76
|
Abstract
Infrared (IR) spectroscopic imaging seemingly matured as a technology in the mid-2000s, with commercially successful instrumentation and reports in numerous applications. Recent developments, however, have transformed our understanding of the recorded data, provided capability for new instrumentation, and greatly enhanced the ability to extract more useful information in less time. These developments are summarized here in three broad areas--data recording, interpretation of recorded data, and information extraction--and their critical review is employed to project emerging trends. Overall, the convergence of selected components from hardware, theory, algorithms, and applications is one trend. Instead of similar, general-purpose instrumentation, another trend is likely to be diverse and application-targeted designs of instrumentation driven by emerging component technologies. The recent renaissance in both fundamental science and instrumentation will likely spur investigations at the confluence of conventional spectroscopic analyses and optical physics for improved data interpretation. While chemometrics has dominated data processing, a trend will likely lie in the development of signal processing algorithms to optimally extract spectral and spatial information prior to conventional chemometric analyses. Finally, the sum of these recent advances is likely to provide unprecedented capability in measurement and scientific insight, which will present new opportunities for the applied spectroscopist.
Collapse
|
77
|
Chen K, Adato R, Altug H. Dual-band perfect absorber for multispectral plasmon-enhanced infrared spectroscopy. ACS NANO 2012; 6:7998-8006. [PMID: 22920565 DOI: 10.1021/nn3026468] [Citation(s) in RCA: 173] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Metamaterial-based perfect absorbers utilize intrinsic loss, with the aid of appropriate structural design, to achieve near unity absorption at a certain wavelength. For most of the reported absorbers, the absorption occurs only at a single wavelength where plasmon resonances are excited in the nanostructures. Here we introduce a dual-band perfect absorber based on a gold nanocross structure. Two bands of maximum absorption of 94% are experimentally accomplished by breaking the symmetry of the cross structure. Furthermore, we demonstrate the two bands can be readily tuned throughout the mid-infrared with their associated resonances giving rise to large near-field enhancements. These features are ideal for multiband surface-enhanced infrared spectroscopy applications. We experimentally demonstrate this application by simultaneously detecting two molecular vibrational modes of a 4 nm thick polymer film utilizing our proposed absorber. Furthermore, in response to variations in the interaction strength between the plasmonic and molecular dipoles, we observe an anticrossing behavior and modification in the spectral line shape of the molecular absorption peak, which are characteristic of the coupling between the two modes.
Collapse
|
78
|
Revin DG, Hassan RS, Krysa AB, Wang Y, Belyanin A, Kennedy K, Atkins CN, Cockburn JW. Spectroscopic study of transparency current in mid-infrared quantum cascade lasers. OPTICS EXPRESS 2012; 20:18925-18930. [PMID: 23038531 DOI: 10.1364/oe.20.018925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We report measurements which give direct insight into the origins of the transparency current for λ ~5 µm In0.6Ga0.4As/In0.42Al0.58As quantum cascade lasers in the temperature range of 80-280 K. The transparency current values have been found from broadband transmission measurements through the laser waveguides under sub-threshold operating conditions. Two active region designs were compared. The active region of the first laser is based on double-LO-phonon relaxation approach, while the second device has only one lower level, without specially designed resonant LO-phonon assisted depopulation. It is shown that transparency current contributes more than 70% to the magnitude of threshold current at high temperatures for both designs.
Collapse
|
79
|
Yashunsky V, Lirtsman V, Zilbershtein A, Bein A, Schwartz B, Aroeti B, Golosovsky M, Davidov D. Surface plasmon-based infrared spectroscopy for cell biosensing. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:081409-1. [PMID: 23224170 DOI: 10.1117/1.jbo.17.8.081409] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cell morphology is often used as a valuable indicator of the physical condition and general status of living cells. We demonstrate a noninvasive method for morphological characterization of adherent cells. We measure infrared reflectivity spectrum at oblique angle from living cells cultured on thin Au film, and utilize the unique properties of the confined infrared waves (i.e., surface plasmon and guided modes) traveling inside the cell layer. The propagation of these waves strongly depends on cell morphology and connectivity. By tracking the resonant wavelength and attenuation of the surface plasmon and guided modes we measure the kinetics of various cellular processes such as (i) cell attachment and spreading on different substrata, (ii) modulation of the outer cell membrane with chlorpromazine, and (iii) formation of intercellular junctions associated with progressive cell polarization. Our method enables monitoring of submicron variations in cell layer morphology in real-time, and in the label-free manner.
Collapse
|
80
|
Nugent-Glandorf L, Neely T, Adler F, Fleisher AJ, Cossel KC, Bjork B, Dinneen T, Ye J, Diddams SA. Mid-infrared virtually imaged phased array spectrometer for rapid and broadband trace gas detection. OPTICS LETTERS 2012; 37:3285-7. [PMID: 22859160 DOI: 10.1364/ol.37.003285] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We present and characterize a two-dimensional (2D) imaging spectrometer based on a virtually imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, we also demonstrate rapid, time-resolved single-image detection by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5×10(-4) are readily detected on the millisecond time scale, leading to important future applications such as real-time monitoring of trace gas concentrations and detection of reactive intermediates.
Collapse
|
81
|
Liberman V, Adato R, Jeys TH, Saar BG, Erramilli S, Altug H. Rational design and optimization of plasmonic nanoarrays for surface enhanced infrared spectroscopy. OPTICS EXPRESS 2012; 20:11953-67. [PMID: 22714181 PMCID: PMC3482914 DOI: 10.1364/oe.20.011953] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2012] [Revised: 04/30/2012] [Accepted: 05/03/2012] [Indexed: 05/30/2023]
Abstract
We present an approach for rational design and optimization of plasmonic arrays for ultrasensitive surface enhanced infrared absorption (SEIRA) spectroscopy of specific protein analytes. Motivated by our previous work that demonstrated sub-attomole detection of surface-bound silk fibroin [Proc. Natl. Acad. Sci. U.S.A. 106, 19227 (2009)], we introduce here a general framework that allows for the numerical optimization of metamaterial sensor designs in order to maximize the absorbance signal. A critical feature of our method is the explicit compensation for the perturbative effects of the analyte's refractive index which alters the resonance frequency and line-shape of the metamaterial response, thereby leading to spectral distortion in SEIRA signatures. As an example, we leverage our method to optimize the geometry of periodic arrays of plasmonic nanoparticles on both Si and CaF2 substrates. The optimal geometries result in a three-order of magnitude absorbance enhancement compared to an unstructured Au layer, with the CaF2 substrate offering an additional factor of three enhancement in absorbance over a traditional Si substrate. The latter improvement arises from increase of near-field intensity over the Au nanobar surface for the lower index substrate. Finally, we perform sensitivity analysis for our optimized arrays to predict the effects of fabrication imperfections. We find that <20% deviation from the optimized absorbance response is readily achievable over large areas with modern nanofabrication techniques.
Collapse
|
82
|
Zhu J, Mathes T, Stahl AD, Kennis JTM, Groot ML. Ultrafast mid-infrared spectroscopy by chirped pulse upconversion in 1800-1000cm(-1) region. OPTICS EXPRESS 2012; 20:10562-10571. [PMID: 22565682 DOI: 10.1364/oe.20.010562] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Broadband femtosecond mid-infrared pulses can be converted into the visible spectral region by chirped pulse upconversion. We report here the upconversion of pump probe transient signals in the frequency region below 1800cm(-1), using the nonlinear optical crystal AgGaGeS4, realizing an important expansion of the application range of this method. Experiments were demonstrated with a slab of GaAs, in which the upconverted signals cover a window of 120cm(-1), with 1.5cm(-1) resolution. In experiments on the BLUF photoreceptor Slr1694, signals below 1 milliOD were well resolved after baseline correction. Possibilities for further optimization of the method are discussed. We conclude that this method is an attractive alternative for the traditional MCT arrays used in most mid-infrared pump probe experiments.
Collapse
|
83
|
Kiguchi M, Atsumori H, Fukasaku I, Kumagai Y, Funane T, Maki A, Kasai Y, Ninomiya A. Note: wearable near-infrared spectroscopy imager for haired region. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:056101. [PMID: 22667665 DOI: 10.1063/1.4704456] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A wearable optical topography system was developed that is based on near-infrared spectroscopy (NIRS) for observing brain activity noninvasively including in regions covered by hair. An avalanche photo diode, high voltage dc-dc converter, and preamplifier were placed in an electrically shielded case to be safely mounted on the head. Rubber teeth and a glass rod were prepared to clear away hair and reach the scalp. These devices realized for the first time a wearable NIRS imager for any region of the cortex. The activity in the motor cortex during finger tapping was successfully observed.
Collapse
|
84
|
Boudreau S, Genest J. Referenced passive spectroscopy using dual frequency combs. OPTICS EXPRESS 2012; 20:7375-7387. [PMID: 22453417 DOI: 10.1364/oe.20.007375] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A referenced passive spectroscopy scheme using infrared frequency combs is presented. We perform a noise analysis and compare the results with a classical Fourier transform spectrometer. Experimental results are shown and great agreement with theory is obtained.
Collapse
|
85
|
Amrania H, Antonacci G, Chan CH, Drummond L, Otto WR, Wright NA, Phillips C. Digistain: a digital staining instrument for histopathology. OPTICS EXPRESS 2012; 20:7290-7299. [PMID: 22453410 DOI: 10.1364/oe.20.007290] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We describe a new mid-infrared (mid-IR) imaging method specifically designed to augment the H + E tissue staining protocol. Images are taken with bespoke IR filters at wavelengths that enable chemical maps to be generated, corresponding to the cytoplasmic (amide) and nuclear (phosphodiester) components of unstained oesophageal tissue sections. A suitably calibrated combination of these generates false colour computer images that reproduce not only the tissue morphology, but also accurate and quantitative distributions of the nuclear-to-cytoplasmic ratio throughout the tissue section. This parameter is a well documented marker of malignancy, and because the images can be taken and interpreted by clinically trained personnel in a few seconds, we believe this new "digistain" approach makes spectroscopic mid-IR imaging techniques available for the first time as a practical, specific and sensitive augmentation to standard clinical cancer diagnosis methods.
Collapse
|
86
|
Lanzarotta A, Marcott C, Story GM, Dowrey AE, Sommer AJ. Infrared microspectroscopy using prism-based spectrographs and focal plane array detection. APPLIED SPECTROSCOPY 2012; 66:304-311. [PMID: 22449308 DOI: 10.1366/11-06412] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Several prism-based spectrographs employing a mercury cadmium telluride (MCT) focal plane array detector have been interfaced to an infrared microscope. In the combined system, the area-defining aperture of the microscope also served as the entrance slit to the spectrograph. This investigation considered the fundamental limits of diffraction for both the spectrograph and microscope in order to determine both the spatial and spectral resolution of the system as a whole. Experimental results for spectral resolution, spectral range, and peak-to-peak noise have been presented. Finally, the dynamic capabilities of one spectrograph/microscope combination were investigated.
Collapse
|
87
|
Jung Y, Han B, Mostafid ME, Chiu P, Yazdani R, Imhoff PT. Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills. WASTE MANAGEMENT (NEW YORK, N.Y.) 2012; 32:297-304. [PMID: 21996285 DOI: 10.1016/j.wasman.2011.09.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2010] [Revised: 08/22/2011] [Accepted: 09/09/2011] [Indexed: 05/31/2023]
Abstract
Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF(6)), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.
Collapse
|
88
|
Miller AL, Drake PL, Murphy NC, Noll JD, Volkwein JC. Evaluating portable infrared spectrometers for measuring the silica content of coal dust. JOURNAL OF ENVIRONMENTAL MONITORING : JEM 2012; 14:48-55. [PMID: 22130611 PMCID: PMC4689602 DOI: 10.1039/c1em10678c] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Miners face a variety of respiratory hazards while on the job, including exposure to silica dust which can lead to silicosis, a potentially fatal lung disease. Currently, field-collected filter samples of silica are sent for laboratory analysis and the results take weeks to be reported. Since the mining workplace is constantly moving into new and often different geological strata with changing silica levels, more timely data on silica levels in mining workplaces could help reduce exposures. Improvements in infrared (IR) spectroscopy open the prospect for end-of-shift silica measurements at mine sites. Two field-portable IR spectrometers were evaluated for their ability to quantify the mass of silica on filter samples loaded with known amounts of either silica or silica-bearing coal dust (silica content ranging from 10-200 μg/filter). Analyses included a scheme to correct for the presence of kaolin, which is a confounder for IR analysis of silica. IR measurements of the samples were compared to parallel measurements derived using the laboratory-based U.S. Mine Safety and Health Administration P7 analytical method. Linear correlations between Fourier transform infrared (FTIR) and P7 data yielded slopes in the range of 0.90-0.97 with minimal bias. Data from a variable filter array spectrometer did not correlate as well, mainly due to poor wavelength resolution compared to the FTIR instrument. This work has shown that FTIR spectrometry has the potential to reasonably estimate the silica exposure of miners if employed in an end-of-shift method.
Collapse
|
89
|
Lekgoathi MDS, le Roux JP. Attenuated total reflectance powder cell for infrared analysis of hygroscopic samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2011; 82:529-531. [PMID: 21835688 DOI: 10.1016/j.saa.2011.07.062] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 07/14/2011] [Accepted: 07/18/2011] [Indexed: 05/31/2023]
Abstract
An attenuated total reflectance (ATR) sample cell has been designed, manufactured and subsequently used for the mid-infrared analysis of hygroscopic samples. This sample cell was installed as a simple drop-in replacement for the cell supplied with our commercially available Harrick Mvp-Pro FTIR-ATR accessory. Calcium chloride, a well-known desiccant that has a propensity to absorb water into its crystal lattice, was selected as non-infrared active substrate to accentuate the efficacy of the cell in preserving the anhydrous state of the sample by straightforward monitoring of the water bands. In contrast, mid-infrared spectra are presented that qualitatively demonstrate the rapid rate at which atmospheric moisture is incorporated into the anhydrous sample when analyzed using the conventional ATR cell assembly.
Collapse
|
90
|
Kokalj M, Kolar J, Trafela T, Kreft S. Differences among Epilobium and Hypericum species revealed by four IR spectroscopy modes: transmission, KBr tablet, diffuse reflectance and ATR. PHYTOCHEMICAL ANALYSIS : PCA 2011; 22:541-546. [PMID: 21465601 DOI: 10.1002/pca.1315] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 11/25/2010] [Accepted: 12/21/2010] [Indexed: 05/30/2023]
Abstract
INTRODUCTION Quality control of dried plant material in assessments of suitability of herbal medicinal products is of extreme importance. Commonly used procedures for identification of species are time consuming and expensive. The development of multivariate statistical methods has enabled application of vibrational spectroscopy for establishing plant species membership. OBJECTIVE To determine which infrared spectroscopy mode gives most informative spectra for plant species identification. METHODOLOGY Different modes of infrared spectroscopy were applied for investigation of differences among Epilobium and Hypericum species: diffuse reflectance (DR), attenuated total reflectance (ATR), direct transmission of whole leaves and KBr tablet transmission with comminuted leaves. The same chemometrical methods were applied to all spectra. The informative wave numbers were chosen by one-way analysis of variance. Afterwards the colinearity was reduced with principal component analysis. In the final step the species identification was determined with discriminant analysis. RESULTS Transmission and diffuse reflectance mode did not give satisfactory results. Best results for discrimination among Epilobium species were obtained with ATR mode (98%), while best results for Hypericum species were obtained with KBr transmission mode (97%). This might be explained by the morphological properties of the two genera. Epilobium species differ in distribution and morphology of trichomes on the surface of the leaves. Hypericum species differ in structures and secondary metabolites in the interior of the leaves. CONCLUSION For best results in using infrared spectroscopy for plant species identification in quality control, the morphological properties of plant material should be taken into consideration.
Collapse
|
91
|
Kakuta N, Fukuhara Y, Kondo K, Arimoto H, Yamada Y. Temperature imaging of water in a microchannel using thermal sensitivity of near-infrared absorption. LAB ON A CHIP 2011; 11:3479-3486. [PMID: 21869986 DOI: 10.1039/c1lc20261h] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This paper presents a remote and preparation-free method of temperature imaging of aqueous solutions in microchannels of microfluidic chips. The principle of this method is based on the temperature dependency of the near-infrared (NIR) absorption band (ν(2) + ν(3) band) of water. Temperature images were constructed from absorbances in a narrow wavelength range including 1908 nm, the most sensitive to temperature in the band, measured by using an NIR camera and an optical narrow-bandpass filter. Calculation and calibration results demonstrated a linear relationship between the absorption coefficient and temperature with a temperature coefficient of 1.5 × 10(-2) K(-1) mm(-1). Temperature images of 50 μm thick water in a Y-shaped PDMS microchannel locally heated by a neighboring hot wire were obtained, in which thermal diffusion processes in the microchip were visualized. Temperature resolution was estimated to be approximately 0.2 K according to the temperature coefficient and noise level.
Collapse
|
92
|
Bista RK, Bruch RF, Covington AM. Infrared spectroscopic study of thermotropic phase behavior of newly developed synthetic biopolymers. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2011; 81:583-589. [PMID: 21764360 DOI: 10.1016/j.saa.2011.06.055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Revised: 06/16/2011] [Accepted: 06/20/2011] [Indexed: 05/31/2023]
Abstract
The thermotropic phase behavior of a suite of newly developed self-forming synthetic biopolymers has been investigated by variable-temperature Fourier transform infrared (FT-IR) absorption spectroscopy. The temperature-induced infrared spectra of these artificial biopolymers (lipids) composed of 1,2-dimyristoyl-rac-glycerol-3-dodecaethylene glycol (GDM-12), 1,2-dioleoyl-rac-glycerol-3-dodecaethylene glycol (GDO-12) and 1,2-distearoyl-rac-glycerol-3-triicosaethylene glycol (GDS-23) in the spectral range of 4000-500 cm(-1) have been acquired by using a thin layered FT-IR spectrometer in conjunction with a custom built temperature-controlled demountable liquid cell having a pathlength of ∼15 μm. The lipids under consideration have long hydrophobic acyl chains and contain various units of hydrophilic polyethylene glycol (PEG) headgroups. In contrast to conventional phospholipids, this new kind of lipids forms liposomes or nanovesicles spontaneously upon hydration, without requiring external activation energy. We have found that the thermal stability of the PEGylated lipids differs greatly depending upon the acyl chain-lengths as well as the nature of the associated bonds and the number of PEG headgroup units. In particular, GDM-12 (saturated 14 hydrocarbon chains with 12 units of PEG headgroup) exhibits one sharp order-disorder phase transition over a temperature range increasing from 3°C to 5°C. Similarly, GDS-23 (saturated 18 hydrocarbon chains with 23 units of PEG headgroup) displays comparatively broad order-disorder phase transition profiles between temperature 17°C and 22°C. In contrast, GDO-12 (monounsaturated 18 hydrocarbon chains with 12 units of PEG headgroup) does not reveal any order-disorder transition phenomena demonstrating a highly disordered behavior for the entire temperature range. To confirm these observations, differential scanning calorimetry (DSC) was applied to the samples and revealed good agreement with the infrared spectroscopy results. Finally, the investigation of thermal properties of lipids is extremely critical for numerous purposes and the result obtained in this work may find application in various studies including the development of PEGylated lipid based novel drug and substances delivery vehicles.
Collapse
|
93
|
Funane T, Atsumori H, Kiguchi M, Tanikawa Y, Okada E. Optical scanning system for light-absorption measurement of deep biological tissue. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:093101. [PMID: 21974567 DOI: 10.1063/1.3632133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A noncontact near-infrared scanning system for multi-distance absorption measurement of deep biological tissue was developed. An 808-nm laser, whose focal point on the surface of biological tissue is controlled by a galvano scanner, is used as a light source. A phosphor is placed at a detection focal point on the tissue surface. The light that propagates through tissue and exits from the tissue surface beneath the phosphor excites the phosphor. The fluorescence emitted from the phosphor is detected by an avalanche photodiode. The system is used to measure 20 points on tissue surface at which source-detector (S-D) distances are 7-45 mm (with 2-mm intervals). Neither the light source nor the detector contacts the tissue surface. The system was validated by using it to measure the absorption change of an absorber (which is embedded in a deep layer of a tissue-simulating phantom) while the surface-layer thickness of the phantom was changed from 1 to 12 mm. It was demonstrated that both the relative absorption change of the absorber and the absolute thickness of the surface layer can be estimated from the measured optical-density change (ΔOD) and the dependence of ΔOD on S-D distance, respectively.
Collapse
|
94
|
Williams CL, Meir JU, Ponganis PJ. What triggers the aerobic dive limit? Patterns of muscle oxygen depletion during dives of emperor penguins. J Exp Biol 2011; 214:1802-12. [PMID: 21562166 PMCID: PMC3092726 DOI: 10.1242/jeb.052233] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2011] [Indexed: 11/20/2022]
Abstract
The physiological basis of the aerobic dive limit (ADL), the dive duration associated with the onset of post-dive blood lactate elevation, is hypothesized to be depletion of the muscle oxygen (O(2)) store. A dual wavelength near-infrared spectrophotometer was developed and used to measure myoglobin (Mb) O(2) saturation levels in the locomotory muscle during dives of emperor penguins (Aptenodytes forsteri). Two distinct patterns of muscle O(2) depletion were observed. Type A dives had a monotonic decline, and, in dives near the ADL, the muscle O(2) store was almost completely depleted. This pattern of Mb desaturation was consistent with lack of muscle blood flow and supports the hypothesis that the onset of post-dive blood lactate accumulation is secondary to muscle O(2) depletion during dives. The mean type A Mb desaturation rate allowed for calculation of a mean muscle O(2) consumption of 12.4 ml O(2) kg(-1) muscle min(-1), based on a Mb concentration of 6.4 g 100 g(-1) muscle. Type B desaturation patterns demonstrated a more gradual decline, often reaching a mid-dive plateau in Mb desaturation. This mid-dive plateau suggests maintenance of some muscle perfusion during these dives. At the end of type B dives, Mb desaturation rate increased and, in dives beyond the ADL, Mb saturation often reached near 0%. Thus, although different physiological strategies may be used during emperor penguin diving, both Mb desaturation patterns support the hypothesis that the onset of post-dive lactate accumulation is secondary to muscle O(2) store depletion.
Collapse
|
95
|
Moro S, Danicic A, Alic N, Usechak NG, Radic S. Widely-tunable parametric short-wave infrared transmitter for CO2 trace detection. OPTICS EXPRESS 2011; 19:8173-8178. [PMID: 21643067 DOI: 10.1364/oe.19.008173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
An all-fiber, tunable, short-wave infrared transmitter is demonstrated using efficient four-wave mixing in conventional L and O bands. To realize this source a highly-nonlinear fiber, exhibiting low bend loss over the short-wave infrared spectral band, is employed because of its advantageous properties as a nonlinear mixing medium. The transmitter was subsequently exploited to probe and detect trace levels of carbon dioxide in the 2051-nm spectral region where its beam properties, tunability, narrow linewidth, and stability all coalesce to permit this application. This work indicates this transmitter can serve as a robust source for sensing carbon dioxide and other trace gasses in the short-wave infrared spectral region and should therefore play an important role in future applications.
Collapse
|
96
|
Chirila MM, Lee T, Flemmer MM, Slaven JE, Harper M. Quantitative mid-infrared diffuse reflection of occupational wood dust exposures. APPLIED SPECTROSCOPY 2011; 65:243-249. [PMID: 21352643 DOI: 10.1366/10-06047] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Occupational exposure to airborne wood dust has been implicated in the development of several symptoms and diseases, including nasal carcinoma. However, the assessment of occupational wood dust exposure is usually performed by gravimetric analysis, which is non-specific. In this study, a mid-infrared (mid-IR) diffuse reflection method was adapted for direct on-filter determination of wood dust mass. The cup from the diffuse reflection unit was replaced with a horizontal translational stage and a filter with wood dust was set thereon. Diffuse reflection (DR) spectra were collected from filters with six different diameters in order to average the signal from the most filter surface. Two absorption bands around 1595 and 1510 cm(-1), attributed to lignin, were monitored for quantitative analysis. Calibration curves were constructed for standard extrathoracic red oak and yellow pine (aerodynamic particle diameters between 10 and 100 μm). Calibration of DR intensity versus known wood dust mass on the filter using the Kubelka-Munk function showed a nonlinear dependence for mass of less than 10 mg of wood dust. The experimental data and small-thickness samples indicate that Kubelka-Munk conditions are not obeyed. Alternatively, the pseudo-absorption function log(1/R), for which R is the relative reflectance, while still giving nonlinear dependence against mass, is closer to a linear dependence and has been preferred by other researchers. Therefore, we consider the use of the log(1/R) function for mid-infrared DR analysis of neat, small-thickness wood dust samples. Furthermore, we suggest the use of a silver metal membrane filter for direct on-filter analysis of wood dust rather than the glass fiber filters that have been used previously.
Collapse
|
97
|
Wysocki G, Weidmann D. Molecular dispersion spectroscopy for chemical sensing using chirped mid-infrared quantum cascade laser. OPTICS EXPRESS 2010; 18:26123-26140. [PMID: 21164961 DOI: 10.1364/oe.18.026123] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A spectroscopic method of molecular detection based on dispersion measurements using a frequency-chirped laser source is presented. An infrared quantum cascade laser emitting around 1912 cm(-1) is used as a tunable spectroscopic source to measure dispersion that occurs in the vicinity of molecular ro-vibrational transitions. The sample under study is a mixture of nitric oxide in dry nitrogen. Two experimental configurations based on a coherent detection scheme are investigated and discussed. The theoretical models, which describe the observed spectral signals, are developed and verified experimentally. The method is particularly relevant to optical sensing based on mid-infrared quantum cascade lasers as the high chirp rates available with those sources can significantly enhance the magnitude of the measured dispersion signals. The method relies on heterodyne beatnote frequency measurements and shows high immunity to variations in the optical power received by the photodetector.
Collapse
|
98
|
Gareau DS, Truffer F, Perry KA, Pham TH, Enestvedt CK, Dolan JP, Hunter JG, Jacques SL. Optical fiber probe spectroscopy for laparoscopic monitoring of tissue oxygenation during esophagectomies. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:061712. [PMID: 21198160 PMCID: PMC3000858 DOI: 10.1117/1.3512149] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2010] [Revised: 09/30/2010] [Accepted: 10/11/2010] [Indexed: 05/26/2023]
Abstract
Anastomotic complication is a major morbidity associated with esophagectomy. Gastric ischemia after conduit creation contributes to anastomotic complications, but a reliable method to assess oxygenation in the gastric conduit is lacking. We hypothesize that fiber optic spectroscopy can reliably assess conduit oxygenation, and that intraoperative gastric ischemia will correlate with the development of anastomotic complications. A simple optical fiber probe spectrometer is designed for nondestructive laparoscopic measurement of blood content and hemoglobin oxygen saturation in the stomach tissue microvasculature during human esophagectomies. In 22 patients, the probe measured the light transport in stomach tissue between two fibers spaced 3-mm apart (500- to 650-nm wavelength range). The stomach tissue site of measurement becomes the site of a gastroesophageal anastamosis following excision of the cancerous esophagus and surgical ligation of two of the three gastric arteries that provide blood perfusion to the anastamosis. Measurements are made at each of five steps throughout the surgery. The resting baseline saturation is 0.51±0.15 and decreases to 0.35±0.20 with ligation. Seven patients develop anastomotic complications, and a decreased saturation at either of the last two steps (completion of conduit and completion of anastamosis) is predictive of complication with a sensitivity of 0.71 when the specificity equaled 0.71.
Collapse
|
99
|
Sawosz P, Kacprzak M, Zolek N, Weigl W, Wojtkiewicz S, Maniewski R, Liebert A. Optical system based on time-gated, intensified charge-coupled device camera for brain imaging studies. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:066025. [PMID: 21198199 DOI: 10.1117/1.3523366] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
An imaging system for brain oxygenation based on a time-gated, intensified charge-coupled device camera was developed. It allows one to image diffusely reflected light from an investigated medium at defined time windows delayed with respect to the laser pulse. Applying a fast optomechanical switch to deliver the light at a wavelength of 780 nm to nine source fibers allowed one to acquire images in times as short as 4 s. Thus, the system can be applied in in vivo studies. The system was validated in phantom experiments, in which absorbing inclusions were localized at different depths and different lateral positions. Then, the decrease in absorption of the brain tissue related to increase in oxygenation was visualized in the motor cortex area during finger tapping by a healthy volunteer.
Collapse
|
100
|
Re R, Contini D, Caffini M, Cubeddu R, Spinelli L, Torricelli A. A compact time-resolved system for near infrared spectroscopy based on wavelength space multiplexing. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:113101. [PMID: 21133455 DOI: 10.1063/1.3495957] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We designed and developed a compact dual-wavelength and dual-channel time-resolved system for near-infrared spectroscopy studies of muscle and brain. The system employs pulsed diode lasers as sources, compact photomultipliers, and time-correlated single photon counting boards for detection. To exploit the full temporal and dynamic range of the acquisition technique, we implemented an approach based on wavelength space multiplexing: laser pulses at the two wavelengths are alternatively injected into the two channels by means of an optical 2×2 switch. In each detection line (i.e., in each temporal window), the distribution of photon time-of-flights at one wavelength is acquired. The proposed approach increases the signal-to-noise ratio and avoids wavelength cross-talk with respect to the typical approach based on time multiplexing. The instrument was characterized on tissue phantoms to assess its properties in terms of linearity, stability, noise, and reproducibility. Finally, it was successfully tested in preliminary in vivo measurements on muscle during standard cuff occlusion and on the brain during a motor cortex response due to hand movements.
Collapse
|