151
|
Pittet JL, de Moerloose P, Reber G, Durand C, Villard C, Piga N, Rolland D, Comby S, Dupuy G. VIDAS D-dimer: fast quantitative ELISA for measuring D-dimer in plasma. Clin Chem 1996; 42:410-5. [PMID: 8598104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two complementary monoclonal anti-D-dimer antibodies, the second one being labeled with alkaline phosphatase. The upper limit of the measuring range is 1000 micrograms/L and the lower detection limit is <50 micrograms/L, which is below the lower limit of the reference interval (68-494 micrograms/L). Reproducibility (CV) within and between runs ranges from 5% to 7%. There is no interference from heparin, bilirubin, hemoglobin, fibrinogen degradation products, or plasma turbidity. Comparison with a conventional ELISA (y) gave good correlation (r= 0.91, n= 579) and comparable results (y= 1.35x - 148, S(y/x)= 750), especially for D-dimer concentrations ranging from 0 to 1000 micrograms/L (y= 1.09x - 10.6, r= 0.88, S(y/x)= 170).
Collapse
|
152
|
Pittet JL, de Moerloose P, Reber G, Durand C, Villard C, Piga N, Rolland D, Comby S, Dupuy G. VIDAS D-dimer: fast quantitative ELISA for measuring D-dimer in plasma. Clin Chem 1996. [DOI: 10.1093/clinchem/42.3.410] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Abstract
VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two complementary monoclonal anti-D-dimer antibodies, the second one being labeled with alkaline phosphatase. The upper limit of the measuring range is 1000 micrograms/L and the lower detection limit is <50 micrograms/L, which is below the lower limit of the reference interval (68-494 micrograms/L). Reproducibility (CV) within and between runs ranges from 5% to 7%. There is no interference from heparin, bilirubin, hemoglobin, fibrinogen degradation products, or plasma turbidity. Comparison with a conventional ELISA (y) gave good correlation (r= 0.91, n= 579) and comparable results (y= 1.35x - 148, S(y/x)= 750), especially for D-dimer concentrations ranging from 0 to 1000 micrograms/L (y= 1.09x - 10.6, r= 0.88, S(y/x)= 170).
Collapse
|
153
|
Fuchs-Buder T, de Moerloose P, Ricou B, Reber G, Vifian C, Nicod L, Romand JA, Suter PM. Time course of procoagulant activity and D dimer in bronchoalveolar fluid of patients at risk for or with acute respiratory distress syndrome. Am J Respir Crit Care Med 1996; 153:163-7. [PMID: 8542111 DOI: 10.1164/ajrccm.153.1.8542111] [Citation(s) in RCA: 89] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Intraalveolar fibrin deposition is a typical finding in acute lung injury and is not necessarily harmful. However, persistence of intraalveolar fibrin deposit may lead to hyaline membrane formation and subsequent alveolar fibrosis, a histologic hallmark of late stages of acute respiratory distress syndrome (ARDS). Thus, timing of the intraalveolar clotting disorder seems to be critical. To explore the time course of factors contributing to fibrin deposition and resolution, we sequentially analyzed procoagulant activity and fibrin degradation (by D dimer) in bronchoalveolar lavage (BAL) fluid of patients developing ARDS and those at risk for, but finally not developing, the syndrome. A total of 36 bronchoalveolar lavages were performed in 11 patients developing ARDS and 15 lavages in 10 patients at risk for but not developing this syndrome. All patients were admitted to the intensive care unit for the treatment of sepsis, trauma, or shock. In early phases of ARDS, the procoagulant activity (PCA) in BAL was significantly higher than in the patients at risk, 320 +/- 83 U (mean +/- SEM) versus 50 +/- 25 U, p < 0.05. A similar difference was noted in subacute stages (280 +/- 91 versus 46 +/- 16 U, p < 0.05). In early ARDS we observed higher levels of D dimer in BAL than in patients at risk: 1,841 +/- 827 versus 293 +/- 134 ng/ml, p < 0.05. Similarly, values of D dimer in the subacute phase were 2,776 +/- 836 versus 237 +/- 125 ng/ml, p < 0.05. In ARDS as well as in the at-risk group, D dimer in BAL fluid showed good correlation with the polymorphonuclear leukocyte count and with protein content of BAL. There was no correlation between plasma and BAL levels of D dimer. We conclude that in ARDS both the procoagulant pathway and the fibrin degradation are markedly activated compared with these in patients at risk but finally not developing this syndrome. These findings expand our understanding of intraalveolar coagulation abnormalities by providing evidence of increased fibrin breakdown in this syndrome.
Collapse
|
154
|
de Moerloose P, Desmarais S, Bounameaux H, Reber G, Perrier A, Dupuy G, Pittet JL. Contribution of a new, rapid, individual and quantitative automated D-dimer ELISA to exclude pulmonary embolism. Thromb Haemost 1996; 75:11-3. [PMID: 8713772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The performance of a new automated ELISA for a rapid, individual and quantitative measurement of plasma D-dimer (VIDAS D-dimer) has been evaluated. First, a study of 100 patients was performed in order to choose the best couple of antibodies in comparison with an already clinically validated ELISA. Then the results were certified in a prospective study including 195 consecutive patients suspected of pulmonary embolism (PE). For a cut-off level of 500 ng/ml VIDAS D-dimer showed a sensitivity of 100% (95% confidence interval 92-100), a specificity of 37.6%, a negative predictive value of 100% (95% CI 93.3-100) and a positive predictive value of 33.1%. During a 6 months' follow-up no patient (95% CI 0-6.4) with D-dimer < 500 ng/ml presented a new suspicion of venous thromboembolic disease. These results suggest that this rapid and single-dose ELISA provides a very useful tool for the clinician to exclude on a day-to-day basis the diagnosis of PE.
Collapse
|
155
|
Hair GA, Padula S, Zeff R, Schmeizl M, Contrino J, Kreutzer DL, de Moerloose P, Boyd AW, Stanley I, Burgess AW, Rickles FR. Tissue factor expression in human leukemic cells. Leuk Res 1996; 20:1-11. [PMID: 8632672 DOI: 10.1016/0145-2126(95)00107-7] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Patients with acute leukemia are at increased risk for thrombotic and hemorrhagic complications, particularly those patients with acute promyelocytic leukemia (APL) undergoing induction chemotherapy. These serious complications have been attributed by some authors to the release of tissue factor (TF) procoagulant activity (PCA), particularly during cytotoxic chemotherapy. In previous studies of normal peripheral blood cells, only cells of the monocyte lineage have been found to express TF PCA. Therefore, several questions remain regarding the origin and characterization of the PCA in malignant leukemic cells, particularly those thought to be derived from granulocyte progenitor cells. We utilized a full-length cDNA probe, several monoclonal antibodies (MAbs) and a sensitive one-stage PCA assay to study the expression of TF in the human cell line, HL-60, in human peripheral blood monocytes/macrophages (Mo/Mø) and in highly purified populations of human polymorphonuclear leukocytes (PMN). In the HL-60 cells we detected low but significant levels of TF mRNA and TF antigen (TF:Ag). In unstimulated cells, coordinate increased levels of TF mRNA, TF:Ag and TF PCA expression were noted following phorbol-ester-induced macrophage differentiation of the cells, but a decreased level of TF mRNA with no change in the basal level of TF:Ag expression occurred following retinoic acid-induced granulocyte differentiation of this cell line. Long-term cultures of stimulated mature Mo/Mø demonstrated initial coordinate expression of TF mRNA, TF:Ag and TF PCA, but TF:Ag expression persisted even after 7 days (when TF PCA was undetectable). No TF PCA, TF:Ag or TF mRNA was demonstrated in highly purified populations of human PMN, regardless of culture conditions. Discordant expression of TF mRNA, TF:Ag and TF PCA in HL-60 cells suggests the possibility of novel, post-synthetic mechanisms for the regulation of TF PCA expression, which might be dependent on the phenotypic differentiation level of the cell. Such mechanisms (yet to be defined) might account for the ability of some leukemic cells, which frequently express characteristics of more than one cell line (e.g. monocytes and granulocytes), to express a TF gene product capable of activating blood coagulation.
Collapse
|
156
|
Kadry Z, de Moerloose P, Giostra E, Morel P, Huber O, Meili E, Blum HE, Mentha G. Orthotopic liver transplantation in hemophilia B: a case report. Transpl Int 1995; 8:485-7. [PMID: 8579741 DOI: 10.1007/bf00335602] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Liver transplantation is a treatment modality that is being used with increasing frequency in cases of liver-based metabolic defects. This is a case report of a patient with hemophilia B who was treated since childhood with factor IX replacement for recurrent hemarthroses. Subsequent hepatitis B (HBV) and C (HCV) infection had resulted in the development of chronic active hepatitis, ultimately leading to cirrhosis. Orthotopic liver transplantation performed for endstage liver disease resulted in a rise in factor IX levels from 2% to 83% of normal values within 24 h postoperatively, and levels remained above 90% of normal values after postoperative day 3 without factor IX replacement. To our knowledge, only two cases of hemophilia B treated by orthotopic liver transplantation have been reported. This procedure has, however, only been implemented in cases of terminal liver insufficiency in hemophiliacs.
Collapse
|
157
|
Antonarakis SE, Rossiter JP, Young M, Horst J, de Moerloose P, Sommer SS, Ketterling RP, Kazazian HH, Négrier C, Vinciguerra C, Gitschier J, Goossens M, Girodon E, Ghanem N, Plassa F, Lavergne JM, Vidaud M, Costa JM, Laurian Y, Lin SW, Lin SR, Shen MC, Lillicrap D, Taylor SA, Windsor S, Valleix SV, Nafa K, Sultan Y, Delpech M, Vnencak-Jones CL, Phillips JA, Ljung RC, Koumbarelis E, Gialeraki A, Mandalaki T, Jenkins PV, Collins PW, Pasi KJ, Goodeve A, Peake I, Preston FE, Schwartz M, Scheibel E, Ingerslev J, Cooper DN, Millar DS, Kakkar VV, Giannelli F, Naylor JA, Tizzano EF, Baiget M, Domenech M, Altisent C, Tusell J, Beneyto M, Lorenzo JI, Gaucher C, Mazurier C, Peerlinck K, Matthijs G, Cassiman JJ, Vermylen J, Mori PG, Acquila M, Caprino D, Inaba H. Factor VIII gene inversions in severe hemophilia A: results of an international consortium study. Blood 1995; 86:2206-12. [PMID: 7662970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Twenty-two molecular diagnostic laboratories from 14 countries participated in a consortium study to estimate the impact of Factor VIII gene inversions in severe hemophilia A. A total of 2,093 patients with severe hemophilia A were studied; of those, 740 (35%) had a type 1 (distal) factor VIII inversion, and 140 (7%) showed a type 2 (proximal) inversion. In 25 cases, the molecular analysis showed additional abnormal or polymorphic patterns. Ninety-eight percent of 532 mothers of patients with inversions were carriers of the abnormal factor VIII gene; when only mothers of nonfamilial cases were studied, 9 de novo inversions in maternal germ cells were observed among 225 cases (approximately 1 de novo maternal origin of the inversion in 25 mothers of sporadic cases). When the maternal grandparental origin was examined, the inversions occurred de novo in male germ cells in 69 cases and female germ cells in 1 case. The presence of factor VIII inversions is not a major predisposing factor for the development of factor VIII inhibitors; however, slightly more patients with severe hemophilia A and factor VIII inversions develop inhibitors (130 of 642 [20%]) than patients with severe hemophilia A without inversions (131 of 821 [16%]).
Collapse
|
158
|
Reber G, Vissac AM, de Moerloose P, Bounameaux H, Amiral J. A new, semi-quantitative and individual ELISA for rapid measurement of plasma D-dimer in patients suspected of pulmonary embolism. Blood Coagul Fibrinolysis 1995; 6:460-3. [PMID: 8589214 DOI: 10.1097/00001721-199507000-00014] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The performance of a new membrane ELISA for semi-quantitative determination of plasma D-dimer has been evaluated. Its cut-off is about 500 ng/ml FEU and this single test is completed within 10 min. D-dimer was measured in 301 patients suspected of pulmonary embolism by conventional microplate and membrane ELISA. For the latter, readings were made by eye and some differences were noticed between the readers for reactions in the grey zone. Sensitivity and negative predictive values were similar for the two ELISA (higher than 90%). The 95% confidence intervals of sensitivity and negative predictive values obtained with this membrane ELISA suggest that this new test may be used as a diagnostic tool to exclude the presence of pulmonary embolism.
Collapse
|
159
|
Reber G, Arvieux J, Comby E, Degenne D, de Moerloose P, Sanmarco M, Potron G. Multicenter evaluation of nine commercial kits for the quantitation of anticardiolipin antibodies. The Working Group on Methodologies in Haemostasis from the GEHT (Groupe d'Etudes sur l'Hémostase et la Thrombose). Thromb Haemost 1995; 73:444-52. [PMID: 7667827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The performances of nine commercial kits and an in-house method (HM) for the quantitation of anticardiolipin antibodies (ACA) have been evaluated in a multicenter study. Ninety control and patient samples and six standards from Louisville University were run with kits and with the HM. Marked differences in positivity rate between kits were observed, ranging from 31 to 60% for IgG and 6 to 50% for IgM. Concordance between kits occurred in 59 and 51% of samples for IgG and IgM respectively. Concordance coefficients (kappa) ranged from 0.13 to 0.92. Slopes of regression lines between the declared units of Louisville standards and the units measured from the calibrators of the kits showed great diversity and ranged from 0.159 to 0.931 for IgG and from 0.236 to 0.836 for IgM. The beta 2-glycoprotein I (beta 2-GPI) content of the dilution buffers and the wells supplied with the kits revealed noticeable differences. However samples containing anti-beta 2-GPI antibodies were classified similarly by all but one kit. In contrast the ability to measure samples devoid of anti-beta 2-GPI antibodies differed markedly between the kits. This study shows that differences in positivity rates between the commercial kits may contribute to the differences in ACA prevalence rate found in the literature. The choice of cut-off levels may partly explain the moderate concordance between the kits. In addition some samples behave very differently depending on the kits. In spite of the expression of results in PL units, standardization of ACA assays has not been achieved.
Collapse
|
160
|
Antonarakis SE, Kazazian HH, Gitschier J, Hutter P, de Moerloose P, Morris MA. Molecular etiology of factor VIII deficiency in hemophilia A. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 1995; 386:19-34. [PMID: 8851012 DOI: 10.1007/978-1-4613-0331-2_2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
161
|
Rupin A, Reber G, Bardos P, de Moerloose P. Preferential use of dilutions of single sera than mixture of sera to standardize the quantitation of anticardiolipin antibodies. Thromb Res 1994; 75:465-71. [PMID: 7997984 DOI: 10.1016/0049-3848(94)90261-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The aim of this study was to compare four house standards coming from two University Hospital laboratories with the standards provided by the Antiphospholipid Standardization Laboratory (ASL) in order to quantify anticardiolipin antibodies. Using two different plates and two different buffered protein solutions, slopes from the serial dilutions of each of the four house standards were found comparable. In contrast different slopes were obtained when using the ASL standards which consist of a mixture of sera. Our results indicate that dilutions of single sera are more suitable than mixture of sera when quantification of anticardiolipin antibodies is required.
Collapse
|
162
|
de Moerloose P, Minazio P, Reber G, Perrier A, Bounameaux H. D-dimer determination to exclude pulmonary embolism: a two-step approach using latex assay as a screening tool. Thromb Haemost 1994; 72:89-91. [PMID: 7974382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
D-dimer (DD), when measured by a quantitative enzyme-linked immunosorbent assay (ELISA), is a valuable test to exclude venous thromboembolism (VTE). However, DD ELISA technique is not appropriate for emergency use and the available agglutination latex assays are not sensitive enough to be used as an alternative to rule out the diagnosis of VTE. Latex assays could still be used as screening tests. We tested this hypothesis by comparing DD levels measured by ELISA and latex assays in 334 patients suspected of pulmonary embolism. All but one patient with a positive (DD > or = 500 ng/ml) latex assay had DD levels higher than 500 ng/ml with the ELISA assay. Accordingly, ELISA technique could be restricted to patients with a negative result in latex assay. This two-step approach would have spared about 50% of ELISA in our cohort. In conclusion, our data indicate that a latex test can be used as a first diagnostic step to rule out pulmonary embolism provided a negative result is confirmed by ELISA and the performance of the latex assay used has been assessed properly.
Collapse
|
163
|
Rossiter JP, Young M, Kimberland ML, Hutter P, Ketterling RP, Gitschier J, Horst J, Morris MA, Schaid DJ, de Moerloose P. Factor VIII gene inversions causing severe hemophilia A originate almost exclusively in male germ cells. Hum Mol Genet 1994; 3:1035-9. [PMID: 7981669 DOI: 10.1093/hmg/3.7.1035] [Citation(s) in RCA: 113] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
The factor VIII gene, which is defective in hemophilia A, is located in the last megabase of the long arm of the X chromosome. Inversions due to intrachromosomal homologous recombination between mispaired copies of gene A located within intron 22 of the gene and about 500 kb telomeric to it account for nearly half of all cases of severe hemophilia A. We hypothesized that pairing of Xq with its homolog inhibits the inversion process, and that, therefore, the event originates predominantly in male germ cells. In all 20 informative cases in which the inversion originated in a maternal grandparent, DNA polymorphism analysis determined that it occurred in the male germline. In addition, all but one of 50 mothers of sporadic cases due to an inversion were carriers. Thus, these data support the hypothesis and indicate that factor VIII gene inversions leading to severe hemophilia A occur almost exclusively in male germ cells.
Collapse
|
164
|
Bongard O, Wicky J, Peter R, Simonovska S, Vogel JJ, de Moerloose P, Reber G, Bonameaux H. D-dimer plasma measurement in patients undergoing major hip surgery: use in the prediction and diagnosis of postoperative proximal vein thrombosis. Thromb Res 1994; 74:487-93. [PMID: 8085249 DOI: 10.1016/0049-3848(94)90269-0] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Plasma D-Dimer (DD), a highly sensitive marker of venous thromboembolism, was measured with an ELISA assay preoperatively and on the 12th postoperative day in 173 patients undergoing major hip surgery (78 elective arthroplasties and 95 operations for fractures). Proximal deep venous thrombosis (DVT) was detected by systematic compression venous ultrasonography on the 12th postoperative day in 12 (7%) patients. In one additional case, proximal DVT was diagnosed by venography. Preoperative DD level was significantly higher in patients with fracture than in patients undergoing elective arthroplasty. At a cutoff of 500 micrograms/L as determined by ROC curve analysis, the sensitivity, specificity, positive and negative predictive values of the pre-operative DD concentration for the development of subsequent proximal DVT were 93%, 23%, 36% and 96%, respectively. The diagnostic exclusion value of the DD measurement on the 12th postoperative day was similar but for a cutoff of 2000 micrograms/L. These data suggest that plasma DD measurement might be useful to predict and diagnose proximal DVT following major hip surgery.
Collapse
|
165
|
Perrier A, Bounameaux H, Morabia A, de Moerloose P, Slosman D, Unger PF, Junod A. Contribution of D-dimer plasma measurement and lower-limb venous ultrasound to the diagnosis of pulmonary embolism: a decision analysis model. Am Heart J 1994; 127:624-35. [PMID: 8122612 DOI: 10.1016/0002-8703(94)90673-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study has shown that clinical evaluation and lung scanning may substantiate or exclude pulmonary embolism with reasonable probability in approximately half of the patients in whom it is suspected; for the remainder, pulmonary angiography is considered the gold standard diagnostic test. We performed a decision analysis to assess the potential of two noninvasive tests, D-dimer plasma measurement and lower-limb B-mode venous ultrasound, for reducing the number of pulmonary angiograms necessary to diagnose pulmonary embolism. Our decision model addresses hypothetical patients in the emergency ward with suspected pulmonary embolism and abnormal lung scan results. Results show that D-dimer measurements of less than 500 micrograms/L could be used reliably to exclude pulmonary embolism in patients with an abnormal but not high-probability (inconclusive) lung scan. D-dimer measurements of greater than 500 micrograms/L have no positive predictive value for pulmonary embolism and should be followed by ultrasound, which may replace pulmonary angiography when it discloses deep venous thrombosis. Pulmonary angiography should be performed when ultrasound is negative because of its presumably low sensitivity for deep venous thrombosis in patients with pulmonary embolism. A D-dimer measurement of less than 500 mu/L does not exclude pulmonary embolism in patients with a high clinical suspicion of pulmonary embolism. On the basis of the results of the PIOPED study, we calculated that the combination of D-dimer measurement and ultrasound might reduce the requirement for pulmonary angiography by one third among patients with inconclusive scan results and intermediate clinical probability of pulmonary embolism.
Collapse
|
166
|
De Stefano V, Leone G, Mastrangelo S, Lane DA, Girolami A, de Moerloose P, Sas G, Abildgaard U, Blajchman M, Rodeghiero F. Microheterogeneity of antithrombin III: effect of single amino acid substitutions and relationship with functional abnormalities. Blood Coagul Fibrinolysis 1994; 5:7-15. [PMID: 8180341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Microheterogeneity of antithrombin III (AT-III) was investigated by crossed immunoelectrofocusing (CIEF) on eleven molecular variants. A normal pattern was found in five variants while two different abnormal CIEF patterns were found in the other four and two variants, respectively. Point mutations causing a major pI change (exceeding 4.0) of the amino acid substituted lead to alterations in the overall microheterogeneity. The variants thus substituted share a first type of abnormal CIEF pattern with alterations throughout the pH range, regardless of the location of the mutation (reactive site and adjacent regions or heparin binding region). Minor amino acid pI changes in these regions do not alter the AT-III overall microheterogeneity, whatever the resulting functional defect. However, if the mutation is placed in the region around positions 404 or 429, then even minor changes of the amino acid pI seem able to alter the overall charge, leading to a second type of abnormal CIEF pattern with the main alteration at pH 4.8-4.6. Neuraminidase treatment leads to disappearance of microheterogeneity except for the variants with the Arg393 to Cys substitution. Addition of thrombin induces CIEF modifications specifically related to the functional defect. A normal formation of thrombin-antithrombin complexes induces a shift towards the more acid pH range, whereas in the variants substituted at the reactive site the CIEF pattern is substantially unaffected by thrombin; variants substituted at positions 382-384 show a maximal thrombin-induced increase of the isoforms at pI 4.8-4.6. Therefore mutant antithrombins with different functional abnormalities but sharing a common CIEF pattern were well distinguished.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
167
|
Reber G, Roisin JP, Migaud M, de Moerloose P. Comparison of a platelet neutralization procedure with a hexagonal phase phospholipid neutralization assay as confirmatory tests for the presence of lupus anticoagulants. Thromb Res 1994; 73:131-5. [PMID: 8171412 DOI: 10.1016/0049-3848(94)90088-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
168
|
Bounameaux H, de Moerloose P, Perrier A, Reber G. Plasma measurement of D-dimer as diagnostic aid in suspected venous thromboembolism: an overview. Thromb Haemost 1994; 71:1-6. [PMID: 8165626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
This paper reviews the published experience with plasma measurement of D-dimer (DD), a specific degradation product of crosslinked fibrin, in the diagnostic approach of venous thromboembolism (VTE). Pooling 11 studies (with weighting of the figures according to sample size) with a total of 1337 patients clinically suspected of deep venous thrombosis (DVT) (prevalence of DVT 35%) disclosed an average weighted sensitivity of 96.8% (95% CI: 95.2-98.4) and specificity of 35.2% (95% CI: 32.0-38.4) for the presence of DVT when the ELISA technique was used. In 908 patients suspected of pulmonary embolism (PE) from 9 trials (prevalence of PE 38%), the ELISA technique was associated with a weighted sensitivity of 96.8% (95% CI: 95.0-98.6) and specificity of 45.1% (95% CI: 40.8-49.4) for the disease. Figures obtained with latex assays were definitely lower, precluding their use in the diagnostic approach of VTE. These results show that a low concentration of plasma DD measured by the ELISA technique (usually less than 500 micrograms/l) might be used to rule out VTE in clinically suspected patients. Increased plasma concentrations are of no utility because of the low specificity of this test result. The clinical usefulness of the DD ELISA test should now be assessed in management trials under routine conditions, in the frame of clinical decision-making diagnostic processes. Lastly, the promising data obtained in a small number of asymptomatic, postoperative patients at risk of VTE deserve confirmation before the test can be recommended for initial screening in thrombo-prophylactic trials.
Collapse
|
169
|
Favier R, Nguyen P, de Moerloose P. [For or against preoperative hemostatic evaluation in healthy children?]. Arch Pediatr 1994; 1:11-3. [PMID: 8087212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
170
|
Bounameaux H, de Moerloose P, Perrier A, Reber G. Reply to the Rebuttal of Smith and Kortmann. Thromb Haemost 1994. [DOI: 10.1055/s-0038-1648901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
171
|
Tsakiris DA, de Moerloose P. [Antiphospholipid syndrome: a new clinical entity? Part 2: pathophysiological aspects and treatment possibilities]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT 1993; 123:2183-2190. [PMID: 8272788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Antiphospholipid antibodies are immunoglobulins of the IgG, IgM or rarely IgA class directed against phospholipids or phospholipid-protein complexes of the coagulation cascade. They were first described in patients with systemic lupus erythematosus, but are also frequent in other autoimmune diseases, lymphoproliferative and malignant disorders, some bacterial and viral infections, and after drug exposure. Their mechanism of action is considered multiple, disturbing various natural inhibitory pathways of coagulation. Clinically they have been associated with a thrombotic tendency without a proven direct causal role. Both arterial and venous thromboses, as well as habitual abortion in pregnant women, are reported. A variety of treatment measures have been tried against these associated clinical manifestations.
Collapse
|
172
|
de Moerloose P, Tsakiris DA. [Antiphospholipid syndrome: a new clinical entity? Part 1: antiphospholipid antibodies: specificity and methodological problems]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT 1993; 123:2175-82. [PMID: 8272787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
A new clinical entity, the antiphospholipid syndrome, has recently been described. It is based on the detection of antiphospholipid antibodies either by coagulation tests or by ELISA assay. The precise epitopes towards which these antibodies are directed is a matter of controversy. It is even possible that the name antiphospholipid is inappropriate. The diagnosis of lupus like anticoagulant (LA) detected by coagulation tests requires a three step procedure after appropriate processing of plasma samples. Antiphospholipid antibodies can also be identified by ELISA; this assay is simpler, but there is still a need for standardization. LA and antiphospholipid antibodies identified by ELISA are similar, but not identical; they have similar clinical implications. Due to the heterogeneity of the antibodies and the antigens it is necessary to use a panel of tests to establish or exclude the presence of antiphospholipid antibodies. In the future a better knowledge of antibodies' specificity should help in selecting the most useful test for clinical purposes.
Collapse
|
173
|
Reber G, de Moerloose P. Beta 2-glycoprotein I and antiphospholipid antibodies assays: are we running appropriate sample-blanks? Thromb Haemost 1993; 70:543-4. [PMID: 8259562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
174
|
Christen Y, Minazio P, de Moerloose P. Monitoring of haemostatic parameters in five cases of Amanita phalloides poisoning. Blood Coagul Fibrinolysis 1993; 4:627-30. [PMID: 8218860 DOI: 10.1097/00001721-199308000-00014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The effects of Amanita phalloides poisoning on haemostatic parameters were determined in five members of two families with particular attention to coagulation inhibitors. According to the prothrombin time and factor V level, one patient had severe poisoning, one moderate and the other three had only mild toxicity. The decrease of inhibitors (antithrombin III, proteins C and protein S) was not followed by coagulation activation as assessed by the moderate increase in D-dimers and the absence of a clinically significant coagulopathy. Anti-thrombin III showed little decrease, except in the more severely affected case and protein C paralleled the decrease in factor VII, but to a lesser extent. The decrease in coagulation factors and inhibitors could not be explained by their half-lives alone. Factor V was a better indicator of the recovery of liver synthesis function than other factors. Our observations indicate that monitoring coagulation inhibitors in Amanita poisoning is not more informative than prothrombin time and coagulation factor V, both usually recognized as early prognostic markers of fulminant hepatic failure.
Collapse
|
175
|
Tsakiris DA, Kappos L, Reber G, Marbet GA, Le Floch-Rohr J, Roux E, de Moerloose P. Lack of association between antiphospholipid antibodies and migraine. Thromb Haemost 1993; 69:415-7. [PMID: 8322262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We prospectively studied the prevalence of lupus anticoagulant, anticardiolipin antibodies (aCL) and various haemostatic parameters in 71 patients with migraine and compared the results with a control group of 32 subjects with back pain never having experienced migraine. The patients with migraine were divided into two groups: group I with migraine without (n = 18) and with aura lasting less than 60 min (n = 24) and group II with migraine with prolonged aura or migrainous infarction (complicated migraine, n = 29). The following results were obtained: a) no difference in aCL positivity was noted between migrainous patients and controls and between common migraine and complicated migraine patients and b) no statistically significant difference in haemostatic parameters (except for thrombin-antithrombin III complexes) was found between the two groups of migraine and between aCL positive and negative migrainous patients. These data suggest that anticardiolipin antibodies are not involved in the pathogenesis of migraine complications.
Collapse
|
176
|
Gabay C, Roux-Lombard P, de Moerloose P, Dayer JM, Vischer T, Guerne PA. Absence of correlation between interleukin 6 and C-reactive protein blood levels in systemic lupus erythematosus compared with rheumatoid arthritis. J Rheumatol 1993; 20:815-21. [PMID: 8336307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
To investigate if the low C-reactive protein (CRP) response frequently observed in systemic lupus erythematosus (SLE) is related to an impaired expression of interleukin 6 (IL-6), considered its main inducer, we studied serum IL-6 and CRP levels in 37 patients with SLE and 22 with rheumatoid arthritis (RA). Results show that in contrast to CRP, IL-6 levels are significantly higher in SLE than in RA. A linear regression analysis shows a positive correlation between levels of these 2 molecules in RA but not in SLE. Similarly, levels of fibrinogen, another acute phase protein mainly induced by IL-6, did not correlate with IL-6 in SLE. Our results suggest an impairment of part of the acute phase response to IL-6 that might play a role in the pathogenesis of SLE.
Collapse
|
177
|
Eyster ME, Rabkin CS, Hilgartner MW, Aledort LM, Ragni MV, Sprandio J, White GC, Eichinger S, de Moerloose P, Andes WA. Human immunodeficiency virus-related conditions in children and adults with hemophilia: rates, relationship to CD4 counts, and predictive value. Blood 1993; 81:828-34. [PMID: 8427974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
To further elucidate the natural history of human immunodeficiency virus (HIV) infection, we studied intermediate HIV-related conditions occurring before acquired immunodeficiency syndrome (AIDS) in a prospectively observed multicenter cohort of 738 HIV-infected persons with hemophilia. We analyzed the frequency in adults and children of common HIV-related conditions and the relative risk of AIDS after occurrence of these conditions, controlling for age at seroconversion and the percentage of CD4+ lymphocytes. Thrombocytopenia was the most frequently observed condition with cumulative incidences of 43% +/- 7% in adults and 27% +/- 6% in children and adolescents by 10 years after seroconversion. Oral candidiasis, fever, weight loss, and non-AIDS pneumonia were two to four times more common in adults than children, whereas herpes zoster risk was similar in the two age groups. HIV-related conditions were infrequent during the first 4 years of infection, particularly in children. With the exception of thrombocytopenia, mean CD4 counts were less than 350 cells/microL at the onset of the conditions. The relative hazard of AIDS after oral candidiasis was 18 in children and 3.8 in adults. Relative hazard in adults was also increased after persistent fever (10), weight loss (3.2), and non-AIDS pneumonia (2.2). Herpes zoster and thrombocytopenia were not significantly associated with AIDS in either age group. We conclude that intermediate HIV-related conditions occur more frequently in adults than in children with hemophilia. Persistent fever is the strongest predictor of AIDS in adults, whereas oral candidiasis is the strongest predictor in children. These findings should facilitate the design and conduct of clinical trials as well as the management of HIV-infected children and adults.
Collapse
|
178
|
Raimondi P, Bongard O, de Moerloose P, Reber G, Waldvogel F, Bounameaux H. D-dimer plasma concentration in various clinical conditions: implication for the use of this test in the diagnostic approach of venous thromboembolism. Thromb Res 1993; 69:125-30. [PMID: 8465271 DOI: 10.1016/0049-3848(93)90009-d] [Citation(s) in RCA: 76] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Plasma measurement of D-Dimer (DD) represents a definite aid in the diagnostic approach of outpatients with suspected venous thromboembolism (VTE). However, the high sensitivity (about 95%) of the test which allows to rule out VTE when concentrations are below a given cutoff (500 micrograms/L as measured by the ELISA technique) is counterbalanced by a poor specificity (about 40%). Because the specificity might even be lower in patients who are hospitalized we determined the DD plasma concentration in 255 patients who were consecutively admitted in general internal medicine wards with various pathological conditions. The proportion of patients who had DD levels below the cutoff of 500 micrograms/L was 6% (1/18) in patients with VTE and 22% (52/237) in hospitalized patients without VTE: the figure was 21% in patients with pulmonary infections, 14% in patients with other infections, 11% in patients with neoplastic diseases, 34% in patients with coronary or cerebrovascular disease, 19% in patients with cardiac failure, 69% in patients with rheumatologic disease and in 16% in subjects with miscellaneous clinical conditions. The high rate of elevated plasma DD in hospitalized patients questions the usefulness of this test in the diagnostic approach of VTE in aged patients who present with concomitant disease like infections, neoplasia, cardiac failure and many other pathological conditions, except rheumatologic affections and coronary or cerebrovascular diseases.
Collapse
|
179
|
de Moerloose P, Gavillet O, Salomon D, Minazio P, Reber G. Heparin-related activity in peripheral venous blood after percutaneous application of various glycosaminoglycan containing creams. Blood Coagul Fibrinolysis 1992; 3:827-8. [PMID: 1283344 DOI: 10.1097/00001721-199212000-00040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
180
|
De Benedetti E, Reber G, Miescher PA, de Moerloose P. No increase of beta 2-glycoprotein I levels in patients with antiphospholipid antibodies. Thromb Haemost 1992; 68:624. [PMID: 1455413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
181
|
Bounameaux H, Khabiri E, Huber O, Schneider PA, Didier D, de Moerloose P, Reber G. Value of liquid crystal contact thermography and plasma level of D-dimer for screening of deep venous thrombosis following general abdominal surgery. Thromb Haemost 1992; 67:603-6. [PMID: 1509399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Because the use of radioactive fibrinogen uptake test (FUT) has become questionable both for ethical (risk of virus transmission) and technical (lack of sensitivity) reasons, we investigated the potential value of two alternative methods for screening of asymptomatic deep venous thrombosis following elective digestive surgery: liquid crystal contact thermography (LCCT) and measurement of plasma concentration of D-dimer (DD), as compared with bilateral ascending phlebography. Out of 194 patients, 185 underwent phlebography on the 8th (0-19, median and range) postoperative day. Despite prophylaxis with low-molecular-weight heparin and elastic stockings, DVT was detected on phlebography in 58 legs of 45 patients. Sensitivity of LCCT with respect to the presence of DVT was 55% (n = 184 patients) or 28% (n = 368 legs) with a specificity of 67% and 82%, respectively. These poor performances were obtained despite a good interobserver agreement for the LCCT assessments (overall kappa coefficient of 0.66 between three experts). The most accurate cut-off of DD for discriminating patients with or without DVT was 3,000 micrograms/l, as determined by ROC curve analysis. Sensitivity of a DD level of more than 3,000 micrograms/l for the presence of phlebographically documented DVT on the 8th postoperative day was 89% for a specificity of 48%. Thus, LCCT cannot be used for screening of postoperative, mainly asymptomatic DVT following general surgery. On the other hand, measurement of plasma DD may be useful for initial screening, a negative result (level less than 3,000 micrograms/l) allowing to exclude DVT (negative predictive value of 93%) and a positive result (positive predictive value of 35%) requiring confirmation by phlebography.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
182
|
Bongard O, Reber G, Bounameaux H, de Moerloose P. Anticardiolipin antibodies in acute venous thromboembolism. Thromb Haemost 1992; 67:724. [PMID: 1509416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
183
|
Reber G, Stoermann C, de Moerloose P, Ruedin P, Leski M. Hemostatic disturbances induced by two hollow-fiber hemodialysis membranes. Int J Artif Organs 1992; 15:269-76. [PMID: 1601510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The effects on hemostasis of two high-flux membranes in hollow-fiber configuration, polyamide (PAM) and polyacrylonitrile (AN69), were analyzed in a cross-over study involving ten chronic hemodialyzed patients. Blood samples were obtained at arterial and venous sites of the extracorporeal circuit before dialysis and at 15, 30 and 180 min. Primary hemostasis: PAM induced an early significant drop in platelet counts, but at 180 min there was no longer any difference between membranes. Beta-thromboglobulin release by PAM was significantly higher at all time points. Coagulation: thrombin-antithrombin III complexes (TAT) and fibrinopeptide A increased significantly, the highest values being found with AN69. With both membranes the arterio-venous differences in TAT levels were negative throughout the sessions. Fibrinolysis: no significant differences were observed. In conclusion, both membranes induced hemostatic changes. Although these two hollow-fiber dialyzers look relatively similar, the changes observed were different, polyamide acting mainly on primary hemostasis and polyacrylonitrile on coagulation.
Collapse
|
184
|
De Benedetti E, Nicod L, Reber G, Vifian C, de Moerloose P. Procoagulant and fibrinolytic activities in bronchoalveolar fluid of HIV-positive and HIV-negative patients. Eur Respir J 1992; 5:411-7. [PMID: 1563500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Imbalance between intra-alveolar procoagulant activity (PCA) and fibrinolytic activity may lead to fibrin deposition, as described in several pneumopathies, and may eventually contribute to fibrotic changes as observed in Pneumocystis carinii pneumonia (PCP). The aim of our study was to compare these activities in bronchoalveolar lavages of human immunodeficiency virus (HIV)-positive and HIV-negative patients. The material comprised: a) controls (n = 7); b) HIV-positive patients subdivided into PCP (n = 11), bacterial pneumonia (n = 8) and other pneumopathies (n = 22); and c) HIV-negative patients with bacterial pneumonia (n = 8). PCA was significantly increased (p less than 0.05) in all patient groups compared to controls. The urokinase-type plasminogen activator (u-PA) antigen levels were highest during bacterial pneumonia. Regardless of the HIV status, in bacterial pneumonia there was a marked elevation of plasminogen activator inhibitor antigens with little residual fibrinolytic activity. In contrast, the fibrinolytic activity was not decreased in PCP. D-dimer were elevated during PCP compared to controls; the highest levels were found in HIV-negative bacterial pneumonia. These data indicate that transient fibrotic changes seen in PCP may be favoured by increased PCA, but not by a depressed fibrinolytic activity. In bacterial pneumonia PCA is increased and fibrinolysis decreased independently of the HIV status.
Collapse
|
185
|
De Benedetti E, Nicod L, Reber G, Vifian C, de Moerloose P. Procoagulant and fibrinolytic activities in bronchoalveolar fluid of HIV-positive and HIV-negative patients. Eur Respir J 1992. [DOI: 10.1183/09031936.93.05040411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Imbalance between intra-alveolar procoagulant activity (PCA) and fibrinolytic activity may lead to fibrin deposition, as described in several pneumopathies, and may eventually contribute to fibrotic changes as observed in Pneumocystis carinii pneumonia (PCP). The aim of our study was to compare these activities in bronchoalveolar lavages of human immunodeficiency virus (HIV)-positive and HIV-negative patients. The material comprised: a) controls (n = 7); b) HIV-positive patients subdivided into PCP (n = 11), bacterial pneumonia (n = 8) and other pneumopathies (n = 22); and c) HIV-negative patients with bacterial pneumonia (n = 8). PCA was significantly increased (p less than 0.05) in all patient groups compared to controls. The urokinase-type plasminogen activator (u-PA) antigen levels were highest during bacterial pneumonia. Regardless of the HIV status, in bacterial pneumonia there was a marked elevation of plasminogen activator inhibitor antigens with little residual fibrinolytic activity. In contrast, the fibrinolytic activity was not decreased in PCP. D-dimer were elevated during PCP compared to controls; the highest levels were found in HIV-negative bacterial pneumonia. These data indicate that transient fibrotic changes seen in PCP may be favoured by increased PCA, but not by a depressed fibrinolytic activity. In bacterial pneumonia PCA is increased and fibrinolysis decreased independently of the HIV status.
Collapse
|
186
|
de Moerloose P, De Benedetti E, Nicod L, Vifian C, Reber G. Procoagulant activity in bronchoalveolar fluids: no relationship with tissue factor pathway inhibitor activity. Thromb Res 1992; 65:507-18. [PMID: 1615494 DOI: 10.1016/0049-3848(92)90202-l] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Abnormalities in local coagulation may explain alveolar fibrin deposition which often accompanies human lung injuries. The purpose of this study was to investigate the generation of procoagulant activity (PCA) and tissue factor pathway inhibitor (TFPI) in selected bronchoalveolar lavage fluids (BAL) from controls (n = 7) and from patients with interstitial lung diseases (n = 9), Pneumocystis carinii (PCP) pneumonia (n = 11) and bacterial pneumonia (n = 8). As compared with controls a significant increase of PCA was observed in the three groups with lung diseases. PCA in BAL from patients with untreated interstitial lung diseases (PC Units mean of 162 +/- 48) was significantly higher than PCA of treated patients (PC Units 36 +/- 10; p less than 0.05). Increases of PCA paralleled protein levels in BAL and the protein/albumin ratios were comparable in the four groups. TFPI was significantly increased in PCP (p less than 0.02) and bacterial pneumonia (p less than 0.03), but only marginally increased in interstitial lung diseases when compared with controls. No correlation was found between TFPI and PCA in any of the four groups. These data indicate that increased procoagulant activity observed in various lung diseases is not counterbalanced by TFPI.
Collapse
|
187
|
Bounameaux H, Righetti A, de Moerloose P, Bongard O, Reber G. Effects of exercise test on plasma markers of an activation of coagulation and/or fibrinolysis in patients with symptomatic or silent myocardial ischemia. Thromb Res 1992; 65:27-32. [PMID: 1604440 DOI: 10.1016/0049-3848(92)90222-v] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
It has been suggested that unstable angina at rest, like acute myocardial infarction, might be associated with a thrombotic process. In order to study the hypothesis that myocardial ischemia during exercise could also be associated with an activation of blood coagulation and/or fibrinolysis, we investigated the presence of plasma markers of a prethrombotic or thrombotic state (thrombin-antithrombin III complexes TAT, prothrombin fragment F1 + 2, and D-dimers DD) in 100 consecutive patients with confirmed or suspected coronary artery disease during ergometric test with myocardial thallium-201 scintigraphy. Symptoms and scintigrams allowed to define three groups of patients: those showing no ischemia (n = 79) and those with symptomatic (n = 8) or silent myocardial ischemia (n = 13). Before exercise, DD and TAT levels were not significantly different among the three groups. On the other hand, the F1 + 2 levels were slightly albeit significantly higher in the patients without ischemia than in the patients with symptomatic or silent ischemia. After exercise, no significant difference was found between the three groups. Exercise induced a significant and parallel increase in both the TAT and the F1 + 2 levels (but not of the DD levels) in the three groups. Thus, our study does not support the hypothesis that myocardial ischemia, silent or symptomatic, is associated with an activation of plasma coagulation and fibrinolysis that can be distinguished from the exercise-induced thrombin generation.
Collapse
|
188
|
Vogel JJ, Reber G, de Moerloose P. Laboratory and clinical features in systemic lupus erythematosus patients with or without anticardiolipin antibodies. Thromb Res 1991; 62:545-56. [PMID: 1910214 DOI: 10.1016/0049-3848(91)90027-t] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The purpose of this study was to investigate whether the presence of anticardiolipin antibodies (aCL) in systemic lupus erythematosus (SLE) patients was associated with particular laboratory or clinical features. Anticardiolipin antibodies were determined in 63 unselected SLE patients: 32 (50.8%) were found to be aCL positive and this positivity was significantly associated with the presence of lupus anticoagulant (p less than 0.003) and false positive VDRL reaction (p less than 0.001), but not with other haematological or biological markers. Thrombin-antithrombin III (TAT) complexes were found to be increased with disease activity, but no relationship was found between TAT complexes and the presence or absence of aCL. In this study a statistically significant association was found between aCL positivity and arterial thromboembolic events, but not with venous thrombotic complications. In summary half of SLE patients had aCL and the presence of these antibodies was associated with other antiphospholipid antibodies and with arterial thromboembolic events.
Collapse
|
189
|
de Moerloose P, Bounameaux H. [Is the biological diagnosis of thromboembolic venous disease possible?]. LA REVUE DU PRATICIEN 1991; 41:999-1001. [PMID: 2063114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
190
|
Bounameaux H, Cirafici P, de Moerloose P, Schneider PA, Slosman D, Reber G, Unger PF. Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism. Lancet 1991; 337:196-200. [PMID: 1670841 DOI: 10.1016/0140-6736(91)92158-x] [Citation(s) in RCA: 202] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The potential of plasma measurement of D-dimer (DD), a specific derivative of crosslinked fibrin, for diagnosis or exclusion of pulmonary embolism was investigated in a prospective series of 171 consecutive patients who attended an emergency department with suspected pulmonary embolism. The diagnosis was made or excluded by means of a clinical decision-making process which included clinical evaluation, ventilation-perfusion (VQ) lung scan, and, as indicated, pulmonary angiography, venography, or non-invasive examination of the leg veins. Pulmonary embolism was diagnosed by this process in 55 (32%) of 170 patients with sufficient data. All but 1 of these 55 patients had a DD concentration of 500 micrograms/l or above. The sensitivity and specificity of this cutoff concentration for the presence of pulmonary embolism were 98% and 39%, respectively, which give positive and negative predictive values of 44% and 98%. Among the 115 patients (68%) who had inconclusive VQ scans, 31 were diagnosed as having pulmonary embolism. 29 of the remaining 84 patients without pulmonary embolism had DD concentrations below 500 micrograms/l, which means that further diagnostic procedures could have been avoided in a quarter of the patients with inconclusive VQ scans. The sensitivity of the plasma measurement of DD remained high even 3 and 7 days after presentation (96% and 93%). Plasma measurement of DD therefore has a definite place in the diagnostic procedure for suspected acute pulmonary embolism in attenders at emergency departments: a concentration below 500 micrograms/l rules out the diagnosis.
Collapse
|
191
|
Gandrille S, Aiach M, Lane DA, Vidaud D, Molho-Sabatier P, Caso R, de Moerloose P, Fiessinger JN, Clauser E. Important role of arginine 129 in heparin-binding site of antithrombin III. Identification of a novel mutation arginine 129 to glutamine. J Biol Chem 1990; 265:18997-9001. [PMID: 2229057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
An hereditary abnormal antithrombin III (ATIII Geneva) with defective heparin cofactor activity was characterized by DNA single strand amplification and subsequent direct sequencing. ATIII Geneva was found to have a G to A transition in Exon IIIa leading to an Arg-129 to Gln mutation. This amino acid is part of the ATIII region comprising residues 114-154, which contains the highest proportion of basic residues (Arg or Lys), and is known from chemical modification studies to be involved in heparin binding. The variant protein did not bind heparin-Sepharose and was isolated from the propositus plasma by immunoaffinity chromatography. High affinity (for ATIII) heparin had only a minimal effect on thrombin and activated factor X inhibition by the purified abnormal ATIII. Taken together, these results demonstrate an important role for Arg-129 in the binding and interaction of ATIII with heparin of high affinity. We propose that a cooperation between Lys-125, Arg-129, Lys-136, and Arg-47 exposed at the surface of the inhibitor allows the binding of the essential pentasaccharide domain of heparin which is specific for the ATIII interaction.
Collapse
|
192
|
Gandrille S, Aiach M, Lane D, Vidaud D, Molho-Sabatier P, Caso R, de Moerloose P, Fiessinger J, Clauser E. Important role of arginine 129 in heparin-binding site of antithrombin III. Identification of a novel mutation arginine 129 to glutamine. J Biol Chem 1990. [DOI: 10.1016/s0021-9258(17)30614-2] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
193
|
Bounameaux H, Schneider PA, Slosman D, de Moerloose P, Reber G. Plasma D-dimer in suspected pulmonary embolism: a comparison with pulmonary angiography and ventilation--perfusion scintigraphy. Blood Coagul Fibrinolysis 1990; 1:577-9. [PMID: 2133237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The diagnosis of pulmonary embolism remains a difficult issue. In a previous study of patients submitted to ventilation--perfusion (V-P) scintigraphy we suggested that measurement of D-dimer might be of value for ruling out the diagnosis of pulmonary embolism if the plasma level was less than 500 micrograms/l (ELISA). In the present paper, this cut-off was validated in a consecutive series of 21 patients who were submitted to pulmonary angiography. Sensitivity and specificity were 100% and 36%, respectively. When these data were pooled with the results obtained following V-P scintigraphy (total number of patients = 67), sensitivity, specificity, and positive and negative predictive values were 100%, 70%, 59% and 100%, respectively. It is therefore worthwhile to further evaluate the value of the plasma measurement of D-dimers, especially in patients with inconclusive lung scintigraphy.
Collapse
|
194
|
Furlan M, Bögli C, Hofer A, Bouvier CA, de Moerloose P. Fibrinogen Geneva, a new case of A alpha 16 Arg----Cys dysfibrinogenaemia. Blood Coagul Fibrinolysis 1990; 1:139-43. [PMID: 2130925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A new congenital variant of fibrinogen, from which only half the normal amount of fibrinopeptide A can be released by thrombin, was found in three members of a family having no major bleeding or thrombotic tendency. Following carboxamidomethylation of the reduced fibrinogen chains, an abnormal peptide was cleaved by thrombin from the amino terminus of the A alpha-chain (A* alpha 1-19) and isolated by reversed phase high-performance liquid chromatography. Amino acid analysis indicated the presence of carboxymethyl cysteine in this A alpha-chain fragment which in normal fibrinogen is devoid of cysteine. We conclude that fibrinogen Geneva is another fibrinogen variant with the substitution A alpha 16 Arg----Cys.
Collapse
|
195
|
Naimi N, Plancherel C, Bosser C, Jeannet M, de Moerloose P. Anticardiolipin antibodies in HIV-negative and HIV-positive haemophiliacs. Blood Coagul Fibrinolysis 1990; 1:5-8. [PMID: 2102789 DOI: 10.1097/00001721-199003000-00002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Anticardiolipin antibodies (ACA) were determined in 72 heavily transfused haemophiliacs, 43 HIV-positive and 29 HIV-negative. The presence of ACA was detected in 10 patients, all of them infected by HIV: 8 in CDC II, 1 in CDC III and 1 in CDC IV. The comparison with alterations of other laboratory markers in HIV-infected patients did not show any statistically significant difference between ACA-negative and -positive patients. In summary, ACA were found only in HIV-infected haemophiliacs. In this subgroup of patients the presence of ACA was not associated with progression to AIDS.
Collapse
|
196
|
Reber G, Tremblet C, Bernard C, Mermillod B, de Moerloose P. Anticardiolipin antibodies and thrombosis: buffer's influence on the detection and quantitation of anticardiolipin antibody measured by ELISA. Thromb Res 1990; 57:215-26. [PMID: 2315886 DOI: 10.1016/0049-3848(90)90321-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The influence of adult bovine serum (ABS) and fetal calf serum (FCS) on IgG anticardiolipin antibodies (ACA) levels measured by ELISA has been investigated. In control subjects the frequency of the optical density (O.D.) distribution was found to be non-gaussian. The O.D. of the 97th percentile was similar with both buffers, although the distribution of O.D. was statistically different (P less than 0.004). The slope of the dilution curves of two house standards as well as the curves obtained with reference standards were found to be very different depending on the buffer. In 55 consecutive patients with thrombotic events, recurrent fetal loss or auto-immune disorders, ACA positivity was also dependent on the way to express the data and the choice of the buffer: when O.D. values were read with their respective standard curves, IgG ACA positivity was 98% with FCS and 20% with ABS (P less than 0.001), but when the 97th percentile O.D. was considered, 40% were positive with FCS and 51% with ABS (n.s.). Furthermore 10 patients were found to be negative with FCS and positive with ABS and 4 others showed the inverse picture. Levels of positivity were also dependent on the buffer. These differences arise from the solution used to dilute the sera and not of that to block the plates. These methodological problems may explain some conflicting data found in the literature about the prevalence of ACA positivity.
Collapse
|
197
|
Bernard C, de Moerloose P, Tremblet C, Reber G, Didierjean L. Biological true and false serological tests for syphilis: their relationship with anticardiolipin antibodies. DERMATOLOGICA 1990; 180:151-3. [PMID: 2340925 DOI: 10.1159/000248016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Anticardiolipin antibodies (ACA) were determined by an ELISA assay in 142 VDRL-positive patients who were classified in two groups: group I consisted of 77 patients with syphilis and group II of 65 patients with biological false-positive reaction in the standard test for syphilis. In group I 10% had ACA versus 52% in group II (p less than 0.0001). Isotype distribution in group II showed a predominance of IgG. These results suggest that antiphospholipid antibodies in VDRL and ACA tests have different specificities.
Collapse
|
198
|
Bernard C, Ody B, de Moerloose P. The non-ionic contrast media: thrombosis or haemorrhage? Eur J Radiol 1989; 9:131-2. [PMID: 2680486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
199
|
Bounameaux H, Slosman D, de Moerloose P, Reber G. Laboratory diagnosis of pulmonary embolism: value of increased levels of plasma D-dimer and thrombin--antithrombin III complexes. Biomed Pharmacother 1989; 43:385-8. [PMID: 2676005 DOI: 10.1016/0753-3322(89)90066-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Plasma D-dimer (DD) and thrombin--antithrombin III complex (TAT) were measured with ELISAs in 99 patients investigated by 102 ventilation--perfusion lung scintigraphy because of suspected pulmonary embolism. High-probability lung scan was associated with increased DD (more than 500 ng/ml) and TAT (more than 4.1 ng/ml) levels (sensitivity of 100 and 70%, respectively). The corresponding figures of specificity were 81 and 42%. In the 56 patients with low-probability or indeterminate probability scans, 31 (55%) had DD concentrations of less than 500 ng/ml. These preliminary data suggest that a plasma DD concentration of less than 500 ng/ml might rule out the diagnosis of pulmonary embolism in suspected patients with an inconclusive lung scanning.
Collapse
|
200
|
Bounameaux H, Schneider PA, Reber G, de Moerloose P, Krahenbuhl B. Measurement of plasma D-dimer for diagnosis of deep venous thrombosis. Am J Clin Pathol 1989; 91:82-5. [PMID: 2642640 DOI: 10.1093/ajcp/91.1.82] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Venography was performed on fifty-six patients suspected of having deep venous thrombosis (DVT) of the legs. The accuracy of the D-dimer measurement in plasma using two latex tests and an enzyme-linked immunosorbent assay (ELISA) was compared with that of usual determination of total fibrin(ogen) degradation products (FDPs) in serum with respect to the presence of DVT. The three D-dimer tests were clearly superior to the FDP assay, but only the ELISA could accurately rule out the diagnosis of DVT with a predictive value of 100% when plasma D-dimer level was less than 200 micrograms/L. However, this test cannot be used for positive diagnosis (false positive rate of 69%). Thus, plasma D-dimer measurement with ELISA allows identification of patients in whom further investigation by means of more specific tests (venography or plethysmography) is indicated in order to establish the diagnosis of DVT. In contrast to this, sensitivity of the two latex tests studied was low (60 and 76%, respectively), which makes them unsuitable for emergency screening. In addition, the potential of D-dimer dosage for diagnosis of DVT in hospitalized patients is hampered by the presence of associated conditions that are responsible for elevated plasma levels in most cases.
Collapse
|