets in dogs. Resonance frequency analysis was performed at weeks 0, 2, 4, and 12 after implant placement. Histologic and histomorphometric evaluations of the implant interface were performed. RESULTS Changes in mean implant stability quotients (ISQ) revealed no statistical differences between the test and control groups. Histologic analysis showed bone ingrowth into the porous tantalum structure of all test group implants. Histomorphometric analysis revealed an increased percentage of bone-to-implant contact between 4 and 8 weeks in both test and control groups. The porous sections of the test group exhibited significantly more new bone inside the pores at week 12 in comparison to weeks 2 and 4. No correlation was observed between ISQ and histomorphometric parameters. CONCLUSION In a canine immediate extraction socket model, both test and control implants demonstrated comparable implant stability and bone-to-implant contact. Bone ingrowth was evident within the tantalum porous section of the test implants during the early healing.
Collapse
|
65
|
Liu P, Lv X, Li Y, Lv M. Onyx Embolization of a Ruptured Rotundum Foreman Artery Aneurysm in a Patient with Moyamoya Disease: A Case Report. World Neurosurg 2015; 84:1178.e1-3. [PMID: 26118722 DOI: 10.1016/j.wneu.2015.06.039] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 06/15/2015] [Accepted: 06/16/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Hemorrhage caused by the rupture of a rotundum foreman artery pseudoaneurysm in Moyamoya disease (MMD) is rarely reported. CASE DESCRIPTION We report a case of 46-year-old man with MMD presenting with left temporal lobe hemorrhage. Cerebral angiogram showed a pseudoaneurysm located on the rotundum branch of the left internal maxillary artery, which anastomosed with a pial vessel. Using onyx 18, we successfully embolized the pseudoaneurysm. The patient was discharged neurologically intact. CONCLUSION Given the difficulties and risks of surgery, onyx embolization of rotundum foreman artery aneurysm accompanied with MMD is feasible and effective.
Collapse
|
66
|
Streit JJ, Shishani Y, Greene ME, Nebergall AK, Wanner JP, Bragdon CR, Malchau H, Gobezie R. Radiostereometric and Radiographic Analysis of Glenoid Component Motion After Total Shoulder Arthroplasty. Orthopedics 2015; 38:e891-7. [PMID: 26488784 DOI: 10.3928/01477447-20151002-56] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Accepted: 02/13/2015] [Indexed: 02/03/2023]
Abstract
Aseptic glenoid component loosening is a common cause of total shoulder arthroplasty (TSA) failure, but early detection is difficult because pain often appears late and radiolucent lines are of uncertain significance. This study sought to answer the following questions: (1) What types of glenoid component motion may be observed during the first 3 years following implantation?; (2) Is the appearance of radiolucent lines around the glenoid component a reliable indicator of component motion?; and (3) Are clinical outcomes correlated with early glenoid component motion within the first 3 years after TSA? Eleven patients (mean age, 60.6 years) underwent TSA using a cemented, all-polyethylene glenoid component with tantalum bead implantation. Clinical outcomes (American Shoulder and Elbow Surgeons [ASES] score, visual analog scale [VAS] pain score, and range of motion) were compared pre- and postoperatively, and radiolucencies were graded according to the criteria of Lazarus et al. Patients were evaluated using radiostereometric analysis at 6 months and 1, 2, and 3 years postoperatively to measure component micromotion in translation and rotation. At a mean follow-up of 50.2 months, mean ASES score had improved from 30.3 to 81.3 (P<.001), mean VAS pain score had improved from 8 to 1 (P<.001), active forward flexion had improved from 109° to 155° (P=.001), active external rotation had improved from 28° to 54° (P=.003), and internal rotation had improved from the level of the sacrum to L3 (P=.002). Radiolucencies were detected around none of the components at 1 year, 6 components at 2 years, and 5 components at 3 years, and these radiolucencies were mostly found around components that experienced high levels of rotational motion.
Collapse
|
67
|
Juan YH, Lin YC, Sheng TW, Cheung YC, Ng SH, Yu CW, Wong HF. Application of Onyx for Renal Arteriovenous Malformation With First Case Report of a Renal Hyperdense Striation Sign: A CARE-Compliant Article. Medicine (Baltimore) 2015; 94:e1658. [PMID: 26426661 PMCID: PMC4616815 DOI: 10.1097/md.0000000000001658] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Onyx is an emerging treatment modality for visceral vascular malformations, especially in cases in which delicate nidal penetration of the arteriovenous malformation (AVM) is desired. A computed tomography (CT) image presentation of hyperdense striations along the renal medulla secondary to the tantalum powder has not been previously reported. A 65-year-old woman presented to our institution with intermittent gross hematuria and left flank pain for 10 days. Both CT and conventional angiographies confirmed cirsoid-type renal AVM, which was successfully treated with Onyx. Follow-up CT after treatment revealed presence of hyperdense striations along the renal medulla, which resolved during later image follow-up. Despite its frequent usage in neural intervention, the application of Onyx in visceral AVM is gradually gaining interest, especially in cases in which delicate nidal penetration of the AVM is desired. Renal hyperdense striation sign should be recognized to avoid confusion with embolizer migration, and further studies in patients with renal function impairment may be helpful in understanding its influence of renal function.
Collapse
|
68
|
Cao L, Tan L, Lin X, Wu C, Zeng J. [RECONSTRUCTION MODE SELECTION OF ACETABULAR BONE DEFECT AND EFFECT ON ACETABULAR CUP POSITION IN CEMENTLESS TOTAL HIP ARTHROPLASTY]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2015; 29:693-699. [PMID: 26466470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To investigate the reconstruction mode selection of acetabular bone defect and the effect on the acetabular cup position in cementless total hip arthroplasty (THA). METHODS A retrospective analysis was made on the clinical data of 78 patients (78 hips) with acetabular bone defect according to the selection criteria who underwent THA between February 2008 and February 2014. In 39 cases having acetabular posterosuperior bone defect with defect area less than 30%, impaction bone grafting was performed (group A); in 24 cases having acetabular posterosuperior bone defect with defect area of 30%-50%, structural bone or tantalum block grafting was performed (group B); in 10 cases having acetabular medial wall bone defect with defect area less than 30%, impaction bone grafting was performed (group C); and in 5 cases having acetabular medial wall bone defect with defect area of 30%-50%, titanium mesh combined with impaction bone grafting was performed (group D). There was no significant difference in gender, age, and side between groups A and B, and between groups C and D (P > 0.05). The acetabular abduction angle, anteversion, the horizontal and vertical distances of actual and true rotation center after operation were compared. RESULTS The patients were followed up 7-25 months. Prosthesis loosening occurred in 2 cases of group A, sciatic nerve injury and hip joint dislocation in 1 case of group B, respectively. At immediate after operation and last follow-up, there was no significant differences in the horizontal or vertical distance of actual and the true rotation center between groups A and B (P > 0.05); significant difference was found in the horizontal distance between groups C and D (P < 0.05), but no significant difference in the vertical distance (P > 0.05). Difference was statistically significant in the acetabular abduction angle and anteversion between groups A and B (P < 0.05), but difference was not significant between groups C and D (P > 0.05). CONCLUSION In patients with acetabular posterosuperior bone defect, reconstruction methods will have effect on acetabular abduction and anteversion; early acetabulum prosthesis loosening may be associated with too large acetabular abduction angle and inappropriatejeconstruction methods. In patients with acetabular medial wall bone defect, the vertical distances of rotation center will shift upward in varying degrees, and reconstruction methods have effect on the horizontal distances of rotation center.
Collapse
|
69
|
Zhang H, Li L, Wang Q, Gan HQ, Wang H, Bi C, Li QJ, Wang ZQ. [Influence of BMP-7 on chondrocyte secretion and expression of Col-II,AGG and Sox9 mRNA in porous tantalum-chondrocyte composites in vitro]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2015; 47:219-225. [PMID: 25882933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To study the influence of bone morphogenetic protein-7 (BMP-7) on chondrocyte secretion and expression of type II collagen (Col-II), aggrecan (AGG) and SRY-related high mobility group-box gene 9 (Sox9) mRNA in porous tantalum-chondrocyte composites. METHODS The articular chondrocytes were isolated from 3-week-old New Zealand immature rabbits and identified. The 2nd generation of chondrocytes with 1×10(6)/mL inoculate concentration was seeded in porous tantalum and divided into 4 groups, and control group (tantalum/chondrocyte), 50 μg/L BMP-7 group (50 μg/L BMP-7/tantalum/chondrocyte), 100 μg/L BMP-7 group (100 μg/L BMP-7/tantalum/chondrocyte), and 200 μg/L BMP-7 group (200 μg/L BMP-7/tantalum/chondrocyte). The proliferation of chondrocytes was measured by CCK-8 assay. The chondrocyte growth and morphology were observed by scanning electron microscopy (SEM). The synthesis of glycosaminoglycan (GAG) in chondrocytes was tested by dimethyl methylene blue (DMMB) colorimetric quantification method. Col-II, AGG and Sox9 mRNA in chondrocytes were detected by real-time PCR. RESULTS The chondrocytes were spindle-shaped in 24 hours of primary cell culture and most cells became polygonal shaped in 4 days. The chondrocytes were affirmed by alcian blue, safranin O and Col-II immunocytochemistry staining. The result of CCK-8 assay showed that the level of cell proliferation in 100 μg/L BMP-7 groups were higher than those in the other groups (P<0.05). The chondrocytes implanted into porous tantalum scaffolds with BMP-7 had better functions, by which cytoplasmic processes developed and extended to the surface and inner of porous tantalum by SEM observation. DMMB quantitative determination of GAG showed that GAG amount of chondrocytes in 100 μg/L BMP-7 groups was significantly higher than those in the other groups (P<0.05). The expressions of Col-II, AGG and Sox9 mRNA in chondrocytes were up-regulated in the experimental groups, compared with the control group and the best effect appeared when concentration of BMP-7 was 200 μg/L. (P<0.05). CONCLUSION BMP-7/tantalum/chondrocytes composites enhanced in vitro chondrocyte proliferation and extracellular matrix greatly, and can promote chondrogenic gene expression.
Collapse
|
70
|
Guthy E, Brendel W. Stapling devices and their use in surgery. PROGRESS IN SURGERY 2015; 7:56-113. [PMID: 4891955 DOI: 10.1159/000386299] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
71
|
Abstract
BACKGROUND Although newer generations of total ankle arthroplasty designs have better clinical outcomes, failure due to aseptic loosening remains a frequent major complication. Arthrodesis is the most common salvage procedure for a failed total ankle replacement. There are several arthrodesis techniques each with its advantages and disadvantages. We present a technique of ankle arthrodesis for failed total ankle replacements using tantalum Trabecular Metal™ (Zimmer, Warsaw, IN) with internal fixation, thus sparing the subtalar joint. METHODS Three patients who had undergone arthrodesis for a failed total ankle replacement using tantalum Trabecular Metal were retrospectively reviewed. The mean follow-up period was 57 (range, 31-86) months. The mean age at ankle arthroplasty was 57 (range, 33-72) years and at ankle arthrodesis was 63 (range, 44-74) years. The mean time from arthroplasty to arthrodesis was 7 (range, 2-11) years. RESULTS The American Orthopaedic Foot and Ankle Society (AOFAS) score improved from 30.7 (range, 20-39) preoperatively to 72.7 (range, 65-77) postoperatively at the time of last follow-up. Arthrodesis was achieved at a mean of 3 months, and there were no complications. CONCLUSION The technique described has several advantages when compared to other methods of salvage ankle arthrodesis. The subtalar joint is not included in the fusion unless it is degenerative and symptomatic. Height of the ankle is maintained throughout the fusion process. Furthermore, Trabecular Metal is abundantly available; it avoids donor site morbidity and eliminates the risk of transmissible diseases.
Collapse
|
72
|
Liu Y, Liu S, Zhou S, Su X, Wang C, Cao Y, Jiang W, Cui Q, Wang L. [A modified porous tantalum implant technology for osteonecrosis of the femoral head: survival and prognostic evaluations of conversion into total hip arthroplasty]. ZHONGHUA YI XUE ZA ZHI 2014; 94:2429-2433. [PMID: 25400049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To assess the survival and prognostic significance of various demographic and radiographic parameters for conversion into total hip arthroplasty after treatment with a modified porous tantalum implant technology for early and intermediate stages of osteonecrosis of the femoral head (ONFH). METHODS This study included 45 patients (59 hips) with Steinberg Stage I-IV A ONFH undergoing progressively core decompression, impaction bone grafting of 5 mm-composite bone filling material and inserting of a porous tantalum implant. Weight-bearing was forbidden within the first 3 months after implants. RESULTS A total of 57 hips (44 patients) were available during a mean follow-up period of 44.8 (11-62) months. Their mean age was 43 (21-70) years. The mean Harris hip score significantly improved from 59.93 ± 2.80 preoperative to 77.84 ± 2.95 at the last follow-up (P < 0.001). Overall, 11 hips (19.30%) were converted into total hip arthroplasty. The overall survival rate was 72.49% at 60 months postoperatively. The Cox proportional hazard model revealed that bone marrow edema was an independent prognostic factor related with a conversion into total hip arthroplasty. CONCLUSION Higher survival rates may be obtained from modified tantalum implant technology for early and intermediate stages of ONFH. And prognosis was poor for patients of ONFH with bone marrow edema.
Collapse
|
73
|
Tayyab M, Bagchi S, Ramakrishna B, Mandal T, Upadhyay A, Ramis R, Chakera JA, Naik PA, Gupta PD. Role of target material in proton acceleration from thin foils irradiated by ultrashort laser pulses. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2014; 90:023103. [PMID: 25215835 DOI: 10.1103/physreve.90.023103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Indexed: 06/03/2023]
Abstract
We report on the proton acceleration studies from thin metallic foils of varying atomic number (Z) and thicknesses, investigated using a 45 fs, 10 TW Ti:sapphire laser system. An optimum foil thickness was observed for efficient proton acceleration for our laser conditions, dictated by the laser ASE prepulse and hot electron propagation behavior inside the material. The hydrodynamic simulations for ASE prepulse support the experimental observation. The observed maximum proton energy at different thicknesses for a given element is in good agreement with the reported scaling laws. The results with foils of different atomic number Z suggest that a judicious choice of the foil material can enhance the proton acceleration efficiency, resulting into higher proton energy.
Collapse
|
74
|
Omarova DK. [Functional state of the respiratory system in employees at the tantalum plant]. GIGIENA I SANITARIIA 2014:55-58. [PMID: 25842497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Indices of pulmonary ventilation function in employees at the tantalum plant tended to decrease according to the length of service and type of performed technological operations. Physiological changes of the functional State of the respiratory system were accompanied by pulmonary ventilation disorders of mixed and obstructive types. Changes in indices of respiratory function at the level of distal and proximal airways, including the bronchial tree, wore compensatory-adaptive character in response to the exposure of harmful factors of dust-gas mixture from the tantalum production.
Collapse
|
75
|
Zou L, Jiang J, Yang Y, Chen C, Qu D. [Structural characteristics and biocompatibility of a new nano-Ta-Ti alloy rod fabricated by laser melting technique]. NAN FANG YI KE DA XUE XUE BAO = JOURNAL OF SOUTHERN MEDICAL UNIVERSITY 2014; 34:852-856. [PMID: 24968844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVE To evaluate the structural characteristics and biocompatibility of a novel nano-Ta-Ti alloy rod for its potential application in internal fixation. METHODS Ta coating of a Ti alloy rod with nano-Ta (tantalum) powder was performed using laser melting with symmetrical grooves repleted with nano-Ta powder along the whole length. The microstructure of the cross section of Ta-Ti alloy rod, pore diameter and components of the coating were analyzed using scanning electron microscopy. The influence of this nano-Ta-Ti alloy on proliferation and differentiation of MC3T3-E1 cells was evaluated by MTT cytotoxicity test and ALP activity test. RESULTS Under scanning electron microscope, the Ta-coating surface presented with a gross porous (200-300 µm) structure with dense fusion between Ta particles, and no new element was produced after laser melting. Biocompatibility evaluation showed that Ti alloys with and without Ta coating both promoted the proliferation of MC3T3-E1 cells, but the coated alloy showed better performance and obviously promoted the differentiation of the osteoblasts. CONCLUSION Alloying between Ta and Ti can be accomplished successfully by laser melting technique, and the alloy obtained has ideal surface structure and good biocompatibility.
Collapse
|