76
|
Castillo-Macías A, Arreola-Martínez JE, Loya-García D, Valdez-García JE. Prevalence and clinical characteristics of neurotrophic keratopathy in hispanic population in northeastern Mexico. Int Ophthalmol 2023:10.1007/s10792-023-02726-x. [PMID: 37140835 PMCID: PMC10400685 DOI: 10.1007/s10792-023-02726-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 04/14/2023] [Indexed: 05/05/2023]
Abstract
PURPOSE To evaluate the prevalence and clinical characteristics of neurotrophic keratopathy (NK) in northeastern Mexico. METHODS Retrospective cross-sectional study in which NK patients admitted to our ophthalmology clinic between 2015 and 2021 were consecutively enrolled. Data regarding demographics, clinical characteristics, and comorbidities were collected at the time diagnosis of NK was made. RESULTS In the period from 2015 to 2021, a total of 74,056 patients were treated and of these 42 had a diagnosis of neurotrophic keratitis. The prevalence found was 5.67 [CI95 3.95-7.38] in 10,000 cases. The mean age observed was 59 ± 17.21 years occurring more frequently in males in 59% and with corneal epithelial defects in 66.7%. The most frequent antecedents were the use of topical medications in 90%, the presence of diabetes mellitus 2 in 40.5% and systemic arterial hypertension in 26.2%. A higher proportion of male patients with corneal alterations and a higher proportion of female patients with corneal ulcerations and/or perforation were observed. CONCLUSION Neurotrophic keratitis is an underdiagnosed disease with a broad clinical spectrum. The antecedents that were contracted corroborate what was reported in the literature as risk factors. The prevalence of the disease in this geographical area was not reported, so it is expected to increase over time when searching for it intentionally.
Collapse
|
77
|
Guemes-Villahoz N, Burgos-Blasco B, Echevarria-Torres PL, Vidal-Villegas B, Rodriguez de la Peña A, Diaz-Valle D, Fernández-Vigo JI, Sánchez-Ramón S, Garcia-Feijoo J. [Detection of anti-SARS-CoV-2 antibodies in tears: Ocular surface immunity to COVID-19]. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023:S0365-6691(23)00091-6. [PMID: 37360534 PMCID: PMC10150186 DOI: 10.1016/j.oftal.2023.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/29/2023] [Indexed: 06/28/2023]
Abstract
Purpose To evaluate the presence of SARS-CoV-2 specific IgA and IgG antibodies in tears of unvaccinated and anti-COVID-19 vaccinated subjects with previous history of SARS-CoV-2 infection. To compare results in tears with those in saliva and serum and correlate with clinical data and vaccination regimens. Methods Cross-sectional study including subjects with a previous history of SARS-CoV-2 infection, both unvaccinated and vaccinated against COVID-19. Three samples were collected: tears, saliva and serum. IgA and IgG antibodies against S-1 protein of SARS-CoV-2 were analyzed with a semi-quantitative ELISA. Results Thirty subjects, mean age 36.4 ± 10, males 13/30 (43.3%) with history of mild SARS-CoV-2 infection were included. 13/30 (43.3%) subjects had received a 2-dose regimen and 13/30 (43.3%) a 3-dose regimen of anti-COVID-19 vaccine, 4/30 (13.3%) subjects were unvaccinated. All the participants with full anti-COVID-19 vaccination (2-or 3-doses) presented detectable anti-S1 specific IgA in all 3 biofluids, tears, saliva and serum. Among unvaccinated subjects, specific IgA was detected in 3/4 subjects in tears and saliva, whereas IgG was not detected. Considering IgA and IgG antibodies titers, no differences were observed between the 2- and 3-dose vaccination regimen. Conclusions SARS-CoV-2-specific IgA and IgG antibodies were detected in tears after mild COVID-19, highlighting the role of the ocular surface as a first line of defense against infection. Most naturally infected unvaccinated individuals exhibit long-term specific IgA in tears and saliva. Hybrid immunization (natural infection plus vaccination) appears to enhance mucosal and systemic IgG responses. However, no differences were observed between the 2- and 3-dose vaccination schedule.
Collapse
|
78
|
Downie LE, Britten-Jones AC, Hogg RE, Jalbert I, Li T, Lingham G, Liu SH, Qureshi R, Saldanha IJ, Singh S, Craig JP. TFOS Lifestyle - Evidence quality report: Advancing the evaluation and synthesis of research evidence. Ocul Surf 2023; 28:200-212. [PMID: 37054912 DOI: 10.1016/j.jtos.2023.04.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 04/15/2023]
Abstract
Evidence-based practice is a dominant paradigm in healthcare that emphasizes the importance of ensuring the translation of the best available, relevant research evidence into practice. An Evidence Quality Subcommittee was established to provide specialized methodological support and expertise to promote rigorous and evidence-based approaches for the Tear Film and Ocular Surface Society (TFOS) Lifestyle Epidemic reports. The present report describes the purpose, scope, and activity of the Evidence Quality Subcommittee in the undertaking of high-quality narrative-style literature reviews, and leading prospectively registered, reliable systematic reviews of high priority research questions, using standardized methods for each topic area report. Identification of predominantly low or very low certainty evidence across the eight systematic reviews highlights a need for further research to define the efficacy and/or safety of specific lifestyle interventions on the ocular surface, and to clarify relationships between certain lifestyle factors and ocular surface disease. To support the citation of reliable systematic review evidence in the narrative review sections of each report, the Evidence Quality Subcommittee curated topic-specific systematic review databases and relevant systematic reviews underwent standardized reliability assessment. Inconsistent methodological rigor was noted in the published systematic review literature, emphasizing the importance of internal validity assessment. Based on the experience of implementing the Evidence Quality Subcommittee, this report makes suggestions for incorporation of such initiatives in future international taskforces and working groups. Content areas broadly relevant to the activity of the Evidence Quality Subcommittee, including the critical appraisal of research, clinical evidence hierarchies (levels of evidence), and risk of bias assessment, are also outlined.
Collapse
|
79
|
Shah S, Dutta D, Barua A, Hanneken L, Naroo SA. The effect of non-ablative thermomechanical skin treatment (Tixel®) on dry eye disease: A prospective two centre open-label trial. Cont Lens Anterior Eye 2023; 46:101811. [PMID: 36635105 DOI: 10.1016/j.clae.2022.101811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 12/16/2022] [Accepted: 12/30/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE To determine the effects of a thermo-mechanical action-based peri-orbital fractional skin treatment (Tixel®) on dry eye disease. METHODS This prospective, controlled, open labelled study was conducted at two study centres: Midland Eye, Solihull, UK, and Vallmedic Vision, Andorra. Participants were screened at the baseline visit (visit-1), received three Tixel® treatments at 2-weeks intervals including further assessment (visits 2, 3 and 4). Participants were followed up for three months post-treatment (visit 5). Vision, intraocular pressure (IOP), dry eye symptomatology were assessed, including the Ocular Surface Disease Index (OSDI) questionnaire, non-invasive tear break-up time (NIBUT) and tear osmolarity as well as detailed ophthalmic assessments. RESULTS Seventy-four participants (41 in Birmingham and 33 in Andorra) with periorbital wrinkles and moderate to severe dry eye disease (DED) were enrolled. The mean age was 59.3 ± 13.3 years and 57 were females. No adverse events, no change in vision (p = 0.310) or IOP (p = 0.419) were observed. Tixel treatment was associated with clinically and statistically significant improvement in the DED symptoms, which was supported by a reduction of 21.40 ± 15.08 (P < 0.001) of the OSDI index. Non-invasive tear break-up time improved by 2.10 ± 0.91 s (p < 0.001) in the Birmingham cohort and 6.60 ± 2.13 s (p < 0.001) in the Andorra cohort. Tear osmolarity reduced from 299.8 ± 13.3 mOsm/L to 298.8 ± 15.6 mOsm/L following the Tixel treatment (p = 0.271). CONCLUSIONS Thermo-mechanical action-based peri-orbital fractional skin treatment Tixel® could be an attractive, safe and effective treatment for DED. This treatment is associated with high clinical and statistically significant improvement in DED signs and symptoms with no adverse events.
Collapse
|
80
|
Abdelmotaal H, Hazarbasanov R, Taneri S, Al-Timemy A, Lavric A, Takahashi H, Yousefi S. Detecting dry eye from ocular surface videos based on deep learning. Ocul Surf 2023; 28:90-98. [PMID: 36708879 DOI: 10.1016/j.jtos.2023.01.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 09/28/2022] [Accepted: 01/16/2023] [Indexed: 01/27/2023]
Abstract
OBJECTIVE To assess the performance of convolutional neural networks (CNNs) for automated diagnosis of dry eye (DE) in patients undergoing video keratoscopy based on single ocular surface video frames. DESIGN This retrospective cohort study included 244 ocular surface videos from 244 eyes of 244 subjects based on corneal topography. A total of 116 eyes were normal while 128 eyes had DE based on clinical evaluations. METHODS We developed a deep transfer learning model to directly identify DE from ocular surface videos. We evaluated the performance of the CNN model based on objective accuracy metrics. We assessed the clinical relevance of the findings by evaluating class activations maps. MAIN OUTCOME MEASURE Area under the receiver operating characteristics curve (AUC), accuracy, specificity, and sensitivity. RESULTS The AUC of the model for discriminating normal eyes from eyes with DE was 0.98. Network activation maps suggested that the lower paracentral cornea was the most important region for detection of DE by the CNN model. CONCLUSIONS Deep transfer learning achieved a high diagnostic accuracy in detecting DE based on non-invasive ocular surface videos at levels that may prove useful in clinical practice.
Collapse
|
81
|
Leis ML. An Update on the Ocular Surface Bacterial Microbiota in Small Animals. Vet Clin North Am Small Anim Pract 2023; 53:299-318. [PMID: 36813387 DOI: 10.1016/j.cvsm.2022.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
High-throughput sequencing (HTS) techniques have revolutionized the way we understand microbial communities in both research and clinical settings and are bringing new insights into what constitutes a healthy ocular surface (and a diseased one). As more diagnostic laboratories incorporate HTS into their technique repertoire, practitioners can expect this technology to become increasingly accessible for clinical practice, potentially becoming the new standard. However, particularly regarding ophthalmic microbiota, considerable research remains to render HTS accessible and applicable.
Collapse
|
82
|
Caycedo Lozano AR, Arias Ortiz WA, Martín V, Ramírez S, Medina Siervo CA. Analysis of diagnostic tests in patients with dry eye and hypothyroidism: an observational study. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023; 98:163-169. [PMID: 36114138 DOI: 10.1016/j.oftale.2022.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 03/13/2022] [Indexed: 10/14/2022]
Abstract
PURPOSE Colombia is a country with a high prevalence of hypothyroidism, approximately 18.5% compared to the rest of Latin American countries, which is estimated at 10%. That is why in the ophthalmology consultation we find a large proportion of patients with this disease and who also present symptoms of dry eye. When conducting a search in the medical literature, most publications refer to the clinical presentation of dry eye in hyperthyroidism, which is why the main objective of this study is to evaluate tear function tests in the diagnosis of dry eye in patients with hypothyroidism. METHODS This is an observational, cross-sectional study carried out in the period between May and December 2019 in the ocular surface unit of the Ophthalmic Technology Center (CTO) in Bogotá. The tests of: OSDI test (Ocular Surface Disease Index), Schirmer type I, tear meniscus height, NiBUT, Osmolarity, Ferning test, Lisamine Green test of 59 patients with Dry Eye Disease (DED) and history of hypothyroidism. RESULTS Schirmer type I and NiBUT tests were the parameters that presented the highest percentage of severity, while lissamine green staining and meniscometry showed a tendency to normality. CONCLUSIONS The population of this study presents a mixed type dry eye without epithelial cell damage.
Collapse
|
83
|
Amatu JB, Baudouin C, Trinh L, Labbé A, Buffault J. [Corneal epithelial biomechanics: Resistance to stress and role in healing and remodeling]. J Fr Ophtalmol 2023; 46:287-299. [PMID: 36759249 DOI: 10.1016/j.jfo.2022.09.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 09/29/2022] [Accepted: 09/29/2022] [Indexed: 02/10/2023]
Abstract
The corneal epithelium is one of the first tissue barriers of the eye against the environment. In recent years, many studies provided better knowledge of its healing, its behavior and its essential role in the optical system of the eye. At the crossroads of basic science and clinical medicine, the study of the mechanical stresses applied to the cornea makes it possible to learn the behavior of epithelial cells and better understand ocular surface disease. We describe herein the current knowledge about the adhesion systems of the corneal epithelium and their resistance to mechanical stress. We will also describe the involvement of these mechanisms in corneal healing and their role in epithelial dynamics. Adhesion molecules of the epithelial cells, especially hemidesmosomes, allow the tissue cohesion required to maintain the integrity of the corneal epithelium against the shearing forces of the eyelids as well as external forces. Their regeneration after a corneal injury is mandatory for the restoration of a healthy epithelium. Mechanotransduction plays a significant role in regulating epithelial cell behavior, and the study of the epithelium's response to mechanical forces helps to better understand the evolution of epithelial profiles after refractive surgery. A better understanding of corneal epithelial biomechanics could also help improve future therapies, particularly in the field of tissue engineering.
Collapse
|
84
|
Zhou J, Fan L, Lin H, Zheng D, Yang L, Zhuo D, Zhuoma J, Li H, Zhang S, Ruan Z. Size-specific particulate matter and outpatient visits for allergic conjunctivitis in children: a time-stratified case-crossover study in Guangzhou, China. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:33949-33959. [PMID: 36502478 DOI: 10.1007/s11356-022-24564-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 11/30/2022] [Indexed: 06/17/2023]
Abstract
This time-stratified case-crossover study aims to quantify the risk of allergic conjunctivitis (AC) associated with short-term exposure to PMs (i.e., PM1, PM2.5, PMc, and PM10) among children in Guangzhou, China. We collected data on children's daily AC outpatient visits from the Guangzhou Women and Children Medical Center during February 20, 2016 to December 31, 2018, and also extracted air pollution and meteorological data in the same time frame. We used conditional logistic regression model to estimate the associations between PMs and AC outpatient visits, and conducted subgroup analyses stratified by sex, age, and season. During the study period, we recorded 39,330 children's outpatient visits for AC, including 27,638 boys and 11,692 girls. The associations between PMs and AC were general linear with no clear threshold, which were largest at the current days but remained positive for lag 1 to 3 days. For every 10 μg/m3 increase in daily PM1, PM2.5, PMc, and PM10 concentrations, the estimated risks of AC outpatient visits at the current days increased by 2.5% (OR = 1.025, 95% CI: 1.011-1.039), 1.8% (OR = 1.018, 95% CI: 1.009-1.027), 2.1% (OR = 1.021, 95% CI: 1.004-1.039), and 1.3% (OR = 1.013, 95% CI: 1.007-1.020), respectively. In addition, our stratified analyses revealed that girls and children aged 1 to 6 years were more sensitive to PM exposure, and the PM-associated risks for AC were more apparent in autumn and winter. Our study suggests that short-term exposure to PMs may induce AC in children.
Collapse
|
85
|
Zwingelberg S, Li S, Doulis A, Simon M, Wawer Matos PA, Rokohl AC, Heindl LM. Novel preloaded monocanalicular silicone stent for nasolacrimal duct intubation. Br J Ophthalmol 2023; 107:302-303. [PMID: 36368773 DOI: 10.1136/bjo-2022-321948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 10/28/2022] [Indexed: 11/13/2022]
|
86
|
Hage A, Knoeri J, Leveziel L, Majoulet A, Buffault J, Labbé A, Baudouin C. [From ocular itching to eye rubbing: a review of the literature]. J Fr Ophtalmol 2023; 46:173-184. [PMID: 36635208 DOI: 10.1016/j.jfo.2022.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 09/20/2022] [Accepted: 09/22/2022] [Indexed: 01/11/2023]
Abstract
Ocular itching and eye rubbing are frequent complaints in an ophthalmology practice. Numerous studies address the consequences of eye rubbing, such as keratoconus. However, there are few studies concerning the pathophysiology of itching, its transmission pathways, or its interactions with eye rubbing. Through this literature review, we will address the various clinical, physiological and therapeutic aspects of this pair of symptoms with a variety of ocular consequences. We will then describe the state of the art in itching and scratching in dermatology, in order to draw a parallel between these two vicious cycles. A better understanding of the pathophysiology of ocular itching and eye rubbing, as well as new studies based on dermatological data, might allow more appropriate clinical management of our patients and their symptoms.
Collapse
|
87
|
Rousseau A, Vauloup-Fellous C, Haigh O, Pavy S, Molinari D, Jauréguiberry S, Angoulvant A, Labetoulle M. Conjunctival conveyance of SARS-CoV-2 in asymptomatic and non-severe symptomatic COVID-19 patients. J Fr Ophtalmol 2023; 46:101-105. [PMID: 36635207 PMCID: PMC9812824 DOI: 10.1016/j.jfo.2022.09.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 09/13/2022] [Indexed: 01/07/2023]
Abstract
INTRODUCTION The prevalence of ocular conveyance of SARS-CoV-2 has been well described for severe/hospitalized cases, but scarcely reported in asymptomatic and non-severe patients, who are unaware that they are carriers. MATERIAL & METHODS This prospective cross-sectional study quantitatively evaluated SARS-CoV-2 shedding on the ocular surface (OS). Conjunctival testing was suggested to all hospital personnel being screened by nasopharyngeal (NP) SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR). Disease symptoms were evaluated using a standardized questionnaire and telephone follow-up 6±3 months later for disease evolution (recovery with/without severe disease). RESULTS Four hundred and eighty seven patients were included. From 46 NP SARS-CoV-2-positive subjects (cycle threshold [CT]=24.2±7.1), 13% tested positive at the OS (CT=36.4±2.8). Most SARS-CoV-2-positive subjects were symptomatic (n=40, 87%), while 6 were asymptomatic (being tested as contact cases). Systemic symptoms were not significantly different in OS-positive vs OS-negative subjects, although headache tended to be more frequent in OS-positives (83% vs 54%, P=0.06). None of the OS-positive subjects reported ocular symptoms and none developed severe disease requiring hospitalization or oxygen therapy. CONCLUSION SARS-CoV-2 shedding at the OS may occur in asymptomatic and non-severe COVID-19 individuals (including those absent of ocular symptoms). However, the high RT-PCR CT values attained may indicate a low risk of transmissibility via this route.
Collapse
|
88
|
Lazreg S, Garout R, Boulanab F, Aberkane D, Djabour M, Boudedja H, Acheli A, Derdour A, Zine El Abidine N, Ghemri N. [ Ocular surface disease in glaucoma patients: Expert opinion and management algorithm in Algeria]. J Fr Ophtalmol 2023; 46:152-162. [PMID: 36642596 DOI: 10.1016/j.jfo.2022.07.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/23/2022] [Accepted: 07/25/2022] [Indexed: 01/15/2023]
Abstract
INTRODUCTION The main goal of treatment for any glaucoma patient is to reduce the intraocular pressure. Unfortunately, the long-term use of glaucoma medications causes deleterious effects on the ocular surface, leading to impaired quality of life and failed glaucoma surgery. In addition, adverse effects of medications are a barrier to adherence and compliance, and this directly affects efficacy. It is therefore essential to regularly assess the ocular surface of glaucoma patients in order to detect any signs of damage early and act accordingly. Although the TFOS DEWS 2 now offers a strategy for diagnosing ocular surface pathologies, some examinations are unfortunately not feasible in Algeria due to lack of time and/or knowledge on the part of some ophthalmologists or are simply inaccessible to others. METHODS Algerian experts (members of the ACOS club) met for the purpose of proposing an algorithm for the management of Algerian glaucoma patients, based on the recommendations of the DEWS, their own practice and the results of a preliminary national survey of ophthalmologists. RESULTS The proposed algorithm allows evaluation of the ocular surface of the glaucoma patient in current practice by any Algerian ophthalmologist. CONCLUSION Management of glaucoma patients should include a systematic examination of the ocular surface. The choice of treatment should be determined by the ocular surface condition of the glaucoma patient.
Collapse
|
89
|
Rojas-Carabali W, Mejía-Salgado G, Cifuentes-González C, Villabona-Martínez V, Barraquer-López ND, Valdés-Arias D, de-la-Torre A. Clinical relationship between dry eye disease and uveitis: a scoping review. J Ophthalmic Inflamm Infect 2023; 13:2. [PMID: 36715869 PMCID: PMC9886213 DOI: 10.1186/s12348-022-00323-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 12/26/2022] [Indexed: 01/31/2023] Open
Abstract
This scoping review examined the relationship between Dry Eye Disease (DED) and Uveitis. We searched Pubmed, Embase, and LILACS databases for articles in which at least one patient had DED and uveitis concomitantly. The search produced 2381 records, and 24 studies were included in the qualitative synthesis. We concluded that DED and uveitis of any etiology could appear concomitantly in patients of any age. However, both diseases seem to coexist more frequently in middle-aged women and cases of anterior uveitis. Therefore, it is crucial that ophthalmologists actively look for the coexistence of ocular surface abnormalities, especially in patients with these characteristics. Future studies should establish and quantify the risk factors and pathophysiological mechanisms of this coexistence to achieve an early diagnosis of both etiologies and comprehensive management of these patients.
Collapse
|
90
|
Chen Z, Xiang Z, Cui L, Qin X, Chen S, Jin H, Zou H. Significantly different results in the ocular surface microbiome detected by tear paper and conjunctival swab. BMC Microbiol 2023; 23:31. [PMID: 36707800 PMCID: PMC9883858 DOI: 10.1186/s12866-023-02775-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 01/16/2023] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND Great variation has been observed in the composition of the normal microbiota of the ocular surface, and therefore, in addition to differences in detection techniques, the method of collecting ocular surface specimens has a significant impact on the test results.The goal of this study is to ascertain whether the eye surface microbial communities detected by two different sampling methods are consistent and hence explore the feasibility of using tear test paper instead of conjunctival swabs to collect eye surface samples for microbial investigation. MATERIALS AND METHODS From July 15, 2021, to July 30, 2021, nonirritating tear test strips and conjunctival swabs of both eyes were used in 158 elderly people (> 60 years old) (79 diabetic and 79 nondiabetic adults) in Xinjing Community for high-throughput sequencing of the V3-V4 region of the 16S rRNA gene. The composition of the microbial communities in tear test paper and conjunctival swab samples was analyzed. RESULTS There was no statistically significant difference in Alpha diversity of ocular surface microorganisms represented by tear strip and conjunctival swab in diabetic group (P > 0.05), but there was statistically significant difference in Alpha diversity of ocular surface microorganisms detected by tear strip and conjunctival swab in nondiabetic group (P < 0.05). There were statistically significant differences in Beta diversity of ocular surface microorganisms detected by two sampling methods between diabetic group and nondiabetic group (P < 0.05). There were statistically significant differences in ocular surface microorganisms detected by tear strip method between diabetic group and nondiabetic group (P < 0.05), but there was no statistically significant difference in conjunctival swab method (P > 0.05). CONCLUSIONS Tear test paper and conjunctival swabs detect different compositions of microbes through two different techniques of eye surface microbe sampling. Tear test paper cannot completely replace conjunctival swab specimens for the study of microbes related to eye surface diseases.
Collapse
|
91
|
Gore A, Kadar T, Cohen M, Gutman H, Gez R, Dachir S, Horwitz V. The use of aflibercept (VEGF trap) in mitigating sulfur mustard-induced corneal neovascularization in a rabbit model. Toxicol Rep 2023; 10:206-215. [PMID: 36825253 PMCID: PMC9941054 DOI: 10.1016/j.toxrep.2023.01.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 01/24/2023] [Accepted: 01/25/2023] [Indexed: 01/29/2023] Open
Abstract
Sulfur mustard (SM)-induced ocular injury is characterized by an acute inflammatory response that may become chronic or enter a latent phase with delayed pathology. This study aimed to evaluate the efficacy of ziv-aflibercept and aflibercept in preventing and ameliorating corneal neovascularization (NV), respectively, following chemical eye exposure to SM vapor in a rabbit model. Chemical SM ocular insult was induced in the right eye of rabbits. A single application of ziv-aflibercept was administered 2 h or 9 days post-exposure. A single subconjunctival aflibercept treatment in an ocular formulation was administered 4 weeks after SM vapor exposure and subsequent to an initial 1-week treatment with 0.1 % dexamethasone. Clinical monitoring was performed 5-12 weeks post-exposure, and digital corneal pictures were taken to assess the extent of NV. The rabbits were euthanized and the corneas were processed for histological assessment. Treatment with ziv-aflibercept 2 h and 9 days post-exposure moderately reduced insult severity and partially delayed or prevented corneal NV. Aflibercept application 4 weeks post-exposure significantly reduced the extent of NV for 8 weeks. The substantial decrease in existing corneal NV in this group was confirmed by histology. These results reveal the powerful anti-angiogenic efficacy of the VEGF-trap for ameliorating existing NV as opposed to preventing NV development, revealing the ability of this treatment to mitigate corneal NV.
Collapse
|
92
|
Anatychuk L, Zadorozhnyy O, Naumenko V, Kobylianskyi R, Kustryn T, Nasinnyk I, Korol A, Pasyechnikova N. Device Development for Ocular Surface Temperature and Heat Flux Density Measurement. Curr Eye Res 2023; 48:441-446. [PMID: 36594458 DOI: 10.1080/02713683.2023.2165104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
PURPOSE Currently, much attention is paid to measuring the temperature of the ocular surface in various ophthalmic diseases. However, for a comprehensive assessment of heat transfer of the eye, it is advisable to measure both the ocular surface temperature and the heat flux (HF) density. This will expand our knowledge of the physiology of the eye and create new possibilities for diagnosing ocular pathology. The present study aimed to develop a thermoelectric device to study rabbits' ocular surface temperature and HF density. METHODS The multichannel thermoelectric device was developed to measure the ocular surface temperature and HF density. This study included ten rabbits (20 eyes). In all animals, the temperature and the HF density were measured on the surface of the central cornea of both eyes. The measurement was repeated after pupils' dilation. RESULTS The corneal surface temperature of rabbits was 33.1 ± 0.8 °C, and the HF density of the surface of the cornea was 8.3 ± 0.6 mW/cm2. Our results revealed a high degree of interocular symmetry in the surface HF density in healthy rabbits. After pupil dilation, an increase in the HF density on the surface of the rabbit cornea compared with the initial data and control eye was noted. CONCLUSIONS The application of the developed device showed that it is safe and allows for the measurement of the ocular surface temperature and the HF density. We believe that further studies on the ocular surface HF density measurement in various eye diseases will allow us to evaluate the possibilities of this device and technique for diagnostic purposes.
Collapse
|
93
|
Absence of detectable SARS-CoV-2 replication in ex vivo cultured cornea and cornea-derived epithelial cells. Graefes Arch Clin Exp Ophthalmol 2023; 261:435-446. [PMID: 35920896 PMCID: PMC9362677 DOI: 10.1007/s00417-022-05776-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 05/17/2022] [Accepted: 07/19/2022] [Indexed: 01/25/2023] Open
Abstract
PURPOSE To study the possibility of SARS-CoV-2 to infect human corneal cells and tissues under standard corneal culture conditions using explants of COVID-19 donors and primary cornea-derived epithelial cells. METHODS Cornea isolated from deceased COVID-19 donors was cultured for 4 weeks, and SARS-CoV-2 replication was monitored by qRT-PCR. Furthermore, primary corneal epithelial cells from healthy donors were cultured ex vivo and infected with SARS-CoV-2 and human cytomegalovirus (HCMV) as a control. Infection status was assessed by western blotting and reporter gene expression using green fluorescent protein-expressing viral strains. ACE2 and TMPRSS2 receptor expression levels in cornea and epithelial cells were assessed by qRT-PCR. RESULTS We did not detect SARS-CoV-2 replication in 10 corneas isolated from deceased COVID-19 patients and cultured for 4 weeks, indicating absence of infection under natural conditions. Furthermore, high-titer SARS-CoV-2 infection of ex vivo cultured cornea-derived epithelial cells did not result in productive virus replication. In contrast, the same cells were highly permissive for HCMV. This phenotype could potentially be explained by low ACE2 and TMPRSS2 transcriptional activity in cornea and cornea-derived epithelial cells. CONCLUSIONS Our data suggest that cornea and limbal epithelial cells are refractory to productive SARS-CoV-2 infection. This could be due to the absence of robust receptor expression levels necessary for viral entry. This study adds further evidence to support the very low possibility of transmission of SARS-CoV-2 from an infected corneal transplant donor to a recipient in corneal organ cultures.
Collapse
|
94
|
Xie J, Gao Q, Del Prado ZN, Venkateswaran N, Mousa HM, Salero E, Ye J, De Juan-Pardo EM, Sabater AL, Perez VL. Establishment of a bi-layered tissue engineered conjunctiva using a 3D-printed melt electrowritten poly-(ε-caprolactone) scaffold. Int Ophthalmol 2023; 43:215-232. [PMID: 35932420 PMCID: PMC9902434 DOI: 10.1007/s10792-022-02418-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 06/28/2022] [Indexed: 02/07/2023]
Abstract
PURPOSE To utilize melt electrowriting (MEW) technology using poly-(ε-caprolactone) (PCL) coupled with a 2-step co-culturing strategy for the development of a conjunctival bi-layer synthetic construct. METHODS Melt electrowritten scaffolds using PCL were fabricated using an in-house-built MEW printer. Human conjunctival stromal cells (CjSCs) and epithelial cells (CjECs) were isolated from donor tissue. A 2-step co-culture method was done by first seeding the CjSCs and culturing for 4 weeks to establish a stromal layer, followed by CjECs and co-culturing for 2 more weeks. Cultured cells were each characterized by morphology and marker expression on immunofluorescence and qPCR. The produced construct was assessed for cellular proliferation using viability assays. The bi-layer morphology was assessed using scanning electron microscopy (SEM), confocal microscopy, and immunofluorescence imaging. The expression of extracellular matrix components and TGF-b was evaluated using qPCR. RESULTS CjSCs were spindle-shaped and vimentin + while CjECs were polygonal and CK13 + . CjSCs showed consistent proliferation and optimal adherence with the scaffold at the 4-week culture mark. A 2-layered construct consisting of a CjSC-composed stromal layer and a CjEC-composed epithelial layer was appreciated on confocal microscopy, SEM, and immunofluorescence. CjSCs secreted collagens (types I, V, VI) but at differing amounts from natural tissue while TGF-b production was comparable. CONCLUSION The 3D-printed melt electrowritten PCL scaffold paired with the 2-step co-culturing conditions of the scaffold allowed for the first approximation of a bi-layered stromal and epithelial reconstruction of the conjunctiva that can potentially improve the therapeutic arsenal in ocular surface reconstruction.
Collapse
|
95
|
Urea and ocular surface: Synthesis, secretion and its role in tear film homeostasis. Ocul Surf 2023; 27:41-47. [PMID: 36375795 DOI: 10.1016/j.jtos.2022.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 11/13/2022]
Abstract
Urea has been detected in the tear film, aqueous humor, and vitreous of the eye. While most of the urea in the aqueous humor and vitreous is considered to be an ultrafiltrate from the blood vessels, the presence of urea transporters and urea-synthesizing enzymes in the lacrimal gland, meibomian glands, conjunctiva, and cornea suggests ureagenesis occurring at the ocular surface. This review summarizes the distribution and function of urea transporters, urea and its synthesizing enzymes at the ocular surface to analyze their role in the tear film homeostasis. Urea transporters (UT)-A- and UT-B-as well as the enzymes arginase I, II, and agmatinase are located at the ocular surface. Urea concentration on the ocular surface is influenced by blood urea concentration, the amount of urea released by the tear fluid, tear evaporation, and arginase concentration in the tears. There are conflicting reports on the relationship between tear and plasma urea levels though a linear correlation exists between their levels. Urea protects the ocular surface from osmotic stress and is thought to maintain a lipid-water interface in the lamellar phase of the tear film. The reduction of urea levels in the tears of patients with evaporative dry eye suggests its possible role in tear film stability. Other than mitigating osmotic stress, urea has hydrating properties as well. Animal studies have demonstrated the healing effects of urea on the corneal epithelium. Future studies examining the variations in urea content in tears from different ocular surfaces, at different times of day, and under different environmental conditions would further solidify the role of urea in tear film stability.
Collapse
|
96
|
Burgos-Blasco B, Arriola-Villalobos P, Fernandez-Vigo JI, Oribio-Quinto C, Ariño-Gutierrez M, Diaz-Valle D, Benitez-del-Castillo JM. Face mask use and effects on the ocular surface health: A comprehensive review. Ocul Surf 2023; 27:56-66. [PMID: 36577463 PMCID: PMC9789923 DOI: 10.1016/j.jtos.2022.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 12/12/2022] [Accepted: 12/21/2022] [Indexed: 12/26/2022]
Abstract
In the COVID-19 period, face masks increased exponentially. Several studies suggest that the rise in ocular discomfort symptoms during the pandemic is mostly part of dry eye disease and that these are due to the effect of face masks, resulting in the newly described term MADE, for "mask-associated dry eye". The most commonly proposed mechanism states that wearing a face mask creates an unnatural upward airflow towards the ocular surface during expiration, although the increased temperature, humidity and levels of carbon dioxide of the exhaled air, stress, increased use of video display terminals, as well as changes in the ocular microbiota may contribute. Evidence supports that the use of face masks causes an increase in dry eye disease symptoms, a decreased tear break-up time, corneal epithelial trauma, periocular temperature changes and inflammatory markers secretion. Given that the use of masks may be frequent in some settings in the near future, it is important to establish its effects and consequences on the ocular surface.
Collapse
|
97
|
Vicente García-Marqués J, Talens-Estarelles C, García-Lázaro S, Cerviño A. Assessment of condition-induced changes on the ocular surface using novel methods to assess the tear film dynamics and the lipid layer. Cont Lens Anterior Eye 2022; 46:101799. [PMID: 36577612 DOI: 10.1016/j.clae.2022.101799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 12/13/2022] [Accepted: 12/21/2022] [Indexed: 12/27/2022]
Abstract
OBJECTIVES To assess the effects of different condition-induced changes on current and novel ocular surface metrics. METHODS Eighty-four healthy volunteers (22.4 ± 2.6 years) participated in this study. The ocular surface and tear film response to (1) computer use, (2) contact lens insertion and (3) tear film instillation during computer use with contact lenses were assessed. Current metrics included the ocular surface disease (OSDI) questionnaire, 5-item dry eye questionnaire (DEQ-5), bulbar redness, tear meniscus height (TMH) and non-invasive keratograph break-up time (NIKBUT). Novel metrics included the lipid layer thickness obtained from the intensity of the reflected Placido disk and the speed of tear film particles post-blink. RESULTS Higher dry eye symptoms, TMH and bulbar redness, and lower values in metrics related to the intensity of the Placido disk pattern and to particle speed were found after the computer reading task (p < 0.036). When a contact lens was fitted, lower TMH, NIKBUT and particle speed metrics were obtained (p < 0.044). Mixed ANOVA revealed that artificial tears significantly ameliorated the effect of computer reading on OSDI, DEQ-5, NIKBUT, metrics related to the intensity of the Placido disk pattern and metrics related to particle speed (p < 0.033). CONCLUSIONS Computer use and contact lens wear worsened dry eye signs and symptoms, but artificial tears ameliorated this effect. Newly developed methods can serve as a tool to detect changes in the tear film triggered by different ocular surface-disturbing conditions.
Collapse
|
98
|
McHarg M, Wang Y, Yakin M, Zeleny A, Caplash S, Sen HN, Kodati S. Ocular symptoms in COVID-19 infection: a survey study. J Ophthalmic Inflamm Infect 2022; 12:42. [PMID: 36538113 PMCID: PMC9765365 DOI: 10.1186/s12348-022-00319-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 11/28/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Coronavirus disease 2019 (COVID-19) systemic symptoms and sequelae have been studied extensively, but less is known about the characterization, duration, and long-term sequelae of ocular symptoms associated with COVID-19 infection. The purpose of this study was to analyze the frequency, spectrum, and duration of ocular symptoms in participants with COVID-19 infection treated in inpatient and outpatient settings. METHODS A retrospective electronic survey was distributed to NIH employees and the public who reported testing positive for SARS-CoV-2. The anonymous survey collected information on demographics, past ocular history, systemic COVID-19 symptoms, and ocular symptoms. RESULTS A total of 229 (21.9% male and 78.1% female, mean age 42.5 ± 13.9) survey responses were included. Ocular symptoms were reported by 165 participants with a mean of 2.31 ± 2.42 symptoms. The most commonly reported ocular symptoms were light sensitivity (31.0%), itchy eyes (24.9%), tearing (24.9%), eye redness (24.5%), and eye pain (24.5%). Participants with ocular symptoms had a higher number of systemic symptoms compared to participants without ocular symptoms (mean 9.17 ± 4.19 vs 6.22 ± 3.63; OR: 1.21; 95% CI: 1.11 - 1.32; p < 0.001). Ocular symptoms were more common in those who reported a past ocular history compared to those who did not (81.8% vs 67.1%; OR: 2.17; 95% CI: 1.08 - 4.37; p = 0.03). Additionally, the onset of ocular symptoms occurred most frequently at the same time as systemic symptoms (47.5%), and 21.8% reported symptoms lasting ≥ 14 days. CONCLUSIONS Ocular surface-related symptoms are the most frequent ocular manifestations, and systemic disease severity is associated with the presence of ocular symptoms. Additionally, our results show that ocular symptoms can persist post-COVID-19 infection. Further work is needed to better understand ocular symptoms in COVID-19 and long-term sequelae.
Collapse
|
99
|
Magny R, Regazzetti A, Kessal K, Christin O, Baudouin C, Roulland E, Brignole-Baudouin F, Laprévote O, Auzeil N. Identification of new Omega-3 very long chain poly-unsaturated fatty acids in meibomian gland secretions. Biochimie 2022; 203:3-10. [PMID: 35476941 DOI: 10.1016/j.biochi.2022.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 03/14/2022] [Accepted: 04/19/2022] [Indexed: 12/16/2022]
Abstract
Three new very long chain polyunsaturated fatty acids (VLC PUFA) belonging to the omega-3 family have been identified in meibum samples collected by Schirmer strips. These VLC PUFA, namely FA (32:3), FA (34:3) and FA (36:3), were detected in O-acyl-ω-hydroxy fatty acids using a molecular network approach, and as free fatty acids. Identification was supported by retention time prediction model, exact mass determination and isotopic patterns. Double bond location was determined using cross metathesis reaction associated to tandem mass spectrometry. In meibum, synthesis of these VLC PUFA is likely to be mediated by elongation of very long chain fatty acids 4 enzyme. The biological role of these newly VLC PUFA and their occurrence in other tissues and biological fluids remains to be elucidated.
Collapse
|
100
|
Zhang Y, Qi Y, Xie X, Zhang F. The effect of 3% diquafosol on the improvement of ocular surface post cataract surgery: A meta-analysis for time of intervention. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH 2022; 2:100063. [PMID: 37846290 PMCID: PMC10577826 DOI: 10.1016/j.aopr.2022.100063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 05/02/2022] [Accepted: 05/09/2022] [Indexed: 10/18/2023]
Abstract
Purpose The effect of interventional time for 3% Diquafosol reatment in post-cataract surgery has not been well established. A meta-analysis was performed to evaluate the improvement of ocular surface condition in post-cataract surgery patients who received 3% DQS for various treatment durations. Methods Studies were performed based on 5 databases: PubMed, Cochrane Library, Web of Science, Embase, and China National Knowledge Infrastructure. Data on changes in Schirmer's test, tear breakup time (TBUT), corneal staining score, and OSDI score were collected for meta-analysis. Results A total of 621 affected eyes from 9 independent clinical studies were included. 6 studies conducted Schirmer's test after the application of 3% DQS. Meta-analysis showed that the difference between 3% DQS and control groups was not statistically significant for short-term application (less than or equal to 1 month) (WMD = 0.14, P = 0.27, 95% CI:-0.11 to 0.39), but was statistically different for long-term application (longer than or equal to 3 months) (WMD = 0.76, P = 0.03, 95% CI:0.08 to 1.45). For the corneal fluorescence staining score, the data from 6 studies indicated that the improvement was statistically significant for short-term application (WMD = -0.40, P <0.00001, 95% CI:-0.72 to -0.08) and but not long-term application (WMD = -0.21, P = 0.26, 95% CI:-0.57 to 0.15). For TBUT, the data from 9 studies indicated that both short-term and long-term application showed significant improvement (WMD = 1.70, P <0.00001, 95% CI:1.38 to 2.03; WMD = 1.52, P <0.00001, 95% CI:1.09 to 1.95). Similar results were observed in data from 5 studies with OSDI scores, where both short-term and long-term application showed statistically significant improvements (WMD = -5.41, P <0.00001, 95% CI: -7.02 to -3.81; WMD = -6.10, P <0.00001, 95% CI:-8.52 to -3.67). Conclusions The application of 3% DQS in post-operative cataract patients has a positive effect on improving the ocular surface conditions. Short-term application resulted in lower corneal staining scores, prolonged TBUT, and improved OSDI scores. Long-term application improved Schirmer's test results, TBUT, and subjective symptoms. Key messages The updated article suggests that 3% Diquafosol is less effective in the short term after cataract surgery, and that application over three months can improve the patient's ocular surface condition.
Collapse
|