76
|
Finkenzeller T, Techert J, Lenhart M, Link J, Feuerbach S. [CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients]. ROFO-FORTSCHR RONTG 2001; 173:920-3. [PMID: 11588680 DOI: 10.1055/s-2001-17588] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
UNLABELLED CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients. PURPOSE Retrospective evaluation of the safety and effectivity of CT-guided percutaneous thoracal sympathicolysis (CT-TSL) in the treatment of patients with peripheral arterial occlusive disease (PAOD) of the upper limb and chronic thoracal pain syndromes. Comparison of our own experience with literature reports. MATERIAL AND METHODS Between 6/96 and 12/99, 4 patients with PAOD of the upper limb and two with chronic thoracal pain syndromes caused by herpes zoster were treated by unilateral CT-TSL. RESULTS 18, 21 and 32 months after the intervention 3 out of 4 patients treated for PAOD reported subjective improvements, and one remained unchanged. Two patients treated for pain syndromes showed no long-term benefit of the procedure. There were no serious complications. CONCLUSION The CT-TSL is an alternative method in the treatment of PAOD in patients who are unsuitable for treatment by revascularization.
Collapse
|
77
|
Link J, Manke C. [The endoleak problem in endoluminal therapy]. Radiologe 2001; 41:798-803. [PMID: 11593805 DOI: 10.1007/s001170170095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Endovascular treatment of aortic aneurysms with stent grafts was performed increasingly in recent years. The most frequent complication after endovascular therapy of aortic aneurysms is an endoleak. In case of a persistent endoleak, diameter of the aneurysm is increasing with a high risk of aneurysm ruptur. Diagnostic tools are spiral computed tomography and angiography. Spiral computed tomography is the most sensitive method for the diagnosis of an endoleak ad should be performed with a biphasic acquisition. In- and outflow of sidebranches can be identified correctly with selective angiography in 86%. Perigraft endoleaks should be treated in any case. Patent side branches generally are observed over a period of 6 months. After 6 months approximately half of these endoleaks are thrombosed. Is there an increasing of the diameter of the aneurysm or any changing in the morphology of the aneurysm there is an indication for embolisation of these sidebranches of the aneurysmal sac. Preinterventional embolisation of patent sidebranches is under discussion. Type I endoleaks can be managed by additional stent-graft implantation or coil embolisation. In case of type II endoleaks in- ad outflow vessels should be embolised with coils. Therapy of type III endoleak is performed mostly by additional stent-graft placement. The total incidence of secondary interventions in the Eurostar-study was nearly 10% per year.
Collapse
|
78
|
Volkel H, Scholz M, Link J, Selzle M, Werner P, Tunnemann R, Jung G, Ludolph AC, Reuter A. Superoxide dismutase mutations of familial amyotrophic lateral sclerosis and the oxidative inactivation of calcineurin. FEBS Lett 2001; 503:201-5. [PMID: 11513882 DOI: 10.1016/s0014-5793(01)02730-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Approximately 10% of all familial cases of amyotrophic lateral sclerosis (fALS) are linked to mutations in the SOD1 gene, which encodes the copper/zinc superoxide dismutase (CuZnSOD). Recently, wild-type CuZnSOD was shown to protect calcineurin, a calcium/calmodulin-regulated phosphoprotein phosphatase, from inactivation by reactive oxygen species. We asked whether the protective effect of CuZnSOD on calcineurin is affected by mutations associated with fALS. For this, we monitored calcineurin activity in the presence of mutant and wild-type SOD. We found that the degree of protection against inactivation of calcineurin by different SOD mutants correlates with the severity of the phenotype associated with the different mutations, suggesting a potential role for calcineurin-SOD1 interaction in the etiology of fALS.
Collapse
|
79
|
Abstract
Endovascular treatment of aortic aneurysms with stent grafts was performed increasingly in recent years. The most frequent complication after endovascular therapy of aortic aneurysms is an endoleak. In case of a persistent endoleak, diameter of the aneurysm is increasing with a high risk of aneurysm rupture. Diagnostic tools are spiral computed tomography and angiography. Spiral computed tomography is the most sensitive method for the diagnosis of an endoleak ad should be performed with a biphasic acquisition. In- and outflow of sidebranches can be identified correctly with selective angiography in 86%. Perigraft endoleaks should be treated in any case. Patent side branches generally are observed over a period of 6 months. After 6 months approximately half of these endoleaks are thrombosed. Is there an increasing of the diameter of the aneurysm or any changing in the morphology of the aneurysm there is an indication for embolisation of these sidebranches of the aneurysmal sac. Preinterventional embolisation of patent sidebranches is under discussion. Type I endoleaks can be managed by additional stent-graft implantation or coil embolisation. In case of type II endoleaks in- ad outflow vessles should be embolised with coils. Therapy of type III endoleak is performed mostly by additional stent-graft placement. The total incidence of secondary interventions in the Eurostar-study was nearly 10% per year.
Collapse
|
80
|
Völk M, Strotzer M, Lenhart M, Seitz J, Manke C, Feuerbach S, Link J. Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses. Radiology 2001; 220:484-8. [PMID: 11477257 DOI: 10.1148/radiology.220.2.r01au38484] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.
Collapse
|
81
|
Framme C, Spiegel D, Roider J, Sachs HG, Lohmann CP, Butz B, Link J, Gabel VP. [Central retinal artery occlusion. Importance of selective intra-arterial fibrinolysis]. Ophthalmologe 2001; 98:725-30. [PMID: 11552411 DOI: 10.1007/s003470170079] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Conventional treatment of a central retinal artery occlusion usually has a poor prognosis but intra-arterial fibrinolysis (IF) of the ophthalmic artery is an invasive treatment option. The importance of IF was evaluated in 62 patients with central retinal artery occlusion and in addition the risk spectrum for this disease was considered. MATERIAL AND METHODS Data from charts of 62 patients were retrospectively analysed. Visual recovery after IF (n = 17) was compared to conventional treatment (e.g. decrease of IOP, improvement of rheological conditions, n = 45). Patients were excluded from IF if the occlusion was present for more than 8 h, if there was a history of bleeding and previous operations, or if they were older than 85 years. IF was performed using either urokinase (n = 7) or tPA (n = 10). RESULTS Out of 62 patients, 22 (35%) with central retinal artery occlusion underwent catheterisation. Stenosis of the carotid artery excluded IF in 5 out of these 22 cases, therefore only 17 patients were treated by IF. Of the patients, 40 (65%) were excluded from IF for various reasons: 47% (19/40) arrived later than 8 h after occlusion, 17% (7/40) did not consent to IF, 15% (6/40) had medical contraindications and 13% (5/40) were over 85 years of age. Two patients required no IF because of a cilioretinal anastomosis with moderate visual acuity and another patient showed spontaneous visual recovery during ophthalmic examination. Of the 17 patients treated with IF, 4 achieved an improvement of visual acuity by more than 2 lines, no change of visual acuity was observed in 12/17 patients and 1/17 lost more than 2 lines after treatment. Of the 45 conservatively treated patients, 16 achieved improvement by more than 2 lines and no change occurred in 29/45 patients. Three patients treated with IF suffered from a stroke during treatment. The main risk factor for central retinal artery occlusion was high blood pressure in 32% of all cases and nicotine abuse in 16%. CONCLUSIONS Many patients presented too late for IF. However, there was no statistical difference between patients with IF and conventional treatment with regards to the improvement of visual acuity. Additionally there is an increased risk of a stroke from IF, therefore a prospective study is necessary to evaluate the importance of IF. Stabilisation of high blood pressure may be the best prophylaxis for preventing a central retinal artery occlusion.
Collapse
|
82
|
Djavidani B, Manke C, Lenhart M, Zorger N, Finkenzeller T, Feuerbach S, Link J. [Treatment of para-ostium renal artery stenoses with a new, solidly premounted balloon expandable stent]. ROFO-FORTSCHR RONTG 2001; 173:619-25. [PMID: 11512234 DOI: 10.1055/s-2001-15842] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE Evaluation of the handling, technical success rate, and six-months patency rate of a new, premounted balloon-expandable stent in ostial renal artery stenoses. MATERIAL AND METHODS In a prospective study, 27 ostial renal artery stenoses in 20 patients were primarily treated with the new "Renal Bridge Stent" (Medtronic AVE, Düsseldorf). All patients had a history of hypertension and 8 patients had renal dysfunction. The handling and visibility of the stent was scored on a three grade scale by the operators. Follow-up angiography including intra-arterial trans-stenotic pressure measurements was performed in 23 out of 27 stenoses (17 patients). RESULTS Handling and visibility were scored as good by all operators. 26 of 27 stenoses were treated with technical success by implantation of 28 stents. The mean degree of stenosis was reduced from 74.2% to less than 5%. At 6 months, 8 stents out of 23 (35%) showed a significant in-stent stenosis (stenosis degree > 50% and intra-arterial pressure gradient > 10 mmHg). The stenosis rates were 63% using 5-mm stents, 30% using 6-mm stents, and 0% using 7-mm stents. CONCLUSION Endovascular treatment of ostial renal artery stenosis with the used stent is safe and effective. The new stent shows a good handling and visibility. The high rate of in-stent stenoses might be explained by the rigid follow-up protocol including angiography, trans-stenotic pressure measurements, and the high number of 5-mm vessels in our study.
Collapse
|
83
|
Manke C, Kobuch R, Lenhart M, Strotzer M, Merk J, Birnbaum F, Feuerbach S, Link J. [Percutaneous transfemoral implantation of a new, flexible thoracic aorta endoprosthesis using a percutaneous suture system for vascular suture--initial experiences]. ROFO-FORTSCHR RONTG 2001; 173:442-7. [PMID: 11414153 DOI: 10.1055/s-2001-13341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoral access. PATIENTS AND METHODS Five patients were treated endovascularly with a stent-graft for an aneurysm (n = 3) or acute dissection (n = 2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. RESULTS The aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutely ruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. CONCLUSION The percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited.
Collapse
|
84
|
Manke C, Nitz WR, Djavidani B, Strotzer M, Lenhart M, Völk M, Feuerbach S, Link J. MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. Radiology 2001; 219:527-34. [PMID: 11323483 DOI: 10.1148/radiology.219.2.r01ma03527] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the feasibility of magnetic resonance (MR) imaging-guided stent placement in iliac arterial stenoses. MATERIALS AND METHODS Thirteen patients with 14 iliac arterial stenoses were examined prospectively. Angioplasty was performed through a femoral sheath by using a conventional 1.5-T MR imaging system. Stents and catheters were visualized on the basis of their artifacts. Nitinol stents were placed with gradient-echo MR imaging guidance. Angioplasty balloons were inflated with gadolinium-based contrast material. Results were evaluated clinically and with both digital subtraction angiography (DSA) and contrast material-enhanced MR angiography. RESULTS Ten of 13 patients were treated with technical success by using MR imaging-guided intervention alone. Three patients were treated with additional fluoroscopic guidance, because complications (ie, panic attack, subintimal recanalization, and stent misplacement) occurred with MR guidance. The quality of the postinterventional contrast-enhanced MR angiograms of three of 12 lesions with stents was limited owing to stent-induced signal loss of the lumen. The mean stenosis degree after stent placement was significantly higher at contrast-enhanced MR angiography than at DSA (24.6% vs 6.2%). The mean MR imaging-guided procedure time was 74 minutes. CONCLUSION MR imaging-guided stent placement in iliac arteries is feasible in select patients. The presented technique has limitations-that is, long procedure times, lack of real-time monitoring, and stent artifacts-that necessitate further modifications before it can be recommended for clinical use.
Collapse
|
85
|
Katz BA, Elrod K, Luong C, Rice MJ, Mackman RL, Sprengeler PA, Spencer J, Hataye J, Janc J, Link J, Litvak J, Rai R, Rice K, Sideris S, Verner E, Young W. A novel serine protease inhibition motif involving a multi-centered short hydrogen bonding network at the active site. J Mol Biol 2001; 307:1451-86. [PMID: 11292354 DOI: 10.1006/jmbi.2001.4516] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We describe a new serine protease inhibition motif in which binding is mediated by a cluster of very short hydrogen bonds (<2.3 A) at the active site. This protease-inhibitor binding paradigm is observed at high resolution in a large set of crystal structures of trypsin, thrombin, and urokinase-type plasminogen activator (uPA) bound with a series of small molecule inhibitors (2-(2-phenol)indoles and 2-(2-phenol)benzimidazoles). In each complex there are eight enzyme-inhibitor or enzyme-water-inhibitor hydrogen bonds at the active site, three of which are very short. These short hydrogen bonds connect a triangle of oxygen atoms comprising O(gamma)(Ser195), a water molecule co-bound in the oxyanion hole (H(2)O(oxy)), and the phenolate oxygen atom of the inhibitor (O6'). Two of the other hydrogen bonds between the inhibitor and active site of the trypsin and uPA complexes become short in the thrombin counterparts, extending the three-centered short hydrogen-bonding array into a tetrahedral array of atoms (three oxygen and one nitrogen) involved in short hydrogen bonds. In the uPA complexes, the extensive hydrogen-bonding interactions at the active site prevent the inhibitor S1 amidine from forming direct hydrogen bonds with Asp189 because the S1 site is deeper in uPA than in trypsin or thrombin. Ionization equilibria at the active site associated with inhibitor binding are probed through determination and comparison of structures over a wide range of pH (3.5 to 11.4) of thrombin complexes and of trypsin complexes in three different crystal forms. The high-pH trypsin-inhibitor structures suggest that His57 is protonated at pH values as high as 9.5. The pH-dependent inhibition of trypsin, thrombin, uPA and factor Xa by 2-(2-phenol)benzimidazole analogs in which the pK(a) of the phenol group is modulated is shown to be consistent with a binding process involving ionization of both the inhibitor and the enzyme. These data further suggest that the pK(a) of His57 of each protease in the unbound state in solution is about the same, approximately 6.8. By comparing inhibition constants (K(i) values), inhibitor solubilities, inhibitor conformational energies and corresponding structures of short and normal hydrogen bond-mediated complexes, we have estimated the contribution of the short hydrogen bond networks to inhibitor affinity ( approximately 1.7 kcal/mol). The structures and K(i) values associated with the short hydrogen-bonding motif are compared with those corresponding to an alternate, Zn(2+)-mediated inhibition motif at the active site. Structural differences among apo-enzymes, enzyme-inhibitor and enzyme-inhibitor-Zn(2+) complexes are discussed in the context of affinity determinants, selectivity development, and structure-based inhibitor design.
Collapse
|
86
|
Manke C, Hackethal S, Müller-Hülsbeck S, Djavidani B, Heller M, Link J. [Results after placement of Memotherm stents in iliac and femoral arteries]. ROFO-FORTSCHR RONTG 2001; 173:240-4. [PMID: 11293867 DOI: 10.1055/s-2001-11598] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE To evaluate the effectivity, safety and midterm patency rates of iliac and femoral stent placement with the Memotherm stent (Bard-Angiomed, Karlsruhe). MATERIAL AND METHODS In 41 patients (11 female, 30 male, mean age 63.9 years) 49 lesions were treated with 50 stents. Mean lesion length was 4.8 cm for 5 occlusions and 3.1 cm for 44 stenoses. Lesions were located in the common iliac (n = 31), the external iliac (n = 15), and the common femoral artery (n = 3). Patients were followed-up clinically, with ankle-brachial indices (ABI), and angiography. Angiographic patency rates (< or = 50% restenosis) were calculated using the Kaplan-Meier method, ABIs were compared before and after therapy with the Wilcoxon test. RESULTS An immediate technical success was achieved in 48/49 lesions (98%, intention-to-treat). Visibility of the stent was poor. Four stent placement procedures were complicated by an advancement of the stent, which could not be corrected. A thrombosis of one stent during deployment had to be treated surgically. After a mean of 10.4 months (6-24) 33 lesions were followed-up with angiography. The primary angiographic patency rate was determined to be 89.9% after 9 months. An improvement of at least one Fontaine stage was observed in 85.4%. The mean ABI increased significantly from 0.64 to 0.84 after therapy. CONCLUSIONS The patency rate of the Memotherm stent is comparable to that of other stent systems. The poor visibility and the advancement of the stent during deployment requires further modifications.
Collapse
|
87
|
Jahnke T, Link J, Müller-Hülsbeck S, Grimm J, Heller M, Brossman J. Treatment of infrapopliteal occlusive disease by high-speed rotational atherectomy: initial and mid-term results. J Vasc Interv Radiol 2001; 12:221-6. [PMID: 11265887 DOI: 10.1016/s1051-0443(07)61829-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
PURPOSE To assess the effectiveness and patency rates of high-speed rotational atherectomy (HSRA) for the treatment of infrapopliteal arterial occlusive disease. MATERIAL AND METHODS During an 18-month period, a total of 19 infrapopliteal lesions in 15 consecutive patients were treated primarily by HSRA with use of the Rotablator device. Patients were followed up with documentation of clinical symptoms, standardized treadmill exercise, and Doppler sonography at 1, 3, and 6 months. Control angiography was performed 6 months after primary treatment. RESULTS HSRA was initially successful in 14 of 15 patients, yielding an initial technical success rate of 94%. Percutaneous treatment induced an improvement of the ankle-brachial index (ABI) from 0.6 +/- 0.09 to 0.86 +/- 0.2 after intervention (P < .0001). Doppler analysis showed a mean ABI of 0.85 +/- 0.2 (P < .001) at 1 month, 0.72 +/- 0.2 (P = .012) at 3 months, and 0.7 +/- 0.2 (P = .08) at 6 months after initial therapy. Although six patients were lost to follow-up at various times, control angiography at 6 months was carried out in nine of 15 patients, allowing direct assessment of 12 of 19 treated lesions. Among six high-grade restenoses and five total occlusions in the treated vascular segments, only one arterial lumen (of 12) remained patent without presenting a hemodynamically relevant restenosis. These results led to termination of the study. CONCLUSION Although HSRA for the treatment of infrapopliteal occlusive disease yields a very high initial technical success rate, mid-term results are extremely poor. Therefore, HSRA cannot be recommended for primary treatment of this type of lesion.
Collapse
|
88
|
Zorger N, Manke C, Lenhart M, Völk M, Link J, Feuerbach S. [Percutaneous transpapillary extraction of biliary calculi for symptomatic choledocholithiasisafter unsuccessful endoscopic treatment]. ROFO-FORTSCHR RONTG 2001; 173:92-6. [PMID: 11253093 DOI: 10.1055/s-2001-10890] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE Evaluation of a percutaneous transhepatic treatment of symptomatic choledocholithiasis in bile ducts that cannot be reached with the endoscope. METHODS From January 1996 to August 2000 a transhepatic extraction of biliary calculus was performed in four patients. Endoscopic retrograde cholangiography (ERC) was not successful in any of the cases. Clinical symptoms were icterus in four cases, additional cholangitis or colics in two cases. First, a balloon dilation of the papilla was performed by a percutaneous transhepatic approach. For removal of bile duct stones, occlusion catheters and Dormia baskets were used. Technical success was defined as complete removal of bile duct stones. Clinical success was defined as normalization of cholestasis and inflammation parameters. In the follow-up an ultrasound examination was performed and blood samples were taken for control of cholestasis parameters. RESULTS In all four cases treatment was technically and clinically successful. For complete removal of biliary calculus a second intervention was necessary in two cases. In each case an internal to external drainage was left over a mean of 7 days (3-13 days). In the mean follow-up of 30.5 months (6-50 months) all patients had persistent relief of symptoms. No further interventions were necessary. No complications were present. CONCLUSION Percutaneous transpapillary extraction of biliary calculus is an effective alternative to surgery in patients with bile ducts, that cannot be reached with the endoscope.
Collapse
|
89
|
Nitz WR, Oppelt A, Renz W, Manke C, Lenhart M, Link J. On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J Magn Reson Imaging 2001; 13:105-14. [PMID: 11169811 DOI: 10.1002/1522-2586(200101)13:1<105::aid-jmri1016>3.0.co;2-0] [Citation(s) in RCA: 211] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The interest in performing vascular interventions under magnetic resonance (MR) guidance has initiated the evaluation of the potential hazard of long conductive wires and catheters. The objective of this work is to present a simple analytical approach to address this concern and to demonstrate the agreement with experimental results. The first hypothesis is that a long conductive structure couples with the electric field of the radio frequency (RF) transmit coil. The second hypothesis is that this coupling induces high voltages near the wire ends. These voltages can cause tissue heating due to induced currents. The experimental results show an increase in coupling when moving a guide wire toward the wall of an RF transmit coil, documented with a temperature increase of a saline solution in close proximity to the tip of the guide wire. The coupling of the wire not only presents a potential hazard to the patient, but also interferes with the visualization of the wire. A safe alternative would be the use of nonconducting guide wires. J. Magn. Reson. Imaging 2001;13:105-114.
Collapse
|
90
|
Dinchuk JE, Henderson NL, Burn TC, Huber R, Ho SP, Link J, O'Neil KT, Focht RJ, Scully MS, Hollis JM, Hollis GF, Friedman PA. Aspartyl beta -hydroxylase (Asph) and an evolutionarily conserved isoform of Asph missing the catalytic domain share exons with junctin. J Biol Chem 2000; 275:39543-54. [PMID: 10956665 DOI: 10.1074/jbc.m006753200] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
The mouse aspartyl beta-hydroxylase gene (Asph, BAH) has been cloned and characterized. The mouse BAH gene spans 200 kilobase pairs of genomic DNA and contains 24 exons. Of three major BAH-related transcripts, the two largest (6,629 and 4,419 base pairs) encode full-length protein and differ only in the use of alternative polyadenylation signals. The smallest BAH-related transcript (2,789 base pairs) uses an alternative 3' terminal exon, resulting in a protein lacking a catalytic domain. Evolutionary conservation of this noncatalytic isoform of BAH (humbug) is demonstrated in mouse, man, and Drosophila. Monoclonal antibody reagents were generated, epitope-mapped, and used to definitively correlate RNA bands on Northern blots with protein species on Western blots. The gene for mouse junctin, a calsequestrin-binding protein, was cloned and characterized and shown to be encoded from the same locus. When expressed in heart tissue, BAH/humbug preferably use the first exon and often the fourth exon of junctin while preserving the reading frame. Thus, three individual genes share common exons and open reading frames and use separate promoters to achieve differential expression, splicing, and function in a variety of tissues. This unusual form of exon sharing suggests that the functions of junctin, BAH, and humbug may be linked.
Collapse
MESH Headings
- Amino Acid Sequence
- Animals
- Base Sequence
- Blotting, Northern
- Blotting, Western
- Calcium-Binding Proteins
- Calsequestrin/metabolism
- Carrier Proteins/chemistry
- Carrier Proteins/genetics
- Catalytic Domain
- Cattle
- Cloning, Molecular
- Drosophila
- Embryo, Mammalian/metabolism
- Embryo, Nonmammalian
- Epitopes
- Evolution, Molecular
- Exons
- Humans
- Membrane Proteins
- Mice
- Mixed Function Oxygenases/biosynthesis
- Mixed Function Oxygenases/chemistry
- Mixed Function Oxygenases/genetics
- Mixed Function Oxygenases/metabolism
- Models, Genetic
- Molecular Sequence Data
- Muscle Proteins/chemistry
- Muscle Proteins/genetics
- Myocardium/enzymology
- Oligonucleotides, Antisense/metabolism
- Open Reading Frames
- Poly A/metabolism
- Protein Isoforms
- RNA/metabolism
- RNA, Messenger/metabolism
- Recombinant Proteins/metabolism
- Sequence Homology, Amino Acid
- Stem Cells/metabolism
- Tissue Distribution
Collapse
|
91
|
Biederer J, Link J, Steffens JC, Fronius M, Heller M. [Contrast media-enhanced 3D MR angiography before endovascular treatment of aneurysm in the abdominal aorta, iliac artery and peripheral vessels]. ROFO-FORTSCHR RONTG 2000; 172:985-91. [PMID: 11199442 DOI: 10.1055/s-2000-9214] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE The value of DSA for the measurement of aortic and peripheral arterial aneurysm dimensions before endovascular treatment is limited by projection effects. It was evaluated if additional gadolinium-enhanced three-dimensional MR angiography (3D-CEMRA) could compensate for the disadvantages of DSA. MATERIALS AND METHODS 21 patients with 35 aneurysms in the abdominal aorta (14), iliac (9) and femoropopliteal vessels (12) were assessed with DSA (7 with calibrated catheter, 14 with yardstick) and 3D-CEMRA (TR/TE 7.8/2.1 ms, flip-angle 40 degrees, Matrix 512 x 224, FOV 500 mm, eff. slice 1.8 mm). We measured and compared aneurysm dimensions on both modalities. 3D-CEMRA was regarded as the reference method to evaluate the dimension of DSA-projection effects. RESULTS Diameter and length of aneurysms were underestimated on DSA with the yardstick as reference. The deviation ranged from 15% (+/- 5%) in the aorta to 21% (+/- 10%) in the iliac vessels. Only with calibrated catheters as reference (7/21 DSA), were the distances on DSA correlated well with MRA. In 2/35 aneurysms 3D-CEMRA detected thrombosis with difference between length of inner lumen dilatation on DSA and whole aneurysm length. 2/5 accessory renal arteries found on DSA were not detected on 3D-CEMRA. CONCLUSIONS 3D-CEMRA is a valuable adjunct to DSA for pre-interventional diagnostics of aortic and peripheral arterial aneurysms. It provides exact evaluation of aneurysm dimensions and information about partial thrombosis.
Collapse
|
92
|
Lenhart M, Herold T, Völk M, Seitz J, Manke C, Zorger N, Dorenbeck U, Requardt M, Nitz WR, Kasprzak P, Feuerbach S, Link J. [Contrast media-enhanced MR angiography of the lower extremity arteries using a dedicated peripheral vascular coil system. First clinical results]. ROFO-FORTSCHR RONTG 2000; 172:992-9. [PMID: 11199443 DOI: 10.1055/s-2000-9215] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE To evaluate contrast enhanced magnetic resonance angiography (ceMRA) of the pelvic and peripheral arteries with a dedicated peripheral vascular coil system and automated table-feed technique in patients with arterial occlusive disease. METHODS Three-dimensional gadolinium-enhanced MR angiography in a two-step automatic table feed technique was performed in 45 patients using a 1.5 Tesla imager (Magnetom Symphony, Siemens). The pelvic arteries were imaged with a single injection of contrast material. The upper and the lower leg were imaged with a second injection of contrast material in an automated table feed technique using a dedicated vascular coil system. In 20 patients ceMRA was compared with digital subtraction angiography (DSA) as the standard of reference and in 25 patients ceMRA was performed solely. RESULTS Sensitivity and specificity for grading significant stenoses > or = 50% and occlusions (in parenthesis) were in the pelvic arteries 94.7%, 96.8%, (100%, 100%), in the arteries of the upper leg 92.3%, 93.3% (87.5%, 100%) and in the arteries of the lower leg 96.5%, 95.8%, (95.2%, 96.8%), respectively. Depiction of the runoff vessels of the lower leg was excellent in ceMRA. CeMRA was of diagnostic quality in all the patients. CONCLUSION Contrast-enhanced MRA using a dedicated peripheral vascular coil system increases the diagnostic quality of the lower leg. The runoff vessels can be evaluated. Thus, ceMRA in the presented technique is a diagnostic alternative to arterial angiography.
Collapse
|
93
|
|
94
|
Djavidani B, Lenhart M, Manke C, Finkenzeller T, Zorger N, Feuerbach S, Link J. [Therapy of iliac artery lesions with a new premounted balloon-expandable stent ("Flexible Iliac Bridge Stent")]. ROFO-FORTSCHR RONTG 2000; 172:911-7. [PMID: 11142124 DOI: 10.1055/s-2000-8377] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE Evaluation of the handling, technical success rate and six month patency rate of a new, premounted balloon-expandable stent in iliac artery lesions. MATERIALS AND METHODS In a prospective study 26 stenoses and 3 occlusions of the iliac arteries were primary treated in 24 patients (Fontaine IIa-III, mean age 60.4 year) with the "Flexible Iliac Bridge Stent" (Medtronic AVE, Düsseldorf). Five patients had bilateral stenoses. The ankle-brachial index (ABI) in rest and after exercise was determined before the intervention as well as 1-3 days, 1 and 6 months after the Intervention. The handling and visibility of the stent was scored on a three grade scale by the operators. Follow-up angiography including intraarterial pressure measurement was performed in 17 out of 24 patients (21 out of 29 lesions) after 6 months. RESULTS All 29 lesions were treated with technical success by implantation of 36 stents. The mean degree of the stenoses before intervention was 72.7 +/- 13.8% (+/- 1 standard deviation) and less than 5% in all cases postinterventionally. The mean pressure gradient before and after stent placement was 21 +/- 13.1 mm Hg and 0.8 +/- 2.3 mm Hg, respectively. The Fontaine stage improved by at least one in all patients. The mean ABI at rest improved from 0.63 +/- 0.15 to 0.89 +/- 0.16, and after exercise from 0.46 +/- 0.17 to 0.8 +/- 0.2, respectively. At 6 months 2 lesions out of 21 (9.5%) showed a restenosis of 55% and 70% with an intraarterial pressure gradient of 16 mm Hg and 27 mm Hg, respectively. After 6 months the mean ABI at rest decreased to 0.83 +/- 0.13, and to 0.72 +/- 0.14 after exercise. Handling and visibility was scored as good by all operators. CONCLUSION Endoluminal therapy of iliac artery lesions with the used stent is safe and effective. The six month patency rate is comparable to the published data of other stents.
Collapse
|
95
|
Lenhart M, Völk M, Manke C, Nitz WR, Strotzer M, Feuerbach S, Link J. Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents. Radiology 2000; 217:173-8. [PMID: 11012441 DOI: 10.1148/radiology.217.1.r00se28173] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate signal intensity changes influencing assessment of stent patency at contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METHODS By using an in vitro model, 14 stents-nine nitinol, one tantalum, two stainless steel, and two cobalt alloy-were investigated regarding their appearance at MR imaging. A vascular phantom consisting of tubes filled with 2.00 mmol/L gadopentetate dimeglumine in saline solution was studied in different orientations within the magnetic field. Imaging was performed with a fast three-dimensional gradient-echo sequence (4. 70/1.89 [repetition time msec/echo time msec]). Relative signal intensity reduction within the stents and the degree of artificial narrowing of the stent lumen were calculated. RESULTS The stent lumen was visible within 13 stents. A total signal void inside the stent lumen appeared in only one cobalt alloy stent. Artificial narrowing of the diameter was less than 33% in 10 of 14 stents. The tantalum stent and four nitinol stents seemed best suited for contrast-enhanced MR angiography. A bandlike artifact occurred at the ends of the stents when positioned along the readout direction. CONCLUSION To differentiate between artifacts and stenoses, knowledge of the degree of signal intensity reduction and artificial lumen narrowing within vascular stents is essential. Stent geometry, relative orientation to the magnetic field, and alloy composition influence signal intensity alteration within the stent lumen.
Collapse
|
96
|
Link J, Manke C, Rosin L, Borisch I, Töpel I, Horn M, Mann S, Jauch KW, Bogdahn U, Feuerbach S, Kasprzak P. [Carotid endarterectomy and carotid stenting. A pilot study of a prospective, randomized and controlled comparison]. Radiologe 2000; 40:813-20. [PMID: 11056973 DOI: 10.1007/s001170050828] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
INTRODUCTION A prospective, randomized and controlled trial is conducted to compare carotid endarterectomy and carotid stenting in high grade symptomatic carotid artery stenoses. METHODS According to the study design symptomatic patients with a angiographically high-grade (> or = 70%) internal carotid artery stenosis are included. Pre- and postinterventional diagnostics during the hospitalization period includes neurological assessment, duplex sonography of the cervical and cerebral arteries and magnetic resonance imaging of the brain. Follow-up examinations are scheduled after 1, 6 and 12 months and consist of a neurological assessment and duplex sonography. After 12 months selective angiography and magnetic resonance imaging of the brain will be performed additionally. During a period of 9 months up to now 23/137 patients treated for a carotid artery stenosis were included in the study, 11 patients underwent surgery and 12 patients carotid stenting. RESULTS Carotid stenting and endarterectomy was primarily successful without residual stenosis > 30% in each patient without the occurrence of stroke or death. In 18 follow-up examinations (neurological assessment including duplex sonography) of 13 patients (13 follow-up examinations after 30 days, 5 after 6 months) no relevant restenosis and no stroke occurred. CONCLUSION As of yet, carotid stenting was a safe procedure. Due to the small number of patients a definitive conclusion can not be drawn.
Collapse
|
97
|
Müller B, Link J, Smythe C. Assembly of U7 small nuclear ribonucleoprotein particle and histone RNA 3' processing in Xenopus egg extracts. J Biol Chem 2000; 275:24284-93. [PMID: 10827192 DOI: 10.1074/jbc.m003253200] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In animals, replication-dependent histone genes are expressed in dividing somatic cells during S phase to maintain chromatin condensation. Histone mRNA 3'-end formation is an essential regulatory step producing an mRNA with a hairpin structure at the 3'-end. This requires the interaction of the U7 small nuclear ribonucleoprotein particle (snRNP) with a purine-rich spacer element and of the hairpin-binding protein with the hairpin element, respectively, in the 3'-untranslated region of histone RNA. Here, we demonstrate that bona fide histone RNA 3' processing takes place in Xenopus egg extracts in a reaction dependent on the addition of synthetic U7 RNA that is assembled into a ribonucleoprotein particle by protein components available in the extract. In addition to reconstituted U7 snRNP, Xenopus hairpin-binding protein SLBP1 is necessary for efficient processing. Histone RNA 3' processing is not affected by addition of non-destructible cyclin B, which drives the egg extract into M phase, but SLBP1 is phosphorylated in this extract. SPH-1, the Xenopus homologue of human p80-coilin found in coiled bodies, is associated with U7 snRNPs. However, this does not depend on the U7 RNA being able to process histone RNA and also occurs with U1 snRNPs; therefore, association of SPH1 cannot be considered as a hallmark of a functional U7 snRNP.
Collapse
|
98
|
Völk M, Strotzer M, Holzknecht N, Manke C, Lenhart M, Gmeinwieser J, Link J, Reiser M, Feuerbach S. Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography. Clin Radiol 2000; 55:615-21. [PMID: 10964733 DOI: 10.1053/crad.2000.0493] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 microGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 microGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 microm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 microGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query.
Collapse
|
99
|
Strotzer M, Völk M, Reiser M, Lenhart M, Manke C, Gmeinwieser J, Holzknecht N, Link J, Feuerbach S. Chest radiography with a large-area detector based on cesium-iodide/amorphous-silicon technology: image quality and dose requirement in comparison with an asymmetric screen-film system. J Thorac Imaging 2000; 15:157-61. [PMID: 10928606 DOI: 10.1097/00005382-200007000-00001] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The purpose of this study was to evaluate a large-area, flat-panel X-ray detector, which uses cesium-iodide (CsI) and amorphous silicon (a-Si). Conventional images were compared with digital images acquired with equal dose (2.5 microGy) and with 50% dose reduction. Fifteen consecutive patients were studied prospectively using an asymmetric screen-film system (detector dose, 2.5 microGy). Digital images were taken from the same patients in a posteroanterior view with detector doses of 2.5 and 1.25 microGy, respectively. The CsI/a-Si active-matrix imager had a panel-size of 43 x 43 cm, a matrix of 3 x 3k, and a pixel-pitch of 143 microm. Hard copies were presented in a random order to eight independent observers, who rated image quality according to six subjective quality criteria. Statistical significance of differences was evaluated with Student's t test for paired samples (confidence level, 95%). Digital radiographs with 2.5 and 1.25 microGy were superior to conventional images regarding all quality criteria. Statistically significant differences were observed for five of six criteria at a detector dose of 2.5 microGy and for only one quality feature at 1.25 microGy. Flat-panel digital imagers based on CsI/a-Si technique have the potential to replace conventional systems and might allow a reduction of radiation dose by 50% without loss of image quality.
Collapse
|
100
|
Manke C, Nitz WR, Lenhart M, Völk M, Geissler A, Feuerbach S, Link J. Magnetic resonance monitoring of stent deployment: in vitro evaluation of different stent designs and stent delivery systems. Invest Radiol 2000; 35:343-51. [PMID: 10853608 DOI: 10.1097/00004424-200006000-00002] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate MR imaging features of commercially available stents before, during, and after in vitro deployment as a step toward MR-guided stent deployment. METHODS Fourteen stents were deployed in a phantom under MR monitoring at 1.5 T by using a gradient-echo sequence. Device visibility was rated on a four-point scale (excellent, fair, poor, not visible). RESULTS The Memotherm stent and the rolling membrane (RM) Wallstent showed excellent stent visibility and at least fair scores for artifact-induced narrowing of the stent lumen. Three stents (Palmaz, AVE, Easy Wallstent) showed excellent visibility of the stent but no visible lumen. Five stents (Strecker, Accuflex, Hemobahn, Passager, Sinus) displayed fair visibility. The delivery catheters of four stent systems (Smart, Vascucoil, Symphony, ZA) displayed severe black hole artifacts. CONCLUSIONS The imaging features of several stent systems might be suitable for MR-guided intervention. The Memotherm and the Wallstent RM combine good visibility of the stent and the lumen.
Collapse
|